Presentation on Site Master/Analyzer
Presented by :- W. Bhushan. B
![Page 2: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/2.jpg)
2
Introduction to Site Analyzer
![Page 3: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/3.jpg)
TOP VIEW OF SITE ANALYZER
RS-232 Printer port
RF Antenna port
Charging port
![Page 4: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/4.jpg)
4
Selection Buttons
Operation Buttons 1 2 3
4 5 67 8 9
0 . +/-
ESC
Enter
Arrow Keys
Power Button
Night Vision Button
LED PWR ONLED Charging
DISPLAY
![Page 5: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/5.jpg)
5
Requirement For VSWR & Return Loss Measurement
• Site Analyzer • Adapter(1/2”M to 7/8”F)• Dummy Load• Calibration Kit• Adapter• Site Analyzer Software• D-9 Serial Straight Cable
![Page 6: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/6.jpg)
6
PROCEDURE
• Put ON the Site Analyzer by Press & hold ON/OFF Button.
• A screen appear on the display showing Serial No. & operating frequency range Etc.
• Screen resume to any mode in which it was switched OFF.
• Suppose the mode is Fault location.
![Page 7: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/7.jpg)
Press & Hold ON/OFF Button
WELCOME SCREEN
Bird 2500 Ex780-2500 MHz
![Page 8: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/8.jpg)
8
Fault location
Distance(m)450
-------
1
1.5Save/Recall
Auto Scale
Hold
------ 0
Calibration full
VSW
R
![Page 9: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/9.jpg)
9
Rite now our Aim is measure VSWR So for measuring VSWR Mode should be Measure Match
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Fault location Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
Press Mode Button
VSW
R
![Page 10: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/10.jpg)
10
Select Mode
Distance(m)450
-------
1
1.4Measure Match
Fault location
Measure Power
------ 0
Calibration full
VSW
R
![Page 11: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/11.jpg)
11
Measure Match
Frequency(MHz)2500
-------
1
1.5Save/Recall
Auto Scale
Hold
------ 780
Calibration full
VSW
R
![Page 12: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/12.jpg)
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Fault location
Sele
ction
Butt
on
Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
Press Config. button
VSW
R
12
![Page 13: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/13.jpg)
13
Frequency(MHz)1880
-------
1
1.4Frequency
Limit
Hold
------ 1710
Press frequency button
Calibration full
VSW
R
Measure Match
![Page 14: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/14.jpg)
14
Measure Match
Frequency(MHz)2500
-------
1
1.4Save/Recall
Auto Scale
Hold
------ 780
Start Freq 780Stop Freq 2500
Set the frequency by using Arrow Key or Numeric key pad
Calibration full
VSW
R1 2 3
ESC4 5 6
7 8 9ENTER
0 . +/-
![Page 15: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/15.jpg)
15
2500
-------
1
1.4Save/Recall
Auto Scale
Hold
------ 780
Set the frequency
Start freq Stop freq
890
960
Frequency(MHz)
MHz
MHzCalibration full
VSW
R
ENTER
ESC
Measure Match
![Page 16: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/16.jpg)
16
Frequency(MHz)960
-------
1
1.4Save/Recall
Auto Scale
Hold
------ 890
Start Freq 890 MHzStop Freq 960 MHz
Calibration OFF
VSW
R
Measure Match
![Page 17: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/17.jpg)
17
To ON the calibration Press Calibration button
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Measure Match Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
VSW
R
![Page 18: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/18.jpg)
18
Frequency(MHz)960
-------
1
1.4Short
Open
Load
------ 890
Start Freq 890 MHzStop Freq 960 MHz
Calibration OFF
Connect calibration kit to Site Analyzer port
VSW
R
Measure Match
![Page 19: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/19.jpg)
19
Calibration Kit
Load
LoadOpen
½”M
½”M
½”M
short
Open
![Page 20: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/20.jpg)
Open / short /Load
![Page 21: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/21.jpg)
21
Frequency(MHz)960
-------
1
1.4Short
Open
Load
------ 890
Start Freq 890 MHzStop Freq 960 MHz
Calibration OFF
Short changes to done
Now apply open to the port and press
OpenThe OPEN changes to done
At last apply Load to Site master port and
press load button
LOAD changes to done
VSW
R
Measure Matchapply Short to the
port and press Open
![Page 22: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/22.jpg)
22
Frequency(MHz)960
-------
1
1.4Save/Recall
Auto Scale
Hold
------ 890
Start Freq 890 MHzStop Freq 960 MHz
Calibration full
VSW
R
Measure Match
Press Auto scale
![Page 23: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/23.jpg)
23
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Measure Match Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
Press Marker
ACTIVATE Marker
VSW
R
![Page 24: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/24.jpg)
24
Frequency(MHz)960
-------
1
1.4M1
OFF
-------
------ 890
Start Freq 890 MHzStop Freq 960 MHz
Calibration full
To Activate M1 the button OFF to
ACIVEVS
WR
Measure Match
ACTIVE
Like Wise We can Do this Up to Marker M6
ESC
![Page 25: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/25.jpg)
25
Measure Match
Frequency(MHz)960
-------
1
1.4Save/Recall
Auto Scale
Hold
------ 890
Calibration full
M1
M1 925 1.18
VSW
R
![Page 26: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/26.jpg)
26
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Measure Match Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
To Change the marker Position to top most point press UP key of
Arrow button
![Page 27: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/27.jpg)
27
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Measure Match Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
To Change the marker to lowest point press
the down arrow
VSW
R
![Page 28: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/28.jpg)
28
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Measure Match Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
Press the right and left key to move the marker left and right along the
trace.
VSW
R
![Page 29: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/29.jpg)
29
Measure Match
960
-------
1
1.4Save/Recall
Auto Scale
Hold
------ 890
Calibration fullM1 910 1.45
VSW
R
Arrow Buttons
Press the right and left key to move the marker left and right along the
trace.
![Page 30: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/30.jpg)
30
To find the fault location change the mode to Fault location
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-
Measure Match Power
Night Vision
LED
Arrow Buttons
Numeric Keypad
Press Mode button
VSW
R
![Page 31: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/31.jpg)
31
Distance(m)
-------
1
1.5Measure Match
Fault location
Measure Power
------
Calibration full
Press the Fault location button
VSW
R
SELECT MODE
![Page 32: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/32.jpg)
32
Distance(m)450
-------
1
1.4Distance
Limit
------ 0
Calibration full
M1
Press the distance button
VSW
R
Fault Location
![Page 33: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/33.jpg)
33
Distance(m)450
-------
1
1.4Distance
Limit
------ 0
Calibration full
M1
Start distance
Stop distance
Max distance
0
450
450
Change the Start/ stop distance by pressing the numeric key pad
VSW
R
Fault Location
1 2 3ESC
4 5 6
7 8 9ENTER
0 . +/-Numeric Keypad
ESC
![Page 34: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/34.jpg)
34
Fault Location
Distance(m)50
-------
1
1.4Save/ Recall
Auto Save
Hold
------ 0
Calibration full
M1
M1 4.0 1.26
VSW
R
![Page 35: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/35.jpg)
35
Fault Location
Distance(m)25
-------
1
1.4Save/ Recall
Auto Save
Hold
------ 0
Calibration full
M1
M1 10 1.37
To save the reading press save/recall button
The screen show as
VSW
R
![Page 36: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/36.jpg)
36
T
P
Q
R
S
A F K P U Z * _
B G L Q V Space : =
C H M R W [ - ,
D I N S X ] / “
E J O T Y . + #
Press the button to write the name
The letter appear here
PQS
![Page 37: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/37.jpg)
37
Fault Location
-------
Save
Recall
Edit
Delete
TV-1D 21/3/2013 10:45AM
Bhushan-1M 22/3/2013 04:07AM
To recall the traces press recall button
To edit the traces press Edit button
To delete the traces press Delete button
![Page 38: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/38.jpg)
38
-------
Watt
-------
-------
------
Measure Power
![Page 39: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/39.jpg)
![Page 40: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/40.jpg)
40
Measure Power
-------
------
dBm
-------
------
FWD : 40 wREF : 0.2 w
50 W
0
![Page 41: industrial training in telecom in delhi](https://reader034.fdocuments.us/reader034/viewer/2022051610/549e6253ac7959504c8b4583/html5/thumbnails/41.jpg)