Installation Manual - The Fireplace Showcase

24
1 7080-131B March 14, 2014 MT. VERNON PELLET STOVE E2 Model(s): MTV-E2-CSB MTV-E2-MBK MTV-E2-PFT MTV-E2-PDB MTV-E2-PBK MTV-E2-PMH Installation Manual Installation & Appliance Set-Up INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. NOTICE: DO NOT DISCARD THIS MANUAL O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace. Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. WARNING If the information in these instruc- tions is not followed exactly, a fire could result causing property damage, personal injury, or death. • Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. • Do not overfire - If heater or chimney con- nector glows, you are overfiring. Overfiring will void your warranty. • Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire. CAUTION Tested and approved for wood pellets only WARNING NOTE To obtain a French translation of this manual, please contact your dealer or visit www.quadrafire.com Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.quadrafire.com CAUTION Check building codes prior to installation. Installation MUST comply with local, regional, state and na- tional codes and regulations. Consult local building, fire officials or authorities having juris- diction about restrictions, installation inspection, and permits. Please read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death. 061-S-83-2

Transcript of Installation Manual - The Fireplace Showcase

Page 1: Installation Manual - The Fireplace Showcase

1 7080-131B March 14, 2014

MT. VERNON PELLET STOVE E2

Model(s):MTV-E2-CSBMTV-E2-MBKMTV-E2-PFTMTV-E2-PDBMTV-E2-PBKMTV-E2-PMH

Installation ManualInstallation & Appliance Set-Up

INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.

NOTICE: DO NOT DISCARD THIS MANUAL

O-T LTested and Listed by

PortlandOregon USA

OMNI-Test Laboratories, Inc.C US

HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.• Do not touch glass until it is cooled• NEVER allow children to touch glass• Keep children away• CAREFULLY SUPERVISE children in same room as

fireplace.• Alert children and adults to hazards of high temperatures• High temperatures may ignite clothing or other

flammablematerials.• Keep clothing, furniture, draperies andother flammable

materials away.

WARNING

If the information in these instruc-tions is not followed exactly, a firecouldresultcausingpropertydamage, personal injury, or death.

• Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthis or any other appliance.

• Donotoverfire-Ifheaterorchimneycon-nectorglows,youareoverfiring.Overfiringwillvoidyourwarranty.

• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.

CAUTIONTestedandapprovedforwoodpelletsonly

WARNING

NOTEToobtainaFrenchtranslationofthismanual,pleasecontactyourdealerorvisitwww.quadrafire.com

Pourobtenirunetraductionfrançaisedecemanuel,s’ilvousplaîtcontactervotrerevendeurouvisitezwww.quadrafire.com

CAUTIONCheckbuildingcodespriortoinstallation.• InstallationMUSTcomplywithlocal,regional,stateandna-

tional codes and regulations.• Consultlocalbuilding,fireofficialsorauthoritieshavingjuris-

dictionaboutrestrictions,installationinspection,andpermits.

Pleasereadthisentiremanualbeforeinstallationanduseofthispelletfuel-burningroomheater.Failuretofollowtheseinstructionscouldresultinpropertydamage,bodilyinjuryorevendeath.

061-S-83-2

Page 2: Installation Manual - The Fireplace Showcase

2 7080-131B March 14, 2014

MT VERNON E2

TABLE OF CONTENTS

Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcouldresultindeathorseriousinjury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.• NOTICE: Indicates practices which may cause damage to the appliance or to property.

Quadra-Fire is a registered trademark of Hearth & Home Technologies.

1 Important Safety Information ............ 3A.ApplianceCertification ......................................................3B.BTU&EfficiencySpecifications........................................3C.GlassSpecifications .........................................................3D. Electrical Rating................................................................3E.MobileHomeApproved .................................................... 3F.Non-CombustibleMaterials ................................................3G.CombustibleMaterials .......................................................3

2 Getting Started ................................... 4A. Design, Installation & Location Considerations ..........................4B. Remote Thermostat Location ............................................5C. Tools And Supplies Needed ..............................................5D. Inspect Appliance and Components .................................5E. Install Checklist ..................................................................6

3 Dimensions and Clearances ............. 7A. Appliance Dimensions ......................................................7B.ClearancestoCombustibles(US&Canada) ....................8C.HearthPadRequirements(US&Canada)........................8D.Alcove....... .........................................................................9

4 Vent Information ............................... 10A.VentingTerminationMinimumRequirements ...................10B.AvoidingSmokeandOdors ...............................................11C.NegativePressure .....................................................12D. Draft ........ .........................................................................12E. Chimney and Exhaust Connection ..................................12F. EquivalentFeetofPipe ....................................................13G. Pipe Selection Chart ........................................................13

5 Venting Systems .............................. 14A. Through The Wall .............................................................14B. Vertical into Existing Class A Chimney .............................15C. Through The Wall & Vertical - Exterior ..............................15D. Vertical - Interior - Typical Installation ................................15E. Masonry ............................................................................16F. Alternate Masonry .............................................................16

6 Appliance Set-Up ............................. 17A.LegLevelingSystem .......................................................17B.OutsideAirKitInstructions................................................17C. Top Vent Adapter Installation ............................................18D. Rear Vent & Rear Vent to Top Vent Adapter Installation ...18E.OptionalLogSetPlacementInstructions..........................19F. Remote Thermostat Installation .......................................20G. Power Cord .......................................................................20

7 Mobile Home Installation ................. 218 Accessory List ................................. 22

Page 3: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 3

MT VERNON E2

TheQuadra-FireMt.VernonE2PelletStovemeetstheU.S.Envi-ronmentalProtectionAgency’s1990particulateemissionstandards.

1 Important Safety Information

NOTE:Hearth&HomeTechnologies,manufacturerofthisappliance,reservestherighttoalteritsproducts,theirspecificationsand/orpricewithoutnotice.

Improper installation, adjustment, alteration, service ormaintenancecancauseinjuryorpropertydamage.Forassistanceoradditionalinformation,consultaqualifiedinstaller,serviceagencyoryourdealer.

• Installationanduseofanydamagedappliance.• Modificationoftheappliance.• Installation other than as instructed by Hearth & Home

Technologies.• Installationand/oruseofanycomponentpartnotapprovedby

Hearth & Home Technologies.• Operatingappliancewithoutfullyassemblingallcomponents.• Operatingappliancewithoutlegsattached(ifsuppliedwithunit).• DoNOTOverfire- Ifapplianceorchimneyconnectorglows,

youareoverfiring.Anysuchactionthatmaycauseafirehazard.

WARNING

Fire Risk.

Hearth & Home Technologies disclaims any responsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:

• Thestructuralintegrityofthemobilehomefloor,ceil-ing,andwallsmustbemaintained.

• Theappliancemustbeproperlygroundedtotheframeof themobile home and use only Listed pellet ventClass “L” or “PL” connector pipe.

• OutsideAirKit,partOAK-3mustbeinstalledinamo-bilehomeinstallation.

F. Non-Combustible MaterialsMaterialwhichwillnotigniteandburn,composedofanycombinationofthefollowing: - Steel - Plaster - Brick - Iron - Concrete - Tile - Glass - SlateMaterials reported as passing ASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C.

G. Combustible MaterialsMaterialmadeof/orsurfacedwithanyofthefollowingma-terials: - Wood - Compressed Paper -PlantFibers -Plastic -Plywood/OSB -SheetRock(drywall)Anymaterialthatcanigniteandburn:flameproofedornot,plastered or un-plastered.

*BTUwillvary,dependingonthetypeoffuelyouuseinyourappliance.ConsultyourQuadra-Firedealerforbestresults.

C.GlassSpecificationsThisstoveisequippedwith5mmceramicglass.Replaceglass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

D. Electrical Rating115 VAC, 60 Hz, Start 2.9 Amps, Run 2.45 Amps

E. Mobile Home Approved • Thisappliance isapproved formobilehome installa-

tions when not installed in a sleeping room and when anoutsidecombustionairinletisprovided.

Model Mt.VernonPelletStoveE2Laboratory OMNITestLaboratories,Inc.Report No. 061-S-83-2Type SolidFuelRoomHeater/PelletFuel

Burning TypeStandard ASTM E1509-12, ULC S627-00 and

(UM)84-HUD,MobileHomeApproved.FCC Complies with Part 15 of FCC Rules.

Operationissubjecttothefollowingtwoconditions:(1)thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycause undesired operation.

A.ApplianceCertification

NOTICE: This installation must conform with local codes. In theabsenceoflocalcodesyoumustcomplywiththeASTM E1509-12, ULC S627-00, (UM) 84-HUD and ULC/ORD-C-1482.

B.BTU&EfficiencySpecificationsEPACertified: 1.7 grams per hour low

2.7gramsweightedaverage

Efficiency(LHV): up to 87%

BTU Input: 18,000 to 52,500

BTU Output: 13,800 to 37,600

Heating Capacity:upto3,000sqftdependingon climate zone

Vent Size: 3inches‘L’or‘PL’

Fuel: Wood Pellets

Shipping Weight: 440lbs

Page 4: Installation Manual - The Fireplace Showcase

4 7080-131B March 14, 2014

MT VERNON E2

Install Guide2 Getting Started

Marginal Location:• Below peak

Location NOT recommended:• Not the highest point of the roof• Wind loading possible

Multi-level Roofs

Windward

Leeward

Recommended:Outside Air Intakeon windward side

NOT recommended:Outside Air Intakeon leeward side

Recommended Location:• Above peak

Recommended:• Insulated exterior chase

in cooler climates

Recommended Location:• Above peak• Inside heated space

Location NOT recommended:• Too close to tree• Below adjacent structure• Lower roof line• Avoid outside wall

Marginal Location:• Wind loading possible

Figure 4.1

A. Design, Installation & Location Considerations 1. Appliance Location

NOTICE: Checkbuildingcodespriortoinstallation.• InstallationMUSTcomplywithlocal,regional,stateand

national codes and regulations.• Consult insurance carrier, local building inspector, fire

officialsorauthoritieshavingjurisdictionoverrestrictions,installation inspection and permits.

It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, beforeactuallybeginningtheinstallation.Locationoftheapplianceand chimney will affect performance.Considerationmustbegivento:• Safety,convenience,trafficflow• Placementofthe chimney and chimney connector and to

minimize the use of chimney offsets. • Placetheappliancewheretherewillbeaclearpassage

foraListedchimneythroughtheceilingandroof(vertical)orthroughexteriorwall(horizontal).

• Installingtherequiredoutsideairkitwillaffectthelocationoftheventtermination.

Whenlocatingventandventingtermination,theidealloca-tionistoventaboverooflinewhenpossible.Thisminimizesthe affects of wind loading.

Since pellet exhaust can contain ash, soot or sparks, you mustconsiderthelocationof:• Windows• AirIntakes• AirConditioner• Overhang,soffits,porchroofs,adjacentwalls• Landscaping,vegetation• Horizontalorverticalventtermination2. Floor SupportThe supporting floor under the appliancemust be able tohandle the weight of the appliance, fuel load and the weight of the chimney.Ensure that your floor will support these weights prior toinstallation. Add sufficient additional support tomeet thisweight requirementprior to installation. Theweightof theapplianceis440lbs.withafullloadoffuelthemaxweightis520lbs.

WARNINGRisk of Fire.Damaged parts could impair safe operation. Do NOT installdamaged,incompleteorsubstitutecomponents.

Page 5: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 5

MT VERNON E2

• Installation and use of any damaged appliance.

•Modificationoftheappliance.• InstallationotherthanasinstructedbyHearth&Home

Technologies.• Installation and/or use of any component part notapprovedbyHearth&HomeTechnologies.

• Operating appliance without fully assembling allcomponents.

• Operatingappliancewithoutlegsattached(ifsuppliedwithunit).

• DoNOTOverfireOranysuchactionthatmaycauseafirehazard.

WARNINGHearth & Home Technologies disclaims any responsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:

Reciprocating Saw Channel LocksHammer PhillipsScrewdriverTapeMeasure PlumbLine1/4”Self-TappingScrews FramingMaterialHi-tempCaulkingMaterial GlovesSafetyGlasses FramingSquareElectricDrill&Bits(1/4”) Level

Mayalsoneed:Vent Support Straps Venting Paint

Tools and building supplies normally required for installation, unless installing into an existing masonryfireplace:

C. Tools And Supplies Needed

B. Remote Thermostat LocationThe remote thermostat’slocationwillhavesomeaffect on the appliance’soperation.• When located close to the appliance, itmay require a

slightly higher temperature setting to keep the rest of the housecomfortable.

• When locatedinanadjacentroomoronadifferentfloorlevel,youwillnoticehighertemperatures near the appli-ance.

CAUTION! Theremotethermostatisanintegralpartoftheappliance. No other wall control or thermostat can be substituted.

D. Inspect Appliance and Components • Opentheapplianceandremoveallthepartsandarticles

packed inside the Component Pack. Inspect all the parts and glass for shipping damage.

• Reporttoyourdealeranypartsdamagedinshipment.

• Alllabelshavebeenremovedfromtheglassdoor.

• Platedsurfaceshavebeenwipedcleanwithasoftcloth,ifapplicable.

• Readalltheinstructionsbeforestartingtheinstallation.Follow these instructions carefully during the installationtoensuremaximumsafetyandbenefit.

• Followpipemanufacturerinstructionsforinstallationand air clearance requirements.

**HHTrecommendsarangelimitof20feetforbestperfor-mance

MODE/SET

Risk of Fire! Damaged parts could impair safe operation. DoNOTinstalldamaged,incompleteorsubstitutecomponents.

WARNING

Page 6: Installation Manual - The Fireplace Showcase

6 7080-131B March 14, 2014

MT VERNON E2

ATTENTION INSTALLER:Follow this Standard Work Checklist

Thisstandardworkchecklististobeusedbytheinstallerinconjunctionwith,notinsteadof,theinstructionscontainedinthisinstallationmanual.

Customer: Date Installed: Lot/Address: Location of Fireplace: Installer: Dealer/ Distributor Phone #: Serial #: Model (circle one): MTV-E2-MBK MTV-E2-CSB MTV-E2-PFT MTV-E2-PDB MTV-E2-PBK MTV-E2-PMH

WARNING! Risk of Fire or Explosion! Failuretoinstallfireplaceaccordingtotheseinstructionscanleadtoafireorexplosion.

Hearth & Home Technologies recommends the following:•Photographingtheinstallationandcopyingthischecklistforyourfile.•Thatthischecklistremainvisibleatalltimesonthefireplaceuntiltheinstallationiscomplete.

Comments: Furtherdescriptionoftheissues,whoisresponsible(Installer/Builder/OtherTrades,etc.)andcorrectiveactionneeded:Commentscommunicatedtopartyresponsible by on (Builder/Gen.Contractor) (Installer)(Date)

Part#4017-254•RevB•01/29/13

E. Install Checklist

Appliance Install Requirednon-combustiblefloorprotection(Pg.9)Verifiedclearancetocombustible(Pg.8)Unitisleveledandsecured(Pg.18)

Venting/Chimney Section 4 (Pg. 12)VentingconfigurationcomplieswithdiagramsVenting installed, sealed and secured in place with proper clearanceExteriorwall/roofflashinginstalledandsealedTerminations installed and sealedOAKinstalledandsealed(ifneeded)(Pg.16&17)

Electrical120VACunswitchedpowerprovidedtotheappliance(Pg.21)

Appliance Setup Section 5 (Pg. 17)AllpackagingandprotectivematerialsremovedAccessories installed properlyStartedapplianceandverifiedthatallmotorsandblowersoperateastheshouldManualbagandallofitscontentsareremovedfrominside/underthefireplaceandgiventothepartyresponsibleforuseandoperation.

YES IF NO, WHY?

Page 7: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 7

MT VERNON E2

Figure 7.4 - Front View

Figure 7.1 - Top View with Top Vent Adapterand 3 to 6 in (76-152mm) Adapter

Figure 7.5 - Side View

Figure 7.2 - Side View with Top Vent Adapter and 3 to 6 in (76-152mm) Offset Adapter.

31-1/16[788]

29-3/16[741]

q

5-13/16[147]

2-9/16[65]

3-13/16[97]

14-1/16[357]

28-1/8 [714]

32-5/16[821]

28-7/16 [722]

19-9/16[497]

20 [508]

28-3/4 [730]

26-7/8 [683]

18-1/2 [470]

3-5/8[93]

q

Figure 7.3 - Top View

3 Dimensions and ClearancesA. Appliance Dimensions

Page 8: Installation Manual - The Fireplace Showcase

8 7080-131B March 14, 2014

MT VERNON E2

Straight Back Against Wall Inches MillimetersA Back Wall to Appliance 2 51B Side Wall to Appliance 6 152

Corner Installation Inches MillimetersC Walls to Appliance 2 51

Vertical Installation Inches MillimetersD Back Wall to Flue Pipe 3 76E Side Wall to Appliance 6 152F Back Wall to Appliance 8 203

Installations with:3 to 3 inch Top Vent Adapter and3 to 6 inch Offset Adapter Kit

Corner Installation Inches MillimetersG Side Wall to Flue Pipe 3 76

Alcove Installation Inches MillimetersMinimumAlcoveHeight 43 1092MinimumAlcoveSideWall 6 152MinimumAlcoveWidth 40 1016MaximumAlcoveDepth 36 914

D

E

F

A

B

*L Exception for Horizontal Installations:USA INSTALLATIONS: A non-combustible floor protec-tion is recommended extendingbeneaththefluepipewheninstalled with horizontal venting or under the Top VentAdapterwithverticalinstallation.CANADA INSTALLATIONS: A non-combustiblefloorpro-tection extendingbeneaththefluepipeis required with hor-izontalventingorunder theTopVentAdapterwithverticalinstallation.

Must extend 2 inches (51mm) beyond each side of pipe (shaded area)

NOTE:• IllustrationsreflecttypicalinstallationsandareFOR

DESIGNPURPOSESONLY.• Illustrations/diagramsarenotdrawntoscale.• Actualinstallationmayvaryduetoindividualdesign

preference.

C

C

G

G

L*

K K

M

Use a non-combustible floor protector, extending beneathappliance and to the front, sides and rear as indicated. Mea-sure front distance “M” from the surface of the glass door.

Hearth Pad Requirements Inches MillimetersK Sides 2 200L* Back 2 200M Front 6 450

B. Clearances to Combustibles (US & Canada) C. Hearth Pad Requirements (US & Canada)

Fire Risk.Comply with all minimum clearances to combustiblesasspecified.

WARNING

Failuretocomplymaycausehousefire.

Page 9: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 9

MT VERNON E2

A C

B D

NOTE: • IllustrationsreflecttypicalinstallationsandareFOR

DESIGNPURPOSESONLY. • Illustrations/diagramsarenotdrawntoscale. • Actualinstallationmayvaryduetoindividualdesign

preference.

D. Alcove

Figure 9.1

*Allminimumslistedaretoacombustiblesurface.

Minimum* MaximumInches Millimeters Inches Millimeters

A Height 43 1092 n/a n/a

B Width 40 1016 n/a n/a

C Depth n/a n/a 36 914

D To Side Wall 6 152 n/a n/a

Page 10: Installation Manual - The Fireplace Showcase

10 7080-131B March 14, 2014

MT VERNON E2

4 Vent InformationA. Venting Termination Minimum Requirements

J or KXV

MI

HAV

G

BV

V

A

B

V

F V

C

B

B

E

LV

D

V

ElectricalService

V

NV N

V

N

N

V

Inside Corner

FIXED CLOSEDOPEN

OPEN

FIXED CLOSED

V X

G

GTermination Cap Air Supply Inlet Gas Meter Restricted Area

O

P

Figure 10.1

A 12 in. AboveFinishGrade(thegradesurfacemustbeanon-combustiblematerial

B 12 in.48in.noOAK

Opendoororwindow:belowortotheside

B 12 in. Opendoororwindow:above

C 6 in. Permanentlyclosedwindow:above,belowor to the side

D 18 in.36in.noOAK

Verticalclearancetoaventilatedsoffitlocatedabovetheterminalwithinahori-zontal distance of 2 ft from the center-line of the terminal

E 12 in. Clearancetounventilatedsoffit

F 12 in. Clearance to outside corner

G 12 in. Clearance to inside corner

H 36 in. Abovegasmeter/regulatormeasuredfromhorizontal center-line of regulator

I 36 in. USA72 in. Canada

Clearancetoserviceregulatorventoutlet

J 12 in.48in.noOAK

Clearance to non-mechanical air supply inlettothebuildingorthecombustionsairinlet to any other appliance

K 10 ft horizontal3ftvertical

Clearance to mechanical air supply

L 7 ft. Abovepavedsidewalk,paveddrivewaylocated on public property

M 12 in. Underanopenveranda,porch,deckorbalcony

N See Note below*

Electricservice:above,belowortotheside(locationmustnotobstructorinterferewithaccess)

O 24 in. Adjacentbuilding,fencesandprotrudingparts of the structure

P 12 in. Clearanceaboverooflineforverticalterminations

All minimum clearances are listed with an Outside Air Kit (OAK) installed, unless otherwise noted in table below.

24 in. Abovegrass,topofplants,woodoranyothercom-bustible

12 in.36in.noOAK

Clearance from any forced air intake of other appli-ance

12 in. Clearancehorizontallyfromcombustiblewall

15 in. Vented directly through a wall, minimum length of horizontal pipe

6 in. horizontal12in.vertical

Minimumhorizontalorverticalterminationsmustprotrude from wall

*NOTE: Consultlocalbuilding,fireofficialsorauthoritieshavingjurisdic-tion.Localcodesorregulationsmayrequiredifferentclearances.

NOTICE:Do NOT Terminate Vent:• Inanylocationthatwillallowfluegasesorsootfromen-

teringorstainingthebuilding• Inanylocationwhichcouldcreateanuisanceorhazard• In any enclosed or semi-enclosed area such as a carport,

garage, attic, crawl space, under a sun deck or porch, narrow walkway

• Closely fencedarea, or any location that canbuild upa concentration of fumes such as a stairwell, coveredbreezeway,etc.

NOTICE:Termination must exhaust above air inlet elevation. • Itisrecommendedthatatleast60inches(1.52m)ofver-

ticalpipebeinstalledwhenapplianceisventeddirectlythrough a wall. This will create a natural draft, which will helppreventthepossibilityofsmokeorodorventingintothe home during a power outage.

• Itwillalsokeepexhaustfromcausinganuisanceorhazardbyexposingpeopleorshrubstohightemperatures.

• Thesafestandpreferredventingmethodistoextendtheventverticallythroughtherooforabovetheroof.

Page 11: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 11

MT VERNON E2

B. Avoiding Smoke and Odors

Negative Pressure, Shut-Down and Electrical Power Failure

To reduce the probability of back-drafting or burn-back inthe pellet appliance during power failure or shut down con-ditions, it must be able to draft naturally without exhaustbloweroperation.Negativepressureinthehousewillresistthisnaturaldraftifnot accounted for in the pellet appliance installation.

Heatrisesinthehouseandleaksoutatupperlevels.Thisairmustbereplacedwithcoldairfromoutdoorswhichflowsintolowerlevelsofthehouse.Ventsandchimneysintobasementsandlowerlevelsofthehousecanbecome the conduit for air supplyand reverseunder these conditions.

Outside Air

Anoutsideairkit(OAK-3)isrecommendedinallinstallationsandmustbeorderedseparately.Pernationalbuildingcodes,considerationmustbegiventocombustionairsupplytoallcombustionappliances.Failuretosupplyadequatecombustionairforallappliancedemandsmayleadtobackdraftingofthoseandotherappliances.

Whentheapplianceisroofvented(stronglyrecommended): Theairintakeisbestlocatedontheexteriorwallorientedtowardstheprevailingwinddirectionduringtheheatingseason.

Whentheapplianceisside-wallvented:Theairintakeisbestlocatedonthesameexteriorwallastheexhaustventoutletandlocatedloweronthewallthantheexhaustventoutlet.

The outside air supply kit can supply most of the demands of thepelletappliance,butconsiderationmustbegiventothetotal house demand. House demand may consume the air needed for the appli-ance. Itmaybenecessarytoaddadditionalventilationtothe space in which the pellet appliance is located. Consult with your local HVAC professional to determine the ventilationdemandsforyourhouse.

VentConfigurationsTo reduceprobability of reversedraftingduring shut-downconditions Hearth & Home Technologies strongly recom-mends:

• Installingthepelletventwithaminimumverticalrunof5feet(1.52m).Preferablyterminatingabovetheroofline.

• Installingtheoutsideairkitatleast4feet(1.22m)belowtheventtermination.

Topreventsootdamagetoexteriorwallsofthehouseandtopreventre-entryofsootorashintothehouse:

• Maintain specified clearances towindows, doors andair inlets, including air conditioners.

• Vents should not be placed below ventilated soffits.Runtheventabovetheroof.

• Avoidventingintoalcovelocations. • Ventsshouldnotterminateunderoverhangs,decksor

ontocoveredporches. • Maintain minimum clearance of 12 inches (305mm)

from the vent termination to the exteriorwall. If youseedepositsdevelopingonthewall,youmayneedtoextend this distance to accommodate your installation conditions.

CAUTION• DONOTCONNECTTHISUNITTOACHIMNEYFLUE

SERVICINGANOTHERAPPLIANCE.

• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.

Page 12: Installation Manual - The Fireplace Showcase

12 7080-131B March 14, 2014

MT VERNON E2

C. Negative Pressure

Negativepressure results from the imbalanceof air avail-ablefortheappliancetooperateproperly.Itcanbestrongestinlowerlevelsofthehouse.

Causesinclude:

• Exhaustfans(kitchen,bath,etc.)• Rangehoods• Combustionairrequirementsforfurnaces,waterheaters

andothercombustionappliances• Clothesdryers• Locationofreturn-airventstofurnaceorairconditioning• ImbalancesoftheHVACairhandlingsystem• Upperlevelairleakssuchas: - Recessed lighting - Attic hatch - Duct leaks

Tominimizetheeffectsofnegativeairpressure:• Installtheoutsideairkitwiththeintakefacingprevailing

winds during the heating season• Ensureadequateoutdoorairforallcombustionappliances

andexhaustequipment• Ensurefurnaceandairconditioningreturnventsarenot

locatedintheimmediatevicinityoftheappliance• Avoid installing theappliancenear doors,walkwaysor

small isolated spaces• Recessedlightingshouldbea“sealedcan”design• Attichatchesweatherstrippedorsealed• Atticmountedductworkandairhandlerjointsandseams

taped or sealed

D. Draft Draftisthepressuredifferenceneededtoventanappli-ance successfully. When an appliance is drafting suc-cessfully,allcombustionbyproductsareexitingthehomethrough the chimney.

Installthroughthewarmairspaceenclosedbythebuild-ingenvelope.Thishelpstoproducemoredraft,especiallyduringlightinganddie-downofthefire.Considerationsforsuccessfuldraftinclude:• Preventingnegativepressure• Locationofapplianceandchimney

WARNINGRisk of Asphyxiation! Negativepressurecancausespillageofcombustionfumes and soot.

NOTICE: Hearth & Home Technologies assumes noresponsibilityfortheimproperperformanceofthechimneysystemcausedby:• Inadequatedraftduetoenvironmentalconditions• Downdrafts• Tightsealingconstructionofthestructure• Mechanicalexhaustingdevices

E. Chimney and Exhaust Connection 1. Chimney & Connector: Use3 or 4 inch (76-102mm)

diametertype“L”or“PL”ventingsystem.Itcanbeventedverticallyorhorizontally.

2. Mobile Home: ApprovedforallListedpelletvent.Ifusingthe3inch(76mm)verticalTopVentAdapterKitorthe3to6inch(76-152mm)TopVentOffsetAdapter,useListeddoublewallflueconnector.AQuadra-FireOutsideAirKit(OAK-3)mustbeusedwithmanufacturedhomeinstalla-tions.

3. Residential: The3inch(76mm)verticalTopVentAdapterKitandthe3to6inch(76-152mm)TopVentOffsetAdapteraretestedtouse24gaugesinglewallflueconnectororListeddoublewallflueconnectortoClassAListedmetalchimneys, or masonry chimneys meeting International Residential Code standards for solid fuel appliances.

4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.

5. Secureexhaustventingsystemtotheappliancewithatleast3screws.Alsosecureallconnectorpipejointswithatleast3screwsthrougheachjoint.

6. DONOTINSTALLAFLUEDAMPERINTHEEXHAUSTVENTINGSYSTEMOFTHISUNIT.

7. DONOTCONNECTTHISUNITTOACHIMNEYFLUESERVINGANOTHERAPPLIANCE.

NOTE: All pipe must be welded seam pipe whenever possible. Seal pipe joints with high temperature silicone (500°F [260°C] minimum rated only).

WARNINGUSEONLYRECOMMENDEDVENTINGCOMPONENTS;OTHERWISEMAKESHIFTPARTSMAYRESULTINPROP-ERTYDAMAGE,PERSONALINJURY,ORDEATH.

Page 13: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 13

MT VERNON E2

F. Equivalent Feet of Pipe

Thetablebelowcanhelpyoucalculatetheequivalentfeetofpipewhichisamethodusedtodeterminepelletventsize.Figure 13.1.

2 ft.

2 ft.

3 ft.

2 ft.

Example of 3 Elbow-Rear Vent Termination Calculation

Pellet Venting Component

# of Elbows

Feet of Pipe

Multiplied By

Equivalent Feet

ComponentsEquivalent Feet

90oElboworTee 3 X 5 1545oElbow X 3Horizontal Pipe 7 X 1 7Vertical Pipe 2 X 0.5 1

TotalEquivalentFeet 23

Note:Thisisagenericexampleandisnotintendedtorepresentanyspecificfueltype.

VentsurfacesgetHOT,cancauseburnsiftouched.Non-combustibleshieldingorguardsmayberequired.

WARNING

Figure 13.2

3 in. or 4 in. (76mm or 102mm) Diameter Pipe

Equivalent Pipe Length In Feet

ALTITUDE IN THOUSANDS OF FEET

0

20

30

1 2 3 4 5 6 7 8 9 10

4 in. (102mm) Diameter Pipe Only

10

Example 1

Example 2

Example 1:Iftheequivalentlengthofpipeis23feet(7m)withaltitudeof8,000feet(2438m)youmustuse4inch(102mm)diametertype“L”or“PL”vent.Example 2:Iftheequivalentlengthofpipeis12feet(3.7m)withaltitudeof6,000feet(1829m)youmayuse3or4inch(76to102mm)diametertype“L”or“PL”vent.

G. Pipe Selection Chart Thechartwill help you indeterminingproper ventingsizeaccordingtotheequivalentfeetofpipecalculatedpreviouslyandthealtitudeabovesealevelofthisinstallation.Figure 13.2

a. Locatethecalculatedequivalentfeetofpipeontheverticalleft side of the chart.

b. Movetotherighthorizontallyonthechartuntilyoureachyouraltitudeabovesealevel.

c. Ifyoufallbelowthediagonalline,3or4inch(76to102mm)pipemaybeused.

d. Ifitisanywhereabovethediagonalline,a4inch(102mm)diameterpipeisrequired.

NOTICE: • A90°elbowis5timesasrestrictivetotheflowofexhaust

gasesunderpositivepressureas1foot(305mm)ofhori-zontal pipe.

• Afootofhorizontalpipeistwiceasrestrictiveasafootofverticalpipe.

WARNINGRISK OF INJURY OR PROPERTY DAMAGE!• Improperinstallation,adjustment,alteration,serviceormain-

tenancecancauseinjuryorpropertydamage.

• Refertotheowner’sinformationmanualprovidedwiththisappliance.

• Forassistanceoradditionalinformationconsultaqualifiedinstaller,serviceagencyoryourdealer.

Risk of Fire! •OnlyLISTEDventingcomponentsmaybeused.

•NOOTHERventcomponentsmaybeused.

•Substituteordamagedventcomponentsmayimpair safe operation.

WARNING

Figure 13.1

Page 14: Installation Manual - The Fireplace Showcase

14 7080-131B March 14, 2014

MT VERNON E2

2 in [51mm] min

6 in[152mm]Min

6 in[152mm]

Min

Non-combustible Hearth Pad

WallThimble

HorizontalTermination

Cap

Straight Out

Figure 14.1

Figure 14.2

Wall Thimble

Illustration shows venting going in both directions. Choose which one is best for your installation.

2 in. (51mm)Minimum

2 in. (51mm) Minimum

6 in. (152mm) Minimum6 in. (152mm)

Minimum

45 Degree

5 Venting Systems

A. Through The WallHorizontalterminationcapmustbeaminimumof6inches.(152mm)fromthewall.Approvedformobilehomeinstalla-tions.Mustuse3or4inch(76-102mm)“L”or“PL”ListedpelletventingorListeddoublewallpipeandaQuadra-FireOutsideAirKitinmobilehomes.

NOTE:In Canada, where passage through a wall or partition ofcombustibleconstructionisdesired,theinstallationshallconformtoCAN/CSA-B365

Page 15: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 15

MT VERNON E2

C. Through The Wall & Vertical - Exterior

Firestop

Flashing

Rain Cap

6 in[152mm]

Min

Non-combustible Hearth Pad

3 in [76mm] Min

Clean-out Cover

12 in. [305mm] Min

Ceiling Support

3 to 6 in [76 to 152mm]Offset Adapter

6 in. [152mm] Class AChimney ConnectorAdapter

3 to 3 in[76-76mm]Top Vent Kit

Non-combustible Hearth Pad

Clean-outCover

Tee

Wall Thimble

SupportBracketevery 60 in[1524mm]

12 in[305 mm]Minimum

RainCap

Flashing

2 in [51mm] min

6 in[152mm]

Min

Figure 15.1

Figure 15.2

D. Vertical - Interior - Typical Installation

Firestop

Non-combustible Hearth Pad

12 in[305 mm]Minimum

RainCap

Flashing

3 in [76mm] Min

6 in[152mm]

Min3 to 3 in[76 to 76mm]Top Vent Kit

Clean-out Cover

Figure 15.3

We recommend a minimum of 60 inches (1524mm) vertical, however above the eaveis preferred. Allthreeinstallationsareapprovedformobilehomeinstallations. Mustuse3or4 inch(76to102mm)“L”or“PL”ListedpelletventingorListeddoublewallpipeandQuadra-FireOutsideAirKit inmobilehomes. Singlewallpipe isapprovedforresidentialinstallationsonly.

*NOTE: Clearance to combustibles are forstandard pellet pipe. If pellet pipe manufacturer allows reduced clearances to their pipe, reduced clearances are allowed.

B. Vertical into Existing Class A Chimney

NOTE:A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a foor or ceiling.

Page 16: Installation Manual - The Fireplace Showcase

16 7080-131B March 14, 2014

MT VERNON E2

E. Masonry

F. Alternate MasonryConcrete Cap

Non-combustible Hearth Pad

6 in[152mm]

Min

Airtight clean-out door

Sheathing

1 in [25mm] clearnance

2 in [51mm] min tocombustible material

Flashing

Fireclay Flue Linerwith airspace

1 in [25mm] clearancewith firestop

Figure 16.1

Figure 16.2

Concrete Cap

Non-combustible Hearth Pad

6 in[152mm]Min

Airtight clean-out door

Sheathing

1 in [25mm] clearnance

Flashing

Fireclay Flue Linerwith airspace

1 in [25mm] clearancewith firestop

3 in [76mm] min tocombustible material

Clean-out cover

Fire Risk.InspectionofChimney:• Masonrychimneymustbeingoodcondition.• MeetsminimumstandardofNFPA211• Factory-builtchimneymustbeaminimum6inch(152mm)

UL103 HT.

WARNING

Page 17: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 17

MT VERNON E2

6 Appliance Set-Up

Figure 17.3 - Bolt fully extended

Figure 17.2

Figure 17.1

A. Leg Leveling System 1. ThreadAllenboltsthroughnutsuntilflush.Figure 17.1.

The Allenboltsandnutsareincludedinthecomponentpackinside the appliancefirebox.

2.Slideassemblednutsandboltsintoslotsonlegswiththenutsonthebottom.Figure 17.2.Usea5/32in.(3.96mm)Allenwrenchtoadjustlegsupanddowntodesiredlevel.Figure 17.3.

B. Outside Air Kit Instructions

Included in Kit:2wireties,1collarassembly,1terminationcapassembly,1trimring,fasteners.

NOTE: 3 INCH ALUMINUM FLEX PIPE NOT INCLUDED.Tools Needed:Phillipsheadscrewdriver;wirecuttersholesaworjigsaw.

1. Measuredistancefromfloortoairventopeninginappli-ance and mark location on wall. Usesaw tocutopening inwall.Cuta3-1/2 to4 inch(89-102mm)openingoninsidewallanda4to4-1/2inch(102-114mm)openingonoutsideofhouse.

2. Usewiretietosecureflexpipetocollarassembly.3. Slidetrimringoverflexpipeandrunpipethroughwall.4. Attachflexpipe(notsupplied)tooutsideterminationcap

with second wire tie.5. Secure termination cap to outside surface.6. Secure trim ring to interior wall.

CAUTIONNeverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• Enclosedspacesuchasanatticorgarage

Figure 17.4 - OAK exploded view

Termination Cap

Wire Tie

Trim Ring

Wire Tie

Collar

3 inch Aluminum Flex Pipe(not included)

Page 18: Installation Manual - The Fireplace Showcase

18 7080-131B March 14, 2014

MT VERNON E2

3 in. to 6 in. Offset Adapter

Silicone Rear Exhaust Outlet

3 in. to 3 in. Top Vent Adapter

Clean-Out Cover

Drill Hole, 1 on each side

C. Top Vent Adapter Installation

3 to 3 inch (76-76mm) Top Vent Adapter 3 to 6 inch (76-152mm) Top Vent Offset Adapter Installing the Top Vent Adapter 1. Put a layer of high temperature silicone on the 3 inch

(76mm)exhaustoutlet. Do not put silicone inside of pipe. Figure 18.1.

2. Slidethetopventadapterontotherearexhaustoutletandadjusttheassemblytoaverticalpositionuntilthetopoftheflueoutletiscenteredandisinalevelposition.Figure 18.1.

3. Alignslotonleftofadapterwithholeinthebackoftheunit and secure with screw. You may drill out the hole using#26drillbitprovidedbutonly ifneeded. Figure 18.2.

4. Install the 5 mounting screws, 3 on the left and 2 on the right.

5. Drill2holeswith#26drillbitthroughtherearexhaustoutlet using the 2 holes already in the short horizontal pipeinthetopventadapterasaguide.Installthescrews.

6. Installtheventpipeintothetopventadapter(besuretosiliconealljoints).Touseanexisting6inch(152mm)vent system, install the 3 to 6 in (76-152mm) offsetadapterbeforeinstallingventpipe.

7. To clean top vent adapter, open clean-out cover andremoveanydebrisbuild-up.Figure 18.2.

Figure 18.2

Figure 18.1

D. Rear Vent & Rear Vent to Top Vent Adapter Installation

Clean-Out Cover

Clean-Out Cover

Figure 18.3 - Rear Vent Adapter

Figure 18.4 - Rear to Top Vent Adapter - 90o

1. Put a layer of high temperature silicone on the 3 inch (76mm)exhaustoutlet. Do not put silicone inside of pipe. Figure 18.1.

2. Slidetheadapterontotherearexhaustoutletandadjusttheassemblytotheappropriateposition.

3. Installtheventpipeintotheadapter(besuretosiliconealljoints)

Page 19: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 19

MT VERNON E2

CAUTIONLogs are FRAGILE. Use extreme care when handling or cleaning logs.

NOTICE: Duetotheabrasivenatureofapelletappliancefire,thelogsarenotcoveredunderwarranty. Anyplacementvariationotherthanshownherecancauseexcessiveheatandshallvoidtheappliancewarranty.

Figure 19.1

Log fits over screws

Left Log

Log has indentations on the bottom to fit over the screw heads.

Log rests in front of screws

Right Log

Figure 19.3

Figure 19.4

E. Optional Log Set Placement Instructions 2 PIECE LOG SET INSTALLATION

1. Place the left log as shown. There are 2 indentations in thebottomof the log tofitover thescrewheads in thefirebox. Figures 19.1 and 19.2.

2. Place the right log in front of the 2 screw heads in the firebox.Figures 19.3 & 19.4.

Figure 19.2

Page 20: Installation Manual - The Fireplace Showcase

20 7080-131B March 14, 2014

MT VERNON E2

F. Remote Thermostat Installation 1. Whenmountingthethermostatonthewall,besureto

followyourremotethermostat’sinstallationinstructionscarefully.

NOTE: The remote thermostat should be mounted on an inside wall and not in direct line with the ap-pliance convection air.

NOTE: If the remote thermostat is located too close to the appliance, you may need to set the tempera-ture setting slightly higher to maintain the desired temperature in your home.

Photo of Thermostat separated from its docking station below:

Shock hazard.• DoNOTremovegroundingprongfromplug.• Plugdirectlyintoproperlygrounded3prong

receptacle.• Routecordawayfromappliance.• DoNOTroutecordunderorinfrontofappliance.

CAUTION

Tools Needed:PhillipsscrewdriverPower Drill

1/4”or7/64”drillbitTape Measure

Detachtheremotethermostatfromitsdockingstationbypulling them directly away from each other.

Usingthefastenersand(ifneeded)anchors–includedwiththeremotetransmitterpackaging–fastenthedockingstation to the wall.

IMPORTANTNOTES:Forbestapplianceperformance,positionthedockingstationat60inchesheightfromthefloor,nofurtherthan20feet from the appliance, out of direct sunlight, and out of the directflowofconvectionaircomingfromtheapplianceorstructure’sHVACdischargeair.

For instructions on thermostat function and interaction with theappliancerefertotheowner’smanual.

G. Power Cord1. Prior to installing the power cord, turn the dial control

“OFF”.2. Makesurethewallreceptaclehas120vacoutput.

NOTE:Usingacircuitprotectorcanprotecttheappli-ance circuits from power surges.

3. Theappliancerecepticalislocatedonitslower,backright hand corner. Install the cord to wall and appliance reception.

4. Refertoowner’smanualforapplianceoperation.

Page 21: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 21

MT VERNON E2

7 Mobile Home Installation

You must use a Quadra-Fire Outside Air Kit for installation in a mobile home.

1. Anoutsideairinletmustbeprovidedforthecombustionairandmustremainclearofleaves,debris,iceand/orsnow.Itmustbeunrestrictedwhiletheapplianceisinusetopreventroomairstarvationwhichcausessmokespillage. Smoke spillage can also set off smoke alarms.

2. Thecombustionairductsystemmustbemadeofmetal.Itmustpermitzeroclearancetocombustibleconstruc-tionandpreventmaterialfromdroppingintotheinletorintotheareabeneaththedwellingandcontainarodentscreen.

3. The appliancemust be secured to themobile homestructurebyboltingittothefloor(usinglagbolts).Usethe same holes that secured the appliance to the shipping pallet.

4. Theappliancemustbegroundedwith#8solidcoppergroundingwireorequivalent, terminatedateachendwithanNECapprovedgroundingdevice.

5. RefertoClearancestoCombustiblesandfloorprotectionrequirementsonpage 8forlistingstocombustiblesandappropriate chimney systems.

6. Usesiliconetocreateaneffectivevaporbarrieratthelocation where the chimney or other component pene-trates to the exterior of the structure.

7. Follow the chimneymanufacturer’s instructionswheninstallingtheventsystemforuseinamobilehome.

8. InstallationshallbeinaccordancewiththeManufacturersHome&SafetyStandard(HUD)CFR3280,Part24.

Part Number: OAK-3

NEVERINSTALLINASLEEPINGROOM.

WARNING

Spark Arrestor Cap

Roof Flashing

Storm Collar

Joist Shield/Firestop Approved Class L or PL Pellet Vent

Figure 21.1

CAUTIONNeverdrawoutsidecombustionairfrom:• Wall,floororceilingcavity• Enclosedspacesuchasanatticorgarage

CAUTIONTHESTRUCTURALINTEGRITYOFTHEMOBILEHOMEFLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINEDDoNOTcutthrough:• Floorjoist,wall,studsorceilingtrusses.• Anysupportingmaterialthatwouldaffectthestructural

integrity.

Thisunitistobeconnectedtoafactory-builtchimneyconformingtoCAN/ULC-S629,Standardfor650°CFactory-Built Chimneys.

Forremovalofthechimneyformobilehometranspor-tation,contactthepropertransportationofficials.

WARNINGProductsofcombustiongeneratecarbonmonoxide

anddifferentfuelsgeneratedifferentlevels.Carbonmonoxide

• Onlyuseapprovedfuelsinthisappliance.• Alwayskeepdoorshutduringoperation.Operating

thisunitwithdoorsopencanallowCOtoleakintothehome.

COcankillyoubeforeyouareawareitisinyourhome.Atlowerlevelsofexposure,COcausesmildeffectsthatareoftenmistakenfortheflu.Thesesymptomsincludeheadaches, dizziness, disorientation, nausea and fatigue. TheeffectsofCOexposurecanvarygreatlyfrompersontopersondependingonage,overallhealthandtheconcentration and length of exposure.

WARNING It is critical to have a working smoke detector

installed in the home of unit operation.

• Smoke alarms that are properly installed and maintained playavitalroleinreducingfiredeathsandinjuries.Havingaworkingsmokealarmreducesthechanceoffirerelatedinjuries..

Page 22: Installation Manual - The Fireplace Showcase

22 7080-131B March 14, 2014

MT VERNON E2

8 Accessory List

Service PartsR

MT VERNON E2Beginning Manufacturing Date: Dec 2013

Ending Manufacturing Date: Active

IMPORTANT:THISISDATEDINFORMATION.Partsmustbeorderedfromadealerordistributor.Hearth and Home Technologies does not sell directly to consumers.Providemodelnumberandserialnumberwhenrequestingservicepartsfromyourdealerordistributor.

Stockedat Depot

ITEM DESCRIPTION COMMENTS PART NUMBER

ComponentPackAssembly(IncludesOwnersManual,QuickStart Guide, Heat Exchange & Exhaust Cleaning Instructions, WarrantyCard,Dvd“HowTo”,WallControl&Harness,PowerCord,(4)LevelingNuts&Bolts,FirepotClean-OutTool,Touch-UpPaintandLabel

Matte Black SRV7080-040

Porcelian Black SRV7080-043

Porcelian Dark Blue SRV7080-044

Porcelian Frost SRV7080-045

Porcelian Mahogany SRV7080-042

Sienna Bronze SRV7080-041

Cleanout Tool 414-1140 YLevelingAssembly 7000-000

Paint Touch-Up

Matte Black 812-0910Porcelian Black 1-00-0022

Porcelian Dark Blue 1-00-0020Porcelian Frost 1-00-0021

Porcelian Mahogany 855-1450SiennaBronze TOUCHUP-CSB

Power Cord 812-1180 YHeatingElementAssembly18”,120VAC,300Watt,(Wood Pellet Fuel Only)

SRV7000-647 YPkgof10 SRV7000-647/10 Y

WingThumbScrew8-32X1/2 Pkgof24 7000-223/24 YWireClip Pkgof10 7000-400/10 Y

ACCESSORIES

Collar,Offset,TopVent 812-3570Damper,3Inch-TallVerticalInstallsOnly PEL-DAMP3 YDamper,4Inch-TallVerticalInstallsOnly PEL-DAMP4Firescreen SCR-7005LogSet,(SoldasSetonly) 2Pc LOGS-60-AE-BOutsideAirKit OAK-3Top Vent Adapter TPVNT-3Vent Adapter, 3-4” 811-0720Vent Adapter, 90, Cleanout TPVNT-6Vent Adapter, Rear 811-0620

WarmingShelves

Matte Black 844-9780Porcelian Black WSLG-PBK

Porcelian Dark Blue WSLG-PDBPorcelian Frost WSLG-PFT

Porcelian Mahogany 844-9810Sienna Bronze WSLG-CSB

Page 23: Installation Manual - The Fireplace Showcase

March 14, 2014 7080-131B 23

MT VERNON E2

Page 24: Installation Manual - The Fireplace Showcase

24 7080-131B March 14, 2014

DO NOT DISCARD THIS MANUALCAUTION

• Importantoperatingandmaintenance instruc-tionsincluded.

• Leave thismanualwithpartyresponsibleforuseandoperation.

• Read,understandandfollow these instruc-tionsforsafeinstalla-tionandoperation.

DO NOTDISCARD

CONTACT INFORMATION

Hearth&HomeTechnologies1445NorthHighwayColville,WA99114

DivisionofHNIINDUSTRIES

Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer

log onto www.quadrafire.com

Thisproductmaybecoveredbyoneormoreofthefollowingpatents:(UnitedStates)5341794,5263471,6688302,7216645,7047962orotherU.S.andforeignpatentspending.

We recommend that you record the following pertinent information for your heating appliance.

Datepurchased/installed:

SerialNumber: Locationonappliance:

Dealershippurchasedfrom: Dealerphone:

Notes: