Industrial Estatecalabarzon.emb.gov.ph/.../03/Ecoindex-Industrial-Estate.pdfFirst Cavite Industrial...
Transcript of Industrial Estatecalabarzon.emb.gov.ph/.../03/Ecoindex-Industrial-Estate.pdfFirst Cavite Industrial...
Industrial Estate Members’ Profile
First Cavite
Industrial Estate
Laguna International
Industrial Park
Light Industry &
Science Park I
Carmelray Industrial
Park 1
Calamba Premiere
International Park
Light Industry &
Science Park II
Carmelray Industrial
Park 2
First Philippine
Industrial Park Light Industry &
Science Park III
Light Industry &
Science Park IV
LIMA Technology
Center
NAME OF ECOZONE Light Industry & Science Park I
LOCATION Diezmo, Cabuyao, Laguna
DEVELOPER / OPERATOR Science Park of the Philippines Inc. / LISP I Locators’ Association, Inc.
TOTAL AREA (In Hectares) 177
TOTAL NUMBER OF LOCATORS 70
CAPACITY OF WTP (CU.M/DAY) 10,000
VOLUME OF WASTEWATER (CUBIC/DAY) 6,200
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 6,200
TYPE OF TREATMENT FACILITY Activated Sludge Process
PARAMETERS SAMPLED/ ANALYZED BOD, Fecal Coliform, Ammonia, Nitrate, Phosphate Surfactants, Oil and Grease, Cadmium, Chromium, Copper, Lead, Nickel, Iron
RECEIVING BODY OF WATER SAN CRISTOBAL RIVER
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
UPSTREAM SAMPLING
POINT
DOWNSTREAM SAMPLING
POINT
EFFLUENT OUTFALL
Light Industry &
Science Park IBack to
map
Light Industry & Science Park I Centralized Wastewater Treatment Plant
Back
CWTP ICWTP II
DATEBOD COD TSS Color
Temp rise pH
O & G Lead Copper Nickel Zinc MBAS Cr+6 Cd As Hg
(mg/L) (mg/L) (mg/L) (PCU) (ºC) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L)
1/22/2018 7 21 7 10 28 7.4 <1.0 <0.01 <0.005 <0.02 <0.003 <0.10 <0.01 <0.003 <0.001 <0.0001
2/07/2018 <1 30 1 15 29 8.1 <1.0 <0.01 <0.005 <0.02 <0.003 <0.10 <0.01 <0.003 <0.001 <0.0001
3/02/2018 18 39 28 50 28 7.9 <1.0 <0.01 <0.005 <0.02 <0.003 <0.10 <0.01 <0.003 0.007 <0.0001
4/04/2018 23 46 49 50 30 7.5 <1.0 <0.01 <0.005 <0.02 0.046 0.25 <0.01 <0.003 <0.001 <0.0001
5/04/2018 19 37 11 50 28 7.6 <1.0 <0.01 <0.005 <0.02 0.114 0.13 <0.01 <0.003 <0.001 <0.0001
6/06/2018 3 29 3 25 29 7.4 <1.0 <0.01 <0.005 <0.02 <0.003 <0.26 <0.01 <0.003 0.007 <0.0001
7/04/2018 <1.0 6 9 50 30 7.8 <1.0 <0.01 <0.005 <0.02 0.058 0.27 <0.01 <0.003 <0.001 <0.0001
8/03/2018 10 49 42 25 30 8.2 <1.0 <0.01 <0.005 <0.02 0.047 0.16 <0.01 <0.003 <0.001 <0.0001
9/24/2018 4 29 18 50 28 7.8 <1.0 <0.01 <0.005 <0.02 <0.003 <0.10 <0.01 <0.003 0.007 <0.0001
10/24/2018 10 32 9 10 29 7.9 <1.0 <0.01 <0.005 <0.02 <0.03 <0.10 <0.01 <0.003 <0.001 <0.0001
11/07/2018 11 47 8 15 28 8.2 <1.0 <0.01 <0.005 <0.02 <0.03 0.15 <0.01 <0.003 <0.001 <0.0001
12/06/2018 7 28 14 25 30 8 <1.0 <0.01 <0.005 <0.02 <0.03 <0.10 <0.01 <0.003 <0.001 <0.0001
LISP I UPSTREAM RIVER MONITORING DATA
Back
DATEBOD COD TSS Color
Temp rise pH
O & G Lead Copper Nickel Zinc MBAS Cr+6 Cd As Hg
(mg/L) (mg/L) (mg/L) (PCU) (ºC) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L) (mg/L)
1/22/2018 12 50 5 15 28 7.6 <1.0 <0.02 <0.005 <0.02 <0.003 <0.10 <0.01 <0.003 <0.001 <0.0001
2/07/2018 7 31 2 27 27 8.3 <1.0 <0.02 0.007 0.05 <0.003 0.26 <0.01 <0.003 <0.001 <0.0001
3/02/2018 15 32 16 50 28 7.8 <1.0 <0.01 <0.005 0.05 <0.003 <0.10 <0.01 <0.003 0.007 <0.0001
4/04/2018 8 16 24 50 30 7.4 <1.0 <0.01 <0.005 <0.02 0.02 0.15 <0.01 <0.003 <0.001 <0.0001
5/04/2018 16 30 12 50 29 7.4 <1.0 <0.01 <0.005 <0.02 0.099 0.17 <0.01 <0.003 <0.001 <0.0001
6/06/2018 7 34 7 25 30 7.4 <1.0 <0.01 <0.005 <0.02 <0.003 0.35 <0.01 <0.003 <0.001 <0.0001
7/04/2018 4 48 7 50 30 7.8 <1.0 <0.01 0.014 <0.02 0.116 0.44 <0.01 <0.003 <0.001 <0.0001
8/03/2018 5 46 32 25 30 7.7 <1.0 <0.01 0.023 <0.02 0.03 0.26 <0.01 <0.003 <0.001 <0.0001
9/24/2018 6 34 21 50 28 7.6 <1.0 <0.01 <0.005 <0.02 0.026 <0.10 <0.01 <0.003 0.003 <0.0001
10/24/2018 14 45 14 25 29 7.8 <1.0 <0.01 <0.005 <0.02 <0.03 0.25 <0.01 <0.003 <0.001 <0.0001
11/07/2018 9 45 11 15 29 7.9 <1.0 <0.01 <0.005 <0.02 <0.03 0.15 <0.01 <0.003 <0.001 <0.0001
12/06/2018 9 4 16 25 30 7.9 <1.0 <0.01 <0.005 <0.02 <0.03 0.19 <0.01 <0.003 <0.001 <0.0001
LISP I DOWNSTREAM RIVER MONITORING DATA
Back
NAME OF ECOZONE Light Industry & Science Park II
LOCATION Real & La Mesa, Calamba City, Laguna
DEVELOPER / OPERATOR Science Park of the Philippines Inc. / LISP II Locators’ Association, Inc.
TOTAL AREA (In Hectares) 70.4292
TOTAL NUMBER OF LOCATORS 32
CAPACITY OF WTP (CU.M/DAY) 4,000
VOLUME OF WASTEWATER (CUBIC/DAY) 3,250
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 3,250
TYPE OF TREATMENT FACILITY Activated Sludge Process
PARAMETERS SAMPLED/ ANALYZED BOD, Fecal Coliform, Ammonia, Nitrate, Phosphate Surfactants, Oil and Grease, Cadmium, Chromium, Copper, Lead, Nickel, Iron
RECEIVING BODY OF WATER BARANCA DE SIPIT
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
UPSTREAM SAMPLING
POINT
DOWNSTREAM SAMPLING
POINT
EFFLUENT OUTFALL
Light Industry &
Science Park II
Back to map
Back
Light Industry & Science Park II Centralized Wastewater Treatment Plant
Parameters 08-Jan-18 05-Feb-18 02-Mar-18 02-Apr-18 02-May-18 01-Jun-18 03-Jul-18 01-Aug-18 03-Sep-18 01-Oct-18 06-Nov-18 03-Dec-18
Temp ◦C 24 27 25 27 28 27 7.9 28 26 26 28 28
pH --- 7.7 7.6 7.4 7.6 7.6 7.2 29 7.5 7.3 7.8 7.9 8.2
Color TCU 15 15 10 20 50 25 50 20 15 25 25 10
BOD mg/l <1 10 10 28 18 12 25 10 9 19 7 11
COD mg/l <5 63 17 40 46 56 61 31 26 47 23 64
TSS mg/l 4 3 9 8 2 8 13 13 25 13 10 12
Cr+6 mg/l <0.01 <0.01 <0.01 <0.01 <0.01 <1.0 <0.01 <0.01 <0.01 <0.01 <0.02 <0.01
MBAS mg/l <0.10 0.53 0.79 0.34 0.31 0.13 0.20 <0.1 0.43 1.61 0.43 0.15
O & G mg/l <1.0 <1.0 <1.0 28 <1.0 <1.0 <1.0 <10 <1.0 <1.0 <1.0 <1.0
Cd mg/l <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003
Dis. Cu mg/l <0.005 0.02 0.009 <0.005 <0.005 <0.005 <0.005 0.006 <0.005 <0.005 <0.005 <0.005
Ni mg/l <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.03 <0.03 <0.02
Pb mg/l <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01
Zn mg/l <0.003 0.012 <0.003 <0.003 <0.003 0.081 0.169 <0.003 0.009 <0.003 <0.003 <0.003
LISP II UPSTREAM RIVER MONITORING DATA
Back
Parameters 08-Jan-18 05-Feb-18 02-Mar-18 02-Apr-18 02-May-18 01-Jun-18 03-Jul-18 01-Aug-18 03-Sep-18 01-Oct-18 06-Nov-18 03-Dec-18
Temp ◦C 25 29 28 28 27 29 29 28 27 28 28 27
pH --- 7.6 7.8 7.6 7.4 7.7 7.8 8.1 7.7 7.6 7.5 8 8
Color TCU 5 20 5 10 15 25 3 15 5 50 5 5
BOD mg/l <1 35 2 16 12 11 38 19 17 12 12 15
COD mg/l 15 52 23 47 54 45 50 37 44 43 36 82
TSS mg/l 8 5 6 13 8 7 19 16 27 7 13 14
Cr+6 mg/l <0.01 <1.0 <0.01 <0.01 <0.03 <0.01 <0.01 <0.01 <0.01 <0.01 <0.02 <0.01
MBAS mg/l <0.1 0.45 0.98 1.07 0.60 0.33 0.69 <0.01 0.46 1.54 0.37 0.72
O & G mg/l <1.0 <1.0 <1.0 1.1 <1.0 <1.0 <1.0 <010 <1.0 <1.0 <1.0 <1.0
Cd mg/l <0.003 <0.005 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.004 <0.003
Dis. Cu mg/l <0.005 <0.003 0.03 0.029 0.056 <0.005 0.036 0.024 <0.005 <0.005 0.027 <0.005
Ni mg/l <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02
Pb mg/l <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01
Zn mg/l 0.039 <0.003 0.016 0.032 0.046 0.004 0.241 0.022 0.042 0.133 <0.003 <0.003
LISP II DOWNSTREAM RIVER MONITORING DATA
Back
NAME OF ECOZONE Light Industry & Science Park III
LOCATION San Rafael & Sta Anastacia, Sto. Tomas, Batangas
DEVELOPER / OPERATOR RFM-Science Park of the Philippines Inc./ LISP III Locators’ Association, Inc.
TOTAL AREA (In Hectares) 110.484
TOTAL NUMBER OF LOCATORS 36
CAPACITY OF WTP (CU.M/DAY) 4,000
VOLUME OF WASTEWATER (CUBIC/DAY) 190
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 190
TYPE OF TREATMENT FACILITY Activated Sludge Process
PARAMETERS SAMPLED/ ANALYZED pH, Temp., BOD, COD, Total Coliform, O&G, Color, Surfactant, Heavy Metals
RECEIVING BODY OF WATER SAN JUAN RIVER
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
UPSTREAM SAMPLING
POINT
DOWNSTREAM SAMPLING
POINT
EFFLUENT OUTFALL
Light Industry &
Science Park III
Back to map
Light Industry & Science Park III Centralized Wastewater Treatment Plant
Parameters 08-Jan-18 05-Feb-18 02-Mar-18 02-Apr-18 02-May-18 01-Jun-18 03-Jul-18 01-Aug-18 03-Sep-18 01-Oct-18 06-Nov-18 03-Dec-18
Temp ◦C 27 27 26 25 30 26 27 30 28 26 30 27
pH --- 8 7.9 7.9 7.3 7.6 7.8 7.6 7.8 7.2 7.3 8.1 8.2
Color TCU 2 5 50 15 10 10 10 2 25 5 10 5
BOD mg/l <1 6 9 26 9 10 2 6 4 6 3 14
COD mg/l 46 10 28 30 30 19 15 15 35 29 11 42
TSS mg/l 83 12 12 120 37 19 24 15 23 19 33 18
Cr+6 mg/l <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01
MBAS mg/l 0.20 0.46 0.39 0.19 0.24 0.37 <0.10 <1.0 0.38 0.13 <0.10 0.18
O & G mg/l 3.2 <1.0 <1.0 1.1 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0
Cd mg/l <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003
Dis. Cu mg/l <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005
Ni mg/l <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02
Pb mg/l <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01
Zn mg/l 0.146 0.028 <0.003 0.133 <0.003 <0.003 0.037 <0.003 0.04 0.551 <0.003 <0.003
LISP III UPSTREAM RIVER MONITORING DATA
Back
Parameters 08-Jan-18 05-Feb-18 02-Mar-18 02-Apr-18 02-May-18 01-Jun-18 03-Jul-18 01-Aug-18 03-Sep-18 01-Oct-18 06-Nov-18 03-Dec-18
Temp ◦C 25 29 28 28 27 29 29 28 27 28 28 27
pH --- 8.1 7.8 7.4 7.6 7.8 7.6 7.4 7.7 7.3 7.6 8 7.6
Color TCU 7.6 5 50 15 10 10 10 2 25 5 10 5
BOD mg/l 23 13 15 17 20 17 4 14 3 7 3 23
COD mg/l 36 15 33 47 43 20 21 30 36 48 19 59
TSS mg/l 23 15 14 96 31 19 15 24 29 18 18 14
Cr+6 mg/l <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01
MBAS mg/l 0.20 0.51 0.41 0.37 <0.10 0.41 <0.10 0.56 0.48 <0.01 <0.10 0.21
O & G mg/l 3.4 <1.0 <1.0 1.1 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <0.10 3.7
Cd mg/l <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003 <0.003
Dis. Cu mg/l <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005 <0.005
Ni mg/l <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02 <0.02
Pb mg/l <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01 <0.01
Zn mg/l 0.082 <0.003 <0.003 0.096 <0.003 <0.003 0.021 0.041 0.041 <0.003 <0.003 <0.003
LISP III DOWNSTREAM RIVER MONITORING DATA
Back
NAME OF ECOZONE Light Industry & Science Park IV
LOCATION Malvar, Batangas
DEVELOPER / OPERATOR Science Park of the Philippines Inc.,
TOTAL AREA (In Hectares) 200
TOTAL NUMBER OF LOCATORS No locators yet
CAPACITY OF WTP (CU.M/DAY) 1,000
VOLUME OF WASTEWATER (CUBIC/DAY) 0
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 0
TYPE OF TREATMENT FACILITY Activated Sludge Process
PARAMETERS SAMPLED/ ANALYZED
RECEIVING BODY OF WATER TAAL LAKE
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS B
Discharge of Effluent
CWTP Area
River Sample Location for Baseline
Characterization
Back to map
Back
Parameters 16 January 2019
Temp ◦C 27
pH --- 7.8
Color TCU 5
BOD mg/l <1
COD mg/l <5
TSS mg/l 12
Cr+6 mg/l <0.01
MBAS mg/l 0.14
O & G mg/l <1.0
Cd mg/l <0.003
Dis. Cu mg/l <0.005
Ni mg/l <0.02
LISP IV BASELINE RIVER MONITORING DATA
Back
Parameters 16 January 2019
Hg mg/l <0.0001
Fe mg/l mg/l
Ba mg/l <0.20
As mg/l 0.006
CN- mg/l <0.05
F- mg/l 0.46
Sulfate mg/l 17
Ammonia mg/l <0.03
Nitrate mg/l 0.43
Phosphate mg/l 0.22
Zn mg/l 0.146
Pb mg/l <0.01
NAME OF ECOZONE Carmelray Industrial Park I
LOCATION Canlubang, Calamba City, Laguna
DEVELOPER / OPERATOR Carmelray Industrial Corporation
TOTAL AREA (In Hectares) 434
TOTAL NUMBER OF LOCATORS 59
CAPACITY OF WTP (CU.M/DAY) 14,300
VOLUME OF WASTEWATER (CUBIC/DAY) 3,500
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 3,500
TYPE OF TREATMENT FACILITY Conventional Activated Sludge System
PARAMETERS SAMPLED/ ANALYZED all parameters under DAO 2016-08 including BTEX and nutrients
RECEIVING BODY OF WATER SAN CRISTOBAL RIVER
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
The CWTF operates on an extended aeration activated
system which ensures that effluent meets Class C
Waters Standard. Both influent and effluent feed are
being monitored for DAO-08 Standards.
Environmental Management UnitCarmelray Industrial Park ICanlubang, Calamba, Laguna
CIP I CWTF Effluent Meets Class C Parameters
• Portion of the treated wastewater from CWTF is used to water the
CWTF Complex irrigation needs
• Part of Effluent is impounded in one tank for fish and aquatic breeding
Environmental Management UnitCarmelray Industrial Park ICanlubang, Calamba, Laguna
Drainage Plan
CIP CWTF
Environmental Management UnitCarmelray Industrial Park ICanlubang, Calamba, Laguna
Ambient Water Body Sampling
UPSTREAM
SAMPLING
DOWNSTREAM
SAMPLING
0
20
40
60
80
100
120
140
J F M A M J J A S O N D
Biochemical Oxygen Demand
0
20
40
60
80
100
120
J F M A M J J A S O N D
Total Suspended Solids
0
1
2
3
4
5
6
7
8
9
J F M A M J J A S O N D
pH Range
0
10
20
30
40
50
60
70
J F M A M J J A S O N D
Dissolved Oxygen
Upstream
Downstream
Class C Standards
2018 Cauang Cauang Creek Sample Result (tributary to San Cristobal River, Class C Water
Back to map
NAME OF ECOZONE Carmelray Industrial Park II
LOCATION Punta & Tulo, Calamba City, Laguna
DEVELOPER / OPERATOR Carmelray - JTCI Corporation
TOTAL AREA (In Hectares) 143.0252
TOTAL NUMBER OF LOCATORS 50
CAPACITY OF WTP (CU.M/DAY) 3,200
VOLUME OF WASTEWATER (CUBIC/DAY) 2,000
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 2,000
TYPE OF TREATMENT FACILITY Conventional Activated Sludge System
PARAMETERS SAMPLED/ ANALYZED DAO 35 Parameters and nutrients
RECEIVING BODY OF WATER SAN JUAN RIVER
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
Back to map
Carmelray Industrial Park II Wastewater Treatment Plant
NAME OF ECOZONE First Philippine Industrial Park, Inc. (FPIP)
LOCATION Sto. Tomas, Batangas
DEVELOPER / OPERATOR First Philippine Industrial Park, Inc. (FPIP) / FPIP Utilities, Inc. (operator of WWTP)
TOTAL AREA (In Hectares) 450
TOTAL NUMBER OF LOCATORS 130
CAPACITY OF WTP (CU.M/DAY) 14,500
VOLUME OF WASTEWATER (CUBIC/DAY) 9,800
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 9,800
TYPE OF TREATMENT FACILITY Conventional Activated Sludge Process
PARAMETERS SAMPLED/ ANALYZED pH, temp, BOD5, COD, Total Coliform Count, Oil and Grease, Color, Surfactant, Manganese, Total Suspended Solids, Arsenic, Cadmium, Chromium, Copper, Lead,Nickel, Zinc, Iron, Silica, Mercury
RECEIVING BODY OF WATER SAN JUAN RIVER
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
WWTP-1
Downstream Sampling point
Upstream Sampling point
WWTP-2
Back to map
FPIP
WWTP I
Back
FPIP
WWTP II
Back
Parameters Q1 – Jan. 26, 2018 Q2 – April 13, 2018 Q3 – Aug. 19, 2018 Q4-Nov. 14, 2018
Total Coliform, mpn/100ml <1.8 16,000 <1.8 16,000
pH 7.4 7.6 7.02 7.61
Temperature, C 29.1 29 21.6
BOD5, mg/l 17 25 34 16
COD, mg/l 60 73 65 59
Oil & Grease, mg/l 1.6 2.44 1.1 5
Surfactant, mg/l 0.05 <0.03 0.41 <0.03
Manganese, mg/l <0.05 <0.05 <0.05 <0.05
TSS, mg/l <3 <3 <3 6
Arsenic, mg/l <0.005 <0.005 <0.005 <0.005
Cadmium, mg/l <0.003 <0.008 <0.003 <0.003
Chromium, mg/l <0.01 <0.01 <0.01 <0.01
Copper (as dissolved), mg/l <0.02 <0.02 <0.02 <0.02
Lead, mg/l <0.008 <0.008 <0.008 <0.008
Nickel, mg/l <0.01 <0.01 0.02 <0.01
Mercury <0.001 <0.001 <0.001
Zinc, mg/l 0.04 <0.01 0.04 0.01
Color (true), TCU 5 <5 5 20
Nitrate Nitrogen, mg/l <0.10 <0.10 <0.10 1.9
Iron, mg/l 0.11 <0.02 0.1 <0.05
Chloride, mg/l 57.48 23.48 7.39 30.49
Total Phosphate, mg/l 1.46 3.19 <0.20 2.86
FPIP’s UPSTREAM RIVER MONITORING DATA
Back
Parameters Q1 – Jan. 26, 2018 Q2 – April 13, 2018 Q3 – Aug. 19, 2018 Q4-Nov. 14, 2018
Total Coliform, mpn/100ml <1.8 16,000 <1.8 16,000
pH 7.34 7.72 7.02 7.72
Temperature, C 29.3 29.1 21.6
BOD5, mg/l 21 29 22 18
COD, mg/l 66 78 72 56
Oil & Grease, mg/l 1.7 5 1.6 <1.0
Surfactant, mg/l 0.04 <0.03 0.06 <0.03
Manganese, mg/l <0.05 <0.05 <0.05 <0.05
TSS, mg/l <3 <3 8 14
Arsenic, mg/l <0.005 <0.005 <0.005 <0.005
Cadmium, mg/l <0.003 <0.008 <0.003 <0.003
Chromium, mg/l <0.01 <0.01 <0.01 <0.01
Copper (as dissolved), mg/l <0.02 <0.02 <0.02 <0.02
Lead, mg/l <0.008 <0.008 <0.008 0.008
Nickel, mg/l <0.01 <0.01 <0.01 <0.01
Mercury, mg/l <0.001 <0.001 <0.001
Zinc, mg/l 0.09 <0.01 0.05 0.02
Color (true), TCU 5 <5 10 10
Nitrate Nitrogen, mg/l <0.10 <0.10 <0.10 1.43
Iron, mg/l 0.12 <0.02 <0.05 <0.05
Chloride, mg/l 69.38 28.37 6.9 49.48
Total Phosphate, mg/l 0.93 3.4 <0.20 3.07
FPIP’s DOWNSTREAM RIVER MONITORING DATA
Back
NAME OF ECOZONE First Industrial Township, Inc. (FITI)
LOCATION Tanauan City, Batangas
DEVELOPER / OPERATOR First Industrial Township, Inc. (FITI) / FIT Water, Inc. (operator of WWTP)
TOTAL AREA (In Hectares) 70
TOTAL NUMBER OF LOCATORS 7
CAPACITY OF WTP (CU.M/DAY) 1,700
VOLUME OF WASTEWATER (CUBIC/DAY) 111
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 111
TYPE OF TREATMENT FACILITY Conventional Activated Sludge Process
PARAMETERS SAMPLED/ ANALYZED Total Coliform Count, pH, temperature, BOD5, COD, Oil and Grease, Surfactant, Manganese, TSS, Arsenic, Cadmium, Chromium, Copper, Lead, Nickel, Mercury, Zinc, Color, Nitrate Nitrogen, Iron, Chloride, Total Phosphate
RECEIVING BODY OF WATER SAN JUAN RIVER
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
Back to map
Downstream Sampling point
Upstream Sampling point
Parameters Q1-January 26, 2018 Q2-April 20, 2018 Q3 – August 19, 2018 Q4-November 14, 2018
Total Coliform, mpn/100ml <1.8 <1.8 <1.8 1,600
pH 7.32 7.29 7.29 7.89
Temperature, C 26 29.7 28.8 28.9
BOD5, mg/l 19 16 11 13
COD, mg/l 68 63 73 82
Oil & Grease, mg/l 1.4 <1.0 2 <1.0
Surfactant, mg/l 0.06 0.47 0.03 0.03
Manganese, mg/l <0.05 <0.05 <0.05 <0.05
TSS, mg/l <3 7 6 8
Arsenic, mg/l <0.005 <0.005 <0.005 <0.005
Cadmium, mg/l <0.003 <0.003 <0.003 <0.003
Chromium, mg/l <0.01 <0.01 <0.01 <0.01
Copper (as dissolved), mg/l <0.02 <0.02 <0.02 <0.02
Lead, mg/l <0.008 <0.008 <0.008 <0.008
Nickel, mg/l <0.01 0.08 0.01 <0.01
Mercury <0.001 <0.001 <0.001 <0.001
Zinc, mg/l 0.05 0.03 0.03 <0.01
Color (true), TCU <5 5 20
Nitrate Nitrogen, mg/l <0.10 0.16 <0.10 2.77
Iron, mg/l 0.14 <0.05 0.2 <0.05
Chloride, mg/l 85.98 23.97 6.41 20.12
Total Phosphate, mg/l 4.38 3.46 <0.20 4.64
FITI’s UPSTREAM RIVER MONITORING DATA
Back
Parameters Q1-January 26, 2018 Q2-April 20, 2018 Q3 – August 19, 2018 Q4-November 14, 2018
Total Coliform, mpn/100ml <1.8 16,000 <1.8 16,000
pH 7.43 7.67 7.43 7.51
Temperature, C 26 29.8 28.6 28.5
BOD5, mg/l 17 13 32 34
COD, mg/l 326 63 62 63
Oil & Grease, mg/l 1.3 <1.0 3.2 <1.0
Surfactant, mg/l 0.13 0.87 <0.03 0.03
Manganese, mg/l <0.05 <0.05 <0.05 0.08
TSS, mg/l <3 <3 <3 12
Arsenic, mg/l <0.005 <0.005 <0.005 <0.005
Cadmium, mg/l <0.003 <0.003 <0.003 <0.003
Chromium, mg/l <0.01 <0.01 <0.01 <0.01
Copper (as dissolved), mg/l 0.02 <0.02 <0.02 <0.02
Lead, mg/l <0.008 <0.008 <0.008 <0.008
Nickel, mg/l <0.01 0.07 0.01 <0.01
Mercury, mg/l <0.001 <0.001 <0.001 <0.001
Zinc, mg/l 0.13 0.08 0.05 0.07
Color (true), TCU 5 5 20
Nitrate Nitrogen, mg/l 0.11 0.48 <0.10 1.67
Iron, mg/l 0.56 0.08 0.2 <0.05
Chloride, mg/l 77.9 33.27 7.88 23.24
Total Phosphate, mg/l 2.97 3.5 <0.20 3.83
FITI’s DOWNSTREAM RIVER MONITORING DATA
Back
NAME OF ECOZONE LAGUNA INTERNATIONAL INDUSTRIAL PARK ASSOCIATION INC.
LOCATION BRGY MAMPLASAN, BIÑAN CITY LAGUNA
DEVELOPER / OPERATOR SOLID CORP/SAMSUNG GROUP
TOTAL AREA (In Hectares) 117
TOTAL NUMBER OF LOCATORS 68
CAPACITY OF WTP (CU.M/DAY) 5000
VOLUME OF WASTEWATER (CUBIC/DAY) 490
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 490
TYPE OF TREATMENT FACILITY Activated Sludge
PARAMETERS SAMPLED/ ANALYZED BOD , COD , TSS , OIL & GREASE , COLIFORM
RECEIVING BODY OF WATER SANTA ROSA RIVER
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
LIIP Wastewater Treatment Plant
Back to map
NAME OF ECOZONE Calamba Premiere International Park
LOCATION Batino, Parian and Barandal, Calamba City, Laguna
DEVELOPER / OPERATOR Starworld Corporation
TOTAL AREA (In Hectares) 117.79
TOTAL NUMBER OF LOCATORS 65
CAPACITY OF WTP (CU.M/DAY) 2,000
VOLUME OF WASTEWATER (CUBIC/DAY) 650
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 650
TYPE OF TREATMENT FACILITY Activated Sludge Treatment
PARAMETERS SAMPLED/ ANALYZED
RECEIVING BODY OF WATER San Cristobal River
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
CPIP
Back to map
NAME OF ECOZONE Lima Technology Center
LOCATION San Lucas, Bugtong na Pulo & Inosluban, Lipa City and Santiago & Payapa, Malvar, Batangas
DEVELOPER / OPERATOR Lima Land Inc.
TOTAL AREA (In Hectares) 600
TOTAL NUMBER OF LOCATORS 106
CAPACITY OF WTP (CU.M/DAY) 25,500
VOLUME OF WASTEWATER (CUBIC/DAY) 3,200
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY) 3,200
TYPE OF TREATMENT FACILITY Oxidation Ditch/Sequencing Batch Reactor
PARAMETERS SAMPLED/ ANALYZED 35 parameters
RECEIVING BODY OF WATER San Juan River
CLASSIFICATION OF RECEIVING BODY OF WATER CLASS C
Lima Technology Center Wastewater Treatment Plant
Monitoring Results of Tigiro Creek
Parameters
Biological Oxygen Demand (mg/L) 26
Chemical Oxygen Demand (mg/L) 85
Total Suspended Solid (mg/L) 14
pH 7.81
Color (PCU) 30
Oil & Grease (mg/L) 2.75
Back to map
NAME OF ECOZONE First Cavite Industrial Estate
LOCATIONLangkaan, Dasmariñas, Cavite
DEVELOPER / OPERATOR First Cavite Industrial Estate Inc.
TOTAL AREA (In Hectares) 154.5
TOTAL NUMBER OF LOCATORS 98
CAPACITY OF WTP (CU.M/DAY) No Centralized WWTP
VOLUME OF WASTEWATER (CUBIC/DAY) 3,556
VOLUME OF WASTEWATER DISCHARGED (CUBIC/DAY)3,556
TYPE OF TREATMENT FACILITY N/A
PARAMETERS SAMPLED/ ANALYZED N/A
RECEIVING BODY OF WATERYlang -Ylang River
CLASSIFICATION OF RECEIVING BODY OF WATER Class C
Back to map