INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and...

13
93041643 ACRD - ABL 6/20/2012 INSTALLATION INSTRUCTIONS CATALOG NUMBER PART NO. APPRVD DATE DATE REV. 6/20/2012 16555 East Gale Avenue City of Industry, CA 91745 (626)968-5666 (REMOTE BALLAST) WIRE LEADS INCOMING WIRE CONNECTIONS (BY OTHERS) LAMP COMPARTMENT INSPECTION COVER (2)S/S SET SCREWS FIXTURE ASSEMBLY ARM ASSEMBLY S/S CAP SCREW LAMP (BY OTHERS) 4" O.D. POLE (REF) FRONT OF FIXTURE FI X TUR E A S S 'Y . S U S P E ND E D FR OM AR M (ABL) (BALLAST ASS'Y. LOCATED REMOTE) STUDS ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS. 2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE 4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING 3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY FROM REMOTE BALLAST. (WHITE TO WHITE, BLACK TO BLACK, GREEN TO GREEN). NOTE: CONNECT GREEN GROUND LEAD TO EQUIPMENT GROUND. L A MP INST A L L A TIO N STEP S: 4) INSTALLATION COMPLETE. 3) CLOSE FIXTURE AND SECURE CAP SCREW. 1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. FIXTU RE INST A L L A TIO N STEP S: AND BALLAST INTO ARM ASSEMBLY. 5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS. 2) INSTALL LAMP. 1) TURN POWER OFF. 6) INSTALLATION COMPLETE. RE M OTE B A LL AS T : 1) BALLAST ASS'Y. BY A.A.L. TO BE LOCATED REMOTE. REMOTE COMPARTMENT AND INSTALLATION BY OTHERS. POLE TOP OPEN (REF.)

Transcript of INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and...

Page 1: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

93041643

ACRD - ABL

6/20/2012

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

6/20/201216555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

(REMOTE BALLAST)

WIRE LEADSINCOMING

WIRECONNECTIONS(BY OTHERS)

LAMP COMPARTMENT

INSPECTION COVER(2)S/S SET SCREWS

FIXTURE ASSEMBLY

ARM ASSEMBLY

S/S CAP SCREW

LAMP (BY OTHERS)

4" O.D. POLE (REF)

FRONT OF FIXTURE

FIXTURE ASS'Y.SUSPENDED FROM ARM (ABL) (BALLAST ASS'Y. LOCATED REMOTE)

STUDS

ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE

4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING

3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY FROM REMOTE BALLAST. (WHITE TO WHITE, BLACK TO BLACK, GREEN TO GREEN). NOTE: CONNECT GREEN GROUND LEAD TO EQUIPMENT GROUND.

LAMP INSTALLATION STEPS:

4) INSTALLATION COMPLETE.3) CLOSE FIXTURE AND SECURE CAP SCREW.

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.

FIXTURE INSTALLATION STEPS:

AND BALLAST INTO ARM ASSEMBLY.

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

2) INSTALL LAMP.1) TURN POWER OFF.

6) INSTALLATION COMPLETE.

REMOTE BALLAST:

1) BALLAST ASS'Y. BY A.A.L. TO BE LOCATED REMOTE. REMOTE COMPARTMENT AND INSTALLATION BY OTHERS.

POLE TOP OPEN (REF.)

Page 2: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96379

ACSQ - WMBL

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

INCOMING WIRE LEADS

MOUNTING PLATE

JUNCTION BOX(BY OTHERS)

STUDS(BY OTHERS)

FIXTURE ASSEMBLY

ARM ASSEMBLY

WIRE CONNECTIONS

2) INSTALL LAMP.2) INSTALL LAMP.

MOUNTING PLATE(ORIENTATION)

FIXTUREFRONT OF

7) INSTALLATION COMPLETE.

INSTALLATION STEPS:

1) TURN POWER OFF.

HARDWARE BY OTHERS)

AND BALLAST INTO ARM ASSEMBLY.

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

LAMP INSTALLATION STEPS:

INSPECTION COVER

6) SILICONE ALL AROUND BACK PLATE MOUNTING SURFACE, AS SHOWN.

3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.

ARM ASS'Y TO MOUNTING SURFACE. (NOT FOR J-BOX MOUNTING

(2)S/S SET SCREWS

S/S CAP SCREW

LAMP COMPARTMENT

LAMP (BY OTHERS)

4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING

WALL MOUNTED SUSPENDED FROM ARM (WMBL)

SILICONE

4.50

6.00

.281

5.44

12.50

6.19

14.00

(4) O 1/2" THRU HOLES

Page 3: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96380

ACSQ - WMTP

7/22/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

FIXTURE ASS'Y.

LAMP (BY OTHERS)

LAMP COMPARTMENT

(4) S/S SET SCREWS

S/S CAP SCREW

KNOB

SOCKET ASSEMBLY

(ORIENTATION)

MOUNTING PLATE

MOUNTING PLATEFRONT OFFIXTURE

WIRE CONNECTIONS

(BY OTHERS)JUNCTION BOX

INCOMING WIRE LEADS

SECURE.

7) INSTALLATION COMPLETE.

1) TURN POWER OFF.

FIXTURE INSTALLATION STEPS:

INSPECTION COVER

FROM FIXTUREWIRE LEADS

SILICONE

WITH (4) SET SCREWS.

(BY OTHERS)(2) S/S SET SCREWS

4) INSTALLATION COMPLETE.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO

LAMP INSTALLATION STEPS:

3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

ARM ASS'Y TO MOUNTING SURFACE . (NOT FOR J-BOX MOUNTING.2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE

MOUNTING HARDWARE BY OTHERS).

ACCESS TO LAMP COMPARTMENT. KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW

WALL MOUNTED TOP OF ARM (WMTP)

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST

MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.

6) SILICONE ALL AROUND BACK PLATE AND MOUNTING SURFACE AS SHOWN.

4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND MAKE WIRE

6.19

14.00 12.50

5.44

2.31

4.50

6.00

(4) O 1/2"THRU HOLES

Page 4: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96381

ACSQ - ABL

7/26/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

HARDWARE BY OTHERS)

6) INSTALLATION COMPLETE.

1) TURN POWER OFF.

2) INSTALL LAMP.

LAMP (BY OTHERS)

S/S CAP SCREW

(REF)

FRONT OF FIXTURE

FIXTURE ASSEMBLY

(2)S/S SET SCREWSINSPECTION COVER

ARM ASSEMBLY

4" SQ. POLE

(BY OTHERS)CONNECTIONSWIRE

PLATEADAPTERA500055-1

WIRE LEADSINCOMING

4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING

ARM ASS'Y TO MOUNTING SURFACE. (NOT FOR J-BOX MOUNTING

3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.

2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE

STUDS

SUSPENDED FROM ARM (ABL)

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

AND BALLAST INTO ARM ASSEMBLY.

FIXTURE INSTALLATION STEPS:

LAMP INSTALLATION STEPS:

4) INSTALLATION COMPLETE.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.

LAMP COMPARTMENT

Page 5: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96382

ACSQ - PND

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

TO FIXTURE(BY OTHERS)

JUNCTION BOX(BY OTHERS)

WIRECONNECTIONS

CANOPY

STEM ASS'Y.

WIRE LEADS

MOUNTING PLATE(ORIENTATION)

LAMP(BY OTHERS)

2) INSTALL LAMP.

4) INSTALLATION COMPLETE.

LAMP INSTALLATION STEPS:

1) TURN OFF ALL POWER.

FIXTURE INSTALLATION STEPS:

2) RUN WIRE LEADS AND SAFETY CABLE FROM

FIXTURE THROUGH STEM ASSEMBLY. SECURE THE THREADED

END OF THE STEM TO THE LAMP COMPARTMENT.

AS SHOWN. SECURE MOUNTING PLATE TO CEILING. MAKE SURE

MOUNTING IS INDEPENDENT OF J-BOX. (MEANS OF MOUNTING

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

3) PASS INCOMING WIRE LEADS FROM J-BOX THROUGH WIRE WAY,

4) SLIP CANOPY OVER STEM ASSEMBLY. HANG STEM TO THE

MOUNTING BRACKET. MAKE ALL WIRE CONNECTIONS.

AND MOUNTING HARDWARE BY OTHERS).

SAFETY CABLE MUST BESECURED TO SUPER

STRUCTURE OF BUILDING.

(BY OTHERS)

(BY OTHERS)

(BY OTHERS)

6) INSTALLATION COMPLETE.

FROM FIXTURE

5) SLIDE CANOPY UP. TURN TO LOCK IT INTO THE MOUNTING BRACKET.

S/S CAP SCREW

LAMPCOMPARTMENT

FRONT OF FIXTURE

MOUNTING PLATE

INCOMING WIRE LEADS

NOTE: TO BE MOUNTEDINDEPENDANT

OF J-BOX

INCOMING WIRECONNECTIONS

PENDANT WITH STEM MOUNTING (PND)

3.19

1.59

2.76

5.52

O 2.06

(3) O 1/4"CLEAR

WIREWAY

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

Page 6: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96383

ACSQ - ATP

7/26/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

S/S CAP SCREW

(4) S/S SET SCREWS

A500055-1ADAPTOR PLATE

SOCKET ASSEMBLY

KNOB

LAMP COMPARTMENT

LAMP (BY OTHERS)

FIXTURE ASS'Y.

INCOMING WIRE LEADS

WIRE CONNECTIONS(BY OTHERS)

WIRE LEADS

FIXTUREFRONT OF

SECURE.

WITH (4) S/S SET SCREWS.

6) INSTALLATION COMPLETE.

FIXTURE INSTALLATION STEPS:

1) TURN POWER OFF.

INSPECTION COVER(2) S/S SET SCREWS

4" SQ. POLE (REF.)

4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE

2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE

2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW ACCESS TO LAMP COMPARTMENT.

LAMP INSTALLATION STEPS:

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST

POST TOP ARM MOUNTING (ATP)

ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.

MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.

FROM FIXTURE

Page 7: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96384

ACSQ - PT

7/26/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

SECURE.

FRONT OF FIXTURE

FIXTURE INSTALLATION STEPS:

1) TURN POWER OFF.

4) INSTALLATION COMPLETE.

WIRE CONNECTIONS(BY OTHERS)

SOCKET ASSEMBLY

KNOB

S/S CAP SCREW

LAMP COMPARTMENT

LAMP (BY OTHERS)

FIXTURE ASS'Y.

3) SLIP FIXTURE OVER POLE. ALIGN AND SECURE FIXTURE

2) MAKE WIRE CONNECTION FROM FIXTURE TO POLE.

TO POLE WITH (4) S/S SET SCREWS.

2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

ACCESS TO LAMP COMPARTMENT.

4" SQ. POLE(REF.)

(4) S/S SET SCREWS

INCOMING WIRE LEADS

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST

LAMP INSTALLATION STEPS:

KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW

POST TOP MOUNTING (PT)

Page 8: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96385

ACRD-WMBL

7/26/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

MOUNTING PLATE

INCOMING WIRE LEADS

JUNCTION BOX(BY OTHERS)

STUDSWIRE CONNECTIONS(BY OTHERS)

FIXTURE ASSEMBLY

ARM ASSEMBLY

2) INSTALL LAMP.2) INSTALL LAMP.

MOUNTING PLATE(ORIENTATION)

FIXTURE

7) INSTALLATION COMPLETE.

INSTALLATION STEPS:

1) TURN POWER OFF.

HARDWARE BY OTHERS)

FRONT OF

AND BALLAST INTO ARM ASSEMBLY.

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TO ALLOW ACCESS LAMP COMPARTMENT.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

LAMP INSTALLATION STEPS:

INSPECTION COVER

6) SILICONE ALL AROUND BACK PLATE MOUNTING SURFACE, AS SHOWN.

2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE

3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.

ARM ASS'Y TO MOUNTING SURFACE. (NOT FOR J-BOX MOUNTING

(2)S/S SET SCREWS

S/S CAP SCREW

LAMP COMPARTMENT

LAMP (BY OTHERS)

4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING

WALL MOUNTED SUSPENDED FROM ARM (WMBL)

MOUNTING PLATE

SILICONE

5.44

12.50

6.19

14.00

2.25

4.50

6.00

(4) O 1/2"THRU HOLE

Page 9: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96386

ACRD - WMTP

7/27/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

MOUNTING PLATE(ORIENTATION)

KNOB

FIXTUREFRONT OF

SECURE.

SILICONE

WITH (4) S/S SET SCREWS.

7) INSTALLATION COMPLETE.

FIXTURE INSTALLATION STEPS:

1) TURN POWER OFF.

INSPECTION COVER

WIRE LEADSFROM FIXTURE

MOUNTING PLATE

(2) S/S SET SCREWS

2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW ACCESS TO LAMP COMPARTMENT.

INCOMING WIRE LEADS

JUNCTION BOX(BY OTHERS)

WIRE CONNECTIONS(BY OTHERS)

LAMP INSTALLATION STEPS:

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE ARM ASS'Y TO MOUNTING SURFACE . (NOT FOR J-BOX MOUNTING. MOUNTING HARDWARE BY OTHERS).

WALL MOUNTED TOP OF ARM (WMTP)

LAMP COMPARTMENT

LAMP (BY OTHERS)

SOCKET ASSEMBLY

S/S CAP SCREW

(4) S/S SET SCREWS

FIXTURE ASS'Y.

3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST

4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND MAKE WIRE

6) SILICONE ALL AROUND BACK PLATE AND MOUNTING SURFACE AS SHOWN.

MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.

2.25

4.50

6.00

6.19

14.00

5.44

12.50

(4) O 1/2"THRU HOLE

Page 10: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96387

ACRD - PND

7/26/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

JUNCTION BOX(BY OTHERS)

WIRECONNECTIONSTO FIXTURE(BY OTHERS)

CANOPY

STEM ASS'Y.

WIRE LEADS

MOUNTING PLATE(ORIENTATION)

LAMP(BY OTHERS)

2) INSTALL LAMP.

4) INSTALLATION COMPLETE.

LAMP INSTALLATION STEPS:

1) TURN OFF ALL POWER.

FIXTURE INSTALLATION STEPS:

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

3) PASS INCOMING WIRE LEADS FROM J-BOX THROUGH WIRE WAY,

4) SLIP CANOPY OVER STEM ASSEMBLY. HANG STEM TO THE

MOUNTING BRACKET. MAKE ALL WIRE CONNECTIONS.

AND MOUNTING HARDWARE BY OTHERS).

2) RUN WIRE LEADS AND SAFETY CABLE FROM

FIXTURE THROUGH STEM ASSEMBLY. SECURE THE THREADED

END OF THE STEM TO THE LAMP COMPARTMENT.

AS SHOWN. SECURE MOUNTING PLATE TO CEILING. MAKE SURE

MOUNTING IS INDEPENDENT OF J-BOX. (MEANS OF MOUNTING

OF J-BOX

INCOMING WIRECONNECTIONS

SAFETY CABLE MUST BESECURED TO SUPER

STRUCTURE OF BUILDING.

(BY OTHERS)

(BY OTHERS)

(BY OTHERS)

6) INSTALLATION COMPLETE.

FROM FIXTURE

5) SLIDE CANOPY UP. TURN TO LOCK IT INTO THE MOUNTING BRACKET.

S/S CAP SCREW

LAMPCOMPARTMENT

FRONT OF FIXTURE

PENDANT WITH STEM MOUNTING (PND)

MOUNTING PLATE

INCOMING WIRE LEADS

NOTE: TO BE MOUNTEDINDEPENDANT

1.59

3.19

2.76

5.52

O 2.06WIREWAY

(3) O 1/4" MTG. HOLES

Page 11: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96388

ACRD - ABL

7/22/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

WIRE LEADSINCOMING

WIRECONNECTIONS(BY OTHERS)

LAMP COMPARTMENT

INSPECTION COVER(2)S/S SET SCREWS

FIXTURE ASSEMBLY

ARM ASSEMBLY

6) INSTALLATION COMPLETE.

1) TURN POWER OFF.

2) INSTALL LAMP.

S/S CAP SCREW

LAMP (BY OTHERS)

4" O.D. POLE (REF)

FRONT OF FIXTURE

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

AND BALLAST INTO ARM ASSEMBLY.

FIXTURE INSTALLATION STEPS:

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE.

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

LAMP INSTALLATION STEPS:3) MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO BALLAST.

4) ALIGN STUDS WITH TOP OF BALLAST BRACKET AND PLACE ALL WIRING

2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.

SUSPENDED FROM ARM (ABL)

STUDS

Page 12: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96389

ACRD - ATP

7/26/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

LAMP (BY OTHERS)

FIXTURE ASS'Y.

S/S CAP SCREW

(4) S/S SET SCREWS

SOCKET ASSEMBLY

KNOB

LAMP COMPARTMENT

INCOMING WIRE LEADS

WIRE CONNECTIONS(BY OTHERS)

WIRE LEADS

FIXTUREFRONT OF

SECURE.

WITH (4) S/S SET SCREWS.

6) INSTALLATION COMPLETE.

FIXTURE INSTALLATION STEPS:

1) TURN POWER OFF.

INSPECTION COVER(2) S/S SET SCREWS

4" O.D. POLE (REF.)

4) PULL WIRE LEADS FROM FIXTURE THROUGH ARM ASS'Y AND

5) SECURE INSPECTION COVER WITH (2) S/S SET SCREWS.

3) PLACE FIXTURE ASS'Y. ONTO ARM ASS'Y AS SHOWN AND SECURE

2) PULL INCOMING WIRE LEADS THROUGH WIRE WAY AND SECURE

2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT, TWIST KNOB CLOCKWISE UNTIL

3) CLOSE FIXTURE AND SECURE CAP SCREW.

4) INSTALLATION COMPLETE.

KNOB COUNTER CLOCKWISE AND LIFT OUT TO ALLOW ACCESS TO LAMP COMPARTMENT.

LAMP INSTALLATION STEPS:

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TWIST

MAKE WIRE CONNECTIONS FROM INCOMING SUPPLY TO FIXTURE ASS'Y.

ARM ASS'Y TO POLE WITH (2) 3/8-16 HEX BOLTS AND LOCK WASHERS.

POST TOP ARM MOUNTING (ATP)

FROM FIXTURE

Page 13: INSTALLATION INSTRUCTIONS (REMOTE BALLAST)fixtu re inst allatio n step s: 2) run wire leads and safety cable from fixture through stem assembly. secure the threaded end of the stem

A96390

ACRD - PT

7/26/2010

INSTALLATION INSTRUCTIONSCATALOG NUMBER

PART NO.APPRVDDATE

DATE REV.

16555 East Gale AvenueCity of Industry, CA 91745(626)968-5666

1) TURN POWER OFF.

4) INSTALLATION COMPLETE.

WIRE CONNECTIONS(BY OTHERS)

LAMP COMPARTMENT.

5) INSTALLATION COMPLETE.

LAMP INSTALLATION STEPS:

FRONT OF FIXTURE

SOCKET ASSEMBLY

KNOB

S/S CAP SCREW

LAMP COMPARTMENT

LAMP (BY OTHERS)

FIXTURE ASS'Y

FIXTURE INSTALLATION STEPS:

3) SLIP FIXTURE OVER POLE. ALIGN AND SECURE FIXTURE

2) MAKE WIRE CONNECTION FROM FIXTURE TO POLE.

TO POLE WITH (4) S/S SET SCREWS.

2) INSTALL LAMP AND PLACE SOCKET ASSEMBLY BACK INTO

4) CLOSE FIXTURE AND SECURE CAP SCREW.

3) PLACE SOCKET ASSEMBLY BACK INTO LAMP COMPARTMENT AND TURN KNOB CLOCKWISE UNTIL SECURE.

POLE 4" O.D.(REF.)

(4) S/S SET SCREWS

INCOMING WIRE LEADS

1) LOOSEN S/S CAP SCREW AND OPEN FIXTURE. TURN KNOB COUNTER-CLOCKWISE AND PULL TO ALLOW ACCESS TO LAMP COMPARTMENT.

POST TOP MOUNTING (PT)