INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM...
Transcript of INSULATED METAL COMPOSITE WALL SYSTEMsweets.construction.com/swts_content_files/23895/449621.pdfASTM...
I N S U L A T E D M E T A L C O M P O S I T E W A L L S Y S T E M
®
V e r s a w a l l
For an attractive and efficient wall, where long vertical
spans are desired, single-component CENTRIA Versawall
is an excellent alternative to traditional multi-component
wall systems.
These metal composite panels are formed with a
galvanized steel face and liner with preformed joinery
and thick, rigid CFC-free foam insulation. The result
is a remarkably strong but lightweight panel with an
extraordinary spanning capability. Panel lengths are
available up to 40’ [12.19mm] with insulation values as
high as R 27 [RSI 4.9]. Versawall panels install quickly
and easily in any weather.
Available in over 70 standard colors – including
micas and metallics, and textured Duracast® finish –
Versawall is appropriate for virtually any building type.
Office buildings, schools, hospitals, arenas, stadiums,
warehouses and industrial plants can all benefit from
the strength, beauty and efficiency of Versawall.
C O V E R P H O T O :M U S E U M O F F L I G H T, M I L I TA R Y G A L L E R YS E AT T L E , WA
Concealed clip fastening system provides a clean uninterruptedsurface and ability for panels to accommodate seismic forces
High-efficiency 90% closed cell CFC-free foam insulation
Thermal break prevents conduction between face and liner panels
Weathertight double tongue-and-groove vertical joinery with factory-applied non-curing vapor-resistant sealant that provides a complete air and vapor barrier
SPECIFICATIONS
SUBSTRATES
• Standard 26/26 gage [.45mm/.45mm], ASTM A653, Grade 37,G-90 galvanized steel face and liner with CFC-free insulated foam core
• Flat 22 gage [.75mm] face only• Optional gages available – consult CENTRIA
JOINERY
• Double tongue-and-groove joinery with factory-applied air and vapor seal
SURFACE FINISH
• Exterior – Non-directional embossing, striated, plankedor flat
• Interior – Non-directional embossing, planked
PANEL WIDTH
• 30” [762mm], 36” [914mm]
PANEL LENGTH
• 6’ [1.83m] to 40’ [12.19m] standard• Longer lengths available – consult CENTRIA
PANEL THICKNESS
• 2” [51mm], 2-3/4” [70mm], 4” [102mm]
“R” VALUE*
• 2” [51mm] depth – R14* [RSI 2.54]• 2-3/4” [70mm] depth – R19* [RSI 3.41]• 4” [102mm] depth – R27* [RSI 4.83]
*R-Values are based on ASTM C236 and C518 testing.Air films are included.
FINISHES AND COLORS
• Available in the industry’s widest variety of durablefinish systems in over 70 standard and unlimitedcustom colors, including micas and metallics
S T O C K T O N A R E N A A N D E V E N T C E N T E RS T O C K T O N , C A
T U L S A T E C H N O LO G Y C E N T E RT U L S A , O K 2
a l l i n o n e
STRIATED
PLANKED
FLAT
Exterior30” [762] or 36” [914mm]
2” [51mm],2-3/4” [70mm] or 4” [102mm]
Interior
Exterior30” [762] or 36” [914mm]
2” [51mm],2-3/4” [70mm] or 4” [102mm]
Interior
Exterior30” [762] or 36” [914mm]
2” [51mm],2-3/4” [70mm] or 4” [102mm]
Interior
V e r s a w a l l
Architects and owners also appreciate the environmental
benefits of Versawall.
In just one component – comprised of a limited amount
of material, with a high degree of both recycled and
recyclable content – a complete, long-lasting, energy-
efficient exterior wall is created.
Versawall’s efficient, rigid CFC-free foam insulation
does not harm the ozone layer, and materials such as
batt insulation, gypsum sheathing and building wrap
are entirely eliminated.
Plus, because Versawall is so lightweight – as light as
2.10 lbs./ft2 [10.25 kg/sqm]– a building’s structural and
foundation requirements can be dramatically reduced.
Architects frequently use the interior side of Versawall as the finished interior wall – further reducing material usage.
3
COMBINE VERSAWALL WITH A DURABLE TEXTURED FINISH
For a faster, easier and more economical alternative toprecast concrete, specify Versawall with CENTRIADuracast® textured finish. This permanent, nonabsorbentacrylic and silica aggregate coating is available in yourchoice of eight subtle earthtones. (Available on FlatEmbossed and Planked only.)
VERSAWALL WITH DURACAST
s i m p l y as o l u t i o n
U . S . N AV Y WA R E H O U S EN O R F O L K , VA
FLAT EMBOSSED
VVEERRSSAAWWAALLLL MMEEEETTSS OORR EEXXCCEEEEDDSS RREEQQUUIIRREEMMEENNTTSS OOFF TTHHEESSEE TTEESSTTSS::
ASTM E 72 Structural performance test
ASTM C 236 Thermal transmission test
ASTM 283-73 Air infiltration test
ASTM E 1646 Water penetration test
ASTM E 84 (UL 723) Burning characteristic test
ASTM D 1929 Ignition temperature test
UL 263 Fire resistant rating test
MEA #330-05-M New York City approval(2” [51mm] panel)
FM 4880 Class 1 insulated wall or ceiling panel
4
Specify Versawall’s exterior surface with non-directionalembossing, either subtly striated or lightly planked. Theinterior surface finish is non-directional embossed andlightly planked.
STRIATED
PLANKED
M Y S T I C A Q UA R I U MM Y S T I C , C T
U . S . N AV Y WA R E H O U S EN O R F O L K , VA
V e r s a w a l l
• Provides excellent thermal efficiency and
moisture protection in a single component
• Lightweight panels with long spanning
capability reduce the building's structural
support requirements and reduce
installation costs
• Faster and easier installation in any type
of weather or climate
• Concealed clips and fasteners provide a
clean uninterrupted surface
• Available with preformed sheet metal
flashing or extruded aluminum trim
• Creates a complete, thermally efficient
exterior wall, using far less material
• Made of 100% recyclable steel with a
high degree of recycled content
• CENTRIA nationwide network of trained
dealers and installers
• Backed by CENTRIA, with over a century
of experience and excellence
B E N E F I T S O F V E R S A W A L L
5*Polyvinylidene Fluoride (PVDF) coat contains 70% Kynar 500 or Hylar
5000 resin. Kynar 500 is a Reg. TM of Arkema, Inc. Corporation. Hylar5000 is a Reg. TM of Solvay Solexis, Inc. Galvalume is a Reg. TM ofBIEC International, Inc.
t h a t b e g i n s w i t h p r o t e c t i v e c o a t i n g s
.8 mil nominal PVDF Coat3.0 mil nominal Versacor Ultra Barrier Coat
.8 mil nominal Polyvinylidene Fluoride Coat (clear)*
.8 mil nominal Primer Coat
.8 mil nominal Polyvinylidene Fluoride Coat (color)*
Substrate
.8 mil nominal Primer Coat
.8 mil nominal Polyvinylidene Fluoride Coat (color)*
Substrate
DURAGARD® PLUSA premium, high build architecturalcoating providing the ultimate in colorretention and fade resistance.
DURAGARD®
.5 mil nominal Polyvinylidene Fluoride Coat (clear)*
.2 mil nominal Primer Coat
.8 mil nominal Polyvinylidene Fluoride Coat (color)*
Substrate
METALLIC 3-COATA quality, durable coating providing theiridescence and reflectivity of a metallicsurface.
VERSACOR® ULTRA PFA premium, high build, multi-layercoating for applications wherecorrosion resistance is more important.
FLUOROFINISH® *, MICA* ANDBRILLIANT SERIESEconomical Kynar 500®, Hylar 5000®
or FEVE-based coating providinggood durability.
.2 mil nominal Primer CoatSubstrate
.8 mil nominal Color Coat
Acrylic and Natural Aggregate Matrix.8 mil nominal Polyester.2 mil nominal PrimerSubstrate
DURACASTA textured coating consisting of apermanent, non-absorbent acrylic andsilica coating. (Available on Versapanelwalls only)
VERSACOR® ULTRA TF AND HF
3.0 mil nominal Versacor Ultra Barrier Coat1.5 or 3.0 mil nominal Urethane Coat (color)*
VVersawall Detailsersawall Details
66
2008Versawall details.indd 6 10/22/08 2:29:10 AM
7
PRODUCT INFORMATION
Versawall - Striated, Planked or Flat ..........8, 9
PRODUCT PROFILES
Versawall Striated..........................................10
Versawall Planked ........................................11
Versawall Embossed Flat ..............................12
Versawall Joint - 2.00 ....................................13
Versawall Joint - 2.75 ....................................14
Versawall Joint - 4.00 ....................................15
VERSAWALL APPLICATION DETAILS
Base at Curb w/ Extrusion ............................16
Base at Curb ................................................17
Base at Slab w/ Extrusion ............................18
Base at Slab ..................................................19
ATMP Base at Slab ......................................20
Stack Joint w/ Extrusion ................................21
ATMP Stack ..................................................22
Stack Joint ....................................................23
Parapet w/ Extrusion ....................................24
Parapet ..........................................................25
Head w/ Extrusion at Opening ......................26
ATMP Head at Opening ................................27
Head at Opening ..........................................28
Jamb w/ Extrusion ........................................29
ATMP Jamb at Opening ................................30
Jamb..............................................................31
Sill ..................................................................32
Wall - Soffit w/ Extrusion ..............................33
Soffit - Wall w/ Extrusion ..............................34
Wall - Soffit ....................................................35
Soffit - Wall ....................................................36
Jamb at Masonry w/ Extrusion ......................37
Jamb at Masonry ..........................................38
Inside Corner w/ Extrusion ............................39
Inside Corner ................................................40
Outside Corner w/ Extrusion ........................41
Outside Corner ..............................................42
Expansion Joint w/ Extrusion ........................43
Expansion Joint ............................................44
LOAD / SPAN TABLES
30” Versawall Wind Load ........................45, 46
36” Versawall Wind Load ........................47, 48
INDEX
CENTRIA reserves the right to change information in this manual without prior notice.
This manual illustrates design information and application details for CENTRIA Versawall products. The information contained herein is not intended to assure performance for each particular application. CENTRIA accepts no liability arising from the use of this information and excludes any implied warranty of fitness for a particular purpose or merchantablility with respect to the products described.
2008Versawall details.indd 7 10/22/08 2:29:10 AM
20, 22, 24 ga. embossed, planked
Versawall 4.00 - U=0.036 (R=27.34)Versawall 2.75 - U=0.049 (R=20.24)Versawall 2.00 - U=0.069 (R=14.41)
Versawall wall panels incorporate a finished interior liner, factory applied air and vapor seal,insulating foam core and finished exterior weathering surface into a single building unit.The composite action resulting from the chemical bond between the poured in place foamcore and the steel skins creates a lightweight, rigid unit with excellent spanning capacity.
Double Tongue & Groove
20, 22, 24 ga. embossed and striated
26 ga. embossed and striated or
26 ga. embossed, planked
Non-directional embossing
(optional)
(standard)
(optional)
(standard)
(standard)(optional)(optional)(standard)
Interior Liner
Lengths
Texture
Finishes
Core Material
Thermal Properties
Exterior Face
Base Material
6 ft. to 40 ft. (36 ft max. for flat face)1 ft. min. to 6 ft.40 ft. to 48 ft. max.
See Finishes Brochure
Isocyanurate foam
G-90 galvanized steel
Panel ThicknessPanel Module
End JointSide Joint
Panel Availability2", 2 3/4", or 4"30", 36"
Butt - see DetailsInformation is available on special applications such asfire-rated walls, corrosive exposure considerations,pressure release walls, special material and coatingrequirements as well as many other pertinent subjects;contact your local CENTRIA Sales Representative.
Maximum support spacing & panel length may belimited for medium & dark colors due to thermalstress, consult CENTRIA Design & Developement.
Brake-formed flashings
Extruded flashings
Others as required for job completion
Attachment clips
1.Notes
Accessories
2.3.4.5.
1.
7.8.
6.
Flat stock
Windows (2" thick panels only)
FastenersSealants
Special Applications
Oct08
VERSAWALL PROMOTIONALDATA # 0001
4. A METRIC version of this Tech Data sheet isavailable (see Promotional Data #0001m).
*
"Rounded R-values based on ASTM C1363test .... air films included"
*
(standard)(optional)
Profiles striated (face only)planked
26 ga. embossed and planked
20, 22, 24 ga. embossed and planked22 ga. embossed and flat
(optional) embossed flat (face only)
2. Flat faced panel maximum length for light andmedium colors is 36'. For dark colors maximumlength is 20'-9".
3. 4" thick panels are not available with a flat face.
PANEL MODULE
1/8" JOINT
PANEL MODULE
PANEL MODULE PANEL MODULE
1/8" JOINT
2.00 PANEL JOINT 2.75 PANEL JOINT(4.00 PANEL JOINT SIMILAR)
8
2008Versawall details.indd 8 10/22/08 2:29:11 AM
.90, .75, .60mm embossed, planked
Versawall 102mm - U=0.207 (RSI=4.84)Versawall 70mm - U=0.278 (RSI=3.59)Versawall 51mm - U=0.392 (RSI=2.55)
Versawall wall panels incorporate a finished interior liner, factory applied air and vapor seal,insulating foam core and finished exterior weathering surface into a single building unit.The composite action resulting from the chemical bond between the poured in place foamcore and the steel skins creates a lightweight, rigid unit with excellent spanning capacity.
Double Tongue & Groove
.90, .75, .60mm embossed, striatedor planked
.45mm embossed, striated or planked
.45mm embossed, planked
Non-directional embossing
(optional)
(standard)(optional)
(standard)
(standard)(optional)(optional)(standard)
Interior Liner
Lengths
Texture
Finishes
Core Material
Thermal Properties
Exterior Face
Base Material
1.83m to 12.19m (see note 2).3m min. to 1.83m12.19m to 14.63m max.
See Finishes Brochure
Isocyanurate foam
G-90 galvanized steel
Panel ThicknessPanel Module
End JointSide Joint
Panel Availability51mm, 70mm or 102mm762mm, 914mm
Butt - see DetailsInformation is available on special applications such asfire-rated walls, corrosive exposure considerations,pressure release walls, special material and coatingrequirements as well as many other pertinent subjects;contact your local CENTRIA Sales Representative.
Brake-formed flashings
Extruded flashings
Others as required for job completion
Attachment clips
Accessories
2.3.4.5.
1.
7.8.
6.
Flat stock
Windows (51mm thick panels only)
FastenersSealants
Special Applications
Oct08
PROMOTIONALDATA # 0001_m
U{W/(m K)}2*
"Rounded R-values based on ASTM C1363 test .... air films included"
*
(standard)(optional)
Profiles striated (face only)planked
VERSAWALL SI Units
Maximum support spacing & panel length may belimited for medium & dark colors due to thermalstress, consult CENTRIA Design & Developement.
1.Notes
2. Flat faced panel maximum length for light andmedium colors is 10.9m. For dark colorsmaximum length is 6.32m.
3. 102mm thick panels are not available with aflat face.
.75mm embossed, flat
(optional) embossed flat (face only)
PANEL MODULE
3mm JOINT
PANEL MODULE
PANEL MODULE PANEL MODULE
3mm JOINT
51mm PANEL JOINT 70mm PANEL JOINT(102mm PANEL JOINT SIMILAR)
9
2008Versawall details.indd 9 10/22/08 2:29:12 AM
STR
IATE
D V
ER
SAW
ALL
VERSAWALL PROMOTIONALPROFILE # 0001
Oct08
10
2008Versawall details.indd 10 10/22/08 2:29:13 AM
PLA
NK
ED
VE
RS
AWAL
L
VERSAWALL PROMOTIONALPROFILE # 0002
Oct08
11
2008Versawall details.indd 11 10/22/08 2:29:14 AM
FLA
T V
ER
SAW
ALL
VERSAWALL PROMOTIONALPROFILE # 0003
Oct08
12
2008Versawall details.indd 12 10/22/08 2:29:15 AM
Oct08
VERSAWALL PROMOTIONALPROFILE # 0004
13
2008Versawall details.indd 13 10/22/08 2:29:16 AM
VERSAWALL
14
2008Versawall details.indd 14 10/22/08 2:29:16 AM
Oct08
PROMOTIONALPROFILE # 0006VERSAWALL
15
2008Versawall details.indd 15 10/22/08 2:29:17 AM
VERSAWALLPANEL TYPES
16
2008Versawall details.indd 16 10/22/08 2:29:17 AM
VERSAWALLPANEL TYPES
17
2008Versawall details.indd 17 10/22/08 2:29:18 AM
VERSAWALLPANEL TYPES
18
2008Versawall details.indd 18 10/22/08 2:29:19 AM
VERSAWALLPANEL TYPES
19
2008Versawall details.indd 19 10/22/08 2:29:19 AM
VERSAWALLPANEL TYPE
20
2008Versawall details.indd 20 10/22/08 2:29:20 AM
VERSAWALLPANEL TYPES
21
2008Versawall details.indd 21 10/22/08 2:29:20 AM
VERSAWALLPANEL TYPE
22
2008Versawall details.indd 22 10/22/08 2:29:21 AM
VERSAWALLPANEL TYPES
23
2008Versawall details.indd 23 10/22/08 2:29:22 AM
VERSAWALLPANEL TYPES
24
2008Versawall details.indd 24 10/22/08 2:29:22 AM
VERSAWALLPANEL TYPES
25
2008Versawall details.indd 25 10/22/08 2:29:23 AM
VERSAWALLPANEL TYPES
26
2008Versawall details.indd 26 10/22/08 2:29:23 AM
VERSAWALLPANEL TYPE
27
2008Versawall details.indd 27 10/22/08 2:29:24 AM
VERSAWALLPANEL TYPES
28
2008Versawall details.indd 28 10/22/08 2:29:25 AM
VERSAWALLPANEL TYPES
29
2008Versawall details.indd 29 10/22/08 2:29:25 AM
VERSAWALLPANEL TYPE
30
2008Versawall details.indd 30 10/22/08 2:29:26 AM
VERSAWALLPANEL TYPES
31
2008Versawall details.indd 31 10/22/08 2:29:26 AM
VERSAWALLPANEL TYPES
32
2008Versawall details.indd 32 10/22/08 2:29:27 AM
VERSAWALLPANEL TYPES
33
2008Versawall details.indd 33 10/22/08 2:29:27 AM
VERSAWALLPANEL TYPES
34
2008Versawall details.indd 34 10/22/08 2:29:28 AM
VERSAWALLPANEL TYPES
35
2008Versawall details.indd 35 10/22/08 2:29:29 AM
VERSAWALLPANEL TYPES
36
2008Versawall details.indd 36 10/22/08 2:29:29 AM
VERSAWALLPANEL TYPES
37
2008Versawall details.indd 37 10/22/08 2:29:30 AM
VERSAWALLPANEL TYPES
38
2008Versawall details.indd 38 10/22/08 2:29:31 AM
VERSAWALLPANEL TYPES
39
2008Versawall details.indd 39 10/22/08 2:29:31 AM
VERSAWALLPANEL TYPES
40
2008Versawall details.indd 40 10/22/08 2:29:32 AM
VERSAWALLPANEL TYPES
41
2008Versawall details.indd 41 10/22/08 2:29:33 AM
VERSAWALLPANEL TYPES
42
2008Versawall details.indd 42 10/22/08 2:29:33 AM
VERSAWALLPANEL TYPES
43
2008Versawall details.indd 43 10/22/08 2:29:34 AM
VERSAWALLPANEL TYPES
44
2008Versawall details.indd 44 10/22/08 2:29:35 AM
Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60
1 12'-0''* 11'-5'' 9'-6'' 8'-2'' 7'-2'' 6'-4'' 5'-9'' 5'-2'' 4'-9''2 12'-0''* 12'-0''* 11'-7'' 10'-0'' 8'-10'' 7'-11'' 7'-1'' 6'-4'' 5'-9''3 12'-0''* 12'-0''* 11'-9'' 10'-1'' 8'-9'' 7'-9'' 7'-0'' 6'-3'' 5'-9''1 12'-0''* 12'-0''* 12'-0''* 10'-6'' 9'-2'' 8'-2'' 7'-4'' 6'-8'' 6'-2''2 12'-0''* 12'-0''* 11'-9'' 10'-2'' 9'-0'' 8'-0'' 7'-3'' 6'-8'' 6'-2''3 12'-0''* 12'-0''* 12'-0''* 10'-7'' 9'-4'' 8'-4'' 7'-6'' 6'-10'' 6'-4''1 12'-0''* 11'-5'' 9'-6'' 8'-2'' 7'-2'' 6'-4'' 5'-9'' 5'-2'' 4'-9''2 12'-0''* 12'-0''* 11'-8'' 10'-1'' 8'-11'' 7'-10'' 7'-0'' 6'-2'' 5'-7''3 12'-0''* 12'-0''* 11'-9'' 10'-0'' 8'-9'' 7'-8'' 6'-11'' 6'-3'' 5'-8''1 12'-0''* 12'-0''* 12'-0''* 10'-6'' 9'-2'' 8'-2'' 7'-4'' 6'-8'' 6'-2''2 12'-0''* 12'-0''* 11'-10'' 10'-3'' 9'-1'' 8'-2'' 7'-5'' 6'-9'' 6'-3''3 12'-0''* 12'-0''* 12'-0''* 11'-2'' 9'-9'' 8'-9'' 7'-10'' 7'-2'' 6'-7''1 12'-0''* 11'-8'' 9'-8'' 8'-4'' 7'-3'' 6'-6'' 5'-10'' 5'-3'' 4'-10''2 12'-0''* 12'-0''* 11'-9'' 10'-2'' 8'-10'' 7'-9'' 6'-10'' 6'-2'' 5'-7''3 12'-0''* 12'-0''* 11'-11'' 10'-1'' 8'-9'' 7'-9'' 7'-0'' 6'-3'' 5'-8''1 12'-0''* 12'-0''* 12'-0''* 12'-0''* 11'-0'' 9'-9'' 8'-9'' 8'-0'' 7'-3''2 12'-0''* 12'-0''* 12'-0'' 10'-5'' 9'-2'' 8'-3'' 7'-6'' 6'-11'' 6'-5''3 12'-0''* 12'-0''* 12'-0''* 11'-2'' 9'-10'' 8'-9'' 8'-0'' 7'-3'' 6'-8''
Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60
1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-3'' 9'-1'' 7'-8'' 6'-8'' 5'-10'' 5'-3'' 4'-9'' 4'-5'' 4'-1''3 12'-0''* 10'-1'' 8'-5'' 7'-3'' 6'-4'' 5'-8'' 5'-1'' 4'-8'' 4'-3''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-5'' 9'-3'' 7'-10'' 6'-9'' 6'-0'' 5'-5'' 4'-11'' 4'-6'' 4'-2''3 12'-0''* 10'-1'' 8'-5'' 7'-3'' 6'-4'' 5'-8'' 5'-2'' 4'-8'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-4'' 9'-2'' 7'-9'' 6'-9'' 6'-0'' 5'-4'' 4'-10'' 4'-6'' 4'-2''3 12'-0''* 10'-1'' 8'-5'' 7'-3'' 6'-4'' 5'-8'' 5'-1'' 4'-8'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-6'' 9'-4'' 7'-11'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7'' 4'-3''3 12'-0''* 10'-1'' 8'-6'' 7'-3'' 6'-5'' 5'-9'' 5'-2'' 4'-9'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-5'' 9'-3'' 7'-10'' 6'-10'' 6'-1'' 5'-5'' 5'-0'' 4'-7'' 4'-2''3 12'-0''* 10'-1'' 8'-6'' 7'-3'' 6'-5'' 5'-8'' 5'-2'' 4'-8'' 4'-4''1 12'-0''* 11'-0'' 9'-2'' 7'-10'' 6'-11'' 6'-1'' 5'-6'' 5'-0'' 4'-7''2 11'-8'' 9'-6'' 8'-1'' 7'-0'' 6'-3'' 5'-7'' 5'-1'' 4'-8'' 4'-4''3 12'-0''* 10'-2'' 8'-6'' 7'-4'' 6'-5'' 5'-9'' 5'-3'' 4'-9'' 4'-5''
Explanatory Notes for Load/Span Table:1. Spans are limited to a maximum deflection of L/120 for positive wind load.2. Spans are based on 1 fastener with an allowable pullout capacity of 1064 lb. per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 344 lb. each per interior clip when fastened into 16 Ga. supports.3. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.4. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.5. Contact CENTRIA for conditions not conforming to these notes.
22/22
22/22
26/26
4.00
26/26
26/26
22/22
22/22
26/26
22/22
2.00
2.75
Load-psf
Load - psf
30" Module Panel Fastened into 16 Gage Steel Supports
30" Module Panel Fastened into 3/16" Steel Supports
4.00
2.00
26/26
22/22
2.75
26/26
VERSAWALL
Oct 08 45
2008Versawall details.indd 45 10/22/08 2:29:37 AM
46
VERSAWALL
Metric Wind Loads for 30" ModuleVersawall Wall PanelsOct 08
Thickness Gage No.(mm) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00
1 3.66* 3.33 2.78 2.38 2.08 1.85 1.67 1.52 1.392 3.66* 3.66* 3.39 2.92 2.58 2.31 2.05 1.84 1.673 3.66* 3.66* 3.44 2.93 2.55 2.26 2.02 1.83 1.671 3.66* 3.66* 3.58 3.07 2.68 2.39 2.15 1.95 1.792 3.66* 3.66* 3.43 2.97 2.62 2.35 2.13 1.96 1.813 3.66* 3.66* 3.60 3.09 2.72 2.43 2.20 2.00 1.841 3.66* 3.33 2.78 2.38 2.08 1.85 1.67 1.52 1.392 3.66* 3.66* 3.41 2.95 2.59 2.27 2.01 1.80 1.633 3.66* 3.66* 3.42 2.92 2.54 2.24 2.01 1.81 1.651 3.66* 3.66* 3.58 3.07 2.68 2.39 2.15 1.95 1.792 3.66* 3.66* 3.46 3.00 2.65 2.38 2.16 1.99 1.843 3.66* 3.66* 3.66* 3.26 2.86 2.55 2.30 2.10 1.931 3.66* 3.39 2.83 2.42 2.12 1.89 1.70 1.54 1.412 3.66* 3.66* 3.44 2.98 2.58 2.25 1.99 1.78 1.613 3.66* 3.66* 3.46 2.95 2.56 2.26 2.02 1.81 1.651 3.66* 3.66* 3.66* 3.65 3.19 2.84 2.55 2.32 2.132 3.66* 3.66* 3.51 3.05 2.70 2.42 2.20 2.02 1.873 3.66* 3.66* 3.66* 3.27 2.87 2.56 2.31 2.11 1.94
Thickness Gage No.(in.) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00
1 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.29 2.66 2.24 1.94 1.72 1.54 1.40 1.29 1.193 3.66* 2.94 2.45 2.11 1.85 1.65 1.49 1.36 1.251 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.31 2.70 2.29 1.98 1.76 1.58 1.44 1.32 1.223 3.66* 2.95 2.47 2.12 1.86 1.66 1.50 1.37 1.261 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.33 2.69 2.27 1.97 1.74 1.57 1.43 1.31 1.213 3.66* 2.94 2.46 2.12 1.86 1.66 1.50 1.37 1.261 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.36 2.74 2.32 2.02 1.79 1.61 1.46 1.34 1.243 3.66* 2.96 2.48 2.13 1.87 1.67 1.51 1.38 1.271 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.35 2.72 2.30 2.00 1.77 1.60 1.45 1.33 1.233 3.66* 2.95 2.47 2.13 1.87 1.67 1.51 1.38 1.271 3.66* 3.21 2.68 2.30 2.01 1.79 1.61 1.46 1.342 3.41 2.78 2.36 2.05 1.82 1.64 1.49 1.37 1.263 3.66* 2.97 2.49 2.14 1.89 1.69 1.52 1.39 1.28
Explanatory Notes for Load/Span Table:1. Spans given in meters.2. Spans are limited to a maximum deflection of L/120 for positive wind load.3. Spans are based on 1 fastener with an allowable pullout capacity of 483 kg (1064 lb) per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 156 kg (344 lb) each per interior clip when fastened into 16 Ga. supports.4. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.5. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.6. Contact CENTRIA for conditions not conforming to these notes.
762 mm (30") Module Panel Fastened into 4.75 mm (3/16") Steel Supports
102(4.00")
50(2.00")
26/26
22/22
70(2.75")
26/26
26/26
22/22
50(2.00")
70(2.75")
Load-psf
Load - kPa
762 mm (30") Module Panel Fastened into 1.50 mm (16 Gage) Steel Supports
22/22
22/22
26/26
102(4.00")
26/26
26/26
22/22
22/22
2008Versawall details.indd 46 10/22/08 2:29:39 AM
47
Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60
1 11'-11'' 9'-6'' 8'-0'' 6'-10'' 6'-0'' 5'-3'' 4'-9'' 4'-4'' 4'-0''2 12'-0''* 11'-7'' 9'-9'' 8'-5'' 7'-5'' 6'-6'' 5'-9'' 5'-2'' 4'-8''3 12'-0''* 11'-9'' 9'-9'' 8'-4'' 7'-3'' 6'-5'' 5'-9'' 5'-2'' 4'-9''1 12'-0''* 12'-0''* 10'-3'' 8'-9'' 7'-8'' 6'-10'' 6'-2'' 5'-7'' 5'-1''2 12'-0''* 11'-9'' 9'-10'' 8'-7'' 7'-7'' 6'-9'' 6'-2'' 5'-8'' 5'-3''3 12'-0''* 12'-0''* 10'-10'' 9'-4'' 8'-2'' 7'-3'' 6'-7'' 6'-0'' 5'-6''1 11'-11'' 9'-6'' 8'-0'' 6'-10'' 6'-0'' 5'-3'' 4'-9'' 4'-4'' 4'-0''2 12'-0''* 11'-8'' 9'-10'' 8'-5'' 7'-3'' 6'-4'' 5'-7'' 5'-0'' 4'-6''3 12'-0''* 11'-9'' 9'-9'' 8'-3'' 7'-2'' 6'-4'' 5'-8'' 5'-1'' 4'-8''1 12'-0''* 12'-0''* 10'-3'' 8'-9'' 7'-8'' 6'-10'' 6'-2'' 5'-7'' 5'-1''2 12'-0''* 11'-10'' 10'-0'' 8'-8'' 7'-8'' 6'-11'' 6'-3'' 5'-9'' 5'-4''3 12'-0''* 12'-0''* 10'-10'' 9'-4'' 8'-2'' 7'-4'' 6'-7'' 6'-0'' 5'-6''1 12'-0''* 9'-8'' 8'-1'' 7'-0'' 6'-1'' 5'-5'' 4'-10'' 4'-5'' 4'-0''2 12'-0''* 11'-9'' 10'-0'' 8'-5'' 7'-2'' 6'-3'' 5'-7'' 5'-0'' 4'-6''3 12'-0''* 11'-11'' 9'-10'' 8'-4'' 7'-3'' 6'-4'' 5'-8'' 5'-1'' 4'-8''1 12'-0''* 12'-0''* 12'-0''* 10'-5'' 9'-1'' 8'-1'' 7'-3'' 6'-8'' 6'-1''2 12'-0''* 12'-0''* 10'-2'' 8'-10'' 7'-10'' 7'-0'' 6'-5'' 5'-10'' 5'-5''3 12'-0''* 12'-0''* 10'-11'' 9'-5'' 8'-3'' 7'-4'' 6'-8'' 6'-1'' 5'-7''
Thickness Gage No.(in.) Face/Liner Spans 20 25 30 35 40 45 50 55 60
1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-5'' 7'-8'' 6'-6'' 5'-7'' 5'-0'' 4'-6'' 4'-1'' 3'-9'' 3'-5''3 10'-6'' 8'-5'' 7'-0'' 6'-0'' 5'-4'' 4'-9'' 4'-3'' 3'-11'' 3'-7''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-7'' 7'-10'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10'' 3'-6''3 10'-6'' 8'-5'' 7'-1'' 6'-1'' 5'-4'' 4'-9'' 4'-4'' 4'-0'' 3'-7''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-6'' 7'-9'' 6'-7'' 5'-8'' 5'-0'' 4'-6'' 4'-2'' 3'-9'' 3'-6''3 10'-6'' 8'-5'' 7'-1'' 6'-1'' 5'-4'' 4'-9'' 4'-4'' 4'-0'' 3'-7''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-8'' 7'-11'' 6'-8'' 5'-10'' 5'-2'' 4'-8'' 4'-3'' 3'-11'' 3'-7''3 10'-6'' 8'-6'' 7'-1'' 6'-1'' 5'-5'' 4'-10'' 4'-4'' 4'-0'' 3'-8''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-8'' 7'-10'' 6'-8'' 5'-9'' 5'-2'' 4'-7'' 4'-2'' 3'-10'' 3'-7''3 10'-6'' 8'-6'' 7'-1'' 6'-1'' 5'-4'' 4'-9'' 4'-4'' 4'-0'' 3'-8''1 11'-6'' 9'-2'' 7'-8'' 6'-7'' 5'-9'' 5'-1'' 4'-7'' 4'-2'' 3'-10''2 9'-10'' 8'-1'' 6'-10'' 6'-0'' 5'-3'' 4'-9'' 4'-4'' 4'-0'' 3'-8''3 10'-7'' 8'-6'' 7'-2'' 6'-2'' 5'-5'' 4'-10'' 4'-5'' 4'-0'' 3'-8''
Explanatory Notes for Load/Span Table:1. Spans are limited to a maximum deflection of L/120 for positive wind load.2. Spans are based on 1 fastener with an allowable pullout capacity of 1064 lb. per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 344 lb. each per interior clip when fastened into 16 Ga. supports.3. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.4. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.5. Contact CENTRIA for conditions not conforming to these notes.
Load-psf
Load - psf
36" Module Panel Fastened into 16 Gage Steel Supports
36" Module Panel Fastened into 3/16" Steel Supports
4.00
2.00
26/26
22/22
2.75
26/26
4.00
26/26
26/26
22/22
22/22
26/26
22/22
2.00
2.75
22/22
22/22
26/26
VERSAWALL
Oct 08
2008Versawall details.indd 47 10/22/08 2:29:41 AM
48
VERSAWALL
Metric Wind Loads for 36" Module Versawall Wall PanelsOct 08
Thickness Gage No.(mm) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00
1 3.47 2.78 2.32 1.98 1.74 1.54 1.39 1.26 1.162 3.66* 3.39 2.85 2.46 2.15 1.88 1.67 1.49 1.353 3.66* 3.44 2.85 2.43 2.11 1.87 1.67 1.51 1.371 3.66* 3.58 2.98 2.56 2.24 1.99 1.79 1.63 1.492 3.66* 3.43 2.89 2.50 2.22 1.99 1.81 1.66 1.533 3.66* 3.66* 3.16 2.72 2.38 2.12 1.92 1.75 1.611 3.47 2.78 2.32 1.98 1.74 1.54 1.39 1.26 1.162 3.66* 3.41 2.87 2.45 2.10 1.84 1.63 1.45 1.313 3.66* 3.42 2.84 2.41 2.09 1.85 1.65 1.48 1.351 3.66* 3.58 2.98 2.56 2.24 1.99 1.79 1.63 1.492 3.66* 3.46 2.92 2.54 2.25 2.02 1.84 1.69 1.563 3.66* 3.66* 3.17 2.73 2.39 2.14 1.93 1.76 1.621 3.54 2.83 2.36 2.02 1.77 1.57 1.41 1.29 1.182 3.66* 3.44 2.90 2.44 2.09 1.82 1.61 1.44 1.303 3.66* 3.46 2.86 2.43 2.10 1.85 1.65 1.48 1.351 3.66* 3.66* 3.55 3.04 2.66 2.36 2.13 1.94 1.772 3.66* 3.51 2.97 2.58 2.29 2.06 1.87 1.72 1.593 3.66* 3.66* 3.18 2.74 2.41 2.15 1.94 1.77 1.63
Thickness Gage No.(in.) Face/Liner Spans 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00
1 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.77 2.24 1.89 1.64 1.46 1.31 1.19 1.09 1.013 3.06 2.54 2.05 1.77 1.55 1.38 1.25 1.14 1.051 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.81 2.29 1.94 1.68 1.49 1.34 1.22 1.12 1.043 3.07 2.47 2.06 1.78 1.56 1.40 1.26 1.15 1.061 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.79 2.27 1.92 1.67 1.48 1.33 1.21 1.11 1.033 3.07 2.46 2.06 1.77 1.56 1.39 1.26 1.15 1.061 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.84 2.32 1.97 1.71 1.52 1.37 1.24 1.14 1.053 3.08 2.48 2.07 1.79 1.57 1.41 1.27 1.16 1.071 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.83 2.30 1.95 1.70 1.51 1.36 1.23 1.13 1.053 3.07 2.47 2.07 1.78 1.57 1.40 1.27 1.16 1.061 3.35 2.68 2.23 1.91 1.67 1.49 1.34 1.22 1.122 2.89 2.36 2.00 1.74 1.55 1.39 1.26 1.16 1.073 3.09 2.49 2.09 1.80 1.59 1.42 1.28 1.17 1.08
Explanatory Notes for Load/Span Table:1. Spans given in meters.2. Spans are limited to a maximum deflection of L/120 for positive wind load.3. Spans are based on 1 fastener with an allowable pullout capacity of 483 kg (1064 lb) per interior clip when fastened into 3/16" steel supports and 2 fasteners with an allowable pullout capacity of 156 kg (344 lb) each per interior clip when fastened into 16 Ga. supports.4. Spans for 26/26 gage panels shown above are valid for 22/26 gage panels.5. * Spans limited by thermal stress and thermal bow considerations. For dark colored panels, further panel length and span restrictions may be necessary due to thermal stress. Contact CENTRIA.6. Contact CENTRIA for conditions not conforming to these notes.
915 mm (36") Module Panel Fastened into 4.75 mm (3/16") Steel Supports
102(4.00")
50(2.00")
26/26
22/22
70(2.75")
26/26
26/26
22/22
50(2.00")
70(2.75")
Load-psf
Load - kPa
915 mm (36") Module Panel Fastened into 1.50 mm (16 Gage) Steel Supports
22/22
22/22
26/26
102(4.00")
26/26
26/26
22/22
22/22
2008Versawall details.indd 48 10/22/08 2:29:44 AM
Notes
2008Versawall details.indd 49 10/22/08 2:29:44 AM
Notes
2008Versawall details.indd 50 10/22/08 2:29:45 AM
800.759.74741005 Beaver Grade Road, Moon Township, PA 15108-2944
412.299.8000; Fax: 412.299.8317
Reference VWDM-10/08-10M-NJ/GCS Copyright © 2008 CENTRIA Printed in U.S.A.
w w w . C E N T R I A . c o m