Innovación en
Analizadores: Un
establecido concepto
Agilent,
extendido ahora a todas
las necesidades de su
laboratorio
Juan Aybar
GC & GCMS
Marketing Program Manager
Agilent Technologies
Today’s Challenges Expecting More with Less
• Pressure to increase productivity
• Limited time for method development
Operating Expenses
• Resource limitations
• Reduced technical skills
Human Resources
• Meeting regulatory compliance
• Trace analysis in complex matrices Technology
2 Agilent Solutions
Solutions from the Past
La “solución” al problema tiene un significado
diferente en función del usuario y su entorno
TRATAR DE DAR RESPUESTA A TODO ELLO NO SIEMPRE ES SENCILLO
Solutions
Level 1 Level 2 Level 3 Level 4 Level 5
Instrument
installed
Checkout
Application
specific
column Application
specific
checkout
3rd party
support
Validated
method
Agilent
Support
√ √ √ √ √
√ √ √ √ √
√ √ √ √
√ √ √
√
√
√ Agilent GC and
GCMS Analyzers
Portfolio
The missing element
Application expertise
Partner Labs
The SOP of a Level 5 Solution
Agilent GC and GC/MS Solutions
Minimizes Method Development Requirements
Standard, pre-configured analyzers
Multi-residue, target list analyzers
HW only custom solutions
8 Agilent Solutions
Agilent GC, GC/MS Analyzer Concept Easy to Order, Specific to Required Application
9 Agilent Solutions
App. optimized
consumables Application
report
System with
application setup
w/o Analyzer
Analyzer trained
CE for I&F
Std. HW, SW
Configured for specific method with factory setup,
and chemically tested then field verified system
Custom
er CD
Analyzers Pre-configured to Compliance Methods Fast RGA: Configured per ASTM D1945, D1946, UOP 539
G3445B Agilent 7890 Series GC for Analyzer
• G3445B Option 1 x 112 (Capillary S/Sl inlet with EPC)
• G3445B Option 1 x 210 (FID w/EPC)
• G3445B Option 1 x 220 (TCD with EPC)
• G3445B Option 1 x 221 (TCD mounted on left side)
• G3445B Option 1 x 529 (Three Channel Fast RGA)
G3440A Option 2 x 309 (Pneumatics Control Module)
G3440A Option 702 (6-Port Valve - Column Isolation)
G3440A Option 708 ( 6-Port Valve - Sequence Reversal)
G3440A Option 754 (Four automated valves)
G3440A Option 2 x 801 (10-Port Valve - Gas Sampling)
G3440A Option 861 (Install GSV or LSV on left side of GC)
G3440A Option 701 Unheated (6-Port Valve - GSV)
G3440A Option 860 (Interface a GSV or LSV to S/Sl inlet)
G3440A Option 3 x 868 (Substitute Hastelloy-C valve - 6 port)
G3440A Option 2 x 869 (Substitute Hastelloy-C valve - 10 port)
G3440A Option 5 x 873 (Zero Volume Union to 0.32mm Column)
G3440A Option 874 (Install valve downstream)
19091P-S12 25 m x 0.32mm x 8um HP-PLOT/Al2O3 column
G1580-90200 Customer data CD
1460-1914 Capillary column hanger
19251-60540 Liner,split,straight,glasswool,non-deact
G3440-20008 Inlet filter in Hastelloy
G3440-20007 Spare Hastelloy Frits
G3440-20004 Sample Loop 100uL, Hastelloy,SL100CW-HC
G3440-20005 Sample Loop 0.5mL, Hastelloy,SL500CW-HC
G3440-20006 Sample Loop 25uL, in Nickel,SL25CW-Ni
G3591-82022 8Ft MolSieve 5A 60/80 in nickel
G3591-82020 3Ft HayeSep Q 80/100, Ni
123-1015 15m x 0.32mm x 5.00um DB-1 capillary column
G3182-60580 CPM Union, Inert
G1580-61160 NiCat HTR/Sensor
G3435-60503 FPD Electronic Cover
G3435-80500 Single FPD Detector Top Cover
5190-0519 RGA Checkout Sample with Oxygen
PC16218 1.7m HayeSep A 80/100 micro-packed column
PC16211 2Ft HayeSep A 80/100 micro-packed column
PC16219 1.5 m Mol Sieve 5A 80/100 micro-packed column
HCE1 Heated Column Enclosure
System pluming and setup according to application
Factory Application Checkout and Testing
Analyzer Manuel
CE specialist onsite I&F
Analytical Confidence: analyzer option
includes required hardware (valves with
control and method specific consumables),
analytical method, and custom report
10 Agilent Solutions
Column1, 2, 3
are wound
around the
column mandrel
Isothermal Column
Enclosure
Fast RGA -- G3445B #529 Factory Configured and Chemically Tested
optional
11 Agilent Solutions
Fast RGA – G3445B #529 Chromatograms
Hydrocarbon Channel
Permanent and Light Gases Channel
Hydrogen Channel
7.5 min analysis
12 Agilent Solutions
Pre-configured standard method analyzers Per Compliance Methods, e.g., ASTM, EN, UOP, GPA
Searchable, 139 pages, Agilent HPI Solution Guide PN: 5991-1561EN
13 Agilent Solutions
Agilent GC and GC/MS Solutions
Minimizes Method Development Requirements
Standard, pre-configured analyzers
Multi-residue, target list analyzers
Exclusive analyzer configurations
HW only custom solutions
14 Agilent Solutions
• Facilitates system-to-system method transfer and column replacement
Retention Time Locking
• Large-volume injection enhances trace-level detection Multimode Inlet (MMI)
• Improves uptime and shortens analysis times
Capillary Flow Technology (CFT) and
Backflush
• Comprehensive and optimized MRM database for 1000+ compounds
Comprehensive MS/MS MRM Database
• Factory setup and check out with pesticide mixture Pre-config. and factory
setup / tested
New
Multi-Residue and Target List Analyzer Pesticide & Environmental Pollutants 2.0 Analyzer
15 Agilent Solutions
Benefit of Backflushing It ensures the highest data quality with GC/MS/MS!
16
Increased Productivity:
• Selectivity of MS/MS eliminates “dirty matrix” - not seen but exists
• Demanding LOD necessitates users inject larger sample volumes
• Many late eluting peaks are not “chromatographically ideal” and leave a
residue throughout the column
• Heavy matrices contaminate the source faster – performance is LOST!
Slight decrease in sensitivity as a trade-off due to the additional flow
introduced from the Aux EPC.
Agilent Solutions
1075 Pesticides & Environmental Pollutants
Average of 8 MRM transitions for each compound
-- provides alternatives to minimize matrix interferences
-- includes relative intensities for all transitions
Retention times (RT) and indexes (RI) for three GC methods
-- Fast method (20’) Full screening method (40’ CF) and Flexible method: (40’ CP)
Comprehensive and Flexible MRM Database Pesticide & Environmental Pollutants 2.0 Analyzer
Compound Classification Total Number
Pesticides (fungicides, herbicides, insecticides, rodenticides and others) 675
Breakdown Products 42
Deuterated Compounds 6
Polybrominated Diphenyl Ether (PBDE) 4
Polybrominated Biphenyl (PBB) 1
Polychlorinated Biphenyl (PCB) 209
Polycyclic Aromatic Hydrocarbon (PAH) 26
Phthalates 17
Additional Semi-volatile Pollutants 94
17 Agilent Solutions
Multi-residual, target list analyzer example 1000+ Pesticide and Environmental Pollutants
Ordering Structure
G3445B Agilent 7890 Series:
• G3445B Option # 002 or 003 (Fast oven)
• G3445B Option # 150 or 151 (MMI)
• G3445B Option # 411 GC/MS/MS multiresidue
Analyzer w. CP method)
Agilent 7693 Series:
• G4513A 7693A Autoinjector Module
• G4514A 7693A Autosampler tray module
Agilent 7000 Series:
• G7010AA 7000B Triple Quad GC/MS/MS EI bundle
• G7010AA Option # SP1 System indicator ($0)
Note:
For GC/MS/MS P&EP analyzer option: includes 1000+
compd MRM DBL
But in GC/MSD analyzer option: it doesn’t include DRS
SW or DRS DBL, need to be ordered separately
G3440A Option # 301 (Three channels of auxiliary EPC)
G3440A Option # 305 (Factory plumbing For quick installation)
1x19091S-433UIHP-5MS Ultra Inert 30m, 0.25mm, 0.25um
1xG3186-60580 Purged Ultimate Union Assy, Inert
2xG3182-00100 CPM Union, Oven Wall Clip
4xG2855-20530 Internal nut for micro fluidic product
1xG2855-90025 CD - CFT Accessories Info & Calculators
1x0100-0680 Tee-Union, 1/16inch Brass
1xG3430-60550 Tubing Block Assembly
1x0100-1329 Ferrule, 1/16" Vespel 10/PK
1x5080-8853 Ferrule Graphite 320um 0.5mm id 10/PK
1x5188-5365 Liner O-Ring, Non-Stick 10PK
1x5183-4759 Agilent Advanced Green 11mm septa, 50/pk
1x5188-5361 Siltite Ferrules,0.25mm column,10 pack
1xG2855-20555 MSD,Ultimate Union and QuickSwap swaging nu
1xG1099-20030 Column Installation tool for 5973/5975
1xG2855-60200 Ferrule Pre-Swage Tool,Capillary Flow
1x5190-0494 Pesticide Checkout std 100ug/L 3x1ml
1xG3186-00201 Standoff Bracket for CFT Unions
1xG1580-90200 Customer data CD
2xG2855-60570 Plug for microfluidic manifold or unions
1xG2855-40001 Magnifier, 3x, 6x, paddle, plastic
1xG3430-20011 Aux Frit Case - Zero Restriction
1x160-7625-5 Silconert treated Inert Fused Silica 5m, 0.15mm
1x0100-2354 1/16"od x .010" id x 1m Tube, 316 SST
1x5190-2293 Liner,UI,splitless,sngle taper,glasswool
1xG9250-64000 Pesticide & Envirn Pollutant MRM DB
System pluming and setup according to application
Analyzer Manuel CE specialist onsite I&F
Confirm with Confidence:
analyzer option includes required
hardware, method specific
consumables and analytical
methods (3).
Plus 1000+ compound MRM DB
18 Agilent Solutions
Benefit of having 8 transitions in the database Example: Analyze Atrazine in Different Matrices
Top 2
transitions
• Background interferences can vary significantly from matrix to matrix
• Top 2 MRM transitions (most responsive) may not be the most selective transitions
• Quantitation results can be inaccurate due to poor choice of transitions
19
Pepper Orange Pear Flour Spinach Strawberry
target analyte interference
from matrices
Agilent Solutions
No Need of extensive MRM transition development
Optimized MRM Transitions for Atrazine in DB
20 Agilent Solutions
Evaluate Atrazine Top 4 MRMs in Different Matrices
21 Agilent Solutions
Benefit of having 8 transitions in the database Example: Analyze Atrazine in Different Matrices
Optimized
transitions
• Alternative transitions eliminates the interference
• Minimum interference for improved analytical performance
22
Pepper Orange Pear Flour Spinach Strawberry
target analyte
Agilent Solutions
Other Multi-residue, Target List Analyzers Factory Configured and Chemically Tested
Facilitates utilization of Agilent’s state-of-art technologies
G3445B Opt. Analyzer Description
411 GC/MS/MS Pesticide Analyzer (CP-PC-BF)
412 GC/MS/MS Pesticide Analyzer (CF-MC-BF)
421 GC/MS/MS PAH Analyzer
451 GC/MSD Pesticide DRS Screening Analyzer
455 GC/MSD/FPD/ECD Pesticide Analyzer
461 GC/MSD Semi-Volatiles Analyzer
465 3 in 1 Environmental GC/MSD Analyzer
471 GC/MSD Toxicology DRS Analyzer w. NPD
475 GC/MSD(Diff) Toxicology Analyzer (CF)
481 HSS GCMSDFID Residual Solvents Analyzer
482 FAME in JetFuel Analyzer
23 Agilent Solutions
Agilent GC and GC/MS Solutions
Minimizes Method Development Requirements
Standard, pre-configured analyzers
Multi-residue, target list analyzers
HW only custom solutions
24 Agilent Solutions
Market Situation
Unreliable supply of helium worldwide and increasing prices have
customers seeking alternative carrier gas solutions
25 Agilent Solutions
Agilent’s COMPREHENSIVE Solutions Carrier Gas Decision Tree
Consider migration to H2 Consider migration to N2 He Conservation
GC/MS specific H2
considerations
Are you willing to convert
to alternative gasses?
Is the Application based on
GC or GC/MS?
Does the current GC method
have more than enough resolution?
No
No
Yes
Yes
GC/MS GC
26 Agilent Solutions
Introduce Programmable He Conservation Module Helping Your Facility Address Issues Related to Helium
Combines with 7890B Sleep-Wake feature
Automatically switches carrier gas supply to N2 during GC idle time
TWO Critical Components
• Carrier gas switching EPC module
• 7890B Sleep/Wake Feature
Plus …
• Chromatographic grade N2 gas
27 Agilent Solutions
Carrier Gas Switch EPC Module Ensures Business Continuity
To Inlet EPCs Purge
He in
N2 in
Flow channel inside
the bridge block
Std. Aux EPC
28
• Built on 5th generation EPC
• Fully integrated and
controlled by Agilent CDS
• Purge channel prevents
cross contamination of gases
• Precise pressure control
between tank and GC
• In AWAKE mode, switches
between gases within 15-
30min for most detectors
Agilent Solutions
How it Works ? Helium Saving Mode (Nitrogen Carrier, or Sleep Mode)
29
Bridge Block
To GC Inlet
EPC
AUX EPC 1
Nitrogen
70 psig
AUX EPC 3
Purge Vent
10 psig
AUX EPC 2
Helium
0 psig
24.2 mL/min N2
(< 0.2 mL/min)
He 25.2 mL/min N2
1.0 mL/min (out)
Helium OFF, Nitrogen ON at 70 psig
Agilent Solutions
GC/FID Wake Method: 15-30 Min
GC/MS Wake Method: 15-30 Min
Some other detectors may need longer
30
How it Works ? Normal Operation Mode (Helium Carrier or Wake Mode)
To GC Inlet
EPC
AUX EPC 1
Nitrogen
0 psig
AUX EPC 3
Purge
1.0 psig
AUX EPC 2
Helium
80 psig
24.2 mL/min He
(< 0.2 mL/min) N2 25.2 mL/min He
1 mL/min (out)
Bridge Block
Helium ON at 80 psig, Nitrogen OFF
Agilent Solutions
How It Works: Configuring Sleep/Wake Operation Simple, Straight Forward Setup
31 Agilent Solutions
Performance: No Change in Chromatography After
N2 Carrier Sleep Method. GC/FID Analysis
32
Day 1 - Original He carrier gas run
Day 2 – First He carrier gas run after overnight N2 Sleep.M method
Day 3 – First He carrier gas run after overnight N2 Sleep.M method
14 16 18 20 22 24 Min.
Agilent Solutions
Performance: Pass MS Tune Within 15min After
Switching From N2 To He As Carrier. GC/MSD
5000
50000
500000
5000000
0 5 10 15 20
Co
un
ts
Time (min)
Nitrogen Background
5 mL/min He
2 mL/min He
Counts of Nitrogen Ion
Time (min) 5 mL/min He
Relative to
Saturation 2 mL/min He
Relative to
Saturation
3 1735168 20.69% 8388096 100.00%
4 1033280 12.32% 4959232 59.12%
5 590080 7.03% 1618944 19.30%
6 354112 4.22% 722944 8.62%
7 228480 2.72% 333696 3.98%
10 56984 0.68% 102576 1.22%
15 9052 0.11% 17080 0.20%
33 Agilent Solutions
Carrier Gas Savings Calculator Save Helium by > 90% compared to a typical use
Helium supplies last MUCH longer
Gas saver mode: 9 times longer
N2 standby: another 3.3 times more
Total save: last 30 times longer
For instruments routinely in stand-
by, savings are even greater
“Sleep more, Save more”
Carrier Gas Savings Calculator
Change values in gray boxes to calculate savings for your operating parameters
Method:
Column:
Gas Flow Conditions
He Carrier Flow (mL/min): 1.2
He Split flow (mL/min): 190
Gas Saver Flow (mL/min): 20
Gas Saver On (min): 3
Run Time(min.): 30
Gas Volume in Cylinder (L): 8000
Runs per Day: 15
He Cylinder Cost ($): 300
N2 Cylinder Cost ($): 60
Parameter No Gas Saver Gas Saver OnGas Saver +
N2 Standby
Daily He Usage (L) 275 30 9
He Cylinder Life (days) 29 265 873
Daily N2 Usage (L) 0 0 21
N2 Cylinder Life (days) 0 0 381
Yearly He Cost ($) 3,769 413 125
Yearly N2 Cost ($) 0 0 57
Yearly Total Gas Cost ($) 3,769 413 183
ASTM D7504 - Analysis of Trace Impurities in Monocyclic
HP-INNOWax, 30 m x 0.32mm ID x 0.25 um
34 Agilent Solutions
Customer Benefits Ensuring Business Continuity
• Seamless integration
Fully integrated with 7890B and CDS (OpenLAB, Mustang, Mass Hunter)
Method includes carrier gas ID and set points for compliance and transfer
Easily implemented using new OpenLAB Sleep/Awake functions
• Greater reliability
Based on proven 5th generation AUX EPC
Warning from 7890 if set points are not reached
For hydrogen users, nitrogen substitution when GC idle
• Greater performance
Purge channel prevents cross contamination of gases
Acts as an intermediate pressure regulator from the tank to inlet EPC to ensure greater analytical precision
35
Thermo
PE
No more worries about He shortage,
No change to method, eliminates revalidation of analytical method !
Agilent Solutions
Agilent GC and GC/MS Solutions
Minimizes Method Development Requirements
Standard, pre-configured analyzers
Multi-residue, target list analyzers
HW only custom solutions
36 Agilent Solutions
37 Agilent Solutions
Juan Aybar
GC & GCMS Marketing Program Manager
Agilent Technologies