Install NI LabVIEW™ and Add-on Requirements STEP 1 Installation Guide: Quanser Rapid Control Prototyping Toolkit ® 2016 for NI myRIO ® Install Quanser Rapid Control Prototyping Toolkit on Windows STEP 2 A Uninstall any previous version of the Quanser Rapid Control Prototyping (QRCP) toolkit that may be present on the computer (e.g., QRCP 2012). Do so by launching the Programs and Features dialog from the Windows Control Panel. Ensure that at least one version of 32-bit LabVIEW™ 2015 SP1 or 2016 is installed on the host computer with the following required add-ons: 1. LabVIEW™ NI myRIO Module 2. LabVIEW™ Control Design and Simulation Module 3. From the NI Device Drivers DVD: (a) Reconfigurable I/O (RIO) Feature (b) Real-Time and Embedded Feature 4. LabVIEW™ Real-Time Module 5. LabVIEW™ MathScript RT Module (only used in certain curriculum VIs) The Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1, or Windows 10 for the host system and select NI myRIO configurations as targets. B 1. Insert the QRCP 2016 Installation DVD. If you purchased your QRCP through LABVIEW Tools Network, download the installer executable using the link provided in the email confirmation you received from NI. Launch the executable. 2. The QRCP installation screen should appear. 3. Click on CHECK FOR UPDATES to open the QRCP download page containing the latest QRCP version available. Note: The version of the QRCP Software is shown on the installation screen.

Transcript of Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping...

Page 1: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Install NI LabVIEW™ and Add-on RequirementsSTEP 1

Installation Guide: Quanser Rapid Control Prototyping Toolkit® 2016 for NI myRIO®

Install Quanser Rapid Control Prototyping Toolkit on Windows STEP 2

AUninstall any previous version of the Quanser Rapid Control Prototyping (QRCP) toolkit that may be present on the computer (e.g., QRCP 2012). Do so by launching the Programs and Features dialog from the Windows Control Panel.

Ensure that at least one version of 32-bit LabVIEW™ 2015 SP1 or 2016 is installed on the host computer with the following required add-ons:

1. LabVIEW™ NI myRIO Module

2. LabVIEW™ Control Design and Simulation Module

3. From the NI Device Drivers DVD: (a) Reconfigurable I/O (RIO) Feature (b) Real-Time and Embedded Feature4. LabVIEW™ Real-Time Module

5. LabVIEW™ MathScript RT Module (only used in certain curriculum VIs)

The Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1, or Windows 10 for the host system and select NI myRIO configurations as targets.

B 1. Insert the QRCP 2016 Installation DVD. If you purchased your QRCP through LABVIEW Tools Network, download the installer executable using the link provided in the email confirmation you received from NI. Launch the executable.

2. The QRCP installation screen should appear.

3. Click on CHECK FOR UPDATES to open the QRCP download page containing the latest QRCP version available.

Note: The version of the QRCP Software is shown on the installation screen.

Page 2: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

F

On the Setup Type installation screen, choose Typical.

CIf a more recent QRCP release is available on the QRCP download webpage, do the following. Otherwise, skip this step.

1. Download and run the latest QRCP 2016 installer, which consists of a single executable, named install_quanser_rcp_toolkit.exe .

2. A new QRCP installation screen should appear and replace the previous one.

3. Eject the QRCP Installation DVD, if a DVD was used to install the software.

GIf, during the installation, a Windows Security dialog box appears asking Would you like to install this device software?, check the Always trust software from the Quanser Consulting Inc checkbox and click on the Install button.

Note: If a dialog box Windows can’t verify the publisher of this driver software appears, click on the Install this driver software anyway option.

D E

Click on INSTALL to start the QRCP installation process.

Follow the steps of the installation wizard.

Page 3: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

A

B

Install NI LabVIEW Modules and the Quanser RCP Toolkit on NI myRIO TargetSTEP 3

Ensure the NI MyRIO device is listed in NI’s Measurement & Automation Explorer software under Remote Systems. If not, go to: www.ni.com/academic/ students/learn-rio/hardware

From the Windows Start menu, load the NI Measurement & Automation Explorer (MAX) software.

C

Expand the myRIO item under Remote Systems, right-click on the Software item, and select Add/Remove Software.

D

NI MAX software will prompt you to log in to myRIO. The default password is blank.

Follow the NI myRIO Getting Started Wizard to install the standard myRIO support software which includes LabVIEW™ Control Design and Simulation, LabVIEW™ Real-Time, and NI-RIO add-ons.

Page 4: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

H

G

Ignore this warning by clicking on Yes at the prompt.

IClick on Next and Finish in the upcoming prompts to install the required software.

E F

Select the Custom software installation.

Click on the Next button.

Select the following LabVIEW™ add-ons for your NI myRIO:

• Labview Control Design and Simulation

• LabVIEW Real-Time

• NI-RIO

• Quanser Rapid Control Prototyping toolkit for NI myRIO

Page 5: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

J

The Quanser Rapid Control Prototyping Toolkit for myRIO will now appear under the Software item of NI’s Measurement & Automation Explorer dialog window.

B

A

C

Using the RCA cable supplied with the Quanser myRIO terminal board, connect Analog Output Channel #0 (DAC #0) to Analog Input Channel #0 (ADC #0).

Ensure the NI myRIO is powered ON.

myRIO Test with Quanser Terminal Board for NI myRIOSTEP 4

NOTE: If you are connecting your NI myRIO directly to a Quanser workstation, please refer to the Testing section of your product’s Quick Start Guide. Quanser Terminal Board for NI myRIO is sold separately.

The Analog Loopback VI used in this section confirms that the QRCP has been installed properly on both Windows and the NI myRIO. It also tests the Quanser Terminal Board for NI myRIO . Ensure the terminal board is connected to myRIO’s MSP Connector C.

ADC

ENC

10

DAC10

10

Connect Quanser Terminal Board for NI myRIO to myRIO’s MSP Connector C.

Quanser Terminal board for NI myRIO

Page 6: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Double-click on the RCP CL HIL Analog Loopback Example.vi file listed under myRIO-1900-RCP.

G

LabVIEW™ VI Front Panel

F In the General category, enter the IP address of the myRIO in the IP Address field. The myRIO IP address can be found in NI’s Measurement & Automation Explorer dialog window. Click OK when set.

E

In the RCP CL HIL Analog Loopback Example.lvproj example, right-click on myRIO and select Properties.

D1. In LabVIEW™, open the NI ExampleFinder by selecting Find Examples... from the Help menu.

2. In the NI Example Finder dialog, when browsing according to Task, open the Toolkits and Modules/ Quanser Rapid Control Prototyping/Hardware folder.

3. Double-click on the RCP CL HIL Analog Loopback Example.lvproj LabVIEW™ project to open the RCP Toolkit example.

Page 7: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Open the VI Block Diagram (CTRL+E) and double-click on the HIL Initialize VI.

In the Board type treeview under the Main tab, select the ni_myrio_msp_c myRIO configuration (as the analog loopback cable is connected on the terminal board).

H I

N

L

KJ

Click on the STOP button to stop running the VI.

When manually moving the Analog Output Signal knob of the VI, both Analog Input and Analog Ouput scopes should display the same trace. If not, go to the Troubleshooting section.

Click on the OK button.

Click on the white arrow button to run the VI.

Scope view of the VI Front Panel

Configure HIL Initialize window

M

Go to the Front Panel of the VI (CTRL-E), pictured in Step 4.

Page 8: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Review the following recommendations before contacting technical support engineers.TROUBLESHOOTING

Getting ‘VI Missing‘ messages when opening the DAQ Test example VI.

When running the DAQ Test, the Analog Input scope does not read anything.

The NI myRIO does not appear in the Measurement & Automation Explorer window.

• Ensure NI LabVIEW™ and all the add-ons listed in Step 1 have been installed.

• Ensure the Quanser Rapid Control Prototyping toolkit has been installed, as detailed in Step 2 and 3.

• Ensure the RCA loopback connection is made on the Terminal Board on myRIO, as described in Step 4A.

• Verify that the ni_myrio_msp_c was selected in the HIL Initialize VI, as described in Step 4I.

• Check that the NI myRIO is powered correctly.

• Refer to National Insturment’s troubleshooting guide for the NI myRIO device at: https://www.decibel.ni.com/content/docs/DOC-30345

In order to contact Quanser for assistance, open the http://www.quanser.com webpage and click on the Tech Support link.

STILL NEED HELP? For further assistance visit ni.com/support or contact NI Support at 866-275-6964.

V.1.0©2016 Quanser Inc. All rights reserved. LabVIEW™ is a trademark of National Instruments. Windows is a registered trademark of Microsoft Corporation in the United States and other countries.

LEARN MORE To find out about the full range of Quanser control experiments, visit www.quanser.com

Page 9: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Install NI LabVIEW™ and Add-on Requirements

Install Quanser Rapid Control Prototyping Toolkit on Windows

STEP 1

STEP 2

A

B

A

Installation Guide: Quanser Rapid Control Prototyping Toolkit® 2016 for NI CompactRIO

Uninstall any previous version of the Quanser Rapid Control Prototyping (QRCP) toolkit that may be present on the computer (e.g., QRCP 2012). Do so by launching the Programs and Features dialog from the Windows Control Panel.

The Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1, or Windows 10 for the host system and select NI CompactRIO configurations as targets.

Ensure that at least one one version of 32-bit LabVIEW™ 2015 SP1 or 2016 is installed on the host computer with the following required add-ons:

1. LabVIEW™ Control Design and Simulation Module

2. From the NI Device Drivers (i.e., NI-DAQmx):

(a) Reconfigurable I/O (RIO) Feature (b) Real-Time and Embedded Feature

3. LabVIEW™ Real-Time Module

4. LabVIEW™ MathScript RT Module (only used in certain curriculum VIs)

Ensure the intended NI CompactRIO (cRIO) target is one of the currently supported NI cRIO systems:

• NI cRIO-9024 Real-Time Controller with NI cRIO-9113 or NI cRIO-9114 Chassis

• NI cRIO-9074 Real-Time Controller

Page 10: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

F

D E

On the Setup Type installation screen, choose Typical.

Click on INSTALL to start the QRCP installation process.

Follow the steps of the installation wizard.

CIf a more recent QRCP release is available on the QRCP download webpage, do the following. Otherwise, skip this step.

1. Download and run the latest QRCP 2016 installer, which consists of a single executable, named install_quanser_QRCP_toolkit.exe .

2. A new QRCP installation screen should appear and replace the previous one.

3. Eject the QRCP Installation DVD, if a DVD was used to install the software.

B 1. Insert the QRCP 2016 Installation DVD. If you purchased your QRCP through LABVIEW Tools Network, download the installer executable using the link provided in the email confirmation you received from NI. Launch the executable.

2. Click on CHECK FOR UPDATES to open the QRCP download page containing the latest QRCP toolkit version available.

Note: The version of the QRCP software is shown on the installation screen.

Page 11: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

A B

C

H

Once the installation is complete, click on EXIT to close the QRCP installation screen.

Install NI LabVIEW™ Modules and the Quanser RCP Toolkit on NI CompactRIO TargetSTEP 3

Refer to the Quanser Q1-cRIO module Quick Start Guide to ensure the NI CompactRIO hardware is properly set up with the Quanser Q1-cRIO module and connected to the Windows-based PC or laptop.

Ensure the NI CompactRIO device is listed in NI’s Measurement & Automation Explorer software under Remote Systems. If not, go to: http://www.ni.com/getting started/setuphardware/ compact rio/troubleshootmax.htm

From the Windows Start menu, load the NI Measurement & Automation Explorer (MAX) software.

GIf, during the installation, a Windows Security dialog box appears asking Would you like to install this device software?, check the Always trust software from the Quanser Consulting Inc checkbox and click on the Install button.

Note: If a dialog box Windows can’t verify the publisher of this driver software appears, click on the Install this driver software anyway option.

Page 12: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Double-click on the RCP CL HIL Analog Loopback Example.vi file listed under NI-cRIO.

F

LabVIEW™ VI Front Panel

E In the General category, enter the IP address of the CompactRIO in the IP Address field. The CompactRIO IP address can be found in NI’s Measurement & Automation Explorer dialog window. Click OK when set.

D

In the QRCP CL HIL Analog Loopback Example.lvproj example, right-click on NI-cRIO and select Properties.

C1. In LabVIEW™, open the NI ExampleFinder by selecting Find Examples... from the Help menu.

2. In the NI Example Finder dialog, when browsing according to Task, open the Toolkits and Modules/ Quanser Rapid Control Prototyping/Hardware folder.

3. Double-click on the QRCP CL HIL Analog Loopback Example.lvproj LabVIEW™ project to open the QRCP Toolkit example.

Page 13: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Open the VI Block Diagram (CTRL+E) and double-click on the HIL Initialize VI.

In the Board type options under the Main tab, select the q1_single cRIO configuration (as the analog loopback cable is connected on the Q1-cRIO module in Slot 1).

G H

M

K

JI

Click on the STOP button to stop running the VI.

When manually moving the Analog Output Signal knob of the VI, both Analog Input and Analog Ouput scopes should display the same trace. If not, go to the Troubleshooting section.

Click on the OK button.

Click on the white arrow button to run the VI.

Scope view of the VI Front Panel

Configure HIL Initialize window

L

Go to the Front Panel of the VI (CTRL-E), pictured in Step 4F.

Page 14: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

HSelect the following LabVIEW™ add-ons for your NI CompactRIO:

• LabVIEW™ Control Design and Simulation

• LabVIEW™ Real-Time

• NI-RIO

• Quanser Rapid Control Prototyping toolkit for NI CompactRIO

GIgnore this warning by clicking on Yes at the prompt.

E F

Select the Custom software installation.

Click on the Next button.

D

Expand the CompactRIO item under Remote Systems, right-click on the Software item, and select Add/Remove Software.

Page 15: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

I

J

The following list should now appear under the Software item of NI’s Measurement & Automation Explorer dialog window.

Click on Next and Finish in the upcoming prompts to install the required software.

A

B

Using the RCA cable supplied with the Quanser Q1-cRIO module, connect Analog Output Channel #0 (AO #0) to Analog Input Channel #0 (AI #0).

Ensure the NI CompactRIO and Quanser Q1-cRIO module are powered ON.

Q1-cRIO Test STEP 4

The Analog Loopback VI used in this section confirms that the QRCP has been installed properly on both Windows and the NI CompactRIO. It also tests the Quanser Q1-cRIO data acquisition (DAQ) device.

Ensure the NI CompactRIO (cRIO) is in one of the four RCP-supported configurations and that one Quanser Q1-cRIO module is inserted in Slot 1 of the cRIO chassis. Refer to the Quanser Q1-cRIO Module Quick Start Guide for more information about the supported cRIO configurations and how to set up the Q1-cRIO module.

AO0

AI0

Q1-cRIO

EI0

EI1

Page 16: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Review the following recommendations before contacting technical support engineerTROUBLESHOOTING

When running the DAQ Test, the Analog Input scope does not read anything.

Getting ‘VI Missing‘ messages when opening the DAQ Test example VI.

• Ensure NI LabVIEW™ and all the add-ons listed in Step 1 have been installed.

• Ensure the Quanser Rapid Control Prototyping toolkit has been installed, as detailed in Step 2 and Step 3.

• Ensure the RCA loopback connection is made on the Quanser Q1-cRIO module, as described in Step 4A.

• Verify that the q1_single was selected in the HIL Initialize VI, as described in Step 4H.

• Check that the Quanser Q1-cRIO is powered correctly. See the Quanser Q1-cRIO Quick Start Guide for instructions on how to connect the + and - terminals on the Quanser Q1-cRIO module.

The NI CompactRIO does not appear in the Measurement & Automation Explorer window.

• Refer to NI’s troubleshooting guide for the NI CompactRIO device at: http://www.ni.com/getting-started/set-up-hardware/compactrio/troubleshoot-max

STILL NEED HELP? For further assistance visit ni.com/support or contact NI Support at 866-275-6964.

V.1.0©2016 Quanser Inc. All rights reserved. LabVIEW™ is a trademark of National Instruments. Windows is a registered trademark of Microsoft Corporation in the United States and other countries.

LEARN MORE To find out about the full range of Quanser control experiments, visit www.quanser.com

Page 17: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Ensure that at least one version of 32-bit LabVIEW™ 2015 SP1 or 2016 is installed on the host computer with the following required add-ons:

1. LabVIEW™ Control Design and Simulation Module

2. NI Device Drivers (i.e., NI-DAQmx)

3. LabVIEW™ MathScript RT Module (only used in certain curriculum VIs)

Install NI LabVIEW™ and Add-on Requirements

Install Quanser Rapid Control Prototyping Toolkit on Windows

STEP 1

STEP 2

A

B

C

Installation Guide: Quanser Rapid Control Prototyping Toolkit® 2016 for Windows

Uninstall any previous version of the Quanser Rapid Control Prototyping (QRCP) toolkit that may be present on the computer (e.g., QRCP 2012). Do so by launching the Programs and Features dialog from the Windows Control Panel.

1. Insert the QRCP 2016 Installation DVD. If you purchased your QRCP through LABVIEW Tools Network, download the installer executable using the link provided in the email confirmation you received from NI. Launch the executable.

2. Click on CHECK FOR UPDATES to open the QRCP download page containing the latest version available.

Note: The version of the QRCP software is shown on the installation screen.

If a more recent QRCP version is available on the QRCP download webpage, do the following. Otherwise, skip this step.

1. Download and run the latest QRCP 2016 installer, which consists of a single executable, named install_quanser_rcp_toolkit.exe .

2. A new QRCP installation screen should appear and replace the previous one.

3. Eject the QRCP Installation DVD, if a DVD was used to install the software.

The Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1 or Windows 10.

Page 18: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

A

H

G

Using the RCA cable supplied with the data acquisition device, connect Analog Output Channel #0 (AO #0) to Analog Input Channel #0 (AI #0).

F

D E

On the Setup Type installation screen, choose Typical.

If during the installation, a Windows Security dialog box appears asking Would you like to install this device software?, check the Always trust software from Quanser Consulting Inc checkbox and click on the Install button.

Note: If a dialog box Windows can’t verify the publisher of this driver software appears, click on the Install this driver software anyway option.

The Analog Loopback VI used in this section is to confirm that the QRCP has been installed properly. It also tests the data acquisition (DAQ) device on Windows. Refer to the DAQ Quick Start Guide for more information about setting up the DAQ device.

Click on INSTALL to start the QRCP installation process.

Once the installation is complete, click on EXIT to close the QRCP installation screen.

DAQ Test on Windows STEP 3

Follow the steps of the installation wizard.

Analog Output(AO)

Analog Input(AI)

Data Acquisition Device

Page 19: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

In the Board type options under the Main tab, select the data acquisition device that is installed on the computer (e.g., q2_usb).

E F

Click on the OK button.

Configure HIL Initialize window

Open the VI Block Diagram (CTRL+E) and double-click on the HIL Initialize VI.

In the RCP CL HIL Analog Loopback Example.lvproj example, double-click on the RCP CL HIL Analog Loopback Example.vi file listed under My Computer.

DC

LabVIEW™ VI Front Panel

JClick on the STOP button to stop running the VI.

When manually moving the Analog Output Signal knob of the VI, both Analog Input and Analog Ouput scopes should display the same trace. If not, go to the Troubleshooting section.

Scope view of the VI Front Panel

I

HGClick on the white arrow button to run the VI.

Go to the Front Panel of the VI (CTRL-E) pictured in Step 3C.

B 1. In LabVIEW™, open the NI Example Finder by selecting Find Examples... from the Help menu.

2. In the NI Example Finder dialog, when browsing according to Task, open the Toolkits and Modules/Quanser Rapid Control Prototyping/Hardware folder.

3. Double-click on the RCP CL HIL Analog Loopback Example. lvproj LabVIEW™ project to open the RCP Toolkit example.

Page 20: Installation Guide: Quanser Rapid Control Prototyping ToolkitThe Quanser Rapid Control Prototyping (QRCP) toolkit supports either 32-bit or 64-bit Microsoft Windows 7, Windows 8.1,

Review the following recommendations before contacting technical support engineers.TROUBLESHOOTING

Getting ‘VI Missing‘ messages when opening the DAQ Test example VI.

When running the DAQ Test, the Analog Input scope does not read anything.

The NI DAQ device is not recognized: driver not installed.

• Ensure LabVIEW™ and all the add-ons listed in Step 1 have been installed.

• Ensure the Quanser Rapid Control Prototyping toolkit has been installed, as detailed in Step 2.

• Ensure the RCA loopback connection is made on the data acquisition (DAQ) device, as described in Step 3A.

• Verify that the proper DAQ device name was selected in the HIL Initialize VI, as described in Step 3E.

• Ensure the NI-DAQmx drivers are installed, as described in Step 1. The NI-DAQmx installer is on a DVD that comes with the NI hardware; it can also be downloaded from http://www.ni.com/drivers/.

• Verify the data acquisition (DAQ) device is properly connected to the computer.

STILL NEED HELP? For further assistance visit ni.com/support or contact NI Support at 866-275-6964.

V.1.0©2016 Quanser Inc. All rights reserved. LabVIEW™ is a trademark of National Instruments. Windows is a registered trademark of Microsoft Corporation in the United States and other countries.