Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is...

36
Instructions 2178 Fiber Optic Splice Case Issue 3, March 1992

Transcript of Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is...

Page 1: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

Instructions

2178 Fiber Optic Splice Case

Issue 3, March 1992

Page 2: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

2

Contents:

1.0 General ......................................................................................................................................................... 3 2.0 Specifications ............................................................................................................................................... 3 3.0 Kit Contents .................................................................................................................................................. 3 4.0 Cable/Splice/Kit Matrix ................................................................................................................................. 6

SECTION 1: 2178 SPLICE CASE INSTRUCTIONS............................................................................................. 9

5.0 Cable Preparation ........................................................................................................................................ 9 6.0 Mid-Span Splice (Balloon Splice) ................................................................................................................. 9 7.0 Bonding for Shielded Cable .......................................................................................................................... 11 8.0 Core Blocking ............................................................................................................................................... 12 9.0 Sealing Washer Installation .......................................................................................................................... 1610.0 Grounding for Shielded Cable ...................................................................................................................... 1711.0 Buffer Tube and Ribbon Cable Preparation ................................................................................................. 1912.0 Universal Organizer Adapter ........................................................................................................................ 2013.0 Splice Trays and Fiber Splicing .................................................................................................................... 2114.0 Splice Preparation ........................................................................................................................................ 2615.0 Splice Case Assembly .................................................................................................................................. 2616.0 Racking in Building Entrances and Vaults .................................................................................................... 2817.0 Splice Case Re-entry ................................................................................................................................... 29

SECTION 2: 2181 CABLE ADDITION KIT............................................................................................................ 30

18.0 Cable Addition Placement, Preparation and Installation (Butt Adapter) ....................................................... 3019.0 Butt Adapter 1 Installation ............................................................................................................................ 3020.0 Splice Case Assembly with One Adapter ..................................................................................................... 3121.0 Cable Addition Placement, Preparation and Installation (Two Adapters) ..................................................... 3222.0 Butt Adapter 2 Installation ............................................................................................................................ 3323.0 Splice Case Assembly with Two Adapters ................................................................................................... 3324.0 Splice Case Re-entry with Butt Adapters ..................................................................................................... 34

Page 3: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

3

1.0 General

The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestalapplications. The splice case has two cable entrance ports on each end. Port plugs allow the case to beused for butt or inline splices. The rigid nonfilled case provides moisture protection and can be pressurized.

The integral organizer and splicing trays accommodate single-mode and multi-mode fiber optic field splices.Three series of trays are available: The 2116 Splice Tray for fusion splices, the 2118 Splice Tray formechanical splices, and the 2120 Splice Tray for rotary splices. Splice trays and bonding and groundinghardware are not included in the kits.

The Universal Organizer Adapter allows the 2178 Splice Case to accommodate other splice trays when the2116, 2118 and 2120 are not used. Splice trays which will work with the Universal Organizer Adapter include3M 2524 FibrlokTM Tray and 2524F Fusion Tray, AT&T, UC Series, Siecor, Ditel, Preform and NorthernTelecom. One Universal Organizer Adapter is included with the splice case. For further information, seemanufacturer's tray size specifications on page 3.

The 2180 Cable Kit is used when the 2178 Fiber Optic Splice Case is reentered. All materials necessary forcable addition and splice case reassembly are included.

The 2181 Cable Addition Kit increases the cable entrance capacity of the 2178 Fiber Optic Splice Case. Onebutt adapter is included in each 2181 Kit. A single butt adapter allows the 2178 Splice Case to accommodatefour cables in a butt configuration or eight cables total. Double stacking the butt adapter increases thecapacity to six cables in a butt configuration or twelve cables total. The 2181B Double Butt Adapter Kitcontains the fasteners necessary to assemble the splice case when the butt adapters are double stacked.The 2181 Kit can be installed at initial splicing or at reentry.

2.0 Specifications

- Maximum cable diameter: 1.0" (25 mm)- Minimum cable diameter: 0.4" (10 mm)- Maximum cable entry: 4 (2 per end)

with 2101 3 (4 per end)with (2) 2181 & 2181B 12 (6 per end)with (3) 2181 & 2181B 16 (8 per end)

3.0 Kit Contents3.01 2178 Contents

Qty.2178 Fiber Optic Splice Case/Cover & Base 1Sealing Washer Tree 4Sealing Plugs 2Key, Hex (Allen Wrench) 1Nut, Machine (10-32 3/8") 2Green Cable TY 2Blue Cable TY 2Clamp (Hose, .439/1.00) 22178 Universal Organizer/Adapter 1Sealing Cord 1Sealing Tape 1

Page 4: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

4

3.02 2180 Contents

Qty.Sealing Washer Tree 2Key, Hex (Allen Wrench) 1Green Cable TY 1Blue Cable TY 1Clamp (Hose, .439/1.00) 1Sealing Cord 1Sealing Tape 1

3.03 2181 Contents

Qty.Spacer Assembly 1Spacer Clamp Assembly 1Sealing Washer Tree 2Sealing Plugs 3Bolts, 3.5" 10Green Cable TY 1Blue Cable TY 1Clamp (Hose, .439/1.00) 1Key, Hex (Allen Wrench) 1Fillister Head Screws 2Sealing Cord 1Sealing Tape 1

3.04 2181B Contents

Qty.Fillister Head Screw, 4.95" (Screw Clamp Retention) 2Bolts, 4.95" 10

Page 5: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

5

3.05 2524-FT Splice Tray

Qty.Tray Base 1Buffer Tube Tubing 1 Rl.Fusion Splice Holder 2Dual Lock 3/4" x 3" 1

3.06 2185 Core Block Kit

Qty.4445 Sealant (will core block 4 cables) 1 BagGloves 1 Pr.Foam Tape 2 Rls.Tongue Depressor 1

3.07 Aerial Hanger Bracket

2182 2184

3.08 Additional Material Required:

3/4" (19 mm) Vinyl Tape2" (51 mm) Rubber TapeCable CleanerShield Bond ConnectorsSheath Scuff Material

3.09 Tools Required:

3/8" (9.5 mm) Socket Wrench Set1/2" (12.7 mm) Socket Wrench Set7/16" (11.1 mm) Socket Wrench Set9" Lineman PliersNeedle Nose PliersCable StripperSheath KnifeTape Measure

3.10 Optional Specialized Material Required:

#6 AWG Ground Braid or equivalent for isolated cable shields.AT&T unit splitter kit for unitube fiber optic cable.Spiral wrap used to protect express fibers with mid-span splicing and unitube cable.1" (25mm) vinyl tape and #69 Glass tape for sheath isolation for crossply and LXE cable only.RC-100 splice support for racking in vaults.1/2" x 2" bolts (2) with washers used with splice support system.1/2" x 2" self-tapping screws (2) with washers for fire retardant backboards.Threaded rod (1) 5 1/2" x 1/4" used with Siecor and Ditel trays with full volume and single butt adapter.Threaded rod (2) 7" x 1/4" used with Siecor and Ditel trays with full volume and double butt adapter.Split bolt for sheath isolation for crossply and LXE.

Page 6: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

6

4.0 Cable/Splice/Kit Matrix

4.01 The matrix below shows the number of cables that can be placed into a splice case and the components thatwould be required to build a new splice.

2181BDOUBLE BUTTADAPTER KIT

1

1

1

1

2181 BUTTADAPTER KIT

1

1

1

1

2

2

2

2

3

3

3

3

2180 CABLEADDITION KIT

1

2

2

3

4

5

5

6

7

8

8

9

10

11

2178FIBER OPTIC

SPLICECASE

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

# OFCABLES

2

3

4

5

6

7

8

9

10

11

12

13*

14*

15*

16*

Page 7: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

7

4.02 The following matrix describes the maximum number of splices that can be made to the maximum number ofcables that can be placed in a splice case:

MAJORCOMPONENTS *

2178

2178

21782181 (1)

21782181 (1)

21782181 (1)

21782181 (1)

21782181 (2)2181B (1)

21782181 (2)2181B (1)

21782181 (2)2181B (1)

21782181 (2)2181B (1)

21782181 (2)2181B (1)

21782181 (2)2181B (1)

21782181 (2)2181B (1)

BUTTSPLICE

x

x

x

x

x

x

IN-LINESPLICE

x

x

x

x

x

x

x

# OFCABLES *

2

2-4

2

3-4

3-4

5-8

2

3-4

5-6

2

3-4

5-8

9-12

# OF 24FIBER TRAYS

8

8

12

8

12

8

15

12

8

15

15

12

8

# OF FIBERSSPLICES

192

192

288

192

288

192

360

288

192

360

360

288

192

* See cable/splice/kit matrix in paragraph 4.01 for other components needed to complete thesplice.

Page 8: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

8

4.03 Tray Size Specifications:

Tray Size

Number ofFibrloksper Tray

3M/Brand Rex2118.375"

2524.42"

2524F.42"

ACT-200.375"

AT&T-UCSSM1.375"

DitelUST-1000UST-4000.32"

DitelUST-3000.42"

Northern TelecomNT6F3ICA.430"

PreformPN-8001041.375"

SiecorM67-031M67-041M67-045.22"

SiecorM67-070.430"

12

24

24

12

18

12

12

12

12

12

12

Standard3.46" Space

Available

9 trays

8 trays

8 trays

9 trays

9 trays

11 trays

8 trays

8 trays

9 trays

15 trays

8 trays

MaximumNumberofFibrloks

108

192

192

108

162

132

96

96

108

180

96

2178 with a 2181and No Cable4.96" Space

Available

13 trays

12 trays

12 trays

13 trays

13 trays

16 trays

11 trays

11 trays

13 trays

22 trays

11 trays

MaximumNumber ofFibrloks

156

288

288

156

234

192

132

132

156

264

132

Page 9: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

9

SECTION 1: 2178 SPLICE CASE INSTRUCTIONS

5.0 Cable Preparation

Caution: When removing cable sheathing, do not cut, kink, ordamage underlying layers. If damage occurs, cut backsheath components to adequately inspect and repair.

5.01 Remove 96" (2.43 m) of outer cable sheath (and shield or armor if present). Remove successive sheathlayers and wrappings to expose primary tube(s) protecting fibers. Stagger layers as recommended by cablemanufacturer or per standard practice.

5.02 Remove all cable grease. Clean all primary tube(s) and dielectric strands with approved cable cleaner.Cover all sharp edges with vinyl tape.

Note: Carefully follow health, safety and waste disposal instructions as given on Material Safety DataSheet or container label for cable cleaner solvent being used.

5.03 Trim any solid filler tubes and discard. Trim central strength members (if present) to 7" (178 mm) from sheathopenings.

5.04 Scuff and center 6" (152 mm) of each cableas shown.

5.05 Size and place washers on cable.

5.06 Slide two sealing washers down each cable. Use sealing washerswith smallest ID which will slide on the cable.

Note: If necessary, sealing washers can be split on washer markand placed on the cable. Place the cuts off set 180degrees.

6.0 Mid-Span Splice (Balloon Splice)

6.01 Mark the cable in the center of the stored slack.

6.02 Locate the approximate center of the mid-span opening and remove 18" (450 mm) of outer sheath, shield(if present), inner sheath and Kevlar wraps. Locate the reverse point of the buffer tube(s) oscillations.

Page 10: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

10

6.03 Remove 48" (1.2 m) of cable sheath (and shield, if present) from either side of the reverse point (60" frommid-point for LXE). Remove inner sheath to within 1/2" (13 mm) of the outer sheath ring cut.

Note: Removal of 48" (1.2 m) (60" for LXE) of outer cable sheath in both directions is required when thespliced fibers are not dedicated. The fibers to be spliced will be cut in the middle. This will allow96" (2.4 m) of stored slack available for re-splicing or bi-directional feed.

48" (1.2 m)

48" (1.2 m)

Buffer TubesSheath

96" (2.4 m)

6.04 Remove all cable grease. Clean all primary tube(s) and dielectric strands with approved cable cleaner.Cover all sharp edges with vinyl tape.

Note: Carefully follow health, safety, and waste disposal instructions as given on the Material Safety DataSheet or container label for cable solvent being used.

6.05 Trim any solid filler tubes and discard. Trim central strength members (if present) to 7" (178 mm) from sheathopenings.

6.06 Scuff 6" (152 mm) of each cable.

6.07 The buffer tubes to be spliced will be opened 2" (51 mm) from the cable end at the field side.

6.08 If the cable is a ribbon, unitube, or slotted core, loose tubes from aunit splitter kit will be placed over the fibers to be spliced forprotection.

6.09 Ribbon or non-buffer tube design cable will require 1/2" (13 mm)spiral wrap to protect the stored expressed fiber.

6.10 Fibers expressed, or not spliced, will be stored in the base underthe central members.

Page 11: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

11

7.0 Bonding for Shielded Cable

Note: Use caution when installing shield bond connector so underlying layers of cable are not damaged.

7.01 When splicing any standard, terneplate type, shielded fiber optic cable, install the 4460-D Shield BondConnector.

7.02 Prepare cable/tab 180 degrees from shield bond connector location and insert base.

Note: When a non-core wrap fiber optic cable is being used, use caution to not damage buffer tubeswhen inserting connector base.

7.03 Install the connector top over the stud and tighten firmly with oneof the securing nuts. Place the braid over the connector stud andsecure in place with the nut.

7.04 If double sheath, double shield fiber optic cable is being used,both outer shield and inner shield need to be bonded.

Leave 3/4" inner sheath and 3/4" of core wrap exposed and installtwo shield bond connectors 180 degrees apart per practice. Bothshield bond connectors need to be commoned with a bond strap.

7.05 When bonding LXE cable, the two LXE members must be placed in the two slots at the back of base unitafter it is installed. Twist LXE members together twice.

Page 12: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

12

7.06 When using steel reinforced crossply, and crossply with ribboncable, install the 4460-D per practice and twist all reinforcingmembers together and bring to one side.

8.04 Lay a 4" (102 mm) long piece of E-Z wrap lengthwise on theworkstation and position between foam collars. Wrap E-Z wrapedges around foam collars.

8.03 Separate buffer tube(s) and strength members. Build another foam collar by wrapping foam tape betweenbuffer tube(s) and strength members so the distance between collar outer edges is 4" (102 mm). Wrap twomore layers of foam tape around outside of buffer tube(s).

4" (102 mm)

8.02 Cut two 3/4" (19 mm) wide by 15" (381 mm) long strips of foamcollar tape. Build a foam collar by wrapping at least two layers offoam collar tape around cable sheath 1" (25 mm) from the end ofsheath.

1" (25 mm)

3/4" (19 mm)

8.0 Core Blocking

Note #1: This core blocking method is used on fiber cable design as of this practice issue date, exceptslotted core fiber cable.

Note #2: Core blocking of OFNR cable is not necessary.

Note #3: If sheath has not been scuffed, do before proceeding.

8.01 Non-Armored Application

Page 13: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

13

8.05 Cut corner of 4445 Sealant bag. Starting at opposite end, forcesealant out and fill area between foam collars.

Note: Carefully follow health, safety and disposal instructions asgiven on Material Safety Data Sheet or product label for4445 Sealant.

Note: Protective gloves should be worn during sealantdispensing and overwrapping steps.

8.06 Overwrap with at least two additional half-lapped layers of E-Zwrap.

8.07 Secure E-Z wrap by compressing foam collar ends with three half-lapped layers of highly stretched 3/4" (19 mm) vinyl tape.

8.08 Evenly work the 4445 Sealant between buffer tube(s) and strengthmembers.

8.09 Overwrap entire block with one half-lapped layer of highlystretched 3/4" (19 mm) vinyl tape.

8.10 Apply a compression wrap with two half-lapped layers of highlystretched 3/4" (19 mm) DR tape.

Page 14: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

14

8.14 Armored Application

Note: This procedure is the same for LXE, steel re-enforced crossply, crossply ribbon cable, loose buffertube and steel central member make up fiber optic cable.

Crossply LXE Loose Buffer Tube

8.15 Prepare cable for bonding the armor and strength members.

8.16 Cut stud of the shield bond connector flush with top nut and filesharp edges.

8.17 Cut two 3/4" (19 mm) wide by 15" (381 mm) long strips of foamcollar tape. Starting 1" (25 mm) behind shield bond connectorbuild foam collar with the foam collar tape, build collar highenough to accommodate the shield bond connector, bondingstraps and nuts.

1"(25 mm)

3/4"(19 mm)

8.11 Overwrap with one additional half-lapped layer of vinyl tape.

8.12 Repeat steps 8.02 thru 8.11 until all cables are blocked.

8.13 Secure the cables to the splice case per splice case practice.

Page 15: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

15

8.18 Separate buffer tube(s), strength member and bond members. Build another collar between buffer tube(s),strength members and bonding strap so distance between collar outer edges is 5" (127 mm). Wrap two morelayers of foam tape around outside of tubes.

5" (127 mm)

8.19 Lay a 5" (127 mm) long piece of E-Z wrap lengthwise on theworkstation and position between foam collars. Wrap E-Z wrapedges around foam collars.

8.20 Cut corner of 4445 Sealant bag. Starting at opposite end, forcesealant out and fill area between foam collars.

Note: Carefully follow health, safety and disposal instructions asgiven on Material Safety Data Sheet or product label for4445 Sealant.

Note: Protective gloves should be worn during sealantdispensing and overwrapping steps.

8.21 Overwrap with at least two additional half-lapped layers of E-Zwrap.

8.22 Secure E-Z wrap by compressing foam collar ends with three half-lapped highly stretched 3/4" (19 mm) vinyl tape.

8.23 Evenly work sealant between buffer tubes and strength members.

Page 16: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

16

8.24 Overwrap entire block with one half-lapped layer of highlystretched 3/4" (19 mm) vinyl tape.

8.25 Apply a compression wrap with two half-lapped layers of highlystretched 3/4" (19 mm) DR tape.

8.26 Overwrap with one additional half-lapped layer of vinyl tape.

8.27 Follow steps 8.15 thru 8.26 until all cables are blocked.

8.28 Secure the cables to the splice case per the splice case practice.

9.0 Sealing Washer Installation

9.01 Wrap each cable with two wraps of 2" wide DR Tape. Place wrapsbehind foam tape collar from core block.

9.02 Place the first sealing washer against the DR Tape. Build cableentrance seals by wrapping 1 1/2" (38 mm) sealing tape betweenwashers. Wrap each cable until sealing tape O.D. is flush with thewasher O.D. Slide second washer against sealing tape.

Page 17: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

17

9.03 Press cable seals onto cable entrance port(s).

9.04 Attach each cable to splice case by installing and tightening hoseclamps over previously wrapped DR Tape on the down brackets.Double sheath cable will have hose clamp tightened over metallictape previously placed on the cable instead of DR Tape.

9.05 Place cable ties outside of splice case. Install one large greencable tie on the "C.O. Cable" and trim. Install one large bluecable tie on the "Field Cable" and trim.

10.02 Place ground stud protector cap on ground studs.

10.03 If separate external grounding is not required, bond across spliceto either ground stud.

10.0 Grounding for Shielded Cable

10.01 Remove ground stud protectors. If bonding to central clamp isnot required, remove strap from external ground stud. Ifseparate external grounding is required, bond "C.O. Cable" and"Field Cable" directly to the closest ground stud.

Page 18: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

18

10.04 Ground isolation from the central block using AT&T crossply or LXE cable. This method will provide groundisolation plus strain relief protection.

a. The cables must enter the case in a butt configuration at the external ground stud end.

Note: When terminating OFNR cable, ground isolation is not necessary.

b. The crossply members must be twisted or spirally wound. The two LXE members are twisted togethertwice.

Note: The double tape method is required to assure ground isolation from the central clamp.

c. The final crossply and LXE member length should extend 3" (76 mm) beyond the central clamp.d. Starting 3" (76 mm) from the final cut end, wrap two strips 2" (51 mm) long of 1" (25mm) wide vinyl tape

lengthwise around the crossply members. Make sure the tape is overlapped and no metal is exposed.Each LXE member requires only one piece of vinyl tape.

e. Wrap a 2" (51 mm) length of #69 glass cloth backed tape over the vinyl tape. Two pieces of tape arerequired for crossply cable and one piece for each LXE member.

Note: The double tape method is required to assure ground isolation from the central clamp.

Page 19: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

19

f. The crossply members go under both central retention screws along the outer edge. The LXE membersgo under both sides of the two screws. Make sure the taped area is under the screws.

g. A split bolt clamp is required to join the crossply members to a number six or equivalent bond strap.Wrap vinyl tape over the bolt connection to protect against sharp edges or pinch points. Attach externalground stud.

11.0 Buffer Tube and Ribbon Cable Preparation

11.01 Unit splitter kits are required on all ribbon, unitube, or slotted core cable. Follow instructions supplied withthe unit splitter kits.

11.02 Gather all buffer tubes from "C.O. Cable" and install one small green cable tie approximately 36" (914 mm)from sheath end. Install one small blue cable tie on the "Field Cable" buffer tubes or ribbon cable.

Note: Spiral wrap or equivalent must be applied to unitube cable before applying cable tie.

11.03 Coil buffer tube, ribbon, unitube, or fibers bundles inside splicecase base. If using a splice tray that allows fiber entry at all fourcorners or two corners in the same end, the last 3/4 loop willallow tray movement for splicing away from splice case. Coilsshould be full splice case base length and width and should beunder the cable and central member.

11.04 When using the 2524-FT Fibrlok splice trays, or other trays thatallow fiber entry from the same corner, the buffer tubes, ribbon,unitube or slotted core fiber will need to route in the samedirection together. This is accomplished by having the fiber fromone cable pass in front of the central clamp and follow the routeof the other fiber. The 3M Fibrlok splice tray requires acounterclockwise direction. Follow supplied instructions withother splice trays to determine fiber route direction.

Page 20: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

20

11.05 Cut and position central member under central clamp retentionscrews. If necessary, remove insulation from central member.Using the supplied 7/32" hex key, firmly tighten each retentionscrew. If Kevlar is used for cable strain relief, wrap the Kevlarfibers twice around one central clamp retention screw andtighten the screw. Cut Kevlar fibers 1/2" (13 mm) from screw.

11.06 The crossply members go under both central clamp retention screws along the outer edge. The LXEmembers go under both sides of the two screws. Make sure the taped area is under the screws.

12.0 Universal Organizer Adapter

12.01 The universal organizer adapter is secured onto the studs located on the central clamp. Trays that will fit onthe organizer adapter are the 3M Fibrlok Tray, AT&T, UC Series, Ditel, Preform, and Siecor. The bottom trayis secured to the adapter by the adhesive-backed dual-lok pads. Additional trays are added by attaching tothe tray below or by using the supplied rod and wing nut.

AT&T Ribbon Cassette (for tray)PNUC-RR Splice OrganizerAT&T par #103921961

11.07 A split bolt clamp is required to join the crossply members to anumber six or equivalent bond strap. Wrap vinyl tape over thesplit bolt connection to protect against sharp edges or pinchpoints. Attach to external ground stud.

Page 21: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

21

13.0 Splice Trays and Fiber Splicing

13.01 2524-FT (Fusion and Fibrlok)

The Fibrlok 2524 Splice Organizer Tray stores up to 24 Fibrloksplices and/or 24 fusion splices and the respective buffer tubesand fibers. A 4" (102 mm) minimum bend diameter is maintainedin each tray. Also, the trays hinge together for individual trayaccess in a stack.

13.02 Prepare the cables and splice case for splicing.

Danger: Fiber ends and unmated connectors may emit INVISIBLE laser or LED radiation.

Avoid direct eye exposure to the beam. Do not inspect with magnifying instruments.Cap plugs should be kept on all unmated connectors.

Note: The following procedures must be followed prior to installing the 2524 Splice Organizer Tray.

13.03 Prepare the cables to be spliced per the company practice to expose 8 feet (2.4 m) of cable buffer tubes.

Clean the sealant from buffer tube(s) per company practice.

Note: Carefully follow health and safety information given on cleaning solvent container label or MaterialSafety Data Sheet.

13.04 If the cable is a ribbon, unitube or slotted core, loose tubes from a unit splitter kit will be placed over thefibers to be spliced for protection.

13.05 Secure the cables to the splice case per case practice.

13.06 Lay one complete coil of buffer tube(s) in the splice case in aCOUNTERCLOCKWISE direction. Buffer tubes should exit thesplice case in the corner where they will enter the splice trays.

13.07 Trim the buffer tubes (without cutting the fibers) to the middle ofthe splice case. Leave at least 75% of one coil buffer tubing intact.

13.08 Clean the grease from the fiber per company practice.

13.09 Cut the supplied tubing into 12" (305 mm) pieces.

Page 22: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

22

13.10 Slide a segment of tubing over the fibers until it contacts the buffertube end. No more than twelve 250 µm fibers or four 900 µmfibers should be placed into a tube.

13.11 Slide the segment of tubing over the buffer tube about 1" (25 mm)and secure with two wraps of vinyl tape.

13.12 Mount the universal organizer adapter in the splice case base.

13.13 Cut the Dual-Lok to fit the four flat pads on the tray bottom.Remove protective liner and adhere.

13.14 Center the tray over the adapter and press down to secure.

Page 23: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

23

13.15 To remove cover, unlatch and grasp either corner. Pull straightand rotate simultaneously until both hinges are disengaged.

13.16 Identify fibers to be spliced.

13.17 Lay the buffer tube ends over the channels. If tubes are too longto fit in channels, trim excess off. DO NOT CUT FIBERS.

13.18 Press the buffer tube into the channel to secure. The buffer tubeshould stop within 1/4" (6 mm) of the channel end.

13.19 Lay at least one complete loop of fiber from the first buffer tube onthe tray with the fiber ends crossing the front "CUT HERE" mark.

13.20 Now cut the fiber ends at the mark. Be sure to cut ONLY the fiberends.

13.21 Remove the cut fibers from the tray, but leave the buffer tubeinstalled.

13.22 Secure the buffer tube, from the second cable, which will now bespliced to those just cut.

Page 24: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

24

13.23 Lay at least 1 1/2 loops of fiber from the first buffer tube of thesecond cable on the tray with the fiber ends crossing the back"CUT HERE" mark.

13.24 Now cut the fiber ends at the mark. Be sure to cut ONLY the fiberends.

13.25 Remove the cut fibers from the tray, but leave the buffer tubeinstalled.

13.26 For remaining buffer tubes, repeat steps 13.15 through 13.25.

13.27 Store the first two fibers to be spliced under the tray tabs.

13.28 Remove the minimum length of fiber required to prepare and splitthe fibers.

13.29 Place the splicing tool in close proximity to the splice tray.Prepare and splice the first pair of fibers.

Note: If fusion splicing method is used, insert the fusion adapter(2524-F packed with 2524-FT) into splice tray.

Page 25: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

25

13.30 Lay the splice on top of the pocket that it will snap into. Place thefibers around the perimeter of the tray under the tray tabs. If 900micron fiber is being spliced to 250 micron fiber, place the 900micron fiber into the tray before placing splice in position. Thisremoves torsional load from the 900 micron fiber.

13.31 Prior to placing the splice into the pocket, observe how the splice lays in its relaxed state. Rotate the splicethrough the smallest possible angle. Snap splice into pocket cap side down.

13.32 For remaining fibers, repeat steps 13.27 through 13.31. Fillpockets in order.

13.33 Install and close tray cover making sure that all fibers are properlystored under the tray tabs.

13.35 Slide the post of the tray being added into the hole in the levelarm on the previously installed tray. (Back view shown).

13.34 Snap tray cover shut.

Page 26: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

26

13.36 Now slide the tray laterally (flexing the lever arm outward) enoughto allow the post to be inserted into the opposite lever arm hole.(Back view shown).

13.37 Lift the tray being added upwards approximately 1/2" (13 mm).Push in on the front snap of the installed tray and lower new traydown and over the snap.

13.38 For additional trays, repeat steps 13.35 through 13.37.

13.39 If trays are used in an aerial application, a wrap of vinyl tapearound entire stack between the front snaps and the cover snapsis recommended. This allows for reinforcement before sealingsplice case.

13.40 The label on the top of the tray cover allows for the identificationof splices and/or fiber count.

15.0 Splice Case Assembly

15.01 Seal splice case walls:

a. Lay sealing cord into channel along both sides of the splicecase base. Do not stretch sealing cord.

14.0 Splice Preparation

14.01 Open buffer tubes 1" (25 mm) from end of splice case base,exposing 40" (1.02 m) of bare fiber. Protect fibers from damage.

Note: Do not withdraw primary tubes coiled inside splice casebase.

14.02 Clean all cable grease from exposed fibers.

Page 27: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

27

b. Lay two strips of sealing cord 1 1/2" (38 mm) in lengthbetween the cable entrance ports on each end of the splicecase base, or one 3" (76 mm) length folded in half to fill thechannel.

15.02 Seal plug construction:

a. Select a plug for each vacant cable entrance port.

b. Wrap each plug with 1 1/2" (38 mm) sealing tape. Sealingtape O.D. should be flush with plug O.D. Do not overwrap.

c. Press seal plugs into each vacant cable entrance port.

15.03 Set splice case cover directly on top of the splice case base.

15.04 Turn all bolts until they have been threaded several completeturns into the nut inserts or until the cover rests on top of thesealing cord.

15.05 Tighten all bolts in numbered sequence. A torque wrench is not needed. If a torque wrench is used, do notexceed 20 Ft. Lbs. (240 in Lbs.).

Note: Do not use an air drive wrench.

9 6 2 84

751310

15.06 After five minutes, retighten all bolts on the splice case.

15.07 Flash test splice case with 10 psi maximum.

Page 28: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

28

16.0 Racking in Building Entrances and Vaults

16.01 Vertical Racking:

a. Determine height of splice.

b. Place a 1/2" (13 mm) bolt through racking that extends away from the wall.

c. The bottom of the 2178 is placed on the bolt so the groove on the base fits around the bolt.

d. Place a 1/2" (13 mm) bolt through the top groove to align with an opening.

e. Tighten bolts to prevent movement.

16.02 Horizontal Racking:

a. Determine height of splice.

b. Use RC-100 splice support clips.

Note: Follow instructions provided with packaging of RC-100 clips.

c. Insert clips in racking or unistrut.

d. Insert a standard manhole rack through the brackets.

e. Use 2" (51 mm) bolts to secure 2178 to installed rack.

f. Tighten bolts to prevent movement.

16.03 Fire Retardant Backboard:

a. Determine height of splice.

b. Screw two 1/2" x 2" (13 mm x 51 mm) bolts in backboard to secure 2178.

c. Can be stored vertical or horizontal.

Page 29: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

29

17.0 Splice Case Re-entry

17.01 Loosen the 10 bolts holding splice case halves together. Bolts should be completely unthreaded from nutinserts in splice case base.

17.02 Using these bolts, loosely screw one bolt into each of the fourthreaded corner inserts in the splice case cover.

17.03 Beginning with any corner, screw in bolt until the splice casehalves have been pried apart about 1/4" (6 mm). Repeat withthe other bolt on same end of the splice case.

Note: Do not pry apart with any tool. The splice case willseparate with this procedure.

17.04 Follow same procedure with the bolts on opposite end of thesplice case.

17.05 Repeat steps 17.03 and 17.04 until case halves can be easilyseparated by hand.

Note: If splice case is to be reassembled, all sealant must beremoved and cable entrance port seals reconstructed.

a. Remove old sealing cord from splice case channels. This is accomplished by pressing a small amount ofsealant into the channel and removed with a quick snap. The quick action will remove the old sealant.This is done to the cover and base.

Note: Do cleaning immediately after prying the splice case apart.

b. Plug removal - insert the small end of a terminal wrench in theplug opening and pry up. The plug will separate from the

splice case. Clean the plug and port area using themethod stated above.

c. Cable cleaning - remove the hose clamp from bracket to allowcable to be lifted away from the base. Grab the cable on bothsides of the sealing washers and pull up until the cable seal isbroken. Be careful not to damage the buffer or fibers that areworking. Clean the port area and cable using the methodstated above. If the sealing washers are damaged, use newwashers.

Page 30: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

30

SECTION 2: 2181 CABLE ADDITION KIT

18.0 Cable Addition Placement, Preparation and Installation (Butt Adapter)

18.01 Cables should be placed in cable entrance ports in a buttconfiguration for easier storage.

Note: Buffer tube retainers may be removed for installation of central clamp and additional trays.Replace buffer tube retainers after clamp and trays are installed.

a. Remove existing tray(s) and set aside. Remove the twofillister head screws holding the central clamp to the splicecase base.

18.02 Cable preparation - (See Section 5.0).

18.03 Stack Central Clamps

b. Place the second level central clamp directly on top of splicecase base central clamp and secure the two fillister headscrews supplied with the 2181 kit.

18.04 Bonding for Shielded Cable - (See Section 7.0)

18.05 Core Blocking - (See Section 8.0).

18.06 Grounding for Shielded Cable - (See Section 10.0).

18.07 Sealing Washer Installation (See Section 9.0 through 9.05).

19.0 Butt Adapter 1 Installation

19.01 For the single butt adapter splice case, replace all ten 2" (51 mm) bolts inserted in the splice case coverwith the ten 3 1/2" (89 mm) bolts supplied with the 2181 kit.

Page 31: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

31

20.0 Splice Case Assembly with One Adapter

20.01 Seal splice case walls:

a. Lay sealing cord into channel along both sides of the splicecase base. Do not stretch sealing cord.

b. Lay two strips of sealing cord 1 1/2" (38 mm) in lengthbetween the cable entrance ports on each end of the splicecase base, or one 3" (76 mm) length folded in half to fill thechannel.

c. Press seal plugs into each vacant cable entrance port.

20.03 Set butt adapter 1 (flange side down) as is on top of splice casebase.

Note: These steps are done to seat cord between splice case andbutt adapter.

20.04 Set cover directly over butt adapter 1.

20.02 Seal plug construction:

a. Select a plug for each vacant cable entrance port.

b. Wrap each plug three times with 1 1/2" (38 mm) sealing tape. Sealing tape OD should be flush with plugOD. Both ends of tape should be feathered to prevent leak paths. Do not overwrap.

Page 32: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

32

20.05 Tighten all bolts in numbered sequence. A torque wrench is notneeded. If a torque wrench is used, do not exceed 20 Ft. Lbs.(240 in Lbs.).

Note: Do not use an air drive wrench.

10 3 1 5 7

84269

20.06 Follow steps 20.01 through 20.04 to seal butt adapter to cover.

20.07 After five minutes, retighten all bolts on the splice case.

20.08 Flash test splice case with 10 psi maximum.

21.0 Cable Addition Placement, Preparation and Installation (Two Adapters)

21.01 For the double butt adapter splice case, replace all ten 2" (51 mm) bolts inserted in the splice case coverwith the ten 4.95" (126 mm) bolts supplied with the 2181B kit.

21.02 Cables should be placed in cable entrance port in a buttconfiguration for easier storage.

21.03 Cable preparation - (See Section 5.0).

21.04 Stack Central Clamps

Note: Buffer tube retainers may be removed for installation of central clamp and additional trays.Replace buffer tube retainers after clamp and trays are installed.

a. Remove the splice trays from the central clamp or universaladapter and set aside. If the universal adapter is used, it mustbe removed from the central clamp. Remove the two fillisterhead screws holding the central clamp to the splice casebase.

b. Place the third level central clamp directly on top of thesecond level central clamps and secure the two fillister headscrews supplied with the 2181B kit.

Page 33: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

33

21.05 Bonding for Shielded Cable - (See Section 7.0)

21.06 Core Blocking - (See Section 8.0).

21.07 Grounding for Shielded Cable - (See Section 10.0).

21.08 Follow instructions in Section 15.0 per adapter installed.

22.0 Butt Adapter 2 Installation

22.01 For the double butt adapter splice case, replace all ten 2" (51 mm) bolts inserted in the cover with the ten5" (103 mm) bolts supplied with the 2181B kit.

23.0 Splice Case Assembly with Two Adapters

23.01 Seal splice case walls:

a. Lay sealing cord into channel along both sides of the splicecase base. Do not stretch sealing cord.

b. Lay two strips of sealing cord 1 1/2" (38 mm) in lengthbetween the cable entrance ports on each end of the splicecase base, or one 3" (76 mm) length folded in half to fill thechannel.

23.02 Seal plug construction:

a. Select a plug for each vacant cable entrance port.

b. Wrap each plug three times with 1 1/2" (38 mm) sealing tape. Sealing tape OD should be flush with plugOD. Both ends of tape should be feathered to prevent leak paths. Do not overwrap.

c. Press seal plugs into each vacant cable entrance port.

23.03 Set butt adapter 2 (flange side down) directly on top of buttadapter and splice case base.

Note: These steps are done to seat cord between splice case andbutt adapter.

Note: Follow Section 20.0 to build splice case base and first buttadapter.

Page 34: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

34

23.04 Set cover directly over butt adapter 2.

24.0 Splice Case Re-entry with Butt Adapters

24.01 Loosen the 10 bolts holding splice case halves together. Bolts should be completely unthreaded from nutinserts in splice case base.

Note: See label on end of splice case.

24.02 Using these bolts, loosely screw one bolt into each of the four threaded corner inserts in the splice casecover.

23.06 Follow steps 23.01 through 23.04 to seal butt adapter.

23.07 After five minutes, retighten all bolts on the splice case.

23.08 Flash test splice case with 10 psi maximum.

24.03 Beginning with any corner, screw in bolt until the splice casecover has been pried from butt adapter about 1/4" (6 mm).Repeat with the other bolt on same end of the splice case.

24.04 Follow same procedure with the bolts on opposite end of the splice case.

24.05 Repeat steps 27.03 and 27.04 until case cover can be easily separated from butt adapter by hand.

23.05 Tighten all bolts in numbered sequence. A torque wrench is notneeded. If a torque wrench is used, do not exceed 20 Ft. Lbs.(240 in Lbs.).

Note: Do not use an air drive wrench.

10 3 1 5 7

84269

Page 35: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

35

24.06 Remove the four corner inserts on exposed side of butt adapterby prying out with a screwdriver.

Note: Do not discard corner inserts. Inserts must be replaced inbutt adapter before reassembly.

24.07 Loosely screw one bolt into each of the four threaded corner inserts of the butt adapter. The threadedcorner inserts are located directly beneath the previously removed corner inserts.

24.08 For the SINGLE BUTT adapter splice case repeat steps 27.03 through 27.05 to separate butt adapter 1from splice case base.

24.09 For DOUBLE BUTT adapter splice case repeat steps 27.06 through 27.08 to separate butt adapter 2 frombutt adapter 1.

Note: If splice case is to be reassembled, old sealant must be removed and cable entrance port sealsreconstructed.

Page 36: Instructions 2178 Fiber Optic Splice Case...3 1.0 General The 3M 2178 Fiber Optic Splice Case is used in underground, aerial, building entrance, and pedestal applications. The splice

1992 3M Litho in U.S.A.

3M Telecom Systems Group

6801 River Place Blvd.Austin, TX 78726-9000

34-7029-6387-6

Important Notice

All statements, technical information and recommendations related to the Seller's products are based on information believed tobe reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determinethe suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use.

Any statements or recommendations of the Seller which are not contained in the Seller's current publications shall have no forceor effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein aremade in lieu of all warranties, express or implied, including but not limited to the implied warranties of merchantability and fitnessfor a particular purpose which warranties are hereby expressly disclaimed.