Installation Ipasolink 1000

download Installation Ipasolink 1000

of 206

description

hi

Transcript of Installation Ipasolink 1000

  • i iPASOLINK 1000CHAPTER I INSTALLATION

    CONTENTS1. OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1

    2. COMPOSITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1

    2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12.1.1 IDU and ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22.1.2 Pole Mounting Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32.1.3 iPASOLINK 1000 Composition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32.1.4 IDU and ODU for 1+0 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-42.1.5 IDU and ODU for 1+1 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5

    2.2 iPASOLINK 1000 IDU Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62.2.1 Cards for Universal Slots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6

    2.2.1.1MODEM-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62.2.1.2STM-1A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62.2.1.316E1-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-62.2.1.4GbE-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72.2.1.5AUX-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72.2.1.6MSE-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-72.2.1.7CWDMFA/CWDMFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7

    2.2.2 Fundamental Cards for iPASOLINK 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . 2-82.2.2.1MC-M (Main Card). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-82.2.2.2PS-M (Power Supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-82.2.2.3TERM-M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8

    2.2.3 CWDM Filter Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-92.2.3.1CWDMFA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-92.2.3.2CWDMFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9iPASOLINK 1000: INSTALLATION NWD-118789-04EDecember, 2011

    3. UNPACKING IDU and ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1

    4. MOUNTING IDU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

    4.1 Mount IDU / CWDM Filter Box Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1

    4.2 Replace FAN Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3

    4.3 Replace MODEM-A/(*)-A Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5

    4.4 Replace MC-M Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-8

    4.5 Replace CLK2M-C Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-11

  • ii CONTENTS4.6 Replace PS-M Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-15

    4.7 Replace PS-M Fuse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18

    4.8 Replace TERM-M Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-19

    4.9 CWDM Filter Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-224.9.1IDU and Filter Box Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-224.9.2Mount CWDMF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23

    4.10 Mount SFP Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-244.10.1SFP Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-244.10.2Colored SFP Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25

    5. MOUNTING ODU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1

    5.1 Antenna Direct Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35.1.1 Basic Installation for Antenna & ODU . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-35.1.2 With Hybrid/Coupler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-185.1.3 With TX Span Attenuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-365.1.4 With Ortho-Mode Transducer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-39

    5.2 Feeder Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-455.2.1 For Coaxial Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-455.2.2 For Waveguide Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-495.2.3 For Waveguide Connection with Hybrid . . . . . . . . . . . . . . . . . . . . . . . . . 5-54

    5.3 Other Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-605.3.1 Wall Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-605.3.2 Rack Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-64

    5.4 Hybrid Combiner Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-66

    6. ADJUSTING CABLE ENDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1

    6.1 5D Coaxial Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3

    6.2 8D Coaxial Cable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-32

    6.3 Other Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-44

    7. WIRING and FORMING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

    7.1 Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1

    7.2 Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27.2.1 Connector Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-27.2.2 Connect I/F Cable with L-angle Plug to IDU . . . . . . . . . . . . . . . . . . . . . . . . 7-4

    7.3 Rout Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-67.3.1 Grounding Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6NWD-118789-04E iPASOLINK 1000: INSTALLATION

    7.3.2 IF Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-6

  • CONTENTS iii 7.3.3 Power Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-77.3.4 16E1, STM-1, GbE and AUX Signal Cables . . . . . . . . . . . . . . . . . . . . . . . . . 7-87.3.5 XIF Coaxial Cables (XPIC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

    7.3.5.1Connection for XPIC 1+0. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-97.3.5.2Connection for XPIC 1+1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-10

    7.3.6 Cables Using CWDM Filter Boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-117.3.6.1Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-117.3.6.2For CWDMF on IDU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-127.3.6.3For CWDM on Filter Box Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-12

    7.4 Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-137.4.1 MC-M Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-137.4.2 TERM-M Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-147.4.3 PS-M Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-157.4.4 AUX-A Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-167.4.5 16E1-A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-17

    8. GROUNDING THE FRAME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1

    9. WATERPROOFING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-1

    10. START-UP and SHUT-DOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1

    10.1 Start-up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-1

    10.2 Shut-down . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3

    10.3 System #2 #4 ODU Expansion. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3

    11. ORIENTING ANTENNA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-1iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • iv /END CONTENTSThis page is intentionally left blank.NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • OVERVIEW 1-11. OVERVIEW

    The standard installation is summarized in this section. Following shows the typical installation work flow and guides to IDU installation, ODU installation, Antenna (ANT) installation, waveguide connection and coaxial cable connections. The installation flow chart is shown below.

    This product is a part of the radio link system, and is intended to be connected with a external antenna.

    This product should be installed and operated by skilled personnel.

    After the installation, the system should be ensured to comply with the relevant limits for general public exposure specified as basic restrictions or reference levels in the council Recommendation 1999/519/EC.

    Unpacking IDU(see Section 3.)

    Unpacking ODU(see Section 3.)

    Mounting ODU(see Section 5.)

    Mounting IDU(see Section 4.)

    Groundingthe Frame

    (see Section 8.)

    Terminating Cables(see Section 6.)

    Waterproofing (see Section 9.)

    Wiring and Forming(see Section 7.)

    Orienting Antenna(see Section 11.)iPASOLINK 1000: INSTALLATION NWD-118789-04E

    Figure 1-1 Typical Installation Flow Diagram

  • 1-2/END OVERVIEWThis page is intentionally left blank.NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • COMPOSITIONS 2-12. COMPOSITIONS

    2.1 OverviewEach unpacked component of the [ ] GHz [ ] MB digital radio system must be checked as shown below:

    Contents List Subsection

    IDU and ODU 2.1.1 IDU and ODU

    Mounting Bracket 2.1.2 Pole Mounting Bracket

    iPASOLINK 1000 Composition 2.1.3 iPASOLINK 1000 Composition

    Installation Kit 2.1.4 IDU and ODU for 1+0 System2.1.5 IDU and ODU for 1+1 System2.2.1 Cards for Universal Slots2.2.2 Fundamental Cards for iPASOLINK 10002.2.3 CWDM Filter BoxiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 2-2 COMPOSITIONS2.1.1 IDU and ODU

    Note*: Two spare fuses are provided in the IDU packing box.

    Figure 2-1 Contents of Cards

    No. Description

    1 TRP-( )G-1D (ODU)

    2 MDP-400MB-1BB (IDU)

    3 O-Ring (Attached to the waveguide type ODU)

    4 Power Connector [Housing (AMP: 1-178288-8 (x1 ea)) or DK-3100S-10R (x1 ea) and Socket Contacts (AMP: 1-175218-2 (x10 ea))]

    5 Cylindrical Fuse (ES1-12500 (250 V/12.5 AH))*

    31

    5

    4

    (13-42 GHz)(6-11 GHz)

    2NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • COMPOSITIONS 2-32.1.2 Pole Mounting Bracket

    Figure 2-2 Pole Mounting Bracket

    2.1.3 iPASOLINK 1000 Composition

    Figure 2-3 iPASOLINK 1000 Composition

    No. Description

    1 Pole Mounting Bracket for Coaxial Cable (6/7/8 GHz)/Waveguide Connection Type

    2 Pole Mounting Bracket for Antenna direct Mounting Type

    (Supplied with Antenna)

    2

    1

    Universal Slot #1 Universal Slot #2 Universal Slot #3 Universal Slot #4

    Universal Slot #5 Universal Slot #6 Universal Slot #7 Universal Slot #8

    Universal Slot #9

    Universal Slot #10

    MAIN CARD 1

    TERM PS 1

    FAN1

    FAN2

    Main Card Slot #2

    Universal Slot #11 Universal Slot #12 Universal Slot #13 Universal Slot #14

    PS Slot #2

    Slot #

    Slots for fundamental cards that must be mounted.

    Slots for option cards, which can be left vacant.

    PS Power Supply

    Main Card Slot #1iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 2-4 COMPOSITIONS2.1.4 IDU and ODU for 1+0 System

    Figure 2-4 IDU and ODU to be Installed for 1+0 System

    ODU (13-42 GHz)N-P connector N-P connector

    ODU (6-11 GHz)Earth Screw

    (FG)

    TNCP Connector

    Earth Screw (FG)

    Earth Screw(FG)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • COMPOSITIONS 2-52.1.5 IDU and ODU for 1+1 System

    Figure 2-5 IDU and ODU to be Installed for 1+1 System

    ODU (6-11 GHz)ODU (6-11 GHz)N-P connector

    TNCP connector

    N-P connector

    ODU (13-42 GHz)

    N-P connector

    TNCP connector

    N-P connector

    Earth Screw Earth Screw

    ODU (13-42 GHz)Earth Screw Earth Screw Earth Screw Earth Screw

    (FG)

    (FG) (FG) (FG) (FG)

    (FG)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 2-6 COMPOSITIONS2.2 iPASOLINK 1000 IDU Components

    2.2.1 Cards for Universal Slots

    2.2.1.1 MODEM-A

    2.2.1.2 STM-1A

    2.2.1.3 16E1-A

    TNC Connector

    Earth Screw XIF Connectors MD/ODU PWR Switch

    SFP Module Ports CLASS 1 LASER PRODUCT

    MDR ConnectorNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • COMPOSITIONS 2-72.2.1.4 GbE-A

    2.2.1.5 AUX-A

    2.2.1.6 MSE-A

    2.2.1.7 CWDMFA/CWDMFB

    See 2.2.3 CWDM Filter Box.

    RJ45 Modular PortsCLASS 1 LASER PRODUCT

    SFP Module Ports

    Hi-Density D-Sub (44) ConnectoriPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 2-8 COMPOSITIONS2.2.2 Fundamental Cards for iPASOLINK 1000

    2.2.2.1 MC-M (Main Card)

    2.2.2.2 PS-M (Power Supply)

    2.2.2.3 TERM-M

    Protection Switch

    OW Outlet

    CALL Push Button

    USB Port R45 Modular Ports

    SFP Module Ports

    High-Density D-Sub 44-pin Connector

    CLASS 1 LASER PRODUCT

    Power Supply Connector

    R45 Modular Ports

    High-Density D-Sub 15-pin ConnectorNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • COMPOSITIONS 2-92.2.3 CWDM Filter Box

    NOTE: CWDM Fitter Box (CWDMF) is not a managed object within IDU. Thus, retrieving the information of status, inventory, etc., regarding the CWDMF is not available. However, the inventory information for the Colored SFP only can be retrieved.

    2.2.3.1 CWDMFA

    2.2.3.2 CWDMFB

    SFP Module Ports LC Connector PortCLASS 1 LASER PRODUCT CLASS 1M LASER PRODUCT

    SFP Module Ports LC Connector PortCLASS 1M LASER PRODUCTCLASS 1 LASER PRODUCTiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 2-10/END COMPOSITIONSThis page is intentionally left blank.NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • UNPACKING IDU and ODU 3-13. UNPACKING IDU and ODU

    Procedures for unpacking IDU and ODU are shown in following chart.

    IDU: Procedure 3-1

    ODU: Procedure 3-2

    Note When conveying the IDU or ODU to another place, the original packing should be used to avoid damage.

    Procedure 3-1 Method of Unpacking IDU

    1 Open the container box.

    Shipping Tag / Packing Slip(with bar-code)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 3-2 UNPACKING IDU and ODU2 Unbox the contents. The contents are boxed as shown below:

    3 Remove the polyethylene sheet from IDU.

    Top Pad

    (Accessories are taped on the top pad.)

    SFPSFP

    FUSEFUSE

    (Desiccant)

    IDU

    Polyethylene Sheet

    Bottom Pad

    Container BoxNWD-118789-04E iPASOLINK 1000: INSTALLATION

    4 Inspect IDU.

  • UNPACKING IDU and ODU 3-3Procedure 3-2 Method of Unpacking ODU

    1 Remove the top cover of the packing box.

    Recycle Mark

    Package Label

    Package Label

    or

    Recycle Mark

    Care Label

    Care LabeliPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 3-4/END UNPACKING IDU and ODU2 Unbox ODU, cushioning materials (pads) and polyethylene sheet:

    3 Remove the polyethylene sheet from ODU.

    4 Inspect ODU.

    Top Pad

    Polyethylene Sheet

    Bottom Pad

    Container BoxNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-14. MOUNTING IDU

    4.1 Mount IDU / CWDM Filter Box MountNOTE: Procedure below uses IDU for example.

    Procedure 4-1 Methods of Mounting IDU

    1 Supporting brackets are attached on the front of IDU.

    2 Mount IDU onto the 19-inch Rack. Example below uses EIA 310-D [IEC-60297] Rack:

    Attach and half-tighten two screws (with spring and flat washers) for the bottom side (or for the upper side if the rack is IEC-60917) of the shelf.

    Hook the bottom-side (or upper-side if the rack is IEC-60917) keyholes of the flanges onto these screws (). Secure all four screws (with spring and flat washers) including half-tightened screws ().

    Front SideRear View

    ScrewSpring Washer

    Flat Washer

    Keyhole

    Screw HoleiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-2 MOUNTING IDU3 Since the forced-air cooling fans are built in, IDU does not require spaces for the heat dissipation on its top, bottom and rear when installing onto a 19-inch Rack. However, to install cables, the space of about 1U [1.75 inches; 44.45 mm] each above and below the IDU is required.

    IDU

    1U

    1U

    (wall)

    1U = 1.75 inches / 44.45 mm

    1U

    (side view)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-34.2 Replace FAN UnitNotes

    1. NEC recommends that FAN unit be replaced approximately every three years, regardless of its condition.

    2. If a FAN alarm occurs, replace the FAN unit immediately.

    3. The FAN unit is hot-swappable, which allows the replacement without shutting down the system.

    4. When replacing a FAN, a new FAN unit to be mounted should be prepared near.

    Procedure 4-2 Replace FAN Unit

    1 Dismount the defective FAN

    Proceed with the illustrated steps in reverse:

    Step 2: Using the screwdriver, loosen the screw.

    Step 1: Holding the screw, pull the unit out.

    2 Mount a new FAN

    Proceed with the illustrated steps in a regular order:

    Step 1: Insert the new FAN unit.

    Step 2: Using the screwdriver, tighten the screw.iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-4 MOUNTING IDUStep 1

    Step 2

    FAN Unit

    Screw (on lower FAN)

    Screw (on upper FAN)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-54.3 Replace MODEM-A/(*)-A CardNote (*)-A: STM1-A, 16E1-A, GbE-A, MSE-A and AUX-A cards; the

    procedures for replacing these cards are the same as that for MODEM-A card, except for the PWR switch that only MODEM-A has.

    Procedure 4-3 Replace MODEM-A/(*)-A Cards

    1 Set the MD PWR switch on the MODEM-A card to OFF position.

    2 Dismount the defective MODEM-A(*) card as shown below:

    Using the screwdriver, loosen two screws.

    Screw

    ScrewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-6 MOUNTING IDU Holding the screws, pull the MODEM-A off from the slot.

    3 Mount a new MODEM-A(*) card as shown below:

    Place the card on the card slot guides of the chassis, then carefully push the card till it is fully engaged to the chassis backboard.NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-7 Ensure not to touch any interfacing parts, carefully insert the card further into the slot.

    Using the screwdriver, secure the card by tighten the screws.

    Warning: Ensure not to touch electrical devices on the card.

    Screw ScrewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-8 MOUNTING IDU4.4 Replace MC-M CardProcedure 4-4 Replace MC-M Card

    NOTE: Before starting the procedure, check if the MC-M Card to be removed has its associated MC-M:

    If the MC-M Card to be removed is unprotected, or is protected but the last remaining of the two, turn off the power of MODEM-A Card before starting the procedure.

    If the MC-M Card has its associated MC-M configuring the protection group, ensure that the MC-M to be removed is on the Standby mode, and in the OOS status.

    1 Dismount the defective MC-M card:

    Using the screwdriver, loosen two screws.

    Pull two ejectors on the card outward.

    Ejector

    Ejector

    Screw

    ScrewNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-92 Pull the card out from the slot.

    3 Install a new MC-M card:

    Place the card on the card slot guides of the chassis.

    Carefully insert the card further till it is fully engaged, and press the two ejectors on the card to lock them.

    iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-10 MOUNTING IDU(1) Using the screwdriver, tighten the screws.

    Warning: Ensure not to touch electrical devices on the card.

    Screw

    ScrewNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-114.5 Replace CLK2M-C CardTo replace the defective CLK2M-C Card on the MC-M Card, proceed with the following:

    Procedure 4-5 Replace CLK2M-C Card

    1 Dismount MC-M Card following Procedure 4-4 Replace MC-M Card.

    2 Dismount CLK2M-C Card:

    Remove the screw that secures the CLK2M-C Card on MC-M Card.

    Warning: Ensure not to touch electrical devices on the card.

    Screwsecuring CLK2M-C CardiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-12 MOUNTING IDU Refering to the illustration below, remove the screw that secures the spacer from the rear surface.

    Dismount CLM2M-C Card.

    Warning: Ensure not to touch electrical devices on the card.

    3 Mount CLK2M-C Card:

    Place the spacer on surface of the MC-M Card.

    Spacer

    CLK2M-C Card

    Screw securing the spacerNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-13 Tighten the spacer using the screw from the rear surface of MC-M Card.

    Set the CLK2M-C Card on the connector provided on the MC-M Card.

    Secure the CLK2M-C card using the screwdriver and screw.

    Spacer

    CLK2M-C Card

    iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-14 MOUNTING IDU4 Verify the installed CLK2M-C Card.

    Warning: Ensure not to touch electrical devices on the card.

    5 Mount MC-M Card following Procedure 4-4 Replace MC-M Card.

    CLK2M-C CardNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-154.6 Replace PS-M CardProcedure 4-6 Replace PS-M Card

    1 Power off the equipment:

    Disconnect the power cable(s) from PS-M Card(s).

    Confirm that the PWR LED lamp(s) is/are off.

    2 Dismount the defective PS-M card:

    Using the screwdriver, loosen the screws.

    Power Cable port PWR LED on PS-M Card 1 Power Cable port

    on PS-M Card 2

    PWR LED

    Screw ScrewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-16 MOUNTING IDU Holding the screws, pull the card out from the slot.

    3 Mount a new PS-M card:

    Place the card on the card slot guides of the chassis.NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-17 Suspend the screws by pulling them outward.

    Ensure not to touch interface parts, insert the card further till it is fully engaged with the chassis backboard.

    Using the screwdriver, tighten the screw.

    Warning: Ensure not to touch electrical devices on the card.

    4 Connect the Power Cable to turn on the power.

    Screw

    ScrewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-18 MOUNTING IDU4.7 Replace PS-M FuseProcedure 4-7 Replace PS-M Fuses

    1 Dismount the PS-M card following Procedure 4-6 Replace PS-M Card.

    2 Remove the defective Fuse:

    Remove the protective cover of the fuse.

    Remove the fuse.

    3 Set a new fuse.

    4 Set the protective cover.

    Warning: Ensure not to touch electrical devices on the card.

    NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-194.8 Replace TERM-M CardProcedure 4-8 Replace TERM-M Card

    1 Power off the equipment:

    Disconnect the power cable(s) from PS-M Card(s).

    Confirm that the PWR LED lamp(s) is/are off.

    2 Dismount the defective TERM-M card:

    Disconnect the cables if connected.

    Using the screwdriver, loosen the screws.

    Power Cable port PWR LED on PS-M Card 1 Power Cable port

    on PS-M Card 2

    PWR LED

    TERM-M Card

    ScrewScrewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-20 MOUNTING IDU Holding the screws, pull the card out from the slot.

    3 Mount a new TERM-M card:

    Place the card on the card slot guides of the chassis. Suspend the screws by pulling them outward.

    Ensure not to touch interface parts, insert the card further till it is fully engaged NWD-118789-04E iPASOLINK 1000: INSTALLATION

    with the chassis backboard.

  • MOUNTING IDU 4-21 Using the screwdriver, tighten the screws.

    Warning: Ensure not to touch electrical devices on the card.

    4 Connect cables back in place to TERM-M Card, if required.

    5 Connect the Power Cable(s) to PS-M Card(s) to turn on the power.

    ScrewScrewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-22 MOUNTING IDU4.9 CWDM Filter Box

    Important: Between the associated sites, a CWDM Filter Box A in one site, and CWDM Filter Box B in the other site must be installed in pair for the use of designated IN and OUT ports. See 7.3.6 Cables Using CWDM Filter Boxes for reference.

    4.9.1 IDU and Filter Box MountCWDM Filter Box can be installed in to the Universal Slots, but it has no back pins to connect with IDU. Thus, CWDM can also be placed out of the IDU using a Filter Box Mount (a dedicated chassis for CWDM Filter Box) if no vacant slot is found in the IDU.

    CWDM Filter Boxes in IDU (Example)

    CWDM Filter Boxes in Filter Box MountNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING IDU 4-234.9.2 Mount CWDMF

    Since CWDM Filter Box has no back pins, installing it either on IDU or Filter Box Mount requires to secure the CWDM Filter Box using two screws only:

    Insert the CWDMF into the Card Slot, and fasten two screws:

    Screw

    ScrewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-24 MOUNTING IDU4.10 Mount SFP Module

    4.10.1 SFP Module

    The Small Form-factor Pluggable (SFP) is a compact and hot-pluggable transceiver designed to support Gigabit Ethernet (GbE) and/or SDH (STM-1) in the iPASOLINK.

    iPASOLINK offers the following five options for SFP modules:

    1) Single Mode Fiber (SMF): This SFP complies with GbE along with SDH. The SFP operates with the 1310 nm laser transmitter and has a duplex LC connector.

    2) Multi Mode Fiber (MMF): This SFP complies with 1.25 Gbps 1000 BASE-SX Gigabit Ethernet. The SFP operates with the laser transmitter and has a duplex LC connector.

    3) Electrical SFP (RJ45): This SFP complies with 10/100/1000 BASE-T copper interface.

    Note SyncE function is not supported on Electrical SFP.

    4) Electrical SFP (DIN 1.0/2.3): This SFP complies with STM-1e SDH interface.

    5) Colored SFP: See 4.10.2 Colored SFP Module.

    The SFP modules also accept LC fiber connectors with Polished Connector (LC-PC) or Ultra Polished Connector (LC-UPC).

    For the purpose of the use in iPASOLINK, it is recommended to use SFPs that are

    SFP Module Ports [MC-M]

    [SFP Module Ports when GbE-A Card(s) is/are mounted.]

    SFP Module Ports [STM1-A on any Universal Slot]NWD-118789-04E iPASOLINK 1000: INSTALLATION

    designated and supplied by NEC.

  • MOUNTING IDU 4-254.10.2 Colored SFP Module

    For the use of CWDM, following SFP are provided. Depending on the applicable wavelength, a colored tape is applied on the extraction lever of each SFP:

    Table 4-1 Types of SFP and Colors

    Wavelength Color Indication on Extraction Lever

    1470 nm Gray

    1490 nm Violet

    1510 nm Blue

    1530 nm Green

    1550 nm Yellow

    1570 nm Orange

    1590 nm Red

    1610 nm Brown

    EXTRACTION LEVER iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 4-26/END MOUNTING IDUProcedure 4-9 Mount SFP Module (Example: IDU)

    1 Mount an SFP module onto the SFP port till it clicks and is fully engaged:

    SFP modules are mountedNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-15. MOUNTING ODU

    The procedures for mounting and dismounting the ODU are described here. There are two types of mounting for the Antenna Direct Mounting type and Feeder Connecting type. The ODU should be installed in the radio station.

    The tools for installation are listed in Table 5-1.

    Caution1. How to use small and large O-rings are shown in following table. Two

    (small and large) O-rings are attached in 18 to 42 GHz band Andrew/RFS direct mount antenna. 11/13/15 GHz band antenna does not have small O-ring (Small O-ring is not used for Andrew/RFS direct mount antenna). If the small O-ring is used for ODU direct mount installation, a gap may occur between ODU and antenna for RF interface. Therefore it may happen transmit or receive level down.

    2. Do not apply silicon grease at O-ring.

    Note 11/13/15 GHz antenna for direct mount is not possible to connect the ordinary waveguide flanges.

    Table 5-1 Tools

    Tools

    Wrench or Monkey Wrench

    Screwdriver

    Torque Wrench

    SystemAttachment Position of

    O-ring (Between:)

    O-ringRemarks

    Small Size Large Size

    1+0 ANT ODU Not used Used Antenna direct mountingANT WG/ODU(18 42 GHz BAND)

    Used Not used Waveguide connection

    1+1 ANT Hybrid/Coupler Not used Used Antenna direct mountingANT WG/Hybrid/Coupler(18 42 GHz BAND)

    Used Not used Waveguide connectioniPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-2 MOUNTING ODUNotes1. Do not use both small O-ring and large O-ring simultaneously.

    2. O-ring size is different with frequency band as follows:

    Position of large sizeO-ring

    Position of small sizeO-ring

    For Waveguide Connection For Antenna Direct Mounting

    ANDREW Antenna

    Position oflarge sizeO-ring

    Position of small sizeO-ring

    RFS Antenna

    For Waveguide Connection For Antenna Direct Mounting

    32mm

    35mm

    Large Size O-ring for Antenna Direct Mounting26-42 GHz Band

    40mm

    10-11 GHz Band 13-23 GHz Band

    4 m

    m

    4 m

    m

    4 m

    m

    18/23 GHz Band 32/42 GHz Band

    15.6m

    m

    Small Size O-ring for Waveguide Connection

    10.8m

    m

    1.8

    mm

    1.8

    mmNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-35.1 Antenna Direct Mounting

    5.1.1 Basic Installation for Antenna & ODU

    Note The details are referred to the installation manual which is attached to the antenna.

    Installation of Bracket

    1 Install the bracket to the antenna pole,

    2 Mount antenna to the bracket,

    ANDREW pole mount bracket for other reflector type

    Washer

    Note *: Tightening torque of 22 Nm for M10.

    Three(3) screws*(Apply screwtight to threads before fitting to antenna)

    Nut*

    Protective capLock washer

    ANDREW pole mount bracket for 1 or 2 ft reflector type

    Lock washerWasher

    Nut

    Clamp BracketiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-4 MOUNTING ODURFS SB1 Type BracketNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-5Note The values in the following table are valid for screws and bolts which have been greased according to the installation instructions.

    Torques for RFS

    Bolt M5 5 Nm

    M6 8 Nm

    M8 17 Nm

    M10 35 Nm

    M12 50 Nm

    U-Bolt, V-Bolt (Pipe mount & safety collar) M10 20 Nm

    Hexagonal brass nut of fine adjustment (Azimuth, Elevation) M8 5 Nm

    M10 10 Nm

    M12 17 Nm

    Hexagonal socket stainless steel screws (Feed systems install on aluminium mounting plate)

    M3 0.2 Nm

    M4 0.4 Nm

    ExceptionsFixing screw of the azimuth fine adjustment spindle M8 x 30 8 Nm

    M12 x 55 17 Nm

    Special application: NOT greasedFixing screw of the plastic radome B4.2 3 NmiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-6 MOUNTING ODUPipe diameter: 48-114 mm

    RFS C-Mount Type Bracket

    Mount Assembly (RFS C-Mount Type)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-7RFS C-Mount Type Bracket

    6

    7iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-8 MOUNTING ODU3 Fix the ODU to the bracket by tightening the M6 screws (four locations),

    Notes1. Being careful, tighten alternately and gradually four screws.

    2. Figure shows V polarization.

    3. Be careful not to damage the O-ring (Antenna).

    4. The tightening torque is 4.0 Nm 10%.

    O-ring

    Hole for guide pin

    ANDREW VHLP Type Bracket

    ODU (6-11 GHz) ODU (13-42 GHz)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-9Notes1. Figure shows V polarization.

    2. Be careful not to damage the O-ring (Antenna).

    3. The tightening torque is 4.0 Nm 10%.

    RFS SB1 Type Bracket

    O-ring

    Hole for guide pin

    ODU (6-11 GHz) ODU (13-42 GHz)

    Note Set the ODU to the bracket after polarization of the ODU is confirmed.

    O-ring

    RFS C-Mount Type Bracket

    Hole for guide pin

    ODU (6-11 GHz) ODU (13-42 GHz)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-10 MOUNTING ODU4 Insert guide pin on the hole of bracket to set the position of screws,

    Caution Align flanges on antenna and ODU correctly, and fix the ODU with four screws.

    5 Fix the ODU to the bracket with four screws.

    Note Tightening torque is 4.0 Nm 10%.

    Guide pin

    ODU

    ODU flangeAntenna flange

    Antenna

    Screws

    Screws

    Screws

    ScrewsODU (6-11 GHz)

    ODU (13-42 GHz)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-11Note Antenna separation (S) is given by path calculation depending on the system parameter.

    1+1 SD System

    Pole

    (S)

    Member of tower

    1+0 System

    Member of tower

    Pole

    No.1 ODU

    No.2 ODU

    ODU

    ODU (6-11 GHz)

    1+0 System

    Member of tower

    Pole

    ODU

    ODU (13-42 GHz)1+1 SD System

    ODU (6-11 GHz)

    ODU (13-42 GHz)

    Pole

    (S)

    Member of tower

    No.2 ODU

    No.1 ODUiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-12 MOUNTING ODU Procedure 5-1 Change of Polarization of Antenna

    (1) ODU Direct Mounting Type Antenna (ANDREW Example #1)

    Notes1. The details are referred to the installation manual which is attached to

    the antenna. The installation or removal of the antenna requires qualified experienced personnel.

    2. The antenna is set to V-polarization when shipped from the factory.

    1 Keep the antenna stand horizontally,

    2 If you change to H polarization, loosen the four screws with the hexagonal key wrench and then rotate the Transition hub of feed, keeping the antenna stand horizontal,

    Note Do not remove the screw complete from the screw hole.Hold the feed horn with hand.

    Transition hub

    2 screws

    2 screwsNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-133 Holding the feed with hand, rotate the feed 90 degrees,

    Check that the aperture part of the Transition hub is rotated 90 degrees, then fix it with the screws that were loosened in Step 2,

    4 Check that the aperture part of the Transition hub is rotated 90 degrees, then fix it with the screws that were loosened in Step 2.

    Note When a large and a small gasket are included in the antenna package. Please use the large one. (The small gasket is not used in antenna mount.)

    (2) ODU Direct Mounting Type Antenna (ANDREW Example #2)

    Notes1. The details are referred to the installation manual which is attached to

    the antenna. The installation or removal of the antenna requires qualified experienced personnel.

    2. The antenna is set to V-polarization when shipped from the factory.

    1 Keep the antenna stand horizontally,

    2 Loosen six screws with Allen wrench until transition can rotate freely,

    Notes1. Do not remove the screw complete from the screw hole.

    2. Because of the screwtight is applied, the strength to loosen screw is necessary.

    Polarization V

    Polarization H

    Top TopiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-14 MOUNTING ODU3 Rotate the transition hub 90 degrees until timing pin locates in timing concavity.

    Tighten six screws when transition hub is located. (Tightening torque is 5.0 Nm 10%.)

    (3) ODU Direct Mounting Type Antenna (RFS Example)

    Notes1. The details are referred to the installation manual which is attached to

    the antenna. The installation or removal of the antenna requires qualified experienced personnel.

    2. The antenna is set to V-polarization when shipped from the factory.

    Vertical Polarized Application Horizontally Polarized Application

    Transition hub

    Transition hub

    Timing pinTransition hub

    RFS SB1

    1. Unscrew the 4 screws M3 at the refined steel ring,

    2. Hold the feed tightly at the waveguide,3. Rotate carefully the feed 90 degrees,4. Mount the feed to the refined steel ring

    and lock the 4 screws M3.

    1. Loosen the 4 screws M3,2. Hold the feed tightly at the waveguide,3. Rotate the casting plate carefully the

    feed 90 degrees,4. Lock the 4 screws M3.

    RFS C-mount

    Drain plugDrain plugNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-154 screws (M3)

    Polarization V Polarization H

    Antenna top

    Vertical HorizontaliPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-16 MOUNTING ODU Procedure 5-2 Change of Polarization of ODU

    1 When vertical polarization is required, rotate the ODU so as to go up the lug marked with V.

    2 When horizontal polarization is required, remove the guide pin fixed on the lug marked with V.

    3 Screw in the guide pin removed in Step 2 to the screw hole of the lug marked with H.

    4 Rotate the ODU so as to go up the lug marked with H.

    Notes1. When the ODU is mounted on the NEC Hybrid/Coupler, only V

    polarization is applied.

    2. When the waveguide or coaxial cable is connected between the ODU and antenna, the ODU in V polarization for up position is recommended for installation.

    Guide pin

    V-marked Lug

    Guide pin

    H-marked Lug

    V-marked Lug

    UP

    V Polarization

    H-marked Lug

    UP

    H Polarization

    FGIFLMONRX LEV

    FGIFL

    MO

    NR

    X LEV

    V/H Polarization Conversion6-11 GHz ODUNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-17V Polarization

    -I R

    V-marked Lug Guide pin

    UP

    -I

    R

    H-marked Lug Guide pin

    UP

    H Polarization

    V/H Polarization Conversion13-42 GHz ODUiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-18 MOUNTING ODU5.1.2 With Hybrid/Coupler

    This section explains the antenna direct mounting type ODU installation with Hybrid/Coupler.

    Mounting

    Note The details are referred to the installation manual which is attached to the antenna.

    ANDREW VHLP Type Bracket

    Mounting hole for Hybrid/Coupler

    Hole for guide pin

    Note The tightening torque is 4.0 Nm 10%.Be careful not to damage the O-ring (Antenna).

    O-ring

    Hole for guide pin

    O-ring

    RFS SB1 Type Bracket

    RFS C-mount type bracket

    Mounting hole for Hybrid/Coupler

    O-ring

    Hole for guide pin

    Mounting hole for Hybrid/Coupler

    Note The tightening torque is 4.0 Nm 10%.NWD-118789-04E iPASOLINK 1000: INSTALLATION

    Be careful not to damage the O-ring (Antenna).

  • MOUNTING ODU 5-19[A] 10-42 GHz Hybrid/Coupler

    1 Fix the bracket and handle to the Hybrid/Coupler,

    Note Tightening torque is 3.0 Nm 10%.

    2 Check the polarization and install the Hybrid/Coupler to the antenna by tightening the M6 screws (four locations),

    .

    Notes1. Be careful not to damage the O-ring.

    2. Tightening torque is 4.0 Nm 10%.

    Hybrid/Coupler

    HandleM5 head cap screwM5x12 (10ea)

    Bracket

    PUSH

    ANT

    O-ring Hybrid/Coupler

    Flat washer M6 screwGuide pin

    Short plate

    O-ring

    ODU portiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-20 MOUNTING ODU3 Insert the O-rings to the two ODU ports of the Hybrid/Coupler,

    4 Install the two ODUs with hex screws (four locations) using the Allen key wrench.

    Note Be careful not to damage the O-rings (Hybrid/Coupler).

    For 10/11 GHz ODU

    Note Tightening torque is 4.0 Nm 10%.

    O-ring

    ODU

    ODU

    O-ring

    ODUNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-21For 26-42 GHz ODU

    Note Tightening torque is 4.0 Nm 10%.

    O-ring

    ODU

    O-ring

    ODU

    ODU

    ODU

    ODUiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-22 MOUNTING ODUDemounting from Hybrid/Coupler

    1 Loosen the four (or six) bolts fixed the ODU,

    2 Then demount the ODU.

    Note When demounting the ODU from Hybrid/Coupler, mount the attached SHORT PLATE to the demounted port of the Hybrid/Coupler to avoid RF power leaking from the hybrid/coupler and for waterproofing.

    Note Tightening torque is 3.0 Nm 10%.

    Mounting short plate to the ODU port

    Mounting hole for short plate

    Short plateNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-23Change of Polarization of Hybrid/Coupler

    Note The hybrid/coupler is set to V-polarization when shipped from the factory.

    1 If you change the polarization from V to H, loosen two screws, rotate the transition hub and put it to the Hybrid/Coupler,

    Note There are two types Hybrid/Coupler. One uses two pieces transition hubs and another uses one piece.

    2 Then fix it with the two screws that were loosened in Step 1.

    Transition hub

    V Polarization

    Guide pin

    Hybrid/Coupler

    V Polarization H Polarization

    Two Pieces Transition Hub Type

    H PolarizationV PolarizationOne Piece Transition Hub Type

    Cross-recessedhead machine screw

    M2.6 (2ea)

    Cross-recessedhead machine screw

    M2.6 (2ea)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-24 MOUNTING ODU[B] 7/8 GHz Hybrid

    This Hybrid/coupler is designed to be attached to 0.6 to 1.8 m antennas with interface for direct mounting of ODU.

    1 Hybrid assembly

    Note Tightening torque is 3.0 Nm 10%.

    2 Polarization coarse alignment

    Support

    Spring washer M5 (8ea.)

    Hexagon sockethead cap screwM5 x 14 (8ea.)

    Hybrid

    V Polarization H Polarization

    Cross-recessedHead machine screw

    M2.6 (2ea.)

    (Shipment condition)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-253 Installation to antenna

    Note Tightening torque is 4.0 Nm 10%.

    4 Attachment of main ODU

    Note Tightening torque is 4.0 Nm 10%.

    Flat washer M6 (4ea.)

    Hexagon sockethead cap screwM6 x 20 (4ea.)

    Spring washer M6 (4ea.)

    Short plateIn case of removing ODU,attach this short plate to the ODU port.

    Attachment of Short Plate

    Hybrid

    Antennaequally and carefully byTighten the each screw

    wrench at diagonalposition.

    O-ring

    Packing (Supplied by antenna)

    Connection Part Details

    Top View

    NEC ODU(Main ODU)

    Hexagon sockethead cap screw M6

    (Supplied by NEC

    O-ring(Packing)

    V direction of ODU

    with ODU)O-ring (Packing)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-26 MOUNTING ODU5 Attachment of standby ODU

    SS: Stainless steel

    Table 5-2 Hybrid Parts List

    No. Parts Name Qty

    1 Hybrid 1

    2 Support 1

    3 O-ring 2

    4 M5 x 14 Hexagon Socket Head Cap Screw (SS) 8

    5 M5 Spring Washer (SS) 8

    6 M6 x 20 Hexagon Socket Head Cap Screw (SS) 4

    7 M6 Flat Washer (SS) 4

    8 M6 Spring Washer (SS) 4

    V direction of ODU NEC ODU(Main ODU)

    O-ring(Packing)

    NEC ODU(Standby ODU)

    Top ViewNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-27[C] 7/8 GHz Coupler

    This Hybrid/coupler is designed to be attached to 0.6 to 1.8 m antennas with interface for direct mounting of ODU.

    1 Coupler assembly,

    Note Tightening torque is 3.0 Nm 10%.

    2 Polarization coarse alignment

    Support

    Spring washer M5 (8ea.)

    Hexagon sockethead cap screwM5 x 14 (8ea.)

    Coupler

    V Polarization H Polarization

    Cross-recessedHead machine screw

    M2.6 (2ea.)

    (Shipment condition)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-28 MOUNTING ODU3 Installation to antenna

    Note Tightening torque is 4.0 Nm 10%.

    4 Attachment of main ODU

    Note Tightening torque is 4.0 Nm 10%.

    Packing (Supplied by antenna)

    Flat washer M6 (4ea.)

    Hexagon sockethead cap screwM6 x 20 (4ea.)

    Spring washer M6 (4ea.)

    Short plateIn case of removing ODU,attach this short plate t the ODU port.

    Attachment of Short Plate

    Coupler

    Antennaequally and carefully byTighten the each screw

    wrench at diagonalposition.

    O-ring

    Connection Part Details

    Top View

    NEC ODU(Main ODU)

    Hexagon sockethead cap screw M6

    (Supplied by NEC

    O-ring(Packing)

    V direction of ODU

    with ODU)

    O-ring (Packing)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-295 Attachment of standby ODU

    SS: Stainless steel

    Table 5-3 Coupler Parts List

    No. Parts Name Qty

    1 Coupler 1

    2 Support 1

    3 O-ring 2

    4 M5 x 14 Hexagon Socket Head Cap Screw (SS) 8

    5 M5 Spring Washer (SS) 8

    6 M6 x 20 Hexagon Socket Head Cap Screw (SS) 4

    7 M6 Flat Washer (SS) 4

    8 M6 Spring Washer (SS) 4

    V direction of ODU NEC ODU(Main ODU)

    O-ring(Packing)

    NEC ODU(Standby ODU)

    Top ViewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-30 MOUNTING ODU[D] 13/15 GHz Hybrid, 15 GHz Coupler

    This Hybrid/coupler is designed to be attached to 0.2 to 1.8 m antennas with interface for direct mounting of ODU.

    1 Hybrid/Coupler assembly

    Note Tightening torque is 3.0 Nm 10%.

    2 Polarization coarse alignment

    Support

    Spring washer M5 (8ea.)

    Hexagon sockethead cap screwM5 x 12 (8ea.)

    Hybrid/Coupler

    V Polarization H Polarization

    Cross-recessedhead machine screw

    M2.6 (2ea.)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-313 Installation to antenna

    Note Tightening torque is 4.0 Nm 10%.

    4 Attachment of main ODU

    Note Tightening torque is 4.0 Nm 10%.

    Packing (Supplied by Antenna)

    Flat washer M6 (4ea.)

    Hexagon sockethead cap screwM6 x 20 (4ea.)

    Spring washer M6 (4ea.)

    Short plateIn case of removing ODU,attach this short plate t the ODU port.

    Attachment of Short Plate

    Hybrid/Coupler

    Antennaequally and carefully byTighten the each screw

    wrench at diagonalposition.

    O-ring

    Connection part details

    Top View

    NEC ODU(Main ODU)

    Hexagon sockethead cap screw M6

    (Supplied by NEC

    O-ring(Packing)

    V direction of ODU

    with ODU)O-ring(Packing)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-32 MOUNTING ODU5 Attachment of standby ODU

    SS: Stainless steel

    Table 5-4 Hybrid/Coupler Parts List

    No. Parts Name Qty

    1 Hybrid/Coupler 1

    2 Support 1

    3 O-ring 2

    4 M5 x 12 Hexagon Socket Head Cap Screw (SS) 8

    5 M5 Spring Washer (SS) 8

    6 M6 x 20 Hexagon Socket Head Cap Screw (SS) 4

    7 M6 Flat Washer (SS) 4

    8 M6 Spring Washer (SS) 4

    V direction of ODU

    NEC ODU(Main ODU)

    O-ring(Packing)

    NEC ODU(Standby ODU)

    Top ViewNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-33[E] 18/23 GHz Hybrid

    This Hybrid is designed to be attached to 0.2 to 1.8 m antennas with interface for direct mounting of ODU.

    1 Hybrid assembly

    Note Tightening torque is 3.0 Nm 10%

    2 Polarization coarse alignment

    Support

    Spring washer M5 (8ea.)

    Hexagon sockethead cap screwM5 x 12 (8ea.)

    Hybrid

    V Polarization H Polarization

    Cross-recessedhead machine screw

    M2.6 (2ea.)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-34 MOUNTING ODU3 Installation to antenna

    Note Tightening torque is 4.0 Nm 10%.

    4 Attachment of main ODU

    Note Tightening torque is 4.0 Nm 10%.

    O-ring

    Antenna

    Packing (Supplied by Antenna)

    Flat washer M6 (4ea.)

    Hexagon sockethead cap screwM6 x 20 (4ea.)

    Spring washer M6 (4ea.)

    Short plateIn case of removing ODU,attach this short plate t the ODU port.

    Attachment of Short Plate

    Hybrid

    equally and carefully byTighten the each screw

    wrench at diagonalposition.

    O-ring (Packing)

    Connection Part Details

    Top View

    NEC ODU(Main ODU)

    Hexagon sockethead cap screw M6

    (Supplied by NEC

    O-ring(Packing)

    V direction of ODU

    with ODU)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-355 Attachment of standby ODU

    SS: Stainless steel

    Table 5-5 Hybrid Parts List

    No. Parts Name Qty

    1 Hybrid 1

    2 Support 1

    3 O-ring 2

    4 M5 x 12 Hexagon Socket Head Cap Screw (SS) 8

    5 M5 Spring Washer (SS) 8

    6 M6 x 20 Hexagon Socket Head Cap Screw (SS) 4

    7 M6 Flat Washer (SS) 4

    8 M6 Spring Washer (SS) 4

    V direction of ODU

    NEC ODU(Main ODU)

    O-ring(Packing)

    NEC ODU(Standby ODU)

    Top ViewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-36 MOUNTING ODU5.1.3 With TX Span Attenuator

    This section explains the antenna direct mounting type ODU installation with TX Span Attenuator (TX SPAN ATT).

    Mounting

    1 Check the polarization of the antenna connection unit of the TX ATT (Refer to Change of Polarization of TX ATT to be hereinafter described.),

    2 Fix the TX ATT to the antenna by tightening the M6 screws (four locations),

    3 Insert the O-rings to port of the ODU,

    4 Fix the ODU with hex screws (four locations) using the hexagonal key wrench.

    Antenna connection unit

    TX ATT

    Antenna

    Guide pin

    TX ATT

    Flat washer M6 (4ea)

    Packing (Supplied by antenna)

    Installation to Antenna

    1 2

    3 4Note Tightening torque (M6) is 4.0 Nm 10%.

    Hexagon socket head cap screw M6 x 30 (4ea)

    32/42 GHz Band ODU Mounting with TX SPAN ATT (1/2)

    38A

    Tighten the eachscrew equally andcarefully by wrenchat diagonal position.NWD-118789-04E iPASOLINK 1000: INSTALLATION

    Note Be careful not to damage the O-rings (TX ATT).

  • MOUNTING ODU 5-37Attachment of ODUHexagon sockethead cap screw M6(Supplied by NEC with ODU)

    O-ring(Packing)

    O-ring(Packing)

    ODU connection unit

    ODU

    Top View

    Side View

    TX ATTODU

    Antenna

    TOP

    TX ATT

    ODU should be attached by turning V up.

    Note Tightening torque is 4.0 Nm 10%.

    32/42 GHz Band ODU Mounting with TX SPAN ATT (2/2)

    38AiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-38 MOUNTING ODUChange of Polarization of TX SPAN ATT

    Note The TX ATT is set to V-polarization when shipped from the factory.

    1 If you change to H polarization, loosen two screws, rotate the antenna connection unit and put the TX ATT horizontally,

    2 Check that aperture of the connection unit is rotated as shown below, then fix it with the two screws that were loosened in Step 1.

    TX ATT

    Antennaconnection unit

    V Polarization

    Guide pin

    Cross-recessedHead machine screwM2.6 (2ea)

    Plate-1

    H PolarizationV Polarization

    32/42 GHz Band TX SPAN ATT Polarization Change

    Plate-2NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-395.1.4 With Ortho-Mode Transducer

    This section explains the antenna direct mounting type ODU installation with Ortho-Mode Transducer (OMT).

    There are two types of O-rings for antenna mounting to the OMT depending on the frequency band.

    Caution Do not apply silicon grease to O-ring.

    Note O-ring size is different with frequency band as follows:

    Position of large sizeO-ring

    For Antenna Direct MountingRFS Antenna

    Position of large sizeO-ring

    For Antenna Direct Mounting ANDREW Antenna

    32mm

    35mm

    Large Size O-ring for Antenna Direct Mounting

    26-42 GHz Band13-23 GHz Band

    4 m

    m

    4 m

    m

    40mm

    10-11 GHz Band

    4 m

    m

    13-23 GHz Band 42 GHz Band

    15.6m

    m

    Small Size O-ring for Waveguide Connection

    10.8m

    m

    1.8

    mm

    1.8

    mmiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-40 MOUNTING ODUFor the antenna direct mounting of the ODU, following OMT is used.

    Cautions1. For connecting the OMT to the antenna, the circular type waveguide flange

    of the antenna is applied to the system. When the V/H flange is mounted to the antenna, it must be changed to a circular type.

    2. When mounting the ODU to the OMT, confirm the polarization for main master and sub master ODU. The installation of the corresponding ODUs in the opposite station must have the same polarization in order to make into line main master and sub master MODEMs.

    1 Fix the bracket and handle to the OMT,

    Note Tightening torque is 3.0 Nm 10%.

    Frequency Band

    FrequencyRange (GHz)

    Interface WG Inner Dia. (mm)(ANT Side)

    Interface(ODU Side)

    11 G 10.4 11.7 GHz 18.0 NEC Original13 G 12.75 13.25 GHz 15.015 G 14.5 15.35 GHz 13.518 G 17.7 19.7 GHz 10.523 G 21.2 23.6 GHz 9.026 G 24.5 26.5 GHz 8.028 G 27.5 29.5 GHz 7.0

    32 G 31.8 33.4 GHz 6.538 G 37 39.5 GHz 5.542 G 40.5 43.5 GHz 4.8

    M5 head cap screwNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-412 Fix the OMT to the antenna by tightening them with M6 screws (four locations),

    Notes

    1. Be careful not to damage the O-ring.

    2. Tightening torque is 4.0 Nm 10%.

    3 Loosen the two screws and move the short plate if it is fixed to the ODU port (see figure in Step 9),

    4 Set the two ODUs to vertical polarization for OMT mounting. If the guide pin behind the plate marked H is mounted, remove the guide pin,

    Note The ODU should be attached by turning the plate marked V up position for both main master ODU and sub master ODU.

    5 Insert the guide pin removed in Step 4 behind the plate marked V,

    Note Remove the protection metallic plate covering the waveguide hole on ODU.

    ANT

    Flat washer M6Guide pin

    O-ring

    Short plate

    O-ring

    M6 screw

    ODU port

    Guide pin

    Plate marked with ViPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-42 MOUNTING ODU6 Insert the O-rings to the two ODU ports of the OMT (see figure in Step 9),

    7 Insert the guide pin into the hole of the OMT and set the position of screws,

    8 Confirm which polarization is applied to the master ODU.Check the indication of polarization on the upper side of OMT,

    Main Master Sub Master

    Plate marked with V

    UP

    FGIFLMONRX LEV

    FGIFLMONRX LEV

    ODU (10/11 GHz)

    Main Master Sub Master

    Plate marked with V

    UP

    -I R

    -I R

    ODU (13-42 GHz)

    Guide pinNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-439 Fix the two ODUs with hex screws (four locations) using the hexagonal key wrench.

    Note Be careful not to damage the O-rings.

    H Polarization side

    V Polarization side

    Note Tightening torque is 4.0 Nm 10%.

    ODU (10/11 GHz)

    O-ring

    ODU

    Note Tightening torque is 4.0 Nm 10%.

    ODU (13-42 GHz)

    Hex screw

    Hex screw

    Hex screw

    ODU

    ODU

    ODU

    Hex screw

    O-ring

    ODUH Polarization side

    V Polarization side

    O-ring

    ODU

    O-ringiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-44 MOUNTING ODUCautions1. Tighten all screws with lighter torque at first, then full torque as specified.2. When either ODU is demounting for ODU replacing or other reasons, fix the

    attached short plate to the demounted port of the OMT to avoid leaking of RF power from the OMT and for waterproof.

    3. To avoid occurrence of bit errors due to microphonic properties, when installing the sub master ODU, protect the main master ODU from mechanical knocks.

    Note Tightening torque is 3.0 Nm 10%.

    Fixed short plate to ODU port

    Fixing hole for short plate

    Short plateNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-455.2 Feeder Connection

    5.2.1 For Coaxial Cable Connection

    6/7/8GHz ODU MOUNTING BRACKET INSTALLATION

    This mounting bracket is designed in order to install 6/7/8 GHz ODU with N-type connector or waveguide interface to a pole. The diameter of the pole is from 48.5 to 114.3 millimeters.

    SS: Stainless steel

    Note Tightening torque is 4 Nm 10% (M6 screw).Tightening torque is 11 Nm 10% (M8 screw).

    Table 5-6 Mounting Bracket Parts List

    Item Description Qty

    1 Bracket 1

    2 Holder-1 (with Two M6 Taps) 2

    3 Holder-2 2

    4 M8 Stud Bolt (SS) 4

    5 M8 Hexagon Nut (SS) 20

    6 M8 Flat Washer (SS) 8

    7 M616 Hexagon Socket Head Screw (SS) 4

    8 M6 Spring lock Washer (SS) 4

    9 M6 Flat Washer (SS) 4

    10 Cap 4

    11 Band (Cable Clamp) 2

    Mounting BracketiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-46 MOUNTING ODU1 A nut is assembled to a stud bolt until a nut has come to a complete stop,

    Standard Installation Reverse Installation

    Stud bolt M8Hexagon nut M8

    Hexagon nut M8 (4 ea)Stud bolt M8 (2 ea)

    Fixed nut

    Approx. 56 mm

    Holder-1

    Flat washer M8 (2 ea)

    Note Tightening torque is 11 Nm 10%.

    Assembly of the Holder-1 (2 sets)

    2 taps M6NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-472 Fix the two holder-1 to the bracket at four bolts,

    3 Mount the bracket to the pole, point to the opposite station and tighten it with four stud bolts,

    Note Since a bolt projects from a holder when a pole diameter is small, please

    Assembly of the BracketHolder-1 assembly

    Bracket

    Flat washer M6 (4 ea)Spring lock washer M6 (4 ea)Hexagon socket head screw M616 (4 ea)

    Note Tightening torque is 4 Nm 10%.

    Pole ( 48.5 to 114.3 mm)

    Note Tightening torque is11 Nm 10%.

    Holder-2 (2 ea)

    A = B

    A

    B

    Installation to the Pole

    Holder

    Bolt end

    Cap (4 ea)

    Hexagon nut M8 (8 ea)

    Flat washer M8 (4 ea)iPASOLINK 1000: INSTALLATION NWD-118789-04E

    attach the cap to a bolt end.

  • 5-48 MOUNTING ODU4 Mount the ODU on to the bracket and tighten four bolts (M6) at upper and lower parts of the ODU,

    5 Connect the coaxial cable to the RF IN/OUT connector of the ODU,

    6 Install the coaxial cables between the antenna and the ODU.

    Notes

    1. Fix the coaxial cable to the pole or member with band (cable ties) after antenna orientation has been completed.

    2. Wrap the coaxial cable connection points with a self-bonding tape for waterproof. (The self-bonding tape shall be prepared by customer.)

    Hexagon socket head screw M6

    Attachment of the ODU

    Note Tightening torque is4 Nm 10%.

    Right angle sideTop View

    Connection of the Coaxial CableExample

    N-type connector

    Band

    Coaxialcable

    Antenna

    Coaxial cable

    Pole

    ODUNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-495.2.2 For Waveguide Connection

    10-42 GHz ODU MOUNTING BRACKET INSTALLATION

    This mounting bracket is designed in order to install 10-42 GHz ODU with antenna direct mount interface to a pole. The diameter of the pole is from 48.5 to 114.3 millimeters.

    SS: Stainless steel

    Note Tightening torque is 4 Nm 10% (M6 screw).

    Table 5-7 Mounting Bracket Parts List

    Item Description Qty

    1 Bracket (with Adapter) 1

    2 Holder-1 (with two M6 taps) 2

    3 Holder-2 2

    4 M8 Stud Bolt (SS) 4

    5 M8 Hexagon Nut (SS) 20

    6 M8 Flat Washer (SS) 8

    7 M616 Hexagon Socket Head Screw (SS) 4

    8 M6 Spring Lock Washer (SS) 4

    9 M6 Flat Washer (SS) 4

    10 Cap 4

    11 O-Ring (for ODU) 1

    12 O-Ring (for Waveguide) 1

    13 Screw of Waveguide Connecting

    for 10/11 GHz M414 Hexagon Head Screw with Washer (SS)

    for 13/15 GHz M412 Hexagon Head Screw with Washer (SS)

    for 18/23/26/28/32/42 GHz M310 Hexagon HeadScrew with Washer (SS)

    8

    4

    4

    Mounting BracketiPASOLINK 1000: INSTALLATION NWD-118789-04E

    Tightening torque is 11 Nm 10% (M8 screw).

  • 5-50 MOUNTING ODU

    1 A nut is assembled to a stud bolt until a nut has come to a complete stop,

    Standard Installation Reverse Installation

    Stud bolt M8Hexagon nut M8

    Hexagon nut M8 (4 ea)

    Stud bolt M8 (2 ea)

    Fixed nut

    Approx. 56 mm

    Holder-1

    Flat washer M8 (2 ea)

    Note Tightening torque is12 Nm 10%.

    Assembly of the Holder-1 (2 sets)

    2 taps M6NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-512 Fix the two holder-1 to the bracket at four bolts,

    3 Mount the bracket to the pole, point to the opposite station and tighten it with four stud bolts,

    Assembly of the Bracket

    Holder-1 assembly

    Bracket (with adapter)

    Flat washer M6 (4 ea)Spring lock washer M6 (4 ea)Hexagon socket head screw M616 (4 ea)

    Note Tightening torque is 4 Nm 10%.

    Pole ( 48.5 to 114.3 mm)Flat washer M8 (4 ea)

    Hexagon nut M8 (8 ea)Note Tightening torque is

    12 Nm 10%.

    Holder-2 (2 ea)

    A = B

    A

    B

    Installation to the Pole

    Holder

    Bolt end

    Cap (4 ea)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-52 MOUNTING ODUNote Since a bolt projects from a Holder when a pole diameter is small, please attach the cap to a bolt end.

    4 Mount the ODU on to the bracket and tighten four bolts (M6) at upper and lower parts of the ODU. Please equip the terminal area of ODU and adapter with O-ring, and join together after that,

    5 When the attachment screw of the ODU is hard, please loosen the fixed four screw of adapter once,

    6 Please adjust the position of adapter to compensate for attachment of ODU. Then tighten four bolts (M6) of the ODU,

    Hexagon socket head screw M6

    Attachment of the ODU

    Note Tightening torque is4 Nm 10%.

    Right angle side

    Adapter

    ODU

    Adapter

    O-ring (for ODU)

    Top View

    Loosen the fixed four screwsAdapter

    BracketNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-537 Connect the waveguide to the adapter of the mounting bracket,

    8 Install the waveguide between the antenna and the ODU.

    Table 5-8 Waveguide Flange Type

    Frequency Band Adapter Waveguide

    10/11 GHz PDR100 PDR100

    13 GHz PBR120 UBR120

    13/15 GHz PBR140 UBR140

    18/23 GHz PBR220 UBR220

    26 GHz PBR260 UBR260

    28/32/42 GHz PBR320 UBR320

    Connection of the WaveguideExample

    Flexible waveguide

    Antenna

    Pole

    ODU

    Flexible waveguideFlexible waveguide O-ring (for waveguide)

    Screw of waveguideconnectingiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-54 MOUNTING ODU5.2.3 For Waveguide Connection with Hybrid

    18/23 GHz Hybrid (FI)

    This Hybrid is designed to be connect to waveguide with interface for direct mounting of ODU. (Waveguide flange type: Hybrid side-PBR220, Waveguide side-UBR220.)

    1 Hybrid assembly

    Tightening Torque

    M3 0.6 Nm 10%

    M5 3.0 Nm 10%

    M6 4.0 Nm 10%

    PUSH HandleHexagon sockethead cap screwM5 12 (10 ea)

    Bracket

    HybridNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-552 Installation to pole mount

    3 Attachment of main ODU

    Hexagon head screwM6 35 (4 ea)*

    Case-1

    Flat washer M6(4 ea)*

    Pole mount

    Flat washer M6 (4 ea)*Hexagon nut M6 (Double) (8 ea)*

    Hybrid

    Short plateIn case you remove ODU,Please attach this Short plateto the ODU port.

    O-ring

    Attachment of Short Plate

    Note *: Supplied by pole mount.

    ODU (Main ODU)

    Pole mount

    Hexagon socket headcap screw M6

    ODU should be attached by turning V up.

    O-ring I/D 32(Packing)

    O-ring I/D 32(Packing)

    Connection Part Details

    Top ViewiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-56 MOUNTING ODU4 Attachment of standby ODU

    5 Connection of waveguide

    ODU (Main ODU)

    O-ring I/D 32(Packing)

    ODU (Standby ODU)

    Pole mount

    ODU should be attached by turning V up.

    Top View

    Hybrid

    Flexible waveguideFlange type UBR220

    Pole mount

    O-ring I/D 32(Packing)

    Hexagon head screwwith washer M310 (4 ea)

    Hybrid

    Waveguide flangeFlange type PBR220

    Do not remove.

    *

    Caution*: Please connect the flexible waveguide in the same direction as Hybrid.NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-57Caution Be careful not to damage the Hybrid. Connection part will be damaged if excessive power is applied to the Hybrid by waveguide.

    *: Supplied by pole mount.

    SS: Stainless steel

    6 Installation to mounting bracket

    Table 5-9 Hybrid (Fl) Parts List (for Mounting Bracket)

    No. Parts Name Qty

    1 Hybrid (Waveguide Flange Interface Type) 1

    2 Bracket 2

    3 Handle 1

    4 O-ring Inner Dia. 32 (for ODU) 25 O-ring Inner Dia. 15.6 (for Waveguide) 16 M5 12 Hexagon Socket Head Cap Screw (SS) 14 (4 part for spare.)

    7 M3 10 Hexagon Head Screw With Washer (SS) 4

    * M6 35 Hexagon Socket Head Cap Screw, Nut, Washer Set (SS) 4

    Case-2

    Mounting bracketShort plateIn case you remove ODU, Please attach this Short plate to the ODU port. O-ring

    Attachment of short plateHybrid

    Hexagon head screw M6 20 (4 ea)Flat washer M6 (4 ea)iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-58 MOUNTING ODU7 Attachment of main ODU

    8 Attachment of standby ODU

    Mounting bracket

    O-ring I/D 32(Packing)

    Connection part details

    ODU (Main ODU)

    Hexagon socket headcap screw M6

    O-ring I/D 32(Packing)

    ODU should be attached by turning V up.

    Top View

    Mounting bracket

    ODU (Main ODU)

    O-ring I/D 32(Packing)

    ODU (Standby ODU)ODU should be attached by turning V up.

    Top ViewNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-599 Connection of waveguide

    SS: Stainless steel

    Table 5-10 Hybrid (Fl) Parts List (for Mounting Bracket)

    No. Parts Name Qty

    1 Hybrid (Waveguide Flange Interface Type) 1

    2 Bracket 2

    3 Handle 1

    4 O-ring Inner Dia. 32 (for ODU) 25 O-ring Inner Dia. 15.6 (for Waveguide) 16 M5 12 Hexagon Socket Head Cap Screw (SS) 14 (4 part for spare.)

    7 M6 20 Hexagon Socket Head Cap Screw (SS) 4

    8 M6 Flat Washer (SS) 4

    9 M3 10 Hexagon Head Screw With Washer (SS) 4

    Hybrid

    Waveguide flangeFlange type PBR220

    Do not remove.

    *

    Mounting bracket

    O-ring I/D 15.6(Packing)

    Hexagon head screwwith washer M3 10(4 ea)

    Flexible waveguideFlange type UBR220

    Caution*: Please connect the flexible waveguide in the same direction as Hybrid.iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-60 MOUNTING ODU5.3 Other Mounting

    5.3.1 Wall Mounting

    For the antenna direct mounting type ODU, wall mounting installation is explained in following procedure.

    1 Using a center punch and hammer, mark the drilling holes for the ODU wall mount bracket. Dimensions are shown below,

    2 Using an electric drill for concrete, drill the guide holes,

    3 Change the concrete drill to enlarge the holes and drill the anchor bolt holes,

    2

    1

    1

    Unit: mm

    Wall

    L

    L

    D

    M10

    L

    DNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-614 Remove debris from the specified hole and insert a plug-bolt into it,

    5 Make sure to insert the plug-bolt fully,

    6 Tighten hardly the bolt using a wrench or monkey wrench,

    Note Anchor bolts of M10 bolt shall be prepared by the customer.

    7 Loosen the bolt and remove it,

    Anchor bolt

    Bolt

    WasheriPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-62 MOUNTING ODU8 Fix the ODU wall mounting bracket to the wall with the six bolts (M6) of the anchor volt,

    Note The bolt, flat washer and spring washer are the anchor bolt.

    9 Mount the ODU onto the bracket and fix the ODU using the four bolts (M6) on the ODU,

    Note The tightening torque is 4.0 Nm 10%.

    Flat washer*Spring washer*

    Bolt*Flange adaptor

    Guide pin(V)

    TransducerTransducer

    Guide pin(V)

    ODU (13-42 GHz)ODU (10/11 GHz)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-6310 Connect the wave guide to the transducer for the ODU.

    Notes

    1. Tightening torque is 1.4 Nm 10% (up to 15 GHz). Tightening torque is 0.6 Nm 10% (18 GHz or higher).

    2. Be careful not to damage the O-ring.

    Refer to 5.2.2 ODU Mounting for Waveguide Connection.

    Washer

    O-ring

    Bolt (M4)Spring washer

    ODU 10/11 GHz)

    Waveguide

    A

    Washer

    O-ring

    Bolt(M4)Spring washer

    ODU 13-42 GHz)

    Waveguide

    For 13-42 GHz

    Details of A

    For 10/11 GHz

    AiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-64 MOUNTING ODU5.3.2 Rack Mounting

    For the antenna direct mounting type ODU, rack mounting installation is explained in following procedure.

    1 Fix the ODU rack mounting bracket into the 19-inch rack using the six fixing bolts,

    2 Mount the ODU onto the bracket and tighten the four fixing bolts (M6) on the ODU,

    Note The tightening torque is 4.0 Nm 10%.

    ODU mounting bracket

    Bolt

    Spring washerFlat washer

    19-inch rack

    Flange adaptor

    ODU

    Guide pinNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • MOUNTING ODU 5-653 Connect the wave guide to the transducer for the ODU.

    Notes

    * M4: Up to 15 GHz.M3: 18 GHz or higher.

    1. Tightening torque is 1.4 Nm 10% (up to 15 GHz). Tightening torque is 0.6 Nm 10% (18 GHz or higher).

    2. Be careful not to damage the O-ring.

    Refer to 5.2.2 ODU Mounting for Waveguide Connection.

    Washer

    O-ring

    Waveguide

    Bolt*Spring washer

    ODU

    A

    For 13-42 GHz

    Details of A

    For 10/11 GHziPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 5-66/END MOUNTING ODU5.4 Hybrid Combiner InstallationWhen you attach two Hybrids to one dual pole antenna, for 1+1 or 2(1+1) system in 6/7/8 GHz rotate the antenna 90 degree counter clockwise, as shown below, to avoid hitting the hybrids to the antenna pole and its structures if necessary.

    .

    WG flangeTo ODU

    To ODU

    Rotate counterclockwise 90degrees.

    LOW LOSS cableNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-16. ADJUSTING CABLE ENDS

    Following provides the list of tools, materials and the method for cable termination. The applicable cables are listed in Table 6-1.

    Notes

    1. For the 1+1 system, the difference between the No.1 channel I/F cable length and the No.2 channel I/F cable length should be within 100 m. (differential absolute delay time: within 500 ns)

    2. When the N (Male) straight connector is attached to the I/F cable, use of the TNC (Male) - N (Female) (NJ-TNCP-LA) L-angle adapter is needed to connect to the IDU.

    3. Use shielded cables which are connected to the D-Sub/RJ-45 connector to suppress interference from affecting the signal and to reduce electromagnetic radiation which may interfere with other signal cables.

    Table 6-1 List of Applicable Cable

    Applicable Cable Connector Type Model# Procedure#

    5D CoaxialCable

    for IDU TNC-P L-angle TNC150(R0) Procedure 6-1for IDU TNC-P L-angle 300PTR-C-NC Procedure 6-2for IDU TNC-P L-angle TNC156(R0) Procedure 6-3for ODU N-P L-angle 300PNR-C-NC Procedure 6-4for ODU N-P Straight 300PNM-C-NC Procedure 6-5for ODU N-P Straight N435(R0) Procedure 6-6

    8D Coaxial Cable

    for IDU TNC-P L-angle TNC141(R0) Procedure 6-7for ODU N-P L-angle N-LP-8DFB(B) Procedure 6-8for ODU N-P Straight N416(R0) Procedure 6-9

    Other Cables for power supply AMP Housing & socket contacts

    AMP: 1-178288-4 or DK-3100S-04R

    Procedure 6-10

    for 120 ohms balanced signal

    D-sub Crimping --- Procedure 6-11

    for auxiliary signal D-sub High Density --- Procedure 6-12iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-2 ADJUSTING CABLE ENDSThe necessary tools and materials are summarized in Table 6-2.

    Table 6-2 Tools and Materials List

    No. Name Remarks

    1 Knife

    For IF coaxial connector

    2 Measure/Ruler

    3 Cutter

    4 Nipper

    5 File

    6 Spanner (14 mm, 16 mm)

    7 Torque spanner (14 mm, 15 mm, 16 mm)

    8 Clearance gauge

    9 Comb

    10 Tweezers

    11 Scissors

    12 Hand Crimping Tool

    91558-1 For power supply connector

    TC-CD-111TC-CD-112

    For D-Sub connector

    09 88 999 0596 For D-Sub high density connectorNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-36.1 5D Coaxial CableProcedure 6-1 TNC-P Connector used for IDU IF IN/OUT (L-angle: TNC150(R0))

    1 Inset parts, remove cable jacket:

    (1) Inset the clamp nut as shown below.

    (2) Remove the cable jacket for 8 mm to the end.

    Note Ensure not to damage the braided wires.

    Tools knife, cutter, nipper, tweezers, file, measure,

    clearance gauge, etc. spanner, torque spanner 14 mm

    Tools knife cutter

    Outlines of parts [Applicable cable: 5D-FB-E]

    Cable jacket Aluminum tape

    Braided wire InsulatorCenter conductor

    Connector body Clamp Clamp nut

    Cable

    Clamp nut(8 mm) *Cut the jacket edge squarely.iPASOLINK 1000: INSTALLATION NWD-118789-04E

    measure, etc.

  • 6-4 ADJUSTING CABLE ENDS2 Inset parts:

    (1) Inset the clamp as shown below.

    (2) Turn the braided wires back to the clamp side.

    Clamp

    Bad Example

    The braids are uneven.

    Braided wire

    Insulator

    Aluminium tape

    Center conductorNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-53 Remove braided wires and insulator:

    (1) Cut the insulator and an aluminium tape along the end face of braided wires that are turned up.

    Note Ensure not to damage the braided wires and the center conductor.

    Aluminium tape

    Insulator

    Center conductoriPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-6 ADJUSTING CABLE ENDS(2) Cut the braided wires according to a flange of clamp.

    Tools cutter nipper

    2)

    Center conductor1)

    Flange

    Braided wire

    Flange Aluminium tape

    Center conductor

    2)

    1)NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-74 Trim the center conductor:

    (1) Remove the center conductor as shown below.

    (2) Chamfer the center conductor.

    Note Ensure not to damage the center conductor (burr, etc.).

    Tools nipper file, etc.

    Center conductor

    1 mm

    6 mm 1

    Center conductoriPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-8 ADJUSTING CABLE ENDS5 Assemble connector:

    (1) The cable center conductor must be straight and aligned with the connector inner contact. Insert the cable into the connector body until it stops.

    (2) Secure the connection to the torque value of 9 to 11 Nm.(Refer to Steps (a) through (e).)

    (a) Hold the cable and connector body.

    Connector body

    Clamp nutNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-9(b) Secure the clamp nut only by fingers.

    (c) Hold the connector body by the spanner.

    (d) Hold the cable.

    * Keep holding the cable.Do not rotate connector body.iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-10 ADJUSTING CABLE ENDS(e) Set a torque spanner.Secure the clamp nut only by the torque spanner.Secure the connection to the torque value of 9 to 11 Nm.

    Notes

    1. Ensure not to put chips or shreds that are off from the braided wires into the inner side of the central conductor and the connector body.

    2. Do not rotate the cable or connector body alone; Rotate the clamp nut attachment.

    Tools spanner (14 mm) torque spanner (14 mm) clearance gauge, measure

    Holding only

    14 mm 9-11 Nm 14 mmNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-11Procedure 6-2 TNC-P Connector used for IDU IF IN/OUT (L-angle: 300PTR-C-NC)

    1 Remove the cable jacket:Remove the cable jacket for 6.5 mm to the end, and expose the braided wires.

    Note Ensure not to damage the braided wires.

    2 Trim the braided wires 1

    (1) Fold the braided wire around jacket.

    (2) Remove the insulator for 5.0 mm to the end.

    (3) Cut off the surplus of insulator/tape from the center conductor.

    Tools knife, cutter, nipper, tweezers, file, comb,

    measure, clearance gauge, etc. spanner, torque spanner; 16 mm, 15 mm

    Tools knife cutter measure, etc.

    [Applicable cable: 5D-FB-E]Outlines of parts

    Cable jacket Aluminium tape

    Braided wire InsulatorCenter conductor

    Connector body Parts A Parts B

    A B

    6.5 mmiPASOLINK 1000: INSTALLATION NWD-118789-04E

    Note Ensure not to damage the center conductor.

  • 6-12 ADJUSTING CABLE ENDS3 Inset parts:

    Twist the braided wires at the end and make them thinner.As revolving parts B and A, insert them onto the cable carefully, not to damage the braided wires.

    4 Trim the braided wires 2

    (1) Using forceps, trim the braided wires to make them straight and equally spaced.

    (2) Fold the braided wires around the part A.

    Tools cutter measure etc.,NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-13(3) Cut the surplus of braided wires according to the outer of part A.

    5 Trim the center conductor:Chamfer the center conductor at a 45 angle.

    Note Ensure not to damage the center conductor.

    Tools scissors nipper tweezers

    Tools cutter measure file, etc.

    45

    5.0 mmiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-14 ADJUSTING CABLE ENDS6 Assemble connector

    (1) The cable center conductor must be straight and aligned with the connector inner contact. Insert the cable into the connector body until it stops. Secure the connection to the torque value of 60 to 80 lb-in (6.8 to 9.0 Nm).

    (2) Check the gap between the connector body and clamp nut: Gap should be 0 to 0.5 mm.

    Notes

    1. Ensure not to put chips and shreds that are off from the braided wires into the inner side of the central conductor and the connector body.

    2. Do not rotate the cable or connector body; Rotate the clamp nut attachment.

    Tools spanner (16 mm) torque spanner (15 mm)

    60-80 lb-in(6.8-9.0 Nm)

    0 to 0.5 mmNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-15Procedure 6-3 TNC-P Connector used for IDU IF IN/OUT (L-angle:TNC156(R0))

    1 Inset parts, remove cable jacket:

    (1) Inset the clamp nut as shown below.

    (2) Remove the cable jacket for 8 mm (+1) to the end.

    Note Ensure not to damage the braided wires.

    Tools knife, cutter, nipper, tweezers, file, measure,

    clearance gauge, etc. spanner, torque spanner 12 mm, 16 mm

    Tools knife cutter measure, etc.

    Outlines of parts [Applicable cable: 5D-FB-E]

    Cable jacket Aluminum tape

    Braided wire Insulator

    Center conductor

    Connector bodyClamp Clamp nut

    Cable

    Clamp nut (8 mm +1)*Cut the jacket edge squarely.iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-16 ADJUSTING CABLE ENDS2 Inset parts:

    (1) Insert the clamp as shown below.

    (2) Turn the braided wires back to the clamp side.

    Clamp

    Braided wire

    Insulator

    Aluminium tape

    Center conductor

    Bad Example

    Braids are uneven. NWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-173 Remove braided wires and insulator:

    (1) Cut the insulator and an aluminium tape along the end face of braided wires that are turned up.

    Note Ensure not to damage the braided wires and the center conductor.

    (2) Cut the braided wires according to a flange of clamp.

    Tools cutter nipper

    Aluminum tape

    Center conductor

    Braided wire

    Flange

    1)

    2)

    Aluminium tapeiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-18 ADJUSTING CABLE ENDS4 Trim center conductor:

    (1) Remove the center conductor as shown below.

    (2) Chamfer the center conductor.

    Note Ensure not to damage the center conductor (burr, etc.).

    5 Assemble connector:

    (1) The cable center conductor must be straight and aligned with the connector inner contact. Insert the cable into the connector body until it stops.

    Tools nipper file, etc.

    Center conductor

    1 mm

    5 mm 1 Center conductor

    Connector bodyNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-19(2) Secure the connection to the torque value of 10 Nm.

    (3) Check the total length* of the connector:

    * total length: 31.4 to 31.7 mm

    Notes

    1. Ensure not to put chips and shreds that are off from the braided wires into the inner side of the central conductor and the connector body.

    2. Do not rotate the connector body; Rotate the clamp nut attachment.

    Tools spanner (16 mm) torque spanner (12 mm)

    Clamp nut

    12 mm 10 Nm 16 mm

    * 31.4 to 31.7 mmiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-20 ADJUSTING CABLE ENDSProcedure 6-4 N-P Connector used for ODU IF IN/OUT (L-angle: 300PNR-C-NC)

    1 Remove the cable jacket:Remove the cable jacket for 6.5 mm to the end, and expose the braided wires.

    Note Ensure not to damage the braided wire.

    2 Trim the braided wires 1

    (1) Fold the braided wires around the cable jacket.

    (2) Remove the insulator for 5.0 mm to the end.

    Tools knife, cutter, nipper, tweezers, file, comb,

    measure, clearance gauge, etc. spanner, torque spanner; 16 mm,15 mm

    Tools knife cutter measure, etc.

    Outlines of parts Applicable cable: 5D-FB-E][

    Cable jacket Aluminium tape (Connector body) (Parts A)

    A

    (Parts B)

    B

    Center conductor

    InsulatorBraided wire

    Clamp nut

    6.5 mmNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-21(3) Remove the surplus of insulator/tape from the center conductor.

    Note Ensure not to damage the center conductor.

    3 Inset parts:

    Twist the braided wires at the end and make them thinner.As revolving parts B and A, insert them onto the cable carefully not to damage the braided wires.

    4 Trim the braided wires 2

    (1) Using forceps, trim the braided wires to make them straight and equally spaced.

    Tools cutter measure etc.,iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-22 ADJUSTING CABLE ENDS(2) Fold the braided wires around the part A.

    (3) Cut the braided wire according to the outer of part A.

    5 Trim the center conductor:Chamfer the center conductor at a 45 angle.

    Note Ensure not to damage the center conductor.

    Tools scissors nipper tweezers

    Tools cutter measure file, etc.

    45

    5.0 mmNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-236 Assemble connector:

    (1) The cable center conductor must be straight and aligned with the connector inner contact. Insert the cable into the connector body until it stops. Secure the connection to the torque value of 60 to 80 lb-in (6.8 to 9.0 Nm).

    (2) Check the gap between the connector body and clamp nut. A gap should be 0 to 0.5 mm

    Notes

    1. Ensure not to put chips and shreds that are off from the braided wires into the inner side of the central conductor and the connector body.

    2. Do not rotate the connector body; Rotate the clamp nut attachment.

    Tools spanner (16 mm) torque spanner (15 mm)

    60-80 lb-in(6.8-9.0 Nm)

    0 to 0.5 mmiPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-24 ADJUSTING CABLE ENDSProcedure 6-5 N-P Connector used for ODU IF IN/OUT (Straight: 300PNM-C-NC)

    1 Remove the cable jacket:Remove the cable jacket for 6.5 mm to the end, and expose the braided wires.

    Note Ensure not to damage the braided wire.

    2 Trim the braided wires 1

    (1) Fold the braided wire around the cable jacket.

    (2) Remove the insulator for 5.0 mm to the end.

    Tools knife, cutter, nipper, tweezers, file, comb,

    measure, clearance gauge, etc. spanner, torque spanner; 16 mm,15 mm

    Tools knife cutter measure, etc.

    Outlines of parts [Applicable cable: 5D-FB-E]

    Cable jacket Aluminium tape

    Braided wire insulator

    Center conductor

    Connector body Parts A Parts B (Clamp nut)

    6.5 mmNWD-118789-04E iPASOLINK 1000: INSTALLATION

  • ADJUSTING CABLE ENDS 6-25(3) Remove the surplus of insulator/tape from the center conductor.

    Note Ensure not to damage the center conductor.

    3 Inset parts:

    Twist the braided wires to make them thinner at the end.As revolving parts B and A, insert them onto the cable carefully not to damage the braided wires.

    4 Trim the braided wires 2

    (1) Using forceps, trim the braided wires to make them straight and equally spaced.

    Tools cutter measure etc.,iPASOLINK 1000: INSTALLATION NWD-118789-04E

  • 6-26 ADJUSTING CABLE ENDS(2) Fold the braided wire around the part A.

    (3) Cut the braided wires according to the outer of part A.

    5 Trim the cen