Company ProfileTeknoware OY was established in 1972 with the objective of producing electronic items for interior lighting of buses. It was a time when �uorescent lamps were introduced for commercial vehicles as an alternative to the normal incandescent bulb providing lower energy consumption and longer life. However, before there were certain limitations to these lamps. They needed special electronic units as they could not be driven directly from the vehicle’s DC power supply.
Teknoware introduced several novel solutions, which provided both higher reliability and superior passenger comfort while in use. Soon the product o�ering expanded to o�er complete lighting systems for all mass transport vehicles including Railways. Today, Teknoware provides lighting solutions to several market leading brands such as Mercedes Benz, Volvo, Irisbus, Bombardier, Alstom and Siemens to name a few.
In the late 70’s, the product range expanded to include emergency lighting for buildings. Since then there has been constant product development going on. Today the product solutions have technically very little in common with the early design. However, they still share the same innovativeness and passion for improved design, quality control and reliability.
Teknoware has since then won many esteemed awards for innovation and new technology. Teknoware is a global leader in special lighting applications and one of the reputed supplier in Europe, Middle East, Africa and Asia Paci�c.
In May 2008, Teknoware took a very important step towards serving the Middle East region by starting its own regional o�ce in Dubai - Teknoware Middle East FZCO within the Dubai Airport Free Zone. Before that Teknoware has been serving the Middle East market directly from the Finland O�ce.
With a local presence, Teknoware is today in a position to provide the same level of service that has made the company a market leader in Scandanavia and one of the leading names in Europe. Teknoware, has in a short span of time, supplied to more than 100 projects in the region. Key projects that the regional o�ces continue to service include JAL Towers, Dubai Metro, Emirates PTI Hotels, Dorra Bayat Dubai Marina and Dubai Gate Towers at Jumeirah Lake Towers area and Porto Arabia in Pearl Qatar.
INNOWAREBy TEKNOWARE
Dubai Metro
Abu Dhabi Mall The H Hotel
Sadiyat Beach ApartmentsSadiyat Beach Apartments
Deira City Centre
King Abdullah Financial District
INNOWAREBy TEKNOWARE
index
Emergency Lights
Exit Lights
Photometric Data
Ordering Block Summary
Central Battery System
Design Concept
Pg. 1-8
Pg. 9-12
Pg. 13
Pg. 14
Pg. 15-16
Pg. 17-18
INNOWAREBy TEKNOWARE
NovaLite (MINI)Innoware's range of 8 Watt Bulkhead surface mounted Emergency lights are available in three sizes. Di�users with clear or opal color are also available. Semi recessed bezel available.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Pictogram Options
PB051
PB052
PB053
Maintained
Part Number IW0841F-M
Non Maintained
IW0841F-NM
Body in Moulded ABS - RAL9010, Polycarbonate di�user.185
105
180/90/60 MinsEmergency Duration
Emergency O/P Lumens
Maintained O/P Lumens
Construction
WeightDimensionsCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourceMonitorOperating TemperatureIP RatingOptionsWarranty
1 Kg345x85x80mm20mm knockouts on side of the �tting220 240V AC 50/60Hz16VA 3.2VA24 hours for full 3 hour durationNiCad 2 x 1.2V8W T5 �uorescentHigh Intensity Green LED Monitoring AC Power & Battery Charging status0 to +25 CIP 65Semi-Recess Bezel BZ-041 Available with Auto Test /AT1 Year
~
Modes
Easy to installAC Status through LEDHinged removable geartrayLow MaintenanceLow Cost
Features:
IP 65
1
INNOWAREBy TEKNOWARE
2
NovaLite (Standard)Innoware's range of 8 Watt Bulkhead surface mounted Emergency lights. Di�users with clear or opal color are also available. Semi recessed bezel available.
Features:Easy to installAC Status through LEDHinged removable geartrayLow MaintenanceLow Cost IP 65
Maintained
Part Number IW0842F-M
Non Maintained
IW0842F-NM
Body in Moulded ABS - RAL9010, Polycarbonate di�user.
185105
180/90/60 MinsEmergency Duration
Emergency O/P Lumens
Maintained O/P Lumens
Construction
WeightDimensionsCable EntrySupply VoltagePower ConsumptionRecharge Period
BatteryLight SourceMonitorOperating TemperatureIP RatingOptionsWarranty
1 Kg355x125x85mm20mm knockouts on side of the �tting220 240V AC 50/60Hz
16VA 3.2VA24 hours for full 3 hour durationNiCad 2 x 1.2V8W T5 �uorescentHigh Intensity Green LED Monitoring AC Power & Battery Charging status0 to +25 C
IP 65Semi-Recess Bezel BZ-042 Available with Auto Test /AT1 Year
~
Modes
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals
Pictogram Options
PB054
PB055
PB056
INNOWAREBy TEKNOWARE
3
NovaLite (LARGE)Innoware's range of 8 Watt Bulkhead surface mounted Emergency lights. Di�users with clear or opal color are also available.
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals
Pictogram Options
PB057
PB058
PB059
Maintained
Part Number IW0843F-M
Non Maintained
IW0843F-NM
Body in Moulded ABS - RAL9010, Polycarbonate di�user.
185105
180/90/60 MinsEmergency Duration
Emergency O/P Lumens
Maintained O/P Lumens
Construction
WeightDimensionsCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourceMonitorOperating TemperatureIP RatingOptionsWarranty
1.3 Kg380x140x90mm20mm knockouts on side of the �tting220 240V AC 50/60Hz
16VA 3.2VA24 hours for full 3 hour durationNiCad 2 x 1.2V8W T5 �uorescentHigh Intensity Green LED Monitoring AC Power & Battery Charging status0 to +25 CIP 65Available with Auto Test /AT1 Year
~
Modes
Easy to installAC Status through LEDHinged removable geartrayLow MaintenanceLow Cost
Features:
IP 65
INNOWAREBy TEKNOWARE
4
TrimLiteInnoware's range of 8 Watt Fully recessed Emergency lights o�ers a cost e�ective emergency lighting solution for a wide range of solutions. The di�user is also available in engraved pattern, clear acrylic or silkscreen �nishes.
Features:Easy to installAC Status through LED
Maintained
Part Number IW0852F-M
Non Maintained
IW0852F-NM
Body is sheet steel painted RAL9010, Plastic di�user
185105
180/90/60 MinsEmergency Duration
Emergency O/P Lumens
Maintained O/P Lumens
Construction
WeightDimensionsCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourceMonitorOperating TemperatureIP RatingOptionsWarranty
2 Kg310x14020mm knockouts on side of the �tting220 240V AC 50/60Hz
16VA 3.2VA24 hours for full 3 hour duration
NiCad 2 x 1.2V8W T5 �uorescentHigh Intensity Green LED Monitoring AC Power & Battery Charging status0 to +25 CIP 20Available with Auto Test /AT1 Year
~
Modes
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals
INNOWAREBy TEKNOWARE
5
FlashLite - RA robust IP65 luminaire suitable for interior and exterior applications. Employs a 28 Watt 2D luminaire for maximum e�ciency and cost e�ective solution. The di�user is also available in clear or opal color
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals, Factories/Warehouses
Maintained
Part Number IW2872D-M
Non Maintained
IW2872D-NM
Round pro�le 2D luminaires, hinged gear tray for easy installation and maintenance.
500205
180/90/60 MinsEmergency Duration
Emergency O/P Lumens
Maintained O/P Lumens
ConstructionWeightDimensionsCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourceOperating TemperatureIP RatingWarranty
2.2 Kg320(dia) x 105mm20mm knockouts on side of the �tting220 240V AC 50/60Hz55VA 12VA24 hours for full 3 hour durationNiCad 2 x 1.2V28W 2D0 to +25 CIP 651 Year
~
Modes
Easy to installRound Pro�leLow MaintenanceLow Cost
Features:
IP 65
INNOWAREBy TEKNOWARE
6
FlashLite - SA robust IP65 luminaire suitable for interior and exterior applications. Employs a 28 Watt 2D luminaire for maximum e�ciency and cost e�ective solution. The di�user is also available in clear or opal color
Features:Easy to installSquare Pro�leLow MaintenanceLow Cost
IP 65
Maintained
Part Number IW2882D-M
Non Maintained
IW2882D-NM
Body is moulded ABS RAL 9010
500205180/90/60 MinsEmergency Duration
Emergency O/P LumensMaintained O/P Lumens
Construction
WeightDimensionsCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourceOperating TemperatureIP RatingWarranty
2.3 Kg295x295x95mm20mm knockouts on side of the �tting220 240V AC 50/60Hz55VA 12VA24 hours for full 3 hour duration
NiCad 2 x 1.2V28W 2D0 to +25 CIP 651 Year
~
Modes
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals, Factories/Warehouses
INNOWAREBy TEKNOWARE
TwinLiteThese luminaires incorporate either 2x20W Halogen lamps or 12W high power LEDs per head. The lamps are adjustable with polycarbonate lenses.
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:Process Plants, Stadium, Loading Bays, Mechanical Rooms
Non Maintained
Part Number IW4062H-NM
Non Maintained
IW4062L-NM
Rectangular sheet steel housing in RAL9010. Adjustable lamps with polycarbonate lenses2 x 260
3 hoursEmergency Duration
Emergency O/P LumensConstruction
WeightDimensionsCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourceMonitor
Operating Temperature
IP Rating
Warranty
High Intensity Green LED Monitoring AC Power & Battery Charging status, Lamp connection.
8 Kg 5 Kg310x190mm20mm knockouts on side of the �tting220 240V AC 50/60Hz12VA 12VA 24 hours for full 3 hour duration
SLA 2x12V SLA 1x12V20W Halogen /head 12 x power LED / head
0 to +25 C
IP 20
1 Year
Modes
~
Easy to install with removable chassis plateAC Status Monitoring Through LEDLow MaintenanceLow Cost
Features:
7
INNOWAREBy TEKNOWARE
8
LED LightsAt Teknoware, we believe that the future in emergency lighting lies with LED lighting with its advantages of having higher lifetime, lower power consumption and better luminous characteristics. The relatively small sizes of LEDs along with the �exibility of adjusting colour, colour temperature and intensity have opened whole new possibilities to lighting designers. Due to the continuous testing, research and design work conducted by Teknoware’s product development unit, we at Teknoware are familiar with the latest developments in LED technology and can choose the most suited LEDs for each location. Optimizing the choice of LED type can have a signi�cant e�ect on the lighting’s life cycle cost. One can safely rely on the solutions recommended by Teknoware to be �t for the purpose. We take responsibility for designing the optimal solution for your environment by minimizing the number of individual lights while maximizing the light output level.
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Our service includes:
Light level simulations (3D illustration) to design optimal lighting in terms of cost and properties.Expert planning of the thermal and optical properties of LED lighting.Range of lenses for LED lights to meet customers’ varying needs.In-depth LED know-how to implement even the challenging plans of interior designers
For further information, kindly contact [email protected]
Our LED lights are available in the 3 modes -
Addressable lights for Central Battery SystemsSelf Contained lights with battery backup230VAC general lights to meet any lighting design requirements.
INNOWAREBy TEKNOWARE
OnyXInnoware's range of 8 Watt recessed Exit luminaires is designed and manufactured to the highest standards of performance and reliability.
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals
Pictogram Options
PB040
PB041
PB042
Maintained
Part Number IW0822F-M
Body is sheet steel painted RAL9010. Fully recessed with spring clips for simple installation. Legend with clear acrylic/engraved pattern
180/90/60 Mins26 metersMaximum Viewing Distance
Emergency DurationConstruction
WeightCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourcePictogram DimensionOperating TemperatureIP RatingOptionsWarranty
2.5 Kg20mm knockouts on side of the �tting220 240V AC 50/60Hz16VA 24 hours for full 3 hour durationNiCad 2 x 1.2V8W T5 �uorescent280(l) x 130(w)0 to +25 CIP 20Available with Auto Test /AT1 Year
~
Modes
Easy to installLow MaintenanceLow Cost
Features:
9
INNOWAREBy TEKNOWARE
DecorX8 Watt Surface mounted or Hanging type EXIT lights o�ers a cost e�ective emergency lighting solution for a wide range of solutions and very aesthetic for most applications available in single and double sided versions. The legend is available with clear acrylic / engraved pattern. Suspension brackets and chains are also available with this series.
Features:Simple to installAC Status through LED
Ultra Low MaintenanceLow Cost
Maintained
Part Number IW0812F-M
Rectangular sheet steel housing. Legend with clear acrylic /engraved pattern180/90/60 Mins26 metersMaximum Viewing Distance
Emergency DurationConstruction
WeightCable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourcePictogram DimensionMonitorOperating TemperatureIP RatingOptionsWarranty
2.4 Kg (Wall) / 3.5Kg (Ceiling)20mm knockouts on side of the �tting220 240V AC 50/60Hz16VA 24 hours for full 3 hour durationNiCad 2 x 1.2V8W T5 �uorescent280(l) x 130(w)High Intensity Green LED Monitoring AC Power & Battery Charging status0 to +25 CIP 20Available with Auto Test /AT1 Year
~
Modes
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals
Pictogram Options
PB046
PB047
PB048
OptionsWhite /WGold /GWith Chains +C
10
INNOWAREBy TEKNOWARE
11
VertX (14cm)Innoware's VertX range is a cost conscious, single sided , low pro�le unit for surface mounting. The rectangular housings constructed from self-extinguishing sheet steel are tough and highly durable.
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers, Clubs, Schools/Universities, Hospitals,Factories/Warehouses
Pictogram Options
PB043
PB044
PB045
Maintained
Part Number IW0831F-M
Rectangular sheet steel housing incorporating opal Exit screen. Colour RAL9010180/90/60 Mins
23 metersMaximum Viewing DistanceEmergency DurationConstruction
WeightCable Entry
Supply VoltagePower ConsumptionRecharge PeriodBatteryLight SourcePictogram DimensionMonitorOperating TemperatureIP RatingOptionsWarranty
1.7 Kg20mm knockouts on side of the �tting
220 240V AC 50/60Hz16VA 24 hours for full 3 hour durationNiCad 2 x 1.2V8W T5 �uorescent286(l) x 125(w)High Intensity Green LED Monitoring AC Power & Battery Charging status0 to +25 CIP 20Available with Auto Test /AT1 Year
~
Modes
Simple to installLow MaintenanceLow Cost
Features:
INNOWAREBy TEKNOWARE
12
VertX (20cm)Innoware's VertX range is a cost conscious, single sided , low pro�le unit for surface mounting. The rectangular housings constructed from self-extinguishing sheet steel are tough and highly durable.
Maintained
Part Number IW0832F-M
Rectangular sheet steel housing incorporating opal Exit screen. Colour RAL9010180/90/60 Mins
40 metersMaximum Viewing DistanceEmergency DurationConstruction
Weight
Cable EntrySupply VoltagePower ConsumptionRecharge PeriodBatteryLight SourcePictogram DimensionMonitorOperating TemperatureIP RatingOptionsWarranty
2 Kg
20mm knockouts on side of the �tting
220 240V AC 50/60Hz16VA 24 hours for full 3 hour durationNiCad 2 x 1.2V8W T5 �uorescent370(l) x 185(w)High Intensity Green LED Monitoring AC Power & Battery Charging status0 to +25 CIP 20Available with Auto Test /AT1 Year
~
Modes
Simple to installLow MaintenanceLow Cost
Features:
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Applications:O�ces, Hotels,Restaurants, Shopping Centers,Clubs, Schools/Universities, Hospitals
Pictogram Options
PB043
PB044
PB045
INNOWAREBy TEKNOWARE
13
Photometric Data
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Model Number
Transverse to Wall
Transverse Spacing
Axial to wall
Axial Spacing
Mounting Height
0.5 1.0 0.5 1.0 0.5 1.0 0.5 1.0
IW0852F-M2.5
4.0
6.0
1.4
1.0
n/a
1.1
n/a
n/a
4.4
4.0
n/a
4.0
2.8
n/a
1.4
1.0
n/a
n/a
n/a
n/a
4.4
4.0
n/a
3.2
n/a
n/a
IW0852F-NM2.5
4.0
6.0
1.6
1.1
n/a
1.3
n/a
n/a
4.9
4.5
n/a
4.5
3.1
n/a
1.6
1.1
n/a
n/a
n/a
n/a
4.9
4.5
n/a
3.6
n/a
n/a
IW2872D-M/NM2.5
4.0
6.0
2.8
2.5
n/a
1.9
n/a
n/a
7.3
7.7
6.6
5.5
4.9
n/a
2.8
2.5
n/a
1.9
n/a
n/a
7.3
7.7
6.6
5.5
4.9
n/a
IW2882D-M/NM2.5
4.0
6.0
2.8
2.5
n/a
1.9
n/a
n/a
7.3
7.7
6.6
5.5
4.9
n/a
2.8
2.5
n/a
1.9
n/a
n/a
7.3
7.7
6.6
5.5
4.9
n/a
IW4062H4.0
6.0
8.0
10.4 (0.2 lux)
10.6(0.2 lux)
11.6(0.2 lux)
5.2
5.0
4.4
25.2(0.2 lux)
26.6(0.2 lux)
28.6(0.2 lux)
13.3
12.4
11.2
10.4(0.2 lux)
10.6(0.2 lux)
11.6(0.2 lux)
5.2
5.0
4.4
25.2(0.2 lux)
26.6(0.2 lux)
28.6(0.2 lux)
13.3
12.4
11.2
IW4062L4.0
6.0
8.0
10.4(0.2 lux)
10.6(0.2 lux)
11.6(0.2 lux)
5.2
5.0
4.4
25.2(0.2 lux)
26.6(0.2 lux)
28.6(0.2 lux)
13.3
12.4
11.2
10.4(0.2 lux)
10.6(0.2 lux)
11.6(0.2 lux)
5.2
5.0
4.4
25.2(0.2 lux)
26.6(0.2 lux)
28.6(0.2 lux)
13.3
12.4
11.2
IW0841F/IW0842F/IW0843F - M
2.5
4.0
6.0
1.6
1.2
n/a
1.4
n/a
n/a
5.0
4.5
n/a
4.5
3.2
n/a
1.6
1.2
n/a
0.9
n/a
n/a
5.0
4.5
n/a
3.6
n/a
n/a
IW0841F/IW0842F/IW0843F -NM
2.5
4.0
6.0
1.8
1.3
n/a
1.5
n/a
n/a
5.5
5.0
n/a
5.0
3.5
n/a
1.8
1.3
n/a
1.0
n/a
n/a
5.5
5.0
n/a
4.0
n/a
n/a
Spacing in meters on Emergency Escape Routes
INNOWAREBy TEKNOWARE
14
Model Number Type of �tting Mode Description
IW0852F Recessed EM IW0852F-M /X 8 Watt Maintained
IW2872D Round Bulkhead IW2872D-M /X 28 Watt Maintained (Round)
IW2872D-NM /X 28 Watt Non-Maintained (Round)
IW2882D Square BulkheadIW2882D-M /X 28 Watt Maintained (Square)
IW2882D-NM /X 28 Watt Non-Maintained (Square)
IW4062H Twinspot Halogen IW4062H-NM /X 2 x 20 Watt Non-Maintained (Halogen)
IW4062L Twinspot LED IW4062L-NM /X 2 x 12 Power LED Non-Maintained (LED)
IW0841F/IW0842F/IW0843F
Small/Standard/Large Bulkhead
IW0841F-M /X 8 Watt Maintained (Mini)
IW0841F-NM /X 8 Watt Non-Maintained (Mini)
IW0842F-M /X 8 Watt Maintained (Standard)
IW0842F-NM /X 8 Watt Non-Maintained (Standard)
IW0843F-M /X 8 Watt Maintained (Large)
IW0843F-NM /X 8 Watt Non-Maintained (Large)
IW0831F /IW0832F Exit BoxIW0831F-M /X 8 Watt Maintained (14cm version)
IW0832F-M /X 8 Watt Maintained (20cm version)
IW0822F Recessed Exit IW0822F-M /X 8 Watt Maintained (Recessed)
IW0812F Surface Mounted Exit IW0812F-M /X 8 Watt Maintained (Surface)
Ordering Block Summary
X - Available with 60/90/180mins Battery backup
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
INNOWAREBy TEKNOWARE
Teknoware Central Battery System is an automatic monitoring & self testing system, where the batteries are located in a single location feeding power to all the emergency & Exit lights connected to it. The Central Battery System does not require regular visits to individual lights for its maintenance and failure checks. In case of a power failure, the CBS panel switches ON all the Emergency lights connected to it providing power from the batteries near it. The advantage of using a Central Battery system is that each of the luminaires connected to the panel have a unique address and any luminaire/battery/panel failure is easily noti�ed to the maintenance team.
If required, the batteries in a Central Battery System can be designed for a life of up to 25 years. When these batteries are required to be changed, it is much easier and quicker. Much higher lighting levels can also be achieved by using Central Battery Systems.
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
Central Battery System
TKT 67Series
TKT6716C 2 x (8x350W / 4x700W / 2x1400W) 5600 W 5600 WTKT6724C 3 x (8x350W / 4x700W / 2x1400W) 8400 W 8400 WTKT6732C 4 x (8x350W / 4 x700W / 2x1400W) 11200 W 11200 WTKT6740C 5 x (8x350W / 4 x700W / 2x1400W) 14000 W 14000 WTKT6748C 6 x (8x350W / 4 x700W / 2x1400W) 16800 W 16800 WTKT6756C 7 x (8x350W / 4 x700W / 2x1400W) 19600 W 19600 W
TKT6608C 1 x (8x350W / 4x700W / 2x1400W) 2000 W 2800 WTKT6616C 2 x (8x350W / 4x700W / 2x1400W) 2580 W 3340 WTKT6624C 3 x (8x350W / 4x700W / 2x1400W) 2580 W 3340 W
TKT 66Series
TKT 65Series
TKT6508C 8 x 250W 2000 W 2800 WTKT6516C 16 x 250W 2580 W 3340 WTKT6524C 24 x 250W 2580 W 3340 W
Maximum Total Load(1-3h Duration)
Maximum Load Maintained Luminaires
Outputs Type of the Panel
Panel Series
15
INNOWAREBy TEKNOWARE
16
Typical Schematic
PC with Monitoring Software
Maintained and Non-maintained luminaire can be connected on the same circuit
RS-485 to USB Converter
PENL
PENL
Third Party Interface
All the Tapsa Central Battery panels of Teknoware can be interfaced via BACnet or LON protocolto third party Building or Property Management Systems
Contact
For further information on Central Battery Systems, please contact :Asia Paci�c, Middle East and Africa Region:Teknoware Middle East FZCOPO Box: 118688, DubaiLIU, H12, Dubai Airport Free ZoneDubai, United Arab EmiratesTelephone: +971 4 2993622, Telefax: +971 4 2993623Email: [email protected]: www.teknoware.ae
Teknoware ME reserves all rights to modify the above contents without prior noti�cation.
INNOWAREBy TEKNOWARE
Design Stage 1
Requirements, Standards & Speci�cations The design speci�cation, selection and installation of emergency lighting is covered by an extensive range of International legislation / standards and local authority jurisdictions. The project speci�c requirements anduser / customer preferences should also be considered in this initial stage of design. The commonly used standards are EN Standards and BS Standards.
Design Stage 2
Mandatory Lighting locations Risk Assessment comprises the next stage of positioning and selecting the emergency lighting equipmentaccording to the nature of area to be protected. This should cover speci�c hazards and highlight safety equipment and signs. The pictures covers most of the areas to be covered by the System.
Design Stage 3
Exit Signage
Directional sign is required when sight of an emergency exit is not possible or doubt may exist. It should be noted that all the emergency escape route signs and luminaires should be of the same design format till the �nal emergency escape exit
Plants and switch rooms
To cover moving walkways and escalators
Toilets exceeding 8 square meters
At every exit door Whenever the direction of exit is ambiguous
Near changesof direction Ensure signs are of a suitable size for
viewing, if not add additional supplementary signs
Design Concept
Teknoware ME reserves the right to amend the above without prior information.
17
INNOWAREBy TEKNOWARE
Design Stage 4
Escape routes lighting level After positioning of all mandatory luminaires and exit signages, it maybe necessary to provide additional luminaires so that a required light level is reached along a escape route. This is done by identifying the maximum permissible distance between each luminaire type or from the wall. The photometric data of the luminaire clearly provides the distance so that the required lux level is maintained.
Design Stage 5
Lux Level Calculations
Lux level calculation provides a detailed graphical representation showing the lux levels and the number of luminaires that would be required to su�ce the requirement by the relevant standards and regulations.
Design Stage 6
Self-contained or Central Battery System?
Self contained system utilzes their own battery, charger and changeover circuits. They also includeconversion kits that can be used to enhance mains �uorescent luminaires, enabling them to provide illumination in the event of a normal power supply failure.
The Central Battery system is linked to a remote back-up power supply which provides power in the event of a normal power supply failure. These are easier to test & maintain and are suitable & cost e�ective for larger installations.
Design Stage 7
Testing and Maintenance
The tasks that include the testing and maintenance should also be considered in the design as they would ensure complete system integrity and capacity to ful�l its task at all times. Essential servicing should be well de�ned to ensure that the system is fully operational.
Teknoware ME reserves the right to amend the above without prior information.
18
INNOWAREBy TEKNOWARE
Asia Pacific, Middle East and Africa Region:Teknoware Middle East FZCO
PO Box: 118688 Dubai LIU, H12, Dubai Airport Free Zone
United Arab EmiratesTelephone: +971 4 2993622
Telefax: +971 4 2993623 Email: [email protected]
Website: www.teknoware.ae
Head Office: Teknoware OY
IImarisentie 8, FI-15200Lahti, Finland
INNOWAREBy TEKNOWARE