Efficient and sustainable insulation
2013 - 2014 Range
insulation
BIOMATERIAUX
www.biofib-insulation.com
(
(
Contents
Range of natural insulation systems •Productguide p. 4
•Technicalspecifications p. 6
•Associatedproducts: vapourbarrier,tapesandknife p. 16
Environment & energy management •Whychoosenaturalinsulationproducts? p. 18
•Biofib’ exclusive:acomplete"eco-logical"system p. 20
Efficient, durable insulation •Thermalcomfort p. 22
•Acousticcomfort p. 23
•Comfortableenvironment&hygrometry p. 24
•Convenientinstallation p. 25
Installation guide • solid WALLS
Liningwallsontheinside p. 28 Timber-framedHouse:insulationinsertedbetweenuprights p. 30
•Injectionintocavities p. 32
• ROOF & FLOORS Blowingbetweentrusses p. 33 Room-in-roof:insulationoftheslopesbetweenrafters p. 34 Coldatticspaces:insulationunrolledonthefloor p. 36 Floors&ceilings:insulationbetweenjoists p. 37
• INTERNAL PARTITIONS Loadbearing&separating p. 38
Packaging
p. 40
(
(
(
Improvingtheinsulationefficiencyofbuildings,whetherneworrefurbished,isamajorissueinthereductionofgreenhousegas emissions. Today, insulating your home should be anecological reflex action, beyond energy-saving concernsandmattersofcomfort.Indeed,theprotectionofourplanetrevolvesaroundtwomajor issues: thefightagainstclimatechangeandthereductionofour"fossil"resourceconsumption(oil,gas,minerals,etc.).
Reducing heating consumption by improving insulation isthereforeafirstecologicalaction.Choosinga"bio-sourced"insulation,which is efficientandnatural,made fromhempfibres,providesanadditional,specificresponsetoecologicalconcerns.
This is the gamblewearemakingwith theBiofib’rangeof"Eco-logical"insulationsystems!By controlling the entire production chain (growing hemp,defiberingandburling,packaginganddelivery to the site),Cavac Biomatériaux claims to be unique in combiningtechnicalefficiencywithsettinganecologicalexample:•A"hemp"cropthatisrenownedforitsecologicalvirtues.•A complete production chain: hemp and flax are grownbythefarmersinourcooperativeandprocessedinVendée(defiberingandburlingonthesamesite).
•Low embodied energy needs: observance of a true "shortcircuit"with cropsnear the industrial site, resulting in lesstransportationandaclearlypositivecarbonbalance!
•The quality of an industrial production that meets theexpectations of our partners and customers (quality,consistency,volume,traceability,prices,etc.).
Thesearea fewof thearguments thatback thepromiseofourBiofib’range:efficient, truly durable insulation!
Editorial
Olivier JoreauDirector of Cavac Biomatériaux
i n s u l a t i o n
www.biofib-insulation.com
4 5
Biofib’ isolation - Le Fief Chapitre - 85 400 Sainte Gemme la Plaine - Tél. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
hemp
100% hEmp insulationBiofib’ hemp is a natural, ecological insulation made by twisting hemp fibres. Available in the form of rolls or semi-rigid batts, it is mainly designed for thermal insulation.
100% natural CEllulosEJetfib’ouate is a thermal and acoustic insulation made of cellulose wadding from recycled newspapers.
Hemp 90% + binder Natural cellulose
Rlx : 30 kg/m3 - Pnx : 40 kg/m3 30 à 50 kg/m3
0,040 m2.K/W 0,040 (blowing) à 0,042 (injection)
blowing injection
45 / 60 / 80 / 100 / 200 mm -
100 mm -
- 10 kg bags
pg. 10 - 11 pg. 12 - 13
mix hEmp & flaxBiofib’ duo is an innovative mixture of hemp and flax fibres. Biofib’ duo batts and semi-rigid rolls are specially designed to provide “ecological” and “overall comfort” insulation for dwelling.
mix hEmp & CEllulosEBiofib’ ouate is an insulation composed of natural hemp and recycled cellulose fibres, all specially suited to thermal and acoustic insulation of residential and commercial buildings. It is packaged in the form of semi-rigid batts.
Composition Hemp 44% + Flax 44% + binder Hemp 25% + Cellulose 60% + binder
Density 30 kg/m3 45 kg/m3
Thermal conductivity (λ) 0,041 m2.K.W 0,040 m2.K.W
AppLiCAtions
Walls - Partitions
Room-in-roof
Loft/cold attic spaces
Floors
FoRmAt
Batts 45 / 60 / 100 / 120 / 140 / 160 / 200 mm 45 / 60 / 100 / 120 / 140 mm
Rolls 100 mm -
Loose - -
TECHNICAL SPECIFICATIONS pg. 6 - 7 pg. 8 - 9
produCt GuidE
Associatedproducts
Frenchtechnicalapproval
ACERMIcertification
Flex range BIOFIB’ (batts / rolls) Loose
Biofib’ controlVapourbarrier
Jetfib’ measuring gauge (Blowingincoldatticspaces)
Biofib’ adhesive tape •Yellow:forcoveringjoints •Green:airseal/junctions •Brown:double-sided
Handsaw insulation materials
50 mm
60
110
160
210
260
310
70
120
170
220
270
320
80
130
180
230
280
330
90
140
190
240
290
340
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
R=2
R=3
R=4
R=5
R=6
R=7
Really ecological solution for floor levelling
Biofib’ pellets (Biofib’ chape) pellet-based insulation boards are made of fine particles of plant matter derived from the separation of hemp and flax fibres which are then compacted in a high-pressure process without binder. A natural insulator, Biofib’ pellets is specially recommended for underfloor renovation work and for levelling floors that are irregular or in poor condition.
15 kg bags
The ecological virtues of hemp
Hempasacropisrespectfulwiththeenvironment:
•Itrequireslittlewaterandnopesticides
•ItabsorbsalargequantityofCO2duringits
growthcycle
•Itplaysaproductiveroleincroprotation
(biodiversity,soilregeneration)
pellets
EuropeanTechnical
Approval
ETA11-0005
TestReports
i n s u l a t i o n
www.biofib-insulation.com
Areas of application
(New & Renovation)
• Room-in-roof - installation between
and under rafters• Loft / cold attic space
unrolled on the ground
• Interior or exterior solid wall linings
• Separating walls
• Ceilings and floors unrolled on
the floor fitted between joists
(double layer)
The natural characteristics of the hemp mixture•Enhancedthermalefficiency•Naturalmoisturecontrol•Long,verystrongfibresthatproviderigidityand propermechanicalresistance.
•Doesnotattractrodents,containsnoproteins (nooccurrenceofmitesortermites)
•Willnotrot:doesnotdegradeovertime•Anatural,renewablerawmaterial•Recyclable
Designedusinganovelproductionprocessthatgivesthemalateral“springeffect”Biofib’ duoinsulationbattsdisplay:
•Excellent mechanical resistance, which helps make them easy to install andcontributestotheirlong-lastingefficiency
•Easy to cut and install, even on irregular surface (especially in renovations):cuttheinsulationwithanoverlapofapproximately2cminordercreateaslightpressure-fit
•Reduction of thermal bridges: the insulation “conforms” to the shape of theframe
•High stability over time: nosettling
•Maintains shape and positiononceinstalled:nospecialfixingsneeded
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
Advantages
Thicknesses / packagings
Biofib’ duo is an innovative mixture of hemp and flax fibres, the combination of which produces reinforced insulation. Biofib’ duo batts and semi-rigid rolls (thicknesses of 45 - 200 mm) are specially designed to provide "ecological" and "overall comfort" insulation for residences through high thermal efficiency.
Associated products
Batts: dimensions: 1.25 x 0.6 m (0.75 m2)
Thickness (mm)
Nb. sheets/
package
Surface area/package
(m2)
Nb. pack-ages /pallet
Surface area /pal-
let (m2)45 13 9,75 8 78
60 10 7,5 8 60
80 7 5,25 8 42
100 6 4,5 8 36
120 5 3,75 8 30
140 4 3 8 24
160 4 3 8 24
200 3 2,25 8 18
Rolls: Width: 0.6 m
Thickness (mm)
Length (m)
Surface area/roll (m2)
Nb. rolls/ pallet
Surface area/pallet (m2)
100 3.4 2.04 16 32.6
Biofib’ dual nosettling
duetogravity
Innovationlateralspringeffect,nothermalbridging
Technical SpecificationsComposition 44 % hemp fibres, 44 % flax fibres, synthetic binder
Density d (kg/m3) EN 1602 30
Thermal capacity Cp (J/kg.K) 1800
Thermal conductivity by weight λ (W/m.K) EN 12667 0.041 (ACERMI)
Thickness t (mm) EN 823 45 60 80 100 120 140 160 200
Thermal resistance R (m2.K/W) EN 12667 1,05 1,45 1,95 2,40 2,90 3,40 3,90 4,85
Thermal transmission cœfficient U (W/m2.K) 0.95 0.69 0.51 0.42 0,34 0,29 0.26 0,21
Water vapour diffusion resistance factor μ (mg/m2.h.Pa) EN 12086 ≤2
Water vapour transmission Sd (m) EN 12086 0.07 0.09 0.15 0.18 0.21 0.30
Airborne sound reduction Rw (dB)(C, Ctr) EN 140-3 > 56 (- 2 ; -7) Wood-frame wall / Biofib’ duo 140 mn / BA13 (vibration-mounted)
> 42 ( - 3 ; - 9) Partition 72/48 BA13 / Biofib’ duo 45 mn / BA13
Fire-performance Euroclass EN 13501-1 F
Max. temperature for use T (°C) 120 °C
mix hemp & flax
Andfinally,itsnatural,non-toxic,non-irritantandsoft-touchnaturalfibresrequirenospecialprecautionsduringinstallation.
Biofib’ controlVapourbarrier
Biofib' adhesive tape -forcoveringjoints -air-tight -double-sided
7
Long-lasting efficiencyAnatural,ecologicalinsulationproduct thatishealthyandnon-irritant
Enhancedthermalcomfort
Batts“springeffect”=easytoinstall
Moisturecontrol
FrenchTechnicalApprovalAT20/10-185
AT20/10-186
FrenchACERMI CertificationN°11/130/696
Épaisseur (mm) U =
45 0,9560 0,6980 0,51
100 0,42120 0,34140 0,29160 0,26200 0,21
Thermal transmission cœfficientU (W/m2.K)
Handsaw insulation materials
www.biofib-insulation.com
R en dB
C
20
30
40
50
60
70
80
90
f en Hz
10
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
0
20
40
60
80
100
f en Hz
100
125
160
200
250
315
400
500
630
800
1000
1250
1600
2000
2500
3150
4000
5000
Areas of application
(New & Renovation)
• Room-in-roof - installation between
and under rafters• Loft / cold attic space
unrolled on the ground
• Interior or exterior solid wall linings
• Separating walls
• Ceilings and floors
installation between joists
Hemp: a noble productHemp is a material renowned for itsecologicalpropertiesandisoneofthetypesofinsulationwiththelowestCO2 footprint:
• It requires little water and no pesticidesasacrop•It absorbs a large quantity of CO2
duringitsgrowthcycle•It makes good use of poor-quality
soils•It plays a productive role in
crop rotation (biodiversity, soilregeneration)
•Compared to mineral wools,plant-base insulations requirevery little energy to manufacture, whichhelpsreduce CO2 emissions.
•Biofib' insulations are produce by acompleteproductionprocess:
-from crop growing in the Vendéeregion(nearthemanufacturingsite)
-to the production of batts or rolls(fibre extraction and overlayingat the same site, meaning lesstransportation)
• Biofib' insulations display a very positive carbon balance, helping toachieve "double" energy savings and
protecttheearth.
Enhancedacousticcomfort
Batts“springeffect”=easytoinstall
Easytocut
Ecological,healthyandnon-irritantinsulationproduct
A complete « "Eco-Logical" production chain
The natural characteristics of the hemp/cellulose wadding mixture•Verystronghempfibresthatproviderigidityand propermechanicalresistance.
•Thetwofibrestructurescomplementeachotherforbetter acousticefficiency.
• Cellulosewadding:arecycledrawmaterial, derivedfromthere-useofunsoldorrecyclednewspapers.
•Qualitycontroloftherawmaterial (noglossypaper)
•Lowenergyconsumptioninproduction
•Recyclable
High acousticefficiency
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
Advantages
Thicknesses / packagings
Biofib’ ouate is an insulation composed of natural hemp and recycled cellulose fibres, all specially suited to thermal and acoustic insulation of residential and commercial buildings. It is packaged in the form of semi-rigid batts of 45, 60, 100 and 140 mm. Biofib’ ouate is mainly used for thermal and acoustic insulation of solid walls, roof structures and floors, whether newly built or under renovation.
Associated products
CO2
Batts: dimensions: 1.25 x 0.6 m (0.75 m2)
Thickness (mm)
Nb. sheets/pac kage
Surface area/package (m2)
Nb. packages /pallet
Surface area /pallet (m2)
45 13 9,75 8 78
60 10 7,5 8 60
100 6 4,5 8 36
120 5 3,75 8 30
140 4 3 8 24
Technical SpecificationsComposition 45 % hemp fibre, 45% cellulose, polyester binder
Density d (kg/m3) EN 1602 50
Thermal capacity Cp (J/kg.K) 1800
Thermal conductivity by weight λ (W/m.K) EN 12667 0.040
Thickness t (mm) EN 823 45 60 100 120 140
Thermal resistance R (m3.K/W) EN 12667 1,12 1,50 2,50 3,00 3,50
Thermal transmission cœfficient U (W/m2.K) 0,89 0,67 0,4 0,33 0,29
Water vapour diffusion resistance factor μ (mg/m2.h.Pa) EN 12086 ≤2
Water vapour transmission Sd (m) EN 12086 0.09 0.12 0.20 -
Airborne sound reduction Rw (dB)(C, Ctr) EN 140-3
> 61 (- 2 ; -7) Timber-frame wall / Biofib’ ouate 140 mn / Fermacell> 47 ( - 4 ; - 11) Partition 72/48 Fermacell / Biofib’ ouate 45 mn / Fermacell
> 69 ( - 2 ; - 7) Partition (double-skin) Fermacell / Biofib’ ouate 45+60+45 mn / Fermacell
Fire-performance Euroclass EN 13501-1 F
Max. temperature for use T (°C) 120 °C
mix hemp & cellulose
Timber-frame wall Basic partition Double partitionFacing Fermacell Fermacell
Rain-resistant Framing 48/35 Framing 48/35
OSB 19 mm Biofib’ ouate 45 mm Biofib’ ouate 45 mm
Framing 140 mm Biofib’ ouate 60 mm
Biofib’ ouate 140 mm Biofib’ ouate 45 mm
Vapour-resistant Framing 48/35
Framing 48/35 Fermacell
Fermacell Fermacell Fermacell
61 dB (- 2 ; - 7) 47 dB (- 4 ; - 11) 69 dB (- 2 ; - 7)
Thecombinationofhigh-densitycellulosewadding with hemp fibres providesBiofib’ ouate with excellent soundinsulation properties to give enhancedacoustic comfort. The measured and certified noise-reduction levels (FCBA tests) on standard walls are clearly superior to regulatory requirements.
Low-pitch sounds High-pitch soundsMid-range sounds
3
2
1
Biofib’ controlVapourbarrier
Biofib' adhesive tape -forcoveringjoints -air-tight -double-sided
Test
Reports
9
Rw(dB)
Handsaw insulation materials
www.biofib-insulation.com
Biofib’ dual nosettling
duetogravity
Innovationlateralspringeffect,nothermalbridging
Areas of application
(New & Renovation)
• Room-in-roof - installation between
and under rafters• Loft / cold attic space
unrolled on the ground
• Interior or exterior solid wall linings
• Separating walls
• Ceilings and floors unrolled on
the floor fitted between joists
(double layer)
Hemp: a noble productHemp is a material renowned for itsecologicalpropertiesandisoneofthetypesofinsulationwiththelowestCO2 footprint:
•It requires little water and no pesticidesasacrop.•It absorbs a large quantity of CO2
duringitsgrowthcycle.•It makes good use of poor-quality
soils•It plays a productive role in
crop rotation (biodiversity, soilregeneration)
•Compared to mineral wools,plant-base insulations require very little energy to manufacture, whichhelpsreduce CO2 emissions.
• Biofib' insulations are produce by acompleteproductionprocess:
-from crop growing in the Vendéeregion(nearthemanufacturingsite)
-to the production of batts or rolls(fibre extraction and overlayingat the same site, meaning lesstransportation)
• Biofib' insulations display a very positive carbon balance,helping toachieve "double" energy savings and
protecttheearth.
A complete « "Eco-logical"production chain
100% hemp natural insulation
The natural characteristics of hemp•Anatural,renewablerawmaterial
•Naturalmoisturecontrol
•Long,verystrongfibresthatproviderigidityand propermechanicalresistance.
•Willnotrot:nodegradationovertime
•Doesnotattractrodents,containsnoproteins (nooccurrenceofmitesortermites)
•Recyclable
Designedusinganovelproductionprocessthatgivesthemalateral"springeffect"Biofib' hempinsulationbattsdisplay:
•Excellent mechanical resistance, which helps make them easy to install andcontributestotheirlong-lastingefficiency
•Easy to cut and install, even on irregular surface (especially in renovations):cuttheinsulationwithanoverlapofapproximately2cminordercreateaslightpressure-fit
•Reduction of thermal bridges: the insulation "conforms" to the shape of theframe
•High stability over time: nosettling
•Maintains shape and positiononceinstalled:nospecialfixingsneeded
Long-lasting efficiency
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
Advantages
Thicknesses / packagings
Biofib’ hemp is a natural, ecological insulation made by overlaying hemp fibres. Available in the form of rolls or semi-rigid batts, it is mainly designed for thermal insulation of residential buildings (walls, roof structures and floors), whether newly built or under renovation.
Associated products
CO2
Andfinally,itsnatural,non-toxic,non-irritantandsoft-touchnaturalfibresrequirenospecialprecautionsduringinstallation.
Batts: dimensions: 1.25 x 0.6 m (0.75 m2)
Thickness (mm)
Nb. sheets/package
Surface area/package (m2)
Nb. packages /pallet
Surface area/pallet
(m2)
45 13 9,75 8 78
60 10 7,5 8 60
80 7 5,25 8 42
100 6 4,5 8 36
200 3 2,25 8 18
Rolls: dimensions: 3.4 x 0.6 m
Thickness (mm)
Surface area/roll(m2)
Nb. rolls/pallet Surface area/ pallet (m2)
100 2.04 16 32.6
Technical SpecificationsComposition 90% hemp fibre, polyester binder
Density d (kg/m3) EN 1602 40 (batts) / 30 (rolls)*
Thermal capacity Cp (J/kg.K) 1800
Thermal conductivity by weight λ (W/m.K) EN 12667 0,040
Thickness t (mm) EN 823 45 60 80 100 200
Thermal resistance R (m2.K/W) EN 12667 1.10 1.50 2.00 2.50 5
Thermal transmission cœfficient U (W/m2.K) 0.91 0.67 0.50 0.40 0,20
Water vapour diffusion resistance factor
μ(mg/m2.h.Pa) EN 12086 ≤2
Water vapour transmission Sd (m) EN 12086 0.09 0.12 0.16 0.20 0.28
Airborne sound reduction Rw (dB)(C, Ctr) EN 140-3 > 56 (- 2 ; -7) Timber-frame wall / Biofib’ hemp 140 mn / BA13
> 42 ( - 3 ; - 9) Partition 72/48 BA13 / Biofib’ hemp 45 mn / BA13
Fire-performance Euroclass EN 13501-1 F
Max. temperature for use T (°C) 120 °C
Biofib’ controlVapourbarrier Biofib' adhesive tape
-forcoveringjoints -air-tight -double-sided
EuropeanTechnical
Approval
ETA11-0005
11
hemphemp
Anatural,ecologicalinsulationproduct thatishealthyandnon-irritant
Durability:dimensionalstability andmechanicalresistanceovertime
Batts“springeffect”=easytoinstall
Moisturecontrol
*Rolls not concerned by ETA
Handsaw insulation materials
www.biofib-insulation.com
Domaines d’application
(Neuf & Rénovation)
ToITURE• Combles perdus (soufflage)
• Combles aménagés et
sous-face de plancher (insufflation)
MURs (insufflation)
• Doublage de murs par l’intérieur
• Cloisons distributives & séparatives
plAnChERs ET sols
• Entre solives (Epandage manuel)
100%recycledandrecyclable
Highinsulatingcapability
Thermalphaseshift
Humiditycontrol
Advantages
Specific qualities of Jetfib’ouate
Jetfib’ouate is a thermal and acoustic insulation made of cellulose wadding from recycled newspapers.It is applied by pouring, blowing, injection or projection. Jetfib’ouate is particularly recommended for insulating inaccessible, cold attic spaces.Its quick and efficient application means savings are made both in time and money.
RECYCLING FOR ECOLOGY
Cellulose wadding is an ecologicaland recyclable material made fromcarefully sorted recyclednewspapersorcutsofnewpaperfromtheprintingindustry.
In addition to its ecologicaladvantages, cellulose waddingprovidesexcellentthermalandphonicinsulation. Micro-organism resistantand rot-proof, it is open to watervapourdiffusion.
All these qualitiesmean that cellulosewadding is one of the best insulationmaterials in terms of ecological andtechnicalvalueformoney.
Compared with synthetic materials,cellulose wadding insulation requiresvery little energy for production andthushelpstoprotecttheenvironment.
Use of cellulose wadding thereforefully complieswith low environmentalimpact sustainable development byreducinggreenhousegasemissions.
CO2
• Thecellulosefibresaretreatedwithsodiumborateorammoniumphos-phate,whichhavebeenknownfortheirfungicidalandfireretardantproper-tiessinceancienttimes.
• ThesefeaturesmakeJetfib’anextremelyresistantinsulationthatdoesnotattractrodentsorinsectsandismould-resistant.Whenusedinyourhome,itthereforeprotectswoodenstructuresthatitcomesintocontactwith(walls,roofstructure,floors).
Technical specifications
13
Biofib’ isolation - Le Fief Chapitre - 85 400 Sainte Gemme la Plaine - Tél. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
Thicknesses / packagingBag (kg) No. bags/
palletWeight/pallet
(kg)No. pallets/
lorryWeight/lorry
(Tons)
10 40 400 26 10,4
Composition natural cellulose wadding
Density d (kg/m3) EN 1602 30 to 50 (varies according to application method)
Thermal capacity Cp (J/kg.K) 1900
Thermal conductivity by weight λ (W/m.K) EN 12667 0,040 (blowing) à 0,042 (injection)
Thickness applied (gauge) t (mm) EN 823 140 190 235 260 280
Thickness after settling (-15%) t (mm) EN 823 120 160 200 220 240
Thermal resistance R (m2.K/W) EN 12667 3 4 5 5,5 6
Water vapour diffusion resistance factor
μ(mg/m2.h.Pa) EN 12086 1
Permeability to water vapour Sd (m) EN 12086 0,12 0,16 0,20 0,22 0,24
Fire-performance Euroclasse EN 13501-1 B-s2d0 (t > 100 mm and d > 30 kg/m3 )
Max. temperature for use T (°C) 120 °C
Jetfib’ouateisappliedby:•manualpouring(betweenjoists),•blowing(inaccessible,unconvertedatticspaces),•injection(doublewalls,cavities),•projection(acousticflocking).
Itsapplicationbringsgreatsavingsbothintermsoftimeandmoney:•Quickandeasyapplicationinonelayer•nostorageorhandlingon-site•nocuttingorstripstojoin
Fibresizemeanseventhesmallestandhardesttoreachareasarefilled,providingop-timuminsulationwithoutthermalbreaksoruncontrolledsettling.
Application
94 mm118 mm
141 mm165 mm
188 mm212 mm
235 mm259 mm
282 mm306 mm
329 mm
0102030405060708090
100110120130140150160170
2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
50 mm
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
No. of bags (10 kg)for 100 m2
Thicknessto be applied
(2 pallets = 80 bags)
(1 pallet = 40 bags)
(4 pallets = 160 bags)
(3 pallets = 120 bags)
Thermalresistance (m2.K/W)
Number of 10 kg bags for 100 m2 (injection 50 kg/m3)
Number of 10 kg bags for 100 m2 (blowing 40 kg/m3)
Number of 10 kg bags for 100 m2 (blowing 30 kg/m3)
Jetfib’ measuring gaugeJetfib’ouatebagscomewithmeasuringgaugeswhichareusedasmarkersduringblowing(inatticspaces).
Thesegaugesenablethefibrestobeevenlydistributedwhileensuringtherequiredthicknessisapplied(graduationsincmandR-values).
50 mm60
110
160
210
260
310
70
120
170
220
270
320
80
130
180
230
280
330
90
140
190
240
290
340
100 mm
150 mm
200 mm
250 mm
300 mm
350 mm
400 mm
R=2
R=3
R=4
R=5
R=6
R=7
100% traditional wadding
www.biofib-insulation.com
•Easyfloorlevelling(nojoints, nocuts,fewoffcuts)
•Quickandeasyinstallation (nodryingtime)
•Possibilityofincludingelectricityandpipingducts
•Cleanworkingarea(dryspreading)
Floors: pay attention to the weight of the screed
Advantages
100 % plant-based insulation
Biofib’ pellets are made from fine particles of plant matter obtained by defibering hemp and flax, compacted without any binder. The natural Biofib’ pellets are specially recommended for renovation work and for levelling floors that are irregular or in poor condition. Its quick and easy installation (manual spreading) does not require water and does not raise any dust.
Associated products
Technical specificationsDiameter Ø (mm) 6
Length (mm) 10 to 25
On-site surface compaction (%) 1 to 2
Installation density (kg/m3) 700 +/- 50
Thermal conductivity λ (W/m.K) 0.060
Water vapour diffusion resistance μ (mg/m2.h.Pa) 1 - 2
Packaging (bag) (kg) 15
Environmental tolerance:
No emissions of CO2 or toxic fumes, hygrometric absorption and regulation capacity, odourless, electrostatically and electrically neutral, no harmful fibrous dust.
15
Hemp: a noble productHemp is a material renowned for itsecologicalpropertiesandisoneofthetypesofinsulationwiththelowestCO2 footprint:
• It requires little water and no pesticidesasacrop.•It absorbs a large quantity of CO2
duringitsgrowthcycle.•It makes good use of poor-quality
soils•It plays a productive role in
crop rotation (biodiversity, soilregeneration)
•Compared to mineral wools,plant-based insulation requires very little energy to manufacture, whichhelpsreduce CO2 emissions.
•Biofib' insulation is the result of acompleteproductionprocess:
-from crop growing in the Vendéeregion(nearthemanufacturingsite)
-to the production of batts or rolls(fibre extraction and overlayingat the same site, meaning lesstransportation)
• Biofib' insulations have a very positive carbon balance, helping to achieve "double" energy savings and
protecttheearth.
A complete "Eco-Logical" production chain
CO2
floor levelling
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
Support preparationToavoidtheriskofrisingdamp,extendapolyethylenefilm(min.thickness200μm)acrosstheentirefloorsurface,makingsurethestripsoverlapbyatleast20cm. Anyholesandcracksinthesupportmustbefilledintoavoidlosinggranules.Aplasticfilmcanalsobeplacedtohelpguaranteeagoodseal.Notsuitableforwetrooms.
Installing Biofib’ screedAfterremovingthedoors,alwaysstarttoinstallthedryscreedatthesideopposite theentrancetotheroom.•Emptythebagsbyhand(±7kg/m2/cmofthickness)andthendistributecrudelyusingarake.
•ThreerulesareusedwheninstallingBiofib’ screed:2guiderules and1draughtrule.
•Theguiderulesarearrangedinparallelontwobedsofgranules. Theflangesoftheserulesareonthesamelevelasthefinishedlevelofthedryscreed.Theircentredistanceissetaccordingtothelengthofthedraughtrule.
•Biofib’ screedisspreadoutbutnotpacked.Afterhavingdrawnaround50cm, theedgesarestraightenedusingatrowel,removingtheexcessgranules orcompletinganyshortages.
•Thescreedmusthaveathicknessofmorethan2cmandlessthan15cm onaverage(upto20cmlocally).Forthicknessesinexcessof10cm, itisadvisabletoinstalltwostackedlayers.
Finish•Oncethedryslabhasbeenmade,positiontheload-distributingbatts (OSB,chipboard)leavingaseparationof1cmfromtheperipheralwalls.
•Youcantheninstallthefloorcoveringofyourchoice.
Installation
100%hemp insulation
hempandflax-fibres
insulation
hemp&cellulosewadding
insulation
Biofib’ screedinsulatinggranulesdonotharmtheenvironmentandareentirelyrecyclable(ascompost,forexample).Theyaremadeupexclusivelyofplantmatter(hempandflaxfines),agglomeratedbycompression,withnobindersorchemicalpreservatives.
Before installing Biofib’ screed, please make sure the floor is capable ofwithstandingtheassociatedmechanicalload.
Screedthicknessincm
Screed
weig
htin
kg/m
2
pelletspellets
hemp
17
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
i n s u l a t i o n
www.biofib-insulation.com
Air-tightness & performance
The thermal and acoustic performance
of a building are closely interrelated
with the tightness of the insulated walls,
which depends on the Biofib’ control vapour
barrier, while allowing the materials to breathe
naturally.
Biofib' knife
The Biofib’ range of construction tapes is specially designed to cover all your needs when installing the Biofib’ control vapour barrier. Each tape is suited to a specific application: yellow tape for covering the strips, green tape for sticking the vapour barrier to all types of supports, brown "double-sided" tape for attaching Biofib’ control to the framework (timber or metal).
For quick and clean cutting of the batts and rolls of natural insulation products, use the Biofib’ knife (length 30 cm), which is supplied with its own sharpener. For working areas that require a large number of cuts, you can also use a disk knife equipped with a toothless disk (ø 115 to 230 mm).
16
Vapour barrier Adhesive tapes & knife
One tape for each specific application
Covering strips
Thisyellowsingle-sidedhighperformancetapeisspeciallyrecommendedforthewind-proofbondingofinsulationmaterialslikeroofmembranes.Itisused
mainlyforcoveringstripsandensuringtheair-tightnessoftheinsulation.
Joints of walls / floors / slopes…
Thisgreensingle-sidedhigh-performancetapeisdesignedforbondingindoorandoutdoorroofmembranesandbarriersintheconstructionindustry.
Itisparticularlysuitedforbondingwentandchimmeyareasandwind-proofmaskingofwindows,balksandpipediffusions.
sticking the vapour barrier to the uprights
This"double-sided"tapecanbeusedtostick theBiofib’ control vapourbarriertometaluprightsorwoodenframeworks.Itshighadhesivepoweralsomakesitveryusefulforotherapplicationsintheworkingarea.
TheBiofib’ control vapourbarrierisinstalledontheinsideofthedwelling.Itispositionedinthelastthirdoftheinsulation.
Biofib’ control:
• Canbecutusingscissorsoraknife.• Stapleddirectlytothewoodenframeworkorstuck tothemetaluprightsusingdouble-sidedadhesive (brown).
• Preferablyinstalledhorizontally,toreducethenumberofcutsandthenumberofjointsbetweenstrips(minimumoverlapof10cm).
• Sinceitdoesnotshrink,itcanbeinstalledfullystretchedoutwithnoriskoftearingorsagging.
Whiteandtranslucent,itprovidesenhancedvisibility, inparticularfortheconnectionsaswellasforgluingstripstooneanother.
Toensurecompleteair-tightnessandguarantee optimumthermalandacousticinsulation,specialcaremustbetakenwhenstickingthestrips:• totheuprights(staplesand/orbrowndouble-sidedadhesivetape)
• tooneanother,leavinganoverlapofatleast10cm(yellowadhesivetape)
• onthewall/floor/slope/ductcrossingjoints (greenadhesivetape,reinforced)
InstallationAdvantages
•Air-tightness:preventsseepage•Minimumwatervapourtransmission: avoidsrisksofcondensation
•Uniformdistributionofwatervapour: avoidsexcessmoistureintheframe
•Translucent:easierinstallation•Guaranteeofdurableinsulationandbreathingconstruction
Technical specifications
Colour white (translucent)
Dimensions (roll) 1.5 m x 50 m, or 75 m2
Grammage g/m2 85
Thickness µm 340
Tensile strength (MD/CD)
N/50 mm 120/90
Elongation (MD/CD)
% 90/100
Tear resistance (MD/CD)
N 59/63
Water vapour transmission
Sd (m) 1,8
Water column
EN 1928 W1
Fire performance
EN 11925-2 E
Dimensions (roll) 60 mm x 40 m linear
Composition and support Modified polyacrylate on special 120-µm paper
Adhesive weight g/m2 200
Thickness mm 0.32
Tack N/25 mm 38
Peel adhesion N/25 mm 40
Heat resistance °C 80
Dimensions (roll) 60 mm x 25 m linear
Composition and support Modified polyacrylate on 60-µm PE film
Adhesive weight g/m2 250
Thickness mm 0.32
Tack N/25 mm 33
Peel adhesion N/25 mm 40
Heat resistance SDgrC 80
Dimensions (roll) 30 mm x 25 m linear
Composition and support
Modified polyacrylate on PES/PVA film
Adhesive weight g/m2 230
Thickness mm 0.26
Tack N/25 mm 35
Peel adhesion N/25 mm 38
Heat resistance °C 100
rain screen
outside
inside
The Biofib’ control vapour barrier is a technical film made up of a non-woven fabric and a polypropylene membrane. Impervious to air and water, it prevents seepage and therefore reduces the risks of condensation forming inside the insulation (temperature < dew-point). Although not completely sealed against the vapour barrier (pervious in both directions), Biofib’ control plays an important role in natural moisture control in your home. It provides the perfect complement for Biofib’ insulation products.
Handsaw insulation materials
1918
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
i n s u l a t i o n
www.biofib-insulation.com
EnVironmEnt & energy management
crop harvest industrialunit
Why choose natural insulation products ? The active communication with the general public conducted by the ADEME highlights major issues relating to general energy savings, specifically in construction. In fact, the energy consumed in dwellings (residential and services) represents 43 % of total consumption, ahead of transport. Even more important than the collective efficiency of insulation is the choice of insulation.
TheaverageFrenchpersonemitsonaverage2.2tonnes/yearofcarbonequivalent,oraround7tonnesofCO2. Halfoftheseemissionscomefrompersonalenergyuse(transport,heatingandspecificelectricityindwellings,domestichotwaterconsumption,heating,lightingandcooking).Theconstructionsector(residentialandservices)aloneaccountsfor43%oftotalenergyconsumptioninFrance.Thereductionofgreenhousegasemissions isthereforecloselylinkedtoareductionofenergyconsumptioninbuildings.
Inthelastfewyearswehaveobservedhowusersare graduallyrealisingtheimportanceofsavingenergy, withbehaviouralchangesasakeyelement.Everyoneknowsthecommonsenserulesthatcanhelppreventenergywasteinourhomes(avoidingheatingrooms tomorethan19°C,switchingofflightswhenleaving aroom,etc).Butefficientlyinsulatingyourdwellingisalso,forobviousreasons,thefirstecologicalaction. Efficientinsulationcanrapidlyandsubstantiallyreduce ourenergyconsumptionandthereforereduceour greenhousegasemissions,withoutaffectingourlifestyles;quiteonthecontrary!Inordertobetrulyeffective,thisdevelopmentapproach mustbecollective.ThisisthemaingoalofFrenchthermalregulations(RT2005)andthenewstandardstobeapprovedintheconstructionsector,whichaimtoachieveconsiderablereductionsinenergyspending (Low-ConsumptionBuildings).Toreachthesetargets, itisimportanttochoose"efficient"insulation, withtechnicalspecificationscertifiedbyofficialbodies.
Inthisregard,Biofib’ insulation naturalinsulationsystemsmeetallthelatestdemandsofthermalregulations,withahighlevelofefficiency,renownedandvalidated(withCSTBandACERMItechnicalevaluationdocumentsinprogress).
Insulating your home is an economic choice Energysavingsinheatingwillalwaysresultinoverall "savings".Goodinsulationmeanscomfortandmoremoneyinyourpocket!Toprovidegreaterincentivesforcitizenstomaketherightchoicesfortheplanet,manyencouragingmeasureshavebeenimplementedinthecontextoftheGrenelle EnvironmentForum.Theeffectsoftheeconomiccrisishaveincluded reductionsintheamountofpublicaidofferedtosupport thedevelopmentof"ecological"productionchains(lower thresholdsfortaxcredits).However,thelatestfinancialactof2010retainsallthecoreprinciplesofthis"green"taxation.Quickoverviewofthevariousmeasuresthataimtoimproveenergymanagement(and/orencouragerenewableenergy):
•VATreduction(5.5%)forinstallationandthe guaranteeofimplementationbyaprofessional
•TaxdeductionforinterestonloansforpurchasingafirsthomethatcomplieswithBBCstandards(40%deductionfor7years)
•Allocationoftaxcredits(initiallyupto50%forsomematerials)
•Creationofenergyefficiencycertificateswiththeultimategoalofinfluencingthevalueofrealestateproperties.
•Eco-loanswith"zero"interestforpurchasesof ecologicaldevicesandmaterial
Aswecanseefromtherecentpopularityoforganic produceineverydaylife,consumersarebecoming moreandmoresensitivetoenvironmentalaspects andthe"natural"originoftheproductstheypurchase. Thistrendallowsustoexpectfavourablegrowth ofso-called"bio-sourced"insulationsystems, inparticularthosemadefrom"plant-based"fibres.Unlikemineralwoolswhichrequiretheuseoffossil fuels(forhowmuchlonger?),hempandflaxcrops, forexample,areperfectlyrenewable.Nottomention thathempdoesnotrequireanypesticides(orirrigation), offeringaproductionmodethatiscompletelyrespectful withtheenvironment.Inthisregard,peoplewhochooseTimber-framedhomes oftendosooutofacertaindesiretoliveina"natural"home,usingefficient,natural,healthymaterials.Giventheirspecificpropertiesintermsofhygrometryregulation,theBiofib’ hempandBiofib’ dualinsulationsystemsareperfectlysuitedtotheconceptof"breathingwalls"implementedin"Timber"houses.
There is only one step from natural to eco-friendly. But we still need to take it! Oneprerequisiteisfortherawmaterialstocome from"natural"sources.Furthermore,theecologicalimpactofproductsisoftenlinkedtothetypeofmanufacturingprocessandthevariousintermediatetransportation.Weoftenusetheterm"embodiedenergy"torefertotheamountof"carbonequivalent"requiredtosupplyandproduceinsulationsystems.Isitreallyeco-friendlytoobtainsuppliesfromtheothersideoftheplanetortooutsourceapartofproductionoverseas?Onceweallbecomeawareofourown"carbonfootprints",consumerswillthenbecometrueplayersandbeabletomakeeducatedchoicesofnatural,healthyandtruly "eco-logical"products.Insulationisobviouslyessentialinguaranteeingsavingsandcomfort.Environmentalawarenesswillallowustotake"eco-logics"toitsultimatestageandchooseinsulationsystemsthatcombineinsulationefficiencywhilesetting anecologicalexample.Consideringitsmanyadvantages(efficiency,naturality,complete,eco-friendlyprocess),theBiofib’ insulation rangeappearsasanefficient,durableinsulationsolutionthatisbothinnovativeandcompetitive.
Bio-sourced insulation: a plus for saving "fossil" resources
Insulating your home: a first step towards ecology! It is even better if you choose an efficient, truly Eco-Logical insulation system!
The ecological virtues
of hemp
Hempasacropisrespectfulwiththe
environment:
•Itrequireslittlewaterandnopesticides
•ItabsorbsalargequantityofCO2duringits
growthcycle
•Itmakesgooduseofpoor-qualitysoils
•Itplaysaproductiveroleincroprotation
(biodiversity,soilregeneration)
2120
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
i n s u l a t i o n
www.biofib-insulation.com
Hemp and flax cropsCO2 �xing during cultivation,
resulting in clearly positive carbon balance
Harvesting and delivery to the factoryHemp and �ax produced within a 100-km
radius around the industrial site
1st stage:defibering the straw
= “zero waste”
2nd stage:fibre burlingPlant �bre
(20 à 25 %)
FlaxMixture
Thermobonding
Mixingof �bres
Textile �bre (10 %)
Hemp
Shive (55 à 60 %)- hemp concrete- straw- litter
Dust (15 à 20 %)- litter- power
Recoveryof by-products
Shipping
Installation and efficientinsulation of the home
CO2 O2
defibering burling finishedproducts
EnVironmEnt & energy management
Cavac Biomatériaux exclusive: a complete "Eco-logical" system
In terms of natural insulation, Cavac Biomatériaux clearly stands out from the competition, relying on a true complete production system "from the field to the construction site". In fact, as part of the Cavac farming cooperative group, it manages all the hemp cultivation stages performed by the farmers in its territory so as to ensure industrial-quality production of Biofib’ insulation systems (defibering of straw and burling, packaging and delivery to construction sites).
The Biofib’ range of insulation systems claims to haveexemplary behaviour in ecological termsnotonlydue totheefficiencyofitsthermalinsulationmaterial,whichnaturallyresultsinenergysavings,butalsoduetotherawmaterialsituses,which are renewable and plant-based ("carbon sinks")and its "shortcircuit"productionmode (less transportation),producingaclearly positive carbon balance.
Involved in green businessFarming is a core element of Sustainable Developmentissues, given its strong connection to the land and theopportunitiesprovidedby"greengrowth":•Developmentofnewenergies(photovoltaic,biomass,etc.)•Improvement of innovative, renewablematerials as a truealternativetopetrochemicals
TheCavacGroup isa truedriving forcebehind thisprocess,withCavacBiomatériauxasagoodexampleofthisecologicalconsistency, for example with the construction of threestoragebuildingsequippedwithphotovoltaicbatts:6,000 m2 of roofs used to produce solar energy.
Industrial unit
22
www.biofib-insulation.com Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
23
thErmal Comfort
Key aspects of good thermal insulation
The efficiency of the insulating material Insulationprovides90%oftheinsulationofthewall.Ithelpsreduceheatlossandavoidscoldwalls,whichareasourceofdiscomfortandcondensation.
• Key Nb. 1: choosing insulation with low thermal conductivity and thickness adapted to the desired level of insulation. (e.g.: R = 5 for 200 mm of insulation with λ = 0.040).
The air-tightness of the frame Seepageofairfromtheoutsideisanothermajorsourceofheatlossandcanreducetheefficiencyofyourinsulationsystem(condensation).
• Key Nb. 2: installing a roof-boarding screen (or rain protection) that is pervious to water vapour on the outside (cold) and a vapour barrier such as Biofib‘control on the inside (hot).
Absence of thermal bridges Breaksofinsulation(jointsbetweenwalls,rafters,runners,etc.)aresomeofthe"cold" pointsthroughwhichheatcanpropagate.
• Key Nb. 3: to guarantee the continuity of the insulation by carefully sealing the joints of walls / floors / inner walls. To favour insulation in a staggered double layer.
Thermal inertia of the building Thegreaterthecapacityofthewallstostoreheat,theslowertheyheatandcool.
• Key Nb. 4: to be careful when choosing the structure (new buildings) and the density of the insulating materials.
A≤ 50
B51 to 90
C91 to 150
D151 to 230
E231 to 330
F331 to 450
G> 450
kWh/m2/ year
2,000,42
80
2,500,35
100
3,000,30
120
4,500,20
120+60
3,500,26
140
5,000,19
200
6,500,15
200+60
7,500,13
200+100
5,500,17
140+80
Thermaltransmissioncoe�cient U(W/m2.K)
WALLSROOF
0,30
0,35
0,40
0,45
0,25
0,20
0,15
0,45
0,40
0,35
0,30
0,15
0,20
0,25
insulation R (m2.K/W)
Wall U (W/m2.K)
22
λ - Thermal conductivity (W/m.K) Heat flow crossing amaterial thickness of 1m for atemperaturedifferenceof1ºCbetweenthetwosides.
The lower the value of λ, the greater the insulating properties of the material.
R - Thermal resistance (m2.K/W) Ability of amaterial to stop the transfer ofenergy.Itisproportionaltothethickness(e)andthethermalconductivity(λ),suchthat:R=e/λ.
The higher the value of R, the greater the insulating properties of the material.
U - Thermal transmission coefficient (W/m2.K) Ease with which thermal energypasses through the wall. It iscalculated by adding the inverseof the thermal resistance of thematerials that make up the wallandthesurfaceresistance.The lower the value of U, the greater the insulating properties of the wall.
thickness(mm)
20 cm 10 cm 1 cm
Gradient de température dans une paroi isolée
20°C
15°C
10°C
5°C
0°C
-5°C
-10°C
20°C
15°C
10°C
5°C
0°C
-5°C
-10°C
Rse = 0,04R Concrete wall = 0,20
R Insulation = 2,50R Facing = 0,05
Rsi = 0,13RT (m2.K/W) = 2,92
19°C
-4,5°C
80automobile
70road traffic
60conversation
50country-
side
40silence
90restaurant
100car horn
110concert
120air-
plane
dB
Key aspects of good acoustic insulation
Biofibʼ
Still air
transmittedsound
20 cm
10 cm
Sound Characterisedby:•its level = given as dB, this corresponds toacousticpressure.
•itsfrequency:givenasHz,thiscorrespondstothenumberofvibrationspersecond.
Itallowsustotellbetweenlow-pitchedandhigh-pitchedsounds.
Decibel (dB) Unit of measurement that expressesthe level of noise. It is expressed ona non-linear scale which has thepeculiaritythatthe sound level is multiplied by two every 3 dB.(e.g.:60dB+60dB=63dB)
Rw (C; Ctr) ExpressedindB,thisdescribestheinsulationofawall:•againstoutdoorairbornesound: Rw+Ctr(roadnoise)
•againstindoorairbornesound:Rw+C(pinknoise)
Air-tightness Soundgoeswhereveraircango:underdoors,throughwindowjoints,airvents,rollerblindboxesandthroughthewallitselfifnotproperlysealed.Goodacousticinsulationimpliesgoodair-tightness.
• Key Nb. 1: seal carefully to ensure a perfect seal! Place the vapour barrier making sure to correctly cover and joint the strips. Use resilient strips around the edges or else seal with putty.
Acoustic attenuation Inordertoprotectagainstnoisefromoutsidethedwelling,itisessentialtoprovidegoodinsulationagainstairbornesound.
• Key Nb. 2: favour the use of double walls including absorbent material and inner walls with high surface density (brick,gypsum, Fermacell).
Acoustical bridges Theuprightsofawoodenframework,runners,cabletroughsorwaterductsaresomeoftheacousticalbridgesthatcanfacilitatethepropagationofsound.
• Key Nb. 3: remember to detach the wall from its f inish facing. It is also advisable to avoid positioning the connection points opposite one other (min. 20 cm).
Acoustic correction / sound trapsMainlyusedinoffices,restaurantsandcinemas,itreducesthesoundlevelbytrappingthenoiseandpreventingphenomenaofsoundreverberation.
• Key Nb. 4: use absorbent surfaces such as curtains, carpets or an acoustic plenum made up of an absorbent insulation product placed behind a facing drilled on the inner side (in the wall or ceiling).
aCoustiC Comfort
WithBiofibInsulation (λ=0.040)
Top floor
Absorbed sound
24
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected] www.biofib-insulation.com
Associated products
ComfortablE EnVironmEnt ConVEniEnt installation
TocutandinstallyourBiofib’naturalinsulation(battsorrolls)withthebestconditions,werecommendthefollowingaccessories:
Thetechnicalcharacteristicsdefinedusingconventionalmethodsforeachinsulationsystem(λ,acousticefficiency,etc)areimportantandusefulwhenchoosingyourinsulation.Inaddition,thequalityofinstallationisalsoakeyfactorforactuallyobtainingthesameefficiency"onsite"(watchoutforthermalbridges!).
Thus,ease of installationandthecapabilityoftheinsulationtoadapttooftenrestrictiveinstallationconfigurationsguaranteethattheinsulation,onceinstalledinthewall,willremaineffectiveovertime.
Inordertomeetthisexpectationandprovidespecificsolutionsforarchitects, theBiofib’ insulation rangeincludesanexclusive,innovativeindustrialprocessassociatedwiththespringeffectofnaturalfibres.
Biofib’insulatingbattshaveveryhighmechanicalstrengthwhichcontributestotheireaseofinstallationandhelpsconservetheireffectivenessovertime byensuringperfectcontactbetweenuprightswithnothermalbridges.
• Rigidity: excellent mechanical strength (batts),anindicatorofstabilityovertime
• Durability: long-lasting efficiency (nosaggingcausedbygravity)
• Simplicity:nocutting"towithinmillimetres",evenwhendealingwithirregularstructuresorframeworks(refurbishment)
• Effectiveness:reductionofthermalbridges(matchestheshapeoftheuprights)
TheinstallationofBiofib’insulationsystems doesnotrequireanyspecificprecautions tobetaken.
Advantages of Biofib'insulation
Biofib’ controlVapourregulator50mx1.5mwide
=75m2/roll
Biofib' adhesive tapeAdhesives(green,yellow,doublesided):25or40mlinearx60mm
25
Hygrometry and quality of your indoor environment Management of environmental hygrometry isveryimportantinhomes.• Overly dry air is not healthy for the skin, mucousmembranesandairways.
• Overly humid air is also unhealthy, as wellas affecting the useful life of your home(condensation, deterioration of finishes andinsulationefficiency).
Hygrometrydescribestheamountofhumidityintheambientair,inotherwords,theamountofwatervapourcontainedintheair,givenasa%(oringramsofwater/m3ofdryair).The colder the air, the less water it can contain in the form of vapour (risk ofcondensation).
Sd = µ x eThe resistance to water vapour diffusion of amaterial is given in metres and relates to thethickness of the equivalent air space. It canbe described by Sd or µd. The product of µ isobtained according to the thickness of thematerialinmetres.
Sealed or breathing home? There are two opinions:
"Spring" effect: a Cavac Biomatériaux exclusive
Sealed homes to manage energy expenditure Thisconsistsofstoppingtheheatproducedinthehousefromescapingthroughthewallsbyanymeans,withuncontrolledairrenewalorthepermeabilityoftheframe.Thisveryoftenleadstotheconstructionofasealedhome,whichisparadoxicallyopposedtotheprincipleofnaturalhygrometryregulation.
Thisissometimesnecessaryinordertoprotectlow-densitymaterialsthataresensitivetopressurevariations(whichmayaffecttheirtechnicalspecificationsandincreasetheriskofcondensation).Inthiscase,itishighlyadvisabletoinstallanair-tightvapourbarrier.
"Double-flow"ventilationisalsorecommendedinordertoreduceenergylosstotheoutside.
Breathing homes to promote natural regulation of the homeInthiscase,thebreathingwallsenable thediffusionofexcessvapour(insidethebuilding)totheoutsideinauniformmannerandwithnodeterioration.Thematerialsthatformthewallsmustthenhavearelativelylowcoefficientofresistancetothetransmissionofwatervapour.
Itisthereforeadvisabletopositionthematerialsinorderofmosttoleastresistancetothetransferofwatervapour,fromtheinsidetotheoutside.• Thevapourbarrierhelpsincrease theresistanceoftheinnersurface
• Therainprotectionorroof-boardingscreen,placedontheoutside,mustbehighlypervioustowatervapour
rain screen
hygrometry
TheBiofib’ rangeofinsulationsystemsaddressesallconcernsregardinghygrometryregulation.Thanks totheirlowresistancetowatervapourdiffusion(µ<=2),theynaturallycontributetomaintaining ahealthy,balancedenvironmentinyourhome.InstallingtheBiofib’ controlvapourbarrier(perviousinbothdirections),usingBiofib’adhesivesforperfectair-tightness,isanadditionaladvantagethatallowstheinsulatedwallto"breathe".
Kitchen WC Living room - BedroomsFreshair
Polluted air:•moisture•dust•grease•CO2
Tip Coatings made from lime
and hemp (hemp chaff) are
especially recommended
for indoor finishes, not only
for their decorative value,
but also for their ability to
promote regulation of indoor
hygrometry.
Biofib’ insulationnoverticalsettling
Innovationlateralspringeffect, nothermalbridging
24
outside
inside
Handsaw insulation materials
26
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected] www.biofib-insulation.com
(
(
(
installation GuidE
Biofib’insulation :essential installation rules
Storetherollsandbattsintheiroriginalpackaging,protectedfromrainanddirectsunlight.
Cuttheinsulationtotherequiredwidthbetweensupports,withanexcessof2cm,andplacetheinsulationundergentlecompression("springeffect")toensureperfectcontactwiththeuprights.
Toensurecontinuousinsulation,takespecialcarewhensealingthejointsbetweenwalls (wall/floor/slope)andcheckingthatthestripsareinperfectcontact.
Ensurethemaximumsealoftheinsulationbyinstallinganoffset,continuousvapourbarrieronthe inside(hot)andaroof-boardingscreenthatispervioustowatervapourontheoutside(cold).
Installafinishingfacingwithmaximalfirerating(mandatory).
SOLID WALLS •Liningwallsontheinside p. 28
•Timber-framedhouse: p. 30 insulationinsertedbetweenuprights
•Injectionintocavities p. 32
ROOF, ROOF SPACES & FLOORS •Blowingbetweentrusses p. 33
•Room-in-roofspaces: p. 34 insulationoftheslopesbetweenrafters
•Loft/coldatticspaces:insulationunrolledonthefloor p. 36
•Floors&ceilings:insulationbetweenjoists p. 37
INNER PARTITIONS •Loadbearing p. 38
•Separating p.39
1
2
3
4
5
27
wall roof partition
Contents
i n s u l a t i o n
29
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
i n s u l a t i o n
28
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected] www.biofib-insulation.com
The wall is faced with stone, brick, concrete blocks or poured concrete.
Insulation consists of lining the inner surface of the wall by applying batts (or rolls) between the vertical uprights that provide a support for the finishing facing).
Continuous insulation with a stone-lined facing is also possible.
Lining walls on the inside
solid walls
Prior operations to be performed when working with old walls
Inrefurbishmentwork,makesurethattheouterfaçadeisingoodcondition,sinceitwillbeprovidingtheair-andwater-tightnessofthewall,anessentialconditionforguaranteeingdurablethermalinsulation.
If this is not the case, you will have to either: •Applyaninnercoatingfromthegroundtotheceiling•Installarainscreenontheinside,whichispervious
towatervapour.•Applyingarigidpanel(tongued-and-groovedOSB)overtheentireinner
surface. Thesurfacereceivingtheinsulationmustbecleananddry.
Installing the framing
Thethicknessoftheuprightsandcrossbeamsdependsonthethicknessoftheinsulationtobeinstalled.Thesecanbe:
•Attacheddirectlytothewalltobeinsulated(woodensleepers)•Offsettoavoidthermalandacousticalbridges(metalframework) Foroptimuminsulation,preferablyusestaggereddoublelayer
insulation(e.g.:60+60cm).Mechanicallyattachthemetalframeworkthatwillsupporttheinteriorfinishingfacing(gypsumboard,Fermacell, OSB,etc.).
Cutting the insulation
•Cuttheinsulationatthecentredistanceoftheuprightsincreasedby 2cmusingaBiofib’knifeoracircularsawprovidedwithatoothlessmaterialdisk(ø115to230mm).
•Thethicknessofthechoseninsulationwilldependonthedesiredthermalefficiency(U=0.33=>120mmforalambdaof0.040)aswellasthedepthoftheuprights.
1
2
3
Biofib’ insulation
Biofib’control
Upright
Interiorfinish
Installing the insulation
•Placetheinsulationbetweentheuprightsandcompressitgentlyinthedirectionofitswidthinordertomaximisethe"springeffect". Theinsulationimmediatelyreturnstoitsinitialshape,perfectlymatchingtheuprightsandthusavoidingtherisksofthermalbridges.
NB.:theinsulationcanbeglueddirectlyusinggypsumplastermortar totheinnersurfaceoftheouterwalls.
•Adjustthestripsofinsulationtoensuretheyarecompletelybutt-jointed. •Makesuretheinsulationiscontinuousatthejointsbetweenthewall,
floor,ceilingandslope.Ifneedbe,completeitwith"off-cuts" ofinsulationproducedonsite.
Vapour barrier
•AttachtheBiofib’ controlvapourbarriertotheuprights(double-sidedadhesive),continuouslyovertheentiresurface.
•Makesurethestripsoverlapbyatleast50mm. •Gluethestripstogetherandcheckthetightnessofthevapourbarrier
aroundalltheedgesofthewall(specificBiofib’adhesiveorputty).
Finishing facing
ItiscompulsorytoinstallafinishingfacingwithM1firerating.•Attachthefacing,gypsumboard,OSBor"M1"boardsbyscrewingthem
totheuprights.•Anoffsetlinedfacing(withclaytiles,forexample)canalsobeused,in
accordancewiththemanufacturer'srecommendations.
4
5
6
Tip: 100% natural interior finish, with a
"lime / hemp" coating.
• Lime / hemp coatings are renowned for
the many advantages they offer in terms of
decoration, acoustic comfort and hygrometry
regulation. For this reason, they perfectly
complement the Biofib’isolation natural
insulation systems.
31
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
i n s u l a t i o n
30
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected] www.biofib-insulation.com
solid wallsInsulation inserted between uprights DTU 31-2
Timber-framed house
This is known as "built-in" insulation since the Biofib’ batts are placed between the wooden uprights in one (or two) layer(s).
When placing a double layer with "staggered joints", it is necessary to place, perpendicular to the supporting uprights, a row of cleats, with their depth depending on the thickness of the second layer of insulation.
Cutting the insulation •Cuttheinsulationatthecentredistanceoftheuprightsincreased
by2cmusingaBiofibknifeoracircularsawprovidedwithatoothless materialdisk(ø115to230mm).
•Thethicknessofthechoseninsulationwilldependonthechoosedthermalefficiency(U=0.29=>140mmforalambdaof0.040)aswellasthedepth oftheuprights.
Installing the insulation between the uprights
•Placetheinsulationbetweentheuprightsandcompressitgentlyinthedirectionofitswidthinordertomaximisethe"springeffect".Theinsulation returnstoitsinitialshape,perfectlymatchingtheuprightsandthusavoidingtherisksofthermalbridges.
•Leaveaventilatedairspaceofatleast1cmbetweentheinsulationandtheouterfacingintheeventofusingaframeworkwithbuilt-inrainprotection.
•Adjustthestripsofinsulationtoensuretheyarecompletelybutt-jointed.
•Makesuretheinsulationiscontinuousatthejointsbetweenthewall,floor,ceilingandslope.Ifneedbe,completeitwith"off-cuts"ofinsulationproducedonsite.
Optional installation of a second layer (with staggered joints)
•Screwhorizontalcleats(minimumwidthof50mm,depthequaltothat ofthesecondlayerofinsulation,centredistanceof580mm)ontothe verticaluprights.
•Inserttheinsulation(600mm)betweenthecleats,compressingitgently(springeffect).
•Adjustthestripsofinsulationtoensuretheyarecompletelybutt-jointedandmakesuretheinsulationiscontinuousatthejointsbetweenthewallfloor,ceilingandslope.
1
2
3
Biofib’ insulation
Biofib’control
Interiorfinish
Vapour barrier •AttachtheBiofib’ controlvapourregulatorontheheatedside
ofthebuilding,bystaplingornailingittotheuprightsoftheprimaryframeworkortothecleatsofthesecondaryframework.
•Makesureeachstripoverlapstheothersbyatleast50mm.
•Checkthesealusingasuitableadhesiveinaccordancewith DTU31.2and41.2.
•Playverycloseattentiontothesealofthejointsbetweenstrips, wall/ceiling,wall/floor,inthecorners,intheconnectionswithopeningsandatallsingularplaces(chimneys,pipes,vents).
Interior finishing facing •Performtheinstallationofgypsumboardonasecondaryframework.
•Intheeventofattachinggypsumboardsdirectlytotheuprights oftheprimaryframework.
•Ineverycase,consultthecurrentregulationsinforceandthe recommendationsofthemanufacturers.
Special points: Junctions with door and window frames
•Thepurposeistoguaranteethecontinuityoftheinsulationtotheedgesofthedoorandwindowframesinordertoavoidtherisk ofcondensation.
•Thedoorandwindowframesmustbeequippedwithinsulationshutterssuitableforthethicknessoftheplannedinsulation.
4
6
3332
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected] www.biofib-insulation.com
Injection is used to insulate walls, partitions or intermediate floors. The walls to be insulated are made up of closed cavities that will keep the insulation in place. They are pierced at the top, in the centre of each cavity, to enable the injection pipe to pass through. Filling is performed from bottom to top while observing the density.Jetfib’ouate is packaged in 10 kg bags (40 bags per pallet): 2 pallets are required to insulate with approx. 180 mm thickness over 100 m2 (corresponding to a R>4).
Prior to application (essential) •Createawaterproofcasingforthewalltobeinsulated.Thisisgenerally
madefromOSB-typeplanksofwood.Itcanalsobecreatedusingthevapourbarrierontheinside(heated)andtheroofunderlay(roof)ortherainscreen(walls)ontheoutside.Inthiscase,makesurethatthenumberoffasteningpoints(stapling,againstbattens,etc.)isincreasedandcheckvapourbarrierresistance(reinforcedstructure).
•Usingaretractableknifeorholecutter,makeseveralholesatthetopofthecasingtoenabletheinjectionpipetopassthroughandairtoescape(vents)asfillingtakesplace.
Preparing the site •Positionthemachineascloseaspossibletotheareasconcerned,inthe
middleoftheroomforexample.
•Setthemachinetoachievearesultcorrespondingtotherequirements(density:approx.30to40kg/m3).
•TheoperatorlocatedinfrontofthemachinefeedsitbyopeningtheJetfib’ouatebagsandregularlypouringthemintotheinjectionmachine.
Applying the insulation •Inserttheinjectionpipeandfeeditthroughuntilitis±20cmfromthe
bottomofthecasing
•Graduallyfilleachcavitybypullingupthepipe.Makesurethatthereisaconstantandsufficientrateduringinjection.Donotwaitforastopinflowtopullupthepipe.
•Thecavityiscompletelyfilledwhentheproductoverflowsfromtheholesbeingusedasventsanditnolongercirculatesinthepipe(theinjectionmachineenginestopsautomatically).
•Carefullysealtheholes(vapourbarrier,adhesive,sealant).
Siding •UseofplasterboardonasecondaryframeisthesubjectofstandardDTU
25.41whichmustbeconsulted.
•Ifthecavitydoesnotfeaturearigidwallservingasasiding,mountaplasterboardorOSB-typesidingbyscrewingittotheuprights.
1
2
3
4
roof
Blowing is used to insulate cold or inaccessible attic spaces (e.g.: prefabricated roof structure made of industrial trusses). Insulation application involves blowing Jetfib’ cellulose wadding on the floor or suspended ceiling between the tie-beams.Jetfib’ouate is packaged in 10 kg bags (40 bags per pallet): 2 pallets are required to insulate with 240 mm thickness over 100 m2 (corresponding to R>5).
Prior to application (essential) •Makesurethatthefloororsuspendedceilingisingoodconditionand
iscapableofsupportingtheweightoftheinsulation,thattherearenoholesoropenventsandthattherearenotracesofdampcausedbywaterinfiltrationoraproblemwithroofwatertightness.
•Intheeventofunprotectedelectricalequipmentwhichcouldbeasourceofheat(suchasspotlightsortransformers),itisessentialtoprotectthemfromanycontactwiththeinsulationusingadequatemeans,seestandardNFC15-100.
•Electricandventilationductsarealreadyinplace.FindthedistributionboxesorTVaerialsintheatticspace.Theymustbelocatedoutsideoftheareawheretheinsulationistobeapplied.
Preparing for blowing •Positionmeasuringgaugesevery5metres.Theywillbeusedasmarkers
duringblowing.Circulateontrussesonly.
•Preparetheentrancetotheatticbybuildingaframearoundthetrapdoorwithaminimumheightequaltothatoftheinsulationtobeblown.
•Positionthemachineascloseaspossibletotheatticentranceandinsertthepipethroughthetrapdoororbetweenthebattensbycarefullyremovingafewtiles.Arrangethepipeintheatticsothattherearenobends.
•Setthemachineaccordingtotherequirements(density:approx.21to25kg/m3).
Applying the insulation •Theoperatorlocatedinfrontofthemachinefeedsitbyopening
theJetfib’ouatebagsandregularlypouringthemintotheblowingmachine.
•Thepersonlocatedintheatticbeginsblowingintheareasfurthestaway,workinghiswaybackgraduallytotheexit.
•Theblowingnozzleisheldhorizontally1metreabovethegroundsothattheinsulationfallswithitsownweight.
•Thecellulosewaddingisevenlydistributeduntilthedesiredthicknessisobtained(measuringgaugesorchalkmarksontheroofstructure).
In the event of a highly ventilated attic areaTopreventthewaddingfrommoving,spraywatermistabovetheinsulationtoobtainasurfacecrustwhendry.
1
2
3
walls and roofs Injecting wadding Cold attic spacesInjection into cavities Blowing between trusses
3534
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
i n s u l a t i o n
www.biofib-insulation.com
The roof spaces consists of a conventional framework made up of angled rafters and horizontal purlins. The installation will consist of placing a first layer of insulation between rafters, completed with a second layer perpendicularly staggered in order to comply with regulatory demands (R ≥ 5 m2.K/W).
roofInsulation of the slopes between rafters
Room-in-roof
Prior operations
•Itishighlyadvisabletoinstallavapourregulatingroof-boardingscreenontheoutside(cold)andanoffsetvapourbarrierontheinside(warm).
•Makesurethatthesurfacetobeinsulatedisclean,undamaged, freefromwaterandthattheroofdoesnothaveanyleaks.
•Acontinuousairgapof20mmmustbeleftbetweenthetopoftheinsulationandtheroofsupport(cleat).
Installing the framing Ifthefinishisagypsumboardonametalframework:
•Screwtherunnersontotherafterswiththehelpofamason'sline toensuretheyarealigned.
•Adjusttheirlengthtobeequaltothetotalthicknessoftheinsulation tobeinstalled+20mm(airspace).
•Screwsillstotheedgesinordertosupportthemetalfurring ateitherend.
Installing the insulation (between rafters)
•Thethicknessoftheinsulationmustbesimilartothethickness oftherafters.
•Measuretheseparationbetweenraftersandthencutthestrips ofinsulation,increasingthiswidthby2cminordertoensuretheirsupport.
•Placetheinsulationbetweentherafterswithgentlecompression. Theinsulationreturnstoitsinitialshape,maintainingperfectcontactwiththestructureandthusavoidingtherisksofthermalbridges.
•Takecaretoensurethecontinuityoftheinsulationandperfect sealingofthejointsbetweentheslope/floor/gables/purlins/ridge.
1
2
3
Interiorfinish
Purlins
Biofib’ insulation
Tip:
Use the off-cuts to insulate the spaces
between the peripheral rafters (first and last)
and the wall.
For installation in two staggered layers
•Screwhorizontalsleeperstotheraftersoftheslope(min.width 50mm,thickness(depth)equaltothatofthesecondinsulationlayer, separationof580mm).
•Inserttheinsulation(width600mm)betweenthesleepers, gentlycompressingit(springeffect)andstrivingtoensure thecontinuityoftheinsulationandperfectsealingattheends oftheslope,nexttothejointwiththefloor,thegables, thepurlinsandtheridge.
Vapour barrier •AttachBiofib’ controlontheheatedsideoftheroombystapling
ittothewoodenbattensorrafters.
•Makesurethateachstripoverlapstheothersbyatleast50mmand thatthewholeissealedusingsuitableadhesives.
•Payspecialattentiontothesealofthejointsbetweenslopes/walls/floorsandspecialpoints.
Finishing facing •Screwthefacingtothepreviouslyinstalledmetalframework.
4
5
6
Biofib’control
3736
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected] www.biofib-insulation.com
roofInsulation unrolled on the floor
The roof space, which consists of a conventional framework, is ventilated, unfinished and unheated. Installation will simply consist of unrolling the insulation on the floor or between joists and completing the insulation with a second layer staggered perpendicularly if necessary.
Tip:In the event of installation with staggered
joints, in order to avoid walking on and
damaging the first layer of insulation, use a
barge board on which you can walk.
Prior operations
•Installationgenerallyrequirestheplacementofavapourbarrier.
•Thevolumeoftheunconvertedroofspacemustbecorrectlyventilated.
Cutting the insulation Theinsulationthicknesswilldependontherequiredthermalefficiency.
•Forinstallationbetweenjoists,cuttheinsulationadding2cmtothewidth ofthestripstoensureexcellentcontactwiththeadjoiningwalls.
•Tosavetime,therollcanalsobecuttothedesiredwidthdirectly initspackaging.
Installing the insulation
•Simplyunrolltheinsulationonthefloor,takingcarenottoleaveany gapatthejointsbetweenthefloorandthewallsorroof- boardingslopes.
•Adjustthestripsofinsulationtoensuretheyarecompletelybutt-jointed.
•Makesurenogapareleftatthejointsbetweenthefloor andthewallsorroofslopestoavoidthermalbridges.
If necessary (recommended for optimum insulation) •Unrollasecondlayerofinsulationperpendiculartothefirstlayer,with
staggeredjoints,followingthesamerecommendationsasprovidedabove.
Theinsulationmustnotblockventilationopeningsandmustnottouchhotsources(chimneyflues,lights,etc.),withaminimumfireseparationof20cm.Inthesecases,useanon-combustibleinsulation(M0).
1
2
3
floors & CEilinGs
An intermediate floor, with a light structure made up of wooden joists, separates two volumes, at least one of which is heated. The insulation will consist of filling the spaces between joists with semi-rigid insulation (rolls or batts) or manually deposited fibres.
Tip:To complete the insulation against impact noise,
an acoustic layer made from flax or PE foam with
a thickness of 3-4 mm may be added once the
insulation has been made and before installing the
final floor.
Prior operations
•Makesurethatthesurfacetobeinsulatedisclean,ingoodconditionandcapableofwithstandingtheweightoftheinsulation(especiallyraisedfloors).
•Allmovementsacrossthesurfacemustbecarriedoutbywalking onthejoists. Forgreatersafety,itishighlyadvisabletosetupwalkwaysmadeup ofwoodenplanksrestingonseveraljoists.
Installing the insulation in rolls or batts
•Measuretheseparationbetweenjoistsandthecutthestrips ofinsulationincreasingthiswidthby2cminordertoensureexcellentcontactbetweenthejoists.
•Placetheinsulationbetweenthejoists,compressingitgently (springeffect).
•Makesurethatthestripsofinsulationareproperlybutt-jointedandthatthejointsbetweenthefloorandthewallsorroofslopesarecorrectlyinsulatedtoavoidtheriskofthermalandacousticalbridges.
•Air-tightnessisessentialforguaranteeingperfectthermalandacousticinsulation.
•Ifthetworoomsareheated,placeavapourbarrierabovetheinsulation.
Installing the facings Twofacingsarerequiredinthisconfiguration.Theyaremostcommonly
madeupof:
•Asuspendedceilingmadefromgypsumboardsonametalframework (orpanelling)ontheunderside.
•ConventionalflooringstripsnailedtothejoistsofsheetsofOSBcoveredwithfloatingparquetflooring,gluedorclippedtothetopthereof.
1
2
3
Biofib’ insulation
Biofib’control
Floors
FloorsBiofib’ insulation
Interior finish
Biofib’control
Cold attic spaces
3938
Cavac Biomateriaux - Le Fief Chapitre - F 85 400 Sainte Gemme la Plaine - Tel. 33(0)2 51 30 98 38 - Fax 33(0)2 51 30 98 37 - [email protected]
i n s u l a t i o n
www.biofib-insulation.com
The light building walls are made up mainly of a metal framework, covered with a facing (wood, gypsum, Fermacell, etc.) on either side. Distributive partitions (used for distributing the rooms within the same dwelling) are differentiated from separating partitions (for separating two dwellings). The difference between the two is found in the associated thermal and acoustic requirements.
innEr partitionsInsulation between uprights
Metal framework
•Drawthelocationoftherailsonthefloor,takingintoaccountthethicknessofthebattsandthelocationofthedoorandwindowframes.
•Mechanicallyattachtherailstothefloorevery50cm(screw+dowel ornail-screws).
•Transferthelayouttotheceilingusingaplumblineandmechanicallyattachthetoprailstotheceiling.
•Cuttheuprightstotheheightfromfloortoceiling,reducedby5mm.Positionthemevery40or60cm(optionallystapledorcrimpedontherails).
Attaching gypsum boards (on one side only)
•Cutthegypsumboardstotheceilingheightminus2cmsothatthefacingisnotrestingonthefloor(protectionagainstupwardleaching).
•Positionthefacingsbutt-jointedontheuprights(onwedges,supportedontheceiling).Screwthem(max.centredistanceof30cm)ontoonlyonesideofthepartitionsuchastostiffenthestructureandleaveonesideopenforinsertingtheinsulation.
Installing the Biofib’ insulation (batts or rolls)
•Forstandardpartitions(72/48)useBiofib’insulationwithathicknessof45mminrollsorinbatts.
•Measuretheseparationbetweenuprightsandthecutthestrips ofinsulationincreasingthiswidthby2cminordertoensureexcellentcontactbetweentheinsulationandtheuprights.
•Placetheinsulationbetweentheuprights,compressingitgently (springeffect).
•Makesurethatthestripsofinsulationareproperlybutt-jointedandthatthejointsbetweenthefloorandthewallsarecorrectlyinsulated(thermalandacousticalbridges).
1
2
3
Tip:
For optimum efficiency, in particular as regards
the acoustics of the partition, it is advisable:
• To add a resilient sole under the rails, on
the floor and the ceiling (reducing the
transmission of solid-borne noise – vibration)
• To place electrical cases (sockets or switches) in
staggered rows.
• To place a double facing on one of the sides
of the partition and to use Fermacell batts.
In the case of a single framework •PleaseconsultpointNb.6:Interior.
In the case of a double framework (dwelling separating partition)
•Placeasecondmetalframeworkatadistanceof40to60mmfromthepreviousone(consultpoint1).
•Inserttheinsulationhorizontallybetweenthetwometalframeworks.
•Inserttheinsulationverticallybetweentheuprightsofthesecondmetalframework(inaccordancewithpoint3).
•Ifneedbe,createamechanicaljointbetweenthetwopartitionsusingacousticrunners.
Interior •Optionallyincludetheelectriccableconducts.
•Cutthefacingstoceilingheightminus2cm.
•Positionthefacingsonwedges.Screwthemontotheuprights (max.centredistance30cm).
•Performthejointsbetweenfinishingbattssuchastoobtainaperfectsealbetweenthetwoparts.
•Ideally,applyasiliconjointtothefloor/facinginterfaceinordertoguaranteeair-andwater-tightness.Applythefinishingskirting.
4
5
6
Biofib’ insulation
Upright
Interiorfinish
Biofib’control
www.biofib-insulation.com
paCKaGinGhemp
Batts: dimensions: 1.25 x 0.6 m (0.75 m2)
Thickness (mm) Nb. sheets/package
Surface area/package (m2)
Nb. packages/pallet
Surface area/pallet (m2)
Nb. pallets/truck
Surface area/truck (m2)
45 15 11.25 8 90 22 1980
60 10 7.5 8 60 22 1320
80 7 5.25 8 42 22 924
100 6 4.5 8 36 22 792
200 3 2,25 8 18 22 396
Rolls: Width: 0.6 m
Thickness (mm)
Length(m)
Surface area/roll(m2)
Nb. rolls/pallet Surface area/pallet(m2)
Nb. pallets/truck
Surface area/truck (m2)
100 3.4 2.04 16 32.6 24 783
Batts: dimensions: 1.25 x 0.6 m (0.75 m2)
Thickness (mm) Nb. sheets/package
Surface area/package (m2)
Nb. packages/pallet
Surface area/pallet (m2)
Nb. pallets/truck
Surface area/truck (m2)
45 13 9,75 8 78 22 1716
60 10 7,5 8 60 22 1320
80 7 5,25 8 42 22 924
100 6 4,5 8 36 22 792
120 5 3,75 8 30 22 660
140 4 3 8 24 22 528
160 4 3 8 24 22 528
200 3 2,25 8 18 22 396
Rolls: Width: 0.6 m
Thickness (mm)
Length (m)
Surface area/roll (m2)
Nb. rolls/pallet Surface area/pallet (m2)
Nb. pallets/truck
Surface area/truck (m2)
100 3.4 2.04 16 32.6 24 783
Batts: dimensions: 1.25 x 0.6 m (0.75 m2)
Thickness (mm) Nb. sheets/package
Surface area/package (m2)
Nb. packages/pallet
Surface area/pallet (m2)
Nb. pallets/truck
Surface area/truck (m2)
45 13 9,75 8 78 22 1716
60 10 7,5 8 60 22 1320
100 6 4,5 8 36 22 792
120 5 3,75 8 30 22 660
140 4 3 8 24 22 528
Ca
ste
limprim
erie
- T
él. :
02
51 2
2 27
58
- 10
/201
3
Bag (kg) Nb. bags/pallet
Weight/pallet (kg)
Nb. pallet/truck
Weight/truck (Tons)
10 40 400 26 10,4
Bag (kg) Nb. bags/pallet
Weight/pallet (kg)
Nb. pallet/truck
Weight/truck (Tons)
15 70 1050 24 25,20
Big Bag (1 ton) 1000 24 24