Infinity Quaternary LC can enhance your lab efficiency · Page 1 The new Agilent 1290 Infinity...
Transcript of Infinity Quaternary LC can enhance your lab efficiency · Page 1 The new Agilent 1290 Infinity...
Page 1
The new Agilent 1290 Infinity Quaternary LC
How binary pump-like performance can enhance your lab efficiency
Sebastian KraheProduktspezialist HPLCAgilent Technologies
Page 2
The 1290 Infinity Quaternary LC SystemLeveraging the Performance of the 1290 Infinity Binary LC System
1290 Infinity DAD with 60mm cell (& HDR optional)
1290 Infinity TCC with broadest valve selectivity
1290 Infinity Autosampler (with Flexible Cube for lowest carry-over)
1290 Infinity Quaternary Pump
Page 3
Innovation: 1290 Infinity Quaternary PumpQuaternary Pump with Binary Pump-like Performance
1290 Infinity Quaternary Pump
• Boost PerformanceHighest accuracy and precision for composition and flow, with exceptionally low delay volume
• Save TimeAccelerates transfer of existing HPLC methods to UHPLC
• Reduce CostsOutstanding UHPLC performance at HPLC-like costs of ownership
Page 4
1290 Infinity Quaternary PumpVarious tools enabling the high performance
4-channel Degasser
MCGV (Multi-Channel-Gradient-Valve) Pump Head
Multi-Purpose-Valve
Switchable Jet Weaver Mixer
In-line Filter
Inlet-Weaver
Page 5
Multipurpose valve functions for highest comfortStandard Application for standard Delay Volume
Page 6
Power RangeFor any kind of analysis
Composition Accuracy and Precision< 0.15 % RSD or 0.02 min SD± 0.4 % (1-99 % Composition B)
High RT precision in gradient runs
Flow Accuracy and Precision< 0.07 % RSD or 0.01 min SD± 1.0 % or 10 µL
High RT precision in isocratic runs
Agilent 1290 Infinity Quaternary PumpSpecifications & Benefits
Composition Range1-99 %
Wide analytical range
Delay Volume< 350 µL
For fast quaternary gradients
Page 7
Different mixtures (H2O, MeOH, ACN) at different pressures and different flow rates
Full application range!
Composition Accuracy and PrecisionStep Gradient Analysis with Tracer
Page 8
Flow and Composition Accuracy and PrecisionIsocratic analysis of Glucocorticoids
3: Hydrocortisoneacetate
1: Hydrocortisone 2: Beclomethasone-di-proprionate
Column: Agilent ZORBAX Eclipse Plus C18, 4.6 x 100 mm, 5 µm (p/n 959996-902)
Mobile phase: Water/ Acetonitrile = 30/70Flow rate: 1 mL/minStop time: 5 minInjection vol.: 3 µL (needle wash for 3 sec)Column Temp.: 30 °CDAD: 254/10 nm, (ref 400/ 80 nm), 20 Hz, slit 4 nm
Page 9
Flow and Composition Accuracy and PrecisionIsocratic analysis of Glucocorticoids
min1 1.5 2 2.5 3 3.5
mAU
0
5
10
15
20
25
30
Water/ACN 29:71
1
2
3
Water/ACN 31:69Water/ACN 30:70
RT of compounds very sensitive regarding changes in
mobile phase composition!
Page 10
Accuracy and PrecisionIsocratic analysis of Glucocorticoids
min0 1 2 3 4
mAU
0
5
10
15
20
25
30
35
3: Hydrocortisoneacetate
1: Hydrocortisone
2: Beclomethasone-di-proprionate
Specification (< 0.07 %)
Page 11
Accuracy and PrecisionDynamically vs. pre-mixed solvents
A/B = 70:30
Isocratic composition by dynamic mixing:
Isocratic composition by premixed solvent:
A/B = 70:30
Which method is better?RSD RT(%)
Page 12
Accuracy and PrecisionDynamically vs. pre-mixed solvents
For illustration only, data can be found in Agilent Application Note 5991-0098EN
Single operator,single bottle
Dynamic mixing
Retention time precision
Page 13
Accuracy and PrecisionDynamically vs. pre-mixed solvents
For illustration only, data can be found in Agilent Application Note 5991-0098EN
Single operator,single bottle
Single operator,multiple bottles
Dynamic mixing
Retention time precision
Page 14
Accuracy and PrecisionDynamically vs. pre-mixed solvents
For illustration only, data can be found in Agilent Application Note 5991-0098EN
Single operator,single bottle
Single operator,multiple bottles
Multiple operators,multiple bottles
Dynamic mixing
Retention time precision
Page 15
Accuracy and PrecisionGradient Analysis of Clopidole
Clopidole
Column: Agilent ZORBAX SB-C18, 4.6 x 250 mm, 3.5 µm (p/n 884950-567)Mobile phase: A = Water/ACN (95/5) + 0.1 % TFA
B = Water/Acetonitrile(40/60) + 0.1 % TFA
Gradient: 0 – 100 % B in 15minFlow rate: 1 mL/minStop time: 15 minInjection vol.: 1 µLColumn Temp.: 30 °CDAD: 263/10 nm, (ref. 400/ 80 nm), 10 Hz
Clopidole is used as prophylactics and/or therapeutics in the prevention or treatment of coccidiosis in the poultry and rabbit industries. It is added to finished feed in a concentration range of 100 to 125mg/kg.
Page 16
Accuracy and PrecisionDynamically vs. pre-mixed solvents
Which method is better?RSD RT(%)
5 60 % B
Gradient from 5 to 60 % B by dynamic mixing:
H2O+0.1% TFA
ACN+0.1% TFA
Gradient from 0 to 100 % with premixed solvent:
0 100 % BH2O
+0.1% TFA
ACN+0.1% TFA
Page 17
Accuracy and PrecisionDynamically vs. pre-mixed solvents
min6.0 6.4 6.8 7.2 7.6
mAU
0
50
100
150
200
min6.0 6.4 6.8 7.2 7.6
mAU
0
50
100
150
Dynamic mixing 5 60 % B Premixed, 0 100 % B
Page 18
Accuracy and PrecisionDynamically vs. pre-mixed solvents
0
0.1
0.2
0.3
0.4
0.5
Dynamic mixing Premixed
RSD
RT
(%)
5 60 % B
Specification (< 0.15 %) 0 100 % B
Retention time precision
Page 19
Power RangeFor any kind of analysis
Composition Accuracy and Precision< 0.15 % RSD or 0.02 min SD± 0.4 % (1-99 % Composition B)
High RT precision in gradient runs
Flow Accuracy and Precision< 0.07 % RSD or 0.01 min SD± 1.0 % or 10 µL
High RT precision in isocratic runs
Agilent 1290 Infinity Quaternary PumpSpecifications & Benefits
Composition Range1-99 %
Wide analytical range
Delay Volume< 350 µL
For fast quaternary gradients
Page 20
Ternary/Quaternary GradientsBlend Assist
You need different concentrations of modifiers in your analysis, would like to have just one stock-solution and do online dilution to profite from the quaternary mixing capability of your pump? Here is a simple tool – BlendAssist!
Water Water 1% TFA
ACNACN
1% TFA
Desired method conditions - example: 1. 5 to 95% gradient of ACN with 0.1% TFA in
Water and 0.08% TFA in ACN2. 20 – 80% gradient of ACN with 0.5% TFA in
Water and 0.4% TFA in ACN
Without BlendAssist you need to either pre-mix the required solvents or by using stock-solutions of TFA in Water and ACN to program complex gradients (%A, B, C, D).
With BlendAssist: just program your binary organic/aqueous gradient and define the dilution factor!
Page 21
Ternary/Quaternary GradientsBlend Assist, different Phosphate buffer concentrations
Column: Agilent ZORBAX Eclipse Plus C18, 4.6 x 100 mm, 1.8 μmMobile phase: A = Water
B = Water/Acetonirile 20:80 + 0.05 M NaH2PO4, pH=4.6Gradient: var.Flow rate: 1.5 mL/minStop time: 8.5 minInjection vol.: 1 µLColumn Temp.: 40 °CDAD: 270/10 nm, (ref. 360/ 100 nm), 20 Hz
Quinidine
N
OH
N
OCH3 CH2
N
NH2
ON
CH3
CH3
CH3
CH3
Disopyramide
Page 22
Ternary/Quaternary GradientsBlend Assist, different Phosphate buffer concentrations
min0 1 2 3 4 5 6 7 8
mAU
0
100
200
300
400
0.05 M buffer
0.025 M buffer
0.01 M buffer
Procainamide Acetyl-Procainamide
Disopyramide
Quinidine
Page 23
Ternary/Quaternary GradientsBlend Assist - simple Tool for Online-Dilution of Modifiers and Gradient Set-Up
BlendAssist - Solvent/modifier channel definition
Page 24
1290 Infinity Quaternary PumpConclusion
Full 1290 Infinity LC Power range
Highest composition precision and accuracy, solvent independent and across pressure and flow rate range
Full application range with binary-like pump performance!
Blend Assist for Buffer/Additive Blending
ISET-ready!
Full flexibility!