1.0 General and Safety• Donotinstall,operateormaintainthisflowmeterwithoutreading,understandingandfollowingthefactory-suppliedinstructions.Otherwise,injuryordamagemayresult.
• Readtheseinstructionscarefullybeforebeginninginstallationandsavethemforfuturereference.• Observeallwarningsandinstructionsmarkedontheproduct.• Considerhandlingandliftinginstructionstoavoiddamage.• Iftheproductdoesnotoperatenormally,refertotheserviceinstructionsortoaqualifiedARADserviceengineer.• Therearenooperator-serviceablepartsinsidethisproduct.
2.0 Product Liability and Warranty
Arad’sstandardproducts(the“Products”)aresoldtoCustomerandarepurchasedbyCustomerunderthetermsofwarrantysetforthhereinbelow:
1.AradwarrantsthattheProductsshall,underconditionsofnormaluseandwhenproperlyinstalled,administered,appliedandmaintained,befreefromdefectsinmaterialandworkmanship(the“Warranty”),foraperiodof12monthsfollowingdeliverythereoftoCustomer(the“Warranty Period”).
2.Arad’ssoleobligationandliabilityundertheWarrantyshallbelimitedtothereplacement,therepairortherefundoftheoriginalpurchaseprice,atArad’ssolediscretion,ofanydefectiveProductswhichareprovennottoconformtotheProducts’specificationandwhicharereturnedtothefactoryorservicecenterdesignatedbyAradduringtheWarrantyPeriodbytheCustomeraftercompletingafailurereport.AllprovidedthatwrittennoticeofsuchdefectisgivenbytheCustomertoAradwithin21daysafterdiscoverythereof.FreightcosttosuchfactoryorservicecenterwillbepaidbytheCustomerandfreightcostfromsuchfactoryorservicecentertoCustomerwillbepaidbyArad.
3.AradwillnotberesponsibleforandwillhavenoobligationundertheWarrantytoanynon-conformityoftheProducts,caused,inwholeorinpart,asaresultofmisuse,abuse,tamperingwithormodificationofanyoftheProductsand/orbyaccidents,faultornegligence,improperadministration,applicationand/oruse,installation,service,repairand/ormaintenanceoftherelevantProducts,byactofvandalismorbyanycauseswhatsoever(includingbutnotlimitedtoenvironmentalconditions)thatareexternalthereto.
4.Theforegoingwarrantyisalimitedwarrantyandisexclusiveandinlieuofallotherwarranties,expressorimplied,including,butnotlimitedto,theimpliedwarrantiesofmerchantabilityandfitnessforaparticularpurposeandshallconstitutetheCustomer’ssoleandexclusiveremedywithrespectthereto.ReplacementorrepairinthemannerprovidedabovewillconstitutefulfillmentofallofArad’sobligationswithrespecttothequalityandperformanceoftheproducts.Nodealer,distributor,agentoremployeeofeitherAradorcustomerisauthorizedtomodifythesewarranties.SuchmodificationshallbenullandvoidandshallnotbindAradforanyandallpurposes.
5.Exceptandtotheextentprovidedunderthewarranty,innoeventshallAradbeliable,whetherincontract,tortorotherwise,foranydamages,whetherdirectorindirect,consequential,incidental,specialorpunitive,resultingfromanydefectintheproducts,including,withoutlimitation,lossofprofits,business,income,anticipatedsavings,goodwillorothercommercialloss,evenifAradhadbeenadvisedofthepossibilityofsuchdamages,excepttotheextentthatsuchliabilitymaynotlawfullybeexcluded.
Customershallbesolelyresponsiblefortheselection,use,efficiencyandsuitabilityoftheProducts.
3.0 Items Included With Order:• OneOCTAVEultrasonicflowmeter,sizeasindicatedonthepackagingbox,piecedtogetherintoacompletecompactsystem(flowtubepluselectronics).
• OneOUTPUTmodule,eitherdigitaloranalog(basedonthecustomer’sorder).
3
4.0 Supplied Documentation:• Condensedinstallationandusermanual.• Reportoffactorymetersettings.• Certificateofcalibrationdata.
5.0 Unpacking and Inspection• Thisproducthasbeenthoroughlyinspectedandtestedbeforeshipmentandisreadyforoperation.• Aftercarefullyunpackingthemeter,inspectforshippingdamagebeforeattemptingtoinstall.Ifanyindicationofmechanicaldamageisfound,immediatelycontacttheresponsibletransportationserviceandyourlocalARADLTD.representative.
6.0 System Description and Measurement Method • TheOCTAVE’smeasurementmethodisbasedonanultrasonic,transit-time,dual-beamsensorswhichdeterminesthelengthoftimeittakesanultrasonicsoundwavetotravelthedistancebetweenthetwosensorslocatedonthemeter’sbody.Thesensorsfunctionasboththesenderandthereceiver,eachonealternatingthesefunctionssothattheultrasonicwavetravelsbothwithandagainstthedirectionoftheflow.Sincetheultrasonicwavetravelssloweragainsttheflowthanwiththeflow,thetimedifferenceoftwowavestravelingwithandagainsttheflowleadstodeterminingthevelocityofthewater.
• TheOCTAVEultrasonicflowmeterisabattery-poweredprecisionflowmeterdesignedforlinear,bidirectionalflowmeasurementofwater.
• Flowmeasurementvaluescanbetransferredthroughthestandardcomminucation-digitaloranalogoutput.• TheOCTAVEcanbesetupforawiderangeofapplications.
7.0 Mechanical DataMaximum Working Pressure 16 bar
Liquid Temperature 0.1 up to 50 º C
Precision Class ISO 4064 rev.2005, Accuracy class 2
Configuration Compact - The display is built in to the unit
Power Source 2 D size Li-battery: 10 years life time
Environmental Protection IP 68, Ambient operation temp. -25°C up to +55°C
Display Units Multi line 9 digit LCD display (Flow rate and volume units are programmable)
Volume Display Options1. Net (Forward less reverse)2. Forward only3. Forward & reverse alternating
Outputs (optional)
4-20mA (powered loop)Dual digital pulses process (open collector)Dry Contact Encoder output
Coupling Threads (only 11/2” and 2”) BSP (See also instructions for installation of Octave with polymer body)
Connections Flanges according to ISO, BS 10 and ANSI 150
Severity levels Mechanical class M1 Electromagnetic environment class E1
Pressure Loss ΔP 16
4
8.0 Mechanical Installation8.1 Handling the Flow Meter
Importanthandlinginformation:• DonotlifttheOctavebytheelectronichousing.• DonotcarrytheOctavebyitslid.• DonotplacetheOctaveontheelectronichousing.• WhenhandlingtheOctave,avoidhardblows,joltsorimpacts.
8.2 Installation: Location and PositionRecommended installation Conditional installation Wrong installation
Recommended:Ifthisisnotthehighestpointinthesystemorahydraulicjumphasbeeninstalledtokeeptheflowmeterfull.
Not recommended:Ifthisisthehighestpointinasystemorifpipelineand/orflowmeterissubjecttobeingemptiedbetweenusesavoidthisinstallation.
Dimensions
H
L B
h
Model Octave
Nominal size (mm) 40 Threaded 50 Threaded 50 65 80 100 150 200 250 300
(inch) 1½ Threaded 2 Threaded 2 2.5 3 4 6 8 10 12
L – Length without couplings(mm) 300 300 200 200 225 250 300 350 449 499
W – Width(mm) 113 113 165 185 200 220 285 340 406 489
H – Height(mm) 155 155 194 210 210 223 282 332 383 456
h – Height(mm) 35 35 40 90 90 103 140 165 203 245
Weight (kg) - cast iron body 8 9 11.5 13 15 32 45 68 96
Weight(kg) -polymerbody 1.4 1.45
FlowDire
ction
FlowDirection
FlowDire
ction
FlowDirection
5
2 DN
2 DN
2DN
2DN FlowDirection
2DN
10DN
FlowDir
ection
2DN
FlowDire
ction
2DN
FlowDir
ection
2DN
2DN
FlowDir
ection
The Following Examples are Arad’s Recommendations For Achieving Top Performance
Minimumoften(10)pipediametersafterpumps
Minimumoftwo(2)pipediametersafterstrainers
Minimumoftwo(2)pipediametersbeforeTconnections
2pipediametersbeforeandafterelbows(90°)inverticalinstallations
2pipediametersbeforeandafterelbows(90°)
Minimumoftwo(2)pipediametersbeforeandafter
• WheninstallingtheOctavedownstreamofanyhydrauliccomponent(valve,pump)therecommendedinstallationrequirementsarenolessthanthedrawingsrecommendations.
Forupstream&downstreamstraightpipespleaseuseasmuchasinstallationsitewillallow(thelongerthebetter)
• WheninstallingPressureBreakerafterthemeter-thepipelengthshouldbeatleast2pipediameter(thelongerthebetter).
FlowDir
ection
6
1. ItisrecommendedthatthemeterwillNOTbeinstalledinthemiddleofthesystem,sothemeterwillnotsufferfromtheloadofalltheinstalledfixtures.
9.0 Polymeric Octave Installation – General InstructionsPleasefollowthegeneralinstructionsforwatermeters(CheckValve,upstream&downstreamandsystemflushingonnewinstallations).
Existingandnewinstallations:
2.ItisrecommendedthatatleastonesideofmeterwillbeconnectedtoaPVC(orplastic)pipe.
1mmmax
Rubbergasket
4.Whenusingstandardtailpiece,pleaseuserubbergasketsonly(notfiberglass)!Afteraddingthegasketsthegapbetweentheendconnectionandthemetershouldnotexceed1mm.Pleaseunscrewtheendconnectioninordertokeeptherecommendeddistance.
• Please do not use force in order to close the gap.• Pleasedon’tdoanyweldingwhilethemeterisconnectedtothepipe.
3.Pleasemakesurethattheendconnectionsareparallelandinlinetoeachother.
7
PlasticendconnectionSupport
5.Ifitisnotpossibletouseplasticconnectionsononesideofthemeter,pleaseconsidertheuseofour flexible couplings.ThesecouplingswereespeciallydevelopedforthepolymericOctavemeters.Youwillneedtousethiscouplingonlyononesideofthemeter-pleaseinstallthecouplingontheoutlet,ifpossible-asdescribedinthebelowpictures.
6.Pleasestarttotightentheendconnectionsbyhand.Finaltighteningwillbewithnomorethan100Nmtorque.
7.Pleasedon’tdoanyweldingwhilethemeterisconnectedtothepipe.
5mmMAX
3mmMAX
8.Incaseitisnotpossibletouseplasticendconnections(atleastononeside),pleasesupportthemeterasshowninthedrawingbelow.
8
• Forproperflowmeasurements,theOCTAVE’smeasuringtubeshouldbecompletelyfullatalltimes.Non-wettedsensorsshowlossofsignal.Thoughthiswillnotcausedamagetothemeter,itwill,however,notmeasureflowanddisplayzero.
• Flowdirection:TheOCTAVEisabidirectionalflowmeter.NotetheindicatingarrowontheOCTAVE’sdisplayforforwardandbackwardflows.
• Incaseofdirectsunlightexposure,itisrecommendedtokeepthelidclosed,thoughnodirectdamagewilloccurwiththelidopen.
• DonotexposetheOCTAVEtoexcessivevibration.Toavoidvibration,supportthepipelineonbothsideofthemeter
• Ambientworkingtemperature:-25to+55°C.
• Waterworkingtemperature:0.1to+50°C.
• Toavoidmeasuringerrorsduetoairintheflowtube,observethefollowingprecautions:• Sinceaircollectsatthehighestpointofthesystem,installationoftheflowmetershouldbeatthelowestpoint.• Alwaysinstallcontrolvalvesdownstreamofthemeterinordertoavoidcavitation.• everinstallthemeteronapumpsuctionsideinordertoavoidcavitation.
11.0 Counter Flanges• Refertothestandarddimensionaldrawingsforflangespacing,accommodatingforthethicknessofgaskets.• Installmeterinlinewiththepipeaxis.Theflangefacesmustbeparalleltoeachother.• Permissiblelengthdeviation:Lmax-Lmin0.5mm(0.02”).
12.0 Start-upD Checkthatthemeterhasbeeninstalledcorrectly.D Checkthattheflowrateandvolumeunitsarecorrectlypreprogrammedonthedisplay.D Checkthattheoutputmoduleiscorrectlyattached.
10.0 Notes
13.0 Digital Display
Volumeunitsm3
Flowrateunitsm3/h
Batterylevel
Flowdirection
OutputMode
Alarm/NoWater/Error
9
1
100ohm
100ohm
1
1
1
1
ShortCable
LongCable
Octave Pulse
Read-outinstrument
EMI / RFI /OverVoltagePROTECTION
Ground Cable
RED
GREEN
BLACK
SHIELD
Pulse#1
Pulse#2
GND
GROUND
14.0 Electrical OutputsTheOCTAVEhasseveraloutputsoptions.1.Dualpulseoutputforvolumes.2.DryContactoutputforvolume.3.Analogoutput(4-20mA)forflow.
14.1.1 Pulse Output Module SpecificationPulsetypes: 1.Opencollectorthatallowscurrentloadingof200mA,andupto50volt. 2.Drycontact.
CablesWarning - Signal connection polarity is mandatory!
Wire Function
Longcable
Red PulseOut#1
Green PulseOut#2
Black GND
Open Ground/Shield
Shortcable RingTerminal Ground
Output Characteristics
Outputs Type Open DrainCableLength-supplied 1.5/5[meter]
MaximumCableLength* 500[meter]
MaximumAppliedVoltage 30[Vdc]
*ThemaximumCablelengthdependson:Cabletype,controlerandelectricalnoiselevelCableTeldoorPN8005003101orsimilar
Outputs Diagram
10
14.1.2 Dry Contact Module SpecificationOutputs Diagram
Cables
Wire Function
LongcableRed+Orange Out#1
Black+Brown Out#2
Shortcable*
Red 24V+
Black 24V-
Yellow GROUND
* Signal connection polarity is mandatory!
Output Characteristics
Outputs Type Dry ContactCableLength-supplied 1.5/5[meter]
MaximumCableLength* 500[meter]
SupplyVoltage 24[Vdc]
*cableTeldoorPN8005003101orsimilar
ShortCable
LongCable
Out#1
Out#2
24Vdc
GROUND
Read-outinstrument
OctaveDry Contact
v1.0
11
1 4 . 1 . 3 4-20mA Module (Analog)• Thecurrentoutputisapassive4-20mA.• 4mAisalways“0”(zero)flowandthe20mAisfactoryprogrammableaccordingtothecustomerrequirements..(Ifthecustomerdidnotspecify,the20mAwillbethemaximumflowrate).
Outputs Diagram
CablesSignal connection polarity is mandatory!
Wire Function
Longcable
Red currentloop+
Black currentloop-
Open GROUND/SHIELD
Shortcable RingTerminal GROUND
Output Characteristics
Outputs Type4-20mA
current outputSuppliedCableLength 1.5/5[meter]
MaximumCableLength* 500[meter]
Loopsupplyvoltage 12-24[Vdc]
OutputImpedance 25[M]typ
*cableTeldoorPN8005003101orsimilar
ShortCable
LongCable
GROUND
Octave4/20mAmodule
Shield
GROUND
Read-out+ -
instrument
(+)
(-)
12
15.0 Module Replacement / Mounting Manual1.Properlydrytheareaoftheconnector.
2.Removesealcoverfromthescrewusingtoolwithsharpedge.3.RemovethescrewsusingAllenkey3mm.4.Removethemodule/cover.5.Properlydryagaintheareaoftheconnector.6.Makesurethemoduleo-ringisinposition.Ifnot,Insertnewo-ringintothemodule.Theo-ringmustbelubricated(siliconegrease).
7.Attachmoduletotheconnector.
8.Tightbothscrewsbyhandonly,usingAllenkey3mmtoachievesymmetrico-ringpressure,then apply the torque 2 N*m with torque wrench.
9.Insertsealcoverontothescrew.
13
16.0 GND Mounting Manual1. InsertM5screwtoringterminallug
2. Insertflatwasherontopofringterminallug
3. Insertserratedwasheronflatwasher
4. Attachtotheforkterminallugandtight
5. Insertflatwasherandserratedwasheronthebolt.Usethecorrectwashersaccordingtoboltsize(M16orM20respectively)Insertthebolttotheholeonthepipe’sflange.(Donotinstallonmeter’sflange)
14
6. Slidetheforkterminallugbetweentheflatwasherandserratedwasher
7. Addserratedwasherontheothersideofthebolt(Onmeter’sflangeside)
8. Addflatwasherontheserratedwasher
9. Addnutandtight.Makesureforkterminallugisinposition.
15
16.1 Special PartsSetforringterminallug
Setforconnectingforkterminallugtopipe
Forkterminallug
M16orM20bolt.Notincludedinkit
FlatwasherM16&M20(2unitseachsize)Includedinkit
SerratedwasherM16&M20(2unitseachsize).Includedinkit
M16orM20nutNotincludedinkit
Serratedwasher
Flatwasher M5screw
Ma
rch
20
15
Innovation through precision,quality and performance
AradLtd.1923900Dalia,ISRAELTel:(972)4-9897911Fax:(972)4-9897965www. a r a d . c o . i l