INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and...
Transcript of INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and...
93041643
ACRD - ABL
6/20/2012
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
6/20/201216555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
(REMOTE BALLAST)
WIRE LEADSINCOMING
WIRECONNECTIONS(BY OTHERS)
LAMP COMPARTMENT
INSPECTION COVER(2)S/S SET SCREWS
FIXTURE ASSEMBLY
ARM ASSEMBLY
S/S CAP SCREW
LAMP (BY OTHERS)
4" O.D. POLE (REF)
FRONT OF FIXTURE
FIXTURE ASS'Y.SUSPENDED FROM ARM (ABL) (BALLAST ASS'Y. LOCATED REMOTE)
STUDS
ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE
4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING
3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY FROM REMOTE BALLAST. (WHITE TO WHITE, BLACK TO BLACK, GREEN TO GREEN). NOTE: CONNECT GREEN GROUND LEAD TO EQUIPMENT GROUND.
LAMP INSTALLATION STEPS:
4) INSTALLATION COMPLETE.3) CLOSE FIXTURE AND SECURE CAP SCREW.
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.
FIXTURE INSTALLATION STEPS:
AND BALLAST INTO ARM ASSEMBLY.
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
2) INSTALL LAMP.1) TURN POWER OFF.
6) INSTALLATION COMPLETE.
REMOTE BALLAST:
1) BALLAST ASS'Y. BY A.A.L. TO BE LOCATED REMOTE. REMOTE COMPARTMENT AND INSTALLATION BY OTHERS.
POLE TOP OPEN (REF.)
A96379
ACSQ - WMBL
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
INCOMING WIRE LEADS
MOUNTING PLATE
JUNCTION BOX(BY OTHERS)
STUDS(BY OTHERS)
FIXTURE ASSEMBLY
ARM ASSEMBLY
WIRE CONNECTIONS
2) INSTALL LAMP.2) INSTALL LAMP.
MOUNTING PLATE(ORIENTATION)
FIXTUREFRONT OF
7) INSTALLATION COMPLETE.
INSTALLATION STEPS:
1) TURN POWER OFF.
HARDWARE BY OTHERS)
AND BALLAST INTO ARM ASSEMBLY.
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
LAMP INSTALLATION STEPS:
INSPECTION COVER
6) SILICONE ALL AROUND BACK PLATE MOUNTING SURFACE, AS SHOWN.
3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.
ARM ASS'Y TO MOUNTING SURFACE. (NOT FOR J-BOX MOUNTING
(2)S/S SET SCREWS
S/S CAP SCREW
LAMP COMPARTMENT
LAMP (BY OTHERS)
4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING
WALL MOUNTED SUSPENDED FROM ARM (WMBL)
SILICONE
4.50
6.00
.281
5.44
12.50
6.19
14.00
(4) O 1/2" THRU HOLES
A96380
ACSQ - WMTP
7/22/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
FIXTURE ASS'Y.
LAMP (BY OTHERS)
LAMP COMPARTMENT
(4) S/S SET SCREWS
S/S CAP SCREW
KNOB
SOCKET ASSEMBLY
(ORIENTATION)
MOUNTING PLATE
MOUNTING PLATEFRONT OFFIXTURE
WIRE CONNECTIONS
(BY OTHERS)JUNCTION BOX
INCOMING WIRE LEADS
SECURE.
7) INSTALLATION COMPLETE.
1) TURN POWER OFF.
FIXTURE INSTALLATION STEPS:
INSPECTION COVER
FROM FIXTUREWIRE LEADS
SILICONE
WITH (4) SET SCREWS.
(BY OTHERS)(2) S/S SET SCREWS
4) INSTALLATION COMPLETE.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO
LAMP INSTALLATION STEPS:
3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
ARM ASS'Y TO MOUNTING SURFACE . (NOT FOR J-BOX MOUNTING.2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE
MOUNTING HARDWARE BY OTHERS).
ACCESS TO LAMP COMPARTMENT. KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW
WALL MOUNTED TOP OF ARM (WMTP)
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST
MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.
6) SILICONE ALL AROUND BACK PLATE AND MOUNTING SURFACE AS SHOWN.
4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND MAKE WIRE
6.19
14.00 12.50
5.44
2.31
4.50
6.00
(4) O 1/2"THRU HOLES
A96381
ACSQ - ABL
7/26/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
HARDWARE BY OTHERS)
6) INSTALLATION COMPLETE.
1) TURN POWER OFF.
2) INSTALL LAMP.
LAMP (BY OTHERS)
S/S CAP SCREW
(REF)
FRONT OF FIXTURE
FIXTURE ASSEMBLY
(2)S/S SET SCREWSINSPECTION COVER
ARM ASSEMBLY
4" SQ. POLE
(BY OTHERS)CONNECTIONSWIRE
PLATEADAPTERA500055-1
WIRE LEADSINCOMING
4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING
ARM ASS'Y TO MOUNTING SURFACE. (NOT FOR J-BOX MOUNTING
3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.
2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE
STUDS
SUSPENDED FROM ARM (ABL)
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
AND BALLAST INTO ARM ASSEMBLY.
FIXTURE INSTALLATION STEPS:
LAMP INSTALLATION STEPS:
4) INSTALLATION COMPLETE.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.
LAMP COMPARTMENT
A96382
ACSQ - PND
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
TO FIXTURE(BY OTHERS)
JUNCTION BOX(BY OTHERS)
WIRECONNECTIONS
CANOPY
STEM ASS'Y.
WIRE LEADS
MOUNTING PLATE(ORIENTATION)
LAMP(BY OTHERS)
2) INSTALL LAMP.
4) INSTALLATION COMPLETE.
LAMP INSTALLATION STEPS:
1) TURN OFF ALL POWER.
FIXTURE INSTALLATION STEPS:
2) RUN WIRE LEADS AND SAFETY CABLE FROM
FIXTURE THROUGH STEM ASSEMBLY. SECURE THE THREADED
END OF THE STEM TO THE LAMP COMPARTMENT.
AS SHOWN. SECURE MOUNTING PLATE TO CEILING. MAKE SURE
MOUNTING IS INDEPENDENT OF J-BOX. (MEANS OF MOUNTING
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
3) PASS INCOMING WIRE LEADS FROM J-BOX THROUGH WIRE WAY,
4) SLIP CANOPY OVER STEM ASSEMBLY. HANG STEM TO THE
MOUNTING BRACKET. MAKE ALL WIRE CONNECTIONS.
AND MOUNTING HARDWARE BY OTHERS).
SAFETY CABLE MUST BESECURED TO SUPER
STRUCTURE OF BUILDING.
(BY OTHERS)
(BY OTHERS)
(BY OTHERS)
6) INSTALLATION COMPLETE.
FROM FIXTURE
5) SLIDE CANOPY UP. TURN TO LOCK IT INTO THE MOUNTING BRACKET.
S/S CAP SCREW
LAMPCOMPARTMENT
FRONT OF FIXTURE
MOUNTING PLATE
INCOMING WIRE LEADS
NOTE: TO BE MOUNTEDINDEPENDANT
OF J-BOX
INCOMING WIRECONNECTIONS
PENDANT WITH STEM MOUNTING (PND)
3.19
1.59
2.76
5.52
O 2.06
(3) O 1/4"CLEAR
WIREWAY
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
A96383
ACSQ - ATP
7/26/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
S/S CAP SCREW
(4) S/S SET SCREWS
A500055-1ADAPTOR PLATE
SOCKET ASSEMBLY
KNOB
LAMP COMPARTMENT
LAMP (BY OTHERS)
FIXTURE ASS'Y.
INCOMING WIRE LEADS
WIRE CONNECTIONS(BY OTHERS)
WIRE LEADS
FIXTUREFRONT OF
SECURE.
WITH (4) S/S SET SCREWS.
6) INSTALLATION COMPLETE.
FIXTURE INSTALLATION STEPS:
1) TURN POWER OFF.
INSPECTION COVER(2) S/S SET SCREWS
4" SQ. POLE (REF.)
4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE
2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE
2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW ACCESS TO LAMP COMPARTMENT.
LAMP INSTALLATION STEPS:
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST
POST TOP ARM MOUNTING (ATP)
ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.
MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.
FROM FIXTURE
A96384
ACSQ - PT
7/26/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
SECURE.
FRONT OF FIXTURE
FIXTURE INSTALLATION STEPS:
1) TURN POWER OFF.
4) INSTALLATION COMPLETE.
WIRE CONNECTIONS(BY OTHERS)
SOCKET ASSEMBLY
KNOB
S/S CAP SCREW
LAMP COMPARTMENT
LAMP (BY OTHERS)
FIXTURE ASS'Y.
3) SLIP FIXTURE OVER POLE. ALIGN AND SECURE FIXTURE
2) MAKE WIRE CONNECTION FROM FIXTURE TO POLE.
TO POLE WITH (4) S/S SET SCREWS.
2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
ACCESS TO LAMP COMPARTMENT.
4" SQ. POLE(REF.)
(4) S/S SET SCREWS
INCOMING WIRE LEADS
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST
LAMP INSTALLATION STEPS:
KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW
POST TOP MOUNTING (PT)
A96385
ACRD-WMBL
7/26/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
MOUNTING PLATE
INCOMING WIRE LEADS
JUNCTION BOX(BY OTHERS)
STUDSWIRE CONNECTIONS(BY OTHERS)
FIXTURE ASSEMBLY
ARM ASSEMBLY
2) INSTALL LAMP.2) INSTALL LAMP.
MOUNTING PLATE(ORIENTATION)
FIXTURE
7) INSTALLATION COMPLETE.
INSTALLATION STEPS:
1) TURN POWER OFF.
HARDWARE BY OTHERS)
FRONT OF
AND BALLAST INTO ARM ASSEMBLY.
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
LAMP INSTALLATION STEPS:
INSPECTION COVER
6) SILICONE ALL AROUND BACK PLATE MOUNTING SURFACE, AS SHOWN.
2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE
3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.
ARM ASS'Y TO MOUNTING SURFACE. (NOT FOR J-BOX MOUNTING
(2)S/S SET SCREWS
S/S CAP SCREW
LAMP COMPARTMENT
LAMP (BY OTHERS)
4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING
WALL MOUNTED SUSPENDED FROM ARM (WMBL)
MOUNTING PLATE
SILICONE
5.44
12.50
6.19
14.00
2.25
4.50
6.00
(4) O 1/2"THRU HOLE
A96386
ACRD - WMTP
7/27/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
MOUNTING PLATE(ORIENTATION)
KNOB
FIXTUREFRONT OF
SECURE.
SILICONE
WITH (4) S/S SET SCREWS.
7) INSTALLATION COMPLETE.
FIXTURE INSTALLATION STEPS:
1) TURN POWER OFF.
INSPECTION COVER
WIRE LEADSFROM FIXTURE
MOUNTING PLATE
(2) S/S SET SCREWS
2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW ACCESS TO LAMP COMPARTMENT.
INCOMING WIRE LEADS
JUNCTION BOX(BY OTHERS)
WIRE CONNECTIONS(BY OTHERS)
LAMP INSTALLATION STEPS:
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE ARM ASS'Y TO MOUNTING SURFACE . (NOT FOR J-BOX MOUNTING. MOUNTING HARDWARE BY OTHERS).
WALL MOUNTED TOP OF ARM (WMTP)
LAMP COMPARTMENT
LAMP (BY OTHERS)
SOCKET ASSEMBLY
S/S CAP SCREW
(4) S/S SET SCREWS
FIXTURE ASS'Y.
3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST
4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND MAKE WIRE
6) SILICONE ALL AROUND BACK PLATE AND MOUNTING SURFACE AS SHOWN.
MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.
2.25
4.50
6.00
6.19
14.00
5.44
12.50
(4) O 1/2"THRU HOLE
A96387
ACRD - PND
7/26/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
JUNCTION BOX(BY OTHERS)
WIRECONNECTIONSTO FIXTURE(BY OTHERS)
CANOPY
STEM ASS'Y.
WIRE LEADS
MOUNTING PLATE(ORIENTATION)
LAMP(BY OTHERS)
2) INSTALL LAMP.
4) INSTALLATION COMPLETE.
LAMP INSTALLATION STEPS:
1) TURN OFF ALL POWER.
FIXTURE INSTALLATION STEPS:
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
3) PASS INCOMING WIRE LEADS FROM J-BOX THROUGH WIRE WAY,
4) SLIP CANOPY OVER STEM ASSEMBLY. HANG STEM TO THE
MOUNTING BRACKET. MAKE ALL WIRE CONNECTIONS.
AND MOUNTING HARDWARE BY OTHERS).
2) RUN WIRE LEADS AND SAFETY CABLE FROM
FIXTURE THROUGH STEM ASSEMBLY. SECURE THE THREADED
END OF THE STEM TO THE LAMP COMPARTMENT.
AS SHOWN. SECURE MOUNTING PLATE TO CEILING. MAKE SURE
MOUNTING IS INDEPENDENT OF J-BOX. (MEANS OF MOUNTING
OF J-BOX
INCOMING WIRECONNECTIONS
SAFETY CABLE MUST BESECURED TO SUPER
STRUCTURE OF BUILDING.
(BY OTHERS)
(BY OTHERS)
(BY OTHERS)
6) INSTALLATION COMPLETE.
FROM FIXTURE
5) SLIDE CANOPY UP. TURN TO LOCK IT INTO THE MOUNTING BRACKET.
S/S CAP SCREW
LAMPCOMPARTMENT
FRONT OF FIXTURE
PENDANT WITH STEM MOUNTING (PND)
MOUNTING PLATE
INCOMING WIRE LEADS
NOTE: TO BE MOUNTEDINDEPENDANT
1.59
3.19
2.76
5.52
O 2.06WIREWAY
(3) O 1/4" MTG. HOLES
A96388
ACRD - ABL
7/22/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
WIRE LEADSINCOMING
WIRECONNECTIONS(BY OTHERS)
LAMP COMPARTMENT
INSPECTION COVER(2)S/S SET SCREWS
FIXTURE ASSEMBLY
ARM ASSEMBLY
6) INSTALLATION COMPLETE.
1) TURN POWER OFF.
2) INSTALL LAMP.
S/S CAP SCREW
LAMP (BY OTHERS)
4" O.D. POLE (REF)
FRONT OF FIXTURE
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
AND BALLAST INTO ARM ASSEMBLY.
FIXTURE INSTALLATION STEPS:
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
LAMP INSTALLATION STEPS:3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.
4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING
2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.
SUSPENDED FROM ARM (ABL)
STUDS
A96389
ACRD - ATP
7/26/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
LAMP (BY OTHERS)
FIXTURE ASS'Y.
S/S CAP SCREW
(4) S/S SET SCREWS
SOCKET ASSEMBLY
KNOB
LAMP COMPARTMENT
INCOMING WIRE LEADS
WIRE CONNECTIONS(BY OTHERS)
WIRE LEADS
FIXTUREFRONT OF
SECURE.
WITH (4) S/S SET SCREWS.
6) INSTALLATION COMPLETE.
FIXTURE INSTALLATION STEPS:
1) TURN POWER OFF.
INSPECTION COVER(2) S/S SET SCREWS
4" O.D. POLE (REF.)
4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND
5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.
3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE
2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE
2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL
3) CLOSE FIXTURE AND SECURE CAP SCREW.
4) INSTALLATION COMPLETE.
KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW ACCESS TO LAMP COMPARTMENT.
LAMP INSTALLATION STEPS:
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST
MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.
ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.
POST TOP ARM MOUNTING (ATP)
FROM FIXTURE
A96390
ACRD - PT
7/26/2010
INSTALLATION INSTRUCTIONSCATALOG NUMBER
PART NO.APPRVDDATE
DATE REV.
16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666
1) TURN POWER OFF.
4) INSTALLATION COMPLETE.
WIRE CONNECTIONS(BY OTHERS)
LAMP COMPARTMENT.
5) INSTALLATION COMPLETE.
LAMP INSTALLATION STEPS:
FRONT OF FIXTURE
SOCKET ASSEMBLY
KNOB
S/S CAP SCREW
LAMP COMPARTMENT
LAMP (BY OTHERS)
FIXTURE ASS'Y
FIXTURE INSTALLATION STEPS:
3) SLIP FIXTURE OVER POLE. ALIGN AND SECURE FIXTURE
2) MAKE WIRE CONNECTION FROM FIXTURE TO POLE.
TO POLE WITH (4) S/S SET SCREWS.
2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO
4) CLOSE FIXTURE AND SECURE CAP SCREW.
3) PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT AND TURN KNOB CLOCKWISE UNTIL SECURE.
POLE 4" O.D.(REF.)
(4) S/S SET SCREWS
INCOMING WIRE LEADS
1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TURN KNOB COUNTER-CLOCKWISE AND PULL TO ALLOW ACCESS TO LAMP COMPARTMENT.
POST TOP MOUNTING (PT)