3D Smart Sensor – Your assistant on mobile machinesTrue 3D vision sensor
Camera systems for mobile machines
(11.2014)
(11.2014)
Industrial imaging
Sensors for factory automation with correction factor K=1Electromagnetic field immune ”K=1“ sensors for welding applications
Inductive sensors
Photoelectric sensors for general applications
When oil is all over – The new O6 coolantThe new compact O6 photoelectric sensors with infrared light“O6 wetline” now with IO-Link
(11.2015)
(04.2015)
(11.2014)
(11.2015)
(11.2015)
Position sensors
6 - 78 - 9
Capacitive touch sensors in compact M22 design
Capacitive sensors
(04.2015) 10 - 11
New pressure-resistant position sensors
Magnetic sensors
(04.2015) 12 - 13
14 - 1516 - 1718 - 19
Laser sensors / distance measurement sensors
PMD O5D – Now also with laser class 1OID with time of flight measurement (PMD) and easy-turn, laser class 1PMDLine M30 compact: time of flight technology and IO-Link
(11.2014)
(11.2014)
(04.2015)
20 - 2122 - 2324 - 25
40 - 4142 - 43
Intelligent incremental encoder with display and IO-LinkProgrammable incremental encoder with IO-Link
Encoders
(04.2015)
(04.2015)
Sensors for motion control
26 - 2728 - 29
High-resolution 3D camera for innovative vision integration
3D cameras
(11.2015) 48 - 49
Robust and precise inclination sensors – Now with IO-LinkPrecision for all inclinations
Inclination sensors
(11.2015)
(11.2014)
30 - 3132 - 33
Easy level controlSensor signals switch relaySafe monitoring of underspeed
Pulse evaluation systems
(04.2015)
(04.2015)
(04.2015)
34 - 3536 - 3738 - 39
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
Completeness monitoring for the packaging technologyVolume determination for storage and conveyor technology
3D sensors
(11.2015)
(11.2015)
44 - 4546 - 47
TOP
TOP
TOP
TOP
TOP
4
Flow sensors / flow meters
New benchmark in thermal flow measurementThe alternative: Vortex sensor instead of vaneNew flow sensor now also for smallest quantitiesThe smart float-type flow meter
(11.2015)
(04.2015)
(11.2015)
(04.2015)
58 - 5960 - 6162 - 6364 - 65
Safety 4.0: the safe SmartPLCWith signal effect: AS-i module for OSSD inputs
AS-Interface Safety at Work
(11.2015)
(11.2015)
Industrial communication
86 - 8788 - 89
8-port IO-Link master: closing the gap in the fieldIO-Link I/O module minimises wiring costs for sensors
IO-Link components
(04.2015)
(04.2015)
90 - 9192 - 93
8-port IO-Link master module with LINERECORDER AGENT embeddedIO-Link – The standard interface for smart sensorsIndustry 4.0 made easy – Apps instead of expensive programming
System solutions
(04.2015)
(04.2015)
(11.2015)
94 - 9596 - 9798 - 99
Temperature sensors
Evaluates temperatures up to 600 °C: the TR with a new lookModern classic: new TN temperature sensor200° below 2 s: fast, hygienic temperature transmitterSmall but effective: temperature transmitter in compact housingExtra protection for temperature sensors
(11.2015)
(11.2015)
(04.2015)
(11.2014)
(11.2014)
Process sensors
76 - 7778 - 7980 - 8182 - 8384 - 85
Hygienic point level sensor especially for hazardous areasContinuous level measurement in harsh environmentsMaintenance-free overflow protection to WHGLevel sensor with modular probe conceptContinuous level measurement with analogue output and IO-Link
(11.2015)
(11.2015)
(04.2015)
(04.2015)
(04.2015)
Level sensors
66 - 6768 - 6970 - 7172 - 7374 - 75
Pressure sensors
Small and cost-optimised for mobile machinesHydrostatic level measurement for a wide range of applicationsAn update for the bestseller: PN pressure sensor with a new lookIO-Link display: process values at a glance
(11.2015)
(04.2015)
(04.2015)
(11.2015)
50 - 5152 - 5354 - 5556 - 57
RFID for mobile machinesAdapters to increase the ranges of the new RFID antennas
RFID 125 kHz / RFID 13.56 MHz
(11.2015)
(11.2015)
Identification systems
100 - 101102 - 103
Industrially-compatible multicode reader with text recognition
1D/ 2D code readers
(04.2015) 104 - 105
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
TOP
5
Intelligent vibration sensor – Simply smartFlexible data logger for vibration and process valuesNew parameter software with data visualisation
Vibration monitoring systems
(11.2015)
(04.2015)
(04.2015)
Condition monitoring systems
Power management in mobile vehicles
Mobile controllers
(11.2015)
Systems for mobile machines
106 - 107108 - 109110 - 111
112 - 113
Parameter setting software for IO-Link sensors
LINERECORDER SENSOR 4.0
(04.2015)
Software
122 - 123
From factory automation to machine tool industryThe reliable connection even with strong noise field interference
Sockets
(11.2015)
(04.2015)
Connection technology
114 - 115116 - 117
For hygienic and wet areas in the food industryThe secure connection even in difficult applications
T splitters
(11.2015)
(11.2015)
118 - 119120 - 121
Gesamtkatalog EN 2015_Stilvorlage LK FrutigerOT_2010 DE_GB.qxd 17.11.14 12:50 Seite 3
6
Inductive sensors for factoryautomation with correctionfactor K=1
Constant correction factor”K=1“ sensors have the same sensing range for alltypes of metals. They are for example perfectly suitedfor the detection of aluminium, where conventionalsensors show a considerably reduced sensing range.The high switching frequencies enable the monitoringof fast changing switching states. With the new sensortechnology, these sensors are insensitive to magneticfields and can for example be reliably used right next toelectrical brakes. The wide temperature range as wellas the high protection ratings enable universal use ofthe new ”K=1“ sensors.
Uniform sensing range for the reliable detection of all metals
Compact dimensions for use in the smallest of space
Electromagnetic field immune sensortechnology to prevent incorrect switching
Wide temperature range for universal use
High protection ratings up to IP 68 / IP 69K
One sensing range for all metals
Position sensors
7
(11.2015)
Inductive sensorsPosition sensors
Dimensions
Example IFS290
Example IFS285
Example IGS280
Example IFS277
Example IIS269
Example IIS268
Sensing range
[mm]
Current rating
[mA]
Switching frequency
[Hz]
Ordernumber
M12 connector · 3 wire DC PNP · Output function normally open
45 4 1002000 IFS289M12
M12
M12
M12
M18
M18
45 10 1002000 IFS290
60 4 1002000 IFS285
60 10
Installation
flush
non-flush
flush
non-flush 1002000 IFS286
45 8 1002000 IGS279
45 15 1002000 IGS280
flush
non-flush
M18
M18
60 8 1002000 IGS277
60 15 1002000 IGS278
flush
non-flush
M30
M30
45 15 1002000 IIS269
60 15 1002000 IIS267
flush
flush
M30 60 30 1002000 IIS268non-flush
Type Total length
[mm]
Operating voltage [V DC] 10...30
Reverse polarity protection •
Short-circuit protection •
Overload protection •
Protection rating IP 65 / IP 66 / IP 67 / IP 68 / IP 69K
Protection class III
Ambient temperature [°C] -40...85
Output status indication [LED] yellow (4 x 90°)
Further technical data
Connection technology
Type Version Ordernumber
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
For further technical details please visit: www.ifm.com
Housing materials
brass plated with white bronze,
sensing face LCP
3425
M12
x1
174
M12
x1
45
LED 4 x 90°
5
4945
M12
x1
M12
x1
60
LED 4 x 90° 174
LED 4 x 90°
453430
1015
M12
x1
4
M18
x1
24
M18
x1
M12
x1
4549
60
LED 4 x 90° 244
45
M30
x1,5
4960
M12
x1
LED 4 x 90° 5 36
4549
60
22,5
M30
x1,5
M12
x1
LED 4 x 90° 5 36
8
Electromagnetic field immune”K=1“ sensors for welding applications
Use in harsh welding applicationsThe inductive ”K=1“ sensors withstand harsh operatingconditions and reliably detect metal objects even incase of soiling.The sensor housing and the fixing nuts have a non-stickcoating to prevent sticking of weld slag. Strong magnetic fields occur in welding processes. The new sensor technology prevents incorrect switching.The quick connection with the connector and matchingcable from the ecolink range is the ideal basis for permanent use.
Uniform sensing range for the reliable detection of all metals
Robust design with non-stick coating
Electromagnetic field immune sensortechnology to prevent incorrect switching
Wide temperature range for universal use
High protection ratings up to IP 68 / IP 69K
One sensing range for all metals
Position sensors
9
(11.2015)
Inductive sensorsPosition sensors
Dimensions
IFW204
IGW202
IIW202
Sensing range
[mm]
Currentload[mA]
Switching frequency
[Hz]
Ordernumber
M12 connector · 3 wire DC PNP · Output function normally open
65 4 1002000 IFW204M12
M18
M30
65 8 1002000 IGW202
65 15 1002000 IIW202
Installation
flush
flush
flush
Type Total length
[mm]
Operating voltage [V DC] 10...30
Current consumption [mA] < 20
Reverse polarity protection •
Short-circuit protection •
Overload protection •
Protection IP 65 / IP 66 / IP 67 / IP 68 / IP 69K
Protection class II
Ambient temperature [°C] -40...85
Housing materialsbrass
anti-spatter, sensing face LCP
Switching status indication [LED] yellow (4 x 90°)
Further technical data
Connection technology
Type Version Ordernumber
Socket, M12,2 m grey, PUR cable EVW001
Socket, M12,5 m grey, PUR cable EVW002
Socket, M12,10 m grey, PUR cable EVW003
Socket, M12,2 m grey, PUR cable EVW004
Socket, M12,5 m grey, PUR cable EVW005
Socket, M12,10 m grey, PUR cable EVW006
For further technical details please visit: www.ifm.com
Accessories
Type Version Ordernumber
M12 mounting sleeve with end stop, anti-spatter E12452
M18 mounting sleeve with end stop, anti-spatter E12453
M30 mounting sleeve with end stop, anti-spatter E12454
M12 washers, anti-spatter E12412
M18 washers, anti-spatter E12413
M30 washers, anti-spatter E12414
655450
M12
x1
M12
x1
174
LED 4 x 90°
65
50
244
54
LED 4 x 90°
M18
x1
M12
x1
65
5054
M12
x1
36
M30
x1,5
5LED 4 x 90°
10
Capacitive touch sensors incompact M22 design
Functions and technologyCapacitive touch sensors can be used, for example, asstart and stop function on machines, as enable switchand for opening and closing gates. Compared to mechanical switches the sensors operate without wear.Dynamic touch sensors detect an approaching humanhand and suppress interference such as water, layers of ice or foreign bodies to a large extent. However, agloved hand will still trigger them.Static touch sensors detect hands and objects eventhrough glass for as long as the sensing face is coveredwhich provides, for example, protection against vanda-lism. With the latching operating principle it is possibleto switch the sensor on by touching briefly and to switch it off again by touching briefly again. Furthermore, thehousing is resistant to oils and it is also impact andscratch resistant. It offers the protection rating IP 69K.LEDs for optical feedback signal that the sensor hasbeen activated.
Latching, dynamic or static functions selectable
High IP 69K protection rating and widetemperature range -40...85 °C
Symbols on the sensing face can be selected separately
Easy installation into housing with Ø 22.5 mm bore thanks to M22 x 1.5 thread
Wear-free and maintenance-free thanks to switching without any mechanical pressure
Touch sensor – start, stop and acknowledge
Position sensors
11
(04.2015)
Operating voltage [V DC] 24 (12...30)
Current consumption [mA] 30
Ambient temperature [°C] -40...85
Common technical data
Capacitive sensors
Mounting optionsThe sensor can be installed in all housings with a Ø 22.5 mm hole. The supplied lock nut is used for fixing.Thanks to the M22 thread the sensor can be used for screw mounting without lock nut. Installationalignment of the sensor is not necessary since the clipshowing the symbol for the sensing face is snappedin as the last step.Wiring is done via the tried-and-tested 3- or 4-wire technology.
Position sensors
Connection Current rating
[mA]
Protection Orderno.
Output function NO · DC PNP
Housing material
dynamic 0.3 m PUR cable with M12 plug 200IP 65, IP 67, IP 69K KT5102M22 PA
static 0.3 m PUR cable with M12 plug 200IP 65, IP 67, IP 69K KT5106M22 PA
latching 2 m PUR cable 200IP 65, IP 67, IP 69K KT5150M22 PA
latching 0.3 m PUR cable with M12 plug 200IP 65, IP 67, IP 69K KT5151M22 PA
latching 2 m PUR cable 200IP 65, IP 67, IP 69K KT5350M22 Stainless steel
latching 0.3 m PUR cable with M12 plug 200IP 65, IP 67, IP 69K KT5351M22 Stainless steel
Type Evaluation principle
Accessories
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Symbol disc must be ordered separately
For further technical data please go to: www.ifm.com
Connection technology
Type Description Orderno.
Symbol disc, lettering: START E12377
Symbol disc, lettering: STOP E12378
Symbol disc,symbol: on E12379
Symbol disc,symbol: off E12380
Symbol disc,transparent E12386
Type Description Order no.
Plastic housing, 24 V DC, 2.5 A DN1031
Power supplies
Output function NO · DC PNP · LED can be controlled separately
Type Description Order no.
static 2 m PUR cable 200IP 65, IP 67, IP 69K KT5110M22 PA
dynamic 2 m PUR cable 200IP 65, IP 67, IP 69K KT5111M22 PA
dynamic 0.3 m PUR cable with M12 plug 200IP 65, IP 67, IP 69K KT5112M22 PA
dynamic 2 m PUR cable 200IP 65, IP 67, IP 69K KT5309M22 Stainless steel
static 2 m PUR cable 200IP 65, IP 67, IP 69K KT5310M22 Stainless steel
12
Sensors for pressure up to500 bar for steel detection
Operating principleThe new operating principle is based on a magnetic-inductive technology that detects only ferromagneticmetals (e.g. tool steel). The sensor is flush-mountable.Even in case of overflush installation the sensor detectsthe steel target and shows reliable switching behaviourwith a sensing range of 1.8 mm. A sealing ring and a supporting ring are used for sealing against the pressure zone.
Application examplesBesides use as a limit switch in hydraulic cylinders, thesensor can also be used on other hydraulic componentssuch as valves or pumps. Furthermore, it is used in mechanical engineering processes, e.g. in plastic injection-moulding or process industry applications. The newMFH and M9H series sensors offer an impressive perfor-mance at an attractive price.
Metal sensing face for heavy duty
High burst pressure of 2,000 bar for theM12 housing
Standard M12 and M14 housing types
Best performance at an attractive price
Resistant: withstands 10 million pressure cycles
New pressure-resistant position sensors
Position sensors
13
(04.2015)
M12
x1
101527,8
417
M12
x19,
7
7,8
60
Magnetic sensorsPosition sensors
For further technical details please visit: www.ifm.com
Connection technology
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable, LED EVC008
Cable socket, M12, shielded, 120 °C5 m black, PUR cable E12339
Cable socket, M12, shielded, 120 °C10 m black, PUR cable E12340
Type Sensingrange[mm]
Total length
[mm]
f
[Hz]
OutputAmbienttemperature
[°C]
Orderno.
Operating principle: magnetically biased
M12 1.8 f93 1000 PNP, normally open-25...120
M12 1.8 f93 1000 NPN, normally open-25...120
M12 1.8 f60 1000 PNP, normally open-25...120
M12 1.8 f60 1000 NPN, normally open-25...120
M12 1.8 f60 1000 PNP, normally closed-25...120
M14 1.8 f53 1000 PNP, normally open-25...85
Operating voltage [V] 10...36 DC
Current rating [mA] 200
Short-circuit protection, pulsed •
Reverse polarity / overload protection • / •
Protection rating, protection class
IP 65 / IP 68 / IP 69K,III
Connection M12 connector
Housing material stainless steel 316L / 1.4404
Common technical data
Power supplies
Type Description Orderno.
Plastic housing, 24 V DC, 2.5 A DN1031
Metal housing, 24 V DC, 3.3 A DN4011
Dimensions
Example MFH202
L+
L
1
4
3
Wiring diagram
L+
L
1
2
3
Two designs for many different requirementsThe MFH with its standard M12 housing can be installed and adjusted on many different hydraulic cylinders.That is why most cylinder types are covered by only onesensor.Due to its end stop the M9H allows quick mounting.The processing / installation time is reduced if alwaysthe same cylinder type is used.
MFH200
MFH201
MFH202
MFH203
MFH204
M9H200
14
Photoelectric sensor for usewith coolants / oils
The optimum choice in metalworkingThe new high-performance O6 coolant sensors areespecially suited for applications in metal working. Other applications are conveyor technology and the automotive industry.The potentiometers are fitted with a double seal. The front pane is embedded flush. Viton which is proven in demanding applications was chosen as thesealing material. The transparent black housing coverensures that, even in bright lighting conditions, theLEDs are highly visible.
Best optical performanceThe diffuse reflection sensors provide reliable back-ground suppression, even in cases of highly reflectivebackgrounds and objects like the oily and greasy metalsurfaces of the parts to be worked. The sensing rangeis independent of the type and colour of the object tobe detected. The new O6 coolant reliably performs its duty in applications with coolants / oils.
Long life due to resistant materials
Diffuse reflection sensor with reliablebackground suppression
Range is independent of the object colour
Design with 4-pole M8 connector
Stainless steel housing with protection rating IP 68 / IP 69K
When oil is all over – The new O6 coolant
Position sensors
15
(11.2015)
Infrared sensors / red light sensorsPosition sensors
For further technical details please visit: www.ifm.com
Diffuse reflection sensor with background suppression · 3-wire DC
Spotdiameter
[mm]
ConnectionM8 connector
8*
Range
[mm]
2...200 4-pole
Current consumption
[mA]
22
Diffuse reflection sensor · 3-wire DC
15*5...500 4-pole 16
Retro-reflective sensor with polarisation filter · 3-wire DC
150**50...5000 4-pole 12
Through-beam sensor – transmitter · 2-wire DC
300*0...10000 4-pole 11
Through-beam sensor – receiver · 3-wire DC
–0...10000 4-pole 7
Type of light,wave length
[nm]
Red light, 633
Red light, 633
Red light, 645
Red light, 645
Red light, 645
* at maximum range, ** referred to prismatic reflector Ø 80 mm
Accessories
Type Description Orderno.
Common technical data
Operating voltage [V DC] 10...30
Switching status indication LED Yellow
Operation LED Green
Short-circuit protection, pulsed •
Reverse polarity protection / overload protection • / •
Ambient temperature [°C] -25...60
Voltage drop [V] < 2.5
Current rating [mA] 100
Materials Housing
LensSeal
High-grade stainless steel(316L/1.4404), PPSU
PMMAFKM
Switching frequency [Hz] 1000
Protection rating, protection class
IP 65, IP 67, IP 68, IP 69 K,III
O6H400O6H401
Orderno.
Orderno.
PNPNPN
O6T400O6T401
PNPNPN
O6P400O6P401
PNPNPN
O6S400
O6E400O6E401
PNPNPN
Angle bracket for free-standing mounting, stainless steel E21271
Protective bracket, stainless steel E21273
Mounting accessories
Plastic housing, 24 V DC, 2.5 A DN1031
Metal housing, 24 V DC, 3.3 A DN4011
Power supplies
Connection technology
Type Description Orderno.
Socket, M8, 4-pole2 m black, PUR cable EVC150
Socket, M8, 4-pole5 m black, PUR cable EVC151
Socket, M8, 4-pole2 m black, PUR cable EVC153
Socket, M8, 4-pole5 m black, PUR cable EVC154
Ø 50 mm, plastic E20956
Ø 80 mm, plastic E20005
48 x 48 mm, PMMA, ABS E20744
95 x 95 mm, plastic E20454
Prismatic reflectors
Mounting set for clamp mounting, stainless steel, Ø 10 mm E21272
Mounting set for clamp mounting, stainless steel, Ø 12 mm E21275
Rod, 120 mm, Ø 10 mm, M8 thread, stainless steel E21081
Rod, 100 mm, Ø 12 mm, M10 thread, stainless steel E20938
16
Powerful photoelectric sensors in a plastic housing
Ideal for universal applicationsWhether in different types of access controls such asgate applications in airports or with escalators, – wherever people are to be detected, visible light is often not wanted. In such applications especially photoelectric sensors with non-visible infrared light find a wide rangeof applications.
Best optical performanceInfrared light allows longer ranges, in particular withdark (black) objects. In addition, the products featurehigh extraneous light immunity. Besides energetic diffuse reflection sensors the units are also available as through-beam sensors. All models are equipped with a 4-pole M8 connector.The sensors are distinguished by an excellent price /performance ratio. Extensive mounting accessoriescomplete the range.
Precise detection with non-visible infrared light
Increased operational safety in steam, fog and dust
Easy setting via potentiometer or rotaryswitch
In particular suitable for gate applications
Not only available as energetic diffuse reflection sensor but also as through-beam sensor
The new compact O6 photoelectric sensors with infrared light
Position sensors
17
(04.2015)
Infrared sensors / red light sensors
Diffuse reflection sensor · 3-wire DC
Light spot diameter
[mm]
Connection Orderno.
15* O6T215
Range
[mm]
5...600 mm M8 connector,4-pole
Orderno.
O6T216
Position sensors
PNPNPN
Through-beam sensor - transmitter · 2-wire DC
300*0...15 m M8 connector,4-pole O6S215
Through-beam sensor – receiver · 3-wire DC
– O6E2150...15 m M8 connector,4-pole O6E216
PNPNPN
* at maximum range
Light-on / dark-on mode
• / •adjustable
– / –
• / •adjustable
For further technical details please visit: www.ifm.com
Accessories
Type Description Orderno.
Mounting set for clamp mounting, stainless steel, Ø 10 mm E21272
Mounting set for clamp mounting, stainless steel, Ø 12 mm E21275
Angle bracket for free-standing mounting, stainless steel E21271
Protective bracket, stainless steel E21273
Rod, 120 mm, Ø 10 mm, M8 thread, stainless steel E21081
Rod, 100 mm, Ø 12 mm, M10 thread, stainless steel E20938
Cube for mounting on an aluminiumprofile, M8 thread, diecast zinc E20950
Cube for mounting on an aluminiumprofile, M10 thread, diecast zinc E20951
Mounting accessories
Common technical data
Operating voltage [V DC] 10...30
Type of light Infrared light 850 nm
Switching status indication LED Yellow
Switching frequency [Hz] 1000
Protection rating, protection class
IP 65 / IP 67,III
Indication stable operation LED Green
Short-circuit protection, pulsed •
Reverse polarity protection / Overload protection • / •
Ambient temperature [°C] -25...60
Voltage drop [V] < 2.5
Current rating [mA] 100
Materials Housing
Lens
ABS
PMMA
Connection technology
Type Description Orderno.
Socket, M8, 4-pole2 m black, PUR cable EVC150
Socket, M8, 4-pole5 m black, PUR cable EVC151
Socket, M8, 4-pole2 m black, PUR cable EVC153
Socket, M8, 4-pole5 m black, PUR cable EVC154
Plastic housing, 24 V DC, 2.5 A DN1031
Metal housing, 24 V DC, 3.3 A DN4011
Power supplies
18
Small and compact photoelectric sensors nowalso as IO-Link versions!
Best performanceThe diffuse reflection sensors distinguish themselves byreliable background suppression, even in case of highlyreflective backgrounds. A special feature is the automatic switch point adjustment that guarantees reliable operation even in steam, smoke or highly reflective environments. The WetLine series features a particularly robust stain-less steel housing with protection rating IP 68 / IP 69K. The potentiometer with double sealing ensures maximum ingress resistance. The flush front lens ensures cleaningwithout residues.
IO-LinkThe O6 WetLine sensors are now also available as versions with IO-Link. Via this interface, the user can set range,sensitivity, light-on / dark-on mode, switching delay ordeactivation of the operating elements.
Stainless steel housing with protection rating IP 68 / IP 69K
Diffuse reflection sensors with reliablebackground suppression
Well-defined light spot for precise objectdetection, no scattered light
Also available as through-beam or retro-reflective system
Many functions can be set via IO-Link,e.g. range and sensitivity
O6 WetLine now with IO-Link!
Position sensors
19
(11.2014)
Infrared sensors / red light sensorsPosition sensors
For further technical details please visit: www.ifm.com
Diffuse reflection sensor with background suppression · 3-wire DC · PNP
Light spot diameter
[mm]
Connection M8 connector
Order no.
8* O6H309
Range
[mm]
2...200 4-pole
Current consumption
[mA]
22
Diffuse reflection sensor · 3-wire DC · PNP
15* O6T3095...500 4-pole 16
Retro-reflective sensor with polarisation filter · 3-wire DC · PNP
150** O6P30950...5000 4-pole 12
Through-beam sensor - transmitter · 2-wire DC
300*0...10000 4-pole 11 O6S305
Through-beam sensor – receiver · 3-wire DC · PNP
– O6E3090...10000 4-pole 7
Communication interface
IO-Link 1.1
IO-Link 1.1
IO-Link 1.1
IO-Link 1.1
IO-Link 1.1
* at maximum range** referred to prismatic reflector Ø 80 mm
Accessories
Type Description Order no.
Mounting set for clamp mounting, stainless steel, Ø 10 mm E21272
Angle bracket for free-standing mounting, stainless steel E21271
Rod, 120 mm, Ø 10 mm, M8 thread, stainless steel E21081
Memory plug, parameter memoryfor IO-Link sensors E30398
IO-Link interface, current consumptionfrom USB port E30396
LINERECORDER SENSOR,software for parameter setting and set-up of IO-Link sensors
QA0001
Common technical data
Operating voltage [V DC] 10...30
Type of light red light 633 nm
Switching status indication LED yellow
Operation LED green
Short-circuit protection, pulsed •
Reverse polarity protection / overload protection • / •
Ambient temperature [°C] -25...80
Voltage drop [V] < 2.5
Current rating [mA] 100
Materials housing
lens
high-grade stainless steel(316L/1.4404), PPSU
PMMA
Connection technology
Type Description Order no.
M8 socket, 4-pole,2 m orange, PVC cable
M8 socket, 4-pole,5 m orange, PVC cable
M8 socket, 4-pole,2 m orange, PVC cable
M8 socket, 4-pole,5 m orange, PVC cable
Adapter cable M12 plug to M8 socket 4-pole, 0.3 m orange, PVC cable
EVT248
Switching frequency [Hz] 1000
Protection rating, protection class
IP 65, IP 67, IP 68, IP 69K,III
Light-on / dark-on mode adjustable
18 x 18 mm, Solidchem plastic E21267
56 x 38 mm, Solidchem plastic E21268
48 x 48 mm, Solidchem plastic E21269
96 x 96 mm, Solidchem plastic E21270
EVT134
EVT135
EVT138
EVT139
20
PMD O5D – Now also withlaser class 1
Time of flight measurement for standard sensorsThe O5D with time of flight measurement (PMD = photonic mixer device) combines the advantages oflong range, reliable background suppression, visible redlight, high excess gain and laser class 1.This makes it a clever alternative to standard sensors,which are equal in price and size.
Easy handlingThe switch point is easily and precisely set via “+/-” buttons and display or IO-Link, which also allows read-out of the actual value.
Any surface and any mounting positionShiny, matt, dark or light objects of any colour: the O5D features reliable background suppression. The unitallows any angle of incidence of the transmitted lightand thus any mounting position.
Precise time of flight measurement (PMD)in a compact housing
Reliable background suppression and colour-independent detection
Shiny surfaces are detected reliably (e.g. stainless steel)
Switch point setting to the nearest centimetre via “+/-” buttons and display
Laser class 1 – for more universal application
First class PMDLine!
Position sensors
21
(11.2014)
For further technical data please go to: www.ifm.com
Laser sensors / distance measurement sensors
Common technical data
Operating voltage [V DC] 10...30
Dimensions [mm] 56 x 18,2 x 46,5
Type of light visible laser light 650 nm
Extraneous light on the object [klx] max. 8
Switching status indication LED yellow
Operation LED green
Distance value3-digit
alphanumeric display
Protection rating, protection class
IP 65,IP 67III
Short-circuit protection, pulsed •
Reverse polarity protection / overload protection • / •
Ambient temperature [°C] -25...60
Current rating [mA] 2 x 100
Output function OUT1: NOOUT2: NC
Position sensors
Connection technology
Type Description Order no.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Photoelectric distance sensor, laser protection class 1 · M12 connector, complementary
Material housing / plug adapterfront pane / LED window
bezeloperator interface
PAPMMA
stainless steelTPU
Accessories
Type Description Order no.
Mounting bracket for rod,complete set incl. clamp E21083
Protective bracket for rod,complete set incl. clamp E21084
Bracket for free-standing mounting E21087
Dovetail clamp E21088
Rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938
Cube for mounting on an aluminiumprofile, M10 thread, diecast zinc E20951
Measuringrange[mm]
Backgroundsuppression
[m]
Switching frequency
[Hz]
Spot Ø at max. range
[mm]
Current consumption
[mA]
Order no.
Unit of measurement
Hysteresis
[%]
Memory plug, parameter memory for IO-Link sensors E30398
IO-Link interface, current consumption from USB port E30396
LINERECORDER SENSOR, software for parameter setting and set-up of IO-Link sensors
QA0001
* in case of max. range
Metal housing, 24 V DC, 3.3 A DN4011
Power supplies
Type Description Order no.
30...2000 ...20 11 < 5 < 75 O5D151
30...2000 ...20 O5D15011 < 5 < 75 cm
inch< 7.5*
< 7.5*
PNP
22
Photoelectric sensor with time of flight measurement (PMD),easy-turn concept, laser class 1
Time of flight measurement for standard sensorsThe OID with time of flight measurement (PMD = photonic mixer device) combines the following advan-tages: long ranges, reliable background suppression, visible red light, high excess gain and now also laserclass 1. In the same price range as standard sensors, it is a clever alternative.
Easy handlingThe switch point can be set easily by turning the settingring (easy turn, lock function). A scale shows the distance set. The switch point can thus be set before installation.
Any surface and any mounting positionShiny, matt, dark or light objects of any colour: the OID features reliable background suppression. The unit allows any angle of incidence and thus flexible mountingpositions. This simplifies installation and saves costs.
Reliable background suppression and colour-independent detection
Simple switch point setting by rotatablesetting ring (lock function)
Shiny surfaces are detected reliably (e.g. stainless steel)
Any sensor position, even an obliqueangle to the object
Laser class 1 – for more universal application
PMDLine M30: Now also with laser class 1
Position sensors
23
(11.2014)
For further technical data please go to: www.ifm.com
Laser sensors / distance measurement sensors
Common technical data
Operating voltage [V DC] 10...30
Dimensions M30 x 90 mm
Type of light visible laser light 650 nm
Extraneous light on the object [klx] max. 8
Switching status indication LED yellow
Operation LED green
Switch point (setting) radial setting ring
Protection rating, protection class
IP 65,IP 67III
Short-circuit protection, pulsed •
Reverse polarity protection / overload protection • / •
Ambient temperature [°C] -25...60
Current rating [mA] 2 x 100
Output function OUT1: NOOUT2: NC
Position sensors
Connection technology
Type Description Order no.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Photoelectric distance sensor, laser protection class 1 · M12 connector, complementary
Measuringrange[mm]
Backgroundsuppression
[m]
Switching frequency
[Hz]
Spot Ø at max. range
[mm]
Current consumption
[mA]
Order no.
Unit of measurement
Hysteresis
[%]
Material housing
front pane
stainless steel, PBT, PC, FPM
PMMA
Rod, 100 mm, Ø 12 mm,M10 thread, stainless steel E20938
Cube for mounting on an aluminiumprofile, M10 thread, diecast zinc E20951
Type Description Order no.
Accessories
Angle bracket for type M30,stainless steel E10737
Mounting clamp for types M30, PTB E10077
Mounting set Ø 30.2 mm, clamp mounting, aluminium profile E20875
Mounting set Ø 30.2 mm, clamp mounting E20873
Mounting set Ø 30.2 mm, clamp mounting, high-grade stainless steel E20874
Mounting clamp, with end stop for types M30, PC E11049
Memory plug, parameter memory for IO-Link sensors E30398
IO-Link interface, current consumption from USB port E30396
LINERECORDER SENSOR, software for parameter setting and set-up of IO-Link sensors
QA0001
* in case of max. range
Metal housing, 24 V DC, 3.3 A DN4011
Power supplies
Type Description Order no.
30...2000 ...20 11 < 5 < 75 OID251
30...2000 ...20 OID25011
< 5*
< 5* < 5 < 75 cm / inch
cm
PNP
24
Photoelectric sensor withPMD technology, easily andquickly configurable
Time of flight technology as standard sensorThe OID with time of flight technology (PMD = Photonic Mixer Device) combines the following advantages: Long range, reliable background suppression, visiblered light, high excess gain and all that also combinedwith either laser class 1 or 2. In the same price range as standard sensors, it is a clever alternative.
IO-Link for easy parameter settingThe switch point can be easily set via a controller or aPC. Unintentional maladjustment directly on the sensoris thus excluded and increases the protection againsttampering. The laser beam can be switched off via IO-Link or pin 5 on the M12 connector.
Any surface and any mounting positionShiny, matt, dark or light objects of any colour: The OID features reliable background suppression andallows any angle of incidence and thus flexible mounting positions. This simplifies installation and saves costs.
Compact housing length of only 70mm
Convenient setting of all parameters via IO-Link 1.1
Long range of 30 mm up to 2,000 mm
High protection rating IP 69K enables applications with high requirements
Versions with laser protection class 1 or 2available
PMDLine M30 compact: time offlight technology and IO-Link
Position sensors
25
(04.2015)
Laser sensors / distance measurement sensors
Common technical data
Operating voltage [V DC] 10...30
Dimensions M30 x 70 mm
Type of light
Visible laser light 650 Nm,
can be switched off via pin 5 or IO-Link
Extraneous light on the object [klx] Max. 8
Switching status indication LED Yellow
Switch point (set) via IO-Link 1.1
Protection rating, protection class
IP 65, IP 67, IP 68, IP 69KIII
Short-circuit protection, pulsed •
Reverse polarity protection / overload protection • / •
Ambient temperature [°C] -25...60
Current rating [mA] 2 x 100
Output function OUT1: NOOUT2: NC
For further technical details please visit: www.ifm.com
Position sensors
Connection technology
Type Description Orderno.
Socket, M12, 5-pole,2 m black, PUR cable EVC073
Socket, M12, 5-pole,5 m black, PUR cable EVC074
Socket, M12, 5-pole,5 m black, PVC cable EVT013
Photoelectric distance sensor · M12 connector, complementary
Measuringrange[mm]
Backgroundsuppression
[m]
Switching frequency
[Hz]
Spot Ø atmax. range
[mm]
Current consumption
[mA]
Orderno.
30...2000 ...20 11 < 5 < 75 OID254
Laser protection
class
30...2000 ...20 OID20411
Hysteresis
[%]
< 2.5...5*
< 1.5...3* < 5 < 75 2
1
Material HousingFront pane
Stainless steelPMMA
Cube for mounting on an aluminiumprofile, M10 thread, diecast zinc E20951
Type Description Orderno.
Accessories
Angle bracket for type M30,stainless steel E10737
Mounting clamp for types M30, PTB E10077
Mounting clamp, with end stop for types M30, PC
E11049
Memory plug, parameter memoryfor IO-Link sensors E30398
IO-Link interface, current consumption from USB port E30396
LINERECORDER SENSOR,software for parameter setting and setting up IO-Link sensors
QA0001
* at max. range
PNP
Hysteresis
500 1000 1500 200000
25
50
75
100
125
150
175
200
y
x
2 b
1 b2 a
1 a
x: Distance in [mm], y: Hysteresis in [mm]1. Background black (6 % remission)2. Background white (90 % remission)
Laser protection class 1Laser protection class 2
26
Sensors for motion control
Motion controller: Encoder,speed / direction monitorand counter all in one
No compromisesThe magnetic sensing principle provides the accuracy ofphotoelectric encoders and the robustness of magneticsystems.
SimpleResolution and signal level can be programmed. Theencoders have a wide voltage range of 4.5...30 V DCand are therefore suited for universal use.
MultifunctionalPerformance Line encoders have an integrated signalevaluation for speed monitoring, counter functionsand detection of the direction of rotation.
IntuitiveThe encoders provide easy setting, position indicationby means of display and operating keys and intuitivemenu navigation.
NetworkedDiagnostic and parameter data are reliably transferredvia IO-Link. Ready for Industry 4.0.
Resolution of 2...10,000 and signal level(TTL / HTL) freely programmable
Display: Two-colour electronic rotatabledisplay of the process values
Versatile: M12 connector can be usedradially or axially
Standard fitting: Solid shaft (clamp /synchro flange) or hollow shaft design
Transmission of process and diagnosticdata via IO-Link
Intelligent incremental encoderwith display and IO-Link
27
(04.2015)
Encoders
For further technical details please visit: www.ifm.com
Sensors for motion control
Flange IO-LinkResolution
[pulse/revolution]
Orderno.
Hollow shaft with integrated stator coupling· 4-digit display · Integrated pulse evaluation
direct •max. 10,000 (adjustable) ROP52012
Operating voltage
[V DC]
4.5...30
Shaft Ø
[mm]
Solid shaft · 4-digit display · Integrated pulse evaluation
servo •max. 10,000 (adjustable) RUP5006 4.5...30
clamp flange •max. 10,000 (adjustable) RVP51010 4.5...30
Protection IP 65, IP 67
Connection M12 connector (rotatable)
Further technical data
58
58
58
Housing Ø
[mm]
Switching frequency [kHz] 300
Accessories
Type Description Orderno.
Spring disc coupling, Ø 6 mm / 10 mm, die-cast zinc; PA E60117
Spring disc coupling, Ø 10 mm / 10 mm, die-cast zinc; PA E60118
Flexible coupling with clamp connection,Ø 6 mm / 10 mm, aluminium E60066
Flexible coupling with clamp connection,Ø 10 mm / 10 mm, aluminium E60067
Flexible coupling with adjusting screws,Ø 10 mm / 10 mm, aluminium E60022
Flexible coupling with adjusting screws,Ø 6 mm / 10 mm, aluminium E60028
Measuring wheel, Ø 159.15 mm / 10 mm, Hytrel TPE-E E60110
Measuring wheel, Ø 159.16 mm / 10 mm, aluminium, PU E60076
Measuring wheel, Ø 63.66 ± 0.1 mm / 10 mm, Hytrel TPE-E E60138
Measuring wheel, Ø 63.6 mm, 10 mm, aluminium E60095
Measuring wheel, Ø 63.66 ± 0.1 mm / 6 mm, aluminium E60137
Measuring wheel, Ø 63.6 mm, 6 mm, aluminium E60006
Angle bracket for RUP design,aluminium, black anodised E60033
Angle bracket for RUP design,aluminium, black anodised E60035
Fastening clamp for synchro flange, steel E60041
Memory plug, parameter memoryfor IO-Link sensors E30398
LINERECORDER SENSOR,Software for parameter setting and set-up of IO-Link sensors
QA0001
Accessories
Type Description Orderno.
Connection technology
Type Description Orderno.
M12 socket, shielded,5 m black , PUR cable, 8 poles E12403
M12 socket, shielded,10 m black , PUR cable, 8 poles E12404
M12 socket, shielded,2 m black , PUR cable, 8 poles E12402
USB IO-Link master for parameter settingand analysis of unitsSupported communication protocols:IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
Adapter cable for the connectionbetween USB IO-Link master E30390and 4-pole / 8-pole encoder
E12432
28
Reduce stock withoutcompromise
No compromises
The magnetic sensing principle provides the accuracy ofphotoelectric encoders and the robustness of magneticsystems.
Select the right encoder in just 2 minutesThe days of confusing type variety and encoders withcomplicated programming are finally over! The new incremental encoders from ifm electronic can be useduniversally due to the intelligent product and functiondesign, and stand out thanks to a superb price /performance ratio:• Set the resolution individually• Choose between TTL or HTL logic• Use the rotatable M12 connector or the cable entry
radially or axiallyNow select a flange and shaft – that’s it!
IO-Link communicationProcess values, parameter setting and diagnostic datacan now be transmitted via IO-Link. So, settings can besimply made prior to installation.
Flexible: Resolution of 2...10,000 freelyprogrammable
Simple: Signal level can be set in TTLor HTL logic
Universal: M12 connector or radial oraxial cable entry
Standard fitting: Solid shaft (clamp / synchro flange) or hollow shaft design
Communicative: Transfer of processand diagnostic data via IO-Link
Programmable incrementalencoder with IO-Link
Sensors for motion control
29
(04.2015)
Encoders
For further technical details please visit: www.ifm.com
Accessories
Type Description Orderno.
Spring disc coupling, Ø 6 mm / 10 mm, die-cast zinc; PA E60117
Spring disc coupling, Ø 10 mm / 10 mm, die-cast zinc; PA E60118
Flexible coupling with clamp connection,Ø 6 mm / 10 mm, aluminium E60066
Flexible coupling with clamp connection,Ø 10 mm / 10 mm, aluminium E60067
Flexible coupling with adjusting screws,Ø 10 mm / 10 mm, aluminium E60022
Flexible coupling with adjusting screws,Ø 6 mm / 10 mm, aluminium E60028
Measuring wheel, Ø 159.15 mm / 10 mm, Hytrel TPE-E E60110
Measuring wheel, Ø 159.16 mm / 10 mm, aluminium, PU E60076
Measuring wheel, Ø 63.66 ± 0.1 mm / 10 mm, Hytrel TPE-E E60138
Measuring wheel, Ø 63.6 mm, 10 mm, aluminium E60095
Measuring wheel, Ø 63.66 ± 0.1 mm / 6 mm, aluminium E60137
Measuring wheel, Ø 63.6 mm, 6 mm, aluminium E60006
Sensors for motion control
Flange IO-LinkResolution
[pulse/revolution]
Orderno.
Hollow shaft with integrated stator coupling
direct •max. 10,000 (adjustable) RA31006
Connection
M12
direct •max. 10,000 (adjustable) RA35006 cable, 2 m
direct •max. 10,000 (adjustable) RO310012 M12
direct •max. 10,000 (adjustable) RO350012 cable, 2 m
Shaft Ø
[mm]
Solid shaft
universal •max. 10,000 (adjustable) RB31006 M12
universal •max. 10,000 (adjustable) RB35006 cable, 2 m
servo •max. 10,000 (adjustable) RU31006 M12
servo •max. 10,000 (adjustable) RU35006 cable, 2 m
clamp flange •max. 10,000 (adjustable) RV310010 M12
clamp flange •max. 10,000 (adjustable) RV350010
36.5
36.5
58
58
Housing Ø
[mm]
36.5
36.5
58
58
58
58 cable, 2 m
Angle bracket for RB and RU design,aluminium, black anodised E60033
Angle bracket for RV design,aluminium, black anodised E60035
Switching frequency [kHz] 300
Operating voltage [V DC] 4.5...30
Protection IP 65, IP 67
Further technical data
Memory plug, parameter memoryfor IO-Link sensors E30398
LINERECORDER SENSOR,software for parameter setting and set-up of IO-Link sensors
QA0001
Accessories
Type Description Orderno.Fastening clamp for
synchro flange, steel E60041
USB IO-Link master for parameter settingand analysis of unitsSupported communication protocols:IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
Connection technology
Type Description Orderno.
M12 socket, shielded,5 m black, PUR cable, 5 poles EVC545
M12 socket, shielded,10 m black, PUR cable, 5 poles EVC546
M12 socket, shielded,2 m black, PUR cable, 5 poles EVC544
30
With analogue and switchingoutputs as well as vibrationmonitoring
Precision countsThe 2-axis inclination sensors are designed for highmeasurement accuracies over the whole angular range.All functions can be configured via IO-Link.Thanks to an active temperature compensation and highprotection rating they operate reliably even at extremeambient temperatures and rough environments.
Vibration monitoringAlternatively, JN2200 can also be used for 3-axis vibra-tion monitoring. Up to 3 axes can be included into thecalculation of the characteristic value.Typical applications are the detection of structural vibration or tower vibration to ISO 4866, or machinemonitoring to ISO 10816.
High accuracy across the whole 2-axisangular range up to 360°
Very low temperature drift due to activetemperature compensation
Visualisation of the operating andswitching states by clearly visible LEDs
Configurable current and voltage outputfunctions
Adjustable filter functions for differentapplications.
Robust and precise inclinationsensors – Now with IO-Link
Sensors for motion control
31
(11.2015)
9075
224562
5,3
364,
5
Operating voltage [V DC]with:Switching and current outputsVoltage outputIO-Link connection
9.2...3012...3018...30
Reverse polarity protection •
Angular rangeAbsolute accuracyRepeatabilityResolution
JN2200±180°/± 90°
≤ ± 0.5°≤ ± 0.1°≤ ± 0.05°
JN2201± 45°
≤ ± 0.1°≤ ± 0.05°≤ ± 0.01°
Ambient temperature [°C] -40...85
Temperature coefficient [°/K] ≤ ± 0.002
Protection rating IP 65 / IP 67 / IP 68 / IP 69K
Number of measurement axes with inclination 2
Frequency range [Hz] 0.1...400
Measuring range [g] ± 2, ± 4, ± 8
2
0.5...50
± 2
Number of measurement axes with vibration 3 –
Housing material diecast zinc nickel-plated
Connection2 x
M12 connector(4 poles; A-coded)
Technical dataJN2200, JN2201
Inclination sensors
Connection technology
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVM039
Socket, M12,10 m black, PUR cable EVM041
Socket, M12,2 m black, PUR cable EVM036
Socket, M12,10 m black, PUR cable EVM038
Jumper, M12,5 m black, PUR cable EVC069
Jumper, M12,5 m black, PUR cable EVC059
Accessories
Description Orderno.
Dimensions
Type
For further technical details please visit: www.ifm.com
Sensors for motion control
The products
Description Orderno.
Angular range ± 180° / ± 90°,IO-Link JN2200
Angular range ± 45°,IO-Link JN2201
Type
Communication interfaceIO-Link 1.1,
COM 2,38.4 kbaud
LINERECORDER SENSORSoftware for parameter setting and set-up of IO-Link sensors
QA0001
USB IO-Link master for parameter settingand analysis of unitsSupported communication protocols: IO-Link (4.8, 38.4 and 230 kBit/s)
E30390
Memory plug, parameter memoryfor IO-Link sensors E30398
32
2-axis inclination measurement and 3-axis vibration monitoring
Precise in all positionsThe new ifm type JN inclination sensors provide highmeasurement accuracy across the whole angular rangewith angles of inclination in X and Y axes. The 2-axis inclination sensors with CANopen interfaceand bus capability are designed for levelling of mobilemachinery (2-axis position detection and zero-point levelling for mobile applications) or automatic adjustment of solar panels, for example.
Vibration monitoringAlternatively, JN2100/JN2300 can also be used for 3-axis vibration monitoring. Up to 3 axes can be included intothe calculation of the characteristic value. Typical applications are the detection of structural vibration or tower vibration to ISO 4866, or machinemonitoring to ISO 10816.
High precision across the total angularrange in two axes
Zero point, counting direction and limitfrequency adjustable
Active temperature compensation(very low temperature drift)
Vibration monitoring in 3 axes (only JN2100/JN2300)
Full CAN integration possible, CAN-In and CAN-Out
Precision for all inclinations
Sensors for motion control
33
(11.2014)
Operating voltage [V DC] 9.2...30
Reverse polarity protection •
Angular rangeResolutionRepeatability
JN2100JN2300± 180°0.05°
≤ ± 0.1°
JN2101JN2301± 45°0.01°
≤ ± 0.05°
Ambient temperature [°C]
Temperature coefficient [°/K] ≤ ± 0.002°
Protection IP 65 / IP 67 / IP 68 / IP 69K
Data interface
CANopen Device profile CiA DSP-410 /
SAE J1939
Limit frequency inclination [Hz] adjustable: 10, 5, 1, 0.5
Filter for [Hz]vibration monitoring
0.1...1, 0.1...10, 1...10,2...400, 10...400
Housing material Diecast zinc nickel-plated
Connection 2 x M12 connector
Technical dataJN2100, JN2101,JN2300, JN2301
Inclination sensors
Connection technology
Type Description Order no.
Socket, M12,2 m black, PUR cable EVM039
Socket, M12,10 m black, PUR cable EVM041
Socket, M12,2 m black, PUR cable EVM036
Socket, M12,10 m black, PUR cable EVM038
Accessories
Description Order no.
Adapter cable for CAN devices with M12 connector (5 pole) EC2062
Dimensions
364,
5
9075
224560
5,3
Flexible, precise, reliableSince zero point, direction of counting and limit frequency can be set for a stable output signal, thesensors can be adapted precisely to your application.Very low temperature drift across the whole tempera-ture range provides unrivalled reliability.
Ideal for different applicationsThe sensors allow complete CAN integration according to the CANopen communication profiles,CiA DSP-410 and CiA DS-301 profiles.They are connected via an M12 connector. The terminating resistor can be enabled. The sensors provide the signals either as perpendicular angle, Euler angle or Gimbal angle.
Type
Sensors for motion control
For further technical details please visit: www.ifm.com
Jumper, M12,5 m, black, PUR cable EVC069
Jumper, M12,5 m, black, PUR cable EVC059
-40...85
Number of measurement axes for inclination 2
Number of measurement axes for vibration 3 –
The products
Description Order no.
Angular range ± 180°,CANopen JN2100
Angular range ± 45°,CANopen JN2101
Angular range ± 180°,SAE J1939 JN2300
Angular range ± 45°,SAE J1939 JN2301
Type
34
Evaluation units for level control with one or twosensors
Favourably priced and effective level control for tanks
ApplicationThe evaluation units control levels in tanks by means of sensors thus protecting against overflow, runningdry and leakage, for example.
Level control with a sensorThe DL0201 evaluation unit uses a sensor that is installed at the tank at the height of the limit level tobe monitored. When the level has been reached, theevaluation unit switches for an adjustable period oftime to stop pumps, for example, as overflow or run-dry protection.
Level control with two sensorsThe DL0203 evaluation unit is a typical 2-point controlthat controls an upper and a lower limit on pumps andvalves by means of two sensors.
Direct control of pumps and valves
Adjustable switch-on and switch-off delaysand damping
Integrated wide-range power supply forthe sensor supply
Small design requiring only very littlespace
Plug-in screw terminals simplify installation
Easy level control
Sensors for motion control
35
(04.2015)
Further technical dataOperating principle DL0201The DL0201 evaluation unit is actually a timer. When itreceives a signal from the connected sensor, it switchesthe relay change-over contact for a certain period oftime. By means of two scaled potentiometers the usercan set the time between 0 and 60 seconds or 0 and60 minutes. Adjustable switch-on and switch-off delaysact as damping. This suppresses brief fluctuationsaround the sensor switch.In addition the evaluation unit has an enable functionby means of which control can be bridged manually. Aleakage sensor can also be integrated into the controlfunction by means of the enable input.
Application exampleThe upper level in a tank is monitored via a capacitivesensor. When the level has been reached, the sensorprovides a signal to the evaluation unit. It closes thesupply valve for the time set to prevent overfilling. Thedamping function prevents, for example, one singlewave generating a switching signal.
Operating principle DL0203It is a typical two-point control. When a sensor providesa signal, the relay change-over contact switches untilthe second sensor provides a signal for switch-off. A switch-on delay is available that acts as damping andsuppresses short-term fluctuations around the sensorswitch point.
Application exampleTo protect a pump against running dry two capacitivesensors are installed on the storage tank. When thelower minimum level has been reached, the sensor provides a signal to the evaluation unit. With the relayoutput it switches off the pump that is normally usedto empty the tank. When the upper level has been reached, the secondsensor installed there switches, the relay in the evaluation unit switches on again and the pump is started.
Systems for pulse evaluationSensors for motion control
Nominal voltage
[V]
Outputs Relays / transistors
Auxiliary energy for sensors
Orderno.
Limit level monitoring (overflow, running dry, leakage)
110...240 AC (50...60 Hz) / 27 DC
(typ. 24 DC)1 / 1
typ. 18.5...30 V DC / ≤ 100 mA
short circuit / overload protected
DL0201
Relay outputs
1 x changeover contact4 A
(240 V AC, 24 V DC); resistive load
Transistor outputs
1 x PNP / externally supplied 10...30 V DC SELV /
≤ 100 mA
Ambient temperature [°C] -25...60
Storage temperature [°C] -25...70
Protection housing / terminals IP 20 / IP 20
Connection4-pole connector
with screw connection, 5.0 mm pitch
For further technical details please visit: www.ifm.com
Type InputsSignal / enable
Inputfrequency
[Hz]
1 x PNP / 1 x PNP(type 2
acc. to IEC 61131-2)≤ 5
Two-point control of levels
110...240 AC (50...60 Hz) / 27 DC
(typ. 24 DC)1 / 1
typ. 18.5...30 V DC / ≤ 100 mA
short circuit / overload protected
DL02032 x PNP / –
(type 2 acc. to IEC 61131-2)
≤ 5
Display DL0201 LEDPower supply
InputOutput
Enable
GreenYellow
Green (lights if relay energised and transistor
switched)Green (lights if
enable signal is present)
Display DL0203 LEDPower supply
InputOutput
Green2 x yellow
Green (lights if relay energised and transistor
switched)
Accessories
Type Description Orderno.
Connector, 4 poles with screw terminals, pack of 5(supplied)
E40173
Connector, 4 poles with cage clamps, pack of 5
E40171
36
Sensors for motion control
Switching amplifier for converting sensor signals inAC networks
Relay for high load currentsThe transistor outputs of conventional sensors are designed for small load currents. If the user wants toswitch higher currents or even alternating currents, he must use a switching amplifier.It uses the sensor signal to control an output relay.
Flexible and space-savingifm offers switching amplifiers in one and two-channeldesign. They have an integrated wide-range power supply (110...240 V AC) to supply the connected sensors with voltage (24 V DC). The new switching amplifiersare distinguished by their slim design so that they onlyneed little space in the control cabinet.
Integrated wide-range power supply for the sensor supply
Small design requiring only very little space
Plug-in screw terminals simplify installation
PNP or NPN control selectable
One or two-channel design
Sensor signals switch relay
37
(04.2015)
25,4 109,1
93
LED s
3
2
4
35,5
112,
6
1
Sensors for motion control
For further technical details please visit: www.ifm.com
Systems for pulse evaluation
Dimensions
DN0220
1) plug-in screw terminals2) panel for labelling3) potentiometer4) DIN rail mounting
Type Ub
[V]
Pulseinput
Inputs Auxiliary energy for sensors
Inputfrequency
[Hz]
Orderno.
Application: power supply and signal evaluation (e.g. for sensors)
110...240 AC50...60 Hz PNP / NPN1 24 V DC,
300 mA≤ 10 DN0210
110...240 AC50...60 Hz PNP / NPN2 24 V DC,
2 x 150 mA≤ 10
OutputsRelay
1
2 DN0220
Relay outputContact rating [A]
4 (240 V AC, 24 V DC); resistive load
Auxiliary energy for sensors [V]
24 DC SELV, ± 10 %, 300 mA,
short-circuit and overload protected
Protection housing / terminals IP 20 / IP 20
Ambient temperature [°C] -20...60
Display DN0210 LEDPower supply
Output
Fault
1 x green1 x yellow (lights,
if output relay is energised)
1 x red
Display DN0220 LEDPower supply
Output
Fault
1 x green2 x yellow (light, if output relay is energised)
1 x red
Potentiometer SelectionPNP / NPN
Housing material Plastic: PC GF20
Mounting Rail TH35 (according to EN 60715)
Connection
Unit: 4-pole terminal blocks
with 5.0 mm pitch;Connector: 4 poles with
screw connection
Further technical data
Setting range: selectable for PNP and NPN switching sensors
Wiring diagram
Accessories
Type Description Orderno.
Connector, 4 poles with screw terminals, pack of 5(supplied)
E40173
Connector, 4 poles with cage clamps, pack of 5
E40171
Power
21 22 23 24
AC
L L N N
In 129 Sensor
supply
10 pnp/npn
Out765
8
Power
21 22 23 24
AC
L L N N
In2
1613 Sensor
supply
14 pnp/npn
In1
129 Sensor
supply
10 pnp/npn
Out219
1817
20
Out17
65
8
DN0210 (1-channel) DN0220 (2-channel)
38
Safe speed monitor uses standard sensors as pick-ups
ApplicationsThe speed monitor DU110S has been developed forsafety-related minimum-speed monitoring required, forexample, for slip or V-belt monitoring.An application example is the industrial thermo-processing equipment according to EN 746-2. In thiscase, safety-related monitoring of the air exchange isrequired. To do so, monitoring is done via the rotationalspeed monitoring of the fans.
Special featuresThe speed monitor is certified to EN 62061 / SIL 3 andEN ISO 13849-1 cat. 4 / PL e – even though non-safety-related sensors are used as pulse pick-ups.When the safety output has been triggered, it can bereset again manually or automatically.
Easy parameter setting via rotary switch
No restrictions for the design of the cam disc
Monitoring functions can be enabled /disabled
Reliable operation at extreme ambienttemperatures down to -40 °C
Housing width only 25 mm
Safe monitoring of underspeed
Sensors for motion control
39
(04.2015)
Easy setting of the limit speedThe speed is determined via the interval measurementon the inputs where for example two inductive sensorsare used as pulse pick-ups.The user can set the limit speed easily and effectivelyvia three rotary switches (x 1, x 10, multiplier) – eitherin rpm or Hz. It was decided not to use any complicated setting menus.An easy and intuitive setting algorithm prevents unintentional change or manipulation of the set values.
More functionsAutomatic or manual reset of underspeed is possible.This function is set via wire links.The monitoring function can be enabled and disabledvia a switching input.Besides the 2-pole safety relay, transistor outputs canalso be used as output for the status and error indication.
For further technical details please visit: www.ifm.com
Dimensions
22,5
99 108
1
LED
2
114,5
3
35,5
Systems for pulse evaluationSensors for motion control
1) Screw terminals2) Rotary switch3) DIN rail mounting
Wiring diagram
L- L+ S33 S34 S35 S44 S43 S45 13 23
(GND) (GND)
Y3 Y4 Y2 Y1 Y5 Y6 Y7 Y8 14 24
VCC = 24 V DC
24 V DC
Sensor 2 Sensor 1
K1 K2 K1
K2
Enable 1
Enable 2 Fault Overspeed
24 V Restart
Accessories
Type Description Order no.
Plastic housing, 24 V DC, 2.5 A DN1031
Metal housing, 24 V DC, 3.3 A DN4011
Power supplies
Safety speed monitor DU110S
Evaluation system for safe speed monitoring
Operating voltage [V DC]19.2...28.8;
incl. 5 % residual ripple
Nominal voltage [V DC] 24
Current consumption [mA] ≤ 125
Sensor supply 24 V DC / ≤ 70 mA
Protection IP 20 / II
Input characteristicsPulse inputs S34, S43:
“1”: 6 mA / 24 V DC
Adjustable speed range [rpm] 10...49500
Adjustable frequency range [Hz] 0.1...990
Input frequency [Hz] ≤ 5000
Output function
2 safety-related switchingoutputs (floating contacts)
1 fault output “Fault” (positive switching)1 diagnostic output
“Overspeed” (positive switching)
Output characteristics
Fault output “Fault” Y7and diagnostic output
“Overspeed” Y8≤ 20 mA, 24 V DC,
voltage drop ≤ 2 V DC,short-circuit proof,
non safe
Contact rating
6 A, 250 V AC / 24 V DC
(≥ 6 mA); resistive load
Ambient temperature [°C] -40...55
Storage temperature [°C] -40...75
Max. permissible relative [%]humidity
95, non condensing
Housing materials PA (polyamide)
Mounting Rail TH35 (according to EN 60715)
ConnectionScrew terminals; 0.5...2.5 mm² (AWG 12...30)
Technical data
40
True 3D vision sensor with intelligent functions
Mobile 3D smart sensor O3M151The 3D detection of scenes and objects, already a standard on the factory floor, is ready for mobile machines. Apart from new possibilities for vehicle automation (AGV, automatic guided vehicles) this results in new assistance functions for automation tasks.Different integrated functions configurable via the Windows software are available as standard.The simple connection of the 3D smart sensor is carriedout via the CAN bus for mobile applications using theCANopen or SAE J 1939 protocol and/or via the fastEthernet interface using UDP.
Simple application solutions thanks to preprocessed 3D data
Easy integration via predefined CODESYSfunction blocks
Patented pmd time-of-flight technologyfor quick distance detection
Optimised for reliable outdoor use with IP 67 and IP 69K
Enormous range up to 35 m
3D Smart Sensor – Your assistanton mobile machines
Industrial imaging
41
(11.2014)
Camera systems for mobile machines
Description Orderno.
IR system illumination unit (850 nm) for mobile 3D sensors O3M950
Further technical dataSmart sensor O3M151
Accessories
Housing material diecast aluminium
Device connection M12 connector
Protection rating, protection class
IP 67 / IP 69K, III
Operating voltage [V DC] 9...32
Functions and advantages
Powerful 3D time-of-flight measurement (ToF)The principle of this 3D sensor is based on ifm’s patented and award-winning pmd technology. It was specificallydesigned for outdoor use and difficult ambient light situations. Even interference such as sunlight or materials with different reflective characteristics do not influencethe repeatability of the measured data.Powerful electronicsThe integrated 2 x 32-bit processor architecture ensuresa rapid and reliable calculation of the 3D data andfunctions directly integrated in the system with up to50 fps. The complete electronics of the mobile 3D smart sensor is optimised and adapted to the demands andrequirements of mobile machines. Besides shock and vibration resistance self-diagnosticfunctions from the sensor to the IR system illuminationunit are of course also available.Smart functionsThe mobile 3D smart sensor integrates some functionswhich enable to solve a multitude of applications. A highly developed algorithm from the automotive industry is used ensuring, for example, reliable automatic object recognition of up to 20 objects. This functioncan, for example, be used as collision warning. For simple distance tasks typical functions such as minimum / maximum / average distance are available.System parameter setting and monitoringThe parameter setting of the system and live monitoring of the 3D data are carried out via the easy-to-use ifmvision wizard for Windows. As an alternative, parameter setting can also be carried out via function blocks usingthe software CODESYS.Communication interfacesThe preprocessed function data is output via the CANbus using CANopen or SAE J 1939. If needed, the complete 3D information can be processed at the sametime via Ethernet UDP and an external process unit.
Current consumption sensor [mA] < 400
Current consumption [A]system illumination unit < 5
Ambient temperature [°C] -40...85
Interfaces 1x CAN, 1 x fast Ethernet
Supported CAN protocols CANopen, SAE J 1939
Standards and tests (extract)
CE,E1 (UN-ECE R10)
For further technical details please visit: www.ifm.com
Industrial imaging
CAN/RS232 USB interface CANfox EC2112
Adapter cable set for CANfox EC2114
Operating software for vision sensors E3D300
U-shaped holder, suitable for sensor or illumination unit E3M100
Mounting set for clamp mounting, Ø 14mm, stainless steel E3M103
Connection technology
MCI cable, connection sensor / system illumination unit, 1 m E3M121
MCI cable, connection sensor / system illumination unit, 2 m E3M122
Type Description Orderno.
M12 socket, voltage supply system illumination unit, 2 m, PUR cable, 4 poles
E3M131
M12 socket, voltage supply system illumination unit, 10 m, PUR cable, 4 poles
E3M133
Ethernet, cross-over patch cable,2 m, PVC cable, M12 / RJ45 E11898
Ethernet, cross-over patch cable,10 m, PVC cable, M12 / RJ45 E12204
Type of sensor Resolution pixels [pixel]
IlluminationAngle of aperturehorizontal x vertical
[°]
Orderno.
PMD 3D sensor · Type O3M · M12 connector
PMD 3D chip 64 x 16 ext. illumination required70 x 23 O3M151
Max. sampling rate
[Hz]
25/33/50
42
True 3D vision sensor
Mobile 3D sensor O3M150The 3D detection of scenes and objects, already a standard on the factory floor, is ready for mobile machines. Apart from new possibilities for vehicle automation (AGV, automatic guided vehicles) this results in new assistance functions for automation tasks.Besides position data at pixel level the respective distance to the sensor system or an adjustable reference point (world coordinate system) is provided. Thanks tothe permanent output of the entire 3D information viaEthernet UDP optimum conditions for customer-specificapplication solutions are provided to system integrators.
Support for system integrators with data output via Ethernet UDP
Patented pmd time-of-flight technologyfor quick distance detection
Optimised for reliable outdoor use
Robust design with IP 67 and IP 69K
Enormous range up to 35 m
3D sensors for mobile machines
Industrial imaging
43
(11.2014)
Camera systems for mobile machines
Further technical dataO3M150
Housing material diecast aluminium
Device connection M12 connector
Protection rating, protection class
IP 67 / IP 69K, III
Operating voltage [V DC] 9...32
Functions and advantages
Powerful 3D time-of-flight measurement (ToF)The principle of this 3D sensor is based on ifm’s patented and award-winning pmd technology. It was specificallydesigned for outdoor use and difficult ambient light situations. Interference such as sunlight or materialswith different reflective characteristics which occurs inthe area of mobile machines does not influence the repeatability of the measured data.
Powerful electronicsThe integrated 2 x 32-bit processor architecture ensuresa rapid and reliable calculation of the distance image tobe output with up to 50 fps. The complete electronicsof the mobile 3D sensor is optimised and adapted to the demands and requirements of mobile machines. Besides shock and vibration resistance self-diagnosticfunctions from the sensor to the IR system illuminationunit are of course also available.
High system uptimeThe system has various features to ensure uninterrupted operation. They include, among others, a temperature-controlled front lens heating, soiling indication as wellas different status information which can be fetchedfrom CAN.
System parameter setting and monitoringThe parameter setting of the system and live monitoring of the 3D data are carried out via the easy-to-use ifmvision wizard for Windows. As an alternative, parameter setting can also be carried out via function blocks usingthe software CODESYS.
Communication interfacesThe mobile 3D sensor features a fast Ethernet interface(100 Mbit) as well as a CAN interface. The data outputof the complete 3D information is carried out via Ethernet UDP and can be processed using a processunit at the customer’s end. For this version the CAN in-terface is only intended for parameter setting and status output.
Current consumption sensor [mA] < 400
Current consumption [A]system illumination unit < 5
Ambient temperature [°C] -40...85
Interfaces 1x CAN, 1 x fast Ethernet
Supported CAN protocols CANopen, SAE J 1939
Standards and tests (extract)
CE,E1 (UN-ECE R10)
For further technical details please visit: www.ifm.com
Industrial imaging
Description Orderno.
IR system illumination unit (850 nm) for mobile 3D sensors O3M950
Accessories
CAN/RS232 USB interface CANfox EC2112
Adapter cable set for CANfox EC2114
Operating software for vision sensors E3D300
U-shaped bracket, suitable for sensor or illumination unit E3M100
Mounting set for clamp mounting, Ø 14mm, stainless steel E3M103
Connection technology
MCI cable, connection sensor / system illumination unit, 1 m E3M121
MCI cable, connection sensor / system illumination unit, 2 m E3M122
Type Description Orderno.
M12 socket, voltage supply system illumination unit, 2 m, PUR cable, 4 poles
E3M131
M12 socket, voltage supply system illumination unit, 10 m, PUR cable, 4 poles
E3M133
Ethernet, cross-over patch cable,2 m, PVC cable, M12 / RJ45 E11898
Ethernet, cross-over patch cable,10 m, PVC cable, M12 / RJ45 E12204
Type of sensor Resolution pixels [pixel]
Illumination Angle of aperturehorizontal x vertical
[°]
Orderno.
PMD 3D sensor · Type O3M · M12 connector
PMD 3D chip 64 x 16 ext. illumination required70 x 23 O3M150
Max. sampling rate
[Hz]
25/33/50
44
Innovative operating conceptsfor intuitive handling
Incomplete shipments – never againIf a pallet with only one incomplete handling unit reaches the customer, he often returns all goods. This does not only lead to dissatisfaction but also to additional costs. Completeness monitoring provides theremedy. Often individual sensors are installed aboveeach individual handling unit position. This is, however,not very flexible if the handling unit type or size changes. Then changes become necessary. If colour or texture ofthe handling units change, conventional sensors reachtheir limits.All these problems are unknown to completeness monitoring on the basis of 3D sensors: The 3D sensorlooks at the handling unit from above and compares it with the models taught in by the user. It signals anydeviation via a switching output.Continuous exchange with users and extensive hand-ling tests have lead to extraordinarily simple operationand integrability of the sensor.
Different handling units can be taught
Reliable detection of underfill or overfill
Automatic position tracking
Colour-independent and extraneous-lightresistant due to time-of-flight technology(PMD).
Switching outputs and Ethernet processdata interface
Completeness monitoring for thepackaging technology
Industrial imaging
45
(11.2015)
3D sensors
Mounting set for O3D E3D301
Further technical data
Accessories
Operating voltage [V DC] 20.4...28.8
Current consumption [mA]
< 2400 peak current pulsed;
typ. mean value 420
Current rating [mA](per switching output) 100
Real chip resolution 25,000 / 100,000
Resulting resolution 176 x 132 pixels
Function display LED 2 x yellow,2 x green
Illumination 850 nm,infrared
Ambient light [lux] Max. 10,000 (indoor)
Trigger
External; 24 V PNP/NPN according to
IEC 61131-2 type 3
Switching inputs
2 (configurable), 24 V PNP/NPNaccording to
IEC 61131-2 type 3
Switching outputs
3 (configurable), 24 V PNP/NPN, according to IEC 61131-2
Ambient temperature [°C] -10...50
For further technical details please visit: www.ifm.com
Industrial imaging
Connection technology
Type Description Orderno.
Ethernet, cross-over patch cable,2 m, PVC cable, M12 / RJ45 E11898
Ethernet jumper,2 m, PVC cable, M12 / M12 E21138
Type of sensor Materialfront pane /LED window
Angle of aperture
[°]
Protection rating,protection class
Orderno.
PMD 3D sensors · Type O3D · M12 connector
PMD 3D ToF chip Gorilla glass /polyamide
Materialhousing
Aluminium 40 x 30IP 65 / IP 67,III O3D300
Max.field of view size
[m]
2.61 x 3.47
PMD 3D ToF chip Gorilla glass /polyamideAluminium 60 x 45IP 65 / IP 67,
III O3D3023.75 x 5.00
PMD 3D ToF chip Polycarbonate /polyamideStainless steel 40 x 30IP 66 / IP 67,
III O3D3102.61 x 3.47
PMD 3D ToF chip Polycarbonate /polyamideStainless steel 60 x 45IP 66 / IP 67,
III O3D3123.75 x 5.00
Socket, M12,2 m black, PUR cable, 8 poles E11950
Type Description Orderno.
Short-circuit protection, pulsed •
Overload protection •
Parameter setting interface Ethernet 10 Base-T /100 Base-TX
Possible parameter settings Via PC / notebook
Dimensions (H, W, D) [mm] 72 x 65 x 85
Technical data Completeness monitoring
Operating distance [m] 0.3...5
Max. handling unit size 64 objects
Sampling rate / [Hz]switching frequencyThe image repetition frequency is reduced by using the position trackingfunction
10
Minimum size of objects [mm]Object speed: 0...0.2 m/sObject speed: > 0.2 m/s
2545
46
Flexible and universal use forstationary or moving objects
The revolution in intralogisticsWhether pallets, post room, storage building, logisticsor distribution centre: The storage volume that can beused defines the capacity and the costs. A good reason to ensure the best-possible use of thespace requirement during feeding.The new 3D sensor detects the dimensions of thegoods via innovative time-of-flight technology. It signals via threshold values if e.g. package parameters are out-side the defined areas.For automated storage space planning via WMS (Warehouse Management System) or ERP system (Enterprise Resource Planning) it provides the size, ori-entation and position of the objects. The data is alsoused for controlling robots, sorting equipment and distribution gates. Besides robustness the sensor is also distinguished by user-friendly handling and simpleintegration.
Non-contact dimensioning of rectangular objects such as cardboard packages or parcels
Determination and comparison of dimensions, orientation and position
Provides height, width and length to calculate strap length and volume
Quality parameters help with the detection of damaged or deformed objects
Switching outputs and Ethernet processdata interface
Volume determination for storage and conveyor technology
Industrial imaging
47
(11.2015)
3D sensors
Mounting set for O3D E3D301
Further technical data
Accessories
For further technical details please visit: www.ifm.com
Industrial imaging
Connection technology
Type Description Orderno.
Ethernet, cross-over patch cable,2 m, PVC cable, M12 / RJ45 E11898
Ethernet jumper,2 m, PVC cable, M12 / M12 E21138
Type of sensor Materialfront pane /LED window
Angle of aperture
[°]
Protection rating,protection class
Orderno.
PMD 3D sensors · Type O3D · M12 connector
PMD 3D ToF chip Gorilla glass /polyamide
Materialhousing
Aluminium 40 x 30IP 65 / IP 67,III O3D300
Max.field of view size
[m]
2.61 x 3.47
PMD 3D ToF chip Gorilla glass /polyamideAluminium 60 x 45IP 65 / IP 67,
III O3D3023.75 x 5.00
PMD 3D ToF chip Polycarbonate /polyamideStainless steel 40 x 30IP 66 / IP 67,
III O3D3102.61 x 3.47
PMD 3D ToF chip Polycarbonate /polyamideStainless steel 60 x 45IP 66 / IP 67,
III O3D3123.75 x 5.00
Socket, M12,2 m black, PUR cable, 8 poles E11950
Type Description Orderno.
Technical data Dimensioning of the object
Operating distance [m] 0.3...5
Object type Rectangular
Min. object size [mm] 100 x 100 x 100
Typical accuracy [°]for angle of rotation ± 1
Sampling rate / switching frequency [Hz] 1
Typical accuracy [mm]for object position ± 5
Object speed [m/s] < 0.2
Typical accuracy [mm]for object size ± 10
Operating voltage [V DC] 20.4...28.8
Current consumption [mA]
< 2400 peak current pulsed;
typ. mean value 420
Current rating [mA](per switching output) 100
Real chip resolution 25,000 / 100,000
Resulting resolution 176 x 132 pixels
Function display LED 2 x yellow,2 x green
Illumination 850 nm,infrared
Ambient light [lux] Max. 10,000 (indoor)
Trigger
External; 24 V PNP/NPN according to
IEC 61131-2 type 3
Switching inputs
2 (configurable), 24 V PNP/NPNaccording to
IEC 61131-2 type 3
Switching outputs
3 (configurable), 24 V PNP/NPN, according to IEC 61131-2
Ambient temperature [°C] -10...50
Short-circuit protection, pulsed •
Overload protection •
Parameter setting interface Ethernet 10 Base-T /100 Base-TX
Possible parameter settings Via PC / notebook
Dimensions (H, W, D) [mm] 72 x 65 x 85
48
Three-dimensional real-timedetection of any scene
Perspective and colour-coded images of the 3D distance image.
Three-dimensional detection and evaluationThe 3D camera, on the basis of PMD technology, detects scenes and objects at a glance in three dimensions. In contrast to laser scanners it does not require movingcomponents and is thus robust and wear-free. The function principle, the time of flight technology(ToF), can be compared to a laser scanner. However, instead of one there are 23,000 receiving elements arranged on the chip as a matrix. That means that notonly one point but a complete scene is measured inonly one capture. Besides the distance image the camera also provides a grey-scale image of the scene.Intuitive parameter setting software allows easy settingof the camera-specific parameters. Furthermore a soft-ware development kit with example program code indifferent languages is available.
New digital image chip with 23,000 pixels
Provides distance image and grey-scale image
Evaluation with common image processing libraries
Industrially compatible housing
Connection to MATLAB, HALCON, PCL(Point Cloud Library) and ROS (Robot Operating System)
High-resolution 3D camera for innovative vision integration
Industrial imaging
49
(11.2015)
3D cameras
Mounting set for O3D E3D301
Further technical dataAccessories
Operating voltage [V DC] 24
Current consumption [mA] < 1000 (max. 2500)
Current rating [mA](per switching output) 100
Range [m] Typically 5
Unambiguous range [m] 0...30
Sampling rate / [Hz]switching frequency
Max. 20, adjustable
Resolution 176 x 132 pixels
Function display LED 2 x yellow,2 x green
Illumination 850 nm,infrared
Ambient light [lux] Max. 10,000 (indoor)
Trigger
Internal or external: 24 V PNP / NPN selectable,
according to IEC 61131-2 type 2
Switching inputs
Max: 2 (configurable), 24 V PNP / NPN selectable,
according to IEC 61131-2 type 2
Switching outputs
Max: 2 (configurable), 24 V PNP / NPN selectableor 1 analogue output (con-figurable) scalable, 4...20
mA according to IEC 61131-2,
max. load 300 Ω, 0...10 V according to
IEC 61131-2, min. load 10 kΩ
Ambient temperature [°C] -10...50
For further technical details please visit: www.ifm.com
Industrial imaging
Connection technology
Type Description Orderno.
Ethernet, cross-over patch cable,2 m, PVC cable, M12 / RJ45 E11898
Ethernet jumper,2 m, PVC cable, M12 / M12 E21138
PMD 3D camera · Type O3D · M12 connector
Socket, M12,2 m black, PUR cable, 5 poles EVC070
socket, M12,5 m black, PUR cable, 5 poles EVC071
Type Description Orderno.
Short-circuit protection •
Overload protection •
Parameter setting interface Ethernet 10 Base-T /100 Base-TX
Possible parameter settings Via PC / notebook
Type of sensor Materialfront pane /LED window
Angle of aperture
[°]
Protection rating,protection class
Orderno.
Infineon® 3D Image Sensor
Gorilla glass /polyamide
Materialhousing
Aluminium 40 x 30IP65 / IP67,III O3D301
Max.field of view size
[mm]
2.61 x 3.47
Infineon® 3D Image Sensor
Gorilla glass /polyamideAluminium 60 x 45IP65 / IP67,
III O3D3033.75 x 5.00
Infineon® 3D Image Sensor
Polycarbonate /polyamideStainless steel 40 x 30IP66 / IP67,
III O3D3112.61 x 3.47
Infineon® 3D Image Sensor
Polycarbonate /polyamideStainless steel 60 x 45IP66 / IP67,
III O3D3133.75 x 5.00
50
Pressure transmitters withDEUTSCH or AMP connectorfor mobile applications
Miniaturisation for mobile applicationsThe DEUTSCH or AMP connectors of the new PT/PU pressure sensors allow fast and easy installation in mobile machines.The sensors also feature a thin-film measuring cell directly welded with the process connection. This technology guarantees high accuracy in a verycompact housing with only 19 mm across flats at acost-optimised price /performance ratio.
ApplicationsThe PT/PU type sensors are suited for mobile applica-tions and especially for hydraulic and pneumatic appli-cations with high operating pressure.The high vibration and shock resistance, the high protection rating, the excellent EMC resistance and theE1 conformity make the PT/PU sensors particularly suitable for use in mobile machines.
Compact design (AF19) with process connection G 1/4 male
Fast reaction: 2 milliseconds response time
Measuring accuracy < ± 0.8 %, repeatability < ± 0.05 %
Easy connection via DEUTSCH or AMP connector
Robust low-cost solution with welded stainless steel housing
Small and cost-optimised for mobile machines
Process sensors
51
(11.2015)
Pressure sensors
Accessories
Type Description Orderno.
Operating voltage PT [V DC]PU [V DC]
8...3216...32
Common technical data
Medium temperature [°C] -40...125
Materials wetted parts 1.4542 (17-4 PH / 630)*
Protection IP 67 / IP 69K
Step response time [ms] 2
Restrictor •
EMC
Compliant with UN-ECE10Rev. 4
ISO 11452: 100 V/mEN61326
Reverse polarity protection •
Adapters; G 1/4 - G 1/2, high-grade stainless steel (316Ti/1.4571) E30135
For further technical details please visit: www.ifm.com
Process sensors
Measuring rangerelative pressure
[bar]
Poverloadmax.[bar]
Pburstmin.[bar]
Orderno.
Output function 0...10 V, DEUTSCH connector
0...10 25 300 PU5704
0...25 65 600 PU5703
0...100 250 1000 PU5702
0...250 625 1200 PU5701
0...400 1000 1700 PU5700
0...600 1500 2400 PU5760
Output function 0...10 V, AMP connector
0...10 300 PU5604
0...25 600 PU5603
0...100 1000 PU5602
0...250 1200 PU5601
0...400 1700 PU5600
0...600 2400 PU5660
Accuracy / deviation(in % of the span)Linearity errorLinearityHysteresisRepeatabilityLong-term stabilityTemperature coefficients (TEMPCO)in the temperature range 0 ... 80 °C(in % of the span per 10 K)TEMPCO of zeroTEMPCO of the spanTemperature coefficients (TEMPCO)in the temperature ranges -40...0 °C and 80...125 °C(in % of the span per 10 K)TEMPCO of zeroTEMPCO of the span
< ± 0.8< ± 0.25 BFSL / < ± 0.5 LS
< ± 0.2< ± 0.05< ± 0.1
< ± 0.1< ± 0.1
< ± 0.2< ± 0.2
25
65
250
625
1000
1500
A
B OUT
+L
Wiring diagram
1
3 L +
OUT
Dimensions
71,5
51,4
12
G 41
19
1
19
21,825,4
51,9
72
25,8
12
G 41
19
1
21,8
19
14,35
Type PT57/PU57
Type PT56/PU56
1) FKM seal / DIN 3869
Type PT56Type PT57
A
C
BOUT
L -
L +L + 1
2
3OUT
L +
L -
Type PU56Type PU57
Measuring rangerelative pressure
[bar]
Poverloadmax.[bar]
Pburstmin.[bar]
Orderno.
Output function 4…20 mA, DEUTSCH connector
0...10 25 300
0...25 65 600
0...100 250 1000
0...250 625 1200
0...400 1000 1700
0...600 1500 2400
Output function 4…20 mA, AMP connector
0...10 300
0...25 600
0...100 1000
0...250 1200
0...400 1700
0...600 2400
25
65
250
625
1000
1500
PT5704
PT5703
PT5702
PT5701
PT5700
PT5760
PT5604
PT5603
PT5602
PT5601
PT5600
PT5660
* Characteristics similar to stainless steel (e.g. 304/1.4301) but higher strength
52
Process sensors
High-grade stainless steel submersible pressure transmit-ter of different cable materials
Level measurement in a water treatment plant
Application areasThe PS series submersible pressure transmitters are used for level measurement in containers, tanks, wells,flowing water, bore holes and wastewater plants. Theaccuracy of 0.5 % and the long-term stability of 0.2 %per year contribute to the reliable operation of thetransmitter.
Robust, reliable and flexibleAll submersible pressure transmitters have a robusthigh-grade stainless steel housing. For standard applica-tions the favourably priced PUR cable can be used. For applications where a high resistance to media is requested (e.g. slurry, oils or fuels) the FEP cable is available. The ATEX submersible pressure transmitters of thePS3xxA series are designed for level measurement inareas subject to explosion. The sensors can be used inzone 0, 1, 2 or zone 20, 21, 22 as well as in mining.The GL approval allows an application in the maritimesector.
PUR or FEP cable for high resistance to media
Version with ATEX approval for group Icat. M1 and group II cat. 1G and 1D.
Good overall accuracy and long-term stability
Pressure compensation via internally vented cable
Hydrostatic level measurement for a wide range of applications
53
(04.2015)
Process sensors
For further technical details please visit: www.ifm.com
Pressure sensors
Splitter box *with vent and terminal block E30401
Additional weight, approx. 500 g E30402
Filter element * E30400
Cable fixing clamps * E30399
Submersible pressure transmitters with PUR cable for standard applications
0.6
0.6
0.6
4
4
4
1000 N
1000 N
1000 N
Measuring rangeRelative pressure
[bar]
ApprovalsCE / EX / GL
Overload pressure
[bar]
Pull force cable
1
1
5
5
1000 N
1000 N
Cable length
[m]
PS3407
PS3427
PS3607
Orderno.
PS3417
PS3617
0.25 2 1000 N
10
15
30
15
30
5
• / – / –
• / – / –
• / – / –
• / – / –
• / – / –
• / – / – PS3208
Operating voltage [V DC] 18...30
Analogue output [mA] 4...20
Accuracy / deviation(in % of the span)Accuracy (BFSL)Accuracy incl. non-linearityNon-linearity (BFSL)Long-term stability per year
≤ 0.25 (PS3: 0.5)≤ 0.5 (PS3: 1)
≤ 0.2≤ 0.2
Design PS3Ambient temperature / [°C]Medium temperature
-10...50
Design PS4Ambient temperature / [°C]Medium temperature
-10...85
Design PS3 ATEX approvalAmbient temperature / [°C]Medium temperature
1G, 1/2G, 2G:T6 -10...60, T5: -10...80,
T4: -10...851D, 1/2D, 2D:
-10...40 (750 mW) / -10...70 (650 mW) / -
10...85 (550 mW)
Housing material High-grade stainless steel (316Ti / 1.4571)
Further technical data
Accessories
Type Description Orderno.
* use only outside the hazardous area
Submersible pressure transmitters with FEP cable for high resistance to media
0.6
1
3
5
500 N
500 N
PS4407
PS4417
0.25 2 500 N
10
15
5
• / – / –
• / – / –
• / – / – PS4208
Submersible pressure transmitters with FEP cable for hazardous areas
0.6
1
4
5
500 N
500 N
PS307A
PS317A
0.25 2 500 N
10
15
5
• / • / •
• / • / •
• / • / • PS308A
Temperature coefficients (TEMPCO)(in % of the span per 10 K)Greatest TEMPCO of zeroGreatest TEMPCO of the span
≤ 0.2≤ 0.2
100
27
Example PS3208
Dimensions
54
Process sensors
Even easier to use and withimproved visualisation
The overall package makes the differenceAfter 20 years of successful ifm pressure sensor history,the new generation of PN sensors was developed inclose coordination with the users. Its modern and user-friendly design stands out. High overload protection, IP 67 and the captive laser labelling make the new PN sensors your perfect partner even in the most harshenvironments.
Everything at a glanceAlthough the housing size has remained unchanged,the display size has been increased once again and theswitching status LEDs on the sensor head can be clearlyseen from all sides. The display can be switched fromthe indication of “red” to an alternating indication of“red - green”. So, switching states can be highlightedor an independent colour window can be created.
FlexibleOnce fitted, rotate the sensor in any direction: The newPN allows free rotation as well as any mounting position using angle brackets as an accessory.
Clearly indicate the acceptable ranges: programmable red / green display
The process connection can be rotated foroptimum alignment
Fast switch point setting by using threepushbuttons
Visualisation of the switching states byclearly visible LEDs
Can still be identified after many years:captive laser labelling on stainless steelhousing
An update for the bestseller: PNpressure sensor with a new look
55
(04.2015)
Process sensors
For further technical details please visit: www.ifm.com
Pressure sensors
Accessories
Type Description Order no.
Memory plug, parameter memory for IO-Link sensors E30398
IO-Link interface, current consumptionfrom USB port E30396
Operating voltage [V DC] 18...30
Current rating [mA] 200(up to 60 °C environment)
Accuracy / deviation(in % of the span) turn down 1:1Deviation of the switch pointLinearity error
Repeatability
Temperature coefficients (TEMPCO)in the temperature range 0 ... 80 °C(in % of the span per 10 K)Greatest TEMPCO of zeroGreatest TEMPCO of the span
< ± 0.5 / (0.4 PN2)< ± 0.25 (BFSL)
< ± 0.5 (LS)< ± 0.1
< ± 0.2< ± 0.2
Communication interfaceIO-Link 1.1
COM2 slave; 38.4 kbaud
Medium temperature [°C] -25...80
Switching frequency [Hz] ≤ 170
Protection IP 67
Shock resistance [g] 50
Vibration resistance [g] 20
Type of pressure: relative pressureLiquids and gases
Common technical data
Connection technology
Type Description Order no.
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Tag clip E30422
Damping screw, G 1/4 female E30419
Damping screw, G 1/4 male E30057
Protective cover, new generation E30420
Angle bracket, PA66 E30421
Siphon, G 1/4,steel (1.0345) E30140
LINERECORDER SENSOR, software for parameter setting and set-up of IO-Link sensors
QA0001
M12 connectoroutput function programmable
NO/NC+ analogue:
4...20 mA/0...10 V
2 x NO/NC or1 x NO/NC + 1 x analogue
(4...20 mA/0...10 V; scalable)
0...400 bar
0...250 bar
0...100 bar
Ceramic-capacitive
Measuring rangerelative pressure
Order no.G 1/4 male
Measuring cell
0...25 bar
-1...10 bar
0...2,5 bar
0...1000 mbar
-12,5...250 mbar
-1000...1000 mbar
Order no.G 1/4
female
PN2570
PN2571
PN2592
Order no.G 1/4 male
PN2593
PN2594
PN2596
PN2070
0...600 barMetal
(thin film)
PN2560PN2160
PN2071
PN2092
PN2093
PN2094
PN2096
PN2597
PN2598
PN2097
PN2098
PN2599PN2099
Order no.G 1/4
female
PN7570
PN7571
PN7592
Order no.G 1/4 male
PN7593
PN7594
PN7596
PN7070
PN7071
PN7092
PN7093
PN7094
PN7096
PN7597
–
PN7097
–
PN7599PN7099
-1000...0 mbar
-500...500 mbar
––
PN2569PN2169
––
––
Order no.G 1/4
female
PN7560PN7160
PN3570
PN3571
PN3592
PN3593
PN3594
PN3596
PN3070
PN3560PN3160
PN3071
PN3092
PN3093
PN3094
PN3096
PN3597
–
PN3097
–
––
PN3529PN3129
––
2 x NO/NC
56
More plant transparency andservice information on site
More plant transparencyThe IO-Link display is a flexible solution to display process values, texts and messages in a plant. It displays up tofour assigned process values, alarms and warnings.Clear text and as an option a colour change of text andbackground can be used for a quick overview. By means of buttons the user can trigger control actions of the PLC or acknowledge messages.
Easy integrationThe IO-Link display is connected to an IO-Link masterand controlled via PLC. No special software is requiredfor configuration. Texts and settings can be predetermined via an IO-Linkdevice tool such as LINERECORDER SENSOR. Texts andsettings can be adapted even during operation via thePLC.
Four measured values / text displays andfour message windows for free text
Colour change for text and background
Flexible adaptation of the display, alsoduring operation
IO-Link 1.1 compatible
Easy integration into each IO-Link structure
IO-Link display: process values at a glance
Process sensors
57
(11.2015)
IO-Link display
For further technical details please visit: www.ifm.com
Process sensors
Resolution pixels
Display type Displayillumination
Orderno.
1.44“ colour display
128 x 128 TFT LED E30391
Wiring
Dimensions
Technical data
IO-Link displayE30391
Operating voltage [V DC] 18...30
Current consumption [mA] < 47
Protection rating / protection class
IP 65, IP 67 / III
Reverse polarity protection •
Ambient temperature [°C] 0...60
EMC EN 61000-6-2 EN 61000-6-4
Shock resistance [g] 20 (11 ms)
Vibration resistance [g] 20 (10...50 Hz)
Housing materials
Stainless steel (303/1.4305); PC; PBT-GF 30;
PPS; PA 6.6; FKM
Connection M12 connector
Communication interfaceIO-Link deviceType of transmissionIO-Link revisionSDCI standard
COM2 (38.4 kbaud)1.1
IEC 61131-9
Connection technology
Type Description Orderno.
M12 jumper1 m black, PUR cable EVC042
M12 jumper2 m black, PUR cable EVC043
M12 jumper, 3 m black, PUR cable EVC102
M12 jumper, 5 m black, PUR cable EVC044
M12 jumper, 10 m black, PUR cable EVC493
BN1
BK4
BU3
L+
L
OUT
45 34
86
101
39,5
11M
12x1
58
Calorimetric flow meter for liquids and gases
Measurement techniqueThe SA volumetric flow sensor operates using the calorimetric measuring principle. Two measuring elements as well as a heat source are located on themeasuring tip. The physical effect that a flowing medium absorbs heat energy and conducts it away isused. The resulting temperature change is an indicationof flow.
Device functionThe new SA-type sensor has been designed to detectand measure flow and temperature even in large internal pipe diameters up to 400 mm. Therefore it serves different applications. Switching outputs, analogue signals and IO-Link provide variousoptions to further process the signals. That means thatthe user is best-equipped for Industry 4.0.
Optimised for water, oils, glycol and air
Fast response time and integrated temperature measurement
Red/green colour change for process values
Internal pipe diameter selectable from15...400 mm
The process connection can be rotated foroptimum alignment
New benchmark in thermal flowmeasurement
Process sensors
59
(11.2015)
Flow sensors / flow meters
For further technical details please visit: www.ifm.com
Common technical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 100
Current rating [mA] 250
Housing materials
High grade stainless steel (1.4404/316L);
PBT-GF 20; PBT-GF 30
Connection M12 connector
Accuracy temperature measurement ± 1 K
TypeSA
Protection rating, protection class IP 65 / IP 67, III
BN
WH
BK
BU
4
1
3
2 OUT2
L+
L
OUT1
Wiring
Measuring rangeliquid / gaseous
[cm/s]
Mediumtemperature
[°C]
Response time[s]
Orderno.
M12 connector · electrical design DC PNP
5...300 / 200...10000 -20...90 0.5 SA5000
Probe length
[mm]
45
5...300 / 200...10000 -20...100 0.5 SA4100100
5...300 / 200...10000 -20...100 0.5 SA4300200
Pressure resistance
[bar]
100
50
50
Process sensors
Accessories
Type Description Orderno.
Adapter M18x1.5 – G 1/2
Progressive ring fitting G 1/2, flat seal E40258
Type
M18
Progressive ring
Progressive ring
Connection technology
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
M12 socket,2 m orange, PVC cable EVT064
M12 socket,5 m orange, PVC cable EVT001
USB IO-Link master for parameter settingand analysis of unitsSupported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
Dimensions
Accuracy flow measurement
± (5 % MW + 2 % VMR) at referenceconditions
E40096
Adapter M18x1.5 – G 1/4 E40099
4048
M12
x134
3
2
1
4
8145
15
8
22
Example SA5000
1) LEDs (display unit / switching status)2) 4-digit alphanumeric display / alternating indication of red and green3) Programming buttons4) Upper part of the housing can be rotated by 345°
60
Vortex inline volumetric flow sensors with user-friendly display
Monitoring the cooling circuits at a welding gun
Turbulence as a measure for the flowBehind a blunt body (or shedder) integrated in themeasuring pipe, the flowing medium generates swirlingvortices depending on the velocity. These vortices aredetected by a piezoceramic sensor. If the cross-section is known, the number of the vortices allows to determinethe flow rate.This flow rate measurement principle, known as vortex(or vortex shedding) principle, is almost independent ofpressure and temperature fluctuations of the medium.It allows a simple design and thus a low-cost production of sensors for flow rate measurement.The current flow and temperature are output as stan-dardised current signal (4...20 mA), as frequency signal,switching output or via IO-Link as option.
Integrated temperature measurement
Electronically rotatable multi-colour display
Rotatable G and R process connections as option
Red/green colour change for process values adjustable
Can be used for water with and withoutconductivity (deionised water)
The alternative: Vortex sensor instead of vane
Process sensors
61
(04.2015)
Flow sensors / flow meters
For further technical details please visit: www.ifm.com
Common technical data
Operating voltage [V] 18...30 DC
Current consumption [mA] typ. 25 (at 24 V)
Accuracy flow measurement ± (2 % MV + 2 % VMR)
Output 1(for DC PNP / NPN version)
IO-Link, switching output
or frequency output flow
Output 2(for DC PNP / NPN version)
Switching output flow / temperature
or frequency output flow /
temperature
Accuracy temperature monitoring ± 1 K
TypeSV4, SV5, SV7
Protection rating, protection class IP 65 / IP 67, III
BN
WH
BK
BU
4
1
3
2 OUT2
L+
L
OUT1
Wiring diagram
Measuring range
[l/min]
Response timeT90[s]
Mediumtemperature
[°C]
Max. operatingpressure
[bar]
Orderno.
M12 connector · electrical design DC PNP / NPN · frequency · IO-Link
1.0...20 -10...90 12 SV4200
Processconnection
G 1/2
1.0...20 -10...90 12 SV4500Rc 1/2
2.0...40 -10...90 12 SV5200G 1/2
2.0...40 -10...90 12 SV5500Rc 1/2
5.0...100 -10...90 12 SV7200G 3/4
5.0...100
Nominal diameter
[Ø]
-10...90 12 SV7500Rc 3/4
Connection technology
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m orange, PVC cable EVT064
Socket, M12,5 m orange, PVC cable EVT001
Process sensors
Accessories
Type Description Orderno.
Mounting plate E40249
Adjustment valve, G 1/2 E40250
Adjustment valve, G 3/4 E40251
< 1
< 1
< 1
< 1
< 1
< 1
DN8
DN8
DN10
DN10
DN20
DN20
M12 connector · electrical design DC 2 x analogue 4...20 mA
1.0...20 < 1-10...90 12 SV4204G 1/2
1.0...20 < 1-10...90 12 SV4504Rc 1/2
2.0...40 < 1-10...90 12 SV5204G 1/2
2.0...40 < 1-10...90 12 SV5504Rc 1/2
5.0...100 < 1-10...90 12 SV7204G 3/4
5.0...100 < 1
DN8
DN8
DN10
DN10
DN20
DN20-10...90 12 SV7504Rc 3/4
IO-Link interface, current consumptionfrom USB port E30396
62
Compact mechatronic inlineflow meter with backflowprevention
Mechatronic flow sensorThe new mechatronic flow sensor of the SBY seriesfunctions using the principle of a spring-mounted piston. The piston, located in the valve seat in the housing, is lifted by the flowing medium against the spring resistance.For binary signal output the piston position is detectedby an inductive sensor. The spring resistance leads toreliable reset of the piston to its initial position with decreasing flow. This ensures position-independent installation of the flow sensor preventing backflow.The switch points can be easily set and fixed via a setting screw. The robust mechanical design ensuresuse in harsh environments. The units are maintenance-free.
Measuring range from 0.2...4 l/min
Compact design
Very fast response time of ≤ 10 ms
No inlet and outlet pipe lengths required
Independent of pressure and temperaturefluctuations
New flow sensor now also forsmallest quantities
Process sensors
63
(11.2015)
Flow sensors / flow meters
For further technical details please visit: www.ifm.com
Current consumption [mA] < 15
Ambient temperature [°C] 0...60
Protection rating, protection class IP 65 / IP 67, III
Housing materials
Brass chemically nickel-plated;
anodised aluminium; PA
Materials in contact with the medium
High-grade stainless steel(301/1.4310);
high-grade stainless steel(316/1.4401);
PBT; brass chemically nickel-plated; PPS;
O-ring: FKM Polyolefin
Short-circuit protection •
Further technical data
Overload protection •
L+
L
BN1
4 BK
3 BU
Wiring
Process connection
Pressure resistance
[bar]
Measuring range
[l/min]
Response time
[ms]
Orderno.
M12 connector · electrical design DC PNP
Rp 1/2 800.2...4 ≤ 10 SBY321
Operating voltage
[V]
24 DC
Type
Connection technology
Type Description Orderno.
M12 socket,2 m black, PUR cable EVC001
M12 socket,5 m black, PUR cable EVC002
M12 socket,2 m black, PUR cable EVC004
M12 socket,5 m black, PUR cable EVC005
M12 socket,2 m orange, PVC cable EVT064
M12 socket,5 m orange, PVC cable EVT001
Process sensors
Connection M12 connector
M12
94...
99
27
Rp
½
Rp
½
66,518
107...113
13 13
Dimensions
64
New mechatronic inline volumetric flow sensors withdisplay
Mechatronic flow sensorThe flow sensor works on the principle of spring-supported piston: The piston, located in the valve seatin the housing, is lifted by the flowing medium againstthe spring. The piston position is monitored via a magnetic fieldsensor and is output as an analogue signal. The springforces the piston to return to its original position withdecreasing flow. This ensures position-independent installation of the flow sensor preventing backflow. The sensor head can be rotated by 360° so that it canbe read in any position.
Optimised for water and oils
Integrated temperature measurement
No inlet and outlet pipe lengths required
Red/green colour change for process values
Very fast response time of < 10 ms
The smart float-type flow meter
Process sensors
65
(04.2015)
Flow sensors / flow meters
For further technical details please visit: www.ifm.com
Common technical data
Operating voltage [V DC] 18...30
Current consumption [mA] < 50
Accuracy flow measurement ± (4 % MV + 1 % VMR)
Output 1
IO-Link, switching output, frequency output
flow / temperature
Output 2
Switching output flow,analogue output 4...20 mA flow or temperature
Accuracy temperature monitoring ± 3 K
TypeSBY, SBG
Protection rating, protection class IP 65 / IP 67, III
BN
WH
BK
BU
4
1
3
2 OUT2
L+
L
OUT1
Wiring diagram
Measuring range
[l/min]
Response time
[ms]
Medium temperature
[°C]
Max. operating pressure
[bar]
Orderno.
M12 connector · electrical design DC PNP / NPN
< 10-10...100 40 SBY232
Process connection
Rp 3/4
< 10-10...100 40 SBY233Rp 3/4
< 10-10...100 40 SBY234Rp 3/4
< 10-10...100 25 SBY246Rp 1
Type
< 10-10...100 25 SBY257Rp 1 1/2
< 10-10...100 40 SBG232G 1/2
< 10-10...100 40 SBG233G 1/2
< 10-10...100 40 SBG234G 1/2
< 10-10...100 25 SBG246G 3/4
< 10-10...100 25 SBG257G 1 1/4
Connection technology
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m orange, PVC cable EVT064
Socket, M12,5 m orange, PVC cable EVT001
Process sensors
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
0.3...15
0.5...25
1.0...50
2.0...100
4.0...200
0.3...15
0.5...25
1.0...50
2.0...100
4.0...200
IO-Link interface, current consumptionfrom USB port E30396
Accessories
Type Description Orderno.
66
Reliable level detection – LMT
Level detection in explosive atmospheresLMT sensors reliably detect levels in storage tanks in explosive areas. They can be used in zones 2 and 22.
Food-gradeThe sensor with its high-quality housing materials suchas high-grade stainless steel (316L / 1.4404) and PEEKmeets all requirements for hygienic areas. This includesapprovals such as EHEDG and FDA.
Versatile sensor for all mediaThe LMT can be adjusted to almost all liquid and viscous media as well as powders. The distinction between two media in the same applica-tion is possible due to the two switching outputs whichcan be set independently. Convenient parameter setting is made via IO-Link.
Approved for ATEX areas of category3D/3G
“Plug & Play“ – factory preset to oil-basedmedia
Can be set to other media such as alcoholusing IO-Link
Hygienic design with maintenance-freesealing concept
Shock and vibration resistant in a robuststainless steel housing
Hygienic point level sensor especially for hazardous areas
Process sensors
67
(11.2015)
Level sensors
Process connection
Installation length [mm]
Approval Protection
[hazardous areas]*
Orderno.
Application: liquids, viscous media and powdersM12 connection · output function 2 x NO/NC programmable · 4-wire DC PNP · IO-Link 1.1
Medium temperatureoils, oil-based media,
powder
G 1/2 12 EHEDG, FDA -20...85 °C IP 67 / III LMT01A
G 1/2 153 EHEDG, FDA -20...85 °C IP 67 / III LMT03A
G 1/2 253 EHEDG, FDA -20...85 °C IP 67 / III LMT04A
Accessories
Type DescriptionHigh-grade stainless steel
Orderno.
Current rating [mA] 100
Housing materials
high-grade stainless steel (1.4404 / 316L), (1.4571 / 316Ti),PEEK; PEI; FKM
Materials in contactwith the medium
high-grade stainless steel (1.4404 / 316L), (1.4571 / 316Ti),
PEEK; FKM
Shock resistance [g] 50
Vibration resistance [g](LMT03A, LMT04A) 8
Vibration resistance [g](LMT01A) 20
Ambient temperature [°C] -20...60
EMC (LMT03A, LMT04A)Closed tanks
EN 61000-6-2EN 61000-6-4
EMC (LMT01A)Open tanksClosed tanks
EN 61000-6-2EN 61000-6-4EN 61000-6-3
Operating voltage [V] 18...30 DC
Current consumption [mA] < 50
Further technical data
Clamp adapter G 1/2 female – Clamp 1“–1.5“ E33401
Clamp adapter G 1/2 female – Clamp 2“ E33402
Welding adapter ball, G 1/2 E30055
Welding adapter collar, G 1/2 E30056
Welding adapter,cylindrical, for tanks, G 1/2 E43300
Welding adapter,cylindrical, for pipes, G 1/2 E43301
Screw-in adapter G1/2 female – G 3/4 male E43302
Screw-in adapter G1/2 female – G 1 male E43303
Screw-in adapter G1/2 female – 3/4 NPT E43313
Clamp adapter, G 1/2 female – Varivent D50 E43306
Clamp adapter, G 1/2 female – Varivent D68 E43307
Accessories
Type Description Orderno.
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumptionfrom USB port: max. 500 mA
E30396
Memory plug, parameter memoryfor IO-Link sensors E30398
T-piece, DN 25 E43316
T-piece, DN 40 E43317
T-piece, DN 50 E43318
For further technical details please visit: www.ifm.com
Welding adapter, long design for deeper installation, G 1/2 E43319
Process sensors
ATEX approval group II, category 3D / 3G
Communication interface IO-Link 1.1
Connection M12 connector
LINERECORDER SENSOR,Software for parameter setting and setting up IO-Link sensors
QA0001
USB IO-Link master for parameter settingand analysis of unitsSupported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
*IP 68, IP 69K outside the hazardous area
Connection technology
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC04A
Socket, M12,5 m black, PUR cable EVC05A
Socket, M12,10 m black, PUR cable EVC06A
68
LR level sensor in a new design with extended functions
ApplicationHarsh environment conditions or high temperaturesleave the LR2050 cold. Installation in confined spacesor detection of oils using a coaxial pipe is no problemfor LR, either. LR flexibly adapts to any applicationthanks to the installation adjustment and the modularconcept.
Successful thanks to modular conceptThe probes can be shortened, or changed, so the LR reduces stock-keeping and simplifies replacement.
User-friendly settingEven before installation the user can set the sensor parameters via pushbuttons or IO-Link on the PC. Installation adjustment is made on site via pushbutton,if required.
Mounting adjustment enables position-independent installation
Medium temperature up to 100 °C
Simulation function facilitates testing ofthe plant software
Automatic detection of the rod length
Probe lengths of 15...200 cm
Continuous level measurement inharsh environments
Process sensors
69
(11.2015)
Level sensors
Protection rating/protection class
Max.tank pressure
[bar]
-1...4 IP 68, IP 69K / III
Accessories (to be ordered separately)
Type Description Orderno.
For further technical details please visit: www.ifm.com
Process sensors
Process connection Medium temperature
[°C]
Orderno.
M12 connector · IO-Link 1.1
G 3/4 -20...100 LR2050
Current consumption [mA]
Dielectric constant medium
Ambient temperature [°C]
Metals in contactwith the medium
Housing materials
Power-on delay time [s]
Operating voltage [V] 18...30 DC
Current rating [mA] 200
Further technical data
IO-Link device type of transmission
Rods stainless steel (303 / 1.4305)
Coaxial pipes stainless steel (303 / 1.4305)
Flange plates stainless steel (303 / 1.4305)
Application: aqueous media, coolants, cleaning agents, oils. *
Flange plate, LR 73-90 E43201
Flange plate, LR 73 - 90 / NPT E43206
Flange plate, LR 65-80 E43202
E43203240 mm
E43204450 mm
E43226300 mm
E43205700 mm
E43227500 mm
E432071000 mm
E432081200 mm
E432091400 mm
E432101600 mm * A coaxial pipe is required for the unit to function correctly in lowdielectric media.
E43211240 mm
E43212450 mm
E43213700 mm
E432141000 mm
E432151200 mm
E432161400 mm
E432171600 mm
E43228300 mm
E43229500 mm
G 3/4
Connection technology
Type Description Orderno.
Socket, M12, 4-pole2 m black, PUR cable EVC004
Socket, M12, 4-pole5 m black, PUR cable EVC005
Socket, M12, 4-pole2 m black, PUR cable, LED EVC007
Socket, M12, 4-pole5 m black, PUR cable, LED EVC008
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumptionfrom USB port: max. 500 mA
E30396
Memory plug, parameter memoryfor IO-Link sensors E30398
LINERECORDER SENSOR,software for parameter setting and setting up IO-Link sensors
QA0001
IO-Link accessories
Type Description Orderno.
< 50
1.8...5*> 5
-40...80
high-grade stainless steel(316L / 1.4404,
316S12 / 14435), PTFE, FKM
high-grade stainless steel(316L / 1.4404),
PEI, PBT, PTFE, FKM
≤ 3
1.1
E43351210 mm
E43352265 mm
E433532000 mm
Coaxial pipes, slotted stainless steel (304S15 / 1.4301)
700 mm E43333
1200 mm E43334
E43354210 mm
E43355265 mm
E433562000 mm
E43218450 mm
E43219700 mm
E432201000 mm
E432211600 mm
3/4" NPT
70
Reliable and fast alternativeto tuning forks
In spite of harsh conditions such as foam or depositsLMT194 reliably prevents overflow of the tank.
Reliable and flexibleThe LMTx9x sensor family provides dependable overflow protection. Different lengths and process connectionsallow versatile and position-independent installation.
IO-Link creates transparencyThe sensors can be adjusted to all liquids that are hazardous to water. Parameters are conveniently set on the PC or via IO-Link and USB interface. The digitaltransmission of measured values creates maximumtransparency.
RobustThe high-quality high-grade stainless steel housing isshock and vibration resistant.
Flexible installation independent of theorientation
Shock and vibration resistant in a robuststainless steel housing
Plug & Play – Factory default setting to hydrous media
Can be set to other media such as oil using IO-Link
Suppression of deposits
Maintenance-free overflow protection to WHG*
Process sensors
* German Federal Water Act
71
(04.2015)
Level sensors
Process connection Installation length
[mm]
Medium temperatureoils, fats, bulk materials
[°C]*
Orderno.
Medium: Aqueous media · Can be set to other media using IO-Link 1.1M12 connector · 4-wire DC PNP
Medium temperaturewater-based media
[°C]
G 1/2 12 0...85 0...100 LMT191
G 1/2 153 0...85 0...100 LMT194
G 1 38 0...85 0...100 LMT392
G 3/4 28 0...85 0...100 LMT292
G 1/2 38 0...85 0...100 LMT192
G 1/2 253 0...85 0...100 LMT195
Accessories
Type DescriptionHigh-grade stainless steel
Orderno.
Max. medium temperature [°C](WHG) 100
Housing materials
PEEK;high-grade stainless steel
(316L/1.4404),PA12, FPM
Protection IP 68 / IP 69K, III
Materials in contactwith the medium
PEEK; high-grade stainless steel
(316L/1.4404), FPM
Shock resistance [g] 50
Vibration resistance [g] 20
Max. ambient temperature [°C](WHG) 0...85
EMCClosed tanks:Open tanks:
EN 6100-6-2:2005EN 6100-6-3:2006EN 6100-6-4:2006
Operating voltage [V] 18...30 DC
Current rating [mA] 100
Further technical data
Clamp adapter, G 1/2 female – Clamp 1"–1.5" E33401
Clamp adapter, G 1/2 female – Clamp 2" E33402
Welding adapter ball, G 1/2 E30055
Welding adapter collar, G 1/2 E30056
Welding adapter,cylindrical, for tanks, G 1/2 E43300
Welding adapter,cylindrical, for pipes, G 1/2 E43301
Screw-in adapter, G 1/2 female – G 3/4 male E43302
Screw-in adapter, G 1/2 female – G 1 male E43303
Screw-in adapter, G 1/2 female – 3/4 NPT E43313
Accessories
Type Description Orderno.
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumptionfrom USB port: max. 500 mA
E30396
For further technical details please visit: www.ifm.com
Welding mandrel, G 1/2 E43314
Sealing plug, G 1/2 E43308
Welding adapter, long design for deeper installation, G 1/2 E43319
Process sensors
LINERECORDER SENSOR,software for parameter setting and setting up IO-Link sensors
QA0001
* For operation to WHG
72
Reliable and precise medium detection in hygienicapplications
Versatile useWhether smaller storage tanks, compensating tanks,separators or in filling processes: There are no limits toapplications for LR. Even adverse operating conditionssuch as foam or high temperature do not affect preciselevel detection.
Successful thanks to modular conceptThe probes can be shortened, or changed, so the LR reduces stock-keeping and simplifies replacement. IO-Link means the fiddly parameter setting on the device is a matter of the past.
Resistant materialsHigh-quality materials such as PEEK and EPDM as sealing material or the high-grade stainless steel housing aresuitable for internal and external cleaning and resist themost adverse operating conditions.
Installation adjustment for optimum setting to the installation situation
Aseptoflex Vario thread for a multitude of process adapters
Probe lengths of 15...200 cm
Suitable for medium temperatures upto150 °C
Level sensor with modular probe concept
Process sensors
73
(04.2015)
Level sensors
Protection rating/protection class
Max.tank pressure
[bar]
-1...40 IP 69K, III
Accessories
Type Description Orderno.
0.15 m, high-grade stainless steel (316L/1.4404) E43345
0.3 m, high-grade stainless steel (316L/1.4404) E43346
0.5 m, high-grade stainless steel (316L/1.4404) E43340
0.7 m, high-grade stainless steel (316L/1.4404) E43347
1.0 m, high-grade stainless steel (316L/1.4404) E43341
1.5 m, high-grade stainless steel (316L/1.4404) E43348
2.0 m, high-grade stainless steel (316L/1.4404) E43342
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumptionfrom USB port: max. 500 mA
E30396
Memory plug, parameter memoryfor IO-Link sensors E30398
For further technical details please visit: www.ifm.com
Process sensors
LINERECORDER SENSOR,software for parameter setting and setting up IO-Link sensors
QA0001
Process connection Medium temperature
[°C]
Orderno.
M12 connector · IO-Link 1.1
Aseptoflex Vario -40...150 LR2750
Current consumption [mA] < 80
Dielectric constant medium > 5
Ambient temperature [°C] -40...80
Metals in contactwith the medium
high-grade stainless steel(316L/1.4404), PEEK, EPDM
Housing materialshigh-grade stainless steel
(316L/1.4404), PEI, PFA, PBT, FKM
Power-on delay time [s] ≤ 3
Operating voltage [V] 18...30 DC
Current rating [mA] 200
Further technical data
IO-Link device type of transmission 1.1
Probes for hygienic LR processes
Pipe fitting,DN40 (1.5") E33212
Clamp adapter,Clamp 2" E33202
Pipe fitting,DN50 (2") E33213
Clamp adapter,Clamp 1-1.5" E33201
Aseptoflex Vario adapter
IO-Link
Connection technology
Type Description Orderno.
Socket, M12, 4-pole,5 m orange, PVC cable EVT001
Socket, M12, 4-pole,2 m orange, PVC cable EVT064
Socket, M12, 4-pole,5 m orange, PVC cable EVT004
Socket, M12, 4-pole,2 m orange, PVC cable EVT067
Welding adapter,Ø 50 mm E30122
74
LR9020 level transmitter withingress-resistant housing andIO-Link parameter setting
Robust and reliableThe LR9020 reliably resists harsh environmental conditions or high-pressure cleaning. Its small design allows installa-tion in restricted spaces. The digital IO-Link communication prevents disturbancein measured value transfer.
Successful thanks to modular conceptThe probes can be shortened, or changed, so the LR reduces stock-keeping and simplifies replacement.
User-friendly settingEven before installation the user can set the sensor parameters via IO-Link on the PC. The data record ofparameter setting can be copied to other sensors, e.g. for installations of identical design.
Analogue output, switching output andprocess value transfer via IO-Link
User-friendly parameter setting via IO-Linkby means of PC or IO-Link master
Probe lengths of 10...160 cm
The probe can be cut to length, if needed
Small design for limited space
Continuous level measurementwith analogue output and IO-Link
Process sensors
75
(04.2015)
Level sensors
Accessories (to be ordered separately)
Type DescriptionStainless steel (303/1.4305)
Orderno.
For further technical details please visit: www.ifm.com
Process sensors
Rods stainless steel (303 / 1.4305)
Coaxial pipes stainless steel (303 / 1.4305)
Flange plates
Connection technology
Applications: aqueous media, coolants, cleaning agents, oils. *
Type Description Orderno.
Socket, M12, 4-pole2 m black, PUR cable EVC004
Socket, M12, 4-pole5 m black, PUR cable EVC005
Socket, M12, 4-pole2 m black, PUR cable, LED EVC007
Socket, M12, 4-pole5 m black, PUR cable, LED EVC008
Socket, M12, 8-pole2 m black, PUR cable E11231
Socket, M12, 8-pole5 m black, PUR cable E11232Flange plate, LR 73-90 E43201
Flange plate, LR 73 - 90 / NPT E43206
Flange plate, LR 65-80 E43202
E43203240 mm
E43204450 mm
E43226300 mm
E43205700 mm
E43227500 mm
E432071000 mm
E432081200 mm
E432091400 mm
E432101600 mm
E43211240 mm
E43212450 mm
E43213700 mm
E432141000 mm
E432151200 mm
E432161400 mm
E432171600 mm
E43218450 mm
E43228300 mm
E43219700 mm
E43229500 mm
E432201000 mm
E432211600 mm
* A coaxial pipe is required for the unit to function correctly in lowdielectric media.
Process connection Set pointaccuracy
[cm]
Repeatability
[cm]
Max.tank pressure
[bar]
Protection rating/protection class
Orderno.
M12-connectorOutput function 1 x IO-Link / 1 x analogue 4...20 mA / 0...10 V · 4-wire DC PNP
G 3/4 ± 1.5 ± 0.5 -1...4 IP 69K, III LR9020
Current consumption [mA] < 80
Dielectric constant medium 2...20*> 20
Ambient temperature [°C] 0...60
Medium temperature [°C] 0...80 / (90 peak)
Metals in contactwith the medium
stainless steel(303/1.4305), PTFE, NBR
Housing materialsFKM, NBR, PBT, PC, TPE-V,
stainless steel(1.4301/304), PTFE, PEI
Power-on delay time [s] 3
Operating voltage [V] 18...30 DC
Current rating [mA] 200
Further technical data
IO-Link device type of transmission COM2 (38.4 kbaud)
G 3/4
3/4" NPT
76
Improved display and evaluation unit for Pt100 / Pt1000 sensors
One unit for many sensorsThe TR evaluation unit is a universal control and displayunit for connection of PT100 / PT1000 sensors (TT, TMand TS series)
Automatic detection of the probeThe evaluation unit automatically detects whether two-wire, three-wire or four-wire Pt100 or Pt1000 sensorsare connected.
Wide measuring rangeThanks to the extended measuring range of -100...600 °C, an enormous number of common temperature measurement and monitoring tasks in themanufacturing and process industries can be solved.And, of course, ifm also offers the corresponding temperature sensors.
Clearly indicate the acceptable ranges: programmable red/green display
Quick and easy handling via 3 pushbuttonswith VDMA menu
Visualisation of the switching states byclearly visible LEDs
Flexible installation thanks to modularconcept
Versions with analogue (4...20 mA /0...10 V) or switching output (2 x PNP/NPN)
Evaluates temperatures up to 600 °C: the TR with a new look
Process sensors
77
(11.2015)
Temperature sensors
For further technical details please visit: www.ifm.com
Process sensors
Dimensions
6448
M12
x1
34
104
3
16,5
2
1
30
Connection technology
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Mounting clamp, Ø 34 mm,PBT E10017
Mounting clamp, Ø 34 mm,PA E10193
Protective cover for fluid sensors with M12 connector,polypropylene homopolymer
E30420
Accessories
Type Description Orderno.
Response dynamicsT05 / T09
[s]
Pressure resistance
[bar]
depends on the connected sensor
Measuring range
[°C]
Factory setting
[°C]
Orderno.
Output function 1 x NO / NC programmable · 1 x analogue output 4…20 mA or 0…10 V programmable
-100...600 -40...300
Process connection
G 1/2 A TR2439
depends on the connected sensor
Output function 2 x NO / NC programmable
-100...600 -40...300 G 1/2 A TR7439
Accuracy [K] ± 0,3 + (± 0,1 % MS)
Electrical design PNP / NPN
Protection IP 67
Communication interface IO-Link
Resolution display [K] 0,1
Operating voltage [V] 18...32 DC
Current rating [mA] 250
Further technical data
IO-Link accessories
Type Description Orderno.
Temperature sensors for connection to the TR type
VersionHigh-temperature cable sensor
Orderno.
2 m, PFA / PTFE cables TS2451
2 m, PFA / PTFE cables TS2452
2 m, PFA / PTFE cables TS2453
2 m, PFA / PTFE cables TS2454
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumptionfrom USB port: max. 500 mA
E30396
Memory plug, parameter memoryfor IO-Link sensors E30398
LINERECORDER SENSOR,software for parameter setting and setting up IO-Link sensors
QA0001
USB IO-Link master for parameter settingand analysis of unitsSupported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
Installation length[mm]
100
150
200
250
1) LEDs (display unit / switching status)2) 4-digit alphanumeric display / alternating indication of red and green3) Programming buttons
78
Even easier to use and withimproved visualisation
Quick and resistantThe compact TN type temperature sensors are distinguished by excellent response times, high pressureresistance and adaptive process connections. The sensors easily resist applications with temperatures upto 150 °C and high pressure loads up to 300 bar. Themeasuring range is freely scalable.
Updating a classicWhat is new is the quick and easy handling via threepushbuttons. The display can be switched from the indication of ”red“ to an alternating indication of “red - green“. So, switching states can be highlighted or an independent colour window can be created. The sensor head can be rotated and offers optimum readability from any position. Thanks to captive laser labelling on the stainless steel housing, the units can still be identified after years.
Measuring range of -50...150 °C, response time T05 / T09 = 1s / 3s.
Clearly indicates the acceptable ranges: programmable red/green display
Quick and easy handling via 3 pushbuttonswith VDMA menu
Versions with analogue (4...20 mA /0...10 V) or switching output (2 x PNP/NPN).
Visualisation of the switching states byclearly visible LEDs
Modern classic: new TN temperature sensor
Process sensors
79
(11.2015)
Temperature sensors
Dimensions
34
140
4
3
1445
2
110
048
M12
x1
30
6
22
For further technical details please visit: www.ifm.com
Process sensors
Connection technology
Type Description Orderno.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
Mounting clamp Ø 34 mm,PBT E10017
Mounting clamp Ø 34 mm,PA E10193
Progressive ring T-pieceStainless steel (320S17) E40102
Adapter, M18 x 1.5 - L18, high-gradestainless steel (316L/1.4404), FKM E40104
Adapter, M18 x 1.5 - G 1/2High-grade stainless steel (316L/1.4404) E40096
Adapter, M18 x 1.5 - G 1/4High-grade stainless steel (316L/1.4404) E40099
Protective cover for fluid sensors with M12 connector,polypropylene homopolymer
E30420
Accessories
Type Description Orderno.
Response dynamicsT05 / T09
[s]
Pressure resistance
[bar]
300 1 / 3
Measuring range
[°C]
Factory setting
[°C]
Orderno.
Output function 1 x NO / NC programmable · 1 x analogue output 4…20 mA or 0…10 V programmable
-50...150 -40...150
Process connection
M18 x 1.5 I TN2511
300 1 / 3
Output function 2 x NO / NC programmable
-50...150 -40...150 M18 x 1.5 I TN7511
Accuracy [K] ± 0.3 + (± 0.1 % MS)
Electrical design PNP / NPN
Protection IP 67
Communication interface IO-Link
Resolution display [K] 0.1
Operating voltage [V] 18...32 DC
Current rating [mA] 250
Further technical data
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumptionfrom USB port: max. 500 mA
E30396
Memory plug, parameter memoryfor IO-Link sensors E30398
LINERECORDER SENSOR,software for parameter setting and setting up IO-Link sensors
QA0001
IO-Link accessories
Type Description Orderno.
USB IO-Link master for parameter settingand analysis of unitsSupported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
1) LEDs (display unit / switching status), 2) 4-digit alphanumeric display / alternating indication of red and green, 3) Programming buttons, 4) Upper part of the housing can be rotated by 345°
80
Process sensors
Compact design with excellentresponse time and extendedmeasuring range
Analogue and IO-LinkThe temperature transmitter has an analogue outputwith 4...20 mA. The parameters are set via the integrated IO-Link interface.
Fast and preciseThe Pt1000 measuring element of class A achieves ahigh precision with the factory-internal calibration. The innovation besides the wide measuring range is theexcellent response time. Therefore the sensor is suitablefor all highly-precise and fast processes in hygienic environments.
Transparent and flexibleAn LED clearly signals the readiness for operation.Compact design, integrated process connections anddifferent probe lengths enable easy and flexible installa-tion.
Measuring range of -50...200 °C, scalablevia IO-Link 1.1
Very fast response time: T05 / T09 = < 0.5 s / < 2 s
LED for visualisation of the operating status
Versions with different hygienic processconnections
Different installation lengths from25...150 mm
200° below 2 s : fast, hygienictemperature transmitter
81
(04.2015)
Process sensors
For further technical details please visit: www.ifm.com
Temperature sensors
Installation length
[mm]
Orderno.
Process connection Clamp 3/4“Temperature range (scaled 4...20 mA) -50...200 °C
Process connection Clamp 1.5“Temperature range (scaled 4...20 mA) -50...200 °C
Operating voltage [V DC] 18...32
Protection IP 67, IP 68, IP 69K / lll
Materials in contact with the medium
High-grade stainless steel(316L/1.4404)
Further technical data
Reverse polarity / overload protection • / •
Measuring element Pt1000, class A
Response dynamics T05 / T09 < 0.5 s / < 2 s
Accuracy [K] ± 0.3 + (± 0.1 % MS)
Measuring range [°C] -50...200
Ambient temperature [°C] -25...80
IO-Link revision 1.1
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumptionfrom USB port: max. 500 mA
E30396
Memory plug, parameter memoryfor IO-Link sensors E30398
LINERECORDER SENSOR,software for parameter setting and setting up IO-Link sensors
QA0001
Accessories
Type Description Orderno.
Dimensions
6
M12
x118
,7
15,9 50,4 EL
LED 2 x 180° 1
L+
L3
1
4
2IO-Link
L+
L
1
2
Wiring diagram
Example TA2002
Connection technology
Type Description Orderno.
TA2002
TA2012
TA2802
TA2812
TA2832
TA2842
G 1/2 process connection with sealing coneTemperature range (scaled 4...20 mA) -50...200 °C
TA2502
TA2512
TA2532
TA2542
Process connection ø 6 mmTemperature range (scaled 4...20 mA) -50...200 °C
TA2212
TA2232
TA2242
1) 3/4" Clamp
Socket, M12, 4-pole,5 m orange, PVC cable EVT001
Socket, M12, 4-pole,10 m orange, PVC cable EVT002
Socket, M12, 4-pole,5 m orange, PVC cable EVT004
Socket, M12, 4-pole,10 m orange, PVC cable EVT005
25
60
30
50
100
150
30
50
100
150
50
100
150
82
Process sensors
Compact temperature transmitter with excellent response time and IO-Link 1.1
VersatileThe TA type temperature sensor is a universal transmitter with a 4...20 mA current output which can be scaledover the -50 to 150 °C measuring range. Scaling is done simply via the integrated IO-Link interface
FlexibleThe compact design, the integrated process connections and a multitude of probe lengths enable particularlysimple installation.
TransparentAn integrated LED clearly signals the readiness for operation.
Fast and preciseA high level of accuracy is achieved using a class A accuracy Pt1000 sensor and factory calibration. In addition, ifm’s tried and tested film technology ensures excellent dynamic response times. So this sensor is suited for all highly precise and rapid processes.
Space-saving in all installation positions
LED for visualisation of the operating status
Fast response time: T05 / T09 = 1 s / 3 s
Pressure resistant up to 400 bar
Different installation lengths from25...150 mm
Small but effective: temperaturetransmitter in compact housing
83
(11.2014)
Process sensors
For further technical details please visit: www.ifm.com
Temperature sensors
Operating voltage [V DC] 18...32
Protection IP 67, IP 68, IP 69K / lll
Materials (wetted parts) high-grade stainless steel(316L/1.4404)
Further technical data
Reverse polarity / overload protection • / •
Measuring element Pt1000, class A
Response dynamics T05 / T09 1 s / 3 s
Accuracy [K] ± 0.3 + (± 0.1 % MS)
Measuring range [°C] -50...150
Ambient temperature [°C] -25...80
IO-Link revision 1.1
IO-Link interface for parameter settingand analysis of units with DTM specification, current consumption via USB port: max. 500 mA
E30396
Memory plug, parameter memory for IO-Link sensors E30398
LINERECORDER SENSOR, software for parameter setting and set-up of IO-Link sensors
QA0001
Accessories
Type Description Order no.
Dimensions
Wiring diagram
Connection technology
Type Description Order no.
Socket, M12,2 m black, PUR cable EVC001
Socket, M12,5 m black, PUR cable EVC002
Socket, M12,2 m black, PUR cable EVC004
Socket, M12,5 m black, PUR cable EVC005
6
M12
x118
,7
15,9 48 14
26LED G ½
EL
L+
L3
1
4
2IO-Link
L+
L
1
2
TA24
6
M12
x118
,7
15,9 48
19
13
G ¼LED
ELTA21
Nominal length
[mm]
Order no.
Factory setting
Pressure resistance
[bar]
Process connection G 1/2Analogue output scalable 4...20 mA
30 300
50 300
100 160
150 160
Process connection G 1/4Analogue output scalable 4...20 mA
25 400
50 400
100 160
150 160
TA2405
TA2415
TA2435
TA2445
TA2105
TA2115
TA2135
TA2145
Thermowells
G 1/2 E37600
G 1/2 E37610
G 1/2 E37620
G 1/2 E37640
27
74
124
224
50
100
150
250
Screw-in thermowell, process connection G 1/2
-50...150 °C
-50...150 °C
Process connection G 1/2Analogue output scalable 4...20 mA
50 300
100 160
150 160
TA2417
TA2437
TA2447
0...100 °C
27
G ½
G ½
28 ELBL
1
97
Dimensions
Device connection
Installation depth EL [mm]
Sensor Thermowell
Orderno.
84
Process sensors
Thermowells for all common process connectionsand installation depths
Why is a thermowell required?Aggressive media, high pressures and flow speedsmake the use of thermowells necessary. Thermowells protect temperature sensors from such influences and make it possible to replace sensors inthe running process. So, a calibration of the sensors is possible at any time.
UniversalThe ifm thermowells are suited for all temperature probes with a diameter of 6 mm. Market common process connections are designed for use in hygienicand industrial applications.
Convenient: sensor calibration withoutprocess interruption
Special: for industrial and hygienic applications
Robust: sensor protection in harsh applications
Suited: for all Ø 6 mm temperature probes
Flexible: installation depths of 30...330 mm
Extra protection for temperature sensors
85
(11.2014)
Process sensors
For further technical details please visit: www.ifm.com
Temperature sensors
Device connection
Installation depth EL [mm]
Sensor Thermowell
G 1/2 E37810100
G 1/2 E37820150
G 1/2 E37830250
G 1/2 E37850350
Orderno.
G 1/2 E37910
G 1/2 E37920
G 1/2 E37930
G 1/2 E37950
G 1/2 E37430250
G 1/2 E37450350
Ø 6 mm E37603
Ø 6 mm E37613
Ø 6 mm E37623
Ø 6 mm E37643
Ø 6 mm E37663
G 1/2 conical E37511
G 1/2 conical E37521
G 1/2 conical E37411
G 1/2 conical E37421
G 1/2 conical E37431
G 1/2 E37600
G 1/2 E37610
G 1/2 E37620
G 1/2 E37640
64
115
191
267
191
267
33
83
128
233
333
68
118
49
99
149
27
74
124
224
50
100
150
250
350
100
150
50
100
150
50
100
150
250
Process connection Tri-Clamp 1.5" for type: TA24, TT12, TT32, TM44, TD22
Process connection Tri-Clamp 2" for type: TA24, TT12, TT32, TM44, TD22
Welding thermowell, weld-in process connection for type: TT32, TD22
Clamp fitting, process connection G 1/2 for type: TT92, TT02, TT12, TT22, TT32, TD22
Hygienic thermowell, process connection G 1/2 conical for type: TM45, TD25
Welding clamp adapter, ball process connection 34 mm Ø for type: TM45, TD25
Screw-in thermowell, process connection G 1/2 for type: TA24, TT02, TT12, TT22, TT32, TM44, TD22
63
ELBL
6,4
44,5
12,7
6,6
19
38,1 1
26,7
½" NPS
63
ELBL
6,4
44,5
12,7
6,6
19
38,11
26,7
½" NPS
38,1
44,5 ELBL
6,4
6,6
16
½" NPS
7 9
27 G ½
ELBL
13
1M4
27
G ½
G ½
97 18
72 ELBL
2,5
37
2,5
41 ELBL
G ½
793034
16,6
27
G ½
G ½
28 ELBL
1
97
1) 1.5" Clamp (ISO 2852)
1) 2" Tri-Clamp (ISO 2852)
100
150
250
350
64
115
191
267
86
Safe automation system includes PLC and gatewayfunctions
All-in-one: more than just a PLCJust as a smartphone is more than just a phone, thenew SmartPLC is more than just a simple PLC. It has the flexibility for different tasks, even in safety-related applications up to SIL 3, PL e. For example as:– fail-safe PLC– standard PLC– AS-i gateway– visualisation system– protocol converter– data logger– intelligent evaluation unit (ifm system solutions)Two integrated PLCs (1 x fail-safe, 1 x standard),powerful processors, a large memory and a multitude of supported protocols allow the control of sophisticatedsystems – and this at an unbeatable price!
Quick and easy set-up
Flexible and future-proof thanks to connective hardware and CODESYS V3
High machine uptime due to sophisticateddiagnostics
Unbeatable price/performance ratio
Safe up to SIL 3, PL e
Safety 4.0: the safe SmartPLC
Industrial communication
87
(11.2015)
Products
Orderno.
AS-i Profinet gateway with safe preprocessing AC402S
AS-i EtherNet / IP gateway with safe preprocessing AC422S
Dimensions
106,293
135,
512
8,2
AS-Interface Safety at WorkIndustrial communication
Type Description
AS-i gateway
For further technical details please visit: www.ifm.com
Accessories
Orderno.
AS-i data decoupling module AC1250
Type Description
Safe PLCCertified up to SIL3, PL e. Eight safe local inputs andfour safe local outputs. Convenient diagnostic functions, e.g. status indication for safe I/Os and error memorywith time stamp for up to 2,000 messages. Programming is done via CODESYS V3. Simplified replacement of slaves using automatic teach function.
Standard PLCThe PLC can be freely programmed using CODESYS V3.Its software and hardware operates independently ofthe fail-safe PLC, but it can of course communicatewith it and exchange data. The PLC has access to all interfaces of the system.
AS-i gatewayWithout programming, the SmartPLC can be used directly as a gateway for AS-i on the one side, and Profinet or EtherNet/IP on the other side. The integrateddisplay and the convenient web interface display all theavailable status information for the user and supportdiagnostics in case of a fault.
Data loggerOperational system data can be recorded via AS-i,EtherCAT, Modbus TCP, Profinet, EtherNet /IP, TCP/IP,UDP/IP and stored on the SD card or in the internalflash memory. If needed, the integrated real-time clock provides atime stamp for each recorded data block. This simplifiesthe documentation and diagnostics of processes.
Visualisation systemA freely programmable web visualisation based onHTML5 provides maximum transparency. An internetbrowser with HTML5 capability is sufficient on the finalunit (PC, tablet, smartphone). No further software is required. Even the full graphic display of the SmartPLCis freely programmable for visualisation tasks.
Platform ifm system solutionsWith the new ifm system solution apps, the processdata of different sensors is transmitted to commonfieldbus systems and their parameters are easily madeaccessible. These tailored apps can be loaded onto theSmartPLC without programming software. This makesyour installation fit for Industry 4.0.
Protocol converterConnect your sensors and Ethernet based devices toyour fieldbus: the SmartPLC can be used as protocolconverter between Profinet, EtherNet /IP on the oneside and AS-i, EtherCAT, Modbus TCP, TCP/IP, UDP/IPand IO-Link on the other side.
All-in-oneThe new SmartPLC combines two separate PLCs in one compact housing. While the one PLC solves safety-related applications, the second PLC either works as astandard PLC or as platform for other tasks. Both PLCs communicate with each other, so that entireplant controls can be implemented including safetyfunctions and visualisations with only one SmartPLC.
88
Safe bus connection for light guards
Safe AS-i input module especially for light guard applications
Module for light gridsUsing this new, safe input module, light guards andother safety-related sensors with electronic OSSD out-puts can be connected to AS-i Safety at Work.
Control muting lampThe integrated outputs ensure the connection of twosignal lamps.
Quick mounting without toolsThe tried-and-tested quick mounting avoids wiringfaults. There is one M12 connecting socket each for thetransmitter, the receiver and the two signal outputs.
Two alternatives for the voltage supplyDepending on the design, the light guard and the signal lamps can be completely supplied via AS-i or anexternal auxiliary voltage.
Optimised M12 socket connection for light guard applications
Muting lamp can be controlled by PLC
Precise and flexible quick mounting
Supply of the light guards from AS-i
High safety due to certification to EN 62061/SIL3 and EN ISO 13849-1/ PL e
With signal effect: AS-i modulefor OSSD inputs
Industrial communication
89
(11.2015)
The products
Orderno.
Advantages and customer’s benefitsFail-safe sensors with a current consumption below 200 mA can be operated on AC507S without auxiliaryvoltage. Connection is only made via the yellow AS-iflat cable.
AS-i quick connectionThe quick-connection technology provides a high degree of installation reliability and flexibility. The AS-i flat cable can be connected from three different directions.
Diagnosis on siteThe LEDs indicate the status of the inputs and outputsand the communication.
SafetyThe module meets the requirements up to SIL3 according to EN 62061 and PL e to EN 13849-1. In the event of afault, the integrated communication monitoring switches the signal outputs off.
ApplicationsThe module is designed for the connection of electro-sensitive protective equipment (ESPE) with electronicoutputs to EN 61496-1. It is particularly suited for theconnection of safe inductive sensors such as GM705S.Pulse pick-ups for the display of muting functions canbe connected via M12 sockets.
Operating voltage (AS-i) [V DC] 26.5...31.6
Short-circuit protection •
Overload protection •
AS-i profile S-7.B.E
AS-i specification 2.11 + 3.0
Extended addressing mode –
Ambient temperature [°C] -25...55
Protection IP 67
Safe AS-i input modulesAC507S, AC508S
Technical data
Type Description Order no.
Safe AS-i input module
Sensor supply Inputs / outputs: via AS-iCurrent rating inputs / outputs: 200 mA in totalTotal current consumption: ≤ 280 mA
AC507S
Sensor supply Inputs / outputs: 24 V external, PELVCurrent rating inputs / outputs: inputs 200 mA, outputs 500 mATotal current consumption: < 80 mA
AC508S
AS-Interface Safety at Work
For further technical details please visit: www.ifm.com
Dimensions
45
103
40,244,7
25,8
Industrial communication
Adapter cable,from 8 poles to 5 poles,M12 plug / M12 socket,configured for automatic operation
EY3090
Adapter cable,5 poles,M12 plug / M12 socket,configured for "short range"
EY3092
Adapter cable
90
Connection of IO-Link sensorsto all field buses
PLC
Fieldbus modules for all controllersThe 8-port IO-Link masters are field-compatible input /output modules for the connection of up to 8 IO-Linkdevices, for example sensors, valves or binary input /output modules. Process signals, events and parametersare transferred to the controller via PROFINET, EtherCat,Ethernet/IP or PROFIBUS.
Connection of sensors and actuatorsUp to 8 IO-Link sensors can be connected. Four of theeight ports are designed as B ports and supply auxiliaryenergy for the connection of IO-Link actuators. The total current consumption per module can total upto 12 A.
Robust field deviceThe modules allow use in a wide temperature range of -25...60 °C. The high EMC and the robust mechanicsguarantee high availability even in difficult environments.
8 IO-Link ports with full V1.1 functionality:COM1, COM2, COM3 and SIO mode
4 additional binary inputs
2 Ethernet ports 10/100 Mbits/s withswitch for the field bus connection
Protection IP 65 and IP 67 with full potting,all connections via M12 plug-in
An integrated parameter memory facilitates device replacement
8-port IO-Link master: closing the gap in the field
Industrial communication
IO-Link: Data highway to the sensor
91
(04.2015)
The products
Fieldbus,PROFINET AL1000
Fieldbus,PROFIBUS AL1010
Fieldbus,EtherNet/IP AL1020
Fieldbus,EtherCAT AL1030
Total current consumption [A] 12
Operating voltage [V DC] 18...31.2
IO-Link version 1.1
Number of IO-Link ports 8
Number of binary inputs 4 + 8 (IO-Link in SIO mode)
Ambient temperature [°C] -25...60
Housing materialPA;
Socket: Nickel-plated brass
Protection IP 65, IP 67
Parameter memory •
Port A /port B 4 / 4
IO-Link master field modules
IO-Link componentsIndustrial communication
Technical data
Unit versions
For further technical details please visit: www.ifm.com
Advantages and customer benefits
• 12 amperes on an M12 connectorThe module supply and the auxiliary power are supplied via the T-coded M12 connector. The energy can belooped through the module (daisy chain).
• Easy sensor connectionThe sensors and actuators are connected via standardM12 connection cables without screening.The cable may be up to 20 m long.
• Reliable digital dataThe sensor data is transferred digitally. Contact resistance and EMC interference cannot falsify the signals.
Dimensions
Orderno.
Type Description
2030,5
1,5
M12
x1
LEDs
6030
198,
518
5
212
8,56
AL1000
92
Effective connection of binarysensors to any IO-Link master
Field modules with IO-Link connectionUp to 8 or 16 conventional sensors can be connected to these modules. IO-Link transfers the signals to anyIO-Link master / PLC via one unscreened M12 connection cable. Wiring costs are reduced because there are nolonger any complex cable trees. As opposed to bus systems IO-Link does not require anyconfiguration or addressing. This simplifies installation.
Two binary inputs per M12 socketPin 4 and pin 2 of each socket are used for one input.That means that dual sensors, normally closed or normally open, can be connected without any problem.
Robust field deviceThe modules allow use in a wide temperature range of -25...70 °C. The high EMC and the robust mechanicsguarantee high availability even in difficult environments.
Up to 8 locations with two binary inputs each
Unscreened standard M12 cable sufficientfor data and energy transmission
High protection rating IP 67
Robust due to full potting
IO-Link I/O module minimises wiring costs for sensors
Industrial communication
Wire 16 signals with three wires.
93
(04.2015)
Dimensions
IO-Link version 1.1 and 1.0
Operating voltage [V DC] 18...30
Type of transmission COM2 (38 kBaud)
Ambient temperature [°C] -25...70
Short-circuit protection •
Overload protection •
Protection IP 67
Min. cycle time process data [ms] 2.3
IO-Link input modules
IO-Link componentsIndustrial communication
Technical data
For further technical details please visit: www.ifm.com
Advantages and customer benefits
• IO-Link replaces multi-pole cableMulti-wire cables and connectors are a matter of the past. Standard M12 connections between theinput module and an IO-Link master transfer up to 16 binary input signals.
• Support of interchangeable toolsThe tree-wire connection minimises complex cablingfor interchangeable tools.The input modules can store a tool number so thatthe PLC can easily identify and differentiate tools.
M12 sockets 4
Number of binary inputs 4 x 2
Total current consumption [mA] ≤ 450
8
8 x 2
≤ 850
Current rating [mA]for all inputs, total 400 800
Unit versions
Order no. AL2400 AL2401
2327
54,
5
M12x1
M12x1
X1.0
4,7
107
118,
2
28,539
7,5
60
X1.1
X1.2 X1.3
AL2400
23274,
710
715
2
28,539
7,5
60
54,
5
M12x1
M12x1X1.0 X1.1
X1.2 X1.3
X1.4 X1.5
X1.6 X1.7
AL2401
94
Easy communication with thePLC and in parallel to the LINE-RECORDER SMARTOBSERVER*
Interface for factory networkingWith the integrated LINERECORDER AGENT, this masterenables direct networking of all connected IO-Link devices with a local server via an Ethernet network.Using this connection, machine data, process parameters and diagnostic data can be directly read and processedby the IT. The easy-to-use server software LINERECORDER SMARTOBVSERVER* enables data evaluation by meansof customer-specific cockpits. Using the same communication mechanisms, it is possible to directly couple machines and exchange production-related data.
From sensor to SAPFor the first time, sensor data can be directly transmitted to management software - and this on a factory-wideor even worldwide level. Evaluation of the obtained data in real time enables anincrease in production efficiency and energy savings inthe context of Industry 4.0.
The IO-Link master module for different applications:from machine condition monitoring to remote maintenance of wind parks.
*LINERECORDER SMARTOBSERVER is a server-based software for data storage, predictive maintenance and quality monitoring.
8 IO-Link ports V1.1 with COM1, COM2,COM3 and SIO support
10 extra binary inputs 24 V DC and 2 configurable binary inputs/outputs
2 Ethernet ports 10/100 Base-TX with integrated switch
Slim housing for control cabinet mounting
Extended temperature range of 0...70 °C
8-port IO-Link master module with LINERECORDER AGENT embedded
Industrial communication
95
(04.2015)
System solutionsIndustrial communication
For further technical details please visit: www.ifm.com
Special features
Ethernet interface for PLC connectionThis IO-Link master operates as an input/output cardwith a total of 20 I /Os, of which 8 are for IO-Link devices and the rest for binary signals.All signals can be easily transmitted to compatible controllers via the standard fieldbuses EtherNet /IP orProfinet.Two ways simultaneously = PLC and server in parallelSo far, all sensor signals had to be sent by the PLC to higher-level systems. This is now done via a parallelcommunication path (Y path). The PLC program remains unchanged.Integrated web server for configuration and diagnosticsNo special software is required for configuration. All IO-Link settings can be made via the integrated web interface. To do so, a standard PC with Ethernet connection and web browser is required.Convenient IODD integrationVia the web interface, up to 8 different IODDs (IO-Linkdevice descriptions) can be loaded into the master. After connection of the IO-Link devices, the correspondingIODDs are automatically assigned to the connected IO-Link devices and the corresponding ports.
Parallel sensor communication
IO-Link master IO-Link master
PLC
industrial fieldbus
LR agent communication (option)
LINERECORDERweb-baseduser interface
IO-Linksensors
· · ·1 2 7 8
server
IO-Link
IO-Linksensors
· · ·1 2 7 8
Technical data
“Y“ path for PLC data exchange and a parallel connection to the server via LINERECORDER AGENT
IO-Link master module for connection to fieldbuses
Fieldbus connection EtherNet/IP Profinet
Further protocols Modbus / TCP (slave)
Order no. AY1020 AY1000
Supply voltage [V] 18...30 DC
Current consumption [A] 2 (24 V)
IO-Link version 1.1
Number of IO-Link ports 8
Parameter memory •
IO-Link port A / port B up to 8, configurable
Inputs/outputs IO-Link / SIO configurable
IO-Link baud rates COM 1...3 4.8k, 38.4k, 230.4kBaud
Digital inputs max. DI 8 (16) +2
Digital outputs max. DO 8 + 2
IO-Link / DI / DO status LEDs 20
Ethernet connections 2x (10/100 BASE-Tx)
Module / Ethernet status LEDs 7
Ethernet sockets RJ45
Electrical connections screw terminals
Protection IP 20
Housing material polyamide plastics
Ambient temperature [°C] 0...70
Installation DIN rail
96
Short overview of the most important ideas and advantages of IO-Link
IO-Link = universal process data interfaceIO-Link masters are universal input/output modules.Different types of units can be operated on the sameport: IO-Link sensors, IO-Link actuators and units withswitching signal. Therefore, one IO-Link port can replace several components: analogue (4...20 mA, 0...10 V) and binary input and output cards.
IO-Link = smart sensor interfaceIn smart sensors, IO-Link is already integrated. So, datacan be exchanged bidirectionally with the controller,e.g. diagnostics and maintenance messages or data forremote parameter setting.
IO-Link = easy set-upThe easiest way to obtain sensor process values is aseasy as the connection to an analogue card. Connectthe sensor to the IO-Link master – done.Replacement is just as easy. All sensor parameters arestored in the master and transferred to the new unit.
Smart IO-Link sensors can be conveniently set using theLINERECORDER SENSOR 4.0 software.The sensor settings can be stored, copied, loaded orcloned to other units.
The USB IO-Link interface establishes the connectionbetween IO-Link units and the LINERECORDER SENSOR.It is compatible with most Windows PCs.
IO-Link masters are available for all majorPLCs and fieldbuses
Simple configuration via LINERECORDERSENSOR (PC) or via web interface
IO-Link app for AS-i gateways withautomatic network scan of all sensors
A wide range of ifm sensors with IO-Link:encoders, capacitive, photoelectric, temperature, flow, pressure and level sensors
IO-Link – The standard interfacefor smart sensors
Industrial communication
97
(04.2015)
System solutionsIndustrial communication
For further technical details please visit: www.ifm.com/gb/io-link
10 good reasons to use IO-Link
Fast and easy set-up and service:1. Offline parameter setting of the sensors prior to
installation.2. Automatic sensor detection online when using the
IO-Link app on the AS-i/fieldbus gateway.3. Easy sensor replacement with automatic parameter
setting by the master.Sensor identification included.
High machine uptime:4. Avoidance of incorrect handling during operation
by deactivating the operating keys on the sensor.5. Easy transmission of the measured values without
conversion losses; values on the sensor displaycorrespond to the values on the machine display.
6. Highly interference immune - because digital -analogue value transmission in comparison withconventional analogue technology. And this usingan unscreened cable without special grounding.
7. Machine diagnostics up to the sensor level functions without disrupting the operation.
Less wiring saves installation costs:8. Several analogue signals and switch points can be
transmitted using only one standard 3-wire cable.This reduces the number of terminals and makesspace in the cable duct.
9. Sensors and actuators, analogue or binary, can beconnected via IO-Link ports. This replaces differentinput/output modules.
Investment security:10. IO-Link has been internationally standardised to
IEC 61131-9 and is therefore future-proof. Theacceptance of all leading automation suppliersensures investment security for OEMs and users.
IO-Link is the interface to Industry 4.0.
Typical plant configuration
IO-Link masterIP20
IO-Link masterIP67
sensor parameter settingPLC
industrial fieldbus
LINERECORDERsensor 4.0
MODBUS-TCP
IO-Linksensors
· · ·1 2 7 8
IO-LinksensorwithIO-Link
IO-Link
IO-Linksensors
· · ·1 2 7 8
USBadapter
Order data
Technical data
IO-Link service & maintenance tools
Characteristic IO-Link data
IO-Link USB master low power E30396
IO-Link USB master ext. power E30390
LR Sensor 4.0 parameter setting softwarewith IODD import QA0001
Analogue converter -50...300 °CPt100/Pt1000 to IO-Link TP3232
Analogue converter 0...100 °CPt100/Pt1000 to IO-Link TP3237
IO-Link app for AS-i gateways AC14xx AP3001
Analogue converter -50...150 °CPt100/Pt1000 to IO-Link TP3231
Memory plug - sensor-parameter memory E30398
Cable length [m] 20
Line physics type A 3-wire cable,unscreened
Connection M12, M8, M5, terminals
Process data (PD) per device 1 bit ... 32 bytes
Cycle time for 2 bytes [ms] 2.3
Parameters, diagnostics and events acyclic transmission
Power supply type APower supply type B
sensors 200 mAsensors + actuators
separated
M12 pin connection type A
pin 1: 24 V DCpin 3: 0 V DCpin 4: IO-Link /
binary input / output
Description Orderno.
98
Easy as using a smartphone!Individual connection to a PLCby means of reloadable apps
Until now: complex programmingModern sensors offer more and more intelligent functions that can also be made available to the PLC via interfaces like IO-Link or TCP/IP.To use them, the PLC programmer has to individuallyimplement the functionalities in the PLC. This is verytime-consuming and costly, especially when it comes to implementing the required user interfaces.
From now on: fit for Industry 4.0 – ifm System SolutionsWith the new ifm System Solution Apps ifm electronichas developed a system which is easy to create. It allows process data from different sensors to be transmitted tocommon fieldbus systems, and their parameters are easily accessible. For this purpose, ifm now offers tailored apps whichcan be loaded into the ifm fieldbus gateway withoutany programming software.
Fast and easy integration of intelligentsensors into the PLC world
No special PC software required, an internet browser is sufficient
PLC connection via the fieldbus protocolsProfinet, Profibus, EtherNet/IP and others
Smart additional functions tailored to thesensors selected
Straightforward web configuration instead of time-consuming and costly programming
Industry 4.0 made easy – Apps instead of expensive programming
Industrial communication
99
(11.2015)
The products
Orderno.
System solutionsIndustrial communication
ifm System Solution Apps
For further technical details please visit: www.ifm.com
ifm System Solution AppsThe centrepiece for using the ifm System Solution Appis the AC14 SmartPLC. On the one hand, the devicehas a certified fieldbus interface (Profinet, Profibus, EtherNet/IP) for the connection to a PLC. On the other hand, the AC14 features excellent communication possibilities via an additional EtherNetinterface and up to two AS-i masters for connection toa variety of sensors and actuators.Loading and configuration of the app is made via theintegrated web interface, i.e. all necessary settings canbe carried out conveniently via a device with an inter-net browser.
System overview
Example: ifm System Solutions App for O3D camera
Web-based configuration
PLCworld
Sensorworld
www.ifm.comSystem Solution Apps
AC14
analogue signalsbinary signals
Ethernet
TCP/IPUDP/IP
Web-based configuration
AC14 with App for O3D camera
PLCworld
Sensorworld
PLC TCP/IP
O3D camera
IO-Link scanner and configurator AP3002
Field bus connection of up to five type O2I multi-code readers to Profibus, Profinet, EtherNet/IP AP3022
Field bus connection of up to three type O3D200 multi-code readers to Profibus, Profinet, EtherNet/IP AP3032
AS-i based DTA ID systems: user-friendly writing of RFID tags, history data AP3042
Data collector: up to 30 process data can be freelynamed and scaled, history data with time stamp can be stored on SD card, fieldbus connection to Profibus,Profinet and EtherNet/IP
AP3052
Tool changeover: via the fieldbus (Profibus, Profinet, EtherNet/IP) free selection of predefined AS-i configurations
AP3062
100
All in one unit: antenna, evaluation and CANopen interface
RFID compact units suitable for mobile useThe robust RFID compact units with CANopen interfacehave been developed for identification tasks in agricultural machines, municipal vehicles and construction machines.It automatically detects different attachments and configures the corresponding settings in the controller.This automatic identification simplifies the creation ofuser-specific system set-ups.Information on maintenance intervals and operatingtimes can automatically be generated and stored sincethe controller automatically detects when and howlong a specific machine set-up runs.Downtimes are minimised, productivity is increased.
Optimised for outdoor use with IP 67 andIP 69K
Extended temperature range of -40...85 °C
E1 type approval
Shock resistant to EN60068-2-27 and vibration resistant to EN60068-2-64
Optimised for use with ifm ecomatmobilecontrollers
RFID for mobile machines
Identification systems
101
(11.2015)
RFID 125 kHz / RFID 13.56 MHz
When competences complement each otherifm develops and produces RFID evaluation units andantennas for industrial applications.These RFID systems are available for all common frequency ranges.Even the integration of different fieldbuses into theRFID components has been successfully implemented.Furthermore, ifm as an automation specialist has know-how of many years in the area of mobile machines,where control systems and sensors from ifm have beenestablished in the market.The competences and experience of these both different areas have now been combined in the RFID solution formobile machines.
For further technical details please visit: www.ifm.com
Identification systems
Description Orderno.
E80370ID tag/30X2.8/03 – 13.56 MHz, 16 Kbits – FRAM
E80371ID tag/30X2.5/06 – 13.56 MHz, 896 bits
E80377ID tag/R20X2.5/06 – 13.56 MHz, 896 bits
RFID evaluation unit / RFID antenna
The products
E80380ID tag/30X2.8/03 – 13.56 MHz, 64 Kbits
E80381ID tag/4.35X3.6/03 – 13.56 MHz, 896 bits, 10 pcs
E80382ID tag/label 65X30/03 – 13.56 MHz, 896 bits, 500 pcs
E80379ID tag/label 80X50/03 – 13.56 MHz, 896 bits, 500 pcs
Further technical data
Operating voltage [V DC] 9...32
Current consumption sensor [mA] < 50 at 24 V,< 85 at 12 V
Ambient temperature [°C] -40...85
Protection rating, protection class
IP 67 / IP 69K, III
Housing material stainless steel
Interfaces 1 x CAN
Supported CAN protocols CANopen
Standards and tests(extract)
CE, radio approval
Connection M12 connectorJumper, M12,5 m, black, PUR cable, LED EVC039
Jumper, M12,5 m, black, PUR cable EVC069
Socket, M12,2 m black, PUR cable EVM036
Socket, M12,10 m black, PUR cable EVM038
Socket, M12,5 m black, PUR cable EVC492
RFID transponders
Accessories
BasicDisplay XL, 4,3",CAN Interface CR0452
Display
Connection technology
Type Description Order no.
Type Description Order no.
DTM424M18 flush, 13.56 MHz,CANopen interface
DTM425M18 non flush, 13.56 MHz,CANopen interface
DTM434M30 flush, 13.56 MHz,CANopen interface
DTM435M30 non flush, 13.56 MHz,CANopen interface
Process and dialogue unit PDM360 NG,7" colour display CR1081
102
More flexibility in conveying due to extendedoperating distances
Reliable identificationThe new robust RFID antennas have been developedespecially for the requirements in automation and conveying technology. In combination with the antennaadapters, they ensure excellent operating distances formore reading reliability even under adverse installationconditions.The industrially compatible connection technology"ecolink" ensures quick and reliable connection of antennas and sensors to the RFID evaluation units.
Ready for Industry 4.0The ifm RFID evaluation units offer a wide range of industrial fieldbus interfaces. RFID-based identificationtasks can easily be integrated into SAP/ERP systems.
Longer ranges with patented antenna adapters
Antenna adapters for cylindrical M18 and rectangular KQ housings
Robust RFID antennas M18 for flush andnon flush installation
Extra flat antenna in rectangular KQ design for limited space conditions
Easy integration into SAP/ERP systems by means of evaluation units
Adapters to increase the rangesof the new RFID antennas
Identification systems
103
(11.2015)
RFID 125 kHz / RFID 13.56 MHz
Different interfaces
New: DTE104 with TCP/IP and SAP / ERP connectivityThis new RFID evaluation unit is ideal for direct connection to PCs, industrial PCs or PLCs that have nostandardised fieldbus interface. Users can access allconnected antennas, sensors and actuators via TCP/IPprotocol.
DTE100 system with Profibus DPRFID evaluation unit with integrated Profibus DP inter-face.
DTE101 with ProfinetThis evaluation unit is in particular intended for customers with a Siemens controller.
DTE102 system with EtherNet/IPThis version is optimised for controllers from SchneiderElectric or Rockwell Automation.
Easy integrationData access to the transponders is fast and simple, viathe provided function blocks as well as directly via theprocess image of the controller.
Integrated web serverAll evaluation units have an integrated web server.Users can log in via an HTTP address to fully access thedevice.
Antennas, digital I/O and sensorsEach evaluation unit offers four sockets to connect upto four RFID antennas. Optionally, unused RFID antennainputs can also be used for the control of outputs orthe detection of digital input signals. Two digital sensors can be connected to each socket set as an input; andan actuator to each output.
Customer benefitsThe integrated LINERECORDER AGENT simplifies the integration into SAP/ERP systems. This system solutionfacilitates the extension of the production process byadditional functions.With this version of the DTE104 the user is providedwith the ASCII protocol.
Application examplesTraceability of products plays an essential role in industry. By integrating LINERECORDER AGENT and SAP Connector the LR functions "Product Trace" and "Order Manage-ment" can be used.With RFID, materials and products can be unambiguously assigned within the production process. Here, the functions "Product Trace", "Order Manage-ment" and "Material Manager" are used.
For further technical details please visit: www.ifm.com
Identification systems
Description Order no.
DTE102RFID evaluation unit, EtherNet/IP interfac
DTE104RFID evaluation unit, Ethernet TCP/IP interface
DTE101RFID evaluation unit, Profinet interface
ANT512RFID antenna 125 KHz
ANT513RFID antenna 13.56 MHz,ISO 15693
E80370ID tag/30X2.8/03 – 13.56 MHz, 16 Kbits – FRAM
E80371ID tag/30X2.5/06 – 13.56 MHz, 896 bits
E80377ID tag/R20X2.5/06 – 13.56 MHz, 896 bits
RFID evaluation unit
RFID antennas
The products
DTE100RFID evaluation unit, Profibus DP interface
ANT515RFID antenna 13.56 MHz,1 m cable, M12 plug
ANT516RFID antenna 13.56 MHz,2 m cable, M12 plug
ANT410RFID antenna 13.56 MHz,M12 design, flush
ANT411RFID antenna 13.56 MHz,M12 design, non flush
ANT430RFID antenna 13.56 MHz,M30 design, flush
ANT431RFID antenna 13.56 MHz,M30 design, non flush
ANT420RFID antenna 13.56 MHz,M18 design, flush
ANT421RFID antenna 13.56 MHz,M18 design, non flush
E80380ID tag/30X2.8/03 – 13.56 MHz, 64 Kbits
E80381ID tag/4.35X3.6/03 – 13.56 Mhz, 896 bits, 10 pcs
E80382ID tag/label 65X30/03 – 13.56 Mhz, 896 bits, 500 pcs
E80379ID tag/label 80X50/03 – 13.56 Mhz, 896 bits, 500 pcs
RFID transponders for:ANT410, ANT411, ANT420, ANT421, ANT430, ANT431, ANT513, ANT515, ANT516
Antenna adapters
E80390Adapter to increase the ranges for RFID antenna type M18
E80391Adapter to increase the ranges for RFID antenna type KQ
104
Identification systems
Extended functions for all ifm multicode readers
Recognition of codes and textIndependent of orientation and number of codes themulticode reader automatically decodes 1D and 2Dcodes.The new version also solves OCR tasks, e.g. for productidentification by means of type designations or seriesnumbers. All information such as expiry date or produc-tion date can now be directly read.
Suitable for industrial applicationsWith its protection rating IP 67, integrated lighting, different interfaces and large variety of operating distances and field of view sizes, the ifm multicode reader is suited for a large number of industrial applica-tions.
Identification of 1D/2D codes and text
Optical character recognition (OCR) alsowith position tracking
Variable character lengths
Easy handling
Compact industrially-compatible housing
Industrially-compatible multicodereader with text recognition
105
(04.2015)
1D/2D code readers
Type of sensor:CMOS image sensor, black/white, VGA resolution 640 x 480
Readable 2D codesECC200, PDF-417, QR, Micro QR, AztecReadable 1D codesInterleaved 2-of-5, Industrial 2-of-5, Code 39Code 128, Pharmacode, Code 93, CodabarEAN13, EAN13-Add-On 2, EAN13-Add-On 5EAN8, EAN8-Add-On 2, EAN8-Add-On 5UPC-A, UPC-A Add-On 2, UPC-A Add-On 5UPC-E, UPC-E Add-On 2, UPC-E Add-On 5GS1 DataBar Omnidirectional, GS1 DataBar TruncatedGS1 DataBar Stacked, GS1 DataBar Stacked OmniGS1 DataBar Limited, GS1 DataBar ExpandedGS1 DataBar Expanded Stacked
Wide range of applicationsThe ifm multicode reader is used in a wide range of industrial applications. It provides product tracking, production control or product identification in the mostvaried areas: automotive, electronic and food industries, conveyor technology or in machine tools and printingmachines. The standardised process interfaces RS-232, EthernetTCP/IP and EtherNet/IP ensure fast and easy integrationin industrial control technology.
Type Description Orderno.
Accessories
For further technical details please visit: www.ifm.com
Identification systems
Operating software for multicode reader E2I200
OPC server for multicode reader E2I210
High-grade stainless steel mounting setfor rod mounting, Ø 12 mm E2D110
High-grade stainless steel mounting setfor rod mounting, Ø 14 mm E2D112
Clamp,high-grade stainless steel, Ø 12 mm E21110
Clamp,high-grade stainless steel, Ø 14 mm E21109
Clamp linking ring,high-grade stainless steel E21076
Protective cover/diffuser E21165
Protective plastic cover E21166
Protective glass cover E21168
Laser protection pane E21169
Connection technology
Type Description Orderno.
Socket, M12,2 m PUR cable, 8 poles E11950
Socket, M12,5 m, PUR cable, 8 poles E11807
Ethernet, cross-over patch cable,2 m, PUR cable, M12 / RJ45 E11898
Ethernet, screened patch cable,2 m, PUR cable, M12 / RJ45 E12090
Ethernet, cross-over patch cable,10 m, PUR cable, M12 / RJ45 E12204
Ethernet, cross-over patch cable,20 m, PUR cable, M12 / RJ45 E12205
Common technical data
Operating voltage [V] 24 DC ± 10 %
Current rating [mA] 100 (per switching output)
Current consumption [mA] < 300
Ambient temperature [°C] -10...50
Protection rating, protection class IP 67, III
CoverMaterial Front lens
LED window
diecast zincglass
polycarbonate
Trigger
external, 24 V PNP internal,RS-232 / TCP/IP,
EtherNet/IP
Switching outputs (configurable) max. 2 (configurable),100 mA
Connection external illumination 24 V DC PNP
Parameter / process data interface
Ethernet 10Base-T /100Base-TX, RS-232,
EtherNet/IP
Dimensions [mm] 80 x 42 x 53.5
Motion speed [m/s] ≤ 7
Field of view size [mm] red light
50 75 100
Operating distance [mm] Orderno.
20 x 14
46 x 32
28 x 20
61 x 44
36 x 26
77 x 56
200
68 x 50
140 x 100
Field of view size [mm] infrared
20 x 14
46 x 32
28 x 20
61 x 44
36 x 26
77 x 56
68 x 50
140 x 100
Field of view size [mm] red light
200 400 1000
Operating distance [mm] Orderno.
40 x 30 80 x 60 200 x 150
2000
400 x 300
Field of view size [mm] infrared
40 x 30 80 x 60 200 x 150 400 x 300
O2I350
O2I352
O2I351
O2I353
O2I354
O2I355
106
Offers more than ISO monitoring
Compact vibration sensorFor the majority of rotating machines, such as motors,fans and pumps, which are often monitored manuallyor not at all, ifm electronic has a simple and interestingalternative. The latest member of the compact family type VN,VNB211, monitors online not only the overall vibrationcondition of machines and plants according to ISO 10816, but also acceleration levels (factory setting).In addition to vibration it is also possible to connect afuther process value such as temperature to monitorand measure machine health. The pushbuttons can beused to configure the parameters e.g. limit values. Tochange the basic configuration (factory setting) simplyuse the parameter software VES004.
2 vibration values e.g. velocity and acceleration or shock and bearing noise
Freely adjustable frequency bands e.g. formonitoring according to ISO 10816
Dual measurement point capability, additional process value e.g. temperature
On-board time-stamped history functionfor data collecting and trending
Intelligent vibration sensor –simply smart
Condition monitoring systems
107
(11.2015)
Vibration monitoring systems
DimensionsM
12x1
5162,4
14
65,3
36
20 M5
37,6
5
10
4
5,3
M8x
1
Accessories
Type Description Orderno.
USB / M8 cable E30136
Adapter UNF / M5(pack quantity 10 pieces) E30137
Power supply E30080
Wiring diagram
43
21
4
2 1
35
Pin 1: 5 V via USB interfacePin 2: USB_D-Pin 3: L-Pin 4: USB_D+
Pin 1: L+ (9.6...30 V DC)Pin 2: Out 1 switching output or
current output 0/4...20/22 mA (configurable)Pin 3: L-Pin 4: Out 2 switching outputPin 5: In 0/4...20 mA
For further technical data please go to: www.ifm.com
Condition monitoring systems
Vibration sensor VN• Process connection via M12 x 1 and
M8 x 1 connectors• Parameter setting via PC software VES004• Configuration via sensor pushbuttons
Connection technology
Type Description Orderno.
Socket, M12, 2 m black, PUR cable, screened EVC535
Socket, M12, 2 m black, PUR cable, screened EVC532
Technical data
Operating voltage [V]9.6...30 DC or using USB
(switching outputs not active)
Protection IP 67
Ambient temperature [°C] -30...60
Selftest •
Vibration sensorVNB211
Data interface USB; 2.0
History memoryRing memory,
686774 data records, with real-time clock
Outputs
2 switching outputs or1 switching output and
1 analogue output 4...20 mA (can be set using the sensor pushbuttons)
Input [mA] 1 analogue input 0/4...20
Display 4-digitalphanumeric display
Measuring range [g] 0...25
Measurementmethod Vibration acceleration / vibration velocity
Y connection cable,M12 plug / 2 x M12 socket E12405
Parameter software VES004
108
Extended functionality –6 configurable inputs
Diagnostic electronics with high performanceThe flexible configuration of the 4 dynamic inputs nowmakes it possible to connect and continually monitordifferent types of sensors. This is valid for VSE unitswith firmware version 11 or higher. The sensors can bevibration sensors type VSA, IEPE or process sensors witha 4...20 mA output. Two further analogue inputs canbe used to connect additional process sensors such asfor speed or temperature.This functionality provides different possibilities for machine and process monitoring. The on-board FIFO-memory with up to 600,000 values provides a simplemethod for data comparison and can be used for trending.
Simple networkingThe units can easily be connected to the company network using the Ethernet interface and the OPCserver software type VOS. Vibration and process datacan thus be integrated into higher systems such asSCADA or MES.
Either IEPE, vibration sensor type VSA, or 4...20 mA can be configured on all 4 dynamic channels
2 analogue inputs for sensors (4...20 mA/pulse)
Collection and monitoring of different ana-logue process data
Large on-board memory
Flexible data logger for vibrationand process values
Condition monitoring systems
109
(04.2015)
Technical data
Operating voltage [V] 24 DC ± 20 %IEPE input 24 DC + 20 %
Protection IP 20, III
Ambient temperature [°C] 0...70
Housing VSE002VSE100
DIN rail 1"DIN rail 2"
Diagnostic electronicsVSE002, VSE100
Dimensions
5011
4
LEDs
2
1
105
35,5
Wiring diagram
1817
2019
1413
1615
2221
2423
65
87
21
43
109
1211
Supply L- (GND)OU 1: switch/analog OU 2: switch
IN 1 (0/4...20 mA / pulse)GND 1IN 2 (0/4...20 mA / pulse)GND 2
1234
BNWHBUBK
4321
BKBUWHBN
I/O 7
3029
3231
3433
3635
2625
2827
4344
4142
4748
4546
3940
3738
GNDI/O 8GND
I/O 5GNDI/O 6GND
I/O 1GNDI/O 2GND
I/O 3GNDI/O 4GND
U-OUT (0...10 V)GND
U-IN 1 (0...10 V)GND 1U-IN 2 (0...10 V)GND 2
1234
BNWHBUBK
1234
BNWHBUBK
Supply L+ (24 V DC ±20 %)
Data interface Ethernet TCP/IP,(10 / 100 MBits)
History function integrated
1) Ethernet interface2) Combicon connector with screw connectors (optional)
Inputs / OutputsVSE002
4 dynamic inputs, sensor type VSA/IEPE/4...20mA
in any combination2 analogue inputs
(0/4...20 mA or pulse 24 V)1x digital alarm output
(PNP 100 mA)1x selectable digital
(PNP 100 mA) or analogue (0/4...20 mA / 0...10 V)
alarm output
Inputs / OutputsVSE100
4 dynamic inputs, sensor type VSA/IEPE/4...20mA
in any combination2 analogue inputs (0/4...20 mA
or 0...10 V or pulse 24 V)1x digital alarm output
(PNP 100 mA)1 x selectable digital
(PNP 100 mA) or analogue (0/4...20 mA / 0...10 V)
alarm output8 x digital outputs / inputs
(freely configurable) (PNP 100 mA)
Parameter software VES004
octavis OPC server softwareGerman / English VOS001
Connection cableEthernet cross-over patch cable2 m, PVC cable,RJ45 plug / RJ45 plug
EC2080
Connection cableEthernet cross-over patch cable5 m, PVC cable,RJ45 plug / RJ45 plug
E30112
Example VSE100
Vibration monitoring systemsCondition monitoring systems
For further technical data please go to: www.ifm.com
Accessories
Type Description Order no.
110
Software for diagnostic electronics type VSE and vibration sensors VN
Parameter settingThe new parameter software VES004 is used to set theparameters for diagnostic electronics type VSE. Withthe software it is possible to create a tree structure intowhich the units and sensors are integrated. The usercan then see his own familiar structure with regards toproduction sites, and machines and components.The software contains wizard functions to simplify creating parameter sets for vibration and process monitoring. It is therefore possible to set up and definesimple monitoring with practically no previous expertknowledge. Data administration such as parametersets, measurement data, recordings and history files is carried out according to the pre-defined project tree structure.
Visualisation of measurement data in different diagramme types
Comparison of measurement values fromdifferent sources in one diagramme
Visualisation of raw data resulting fromthe VSE dynamic channels
Integrated wizard function for the creationof parameter sets
Structured administration of units anddata as a tree structure
New parameter software withdata visualisation
Condition monitoring systems
111
(04.2015)
Visualisation (monitoring)Different types of diagrammes are available for visualising measurement values (column, tabular and x-y diagrammes). The configuration of axes, scaling anddata sources is very flexible. For example for the x-y diagrammes (such as history data or object measurement values) it is possible to define several y-axes. You arethen able to easily compare the measurement values ofdifferent sources (sensors) with different physical unitsor scaling in one diagramme. The diagnostic electronictype VSE can access all stages of the measurementchain from the time signal (raw data) to the frequencyspectrum right through to the object values and alarmdisplay in order to visualise the measurement values.The visualisation of the frequency spectrum containsseveral signal analysis tools. For example measurementlines or tools for order, harmonics and side-band analysis. The measurement values can be recorded and stored inthe software as well as recalled and exported.
Firmware updateWith the VES004 it is also possible to update the VSEfirmware. The software checks if the chosen firmware iscompatible with the unit connected and thus prevents the use of an incorrect version.
System requirementsWindows XP (basic functions), Windows 7, Windows 8.1Minimum resolution 1024 x 768 pixel256 MB RAM
The products
Type Description Order no.
Parameter software VES004
octavis OPC server softwareGerman / English VOS001
Connection cableEthernet cross-over patch cable2 m, PVC cable,RJ45 plug / RJ45 plug
EC2080
Diagnostic electronics for vibration sensors type VSA / VSP, cabinet mounting; frequency selectivemachine monitoring of up to 4 measurement points; Ethernet interfaceTCP/IP, on-board time-stamped historyfunction, 2 switching outputs or 1 switching and 1 analogue output, 8 further freely configurable I/O, counter function
VSE100
Object visualisation
Visualisation of the frequency spectrum
Visualisation of raw data monitoring
Vibration monitoring systemsCondition monitoring systems
For further technical data please go to: www.ifm.com
112
Modular mini controller withhigh-current relay outputs
ecomatmobile BasicIn many small and compact mobile applications, the requirements on control tasks are increasing. Cost-optimised, modular mini controllers for mobile useare in demand. ifm offers ecomatmobile Basic consisting of the com-ponents BasicRelay, BasicController and BasicDisplaythat are adapted to each other. This BasicController family is now complemented by the BasicController relay. Its special feature is made up of six protected powerrelay outputs with diagnostic capability for the supplyof high-current consumers in mobile machines. In addition it has multifunctional digital and analogueinputs that can be configured via the application soft-ware. The BasicController relay is freely programmablevia the IEC61131-3-compatible CODESYS software.
High-performance, protected relay outputs with diagnostic function
Connection of sensors and actuators without further external wiring
Powerful CAN interfaces for various communication tasks
Easy installation due to adapted mechanical ecomatmobile Basic concept
Programmable to IEC 61131-3 with CODESYS
Power management in mobile vehicles
Systems for mobile machines
113
(11.2015)
Mobile controllers
Functions and advantagesThe compact, flexible and inexpensive mini controllerreplaces the conventional relay logic and also demanding and complex process controllers.
• Mechanical designThe control electronics integrated in a compact plastic housing provides all the necessary connectionsfor the inputs and outputs, communication and pro-gramming. The coded connectors for mobile use areeasy to handle and available all over the world. Theconnection of sensors and actuators is carried out without further external wiring. Due to an increase ofthe protection rating through a cover and a pluggable cable seal the BasicController can also be used in areas that are exposed to splashing water.
• Powerful electronicsThe integrated 32-bit processor and the electronicsare optimally tailored to the application. Inputs andoutputs can be configured to the application via theuser program. The powerful plug-in relay outputs ensure the connection of high-current consumers. All relay outputs are with diagnostic capability and individually protected. Each output has a freely pro-grammable status LED. Thanks to the additionalmulti-functional inputs a flexible control module formobile machines is available.
• Programmable to IEC 61131-3The CODESYS software enables a clear and easy creation of the application software for the user. The control module BasicController supports all common CODESYS programming languages. Simpleand clearly structured function libraries are availablefor communication and special device functions.
• Communication interfacesThe BasicController is equipped with two CAN inter-faces to ISO 11898. These interfaces are used to exchange data with the connected BasicDisplay, further BasicController modules or the engine controller. Among others, the interfaces support theCANopen protocol and the J1939 protocol. The CANinterfaces are also used for programming. To do so, the unit electronics is directly and con-veniently activated via the powerful PC-CAN interfaceCANfox. In this way, operating system and application program can be loaded or parameters changed.
Applications:compact construction machines, attachments, mini vehicles, special functions
Inputs (total):Digital, analogue, frequencyDigital, resistance measurement
844
Outputs (total):Micro relay ISO 7588-3, 15 A (total current max. 60 A)Diagnostics via NO and NC contact ofthe relay. Protected via mini controller to DIN ISO 8820-3
6
Data memory SRAM [kB] 592
Data memory Flash [kB] 1536
Data memory (retain), FRAM [kB] 1
For further technical details please visit: www.ifm.com
Systems for mobile machines
Description Orderno.
BasicController relay 8 I / 6 O relay CR0431
Technical data
BasicController relay
The products
Housing Plastic, potted
Device connection AMP blade male terminals 6.3 mm
Protection rating,with cover EC0401, EC0402
IP 20IP 54
Operating voltage [V DC] 8...32
Current consumption [mA] ≤ 45
Temperature rangeOperation [°C]Storage [°C]
-40...75-40...85
Indicators LED Red / green
Processor PowerPC, 50 MHz
Supported CAN protocols
CANopen(DS 301 V 4.1)
SAE J 1939free CAN protocol
Standards and tests(extract)
CE,E1 (UN-ECE R10)
Starter set consisting of BasicController 12 I / 8 O, BasicRelay, BasicDisplay incl. software, power supply,cable and accessories
EC0400
Module cover IP 54 without display recess, with cable seal EC0401
Plug set for BasicController relay EC0464
Mounting and contact set for BasicController relay EC0465
Relay and fuse set for 12 V applications EC0466
Relay and fuse set for 24 V applications EC0467
CAN programming interface CANfox EC2112
Adapter set CAN/RS232 for CANfox EC2113
CODESYS programming software, German CP9006
CODESYS programming software, English CP9008
Programming software CODESYS V 2.3
114
ecolink –a new dimension in connection technology.
ecolink M12 for demanding applicationsMost applications require special solutions. Only high-quality materials, safe production processes and fault-less mounting lead to success in the long run.The integrated end stop protects the O-ring againstdestruction caused by tightening the nut too much.Mounting and removal are carried out without tools.The asymmetrically acting vibration protection holdsthe nut tight in its position, guaranteeing an optimumand permanent seal.High-quality materials especially adapted to the applica-tion and intensive monitoring during and after produc-tion guarantee maximum quality standards.
Connection technology meets the M12standard (EN 61076)
Optimum sealing even when mountedwithout tools
The mechanical end stop protects the O-ring against destruction
Permanent vibration protection with saw tooth contour
LEDs clearly visible even under brightlighting
Connection technology
From factory automation tomachine tool industry
ecolink M12 – The secure connectioneven in difficult applications
115
(11.2015)
Applications:Factory automation, machine tool industry, construction of machinery, hydraulics
For further technical data please go to: www.ifm.com
SocketsConnection technology
Technical data:Operating voltage:without LED: 250 V AC / 300 V DCwith LED: 10...36 V DCNominal current: 4 A (cURus 3 A)Protection: IP 67, IP 68, IP 69K
in locked condition with the matching counterpart.
Tightening torque nut: 0.6...1.5 NmAmbient temperature: -25...90 °CVibration / shock: 750 g, 1 million cyclesCable characteristics: drag chain > 5 million cycles
Materials:Housing / moulded body: TPUContact carrier: TPUCoupling nut: diecast zinc, nickel-platedContacts: gold-platedSealing ring: VitonCable: PUR, halogen-free, 4 x 0,34 mm2, Ø 4,9 mm
Approvals:cURus
Dimensions
15,5
M12x1 45
14
Example EVC001
15,5
M12x1 36,5
26,5
14
Example EVC004
15,5
M12x1 36,5
26,5
143 LED
Example EVC007
Type Description Order no.LED
M12 sockets
2.0 m
5.0 m
10.0 m
2.0 m
5.0 m
10.0 m
2.0 m
5.0 m
10.0 m
2.0 m EVC644
5.0 m EVC645
10.0 m EVC646
•
•
•
EVC001
EVC002
EVC003
–
–
–
EVC004
EVC005
EVC006
–
–
–
EVC007
EVC008
EVC009
•
•
•
3 x LED
3 x LED
15,5
M12x1 45
14
Example EVC644
116
For hygienic and wet areas inthe food industry
ecolink –The new dimension in connection technology.
ecolink M12 for standard applicationsMost applications require special solutions. Only reliableproduction processes and faultless assembly lead tosuccess in the long run.The integrated end stop protects the O-ring against destruction caused by over-tightening the nut. No toolsneeded for installation and removal.The asymmetrically acting vibration protection holdsthe coupling nut tight in its position ensuring a lowcontact resistance between the nut of the connectorand the housing of the connected device. This is extremely important for permanently high protection against strong noise interference.
Connection technology meets the M12standard (EN 61076)
The mechanical end stop protects the O-ring against destruction
Permanent vibration protection with sawtooth contour
Continuously high EMC interference protection
ecolink – The reliable connection evenwith strong noise field interference
Connection technology
117
(04.2015)
Sockets
For further technical details please visit: www.ifm.com
Connection technology
Technical data:Operating voltage:4-pole: 50 V AC / 60 V DC5-pole: 30 V AC / 36 V DCNominal current: 4 AProtection: IP 65, IP 67, IP 68, IP 69K / IIIIn locked condition with the matching counterpart.Tightening torque nut: 0.6...1.5 NmNote the maximum value of the counterpart.Ambient temperature:-25...100 °C, cable firmly laid5...100 °C, cable movedCable characteristics:drag chain, 1 million cycles
Materials:Housing / moulded body: PVCCoupling nut: high-grade stainless steel (316L / (1.4404)Contacts: gold-platedSealing ring: EPDMCable: PVC, shielded, 4 x 0.34 mm2, Ø 5.2 mm5 x 0.25 mm2, Ø 5.2 mm
Approvals:cULus in preparation
Dimensions
15,5
M12x1 45
14
Example EVT381
15,5
M12x1 36,5
26,5
14
Example EVT385
Type Connection /cable
Orderno.
Number ofpoles
Screen not connected
Shielding characteristics
Screen connected
x: Frequency in [MHz]y: Shielding characteristics in [dB]
2.0 m EVT3815.0 m EVT382
10.0 m EVT383
444
25.0 m
2.0 m5.0 m10.0 m25.0 m
2.0 m5.0 m10.0 m25.0 m
2.0 m5.0 m10.0 m25.0 m
EVT3844
EVT385EVT386EVT387
444
EVT3884
EVT389EVT390EVT391
555
EVT3925
EVT393EVT394EVT395
555
EVT3965
2.0 m EVT3975.0 m EVT398
10.0 m EVT399
444
25.0 m
2.0 m5.0 m10.0 m25.0 m
2.0 m5.0 m10.0 m25.0 m
2.0 m5.0 m10.0 m25.0 m
EVT4004
EVT401EVT402EVT403
444
EVT4044
EVT405EVT406EVT407
555
EVT4085
EVT409EVT410EVT411
555
EVT4125
118
ecolink –a new dimension in connection technology.
For hygienic and wet areas inthe food industry
ecolink M12 for demanding applications.Most applications require special solutions. Only high-quality materials, safe production processes and fault-less mounting lead to success in the long run.The integrated end stop protects the O-ring againstdestruction caused by tightening the nut too much.Mounting and removal are carried out without tools.High-quality materials especially adapted to the applica-tion and intensive monitoring during and after produc-tion guarantee maximum quality standards.
Connection technology meets the M12standard (EN 61076)
Optimum sealing even when mountedwithout tools
The mechanical end stop protectsthe O-ring against destruction
Visible and tactile marking of the ports
ecolink M12 – The secure connectioneven in difficult applications
Connection technology
119
(11.2015)
Technical dataOperating voltage:4-pole: 250 V AC / 300 V DC5-pole: 60 V AC / DCNominal current: 4 AProtection rating: IP 67, IP 68, IP 69Kin locked condition with the matching counterpart.Tightening torque: 0.6...1.5 NmAmbient temperature: -25...100 °C
Materials:Housing / moulded body: PACoupling nut (non-rotatable):high-grade stainless steel (316L / (1.4404)Contacts: gold-platedSealing ring: EPDM
Approvals:cRUus in preparation
Applications:For hygienic and wet areas in the food industry
Type Wiring diagram
No.
Order no.LED
T splitters
For further technical details please visit: www.ifm.com
Connection technology
Dimensions
1 x M12 male, 2 x M12 female
Wiring diagram
4
1 1
3
4
3
2
B
A
1
3
4
C
1 1
33
55
B
A2
4
2
1
3
5
4
2
4
C
1 1
3
5
3
5
44
B
A
1
3
5
4
2
C
1 1
2
3
2
3
4
B
A
1
2
3
4
5
5
4
5
C
1
2
3
4
1 1
3
5
3
5
22
B
A
1
3
5
2
4
C
5
1 1
3
5
4
3
4
B
A
1
3
4
5
C
5
6
1 EBT006–
2 EBT007
3 EBT008
4 EBT009
–
–
–
5 EBT010
6 EBT011
–
–
M12x1
48,716
389
21M12x1
CB
A
M12x1
14
120
ecolink –a new dimension in connection technology.
From factory automation tomachine tool industry
ecolink M8 and M12 for demanding applicationsMost applications require special solutions. Only high-quality materials, safe production processes and fault-less mounting lead to success in the long run.The integrated end stop protects the O-ring againstdestruction caused by tightening the nut too much.Mounting and removal are carried out without tools.High-quality materials especially adapted to the applica-tion and intensive monitoring during and after produc-tion guarantee maximum quality standards.
Connection technology meets the M12standard (EN 61076)
Optimum sealing even when mountedwithout tools
The mechanical end stop protectsthe O-ring against destruction
Visible and tactile marking of the ports
ecolink – The secure connectioneven in difficult applications
Connection technology
M8x1
48,716
389
21
M8x1
CB
A
4,3 M12x1
14
121
(11.2015)
Technical dataOperating voltage:4-pole: 250 V AC / 300 V DC5-pole: 60 V AC / DCEBC112: 50 V AC / 60 V DCNominal current: 4 A (EBC112, 3A)Protection rating: IP 67, IP 68, IP 69Kin locked condition with the matching counterpart.Tightening torque:0.6...1.5 Nm (EBC112: 0.3...0.5 Nm)Ambient temperature: -25...90 °C
Materials:Housing / moulded body: PACoupling nut (non-rotatable): CuZn/NiContacts: gold-platedSealing ring: Viton
Approvals:cRUus in preparation
Applications:Factory automation, machine tool industry, construction of machinery, hydraulics
Type Wiring diagram
No.
Order no.
NEW
Order no.
old
T splitters
For further technical details please visit: www.ifm.com
Connection technology
Dimensions
1 x M12 male, 2 x M12 female
1 EBC113E11562E12165
2 EBC114
3 EBC115
4 EBC116
E10803
E12265
–
5 EBC117
6 EBC118
–
–
Wiring diagram
M12x1
48,716
389
21
M12x1
CB
A
4,3 M12x1
14
4
1 1
3
4
3
2
B
A
1
3
4
C
1 1
33
55
B
A2
4
2
1
3
5
4
2
4
C
1 1
3
5
3
5
44
B
A
1
3
5
4
2
C
1 1
2
3
2
3
4
B
A
1
2
3
4
5
5
4
5
C
1
2
3
4
1 1
3
5
3
5
22
B
A
1
3
5
2
4
C
5
1 1
3
5
4
3
4
B
A
1
3
4
5
C
5
6
EBC112
1 x M12 male, 2 x M8 female
1 EBC112–
EBC113 – EBC118
122
Uniform parameter settingand visualisation for all IO-Link-enabled ifm sensors
Online parameter setting
Clear representation
Documentation and archiving
Transferable parameter sets
Automatic sensor identification
LINERECORDER SENSOR 4.0 –Parameter setting software for IO-Link sensors
Features• Online und offline parameter setting • Supports all IO-Link devices from ifm• Software and parameter description
in all supported languages• Detailed description texts of all parameter contents• Parameter sets grouped according to topics
Customer benefits• Optimised validation by means
of graphic visualisation of the process values• Paperless recording of parameter sets• Shortened set-up time• Optimised device replacement process
Automaticsensor
detection
ERP connect-
ivity
Trace-ability
Software
123
(04.2015)
For further technical details please visit:www.ifm-datalink.com
Parameter setting software
Enterprise Resource Planning,e.g. SAP, INFOR, BaaN
Manufacturing Execution System
– Diagnosis– Traceability
ERP
MESSCADA
Machine PLC
IO-Link sensors
From sensor to ERP
Further processing of the sensor values with thefreely scalable LINERECORDER modulesThe software framework LINERECORDER closes the information circuit from the sensor signal to the worldof ME systems and ERP solutions (e.g. SAP).
Software
Graphic representation of the process values• Graphic comparison of process values
with each other and with switching outputs• Simple, clear representation of the process values• Export of the process values to the table
Documentation and archiving • Save / load parameter sets • Archive parameter sets as PDF file
Device detection• Automatic identification of the ifm IO-Link sensors• Display of the characteristic sensor values• Save correct parameter transfer by recognising
non-compatible devices• Particularly easy adding of new and updated
IODD files
Features• Help texts and value limits support parameter
entry at the input stage.• Operational reliability by device detecton
and restoration of default values• Display of the IO-Link communication quality• Create and display equipment identification
(application-specific tag)• Add and update existing ifm IODDs with
a mouse click *)
*) if internet connection available
System requirements:– Windows XP SP3, Windows Vista SP2, Windows 7 SP1,
Windows 8, Windows Server 2008 SP2, Windows Server 2008 R2 SP1, Windows Server 2012
– CPU Intel Dual Core 2.0 GHz– 2 GB RAM– 5 GB free hard disk space– Web browser (Chrome, Firefox, Internet Explorer 9
upward)
LINERECORDER SENSOR (supplied on USB flash drive)Software for online and offline parameter setting of ifm IO-Link sensors via USB adapter
QA0001
Technical data
Description Order no.
124
*Some offered information is available country-specific.
www.ifm.comInformation around the clock andaround the globe in 23 languages on the internet.
• Information- product innovations- company news- exhibition info- locations- jobs
• Documentation- data sheets- operating instructions- manuals- approvals- CAD data
• Communication*- request for documents- recall service- live advice- newsletter
• Selection- interactive product selection aids- configuration tools- data sheet direct
• Animation- virtual product animations- flash movies (video sequences)
• Application- applications- product recommendations- calculation aids
• Transaction*- e-shop processing- e-procurement catalogues
125
Convenient order processingvia the e-shop** on the internet.
Secured authentication
Customer-related priceindication
Real time availability check
Personal product favourites
Online parcel tracking
Individual order history
Convenient quick input form
Simple order processing
Management of shippingaddresses
Confirmations by e-mail
**Already available in many countries.
Position sensors
Sensors formotion control
Industrial imaging
Safety technology
Process sensors
Condition monitoringsystems
Industrialcommunication
Identification systems
Systems formobile machines
Connectiontechnology
Overviewifm product range:
Accessories
ifm a
rtic
le n
o. 7
8001
710
· We
rese
rve
the
right
to
mak
e te
chni
cal a
ltera
tions
with
out
prio
r no
tice.
· Pr
inte
d in
Ger
man
y on
non
-chl
orin
e bl
each
ed p
aper
. 11/
15
Cert no. IMO-COC-027827
Visit our website:
www.ifm.com
ifm electronic gmbhFriedrichstraße 145128 EssenTel. +49 / 201 / 24 22-0Fax +49 / 201 / 24 22-1200E-mail [email protected]
Over 70 locations worldwide –at a glance at www.ifm.com