Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat...

16
speedfitUFH.co.uk For model: JGTRV Instruction Manual

Transcript of Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat...

Page 1: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

speedfitUFH.co.uk

For model:

JGTRV

Instruction Manual

Page 2: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Contents

JGTRV

2x AA Batteries

Instruction Manual

speedfitUFH.co.uk

For model:

JGTRV

Instruction Manual

Icons used in this manual:

Safety

Important info

Your benefit

Instruction manual:

• Box contents

• Introduction

• Product compliance and Safety information

• Installation

• User interface

• Status/LED indication

• Installer notes

For latest PDF Instruction Manual please go to speedfitUFH.co.uk

02 Wireless TRV Instruction Manual

Adapter

Box contents:

Page 3: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Introduction. Thank you for purchasing the Speedfit Aura Wireless TRV (JGTRV). The JGTRV simply replaces the passive head supplied with a standard Thermostatic Radiator Valve (TRV). The JGTRV must be used with a JGSTATW1 or JGSTATW2 Wireless Thermostat and a JGCO Wireless coordinator (all sold separately). The JGTRV can be used with the JGBR Wireless Boiler Receiver (configured to RX1) and other Aura wireless products (see below).

Product Compliance. This product is CE compliant and meets the following EC Directives: RoHS2 directive 2011/65/EU, Electro-Magnetic Compatibility directive 2004/108/EC and Low voltage directive 2006/95/EC.

Safety Information. Use in accordance with the regulations. The Aura JGTRV is to be used for room control in buildings.

Installation. This accessory must be fitted by a competent person, and installation must comply with the guidance, standards and regulations applicable to the location where the product is installed. Failure to comply with the relevant standards could lead to prosecution.

JGSTATW1/JGSTATW2

Thermostat (Required)

Wiring Centre JGWCWJGBR(Optional)

JGCO(Required)

03speedfitUFH.co.uk

Product Compliance & Safety Information

Page 4: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

To provide the best level of system control, we recommend that the JGTRV is installed with a JGBR Boiler Receiver (configured to RX1). This enables the Wireless Thermostats in the system to switch the boiler on/off whilst also opening/closing the radiator valves.

+

Only 3 TRV’s can be paried to a JGSTATW1/JGSTATW2.

The JGTRV is modulating which means it can regulate the flow-rate through the valve. A paired Wireless Thermostat increases/decreases the flow-rate through the valve based on the difference between the set temperature and the room temperature.

04 Wireless TRV Instruction Manual

System Overview

Page 5: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Installation - General

Detach top housing by pressing a flat screwdriver into the slot as shown above.

Remove the battery cap.

Insert the batteries and replace the battery cap.Please note correct battery orientation.

Gently place the top housing onto the bottom housing. Note correct orientation.

Optional adapter.Ready to be fitted to the radiator valve. Note: The LED will flash green and then red before eventually changing to solid red.

1 2 3

4 5

05speedfitUFH.co.uk

Page 6: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Place the TRV over the radiator valve.

Tighten the TRV (finger tight) to the radiator valve.

Check that LED is solid red.

Press any button to commence adaptive mode.

Adaptation to the valve is complete once all noise and LED activity has ceased. If LED continues to flash refer to page 11.

The unit is now ready for pairing to the Aura thermostat.

It is recommended that pairing is done on a room by room basis.

06 Wireless TRV Instruction Manual

Installation - General

6 7 8

9 10 11

Page 7: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

1

2

3

System setup checklist

The Wireless Coordinator must be in Pairing Mode.Before starting the pairing, make sure the light is flashing on the Coordinator by holding the button for 5 seconds. Please refer to the JGCO Wireless Coordinator Instruction Manual.

Ensure that the thermostat is powered up and ready for configuration and pairing.Please refer to pages 32 and 37 in the Wireless Thermostat Instruction Manual.

If you are using the optional JGBR Boiler Receiver configured for remote boiler switching, ensure this has been powered up and the red flashing LED has gone steady.Please refer to Boiler Receiver Instruction Manual.

07speedfitUFH.co.uk

Installation - Pairing

Page 8: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Press and hold the pairing button for 5 seconds.

Once the red LED starts flashing go to page 37 in JGSTATW1/JGSTATW2 Instruction Manual.

When pairing is successful with the JGSTATW1/JGSTATW2 thermostat the LED will go out.

08 Wireless TRV Instruction Manual

1

2

Installation - Pairing

Page 9: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

LED Indication

Pairing Button

Manual open/status indication

Manual close/status indication

09speedfitUFH.co.uk

User Interface

Page 10: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

LED flashes red twice. The valve is manually closed.

LED flashes green twice. The valve is manually open.

If wireless link is lost error code **-07 will show on the connected thermostat.

Manual Mode (See page 12)

10 Wireless TRV Instruction Manual

Status Indication

Short press on either button will show status.

Page 11: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Low BatteryIf the battery low, the red light will flash three times every ten seconds. When replacing batteries follow steps 1 to 9 on page 5 and 6.

Installation ErrorIf there is an error in the installation the TRV LED will flash Red / Green alternately. Please remove the TRV from the radiator valve and repeat the installation steps on page 6.

Low battery in the radiator valve will also be shown as error code **-22 on the connected thermostat.

11speedfitUFH.co.uk

LED Indication

Page 12: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Long press to manually open TRV.

LED flashes green once and then goes out. To check status refer to page 10.

To remove the JGTRV from auto mode, follow steps below.

Long press to manually close TRV.

LED flashes red once and then goes out. To check status refer to previous page.

Short press to return to Auto mode. Red LED will flash once to confirm that the unit is in AUTO.

12 Wireless TRV Instruction Manual

Manual Override

Page 13: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

Model JGTRV

Type Hydraulic Radiator Valve DC Motor M30 x 1.5

Input 3 push buttons. Auto/Open/Close/Pair

LED Indicator Bi-Colour, Red/Green

Valve Adaptation Automatic

Power Source 2 x AA Batteries

Battery Life 12 Months

Control Method Modulating

Communication Zigbee - 2.4GHz

Operating Temperature 0ºC to 50ºC

Storage Temperature -20ºC to 60ºC

13speedfitUFH.co.uk

Technical Detail

Page 14: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

14 Wireless TRV Instruction Manual

Installer Notes

Page 15: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

15speedfitUFH.co.uk

Installer Notes

DisclaimerCustomers that choose to operate their heating remotely using JG Aura Range technology via their personal computer, tablet or smart phone device(s) will be entering into a contract with Salus Controls plc (“Salus”), which is a third party supplier of the software. John Guest Ltd and affiliates within the John Guest group of companies from time to time (the “John Guest Group”) make no representations or warranties of any kind about the reliability or suitability of the software or applications provided by Salus. The John Guest Group disclaims liability (excluding liability for death and personal injury resulting from negligence) for any loss or damage caused by the software provided to customers by Salus. Any agreement entered into with Salus is therefore strictly at your own risk.

Page 16: Instruction Manual - John Guest€¦ · Coordinator Instruction Manual. Ensure that the thermostat is powered up and ready for configuration and pairing. Please refer to pages 32

John Guest Speedfit LimitedHorton Road, West Drayton, Middlesex UB7 8JL, England.

Tel: 01895 449233 Fax: 01895 420321speedfitUFH.co.ukTechnical Help Desk: 01895 425333

The above namestyles are all trademarks of John Guest International Limited.

© John Guest International Limited 2016. All rights reserved.

Z2105/424/1016

, and