INSTALLATION INSTRUCTIONS SERIES 487-AR
Transcript of INSTALLATION INSTRUCTIONS SERIES 487-AR
INSTALLATION INSTRUCTIONS
Phone: (800) 421-6144 • Fax: (800) 582-7501crlaurence.com • usalum.com • crl-arch.com
ALUMINUM
SERIES 487-AR(ACOUSTICALLY-RATED)
DOUBLE GLAZE OFFICE PARTITION SYSTEM
WITH 1-1/2" TRIM
11M0300_7-16-19
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM2crlaurence.com | usalum.com
GENERAL INSTALLATION NOTESRecommended Guidelines For All Installations:1. REVIEW CONTRACT DOCUMENTS. Check shop drawings, installation instructions, architectural drawings, and
shipping lists to become thoroughly familiar with the project. The shop drawings take precedence and include specific details for the project. Note any field verified notes on the shop drawings prior to installing. The installation instructions are of a general nature and cover most conditions.
2. INSTALLATION. All materials are to be installed plumb, level, and true. Install operable windows preglazed only.
3. BENCH MARKS. All work should start from bench marks and/or column lines as established by the architectural drawings and the general contractor with guaranteed accuracy. Working from these datum points and lines determine:a) The plane of the wall in reference to offset lines provided on each floor. b) The finish floor lines in reference to bench marks on the outer building columns. c) Mullion spacing from both ends of masonry opening to prevent dimensional build-up of daylight opening.
4. FIELD WELDING. All field welding must be adequately shielded to avoid any splatter on glass or aluminum. Results will be unsightly and/or structurally unsound. Advise general contractor and other trades accordingly. All field welds of steel anchors must receive touch-up paint (zinc chromate) to avoid rust.
5. SURROUNDING CONDITIONS. Make certain that construction which will receive your materials is in accordance with the contract documents. If not, notify the general contractor in writing and resolve differences before proceeding with work.
6. ISOLATION OF ALUMINUM. Aluminum to be placed in direct contact with uncured masonry or incompatible materials should be isolated with a heavy coat of zinc chromate or bituminous paint (CRL Cat. Nos. BC5GL or BC17A).
7. ACOUSTICAL SEALANTS. Sealants must be compatible with all materials with which they have contact, including other sealant surfaces. Consult with sealant manufacturer for recommendations relative to joint size, shelf life, compatibility, cleaning, priming, tooling, adhesion, etc. It is the responsibility of the Glazing Contractor to submit a statement from the sealant manufacturer indicating that glass and glazing materials have been tested for compatibility and adhesion with glazing sealants, and interpreting test results relative to material performance, including recommendations for primers and substrate preparation required to obtain adhesion. The chemical compatibility of all glazing materials and framing sealants with each other and with like materials used in glass fabrication must be established. This is required on every project.
8. FASTENING. Within the body of these instructions "fastening" means any method of securing one part to another or to adjacent materials. Only those fasteners used within the system are specified in these instructions. Due to the varying perimeter conditions and performance requirements, perimeter and anchor fasteners are not specified in these instructions. For perimeter and anchor fasteners refer to the shop drawings or consult the fastener supplier.
9. BUILDING CODES. Due to the diversity in state/provincial local, and federal laws and codes that govern the design and application of architectural products, it is the responsibility of the individual architect, owner, and installer to assure that products selected for use on projects comply with all the applicable building codes and laws. U.S. Aluminum exercises no control over the use or application of its products, glazing materials, and operating hardware and assumes no responsibility thereof.
10. EXPANSION JOINTS. Expansion joints and perimeter seals shown in these instructions and in the shop drawings are shown at normal size. Actual dimensions may vary due to perimeter conditions and/or difference in metal temperature between the time of fabrication and the time of installation. Gaps between expansion members should be based on temperature at time of installation.
11. COORDINATION WITH OTHER TRADES. Coordinate with the general contractor any sequence with other trades which offset curtain wall installation (i.e. fire proofing, back-up walls, partitions, ceilings, mechanical ducts, converters, etc.)
12. CARE AND MAINTENANCE. Final cleaning of exposed aluminum surfaces should be done in accordance with AAMA 609.1 for anodized aluminum and 610.1 for painted aluminum.
IMPORTANT: READ THIS MANUAL THOROUGHLY BEFORE BEGINNING INSTALLATION
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM3crlaurence.com | usalum.com
HANDLING, STORAGE, AND PROTECTION OF ALUMINUMThe following precautions are recommended to protect the material against damage. Following these precautions will help ensure early acceptance of your products and workmanship.A. HANDLE CAREFULLY.
All aluminum materials at job site must be stored in a safe place, well removed from possible damage by other trades. Cardboard wrapped or paper interleaved materials must be kept dry.
B. CHECK ARRIVING MATERIALS. Check for quantities and keep records of where various materials are stored.
C. KEEP MATERIALS AWAY FROM WATER, MUD, AND SPRAY. Prevent cement plaster or other materials from damaging the finish.
D. PROTECT THE MATERIALS AFTER ERECTION. Protect erected frame with polyethylene or canvas splatter screen. Cement, plaster, terrazzo, other alkaline solutions, and acid based materials used to clean masonry are harmful to the finish. If any of these materials come in contact with the aluminum, immediately remove with water and mild soap.
TABLE OF CONTENTSSYSTEM REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4EXTRUSION IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4PARTS IDENTIFICATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5SOUND RATED DRYWALL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6INSTALLATION NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7CLIP PLACEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8FIXED INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
FIXED LITE FRAME INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Install Fixed Lite Header and Wall Jamb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Install Starter Sill and Sill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Secure Frame to Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Install Intermediate Vertical and Horizontal Mullions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Seal Frame at Corners and Mullions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
GLAZING SEQUENCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Glass Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Install Setting Blocks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Install NP718 Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Install Glass Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
TRIM INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16DOOR FRAME INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Install Door Header and Door Jambs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Install Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Install Trim Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Hang and Adjust Door . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Install Closer (Optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
SEAL INSTALLATION FOR DOORS RATED STC 40 AND ABOVE . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 - 19Install Doorway Gasket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Install Adjustable Door Seal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
DOOR WITH SIDELITE FRAME INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 - 24Install Door Header and Door Jamb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Install Sidelite Header and Wall Jamb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Install Sidelite Jamb at Door and Door Jamb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Install Threshold, Starter Sill and Sill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Secure Frame to Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
SINGLE PANE GLAZING INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 - 26Install Filler at Interior Header and Sill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Install Filler at Interior Jambs and Intermediate Verticals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Install Filler at Interior Intermediate Horizontals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Install Interior Clips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Interior Clip Placement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Hinge Jamb
Door Threshold
Door Head
Sidelite Head
Sidelite Sill
Strike Jamb
Strike Jamb / Fixed Mullion
Intermediate Vertical Intermediate Horizontal
Sidelite Wall Jamb
H
I
I
I I
HH
G
G
D
D D
C
C
A
A
B
B A
E
F
F F
J
J
Single Door and Fixed LitesSingle Door
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM4crlaurence.com | usalum.com
EXTRUSION IDENTIFICATIONYour order has been carefully fabricated, inspected, and packaged to work order specifications. We have placed an Indicator Label on the inside or back side of each part before final packaging. Use the Identification Key (below) to organize and lay out each Series 487 Office Partition System before proceeding with the assembly process. The Key is viewed from the Push Side of the Door.Technical support is available online at crlaurence.com and by phone at (800) 262-5151. Please have your Sales Order Number for easy reference.
SYSTEM REQUIREMENTSMaximum wall thickness: 4-7/8" (124 mm). Maximum unsupported total load on each sill: 50 lbs. (23 kg) each. Note: Additional shim support under the sill member is required for any loads over 50 lbs (23 kg).Interior use only.
ACCESSORY PART NUMBER
487C1 487C2 20061601 SB574
Corner Clip T-Clip Use with 487C1 and 487C2 Clips Setting Block
NP225 NP718 NP238 NP716
Use with 1/4" (6 mm) Laminated Glass
Use with 1/4" (6 mm) Laminated Glass
Use with 3/8" (10 mm) Laminated Glass
Use with 3/8" (10 mm) Laminated Glass
NP600C Pempko #S773 by Others 487RBP5 487RBP6
Door Gasket (Installed)Doorway Gasket Use with Doors
Rated STC 40 and Above Strike Backup Plate Hinge Backup Plate
8X58HWSMS 6X2WD ST242 6X12PHPSMS
Use with MC037 Clip Use with Adjustable Door Seal
MC037
Snap Clip for DS036
EXTRUSION PART NUMBER
487x200 487x201 487x202
Door Frame Head and Jamb Sidelite Head, Sill, and Wall Jamb Starter Sill
487x203 487x208 487x214
Intermediate Mullion Door Frame Insert Glazing Adaptor
487x215 487x216 487x217
1-1/2" Face Cap Threshold Single Pocket Filler
487x218 487x015 DS036
Dual Pocket Filler 1-1/2" Trim Strip Use with Doors Rated STC 40 and Above
Zero #475 by Others
Adjustable Door Seal Body and CoverUse with Doors Rated STC 40 and Above
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM5crlaurence.com | usalum.com
PARTS IDENTIFICATION
NOTE: Use 2-1/2” (64 mm) Steel Studs with two 1/2” (13 mm) Drywall Panels at interior and two 5/8” (16 mm) Drywall Panels at exterior. Separate panels with Green Glue as shown.
INTERIOR
GR
EEN
GLU
E
GR
EENG
LUE
2 2
5/8" (16 mm)Drywall
5/8" (16 mm)Drywall
1/2" (13 mm)Drywall 1/2" (13 mm)
Drywall
11
GREEN
GLUE
GREEN
GLUE
INTERIOR
Run bead of Acoustical Sealant along edge of each Drywall Panel. Run another bead on center of Steel Studs at ceiling and sides.
Apply 1/32” (.8 mm) Green Glue on Steel Studs and install first layer of Drywall Panels.
Apply 1/32” (.8 mm) Green Glue and install second layer of Drywall Panels.2
3
3
1
Acou
stica
lSe
alant
Run bead of Acoustical Sealant along edge of each Drywall Panel and on center of Steel Stud
1/2"
(13
mm
) Dry
wal
l
1/2"
(13
mm
) Dry
wal
l2-1/2" (64 mm)Steel Stud
5/8"
(16
mm
) Dry
wal
l
5/8"
(16
mm
) Dry
wal
l
1/32” (.8 mm)Green Glue
1/32” (.8 mm) Green Glue between Drywall Panels2
3
1EXTERIOR
4-7/8” (124 mm)Finished
2-1/2”(64 mm)Steel Stud
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM6crlaurence.com | usalum.com
SOUND RATED DRYWALL INSTALLATIONFollow instructions below for typical STC 52 rated wall installations. Refer to the CRL shop drawings for overall layout and to confirm dimensions.
Exterior
1/2" (13 mm) Drywall
1/2" (13 mm) Drywall
5/8" (16 mm) Drywall
5/8" (16 mm) Drywall
2-1/2" (64 mm)Steel Stud
Check Measurements. If needed, shave wallboard to finish wall at 4-7/8” (124 mm)
Critical Dimension4-7/8” (124 mm)
Finished
Wallboard Cut Flush toSteel Stud
Critical Dimension4-7/8” (124 mm)
Finished Interior
1/2" (13 mm) Drywall
1/2" (13 mm) Drywall
5/8" (16 mm) Drywall
5/8" (16 mm) Drywall
Nominal Gap1” (25 mm)
Exterior
Acoustical Sealant(by others)
2-1/2" (64 mm)Steel Stud
Acoustical Sealant(by others)
1/2" (13 mm) Drywall
1/2" (13 mm) Drywall
5/8" (16 mm) Drywall
5/8" (16 mm) Drywall
Nominal Gap1” (25 mm)
Exterior
Acoustical Sealant(by others)
2-1/2" (64 mm)Steel Stud
Acoustical Sealant(by others)
487x200 Door Header487x200 Door Jamb at Wall
487x201 Fixed Lite Header487x201 Wall Jamb
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM7crlaurence.com | usalum.com
INSTALLATION NOTESThe 487 Office Partition system requires that all rough openings have a maximum 4-7/8" (124 mm) finished wall thickness.
Maintain a nominal gap to allow for plus or minus adjustments when leveling and plumbing. Use 1" (25 mm) gap for sill, sidelite head and wall jambs and 3/4" (19 mm) nominal gap for door frame at wall.
NOTE: Ensure drywall thickness finishes at a standard 4-7/8" (124 mm). Cut wallboard flush with the metal stud. Ensure drywall is square and plumb.
Unless requested otherwise, all vertical members are cut with an additional 1-5/8" (41.3 mm) scribe length to allow for varying unlevel floor conditions. Do not trim scribe from the notched end of door frame or mitered ends of jambs, glass stops and trim strips.
487x200
487x
200
487x
200Doorway
487C1 487C1
487x216
Fixed LiteFixed Lite
Fixed Lite
487C1 487C1
487C1487C1
487C2
487C2 487C2
487C2
487x201 487x201
487x201487x201487x202 487x202
487x
201
487x
201
487x203
487x
203
487x200
487x
200Sidelite Doorway
487x201
487C1 487C1
487C1 487C1
487C2
487x201487x202 487x216
487x
201
487x
201
487x
208
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM8crlaurence.com | usalum.com
CLIP PLACEMENT
Square and plumb frame. Secure with 487C1 Corner Clips and 20061601 Screws at interior and exterior corners.
487x201Fixed Lite Header
1Acoustical Sealant
Aco
ustic
al S
eala
nt
487x
201
Wal
l Jam
b
2
Aco
ustic
al S
eala
nt
487x
201
Wal
l Jam
b
2
3
3 3
2
1
487C1487C1
487x201
2006160120061601
EXTERIOR
487x
201
487x201
487C1
3
NOTE: Position 487C1 Corner Clips so screws secure frame to drywall.
487C1
487C1
20061601
20061601
3
3
3
3
3
487x201
487x201INTERIOR
Seal inside Header and butter mitered ends with Acoustical Sealant. Level and center Header horizontally in opening.
487x201 487x201
487x201
2 2
1
Butter Mitered End with Acoustical Sealant
Position at Top
Apply Acoustical Sealantto Floor at Jambs
Butter Mitered Ends with Acoustical Sealant
Seal inside Jambs and butter mitered end with Acoustical Sealant. Install at each wall with mitered end at top. NOTE: Apply Acoustical Sealant to floor.
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM9crlaurence.com | usalum.com
FIXED LITE FRAME INSTALLATION Install Fixed Lite Header and Wall Jamb
2
3
Apply Acoustical Sealant to Starter Sill.
Apply Acoustical Sealant to bottom of 487x202 Starter Sill. Center in opening and secure.
Level and secure Sill to Starter Sill at interior and exterior with 20061601 Screws. Space screws 2” (51 mm) from ends and 12” (305 mm) on center.
4
Secure to Jambs at interior and exterior bottom corners with 487C1 Corner Clips and 20061601 Screws.
NOTE: Starter Sill is cut 1/8” (3 mm) shorter than the D.L.O.
1
487x202Starter Sill1
Acoustical Sealant
2
3
Acoustical Sealant487x202
487x201Sill
487x202
487x201
20061601 200616014 4
INTERIOR
487x202
487x201 Fastenersby Others
Appropriatefor
Substrate
Butter Ends withAcoustical Sealant
1 AcousticalSealant
Acoustic
al
Sealant
Acoustic
al
Sealant
2
3
12” (305 mm)on Center
2” (51 mm)from Ends
20061601
20061601
INTERIOR
4
45
5
5
5
487x202
487x201
487x201
487C1
5
4
487C1
487C1
20061601 20061601
20061601
20061601
4
5
5
Butter ends of 487x201 Sill with Acoustical Sealant and install.
5
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM10crlaurence.com | usalum.com
FIXED LITE FRAME INSTALLATION (CONTINUED)Install Starter Sill and Sill
INTERIOR
NOTE: Place screws next to clips at corners. Use fasteners appropriate for substrate.
Fasteners by OthersAppropriate for Substrate
12”(305 mm)on center
2” (50 mm)at ends
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM11crlaurence.com | usalum.com
FIXED LITE FRAME INSTALLATION (CONTINUED)Secure Frame to Wall
NOTE: If no Intermediate Vertical and/or Horizontal Mullions are required, proceed to Frame Sealing on Page 12.
Square and plumb frame. Secure frame to wall at interior and exterior. Space screws 2” (50 mm) from ends and 12” (305 mm) on center.
487x
203
487x203
487C2
22
Install Intermediate Verticals between Sidelite Header and Sill. Square and plumb. Secure with 487C2 T-Clips and 20061601 Screws at interior and exterior top and bottom.
NOTE: Install 487x203 Intermediate Verticals before installing 487x203 Intermediate Horizontals. Butter ends with Acoustical Sealant before installing.
Install Intermediate Horizontals. Square and plumb. Secure with 487C2 T-Clips and 20061601 Screws at interior and exterior sides.
487x203Intermediate Vertical
andIntermediate Horizontal
2006160120061601
487C2 487C2
1
487C2
487C2
20061601
20061601INTERIOR
1
1
1
1
2
2
2
2INTERIOR
487x203
487x201 with 487x202487C2
1
487C2487C2
20061601
20061601
2
1
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM12crlaurence.com | usalum.com
FIXED LITE FRAME INSTALLATION (CONTINUED)Install Intermediate Vertical and Horizontal Mullions
33S ClearSiliconeSealant
33SClear
SiliconeSealant
INTERIOR
Place SB574 Setting Blocks at quarter points in each interior and exterior opening.
487x203Intermediate Horizontal
SB574SB574
SB574
487x202
487x201Sill
SB574
487x
203
487x
201
487x
201
487x201
487x201 with 487x202
487x203
SB574
1/4 1/4 1/4 1/4
SB574
SB574
1/4 1/4
INTERIOR
Glass Size = D.L.O. + 5/8" (16 mm) or allow 5/16" (8 mm) Glass Bite at Each Pocket
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM13crlaurence.com | usalum.com
FIXED LITE FRAME INSTALLATION (CONTINUED)Seal Frame at Corners and MullionsSeal and tool at all corners with 33S Clear Silicone Sealant.
GLAZING SEQUENCE Glass Size
Install Setting Blocks
EXTERIOR
487x201WallJamb
487x201WallJamb
487x203Intermediate
Vertical
NP718NP718
NP718 NP718
1
1 1
14 4
4 4
Silicone frame reglets 2” (51 mm) at corners before installing gasket.
Butt EndsTogether3
1
1
45
2NP718
NP718
Apply RTV408Silicone to Joint
NP718
NP718
Silicone CornersBefore Installing
Gasket
Install GasketBehind Clips
NP718 Gasket Installation Order Silicone and Butt Ends of Gasket
NOTE: Intermediates have two rows of Gaskets. Only one row is shown above.
Jambs
Head
Sill
Intermediate Vertical
Intermediate Horizontal
3
1
45
2
Install NP718 Gasket in pieces in the order shown below. Before inserting gasket, apply Silicone at each corner of frame. Silicone and butt ends of gaskets. Install at interior and exterior.
2”(51 mm)
2”(51 mm)
487x203Intermediate Horizontal
487x202
NP718 NP718
NP718NP718
487x201Fixed Lite Header
487x201Sill
3 3
2 2
5
5
5
5
EXTERIOR
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM14crlaurence.com | usalum.com
GLAZING SEQUENCE (CONTINUED) Install NP718 Gaskets
notch
notch
silicone
start
notch
notch
notch
notch notch
notch
silicone
start
notch
notch notch
notch
silicone
start
487x214
6
Place Glass Panel on Setting Blocks and center in opening. Hold vertical.Insert 487x214 Glazing Bead at Head. Insert 487x214 Glazing Bead at Sill.
Install 487x214 Glazing Bead at Verticals.
Install one panel at a time. Horizontal 487x214 Glazing Beads run through. Install NP225 Gasketin continuous loop for each opening. Cut Gasket 1/8” (3 mm) longer per foot. Crowd into reglet.
Cut NP225 Gasket 1/8” (3 mm) longer per foot and crowd into reglet. Begin at center top and notch at corners. Silicone joint.
Repeat Steps 1 - 7 above to install Exterior Panels.
2
31
5 6
7
8
4
INTERIOR
487x201Header
487x202
487x201Sill 487x214
NP2253
4
INTERIOR
487x201Header
487x202
487x201Sill
2487x214
1/4” (6 mm)Laminated Glass
1
Use 1” (25 mm) pieces of NP225 Gasket near ends of Head to temporarily hold glass.
Use 1” (25 mm) pieces of NP225 Gasket near ends of Sill.
NOTE: Exterior Header to Sill panel shown. Others similar.
NP225
Notch NP225Gasket at Corners
Insert temporary NP225 Gaskets near ends of Panel. Remove when installing continous gasket.
INTERIOR
5
3
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM15crlaurence.com | usalum.com
GLAZING SEQUENCE (CONTINUED) Install Glass Panels
NOTE: Tap 487x215 Trim Plates with rubber mallet and block of wood to install.
NOTE: Tap 487x015 Trim Plate with rubber mallet and block of wood to install at Doorway.
487x
203
487x
201
487x
201
487x
215
487x
215
487x
215
487x
215
487x
215
487x
215
FixedLite
FixedLite
487x015
487x
015
487x
015
Doorway
487x015
487x
015
487x215
487x215
487x
215
487x
215
Sidelite Doorway
487x
201
487x
215
487x
215
487x
200
487x
015
487x
015
487x203
487x201
487x201
487x215
487x215
487x215
487x215
487x215
487x215
Fixed Lite
Fixed Lite
487x200
487x015487x015
Doorway
DoorwaySidelite
Install 487x015 Trim Plates on 487x200 Door Header and Jambs. Install 487x215 Trim Plates on 487x201 and 487x203 members. Position mitered ends as shown below. Notch Horizontal Trim Plates at Intermediate Verticals for 487C2 T-Clips.
487x215
487x215
487x215
487x
215
487x
215
487x
215
Fixed LiteFixed Lite
Fixed Lite
Notch Trim
Notch Trim1/8” (3 mm) x 3/4” (19 mm) Notch at Intermediate Verticals for 487C2 T-Clips.
487x215Notch Trim
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM16crlaurence.com | usalum.com
TRIM INSTALLATION
3
487x200
487C1
487x
200
487x200 Door HeaderAcoustical Sealant
1
NP600CEXTERIOR
487x
200
Doo
r Jam
b at
Wal
lA
cous
tical
Sea
lant
NP600C
2
Aco
ustic
al S
eala
nt
NP600C
EXTERIOR
487x
200
Doo
r Jam
b at
Wal
l
2
3
3 3
Seal inside Door Header and butter mitered ends with Acoustical Sealant. Level and center horizontally in opening.Seal inside Door Jambs and butter mitered end with Acoustical Sealant. Install at each wall with mitered end at top. NOTE: Apply Acoustical Sealant to floor.
2
1
487x200 487x200
Apply Acoustical Sealant to Floor at Jambs
1
Butter MiteredEnds withAcoustical
Sealant2 2
487x200
Square and plumb frame. Secure at interior and exterior corners with 487C1 Corner Clips and 20061601 Screws.
NOTE: Position 487C1 Corner Clips so screws secure frame to drywall.487C1
487x200
487C1
2006160120061601
EXTERIOR
NOTE: Review Pages 6 and 7 to ensure the drywall is properly prepped before beginning.
3
3
3
3
487x200
487x200INTERIOR
3487C1
487C1
20061601
20061601
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM17crlaurence.com | usalum.com
DOOR FRAME INSTALLATIONInstall Door Header and Door Jambs
Apply Acoustical Sealant.
Remove protective liner from back of Doorway Gasket. Install on Door Header and Jambs as shown. Cut at ends 45 degree angle and butt at corners.
NOTE: Threshold is notched for Door Stop.
487x216Threshold
Acoustical Sealant1
Butt endstogether
at corners.
INTERIOR 487x200
487x200
Remove protective liner fromDoorway Gasket.
Cut corners at 45degree angle.
INTERIOR 487x200
487x200487x200
NP600C
7/8”(22 mm)
Doorway Gasket
487x
015
487x
015
EXTERIOR
Fastenersby Others
Appropriatefor Substrate
487x216
INTERIOR
2
1Acoustical
Sealant
487x216
INTERIOR
2
Center Threshold in opening and secure. 21
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM18crlaurence.com | usalum.com
DOOR FRAME INSTALLATION (CONTINUED)Install Threshold
Install Trim PlatesFollow instructions on Page 16.
Hang and Adjust DoorFollow the Installation Instructions included with your door.
Install Closer (Optional)SEAL INSTALLATION FOR DOORS RATED STC 40 AND ABOVEInstall Doorway Gasket
7
6
Install MC037 Clips at Door Header and Jambs with ST242 Screws.
Install Adjustable Seal Body at Door Jambs.
Install Adjustable Door Seal Body at Door Header.
Install Adjustable Door Seal Cover at Door Header.
Seal and tool at corners with 33S Silicone Sealant.
Snap DS036 onto clips at Jambs.
Snap DS036 onto clips at Header.
NOTE: DS036 Verticals run through. DS036 Horizontals butt against verticals.
NOTE: 487x200 Door Frame Head and Jamb shown. 487x208 Door Frame Insert similar.
NOTE: Adjustable Seal Verticals run through. Adjustable Seal Horizontals butt against verticals.
NOTE: Position MC037 Clips so DS036 sits next to Door Stop. Attach with #10 x 1/2” PPH SMS spaced 6” from ends and 18” on center.
NOTE: Position Adjustable Seal to compress 1/8” (3 mm). Fasten with #6 x 1/2” PPH SMS at slotted hole locations.
2
1
487x
200
Doo
r Jam
b
5 4
1/8” (3 mm)Compression
DOOR
2
1
1
3
EXTERIOR
EXTERIOR
EXTERIOR
EXTERIOR
3
4
678
5 Install Adjustable Seal Cover at Door Jambs.
1
3
487x200 Door Header
MC037
ST242
DS036
EX
TER
IOR
21
DS036 MC037ST242 48
7x20
0 D
oor J
amb
EXTERIOR
54
DOOR
7
61/8” (3 mm)
Compression
487x200 Door HeaderEX
TER
IOR
EXTERIOR
8
33S ClearSilicone Sealant
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM19crlaurence.com | usalum.com
SEAL FOR DOORS RATED STC 40 AND ABOVE (CONTINUED)Install Adjustable Door Seal
2
1
Apply Acoustical Sealantto Floor at Jambs
487x200EXTERIOR
487x200
Butter Mitered Ends withAcoustical Sealant
487x200 Door HeaderAcoustical Sealant
1
NP600CEXTERIOR
487x
200
Doo
r Jam
b at
Wal
lA
cous
tical
Sea
lant
NP
600C
EXTERIOR
2
Seal inside Door Header and butter mitered end with Acoustical Sealant. Place mitered end at wall.Seal inside Door Jamb and butter mitered end with Acoustical Sealant. Install at wall with mitered end at top. NOTE: Apply Acoustical Sealant to floor.
2
1
NOTE: Review Pages 6 and 7 to ensure the drywall is properly prepped before beginning.
487x200
487C1
487C1
20061601
20061601
3
3
487x200
487C1
487x
200
3 Align mitered ends. Square and plumb. Secure at interior and exterior corner with 487C1 Corner Clips and 20061601 Screws.
NOTE: Position 487C1 Corner Clips so screws secure frame to drywall.
487C1
487x200
487C1
2006160120061601
EXTERIOR
33
3
3
487x200
487x200
EXTERIOR
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM20crlaurence.com | usalum.com
DOOR WITH SIDELITE FRAME INSTALLATIONInstall Door Header and Door Jamb
EXTERIOR 487x201
2
1
Apply Acoustical Sealantto Floor at Jamb
487x201
487x200
487x
200
Butter Ends withAcoustical Sealant
Align mitered ends. Square, plumb and secure with 487C1 Corner Clips and 20061601 Screws at interior and exterior corners.
3
Seal inside Sidelite Header and butter ends with Acoustical Sealant. Place mitered end at wall. Level and push flush against Door Header.
Seal inside Sidelite Jamb and butter mitered end with Acoustical Sealant. Install at wall with mitered end at top. NOTE: Apply Acoustical Sealant to floor.
487x201Fixed Lite Header
1Acoustical Sealant
EXTERIOR
EXTERIOR
Aco
ustic
al S
eala
nt
487x
201
Wal
l Jam
b
2
2
1
Butt tight againstDoor Header
487x201
487x200
487x200
487x201
EXTERIOR
3
3
487C1
487C1
487C1
20061601
20061601
3
487C1487C1
487x201
2006160120061601
EXTERIOR
33
487x
201
487x201
487C1
3
NOTE: Position 487C1 Corner Clips so screws secure frame to drywall.
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM21crlaurence.com | usalum.com
DOOR WITH SIDELITE FRAME INSTALLATION (CONTINUED)Install Sidelite Header and Wall Jamb
487x200
487C2
487x
208
487x
201
487x201
5
2
3
4
1
EXTERIOR487x200
487x208
487x201
487x201
4
4
5
5
12”(305 mm)on Center
2”(51 mm)
from Ends
Seal inside Sidelite Jamb and butter top end with Acoustical Sealant.
Butt top of Sidelite Jamb against bottom of Sidelite Header at door. Position back of Sidelite Jamb flush with end of Sidelite Header.Fit Door Jamb into Sidelite Jamb with notched end at top.
Square and secure Door Jamb to Sidelite Jamb with 20061601 Screws spaced 2” (51 mm) from ends and 12” (305 mm) on center at interior and exterior.
Secure to Header with 487C2 T-Clips and 20061601 Screws at interior and exterior.
3
487x
208
Doo
r Jam
b
NP
600C
487x
201
Sid
elite
Jam
b
EXTERIOR
ApplyAcousticalSealant to
Floorat Jamb
487x201
2
3
487x208EXTERIOR
Butter Endswith
AcousticalSealant
Align Ends
Aco
ustic
al S
eala
nt
487x
201
Sid
elite
Jam
b
1
EXTERIOR
487C2
487C2
20061601
20061601
4
5
5
5
487x
208
Doo
r Jam
b
NP
600C
487x
201
Sid
elite
Jam
b
2006
1601
2006
1601
4
4
EXTERIOR
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM22crlaurence.com | usalum.com
DOOR WITH SIDELITE FRAME INSTALLATION (CONTINUED)Install Sidelite Jamb at Door and Door Jamb
487x
208
487C1
487x216487x202
487x201
487x
201 7
487C1
20061601
6
7
487C1
20061601 67
2
3
4
6
7
1
Square and secure at interior and exterior bottom Jamb with 487C1 Corner Clips and 20061601 Screws.
Apply Acoustical Sealant.
NOTE: Threshold notched for Door Stop.
487x216 Threshold
Acoustical Sealant
1
487x216
487x208
INTERIOR
2
Center Threshold in opening and secure.
Apply Acoustical Sealant to bottom of 487x202 Starter Sill. Center in opening and secure.
Level and secure Sill to Starter Sill at interior and exterior with 20061601 Screws spaced 2” (51 mm) from ends and 12” (305 mm) on center.
NOTE: Starter Sill cut 1/8” (3 mm) shorter than the D.L.O.
Acoustical Sealant487x202
487x201Sill
4
5
487x202
487x201
20061601 200616016 6
Butter ends of 487x201 Sill with Acoustical Sealant and install.
487x202Starter Sill
Acoustical Sealant
3
5
3
4
487x216
INTERIOR
487x202
AcousticalSealant
AcousticalSealant
AcousticalSealant
487x201
1
AcousticalSealant
2
5
12” (305 mm)on Center
2” (51 mm)from Ends
INTERIOR
6
67
7
7
7
Apply Acoustical Sealant to Starter Sill. NOTE: Fasteners byOthers Appropriate
for Substrate
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM23crlaurence.com | usalum.com
DOOR WITH SIDELITE FRAME INSTALLATION (CONTINUED)Install Threshold, Starter Sill and Sill
12”(305 mm)on center
2” (50 mm)at ends
1
1
1
Fasteners by OthersAppropriate for Substrate
EXTERIOR
1
Secure door frame to frame with 20061601 Screws spaced 2” (50 mm) from ends and 12” (305 mm) on center at interior and exterior.
Square frame and secure to wall at interior and exterior with screws spaced 2” (50 mm) at ends and 12” (305 mm) on center.
NOTE: Place screws next to clips at corners. Use fasteners appropriate for substrate.
2
20061601
12” (305 mm)on center
2” (50 mm) at ends
2
2
EXTERIOR
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM24crlaurence.com | usalum.com
DOOR WITH SIDELITE FRAME INSTALLATION (CONTINUED)Secure Frame to Wall
Follow instructions on Page 13 to install Intermediate Mullions. If no Intermediate Mullions are required, seal and tool joints as shown on Page 14. Continue with glazing on Pages 14 - 16 and Trim Installation on Page 17. Follow steps on Page 19 to prepare and install door.
1
1
487x217
Notch for487C2Clips
487x217
487x217
487x217
200616101
INTERIOR
3
2
1 Install 487x217 Filler at interior Header and Sill. Space 20061601 Screws 2” (51 mm) from ends and 12” (305 mm) on center.
NOTE: Horizontal Fillers butt against Jambs.
NOTE: Notch for Clips. Refer to Clip Placement Chart on Page 25. Adjust screw spacing to avoid Clips.
NOTE: Notch for Clips. Refer to Clip Placement Chart on Page 25. Adjust screw spacing to avoid Clips.
Install 487x217 Filler at interior Jambs. Space 20061601 Screws 2” (51 mm) from ends and 12” (305 mm) on center.
Install 487x218 Filler at interior 487x203 Intermediate Vertical. Space 20061601 Screws 2” (51 mm) from ends and 12” (305 mm) on center.
487x217 1487x201Sidelite Header
20061601
487x202
487x201Sill
487x217 1
20061601
EX
TER
IOR
3
487x
203
Inte
rmed
iate
Ver
tical
2006
1601
487x
218
2
487x
217
2006
1601
487x
201
Sid
elite
Jam
b
2
487x
208
Doo
r Jam
b
NP
600C
487x
201
Sid
elite
Jam
b20
0616
0148
7x21
7
EXTERIOR NOTE: Vertical Fillers fit between horizontal Fillers.
3
2
2
487x217
487x217
487x218
INTERIOR
Notch for487C2Clips
Notch for487C2Clips
487x218
487x217
487x217
Notch for 487C2 Clips
For units that require single pane glazing, use 487x217 and 487x218 Fillers at interior horizontal and vertical glazing pockets. Follow instructions in this manual to install the frame. Then install fillers and clips at interior as shown. Continue with glazing the exterior panels.
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM25crlaurence.com | usalum.com
SINGLE PANE GLAZING INSTALLATION
Install Filler at Interior Header and Sill
Install Filler at Interior Jambs and Intermediate Verticals
2
1
NOTE: Horizontal Fillers fit between Vertical Fillers.
NOTE: Adjust screw spacing to avoid Clips. See placement chart below.
NOTE: Refer to Page 8 for exterior clip placement
Install 487x218 Fillers at interior 487x203 Intermediate Horizontals. Space 20061601 Screws 2” (51 mm) from ends and 12” (305 mm) on center.
Install 487C1 and 487C2 Clips with 20061601 Screws at interior locations shown below.
Continue installation with exterior clips and then glaze interior panels according to instructions in this manual.
487x203Intermediate Vertical 20061601
487x218
EXTERIOR
1
1
487x218
200616101
INTERIOR
Interior Clip Placement for Single Pane Glazing
Sidelite
Sidelite
Fixed Lite
Fixed Lite
Doorway
487x216
487x200
487x
200
487x
201
487x
201
487x
208
487x202
487x201
487x201
487x203
487x217
487x217
487x218
487x202
487x201
487x201
487x203
487x217
487x217
487x218
487x
203
487x
218
487x
217
487x
217
487x
201
487x
201
487x
208
487x
203
487x
218
487x
217
487x
217
487C1
487C1
487C1
487C1
487C2
487C2
487C2
487C2
487C2
487C
2
487C
2
Notch Vertical Filler for 487C2 Clips
Notch Vertical Filler for 487C2 Clips
Notch Vertical Filler for 487C2 Clips
Notch Vertical Filler for 487C2 Clips
SERIES 487 ACOUSTIC RATED DOUBLE GLAZED OFFICE PARTITIONS
ALUMINUM26crlaurence.com | usalum.com
SINGLE PANE GLAZING INSTALLATION (CONTINUED)Install Filler at Interior Intermediate Horizontals
Interior Clip Placement
Install Interior Clips