INDUSTRIAL CABLES CATALOGUE INSTRUMENTATION CABLES FOUNDATION FIELDBUS CABLES THERMOCOUPLE CABLES CONTROL CABLES Innovation, Commitment, Appreciation, Respect and Excellence W www.saudicable.com

Transcript of INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC...

Page 1: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

INDUSTRIAL CABLES CATALOGUE

INSTRUMENTATION CABLESFOUNDATION FIELDBUS CABLESTHERMOCOUPLE CABLESCONTROL CABLES

Innovation, Commitment, Appreciation, Respect and Excellence W www.saudicable.com

Page 2: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Introduction

Satisfying today’s demands for Power & Telecommunications Systems is the business of Saudi Cable Company (SCC) Group, the Middle East’s foremost provider of technologically advanced cable solutions and services. Conceived in 1975, the company has now come to be globally recognized for its excellence in product design and engineering, as well as its world class total solution services, by various governmental agencies, oil, gas and petrochemical industries and public utilities worldwide. SCC’s factory, located in Industrial City, Jeddah, consists of ultra-modern facilities, high-tech machinery and a well-equipped laboratory, built for conducting various routine and type tests. It operates with a clearly defined and documented Quality System set in accordance with the guidelines of ISO 9001:2008 for all its activities, right from the product design, engineering, to the selection of raw material, suppliers, schedule planning, production and testing, then the delivery of cables, with a policy of total customer satisfaction. SCC’s cable products are manufactured to International Standards, tested and certified by prestigious institutions such as Underwriters Laboratories (UL), British Standards Institution (BSI), International Electrotechnical Commission (IEC), European Standards (EN), Saudi

ARAMCO Material Supply Specification (SAMSS), SABIC (Saudi Basic Industries Companies), Royal Commission for Jubail & Yanbu, Saudi Arabian Standards Organization (SASO), Saudi National Grid – Saudi Electricity Company (SEC), SWCC (Saudi Water Conversion Corporation) Saudi Telecom Company (STC) etc. SCC manufactured cables are approved by all major organizations in Saudi Arabia such as: Saudi National Grid – SEC, SAUDI ARAMCO, SABIC, Royal commission of Jubail and Yanbu, SWCC, STC, and others, as well as in all major organizations in the GCC (Bahrain, Kuwait, Qatar, Oman & United Arab Emirates) and MENA (Middle East and North Africa). This catalogue covers Instrumentation, Foundation Field Bus, Thermocouple, Fire Resistant and Lead Sheathed Cables and gives illustrative technical parameters for each cable. However, this range isn’t restricted since SCC Cables’ true value lies in the adaptation of the products according to the customer requirements and specifications.

Page 3: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

T A B L E O F C O N T E N T S

Pages

Ul 13 / ul 2250, pltc/itc , 90°c / 300v, sunlight & oil resistant, flame retardant 03

Single pair/triad, xlpe/pvc, unshielded, unarmoured instrumentation cable 04

Single pair/triad, xlpe/pvc, shielded, unarmoured instrumentation cable 05

Multi pair/triad, xlpe/pvc, unshielded, unarmoured instrumentation cable 06

Multi pair/triad, xlpe/pvc, unshielded with overall shield, unarmoured instrumentation cable 09

Multi pair/triad, xlpe/pvc with individual and overall shield, unarmoured instrumentation cable 12

Single pair/triad, xlpe/pvc, unshielded, steel wire armoured, instrumentation cable 15

Single pair/triad, xlpe/pvc, shielded, steel wire armoured instrumentation cable 16

Multi pair/triad, xlpe/pvc, unshielded, steel wire armoured instrumentation cable 17

Multi pair/triad, xlpe/pvc, unshielded with overall shield, steel wire armoured instrumentation cable 20

Multi pair/triad, xlpe/pvc with individual and overall shield, steel wire armoured instrumentation cable 23

Foundation fieldbus cable to iec 61158-2 type a. 26

Single pair, xlpe, shielded, unarmoured, foundation fieldbus cable 27

Multi pair, xlpe with individual and overall shield, unarmoured, foundation fieldbus cable 28

Single pair, xlpe, shielded, steel wire armoured, foundation fieldbus cable 29

Multi pair, xlpe with individual and overall shield, steel wire armoured, foundation fieldbus cable 30

Thermocouple cables to ansi mc 96.1 And iec 60584 31

Single pair, xlpe/pvc, unshielded, unarmoured, thermocouple cables 32

Single pair, xlpe/pvc, shielded, unarmoured thermocouple cables 33

Multi pair, xlpe/pvc, unshielded, unarmoured thermocouple cables 34

Multi pair, xlpe/pvc, unshielded with overall shield, unarmoured thermocouple cables 36

Multi pair, xlpe/pvc with individual and overall shield, unarmoured thermocouple cables 38

Single pair, xlpe/pvc, unshielded, steel wire armoured thermocouple cables 40

Single pair, xlpe/pvc, shielded, armouredthermocouple cables 41

Multi pair, xlpe/pvc. unshielded, steel wire armoured thermocouple cables 42

Multi pair, xlpe/pvc, unshielded, with overall shield, steel wire armoured, thermocouple cables 44

Multi pair, xlpe/pvc with individual and overall shield, steel wire armoured thermocouple cables 46

Ul 1277, tc, 90°c / 600v, sunlight & oil resistant, flame retardant 48

Single pair/triad, xlpe/pvc, unshielded, unarmoured instrumentation cable 49

Single pair/triad, xlpe/pvc, shielded unarmoured instrumentation cable 50

Multi pair/triad, xlpe/pvc, unshielded, unarmoured instrumentation cables 51

Multi pair/triad, xlpe/pvc, unshielded with overall shield, unarmoured instrumentation cables 53

Multi pair/triad, xlpe/pvc with individual and overall shield, unarmoured instrumentation cables 55

En 50288-7, 500v, cross linked polyethylene insulated cables (xlpe 90°c) and (pvc 90°c) insulated cables 57

Single pair/triad shielded, unarmoured instrumentation cable 58

Single pair/triad shielded, steel wire armoured instrumentation cable 59

Multi twisted pair/triad, unshielded with overall shield, unarmoured instrumentation cables 60

Multi twisted pair/triad with individual and overall shield, unarmoured instrumentation cable 63

Multi twisted pair/triad, unshielded with overall shield, steel wire armoured instrumentation cable 66

Multi twisted pair/triad with individual and overall shield, steel wire armoured instrumentation cable 69

Single pair/triad shielded, pvc bedded, lead alloy sheathed, pvc bedded, steel wire armoured and pvc sheathed instrumentation cable 72

Multi twisted pair/triad, unshielded, with overall shield, pvc bedded, lead alloy sheathed, pvc bedded, steel wire armoured and pvc sheathed instrumentation cable 73

Multi twisted pair/triad, with individual and overall shield, pvc bedded, lead alloy sheathed, pvc bedded, steel wire armoured, and pvc sheathed instrumentation cable 76

Complete TOC when finished

Page 4: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 03 Industrial Cables

A P P L I C A T I O N

• The cables are recommended for indoor and outdoor installation in dry and wet locations, in cable racks and trays, in conduits and suitable for direct burial.

• For Transmission of analogue and digital signals in instrument and control systems; allowed for use in hazardous classified locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources, e.g. Public mains electricity supply.

A. ELECTRICAL PROPERTIES OF INSTRUMENTATION CABLES – TYPE PLTC/ITC – 300V

Conductor size (AWG) 12 14 16 18

Conductor Resistance @ 20°CPlain Cu

(Ω / km) max.5.63 8.95 14.25 22.80

Tinned Cu 5.83 9.3 14.9 23.6

Mutual Capacitance @ 1 KhzXLPE

(nF/km) max.≤150 ≤150 ≤150 ≤150

PVC ≤250 ≤250 ≤250 ≤250

L/R ratio µH/Ω max. ≤80 ≤60 ≤40 ≤25

Insulation ResistanceXLPE

MΩ – Km min. 30.50 30.50 30.50 30.50PVC

Test Voltage Core/Core (Urms)Core/shield (Urms)

XLPEV max. 1500 1500 1500 1500

PVC

PHYSICAL PROPERTIES

Flame Retardancy Passes UL 1685 vertical tray flame test & IEC 60332-3 Cat. A or C

Sunlight Resistance Passes UL-1581 test (720 hours)

Oil Resistance Passes UL-13 test (Oil I)

Minimum Bending Radius7.5 x Cable Outside Diameter (for unarmoured cables)10 x Cable Outside Diameter (for armoured cables)

Temperature Range (operation)During Operation: -30°C to +90°CDuring Installation: -5°C to +50°C

INSULATION AND JACKET COLOURS

Pair colour Black & White. Other pair colours are available upon request.

Triad colour Black, White and Red. Other triad colours are available upon request.

Jacket colour Black. Other colours are available upon request.

Single & Multipair and Multi-Triple, individual and/or overall screen, PVC- sheath

Cable Features:UnarmouredArmoured

Common Cable Construction:Conductor Type– Plain Copper– Tinned Coated Copper

Insulation Material– XLPE 90°C– PVC 90°C

Unarmoured

Armoured– Galvanised Steel Wires– Double Steel Tape

Jackets– PVC Flame Retardant, Oil and

Sunlight Resistant– Low Smoke Zero Halogen Free

UL 13 / UL 2250, PLTC/ITC , 90°C / 300V, SUNLIGHT & OIL RESISTANT, FLAME RETARDANT

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 5: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 04Industrial Cables

SINGLE PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PC2-J-XFYu XLPE18 0.66 0.90 8.45

5101PC2-J-YaYu PVC 6001PC2-H-XFYu XLPE

16 0.66 1.02 9.3068

01PC2-H-YaYu PVC 8001PC2-I-XFYu XLPE

14 0.66 1.02 10.088

01PC2-I-YaYu PVC 10001PC2-G-XFYu XLPE

12 0.66 1.07 11.0118

01PC2-G-YaYu PVC 130

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01TC2-J-XFYu XLPE18 0.66 1.02 9.10

6901TC2-J-YaYu PVC 8001TC2-H-XFYu XLPE

16 0.66 1.02 9.7588

01TC2-H-YaYu PVC 10001TC2-I-XFYu XLPE

14 0.66 1.02 10.60116

01TC2-I-YaYu PVC 13001TC2-G-XFYu XLPE

12 0.66 1.27 12.10171

01TC2-G-YaYu PVC 190

1234

SINGLE PAIR/TRIAD, XLPE/PVC, UNSHIELDED, UNARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 6: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 05 Industrial Cables

SINGLE PAIR XLPE/PVC SHIELDED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD XLPE/PVC SHIELDED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Screening/Shielding: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PC2-J-XFOSYu XLPE18 0.66 0.90 8.80

5801PC2-J-YaOSYu PVC 6501PC2-H-XFOSYu XLPE

16 0.66 1.02 9.6576

01PC2-H-YaOSYu PVC 8501PC2-I-XFOSYu XLPE

14 0.66 1.02 10.4596

01PC2-I-YaOSYu PVC 11001PC2-G-XFOSYu XLPE

12 0.66 1.02 11.35126

01PC2-G-YaOSYu PVC 140

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01TC2-J-XFOSYu XLPE18 0.66 1.02 9.50

7701TC2-J-YaOSYu PVC 9001TC2-H-XFOSYu XLPE

16 0.66 1.02 10.1096

01TC2-H-YaOSYu PVC 11001TC2-I-XFOSYu XLPE

14 0.66 1.02 10.90124

01TC2-I-YaOSYu PVC 14001TC2-G-XFOSYu XLPE

12 0.66 1.27 12.50180

01TC2-G-YaOSYu PVC 200

12345

SINGLE PAIR/TRIAD, XLPE/PVC, SHIELDED, UNARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300V SUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 7: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 06Industrial Cables

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-J-XFYu XLPE18 2 0.66 1.27 12.50

10802PC2-J-YaYu PVC 12604PC2-J-XFYu XLPE

18 4 0.66 1.27 14.15168

04PC2-J-YaYu PVC 19006PC2-J-XFYu XLPE

18 6 0.66 1.27 16.55231

06PC2-J-YaYu PVC 25008PC2-J-XFYu XLPE

18 8 0.66 1.52 18.90312

08PC2-J-YaYu PVC 33510PC2-J-XFYu XLPE

18 10 0.66 1.52 21.15378

10PC2-J-YaYu PVC 39012PC2-J-XFYu XLPE

18 12 0.66 1.52 21.80431

12PC2-J-YaYu PVC 45016PC2-J-XFYu XLPE

18 16 0.66 1.78 24.60574

16PC2-J-YaYu PVC 67524PC2-J-XFYu XLPE

18 24 0.66 1.78 30.00815

24PC2-J-YaYu PVC 95536PC2-J-XFYu XLPE

18 36 0.66 2.03 34.501183

36PC2-J-YaYu PVC 138502PC2-H-XFYu XLPE

16 2 0.66 1.27 13.40168

02PC2-H-YaYu PVC 17004PC2-H-XFYu XLPE

16 4 0.66 1.27 15.35216

04PC2-H-YaYu PVC 24006PC2-H-XFYu XLPE

16 6 0.66 1.52 18.55322

06PC2-H-YaYu PVC 37008PC2-H-XFYu XLPE

16 8 0.66 1.52 20.60407

08PC2-H-YaYu PVC 46010PC2-H-XFYu XLPE

16 10 0.66 1.52 23.15495

10PC2-H-YaYu PVC 57012PC2-H-XFYu XLPE

16 12 0.66 1.78 24.40598

12PC2-H-YaYu PVC 65016PC2-H-XFYu XLPE

16 16 0.66 1.78 27.00758

16PC2-H-YaYu PVC 87024PC2-H-XFYu XLPE

16 24 0.66 1.78 32.851087

24PC2-H-YaYu PVC 125036PC2-H-XFYu XLPE

16 36 0.66 2.03 38.001586

36PC2-H-YaYu PVC 1820

MULTI PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

12345

MULTI PAIR/TRIAD, XLPE/PVC, UNSHIELDED, UNARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 8: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 07 Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XFYu XLPE18 2 0.66 1.27 13.65

14002TC2-J-YaYu PVC 17504TC2-J-XFYu XLPE

18 4 0.66 1.27 15.60226

04TC2-J-YaYu PVC 27506TC2-J-XFYu XLPE

18 6 0.66 1.27 18.85336

06TC2-J-YaYu PVC 40008TC2-J-XFYu XLPE

18 8 0.66 1.52 20.95425

08TC2-J-YaYu PVC 51010TC2-J-XFYu XLPE

18 10 0.66 1.52 23.55517

10TC2-J-YaYu PVC 62512TC2-J-XFYu XLPE

18 12 0.66 1.52 24.85625

12TC2-J-YaYu PVC 75016TC2-J-XFYu XLPE

18 16 0.66 1.78 27.40793

16TC2-J-YaYu PVC 95024TC2-J-XFYu XLPE

18 24 0.66 1.78 34.01178

24TC2-J-YaYu PVC 139036TC2-J-XFYu XLPE

18 36 0.66 2.03 38.701664

36TC2-J-YaYu PVC 1950

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-I-XFYu XLPE14 2 0.66 1.27 14.70

17502PC2-I-YaYu PVC 20004PC2-I-XFYu XLPE

14 4 0.66 1.27 16.85291

04PC2-I-YaYu PVC 33506PC2-I-XFYu XLPE

14 6 0.66 1.52 20.40433

06PC2-I-YaYu PVC 49508PC2-I-XFYu XLPE

14 8 0.66 1.52 22.75553

08PC2-I-YaYu PVC 60010PC2-I-XFYu XLPE

14 10 0.66 1.78 26.15706

10PC2-I-YaYu PVC 79512PC2-I-XFYu XLPE

14 12 0.66 1.78 27.00815

12PC2-I-YaYu PVC 91016PC2-I-XFYu XLPE

14 16 0.66 1.78 29.801043

16PC2-I-YaYu PVC 117024PC2-I-XFYu XLPE

14 24 0.66 2.03 37.151552

24PC2-I-YaYu PVC 175036PC2-I-XFYu XLPE

14 36 0.66 2.03 42.352215

36PC2-I-YaYu PVC 249002PC2-G-XFYu XLPE

12 2 0.66 1.27 16.20234

02PC2-G-YaYu PVC 28004PC2-G-XFYu XLPE

12 4 0.66 1.52 19.25421

04PC2-G-YaYu PVC 48506PC2-G-XFYu XLPE

12 6 0.66 1.52 22.70598

06PC2-G-YaYu PVC 68008PC2-G-XFYu XLPE

12 8 0.66 1.78 26.0799

08PC2-G-YaYu PVC 90510PC2-G-XFYu XLPE

12 10 0.66 1.78 29.25979

10PC2-G-YaYu PVC 110512PC2-G-XFYu XLPE

12 12 0.66 1.78 30.201138

12PC2-G-YaYu PVC 126016PC2-G-XFYu XLPE

12 16 0.66 2.03 34.01507

16PC2-G-YaYu PVC 166024PC2-G-XFYu XLPE

12 24 0.66 2.03 41.752188

24PC2-G-YaYu PVC 240036PC2-G-XFYu XLPE

12 36 0.66 2.29 48.303212

36PC2-G-YaYu PVC 3500

MULTI TRIAD XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

MULTI PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

Page 9: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 08Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad )

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-H-XFYu XLPE16 2 0.66 1.27 14.80

17802TC2-H-YaYu PVC 21004TC2-H-XFYu XLPE

16 4 0.66 1.52 17.50315

04TC2-H-YaYu PVC 34506TC2-H-XFYu XLPE

16 6 0.66 1.52 20.55441

06TC2-H-YaYu PVC 51008TC2-H-XFYu XLPE

16 8 0.66 1.52 22.90563

08TC2-H-YaYu PVC 65510TC2-H-XFYu XLPE

16 10 0.66 1.78 26.40719

10TC2-H-YaYu PVC 82512TC2-H-XFYu XLPE

16 12 0.66 1.78 27.20830

12TC2-H-YaYu PVC 94016TC2-H-XFYu XLPE

16 16 0.66 1.78 30.101063

16TC2-H-YaYu PVC 121024TC2-H-XFYu XLPE

16 24 0.66 2.03 37.401581

24TC2-H-YaYu PVC 181036TC2-H-XFYu XLPE

16 36 0.66 2.29 43.252309

36TC2-H-YaYu PVC 259002TC2-I-XFYu XLPE

14 2 0.66 1.27 16.20235

02TC2-I-YaYu PVC 27004TC2-I-XFYu XLPE

14 4 0.66 1.52 19.20425

04TC2-I-YaYu PVC 48006TC2-I-XFYu XLPE

14 6 0.66 1.52 22.70603

06TC2-I-YaYu PVC 68008TC2-I-XFYu XLPE

14 8 0.66 1.78 25.90806

08TC2-I-YaYu PVC 91010TC2-I-XFYu XLPE

14 10 0.66 1.78 29.25987

10TC2-I-YaYu PVC 112012TC2-I-XFYu XLPE

14 12 0.66 1.78 30.151148

12TC2-I-YaYu PVC 129016TC2-I-XFYu XLPE

14 16 0.66 2.03 33.901520

16TC2-I-YaYu PVC 171024TC2-I-XFYu XLPE

14 24 0.66 2.03 41.702208

24TC2-I-YaYu PVC 248036TC2-I-XFYu XLPE

14 36 0.66 2.29 48.203242

36TC2-I-YaYu PVC 364002TC2-G-XFYu XLPE 12 2 0.66 1.52 18.50 34002TC2-G-YaYu PVC 38504TC2-G-XFYu XLPE

12 4 0.66 1.52 21.35588

04TC2-G-YaYu PVC 66006TC2-G-XFYu XLPE

12 6 0.66 1.78 25.88874

06TC2-G-YaYu PVC 98008TC2-G-XFYu XLPE

12 8 0.66 1.78 28.961128

08TC2-G-YaYu PVC 125010TC2-G-XFYu XLPE

12 10 0.66 1.78 32.751387

10TC2-G-YaYu PVC 153512TC2-G-XFYu XLPE

12 12 0.66 2.03 34.351662

12TC2-G-YaYu PVC 183016TC2-G-XFYu XLPE

12 16 0.66 2.03 38.102152

16TC2-G-YaYu PVC 237024TC2-G-XFYu XLPE

12 24 0.66 2.29 47.503203

24TC2-G-YaYu PVC 353036TC2-G-XFYu XLPE

12 36 0.66 2.55 54.904706

36TC2-G-YaYu PVC 5190

MULTI TRIAD XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

Page 10: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 09 Industrial Cables

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-J-XFOSYu XLPE18 2 0.66 1.27 12.80

11702PC2-J-YaOSYu PVC 13504PC2-J-XFOSYu XLPE

18 4 0.66 1.27 14.52177

04PC2-J-YaOSYu PVC 20506PC2-J-XFOSYu XLPE

18 6 0.66 1.27 16.90241

06PC2-J-YaOSYu PVC 28508PC2-J-XFOSYu XLPE

18 8 0.66 1.52 19.27323

08PC2-J-YaOSYu PVC 37510PC2-J-XFOSYu XLPE

18 10 0.66 1.52 21.52389

10PC2-J-YaOSYu PVC 45512PC2-J-XFOSYu XLPE

18 12 0.66 1.52 22.18443

12PC2-J-YaOSYu PVC 52016PC2-J-XFOSYu XLPE

18 16 0.66 1.78 24.94586

16PC2-J-YaOSYu PVC 68524PC2-J-XFOSYu XLPE

18 24 0.66 1.78 30.27829

24PC2-J-YaOSYu PVC 97036PC2-J-XFOSYu XLPE

18 36 0.66 2.03 34.891198

36PC2-J-YaOSYu PVC 140502PC2-H-XFOSYu XLPE

16 2 0.66 1.27 13.78144

02PC2-H-YaOSYu PVC 17004PC2-H-XFOSYu XLPE

16 4 0.66 1.27 15.71226

04PC2-H-YaOSYu PVC 26006PC2-H-XFOSYu XLPE

16 6 0.66 1.52 18.90333

06PC2-H-YaOSYu PVC 38508PC2-H-XFOSYu XLPE

16 8 0.66 1.52 20.96418

08PC2-H-YaOSYu PVC 48510PC2-H-XFOSYu XLPE

16 10 0.66 1.52 23.49507

10PC2-H-YaOSYu PVC 58512PC2-H-XFOSYu XLPE

16 12 0.66 1.78 24.74610

12PC2-H-YaOSYu PVC 67016PC2-H-XFOSYu XLPE

16 16 0.66 1.78 27.25771

16PC2-H-YaOSYu PVC 88524PC2-H-XFOSYu XLPE

16 24 0.66 1.78 33.221102

24PC2-H-YaOSYu PVC 126536PC2-H-XFOSYu XLPE

16 36 0.66 2.03 38.331603

36PC2-H-YaOSYu PVC 1840

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

12346 5

MULTI PAIR/TRIAD, XLPE/PVC, UNSHIELDED WITH OVERALL SHIELD, UNARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300V SUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 11: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 10Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-I-XFOSYu XLPE14 2 0.66 1.27 15.03

18402PC2-I-YaOSYu PVC 21204PC2-I-XFOSYu XLPE

14 4 0.66 1.27 17.22300

04PC2-I-YaOSYu PVC 34506PC2-I-XFOSYu XLPE

14 6 0.66 1.52 20.77444

06PC2-I-YaOSYu PVC 50508PC2-I-XFOSYu XLPE

14 8 0.66 1.52 23.11564

08PC2-I-YaOSYu PVC 63510PC2-I-XFOSYu XLPE

14 10 0.66 1.78 26.53719

10PC2-I-YaOSYu PVC 81012PC2-I-XFOSYu XLPE

14 12 0.66 1.78 27.37828

12PC2-I-YaOSYu PVC 93516PC2-I-XFOSYu XLPE

14 16 0.66 1.78 30.181057

16PC2-I-YaOSYu PVC 119024PC2-I-XFOSYu XLPE

14 24 0.66 2.03 37.481568

24PC2-I-YaOSYu PVC 176536PC2-I-XFOSYu XLPE

14 36 0.66 2.03 42.702232

36PC2-I-YaOSYu PVC 251002PC2-G-XFOSYu XLPE

12 2 0.66 1.27 16.57243

02PC2-G-YaOSYu PVC 27504PC2-G-XFOSYu XLPE

12 4 0.66 1.52 19.61432

04PC2-G-YaOSYu PVC 48006PC2-G-XFOSYu XLPE

12 6 0.66 1.52 23.08610

06PC2-G-YaOSYu PVC 67508PC2-G-XFOSYu XLPE

12 8 0.66 1.78 26.32812

08PC2-G-YaOSYu PVC 90010PC2-G-XFOSYu XLPE

12 10 0.66 1.78 29.61993

10PC2-G-YaOSYu PVC 110012PC2-G-XFOSYu XLPE

12 12 0.66 1.78 30.571152

12PC2-G-YaOSYu PVC 127516PC2-G-XFOSYu XLPE

12 16 0.66 2.03 34.321522

16PC2-G-YaOSYu PVC 168524PC2-G-XFOSYu XLPE

12 24 0.66 2.03 42.112205

24PC2-G-YaOSYu PVC 243536PC2-G-XFOSYu XLPE

12 36 0.66 2.29 48.643231

36PC2-G-YaOSYu PVC 3565

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XFOSYu XLPE18 2 0.66 1.27 14.00

14902TC2-J-YaOSYu PVC 17504TC2-J-XFOSYu XLPE

18 4 0.66 1.27 15.97235

04TC2-J-YaOSYu PVC 27506TC2-J-XFOSYu XLPE

18 6 0.66 1.52 19.21347

06TC2-J-YaOSYu PVC 40508TC2-J-XFOSYu XLPE

18 8 0.66 1.52 21.33436

08TC2-J-YaOSYu PVC 51010TC2-J-XFOSYu XLPE

18 10 0.66 1.78 23.91529

10TC2-J-YaOSYu PVC 62012TC2-J-XFOSYu XLPE

18 12 0.66 1.78 25.21637

12TC2-J-YaOSYu PVC 74516TC2-J-XFOSYu XLPE

18 16 0.66 1.78 27.75806

16TC2-J-YaOSYu PVC 94524TC2-J-XFOSYu XLPE

18 24 0.66 2.03 34.381193

24TC2-J-YaOSYu PVC 139536TC2-J-XFOSYu XLPE

18 36 0.66 2.03 39.081680

36TC2-J-YaOSYu PVC 197002TC2-H-XFOSYu XLPE

16 2 0.66 1.27 15.13187

02TC2-H-YaOSYu PVC 21504TC2-H-XFOSYu XLPE

16 4 0.66 1.52 17.86325

04TC2-H-YaOSYu PVC 35006TC2-H-XFOSYu XLPE

16 6 0.66 1.52 20.91452

06TC2-H-YaOSYu PVC 52008TC2-H-XFOSYu XLPE

16 8 0.66 1.78 23.28574

08TC2-H-YaOSYu PVC 66010TC2-H-XFOSYu XLPE

16 10 0.66 1.78 26.72731

10TC2-H-YaOSYu PVC 84012TC2-H-XFOSYu XLPE

16 12 0.66 1.78 27.57843

12TC2-H-YaOSYu PVC 97016TC2-H-XFOSYu XLPE

16 16 0.66 2.03 30.411077

16TC2-H-YaOSYu PVC 123524TC2-H-XFOSYu XLPE

16 24 0.66 2.03 37.771597

24TC2-H-YaOSYu PVC 183036TC2-H-XFOSYu XLPE

16 36 0.66 2.29 43.582327

36TC2-H-YaOSYu PVC 2610

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

MULTI TRIAD XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

Page 12: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 11 Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-I-XFOSYu XLPE14 2 0.66 1.27 16.55

24502TC2-I-YaOSYu PVC 28004TC2-I-XFOSYu XLPE

14 4 0.66 1.52 19.58435

04TC2-I-YaOSYu PVC 49006TC2-I-XFOSYu XLPE

14 6 0.66 1.52 23.05615

06TC2-I-YaOSYu PVC 69508TC2-I-XFOSYu XLPE

14 8 0.66 1.78 26.30819

08TC2-I-YaOSYu PVC 92510TC2-I-XFOSYu XLPE

14 10 0.66 1.78 29.581001

10TC2-I-YaOSYu PVC 112512TC2-I-XFOSYu XLPE

14 12 0.66 1.78 30.531162

12TC2-I-YaOSYu PVC 128516TC2-I-XFOSYu XLPE

14 16 0.66 2.03 34.281535

16TC2-I-YaOSYu PVC 172524TC2-I-XFOSYu XLPE

14 24 0.66 2.03 42.102225

24TC2-I-YaOSYu PVC 250036TC2-I-XFOSYu XLPE

14 36 0.66 2.29 48.583261

36TC2-I-YaOSYu PVC 366002TC2-G-XFOSYu XLPE

12 2 0.66 1.52 18.83351

02TC2-G-YaOSYu PVC 39504TC2-G-XFOSYu XLPE

12 4 0.66 1.52 21.71600

04TC2-G-YaOSYu PVC 66506TC2-G-XFOSYu XLPE

12 6 0.66 1.78 26.24887

06TC2-G-YaOSYu PVC 98508TC2-G-XFOSYu XLPE

12 8 0.66 1.78 29.321141

08TC2-G-YaOSYu PVC 126510TC2-G-XFOSYu XLPE

12 10 0.66 1.78 33.101401

10TC2-G-YaOSYu PVC 155012TC2-G-XFOSYu XLPE

12 12 0.66 2.03 34.711677

12TC2-G-YaOSYu PVC 185516TC2-G-XFOSYu XLPE

12 16 0.66 2.03 38.412168

16TC2-G-YaOSYu PVC 239524TC2-G-XFOSYu XLPE

12 24 0.66 2.29 47.873222

24TC2-G-YaOSYu PVC 355536TC2-G-XFOSYu XLPE

12 36 0.66 2.55 55.284727

36TC2-G-YaOSYu PVC 5215

MULTI TRIAD XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

Page 13: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 12Industrial Cables

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-J-XFISYu XLPE18 2 0.66 1.27 13.39

13602PC2-J-YaISYu PVC 15504PC2-J-XFISYu XLPE

18 4 0.66 1.27 15.23212

04PC2-J-YaISYu PVC 24006PC2-J-XFISYu XLPE

18 6 0.66 1.52 18.30312

06PC2-J-YaISYu PVC 35508PC2-J-XFISYu XLPE

18 8 0.66 1.52 20.28391

08PC2-J-YaISYu PVC 44510PC2-J-XFISYu XLPE

18 10 0.66 1.52 22.70473

10PC2-J-YaISYu PVC 53512PC2-J-XFISYu XLPE

18 12 0.66 1.52 23.40543

12PC2-J-YaISYu PVC 61516PC2-J-XFISYu XLPE

18 16 0.66 1.78 26.32719

16PC2-J-YaISYu PVC 82024PC2-J-XFISYu XLPE

18 24 0.66 1.78 32.031026

24PC2-J-YaISYu PVC 117036PC2-J-XFISYu XLPE

18 36 0.66 2.03 36.951491

36PC2-J-YaISYu PVC 169502PC2-H-XFISYu XLPE

16 2 0.66 1.27 14.40163

02PC2-H-YaISYu PVC 19004PC2-H-XFISYu XLPE

16 4 0.66 1.27 16.45261

04PC2-H-YaISYu PVC 31006PC2-H-XFISYu XLPE

16 6 0.66 1.52 19.81385

06PC2-H-YaISYu PVC 45508PC2-H-XFISYu XLPE

16 8 0.66 1.52 22.02486

08PC2-H-YaISYu PVC 57510PC2-H-XFISYu XLPE

16 10 0.66 1.78 25.26621

10PC2-H-YaISYu PVC 73512PC2-H-XFISYu XLPE

16 12 0.66 1.78 26.05712

12PC2-H-YaISYu PVC 84616PC2-H-XFISYu XLPE

16 16 0.66 1.78 28.69905

16PC2-H-YaISYu PVC 107524PC2-H-XFISYu XLPE

16 24 0.66 2.03 35.581340

24PC2-H-YaISYu PVC 159036PC2-H-XFISYu XLPE

16 36 0.66 2.03 40.481896

36PC2-H-YaISYu PVC 2255

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

12356 47

MULTI PAIR/TRIAD, XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD, UNARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300V SUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 14: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 13 Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-I-XFISYu XLPE14 2 0.66 1.27 15.67

20502PC2-I-YaISYu PVC 23504PC2-I-XFISYu XLPE

14 4 0.66 1.52 18.52358

04PC2-I-YaISYu PVC 41506PC2-I-XFISYu XLPE

14 6 0.66 1.52 21.73501

06PC2-I-YaISYu PVC 58008PC2-I-XFISYu XLPE

14 8 0.66 1.78 24.77667

08PC2-I-YaISYu PVC 74010PC2-I-XFISYu XLPE

14 10 0.66 1.78 27.82812

10PC2-I-YaISYu PVC 94012PC2-I-XFISYu XLPE

14 12 0.66 1.78 28.70938

12PC2-I-YaISYu PVC 108516PC2-I-XFISYu XLPE

14 16 0.66 1.78 31.691201

16PC2-I-YaISYu PVC 139024PC2-I-XFISYu XLPE

14 24 0.66 2.03 39.411783

24PC2-I-YaISYu PVC 206036PC2-I-XFISYu XLPE

14 36 0.66 2.29 45.502603

36PC2-I-YaISYu PVC 301002PC2-G-XFISYu XLPE

12 2 0.66 1.52 17.77283

02PC2-G-YaISYu PVC 30004PC2-G-XFISYu XLPE

12 4 0.66 1.52 20.43471

04PC2-G-YaISYu PVC 53506PC2-G-XFISYu XLPE

12 6 0.66 1.52 24.10667

06PC2-G-YaISYu PVC 75508PC2-G-XFISYu XLPE

12 8 0.66 1.78 27.49888

08PC2-G-YaISYu PVC 100510PC2-G-XFISYu XLPE

12 10 0.66 1.78 30.971086

10PC2-G-YaISYu PVC 123012PC2-G-XFISYu XLPE

12 12 0.66 1.78 31.991263

12PC2-G-YaISYu PVC 142516PC2-G-XFISYu XLPE

12 16 0.66 2.03 35.921669

16PC2-G-YaISYu PVC 188524PC2-G-XFISYu XLPE 12 24 0.66 2.29 44.70 247524PC2-G-YaISYu PVC 279536PC2-G-XFISYu XLPE

12 36 0.66 2.29 51.023552

36PC2-G-YaISYu PVC 4010

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XFISYu XLPE18 2 0.66 1.27 15.19

17202TC2-J-YaISYu PVC 19504TC2-J-XFISYu XLPE

18 4 0.66 1.52 17.93244

04TC2-J-YaISYu PVC 33506TC2-J-XFISYu XLPE

18 6 0.66 1.52 21.00406

06TC2-J-YaISYu PVC 46508TC2-J-XFISYu XLPE

18 8 0.66 1.52 23.38512

08TC2-J-YaISYu PVC 58510TC2-J-XFISYu XLPE

18 10 0.66 1.78 26.84654

10TC2-J-YaISYu PVC 75012TC2-J-XFISYu XLPE

18 12 0.66 1.78 27.69750

12TC2-J-YaISYu PVC 86016TC2-J-XFISYu XLPE

18 16 0.66 1.78 30.55952

16TC2-J-YaISYu PVC 109024TC2-J-XFISYu XLPE

18 24 0.66 2.03 37.951410

24TC2-J-YaISYu PVC 161536TC2-J-XFISYu XLPE

18 36 0.66 2.29 43.792046

36TC2-J-YaISYu PVC 2345

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

MULTI TRIAD XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

Page 15: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 14Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-H-XFISYu XLPE16 2 0.66 1.27 16.41

21202TC2-H-YaISYu PVC 24504TC2-H-XFISYu XLPE

16 4 0.66 1.52 19.41369

04TC2-H-YaISYu PVC 43006TC2-H-XFISYu XLPE

16 6 0.66 1.52 22.83516

06TC2-H-YaISYu PVC 60008TC2-H-XFISYu XLPE

16 8 0.66 1.78 26.04687

08TC2-H-YaISYu PVC 80010TC2-H-XFISYu XLPE

16 10 0.66 1.78 29.29836

10TC2-H-YaISYu PVC 97512TC2-H-XFISYu XLPE

16 12 0.66 1.78 30.23965

12TC2-H-YaISYu PVC 112516TC2-H-XFISYu XLPE

16 16 0.66 1.78 33.421234

16TC2-H-YaISYu PVC 144024TC2-H-XFISYu XLPE

16 24 0.66 2.03 41.611832

24TC2-H-YaISYu PVC 213536TC2-H-XFISYu XLPE

16 36 0.66 2.29 48.072672

36TC2-H-YaISYu PVC 311502TC2-I-XFISYu XLPE

14 2 0.66 1.52 18.47290

02TC2-I-YaISYu PVC 33504TC2-I-XFISYu XLPE

14 4 0.66 1.52 21.27481

04TC2-I-YaISYu PVC 55006TC2-I-XFISYu XLPE

14 6 0.66 1.78 25.69709

06TC2-I-YaISYu PVC 81508TC2-I-XFISYu XLPE

14 8 0.66 1.78 28.70905

08TC2-I-YaISYu PVC 104010TC2-I-XFISYu XLPE

14 10 0.66 1.78 32.371107

10TC2-I-YaISYu PVC 127012TC2-I-XFISYu XLPE

14 12 0.66 1.78 33.441286

12TC2-I-YaISYu PVC 147516TC2-I-XFISYu XLPE

14 16 0.66 2.03 37.561699

16TC2-I-YaISYu PVC 195024TC2-I-XFISYu XLPE

14 24 0.66 2.29 46.792519

24TC2-I-YaISYu PVC 289036TC2-I-XFISYu XLPE

14 36 0.66 2.55 54.013675

36TC2-I-YaISYu PVC 421502TC2-G-XFISYu XLPE

12 2 0.66 1.52 20.37380

02TC2-G-YaISYu PVC 43004TC2-G-XFISYu XLPE

12 4 0.66 1.52 23.57649

04TC2-G-YaISYu PVC 73006TC2-G-XFISYu XLPE

12 6 0.66 1.78 28.54960

06TC2-G-YaISYu PVC 108008TC2-G-XFISYu XLPE

12 8 0.66 1.78 31.971235

08TC2-G-YaISYu PVC 138510TC2-G-XFISYu XLPE

12 10 0.65 2.03 36.691558

10TC2-G-YaISYu PVC 175012TC2-G-XFISYu XLPE

12 12 0.65 2.03 37.911815

12TC2-G-YaISYu PVC 203516TC2-G-XFISYu XLPE

12 16 0.66 2.03 42.022345

16TC2-G-YaISYu PVC 263024TC2-G-XFISYu XLPE 12 24 0.66 2.55 53.04 354924TC2-G-YaISYu PVC 390536TC2-G-XFISYu XLPE

12 36 0.66 2.55 60.665111

36TC2-G-YaISYu PVC 5725

MULTI TRIAD XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

Page 16: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 15 Industrial Cables

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

5. Armour: Galvanised Round Steel Wires.

6. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SINGLE PAIR XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Dimensions of Galvanised Double Steel Tape Armour are available upon request. 4.) Other jacket materials are available upon request. 5.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PC2-J-XFSWYu XLPE18 0.66 0.90 0.90 1.02 12.40

22401PC2-J-YaSWYu PVC 23501PC2-H-XFSWYu XLPE

16 0.66 1.02 0.90 1.02 13.25262

01PC2-H-YaSWYu PVC 27501PC2-I-XFSWYu XLPE

14 0.66 1.02 0.90 1.02 14.00297

01PC2-I-YaSWYu PVC 31001PC2-G-XFSWYu XLPE

12 0.66 1.02 0.90 1.27 15.50368

01PC2-G-YaSWYu PVC 390

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01TC2-J-XFSWYu XLPE18 0.66 1.02 0.90 1.02 13.10

25701TC2-J-YaSWYu PVC 27001TC2-H-XFSWYu XLPE

16 0.66 1.02 0.90 1.02 13.70289

01TC2-H-YaSWYu PVC 30501TC2-I-XFSWYu XLPE

14 0.66 1.02 0.90 1.02 15.10354

01TC2-I-YaSWYu PVC 37501TC2-G-XFSWYu XLPE

12 0.66 1.02 0.90 1.27 16.60451

01TC2-G-YaSWYu PVC 470

12346 5

SINGLE PAIR/TRIAD, XLPE/PVC, UNSHIELDED, STEEL WIRE ARMOURED, INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 17: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 16Industrial Cables

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Screening/Shielding : Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

6. Armour: Galvanised Round Steel Wires.7. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Black).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SINGLE PAIR XLPE/PVC SHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD XLPE/PVC SHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PC2-J-XFOSSWYu XLPE18 0.66 1.02 0.90 1.02 13.00

25001PC2-J-YaOSSWYu PVC 26501PC2-H-XFOSSWYu XLPE

16 0.66 1.02 0.90 1.02 13.60277

01PC2-H-YaOSSWYu PVC 29001PC2-I-XFOSSWYu XLPE

14 0.66 1.02 0.90 1.02 14.40317

01PC2-I-YaOSSWYu PVC 33501PC2-G-XFOSSWYu XLPE

12 0.66 1.27 0.90 1.27 16.35412

01PC2-G-YaOSSWYu PVC 433

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01TC2-J-XFOSSWYu XLPE18 0.66 1.02 0.90 1.02 13.40

27201TC2-J-YaOSSWYu PVC 28501TC2-H-XFOSSWYu XLPE

16 0.66 1.02 0.90 1.02 14.10309

01TC2-H-YaOSSWYu PVC 32001TC2-I-XFOSSWYu XLPE

14 0.66 1.02 0.90 1.27 15.40370

01TC2-I-YaOSSWYu PVC 39501TC2-G-XFOSSWYu XLPE

12 0.66 1.27 0.90 1.27 16.90468

01TC2-G-YaOSSWYu PVC 495

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Dimensions of Galvanised Double Steel Tape Armour are available upon request. 4.) Other jacket materials are available upon request. 5.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

12367 5 4

SINGLE PAIR/TRIAD, XLPE/PVC, SHIELDED, STEEL WIRE ARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 18: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 17 Industrial Cables

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

MULTI PAIR XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-J-XSWFYu XLPE18 2 0.66 1.27 0.90 1.27 16.90

39602PC2-J-YaSWYu PVC 41504PC2-J-XFSWYu XLPE

18 4 0.66 1.27 0.90 1.27 18.60497

04PC2-J-YaSWYu PVC 52506PC2-J-XFSWYu XLPE

18 6 0.66 1.27 1.25 1.27 21.70719

06PC2-J-YaSWYu PVC 76508PC2-J-XFSWYu XLPE

18 8 0.66 1.52 1.60 1.27 24.801003

08PC2-J-YaSWYu PVC 104010PC2-J-XFSWYu XLPE

18 10 0.66 1.52 1.60 1.27 27.001149

10PC2-J-YaSWYu PVC 121512PC2-J-XFSWYu XLPE

18 12 0.66 1.52 1.60 1.27 27.701223

12PC2-J-YaSWYu PVC 129016PC2-J-XFSWYu XLPE

18 16 0.66 1.78 2.0 1.27 31.251666

16PC2-J-YaSWYu PVC 175524PC2-J-XFSWYu XLPE

18 24 0.66 1.78 2.0 1.27 36.602144

24PC2-J-YaSWYu PVC 227536PC2-J-XFSWYu XLPE

18 36 0.66 2.03 2.50 1.27 42.202740

36PC2-J-YaSWYu PVC 2900

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers if required) and wrapped with a polyester wrapping tape.

5. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

6. Armour: Galvanised Round Steel Wires.7. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Black).

12347 6 5

MULTI PAIR/TRIAD, XLPE/PVC, UNSHIELDED, STEEL WIRE ARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 19: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 18Industrial Cables

MULTI PAIR XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-H-XFSWYu XLPE16 2 0.66 1.27 0.90 1.27 17.90

44402PC2-H-YaSWYu PVC 47004PC2-H-XFSWYu XLPE

16 4 0.66 1.27 1.25 1.27 20.50666

04PC2-H-YaSWYu PVC 70006PC2-H-XFSWYu XLPE

16 6 0.66 1.52 1.25 1.27 23.70875

06PC2-H-YaSWYu PVC 92008PC2-H-XFSWYu XLPE

16 8 0.66 1.52 1.60 1.27 26.501158

08PC2-H-YaSWYu PVC 122010PC2-H-XFSWYu XLPE

16 10 0.66 1.52 1.60 1.27 29.001362

10PC2-H-YaSWYu PVC 142012PC2-H-XFSWYu XLPE

16 12 0.66 1.78 2.0 1.27 31.101450

12PC2-H-YaSWYu PVC 152016PC2-H-XFSWYu XLPE

16 16 0.66 1.78 2.0 1.27 33.601942

16PC2-H-YaSWYu PVC 205024PC2-H-XFSWYu XLPE

16 24 0.66 1.78 2.50 1.52 40.502555

24PC2-H-YaSWYu PVC 261036PC2-H-XFSWYu XLPE

16 36 0.66 2.03 2.50 1.52 46.173355

36PC2-H-YaSWYu PVC 356002PC2-I-XFSWYu XLPE

14 2 0.66 1.27 1.25 1.27 19.83611

02PC2-I-YaSWYu PVC 63004PC2-I-XFSWYu XLPE

14 4 0.66 1.27 1.25 1.27 22.0790

04PC2-I-YaSWYu PVC 83006PC2-I-XFSWYu XLPE

14 6 0.66 1.52 1.60 1.27 26.301183

06PC2-I-YaSWYu PVC 122508PC2-I-XFSWYu XLPE

14 8 0.66 1.52 1.60 1.27 28.621383

08PC2-I-YaSWYu PVC 145510PC2-I-XFSWYu XLPE

14 10 0.66 1.52 2.0 1.27 32.841859

10PC2-I-YaSWYu PVC 194512PC2-I-XFSWYu XLPE

14 12 0.66 1.78 2.0 1.27 33.702024

12PC2-I-YaSWYu PVC 210016PC2-I-XFSWYu XLPE

14 16 0.66 1.78 2.0 1.27 36.502372

16PC2-I-YaSWYu PVC 250024PC2-I-XFSWYu XLPE

14 24 0.66 1.78 2.5 1.52 45.303455

24PC2-I-YaSWYu PVC 361136PC2-I-XFSWYu XLPE

14 36 0.66 2.03 2.5 1.52 50.504410

36PC2-I-YaSWYu PVC 459002PC2-G-XFSWYu XLPE

12 2 0.66 1.27 1.25 1.27 21.35710

02PC2-G-YaSWYu PVC 74504PC2-G-XFSWYu XLPE

12 4 0.66 1.52 1.60 1.27 25.121115

04PC2-G-YaSWYu PVC 117006PC2-G-XFSWYu XLPE

12 6 0.66 1.52 1.60 1.27 28.601428

06PC2-G-YaSWYu PVC 151008PC2-G-XFSWYu XLPE

12 8 0.66 1.78 2.0 1.27 32.631951

08PC2-G-YaSWYu PVC 204010PC2-G-XFSWYu XLPE

12 10 0.66 1.78 2.0 1.27 35.922279

10PC2-G-YaSWYu PVC 238512PC2-G-XFSWYu XLPE

12 12 0.66 1.78 2.0 1.27 36.902495

12PC2-G-YaSWYu PVC 259016PC2-G-XFSWYu XLPE

12 16 0.66 2.03 2.50 1.27 41.633040

16PC2-G-YaSWYu PVC 318024PC2-G-XFSWYu XLPE

12 24 0.66 2.03 2.50 1.52 49.954145

24PC2-G-YaSWYu PVC 431536PC2-G-XFSWYu XLPE

12 36 0.66 2.29 2.50 1.52 56.475505

36PC2-G-YaSWYu PVC 5710

Page 20: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 19 Industrial Cables

MULTI TRIAD XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XSWFYu XLPE18 2 0.66 1.27 0.90 1.27 18.10

45602TC2-J-YaSWYu PVC 48504TC2-J-XFSWYu XLPE

18 4 0.66 1.27 1.25 1.27 20.77687

04TC2-J-YaSWYu PVC 73006TC2-J-XFSWYu XLPE

18 6 0.66 1.52 1.60 1.27 24.721027

06TC2-J-YaSWYu PVC 107008TC2-J-XFSWYu XLPE

18 8 0.66 1.52 1.60 1.27 26.841195

08TC2-J-YaSWYu PVC 125010TC2-J-XFSWYu XLPE

18 10 0.66 1.52 1.60 1.27 29.421384

10TC2-J-YaSWYu PVC 147512TC2-J-XFSWYu XLPE

18 12 0.66 1.78 2.0 1.27 31.521719

12TC2-J-YaSWYu PVC 182516TC2-J-XFSWYu XLPE

18 16 0.66 1.78 2.0 1.27 34.062005

16TC2-J-YaSWYu PVC 214024TC2-J-XFSWYu XLPE

18 24 0.66 2.03 2.50 1.27 41.703005

24TC2-J-YaSWYu PVC 288036TC2-J-XFSWYu XLPE

18 36 0.66 2.03 2.50 1.52 46.953814

36TC2-J-YaSWYu PVC 375002TC2-H-XFSWYu XLPE

16 2 0.66 1.27 1.25 1.27 19.93614

02TC2-H-YaSWYu PVC 66004TC2-H-XFSWYu XLPE

16 4 0.66 1.52 1.25 1.27 22.67841

04TC2-H-YaSWYu PVC 89606TC2-H-XFSWYu XLPE

16 6 0.66 1.52 1.60 1.27 26.421192

06TC2-H-YaSWYu PVC 128008TC2-H-XFSWYu XLPE

16 8 0.66 1.52 1.60 1.27 28.801410

08TC2-H-YaSWYu PVC 149010TC2-H-XFSWYu XLPE

16 10 0.66 1.78 2.0 1.27 33.031899

10TC2-H-YaSWYu PVC 198012TC2-H-XFSWYu XLPE

16 12 0.66 1.78 2.0 1.27 33.882041

12TC2-H-YaSWYu PVC 216016TC2-H-XFSWYu XLPE

16 16 0.66 1.78 2.0 1.27 36.722410

16TC2-H-YaSWYu PVC 254524TC2-H-XFSWYu XLPE

16 24 0.66 2.03 2.50 1.52 45.613345

24TC2-H-YaSWYu PVC 355036TC2-H-XFSWYu XLPE

16 36 0.66 2.29 2.50 1.52 51.414255

36TC2-H-YaSWYu PVC 456502TC2-I-XFSWYu XLPE

14 2 0.66 1.27 1.25 1.27 21.35711

02TC2-I-YaSWYu PVC 74504TC2-I-XFSWYu XLPE

14 4 0.66 1.52 1.60 1.27 25.101118

04TC2-I-YaSWYu PVC 117506TC2-I-XFSWYu XLPE

14 6 0.66 1.52 1.60 1.27 28.561450

06TC2-I-YaSWYu PVC 151008TC2-I-XFSWYu XLPE

14 8 0.66 1.78 2.0 1.27 32.601975

08TC2-I-YaSWYu PVC 205510TC2-I-XFSWYu XLPE

14 10 0.66 1.78 2.0 1.27 35.892305

10TC2-I-YaSWYu PVC 241012TC2-I-XFSWYu XLPE

14 12 0.66 1.78 2.0 1.27 36.842495

12TC2-I-YaSWYu PVC 262016TC2-I-XFSWYu XLPE

14 16 0.66 2.03 2.50 1.27 41.593050

16TC2-I-YaSWYu PVC 321524TC2-I-XFSWYu XLPE

14 24 0.66 2.03 2.50 1.52 49.904155

24TC2-I-YaSWYu PVC 440536TC2-I-XFSWYu XLPE

14 36 0.66 2.29 2.50 1.52 56.415948

36TC2-I-YaSWYu PVC 586502TC2-G-XFSWYu XLPE

12 2 0.66 1.52 1.25 1.27 23.64892

02TC2-G-YaSWYu PVC 93504TC2-G-XFSWYu XLPE

12 4 0.66 1.52 1.60 1.27 27.221361

04TC2-G-YaSWYu PVC 142506TC2-G-XFSWYu XLPE

12 6 0.66 1.78 2.0 1.27 32.552025

06TC2-G-YaSWYu PVC 211508TC2-G-XFSWYu XLPE

12 8 0.66 1.78 2.0 1.27 35.632426

08TC2-G-YaSWYu PVC 251510TC2-G-XFSWYu XLPE

12 10 0.66 1.78 2.50 1.27 40.402855

10TC2-G-YaSWYu PVC 297512TC2-G-XFSWYu XLPE

12 12 0.66 2.03 2.50 1.27 42.023225

12TC2-G-YaSWYu PVC 337016TC2-G-XFSWYu XLPE

12 16 0.66 2.03 2.50 1.52 46.253950

16TC2-G-YaSWYu PVC 414024TC2-G-XFSWYu XLPE

12 24 0.66 2.29 2.50 1.52 55.705440

24TC2-G-YaSWYu PVC 573036TC2-G-XFSWYu XLPE

12 36 0.66 2.55 2.50 1.90 63.907440

36C2-G-YaSWYu PVC 7875

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Dimensions of Galvanised Double Steel Tape Armour are available upon request. 4.) Other jacket materials are available upon request. 5.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 21: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 20Industrial Cables

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

7. Armour: Galvanised Round Steel Wires.8. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Black).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-J-XFOSSWYu XLPE18 2 0.66 1.27 0.9 1.27 17.26

41202PC2-J-YaOSSWYu PVC 44004PC2-J-XFOSSWYu XLPE

18 4 0.66 1.27 1.25 1.27 19.68601

04PC2-J-YaOSSWYu PVC 64006PC2-J-XFOSSWYu XLPE

18 6 0.66 1.52 1.25 1.27 22.59755

06PC2-J-YaOSSWYu PVC 78508PC2-J-XFOSSWYu XLPE

18 8 0.66 1.52 1.60 1.27 25.141017

08PC2-J-YaOSSWYu PVC 107510PC2-J-XFOSSWYu XLPE

18 10 0.66 1.52 1.60 1.27 27.391179

10PC2-J-YaOSSWYu PVC 125512PC2-J-XFOSSWYu XLPE

18 12 0.66 1.52 1.60 1.27 28.051252

12PC2-J-YaOSSWYu PVC 133016PC2-J-XFOSSWYu XLPE

18 16 0.66 1.78 2.0 1.27 31.611681

16PC2-J-YaOSSWYu PVC 178024PC2-J-XFOSSWYu XLPE

18 24 0.66 1.78 2.0 1.27 36.942180

24PC2-J-YaOSSWYu PVC 230036PC2-J-XFOSSWYu XLPE

18 36 0.66 2.03 2.50 1.52 43.093122

36PC2-J-YaOSSWYu PVC 332502PC2-H-XFOSSWYu XLPE

16 2 0.66 1.27 0.90 1.27 18.24460

02PC2-H-YaOSSWYu PVC 48504PC2-H-XFOSSWYu XLPE

16 4 0.66 1.27 1.25 1.27 20.87688

04PC2-H-YaOSSWYu PVC 72506PC2-H-XFOSSWYu XLPE

16 6 0.66 1.52 1.60 1.27 24.771024

06PC2-H-YaOSSWYu PVC 106008PC2-H-XFOSSWYu XLPE

16 8 0.66 1.52 1.60 1.27 26.831187

08PC2-H-YaOSSWYu PVC 123510PC2-H-XFOSSWYu XLPE

16 10 0.66 1.52 1.60 1.27 29.361373

10PC2-H-YaOSSWYu PVC 143512PC2-H-XFOSSWYu XLPE

16 12 0.66 1.78 2.0 1.27 31.441704

12PC2-H-YaOSSWYu PVC 179516PC2-H-XFOSSWYu XLPE

16 16 0.66 1.78 2.0 1.27 33.921982

16PC2-H-YaOSSWYu PVC 209524PC2-H-XFOSSWYu XLPE

16 24 0.66 2.03 2.50 1.27 41.412900

24PC2-H-YaOSSWYu PVC 304036PC2-H-XFOSSWYu XLPE

16 36 0.66 2.03 2.50 1.52 46.533749

36PC2-H-YaOSSWYu PVC 3945

12368 5 47

MULTI PAIR/TRIAD, XLPE/PVC, UNSHIELDED WITH OVERALL SHIELD, STEEL WIRE ARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 22: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 21 Industrial Cables

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

MULTI TRIAD XLPE/PVC UNSHIELDED WITH OVERALL SHIELD– WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-I-XFOSSWYu XLPE14 2 0.66 1.27 1.25 1.27 20.19

62302PC2-I-YaOSSWYu PVC 65504PC2-I-XFOSSWYu XLPE

14 4 0.66 1.52 1.25 1.27 22.91847

04PC2-I-YaOSSWYu PVC 89506PC2-I-XFOSSWYu XLPE

14 6 0.66 1.52 1.60 1.27 26.641197

06PC2-I-YaOSSWYu PVC 126008PC2-I-XFOSSWYu XLPE

14 8 0.66 1.52 1.60 1.27 28.981413

08PC2-I-YaOSSWYu PVC 149010PC2-I-XFOSSWYu XLPE

14 10 0.66 1.78 2.0 1.27 33.201900

10PC2-I-YaOSSWYu PVC 199012PC2-I-XFOSSWYu XLPE

14 12 0.66 1.78 2.0 1.27 34.042040

12PC2-I-YaOSSWYu PVC 215016PC2-I-XFOSSWYu XLPE

14 16 0.66 1.78 2.0 1.27 36.852414

16PC2-I-YaOSSWYu PVC 252024PC2-I-XFOSSWYu XLPE

14 24 0.66 2.03 2.50 1.52 45.683668

24PC2-I-YaOSSWYu PVC 382536PC2-I-XFOSSWYu XLPE

14 36 0.66 2.29 2.50 1.52 51.444713

36PC2-I-YaOSSWYu PVC 488002PC2-G-XFOSSWYu XLPE

12 2 0.66 1.27 1.25 1.27 21.73731

02PC2-G-YaOSSWYu PVC 77504PC2-G-XFOSSWYu XLPE

12 4 0.66 1.52 1.60 1.27 25.481145

04PC2-G-YaOSSWYu PVC 119506PC2-G-XFOSSWYu XLPE

12 6 0.66 1.52 1.60 1.27 28.951459

06PC2-G-YaOSSWYu PVC 153008PC2-G-XFOSSWYu XLPE

12 8 0.66 1.78 2.0 1.27 31.991967

08PC2-G-YaOSSWYu PVC 205510PC2-G-XFOSSWYu XLPE

12 10 0.66 1.78 2.0 1.27 33.102320

10PC2-G-YaOSSWYu PVC 240012PC2-G-XFOSSWYu XLPE

12 12 0.66 1.78 2.0 1.27 37.242512

12PC2-G-YaOSSWYu PVC 263516PC2-G-XFOSSWYu XLPE

12 16 0.66 2.03 2.50 1.27 42.003390

16PC2-G-YaOSSWYu PVC 354524PC2-G-XFOSSWYu XLPE

12 24 0.66 2.03 2.50 1.52 46.604579

24PC2-G-YaOSSWYu PVC 476536PC2-G-XFOSSWYu XLPE

12 36 0.66 2.29 2.50 1.52 53.105979

36PC2-G-YaOSSWYu PVC 6260

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XFOSSWYu XLPE18 2 0.66 1.27 0.90 1.27 18.46

47202TC2-J-YaOSSWYu PVC 50004TC2-J-XFOSSWYu XLPE

18 4 0.66 1.27 1.25 1.27 21.13709

04TC2-J-YaOSSWYu PVC 75506TC2-J-XFOSSWYu XLPE

18 6 0.66 1.52 1.60 1.27 25.081040

06TC2-J-YaOSSWYu PVC 110008TC2-J-XFOSSWYu XLPE

18 8 0.66 1.52 1.60 1.27 27.201208

08TC2-J-YaOSSWYu PVC 128510TC2-J-XFOSSWYu XLPE

18 10 0.66 1.78 2.0 1.27 31.131470

10TC2-J-YaOSSWYu PVC 154512TC2-J-XFOSSWYu XLPE

18 12 0.66 1.78 2.0 1.27 31.901770

12TC2-J-YaOSSWYu PVC 186516TC2-J-XFOSSWYu XLPE

18 16 0.66 1.78 2.0 1.27 34.422046

16TC2-J-YaOSSWYu PVC 215524TC2-J-XFOSSWYu XLPE

18 24 0.66 2.03 2.50 1.27 38.903061

24TC2-J-YaOSSWYu PVC 325536TC2-J-XFOSSWYu XLPE

18 36 0.66 2.03 2.50 1.52 47.283872

36TC2-J-YaOSSWYu PVC 4120

Page 23: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 22Industrial Cables

MULTI TRIAD XLPE/PVC UNSHIELDED WITH OVERALL SHIELD– WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-H-XFOSSWYu XLPE16 2 0.66 1.27 1.25 1.27 17.10

63502TC2-H-YaOSSWYu PVC 67004TC2-H-XFOSSWYu XLPE

16 4 0.66 1.52 1.25 1.27 23.03863

04TC2-H-YaOSSWYu PVC 90506TC2-H-XFOSSWYu XLPE

16 6 0.66 1.52 1.60 1.27 26.781221

06TC2-H-YaOSSWYu PVC 127808TC2-H-XFOSSWYu XLPE

16 8 0.66 1.52 1.60 1.27 29.151424

08TC2-H-YaOSSWYu PVC 151510TC2-H-XFOSSWYu XLPE

16 10 0.66 1.78 2.0 1.27 33.291914

10TC2-H-YaOSSWYu PVC 202012TC2-H-XFOSSWYu XLPE

16 12 0.66 1.78 2.0 1.27 34.242057

12TC2-H-YaOSSWYu PVC 218016TC2-H-XFOSSWYu XLPE

16 16 0.66 1.78 2.0 1.27 37.082435

16TC2-H-YaOSSWYu PVC 259024TC2-H-XFOSSWYu XLPE

16 24 0.66 2.03 2.50 1.52 45.973700

24TC2-H-YaOSSWYu PVC 393036TC2-H-XFOSSWYu XLPE

16 36 0.66 2.29 2.50 1.52 51.774759

36TC2-H-YaOSSWYu PVC 509002TC2-I-XFOSSWYu XLPE

14 2 0.66 1.27 1.25 1.27 21.71732

02TC2-I-YaOSSWYu PVC 77504TC2-I-XFOSSWYu XLPE

14 4 0.66 1.52 1.60 1.27 25.451148

04TC2-I-YaOSSWYu PVC 121006TC2-I-XFOSSWYu XLPE

14 6 0.66 1.52 1.60 1.27 28.921463

06TC2-I-YaOSSWYu PVC 154508TC2-I-XFOSSWYu XLPE

14 8 0.66 1.78 2.0 1.27 32.961973

08TC2-I-YaOSSWYu PVC 207510TC2-I-XFOSSWYu XLPE

14 10 0.66 1.78 2.0 1.27 36.252328

10TC2-I-YaOSSWYu PVC 242512TC2-I-XFOSSWYu XLPE

14 12 0.66 1.78 2.0 1.27 37.202521

12TC2-I-YaOSSWYu PVC 266516TC2-I-XFOSSWYu XLPE

14 16 0.66 2.03 2.50 1.27 41.953403

16TC2-I-YaOSSWYu PVC 354524TC2-I-XFOSSWYu XLPE

14 24 0.66 2.03 2.50 1.52 50.254559

24TC2-I-YaOSSWYu PVC 483036TC2-I-XFOSSWYu XLPE

14 36 0.66 2.29 2.50 1.52 56.776009

36TC2-I-YaOSSWYu PVC 635002TC2-G-XFOSSWYu XLPE

12 2 0.66 1.52 1.60 1.27 24.701041

02TC2-G-YaOSSWYu PVC 107504TC2-G-XFOSSWYu XLPE

12 4 0.66 1.52 1.60 1.27 27.581391

04TC2-G-YaOSSWYu PVC 146006TC2-G-XFOSSWYu XLPE

12 6 0.66 1.78 2.0 1.27 32.912041

06TC2-G-YaOSSWYu PVC 213508TC2-G-XFOSSWYu XLPE

12 8 0.66 1.78 2.0 1.27 35.992442

08TC2-G-YaOSSWYu PVC 256510TC2-G-XFOSSWYu XLPE

12 10 0.66 1.78 2.50 1.27 40.763177

10TC2-G-YaOSSWYu PVC 332012TC2-G-XFOSSWYu XLPE

12 12 0.66 2.03 2.50 1.52 42.913599

12TC2-G-YaOSSWYu PVC 371516TC2-G-XFOSSWYu XLPE

12 16 0.66 2.03 2.50 1.52 46.614315

16TC2-G-YaOSSWYu PVC 454024TC2-G-XFOSSWYu XLPE

12 24 0.66 2.29 2.50 1.52 56.065925

24TC2-G-YaOSSWYu PVC 624536TC2-G-XFOSSWYu XLPE

12 36 0.66 2.55 2.50 1.90 64.277972

36TC2-G-YaOSSWYu PVC 8445

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/Triad counts are available upon request. 3.) Dimensions of cables with Galvanised Double Steel Tape Armour are available upon request. 4.) Other jacket materials are available upon request. 5.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 24: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 23 Industrial Cables

1. Conductor: Stranded Plain/Tinned Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.4. Individual Screening/Shield: Aluminium-

Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

8. Armour: Galvanised Round Steel Wires.9. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Black).

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-J-XFISSWYu XLPE18 2 0.66 1.27 0.90 1.27 17.85

44502PC2-J-YaISSWYu PVC 46504PC2-J-XFISSWYu XLPE

18 4 0.66 1.27 1.25 1.27 20.39660

04PC2-J-YaISSWYu PVC 69506PC2-J-XFISSWYu XLPE

18 6 0.66 1.52 1.25 1.27 23.47863

06PC2-J-YaISSWYu PVC 89508PC2-J-XFISSWYu XLPE

18 8 0.66 1.52 1.60 1.27 26.151124

08PC2-J-YaISSWYu PVC 118010PC2-J-XFISSWYu XLPE

18 10 0.66 1.52 1.60 1.27 28.571303

10PC2-J-YaISSWYu PVC 137012PC2-J-XFISSWYu XLPE

18 12 0.66 1.52 1.60 1.27 29.271409

12PC2-J-YaISSWYu PVC 147016PC2-J-XFISSWYu XLPE

18 16 0.66 1.78 2.0 1.27 32.091874

16PC2-J-YaISSWYu PVC 197024PC2-J-XFISSWYu XLPE

18 24 0.66 1.78 2.50 1.27 39.702755

24PC2-J-YaISSWYu PVC 258036PC2-J-XFISSWYu XLPE

18 36 0.66 2.03 2.50 1.52 45.153549

36PC2-J-YaISSWYu PVC 3840

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

12349 6 578

MULTI PAIR/TRIAD, XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD, STEEL WIRE ARMOURED INSTRUMENTATION CABLE

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 25: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 24Industrial Cables

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-H-XFISSWYu XLPE16 2 0.66 1.27 1.25 1.27 19.56

58002PC2-H-YaISSWYu PVC 62004PC2-H-XFISSWYu XLPE

16 4 0.66 1.27 1.25 1.27 21.61747

04PC2-H-YaISSWYu PVC 80006PC2-H-XFISSWYu XLPE

16 6 0.66 1.52 1.60 1.27 25.681099

06PC2-H-YaISSWYu PVC 117008PC2-H-XFISSWYu XLPE

16 8 0.66 1.52 1.60 1.27 27.891295

08PC2-H-YaISSWYu PVC 138510PC2-H-XFISSWYu XLPE

16 10 0.66 1.78 1.60 1.27 31.931743

10PC2-H-YaISSWYu PVC 185512PC2-H-XFISSWYu XLPE

16 12 0.66 1.78 2.0 1.27 32.721865

12PC2-H-YaISSWYu PVC 199516PC2-H-XFISSWYu XLPE

16 16 0.66 1.78 2.0 1.27 35.362176

16PC2-H-YaISSWYu PVC 234024PC2-H-XFISSWYu XLPE

16 24 0.66 2.03 2.0 1.52 43.783308

24PC2-H-YaISSWYu PVC 355536PC2-H-XFISSWYu XLPE

16 36 0.66 2.03 2.50 1.52 48.684140

36PC2-H-YaISSWYu PVC 449002PC2-I-XFISSWYu XLPE

14 2 0.66 1.27 1.25 1.27 20.83687

02PC2-I-YaISSWYu PVC 70504PC2-I-XFISSWYu XLPE

14 4 0.66 1.52 1.25 1.27 23.69911

04PC2-I-YaISSWYu PVC 97006PC2-I-XFISSWYu XLPE

14 6 0.66 1.52 1.60 1.27 24.401292

06PC2-I-YaISSWYu PVC 137508PC2-I-XFISSWYu XLPE

14 8 0.66 1.78 2.0 1.27 31.401760

08PC2-I-YaISSWYu PVC 186510PC2-I-XFISSWYu XLPE

14 10 0.66 1.78 2.0 1.27 34.492052

10PC2-I-YaISSWYu PVC 217512PC2-I-XFISSWYu XLPE

14 12 0.66 1.78 2.0 1.27 35.372209

12PC2-I-YaISSWYu PVC 235016PC2-I-XFISSWYu XLPE

14 16 0.66 1.78 2.0 1.27 38.362619

16PC2-I-YaISSWYu PVC 280024PC2-I-XFISSWYu XLPE

14 24 0.66 2.03 2.50 1.52 47.613979

24PC2-I-YaISSWYu PVC 425036PC2-I-XFISSWYu XLPE

14 36 0.66 2.29 2.50 1.52 53.695169

36PC2-I-YaISSWYu PVC 552002PC2-G-XFISSWYu XLPE

12 2 0.66 1.52 1.25 1.27 22.94811

02PC2-G-YaISSWYu PVC 85004PC2-G-XFISSWYu XLPE

12 4 0.66 1.52 1.60 1.27 26.301221

04PC2-G-YaISSWYu PVC 128506PC2-G-XFISSWYu XLPE

12 6 0.66 1.78 2.0 1.27 31.321788

06PC2-G-YaISSWYu PVC 188008PC2-G-XFISSWYu XLPE

12 8 0.66 1.78 2.0 1.27 34.162101

08PC2-G-YaISSWYu PVC 221510PC2-G-XFISSWYu XLPE

12 10 0.66 1.78 2.0 1.27 37.642473

10PC2-G-YaISSWYu PVC 261012PC2-G-XFISSWYu XLPE

12 12 0.66 1.78 2.0 1.27 38.662683

12PC2-G-YaISSWYu PVC 284016PC2-G-XFISSWYu XLPE

12 16 0.66 2.03 2.50 1.52 40.403678

16PC2-G-YaISSWYu PVC 389524PC2-G-XFISSWYu XLPE

12 24 0.66 2.29 2.50 1.52 49.204996

24PC2-G-YaISSWYu PVC 530036PC2-G-XFISSWYu XLPE

12 36 0.66 2.29 2.50 1.52 59.216438

36PC2-G-YaISSWYu PVC 6840

Page 26: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 25 Industrial Cables

MULTI TRIAD XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/Triad counts are available upon request. 3.) Dimensions of cables with Galvanised Double Steel Tape Armour are available upon request. 4.) Other jacket materials are available upon request. 5.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XFISSWYu XLPE18 2 0.66 1.27 1.25 1.27 20.35

62002TC2-J-YaISSWYu PVC 65004TC2-J-XFISSWYu XLPE

18 4 0.66 1.52 1.25 1.27 23.10832

04TC2-J-YaISSWYu PVC 87506TC2-J-XFISSWYu XLPE

18 6 0.66 1.52 1.60 1.27 26.871176

06TC2-J-YaISSWYu PVC 123508TC2-J-XFISSWYu XLPE

18 8 0.66 1.52 1.60 1.27 29.251363

08TC2-J-YaISSWYu PVC 144010TC2-J-XFISSWYu XLPE

18 10 0.66 1.78 2.0 1.27 33.511838

10TC2-J-YaISSWYu PVC 193012TC2-J-XFISSWYu XLPE

18 12 0.66 1.78 2.0 1.27 34.361989

12TC2-J-YaISSWYu PVC 207016TC2-J-XFISSWYu XLPE

18 16 0.66 1.78 2.0 1.27 37.222312

16TC2-J-YaISSWYu PVC 244524TC2-J-XFISSWYu XLPE

18 24 0.66 2.03 2.50 1.52 46.153575

24TC2-J-YaISSWYu PVC 372036TC2-J-XFISSWYu XLPE

18 36 0.66 2.29 2.50 1.52 51.984519

36TC2-J-YaISSWYu PVC 477002TC2-H-XFISSWYu XLPE

16 2 0.66 1.27 1.25 1.27 21.57698

02TC2-H-YaISSWYu PVC 74004TC2-H-XFISSWYu XLPE

16 4 0.66 1.52 1.60 1.27 25.281080

04TC2-H-YaISSWYu PVC 112506TC2-H-XFISSWYu XLPE

16 6 0.66 1.52 1.60 1.27 28.701347

06TC2-H-YaISSWYu PVC 143508TC2-H-XFISSWYu XLPE

16 8 0.66 1.78 2.0 1.27 32.711839

08TC2-H-YaISSWYu PVC 195010TC2-H-XFISSWYu XLPE

16 10 0.66 1.78 2.0 1.27 35.962137

10TC2-H-YaISSWYu PVC 227012TC2-H-XFISSWYu XLPE

16 12 0.66 1.78 2.0 1.27 36.902322

12TC2-H-YaISSWYu PVC 245016TC2-H-XFISSWYu XLPE

16 16 0.66 2.03 2.50 1.27 41.613100

16TC2-H-YaISSWYu PVC 330024TC2-H-XFISSWYu XLPE

16 24 0.66 2.03 2.50 1.52 49.814162

24TC2-H-YaISSWYu PVC 446036TC2-H-XFISSWYu XLPE

16 36 0.66 2.29 2.50 1.52 56.265377

36TC2-H-YaISSWYu PVC 580502TC2-I-XFOISWYu XLPE

14 2 0.66 1.52 1.25 1.27 23.64843

02TC2-I-YaISSWYu PVC 89004TC2-I-XFISSWYu XLPE

14 4 0.66 1.52 1.60 1.27 27.141253

04TC2-I-YaISSWYu PVC 132506TC2-I-XFISSWYu XLPE

14 6 0.66 1.78 2.0 1.27 32.361835

06TC2-I-YaISSWYu PVC 194008TC2-I-XFISSWYu XLPE

14 8 0.66 1.78 2.0 1.27 35.382177

08TC2-I-YaISSWYu PVC 230010TC2-I-XFISSWYu XLPE

14 10 0.66 1.78 2.50 1.27 40.042839

10TC2-I-YaISSWYu PVC 271012TC2-I-XFISSWYu XLPE

14 12 0.66 2.03 2.50 1.27 41.633152

12TC2-I-YaISSWYu PVC 333516TC2-I-XFISSWYu XLPE

14 16 0.66 2.03 2.50 1.52 45.673801

16TC2-I-YaISSWYu PVC 403524TC2-I-XFISSWYu XLPE

14 24 0.66 2.29 2.50 1.52 46.305135

24TC2-I-YaISSWYu PVC 548036TC2-I-XFISSWYu XLPE

14 36 0.66 2.55 2.50 1.90 63.006830

36TC2-I-YaISSWYu PVC 735002TC2-G-XFISSWYu XLPE

12 2 0.66 1.52 1.60 1.27 26.241129

02TC2-G-YaISSWYu PVC 116004TC2-G-XFISSWYu XLPE

12 4 0.66 1.52 1.60 1.27 29.441526

04TC2-G-YaISSWYu PVC 160006TC2-G-XFISSWYu XLPE

12 6 0.66 1.78 2.0 1.27 35.212230

06TC2-G-YaISSWYu PVC 234008TC2-G-XFISSWYu XLPE

12 8 0.66 1.78 2.0 1.27 38.642654

08TC2-G-YaISSWYu PVC 280010TC2-G-XFISSWYu XLPE

12 10 0.66 2.03 2.50 1.52 44.893614

10TC2-G-YaISSWYu PVC 380012TC2-G-XFISSWYu XLPE

12 12 0.66 2.03 2.50 1.52 46.113920

12TC2-G-YaISSWYu PVC 412016TC2-G-XFISSWYu XLPE

12 16 0.66 2.03 2.50 1.52 50.224679

16TC2-G-YaISSWYu PVC 495024TC2-G-XFISSWYu XLPE

12 24 0.66 2.55 2.50 1.52 61.236540

24TC2-G-YaISSWYu PVC 692036TC2-G-XFISSWYu XLPE

12 36 0.66 2.55 2.50 1.52 69.958656

36PC2-G-YaISSWYu PVC 9220

Page 27: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 26Industrial Cables

APPLICATION

• The cables are recommended for indoor and outdoor installation in dry and wet locations, in cable racks and trays, in conduits and suitable for direct burial.

• For Transmission of analogue and digital signals in instrument and control systems; allowed for use in hazardous classified locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources, e.g. public mains electricity supply.

• For industrial automation process that applies a basic or advanced control system.

ELECTRICAL PROPERTIES OF 300V FOUNDATION FIELDBUS

Conductor size (AWG) 18

Max. Conductor Resistance @ 20°C Ω / km ≤ 24.0

Max. Mutual Capacitance (between conductors) nF/Km ≤ 115

Max. attenuation at 1.25 fr (39 kHz) dB/Km ≤ 3.0

Max. Propagation delay change 0.25 fr to 1.25 fr µs/Km ≤ 1.7

Max. Capacitance unbalance (wire to shield) nF/Km ≤ 4

Zo at fr (31.25 kHz) Ω 100 Ω ± 20 %

Insulation Resistance in water @ 15.6°C MΩ – Km ≥ 700

Dielectric Voltage Withstand Test 1500 VAC for 1 Minute

PHYSICAL PROPERTIES

Flame Retardancy Passes UL 1685 vertical tray flame test & IEC 60332-3 Cat.A or C

Sunlight Resistance Passes UL-1581 test (720 hours)

Oil Resistance Passes UL-13 test (Oil I)

Minimum Bending Radius7.5 x Cable Outside Diameter (for unarmoured cables)10 x Cable Outside Diameter (for armoured cables)

Temperature Range (operation)During Operation: -30°C to +90°CDuring Installation: -5°C to +50°C

INSULATION AND JACKET COLOURS

Pair colour Black & White. Other pair colours are available upon request.

Jacket colour Orange. Other colours are available upon request.

Single & Multipair and Multi-Triple, individual and /or Collective screen, PVC- sheath

Cable Features:UnarmouredArmoured

Common Cable Construction:Conductor Type– Stranded Tinned Copper

Insulation Material– XLPE 90°C– PVC 90°C

Unarmoured

Armoured– Galvanised Steel Wires– Double Steel Tape

Jackets– PVC Flame Retardant, Oil and Sunlight Resistant– Low Smoke Zero Halogen Free

FOUNDATION FIELDBUS CABLE TO IEC 61158-2 TYPE A.UL 13 / UL 2250, PLTC / ITC, 90°C / 300VFOUNDATION FIELDBUS CABLE TO IEC 61158-2 TYPE A

Page 28: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 27 Industrial Cables

SINGLE PAIR XLPE SHIELDED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Stranded Tinned Copper conductor.

2. Insulation: XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with filler and polyester wrapping tape.

4. Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Orange).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SCCItem Code

Insulation Material Type

Conductor size (AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net WeightApprox. (kg/

km)01PT2-J-XFOSYu XLPE 18 0.65 1.02 8.80 58

12345

SINGLE PAIR, XLPE, SHIELDED, UNARMOURED, FOUNDATION FIELDBUS CABLE

UL 13 / UL 2250, PLTC/ITC, 90°C / 300VFOUNDATION FIELDBUS CABLE TO IEC 61158-2 TYPE A

Page 29: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 28Industrial Cables

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

1. Conductor: Stranded Tinned Copper conductor.

2. Insulation: XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with filler and polyester wrapping tape.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Orange).

MULTI PAIR XLPE WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XFISYu XLPE 18 2 0.65 1.27 13.40 13604TC2-J-XFISYu XLPE 18 4 0.65 1.27 15.20 21206TC2-J-XFISYu XLPE 18 6 0.65 1.27 18.30 31208TC2-J-XFISYu XLPE 18 8 0.65 1.27 20.25 39110TC2-J-XFISYu XLPE 18 10 0.65 1.27 22.70 47312TC2-J-XFISYu XLPE 18 12 0.65 1.27 23.40 54316TC2-J-XFISYu XLPE 18 16 0.65 1.78 26.30 71924TC2-J-XFISYu XLPE 18 24 0.65 1.78 32.00 102636TC2-J-XFISYu XLPE 18 36 0.65 2.03 36.95 1491

12347 56

MULTI PAIR, XLPE WITH INDIVIDUAL AND OVERALL SHIELD, UNARMOURED, FOUNDATION FIELDBUS CABLE

UL 13 / UL 2250, PLTC/ITC, 90°C / 300VFOUNDATION FIELDBUS CABLE TO IEC 61158-2 TYPE A

Page 30: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 29 Industrial Cables

SINGLE PAIR XLPE SHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Stranded Tinned Copper conductor.

2. Insulation: XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with filler and polyester wrapping tape.

4. Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

6. Armour: Galvanised Round Steel Wires.7. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Orange).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PT2-J-XFOSSWYu XLPE 18 0.65 1.02 0.90 1.02 13.00 250

12347 56

SINGLE PAIR, XLPE, SHIELDED, STEEL WIRE ARMOURED, FOUNDATION FIELDBUS CABLE

UL 13 / UL 2250, PLTC/ITC, 90°C / 300VFOUNDATION FIELDBUS CABLE TO IEC 61158-2 TYPE A

Page 31: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 30Industrial Cables

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

1. Conductor: Stranded Tinned Copper conductor.

2. Insulation: XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with filler and polyester wrapping tape.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

8. Armour: Galvanised Round Steel Wires.9. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Orange).

MULTI PAIR XLPE WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-J-XFISWFYu XLPE 18 2 0.65 1.27 0.90 1.27 17.85 44504TC2-J-XFISSWYu XLPE 18 4 0.65 1.27 1.25 1.27 20.40 66006TC2-J-XFISSWYu XLPE 18 6 0.65 1.52 1.25 1.27 23.45 86308TC2-J-XFISSWYu XLPE 18 8 0.65 1.52 1.60 1.27 26.15 112410TC2-J-XFISSWYu XLPE 18 10 0.65 1.52 1.60 1.27 28.55 130312TC2-J-XFISSWYu XLPE 18 12 0.65 1.52 1.60 1.27 29.25 140916TC2-J-XFISSWYu XLPE 18 16 0.65 1.78 2.00 1.27 33.00 187424TC2-J-XFISSWYu XLPE 18 24 0.65 1.78 2.50 1.27 39.70 275536TC2-J-XFISSWYu XLPE 18 36 0.65 2.03 2.50 1.52 45.15 2549

12349 5678

MULTI PAIR, XLPE WITH INDIVIDUAL AND OVERALL SHIELD, STEEL WIRE ARMOURED, FOUNDATION FIELDBUS CABLE

UL 13 / UL 2250, PLTC/ITC, 90°C / 300VFOUNDATION FIELDBUS CABLE TO IEC 61158-2 TYPE A

Page 32: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 31 Industrial Cables

A P P L I C A T I O N

• The cables are recommended for indoor and outdoor installation in dry and wet locations, in cable racks and trays, in conduits and suitable for direct burial.

• For the transmission of thermoelectric voltage from measuring junction to reference junction; allowed for use in zone 1 and zone 2, group II, classified areas (IEC 79-14).

Single & Multipair and Multi-Triple, individual and /or Collective screen, PVC- sheath

TABLE 1: TYPES AND COLOUR CODES OF THERMOCOUPLE CABLES

THERMOCOUPLE IEC 60584 ANSI MC 96.1

TYPEMATERIAL INSULATION AND JACKET COLOUR INSULATION AND JACKET COLOUR

Positive Leg (+)

Negative Leg (-)

Positive Leg (+)

Negative Leg (-) Jacket Positive

Leg (+)Negative

Leg (-) Jacket

KNickel-

ChromiumNickel-

AluminiumGreen White Green Yellow Red Yellow

ENickel-

ChromiumCopper Nickel

Purple White Purple Purple Red Purple

J IronCopper Nickel

Black White Black White Red Black

T CopperCopper Nickel

Brown White Brown Blue Red Blue

NNickel-

Chromium Silicon

Nickel-Silicon Pink White Pink Orange Red Orange

THERMOCOUPLE TEMPERATURE RANGE

Types* Temperature Range

K -20°C to 200°C

E -20°C to 200°C

J -20°C to 200°C

T -59°C to 68°C

N -20°C to 200°C

PHYSICAL PROPERTIES

Flame Retardancy Passes UL 1685 vertical tray flame test & IEC 60332-3 Cat. A or C

Sunlight Resistance Passes UL-1581 test (720 hours)

Oil Resistance Passes UL-13 test (Oil I)

Minimum Bending Radius7.5 x Cable Outside Diameter (for unarmoured cables) 10 x Cable Outside Diameter (for armoured cables)

Temperature Range (operation)During Operation: -30°C to +90°C During Installation: -5°C to +50°C

Cable Features:UnarmouredArmoured

Common Cable Construction:Conductor Type– Thermocouple Extension, (Table 1)

Insulation Material– XLPE 90°C– PVC 90°C

Unarmoured

Armoured– Galvanised Steel Wires– Double Steel Tape

Jackets– PVC Flame Retardant, Oil and Sunlight Resistant– Low Smoke Zero Halogen Free

* Other types are available upon request.

THERMOCOUPLE CABLES TO ANSI MC 96.1 AND IEC 60584

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 33: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 32Industrial Cables

SINGLE PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.

3. Pairing/Triads: Uniformly twisted insulated conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Yellow).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard cutting length 1000m ± 5%, other lengths are available upon request.

SCCItem Code

Insulation Material Type

Conductor size (AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/

km)01PKX-J-XFYu XLPE

18 0.40 0.89 7.3039

01PKX-J-YaYu PVC 4101PKX-H-XFYu XLPE

16 0.40 0.89 7.8551

01PKX-H-YaYu PVC 5401PKX-I-XFYu XLPE

14 0.40 1.02 9.3269

01PKX-I-YaYu PVC 7201PKX-G-XFYu XLPE

12 0.40 1.02 10.16100

01PKX-G-YaYu PVC 103

1234

SINGLE PAIR, XLPE/PVC, UNSHIELDED, UNARMOURED, THERMOCOUPLE CABLES

UL 13/UL 2250, PLTC/ITC, 90°C/300VTHERMOCOUPLE CABLES

Page 34: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 33 Industrial Cables

SINGLE PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted

insulated conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Screening/Shielding: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Yellow).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard cutting length 1000m ± 5%, other lengths are available upon request.

SCCItem Code

Insulation Material Type

Conductor size (AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/

km)01PKX-J-XFOSYu XLPE

18 0.40 0.89 7.4445

01PKX-J-YaOSYu PVC 4701PKX-H-XFOSYu XLPE

16 0.40 0.89 7.9858

01PKX-H-YaOSYu PVC 6001PKX-I-XFOSYu XLPE

14 0.40 1.02 9.4585

01PKX-I-YaOSYu PVC 8901PKX-G-XFOSYu XLPE

12 0.40 1.02 10.29112

01PKX-G-YaOSYu PVC 116

12345

SINGLE PAIR, XLPE/PVC, SHIELDED, UNARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 35: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 34Industrial Cables

MULTI PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Yellow).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-J-XFYu XLPE18 2 0.40 1.02 9.68 71

02PKX-J-YaYu PVC 7504PKX-J-XFYu XLPE

18 4 0.40 1.02 10.93 11304PKX-J-YaYu PVC 12106PKX-J-XFYu XLPE

18 6 0.40 1.27 13.19 17206PKX-J-YaYu PVC 18308PKX-J-XFYu XLPE

18 8 0.40 1.27 14.54 21608PKX-J-YaYu PVC 23110PKX-J-XFYu XLPE

18 10 0.40 1.27 16.18 26210PKX-J-YaYu PVC 28112PKX-J-XFYu XLPE

18 12 0.40 1.27 16.66 30112PKX-J-YaYu PVC 32316PKX-J-XFYu XLPE

18 16 0.40 1.52 18.79 40316PKX-J-YaYu PVC 43324PKX-J-XFYu XLPE

18 24 0.40 1.52 22.67 57524PKX-J-YaYu PVC 62036PKX-J-XFYu XLPE

18 36 0.40 1.78 26.20 84336PKX-J-YaYu PVC 910

12345

MULTI PAIR, XLPE/PVC, UNSHIELDED, UNARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 36: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 35 Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-H-XFYu XLPE16 2 0.40 1.02 10.57

9602PKX-H-YaYu PVC 10004PKX-H-XFYu XLPE

16 4 0.40 1.27 12.53171

04PKX-H-YaYu PVC 18006PKX-H-XFYu XLPE

16 6 0.40 1.27 14.52240

06PKX-H-YaYu PVC 25308PKX-H-XFYu XLPE

16 8 0.40 1.27 16.07305

08PKX-H-YaYu PVC 32310PKX-H-XFYu XLPE

16 10 0.40 1.52 18.47392

10PKX-H-YaYu PVC 41412PKX-H-XFYu XLPE

16 12 0.40 1.52 19.02452

12PKX-H-YaYu PVC 47916PKX-H-XFYu XLPE

16 16 0.40 1.52 20.87577

16PKX-H-YaYu PVC 61324PKX-H-XFYu XLPE

16 24 0.40 1.78 25.88863

24PKX-H-YaYu PVC 91636PC2-H-XFYu XLPE

16 36 0.40 1.78 29.301227

36PKX-H-YaYu PVC 130702PKX-I-XFYu XLPE

14 2 0.40 1.27 13.06153

02PKX-I-YaYu PVC 16104PKX-I-XFYu XLPE

14 4 0.40 1.27 14.92255

04PKX-I-YaYu PVC 27006PKX-I-XFYu XLPE

14 6 0.40 1.52 17.99380

06PKX-I-YaYu PVC 40208PKX-I-XFYu XLPE

14 8 0.40 1.52 19.98484

08PKX-I-YaYu PVC 51410PKX-I-XFYu XLPE

14 10 0.40 1.52 22.41592

10PKX-I-YaYu PVC 63012PKX-I-XFYu XLPE

14 12 0.40 1.52 23.11687

12PKX-I-YaYu PVC 73216PKX-I-XFYu XLPE

14 16 0.40 1.78 26.04915

16PKX-I-YaYu PVC 97524PKX-I-XFYu XLPE

14 24 0.40 1.78 31.781324

24PKX-I-YaYu PVC 141536PKX-I-XFYu XLPE

14 36 0.40 2.03 36.711944

36PKX-I-YaYu PVC 207902PKX-G-XFYu XLPE

12 2 0.40 1.27 14.44208

02PKX-G-YaYu PVC 21704PKX-G-XFYu XLPE

12 4 0.40 1.27 16.58356

04PKX-G-YaYu PVC 37406PKX-G-XFYu XLPE

12 6 0.40 1.52 20.06533

06PKX-G-YaYu PVC 55908PKX-G-XFYu XLPE

12 8 0.40 1.52 22.36685

08PKX-G-YaYu PVC 72110PC2-G-XFYu XLPE

12 10 0.40 1.78 25.71871

10PKX-G-YaYu PVC 91612PKX-G-XFYu XLPE

12 12 0.40 1.78 26.531014

12PKX-G-YaYu PVC 106816PKX-G-XFYu XLPE

12 16 0.40 1.78 29.281310

16PKX-G-YaYu PVC 138224PKX-G-XFYu XLPE 12 24 0.40 2.03 36.43 195124PKX-G-YaYu PVC 205936PKX-G-XFYu XLPE

12 36 0.40 2.03 41.532816

36PKX-G-YaYu PVC 2978

MULTI PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard cutting length 1000m ± 5%, other lengths are available upon request.

Page 37: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 36Industrial Cables

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Yellow).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-J-XFOSYu XLPE18 2 0.40 1.02 10.04

7902PKX-J-YaOSYu PVC 8304PKX-J-XFOSYu XLPE

18 4 0.40 1.27 11.82133

04PKX-J-YaOSYu PVC 14106PKX-J-XFOSYu XLPE

18 6 0.40 1.27 13.55181

06PKX-J-YaOSYu PVC 19208PKX-J-XFOSYu XLPE

18 8 0.40 1.52 14.90225

08PKX-J-YaOSYu PVC 24010PKX-J-XFOSYu XLPE

18 10 0.40 1.52 16.54272

10PKX-J-YaOSYu PVC 29012PKX-J-XFOSYu XLPE

18 12 0.40 1.52 17.54329

12PKX-J-YaOSYu PVC 35216PKX-J-XFOSYu XLPE

18 16 0.40 1.78 19.15414

16PKX-J-YaOSYu PVC 44424PC2-J-XFOSYu XLPE

18 24 0.40 1.78 23.03587

24PKX-J-YaOSYu PVC 63236PKX-J-XFOSYu XLPE

18 36 0.40 1.78 26.56856

36PKX-J-YaOSYu PVC 923

12345 6

MULTI PAIR, XLPE/PVC, UNSHIELDED WITH OVERALL SHIELD, UNARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLESUL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 38: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 37 Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-H-XFOSYu XLPE16 2 0.40 1.02 10.93

10402PKX-H-YaOSYu PVC 10804PKX-H-XFOSYu XLPE

16 4 0.40 1.27 12.89180

04PKX-H-YaOSYu PVC 18906PKX-H-XFOSYu XLPE

16 6 0.40 1.27 14.88249

06PKX-H-YaOSYu PVC 26208PKX-H-XFOSYu XLPE

16 8 0.40 1.27 16.43314

08PKX-H-YaOSYu PVC 33210PKX-H-XFOSYu XLPE

16 10 0.40 1.52 18.83403

10PKX-H-YaOSYu PVC 42512PKX-H-XFOSYu XLPE

16 12 0.40 1.52 19.38463

12PKX-H-YaOSYu PVC 48916PKX-H-XFOSYu XLPE

16 16 0.40 1.52 21.23588

16PKX-H-YaOSYu PVC 62424PKX-H-XFOSYu XLPE

16 24 0.40 1.78 26.24879

24PKX-H-YaOSYu PVC 92936PKX-H-XFOSYu XLPE

16 36 0.40 1.78 29.661241

36PKX-H-YaOSYu PVC 132102PKX-I-XFOSYu XLPE

14 2 0.40 1.27 13.42162

02PKX-I-YaOSYu PVC 17004PKX-I-XFOSYu XLPE

14 4 0.40 1.27 15.28264

04PKX-I-YaOSYu PVC 27906PKX-I-XFOSYu XLPE

14 6 0.40 1.52 18.35390

06PKX-I-YaOSYu PVC 41308PKX-I-XFOSYu XLPE

14 8 0.40 1.52 20.34495

08PKX-I-YaOSYu PVC 52510PKX-I-XFOSYu XLPE

14 10 0.40 1.52 22.77604

10PKX-I-YaOSYu PVC 64112PKX-I-XFOSYu XLPE

14 12 0.40 1.52 23.47699

12PKX-I-YaOSYu PVC 74416PKX-I-XFOSYu XLPE

14 16 0.40 1.78 26.40928

16PKX-I-YaOSYu PVC 98824PKX-I-XFOSYu XLPE

14 24 0.40 1.78 32.141338

24PKX-I-YaOSYu PVC 142936PKX-I-XFOSYu XLPE

14 36 0.40 2.03 37.071959

36PKX-I-YaOSYu PVC 209502PKX-G-XFOSYu XLPE

12 2 0.40 1.27 14.80217

02PKX-G-YaOSYu PVC 22604PKX-G-XFOSYu XLPE

12 4 0.40 1.52 17.46385

04PKX-G-YaOSYu PVC 40306PKX-G-XFOSYu XLPE

12 6 0.40 1.52 20.42543

06PKX-G-YaOSYu PVC 57008PKX-G-XFOSYu XLPE

12 8 0.40 1.52 22.72697

08PKX-G-YaOSYu PVC 73310PKX-G-XFOSYu XLPE

12 10 0.40 1.78 26.07884

10PKX-G-YaOSYu PVC 92912PKX-G-XFOSYu XLPE

12 12 0.40 1.78 26.891027

12PKX-G-YaOSYu PVC 108116PKX-G-XFOSYu XLPE

12 16 0.40 1.78 29.641323

16PKX-G-YaOSYu PVC 139524PKX-G-XFOSYu XLPE 12 24 0.40 2.03 36.79 196724PKX-G-YaOSYu PVC 207536PKX-G-XFOSYu XLPE

12 36 0.40 2.03 41.892833

36PKX-G-YaOSYu PVC 2995

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard cutting length 1000m ± 5%, other lengths are available upon request.

Page 39: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 38Industrial Cables

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Yellow).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-J-XFISYu XLPE18 2 0.40 1.02 10.70

9702PKX-J-YaISYu PVC 10104PKX-J-XFISYu XLPE

18 4 0.40 1.27 12.65168

04PKX-J-YaISYu PVC 17606PKX-J-XFISYu XLPE

18 6 0.40 1.27 14.56230

06PKX-J-YaISYu PVC 24208PKX-J-XFISYu XLPE

18 8 0.40 1.52 16.05290

08PKX-J-YaISYu PVC 30610PKX-J-XFISYu XLPE

18 10 0.40 1.52 18.40372

10PKX-J-YaISYu PVC 39212PKX-J-XFISYu XLPE

18 12 0.40 1.52 18.93427

12PKX-J-YaISYu PVC 45116PKX-J-XFISYu XLPE

18 16 0.40 1.52 20.72541

16PKX-J-YaISYu PVC 57324PC2-J-XFISYu XLPE

18 24 0.40 1.78 25.58805

24PKX-J-YaISYu PVC 85236PKX-J-XFISYu XLPE

18 36 0.40 1.78 28.901136

36PKX-J-YaISYu PVC 1208

12356 47

MULTI PAIR, XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD, UNARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 40: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 39 Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-H-XFISYu XLPE16 2 0.40 1.27 12.15

13402PKX-H-YaISYu PVC 13904PKX-H-XFISYu XLPE

16 4 0.40 1.27 13.75215

04PKX-H-YaISYu PVC 22406PKX-H-XFISYu XLPE

16 6 0.40 1.27 15.90299

06PKX-H-YaISYu PVC 31308PKX-H-XFISYu XLPE

16 8 0.40 1.52 18.15400

08PKX-H-YaISYu PVC 41810PKX-H-XFISYu XLPE

16 10 0.40 1.52 20.20486

10PKX-H-YaISYu PVC 50912PKX-H-XFISYu XLPE

16 12 0.40 1.52 20.80561

12PKX-H-YaISYu PVC 58916PKX-H-XFISYu XLPE

16 16 0.40 1.52 22.85717

16PKX-H-YaISYu PVC 75424PKX-H-XFISYu XLPE

16 24 0.40 1.78 28.301068

24PKX-H-YaISYu PVC 112536PKX-H-XFISYu XLPE

16 36 0.40 1.78 32.051523

36PKX-H-YaISYu PVC 160802PKX-I-XFISYu XLPE

14 2 0.40 1.27 13.29172

02PKX-I-YaISYu PVC 17804PKX-I-XFISYu XLPE

14 4 0.40 1.27 15.11285

04PKX-I-YaISYu PVC 29606PKX-I-XFISYu XLPE

14 6 0.40 1.52 18.15421

06PKX-I-YaISYu PVC 43808PKX-I-XFISYu XLPE

14 8 0.40 1.52 20.11537

08PKX-I-YaISYu PVC 56010PKX-I-XFISYu XLPE

14 10 0.40 1.52 22.49656

10PKX-I-YaISYu PVC 68512PKX-I-XFISYu XLPE

14 12 0.40 1.52 23019763

12PKX-I-YaISYu PVC 79716PKX-I-XFISYu XLPE

14 16 0.40 1.78 26.091013

16PKX-I-YaISYu PVC 105824PKX-I-XFISYu XLPE

14 24 0.40 1.78 31.731466

24PKX-I-YaISYu PVC 153436PKX-I-XFISYu XLPE

14 36 0.40 2.03 36.602152

36PKX-I-YaISYu PVC 225402PKX-G-XFISYu XLPE

12 2 0.40 1.27 14.70226

02PKX-G-YaISYu PVC 23304PKX-G-XFISYu XLPE

12 4 0.40 1.27 16.82386

04PKX-G-YaISYu PVC 40006PKX-G-XFISYu XLPE

12 6 0.40 1.52 20.25573

06PKX-G-YaISYu PVC 59408PKX-G-XFISYu XLPE 12 8 0.40 1.52 22.55 73608PKX-G-YaISYu PVC 76410PKX-G-XFISYu XLPE

12 10 0.40 1.78 25.87934

10PKX-G-YaISYu PVC 96812PKX-G-XFISYu XLPE

12 12 0.40 1.78 26.651087

12PKX-G-YaISYu PVC 112816PKX-G-XFISYu XLPE

12 16 0.40 1.78 29.401403

16PKX-G-YaISYu PVC 145824PKX-G-XFISYu XLPE

12 24 0.40 2.03 36.502169

24PKX-G-YaISYu PVC 208736PKX-G-XFISYu XLPE

12 36 0.40 2.03 41.503015

36PKX-G-YaISYu PVC 3137

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard cutting length 1000m ± 5%, other lengths are available upon request.

Page 41: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 40Industrial Cables

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

5. Armour: Galvanised Round Steel Wires.6. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Yellow).

SINGLE PAIR XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PKX-J-XFSWYu XLPE18 0.40 0.89 0.90 0.89 10.98

16801PKX-J-YaSWYu PVC 17001PKX-H-XFSWYu XLPE

16 0.40 0.89 0.90 1.02 11.79200

01PKX-H-YaSWYu PVC 20201PKX-I-XFSWYu XLPE

14 0.40 1.02 0.90 1.02 13.26236

01PKX-I-YaSWYu PVC 23901PKX-G-XFSWYu XLPE

12 0.40 1.02 0.90 1.02 14.10287

01PKX-G-YaSWYu PVC 291

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

12346 5

SINGLE PAIR, XLPE/PVC, UNSHIELDED, STEEL WIRE ARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 42: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 41 Industrial Cables

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Screening/Shielding: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

6. Armour: Galvanised Round Steel Wires.7. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Yellow).

SINGLE PAIR XLPE/PVC SHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PKX-J-XFOSSWYu XLPE18 0.40 0.89 0.90 1.02 11.38

18801PKX-J-YaOSSWYu PVC 19001PKX-H-XFOSSWYu XLPE

16 0.40 0.89 0.90 1.02 11.92213

01PKX-H-YaOSSWYu PVC 21501PKX-I-XFOSSWYu XLPE

14 0.40 1.02 0.90 1.02 13.39272

01PKX-I-YaOSSWYu PVC 27601PKX-G-XFOSSWYu XLPE

12 0.40 1.02 0.90 1.02 14.23318

01PKX-G-YaOSSWYu PVC 323

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

12367 5 4

SINGLE PAIR, XLPE/PVC, SHIELDED, ARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 43: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 42Industrial Cables

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

6. Armour: Galvanised Round Steel Wires.7. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Yellow).

MULTI PAIR XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-J-XFSWYu XLPE18 2 0.40 1.02 0.90 1.02 13.62

26502PKX-J-YaSWYu PVC 26804PKX-J-XFSWYu XLPE

18 4 0.40 1.02 0.90 1.27 15.40350

04PKX-J-YaSWYu PVC 35706PKX-J-XFSWYu XLPE

18 6 0.40 1.27 0.90 1.27 17.65460

06PKX-J-YaSWYu PVC 47108PKX-J-XFSWYu XLPE

18 8 0.40 1.27 1.25 1.27 19.70625

08PKX-J-YaSWYu PVC 64010PKX-J-XFSWYu XLPE

18 10 0.40 1.27 1.25 1.27 21.34720

10PKX-J-YaSWYu PVC 73812PKX-J-XFSWYu XLPE

18 12 0.40 1.27 1.25 1.27 21.82780

12PKX-J-YaSWYu PVC 80316PKX-J-XFSWYu XLPE

18 16 0.40 1.52 1.60 1.27 24.661053

16PKX-J-YaSWYu PVC 108324PKX-J-XFSWYu XLPE

18 24 0.40 1.52 1.60 1.27 28.541373

24PKX-J-YaSWYu PVC 141836PKX-J-XFSWYu XLPE

18 36 0.40 1.78 2.0 1.27 32.871954

36PKX-J-YaSWYu PVC 2021

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

12347 6 5

SINGLE PAIR, XLPE/PVC, SHIELDED, ARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 44: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 43 Industrial Cables

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-H-XFSWYu XLPE16 2 0.40 1.02 0.90 1.27 15.04

32502PKX-H-YaSWYu PVC 32904PKX-H-XFSWYu XLPE

16 4 0.40 1.27 0.90 1.27 16.99447

04PKX-H-YaSWYu PVC 45606PKX-H-XFSWYu XLPE

16 6 0.40 1.27 1.25 1.27 19.68648

06PKX-H-YaSWYu PVC 66208PKX-H-XFSWYu XLPE

16 8 0.40 1.27 1.25 1.27 21.23762

08PKX-H-YaSWYu PVC 78010PKX-H-XFSWYu XLPE

16 10 0.40 1.52 1.25 1.27 23.64920

10PKX-H-YaSWYu PVC 94212PKX-H-XFSWYu XLPE

16 12 0.40 1.52 1.60 1.27 24.891118

12PKX-H-YaSWYu PVC 114516PKX-H-XFSWYu XLPE

16 16 0.40 1.52 1.60 1.27 26.741317

16PKX-H-YaSWYu PVC 135324PKX-H-XFSWYu XLPE

16 24 0.40 1.78 2.0 1.27 32.551972

24PKX-H-YaSWYu PVC 202536PKX-H-XFSWYu XLPE

16 36 0.40 1.78 2.0 1.27 35.972479

36PKX-H-YaSWYu PVC 255902PKX-I-XFSWYu XLPE

14 2 0.40 1.27 0.90 1.27 17.52444

02PKX-I-YaSWYu PVC 44804PKX-I-XFSWYu XLPE

14 4 0.40 1.27 1.25 1.27 20.05676

04PKX-I-YaSWYu PVC 69106PKX-I-XFSWYu XLPE

14 6 0.40 1.52 1.25 1.27 23.16894

06PKX-I-YaSWYu PVC 91708PKX-I-XFSWYu XLPE

14 8 0.40 1.52 1.60 1.27 25.851188

08PKX-I-YaSWYu PVC 121810PKX-I-XFSWYu XLPE

14 10 0.40 1.52 1.60 1.27 28.281389

10PKX-I-YaSWYu PVC 142612PKX-I-XFSWYu XLPE

14 12 0.40 1.52 1.60 1.27 28.981504

12PKX-I-YaSWYu PVC 154916PKX-I-XFSWYu XLPE

14 16 0.40 1.78 2.0 1.27 32.442025

16PKX-I-YaSWYu PVC 208524PKX-I-XFSWYu XLPE

14 24 0.40 1.78 2.0 1.27 38.452689

24PKX-I-YaSWYu PVC 277936PKX-I-XFSWYu XLPE

14 36 0.40 2.03 2.50 1.52 44.913928

36PKX-I-YaSWYu PVC 406302PKX-G-XFSWYu XLPE

12 2 0.40 1.27 1.25 1.27 19.60616

02PKX-G-YaSWYu PVC 62504PKX-G-XFSWYu XLPE

12 4 0.40 1.27 1.25 1.27 21.75826

04PKX-G-YaSWYu PVC 84406PKX-G-XFSWYu XLPE

12 6 0.40 1.52 1.60 1.27 25.931237

06PKX-G-YaSWYu PVC 126408PKX-G-XFSWYu XLPE 12 8 0.40 1.52 1.60 1.27 28.23 146508PKX-G-YaSWYu PVC 150110PKX-G-XFSWYu XLPE

12 10 0.40 1.78 2.0 1.27 32.381979

10PKX-G-YaSWYu PVC 202412PKX-G-XFSWYu XLPE

12 12 0.40 1.78 2.0 1.27 33.202152

12PKX-G-YaSWYu PVC 220616PKX-G-XFSWYu XLPE

12 16 0.40 1.78 2.0 1.27 35.952561

16PKX-G-YaSWYu PVC 263324PKX-G-XFSWYu XLPE

12 24 0.40 2.03 2.50 1.52 44.633895

24PKX-G-YaSWYu PVC 400336PKX-G-XFSWYu XLPE

12 36 0.40 2.03 2.50 1.52 49.735064

36PKX-G-YaSWYu PVC 5225

MULTI PAIR XLPE/PVC UNSHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 45: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 44Industrial Cables

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

7. Armour: Galvanised Round Steel Wires.8. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Yellow).

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-J-XFOSSWYu XLPE18 2 0.40 1.02 0.90 1.02 13.98

27902PKX-J-YaOSSWYu PVC 28304PKX-J-XFOSSWYu XLPE

18 4 0.40 1.27 0.90 1.27 16.28395

04PKX-J-YaOSSWYu PVC 40206PKX-J-XFOSSWYu XLPE

18 6 0.40 1.27 0.90 1.27 18.01481

06PKX-J-YaOSSWYu PVC 49208PKX-J-XFOSSWYu XLPE

18 8 0.40 1.27 1.25 1.27 20.06646

08PKX-J-YaOSSWYu PVC 66110PKX-J-XFOSSWYu XLPE

18 10 0.40 1.27 1.25 1.27 21.70741

10PKX-J-YaOSSWYu PVC 75912PKX-J-XFOSSWYu XLPE

18 12 0.40 1.52 1.25 1.27 22.71833

12PKX-J-YaOSSWYu PVC 85516PKX-J-XFOSSWYu XLPE

18 16 0.40 1.52 1.60 1.27 25.051081

16PKX-J-YaOSSWYu PVC 111124PKX-J-XFOSSWYu XLPE

18 24 0.40 1.52 1.60 1.27 28.901403

24PKX-J-YaOSSWYu PVC 144836PKX-J-XFOSSWYu XLPE

18 36 0.40 1.78 2.0 1.27 33.231994

36PKX-J-YaOSSWYu PVC 2061

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

12368 5 47

MULTI PAIR, XLPE/PVC, UNSHIELDED, WITH OVERALL SHIELD, STEEL WIRE ARMOURED, THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 46: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 45 Industrial Cables

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-H-XFOSSWYu XLPE16 2 0.40 1.02 0.90 1.27 15.40

34002PKX-H-YaOSSWYu PVC 34404PKX-H-XFOSSWYu XLPE

16 4 0.40 1.27 0.90 1.27 17.35463

04PKX-H-YaOSSWYu PVC 47106PKX-H-XFOSSWYu XLPE

16 6 0.40 1.27 1.25 1.27 20.05670

06PKX-H-YaOSSWYu PVC 68308PKX-H-XFOSSWYu XLPE

16 8 0.40 1.27 1.25 1.27 21.59783

08PKX-H-YaOSSWYu PVC 80010PKX-H-XFOSSWYu XLPE

16 10 0.40 1.52 1.60 1.27 24.701068

10PKX-H-YaOSSWYu PVC 109012PKX-H-XFOSSWYu XLPE

16 12 0.40 1.52 1.60 1.27 25.251147

12PKX-H-YaOSSWYu PVC 117416PKX-H-XFOSSWYu XLPE

16 16 0.40 1.52 1.60 1.27 27.101331

16PKX-H-YaOSSWYu PVC 136624PKX-H-XFOSSWYu XLPE

16 24 0.40 1.78 2.0 1.27 32.911186

24PKX-H-YaOSSWYu PVC 204036PKX-H-XFOSSWYu XLPE

16 36 0.40 1.78 2.0 1.27 36.322519

36PKX-H-YaOSSWYu PVC 259802PKX-I-XFOSSWYu XLPE

14 2 0.40 1.27 0.90 1.27 17.88457

02PKX-I-YaOSSWYu PVC 46404PKX-I-XFOSSWYu XLPE

14 4 0.40 1.27 1.25 1.27 20.45696

04PKX-I-YaOSSWYu PVC 71106PKX-I-XFOSSWYu XLPE

14 6 0.40 1.52 1.25 1.27 23.52917

06PKX-I-YaOSSWYu PVC 93908PKX-I-XFOSSWYu XLPE

14 8 0.40 1.52 1.60 1.27 26.211201

08PKX-I-YaOSSWYu PVC 123110PKX-I-XFOSSWYu XLPE

14 10 0.40 1.52 1.60 1.27 28.641402

10PKX-I-YaOSSWYu PVC 144012PKX-I-XFOSSWYu XLPE

14 12 0.40 1.52 1.60 1.27 29.341533

12PKX-I-YaOSSWYu PVC 157816PKX-I-XFOSSWYu XLPE

14 16 0.40 1.78 2.0 1.27 33.052064

16PKX-I-YaOSSWYu PVC 212524PKX-I-XFOSSWYu XLPE

14 24 0.40 1.78 2.50 1.27 39.813014

24PKX-I-YaOSSWYu PVC 310536PKX-I-XFOSSWYu XLPE

14 36 0.40 2.03 2.50 1.52 45.273946

36PKX-I-YaOSSWYu PVC 408202PKX-G-XFOSSWYu XLPE

12 2 0.40 1.27 1.25 1.27 19.96637

02PKX-G-YaOSSWYu PVC 64604PKX-G-XFOSSWYu XLPE

12 4 0.40 1.52 1.25 1.27 22.63889

04PKX-G-YaOSSWYu PVC 90606PKX-G-XFOSSWYu XLPE

12 6 0.40 1.52 1.60 1.27 26.291265

06PKX-G-YaOSSWYu PVC 129208PKX-G-XFOSSWYu XLPE 12 8 0.40 1.52 1.60 1.27 28.59 149508PKX-G-YaOSSWYu PVC 153110PKX-G-XFOSSWYu XLPE

12 10 0.40 1.78 2.0 1.27 32.751994

10PKX-G-YaOSSWYu PVC 203912PKX-G-XFOSSWYu XLPE

12 12 0.40 1.78 2.0 1.27 33.562167

12PKX-G-YaOSSWYu PVC 222116PKX-G-XFOSSWYu XLPE

12 16 0.40 1.78 2.0 1.27 36.302601

16PKX-G-YaOSSWYu PVC 267324PKX-G-XFOSSWYu XLPE

12 24 0.40 2.03 2.50 1.52 39.523952

24PKX-G-YaOSSWYu PVC 406036PKX-G-XFOSSWYu XLPE

12 36 0.40 2.03 2.50 1.52 50.835083

36PKX-G-YaOSSWYu PVC 5245

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 47: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 46Industrial Cables

1. Conductor: Thermocouple Extension conductor (see Table 1).

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing: Uniformly twisted insulated

conductors with a suitable twist of lay.4. Individual Screening/Shield: Aluminium-

Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

8. Armour: Galvanised Round Steel Wires.9. Jacket: Heat Resistant Poly Vinyl Chloride

Flame Retardant Sunlight and Oil Resistant (Black).Sunlight and Oil Resistant (Yellow).

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-J-XFISSWYu XLPE18 2 0.40 1.02 0.90 1.27 15.18

33202PKX-J-YaISSWYu PVC 33604PKX-J-XFISSWYu XLPE

18 4 0.40 1.27 0.90 1.27 17.09444

04PKX-J-YaISSWYu PVC 45206PKX-J-XFISSWYu XLPE

18 6 0.40 1.27 1.25 1.27 19.72639

06PKX-J-YaISSWYu PVC 65108PKX-J-XFISSWYu XLPE

18 8 0.40 1.27 1.25 1.27 21.21747

08PKX-J-YaISSWYu PVC 76310PKX-J-XFISSWYu XLPE

18 10 0.40 1.52 1.25 1.27 23.57899

10PKX-J-YaISSWYu PVC 91912PKX-J-XFISSWYu XLPE

18 12 0.40 1.52 1.60 1.27 24.801092

12PKX-J-YaISSWYu PVC 111616PKX-J-XFISSWYu XLPE

18 16 0.40 1.52 1.60 1.27 26.591264

16PKX-J-YaISSWYu PVC 129624PKX-J-XFISSWYu XLPE

18 24 0.40 1.78 2.0 1.27 32.251988

24PKX-J-YaISSWYu PVC 193536PKX-J-XFISSWYu XLPE

18 36 0.40 1.78 2.0 1.27 23.862386

36PKX-J-YaISSWYu PVC 2457

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

12349 6 578

MULTI PAIR, XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD, STEEL WIRE ARMOURED THERMOCOUPLE CABLES

UL 13 / UL 2250, PLTC / ITC, 90°C / 300VTHERMOCOUPLE CABLES

Page 48: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 47 Industrial Cables

SCCItem Code

Insulation Material

Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PKX-H-XFISSWYu XLPE16 2 0.40 1.27 0.90 1.27 16.60

40202PKX-H-YaISSWYu PVC 40704PKX-H-XFISSWYu XLPE

16 4 0.40 1.27 0.90 1.27 18.2056

04PKX-H-YaISSWYu PVC 52606PKX-H-XFISSWYu XLPE

16 6 0.40 1.27 1.25 1.27 21.08755

06PKX-H-YaISSWYu PVC 76908PKX-H-XFISSWYu XLPE

16 8 0.40 1.52 1.25 1.27 23.30915

08PKX-H-YaISSWYu PVC 93410PKX-H-XFISSWYu XLPE

16 10 0.40 1.52 1.60 1.27 26.081191

10PKX-H-YaISSWYu PVC 121512PKX-H-XFISSWYu XLPE

16 12 0.40 1.52 1.60 1.27 26.681284

12PKX-H-YaISSWYu PVC 131316PKX-H-XFISSWYu XLPE

16 16 0.40 1.52 1.60 1.27 28.721516

16PKX-H-YaISSWYu PVC 155324PKX-H-XFISSWYu XLPE

16 24 0.40 1.78 2.0 1.27 34.952289

24PKX-H-YaISSWYu PVC 234636PKX-H-XFISSWYu XLPE

16 36 0.40 1.78 2.50 1.27 39.753199

36PKX-H-YaISSWYu PVC 328402PKX-I-XFISSWYu XLPE

14 2 0.40 1.27 0.90 1.27 17.75466

02PKX-I-YaISSWYu PVC 47204PKX-I-XFISSWYu XLPE

14 4 0.40 1.27 1.25 1.27 20.25716

04PKX-I-YaISSWYu PVC 72706PKX-I-XFISSWYu XLPE

14 6 0.40 1.52 1.25 1.27 23.30937

06PKX-I-YaISSWYu PVC 95408PKX-I-XFISSWYu XLPE

14 8 0.40 1.52 1.60 1.27 25.981242

08PKX-I-YaISSWYu PVC 126510PKX-I-XFISSWYu XLPE

14 10 0.40 1.52 1.60 1.27 28.361453

10PKX-I-YaISSWYu PVC 148112PKX-I-XFISSWYu XLPE

14 12 0.40 1.52 1.60 1.27 29.061580

12PKX-I-YaISSWYu PVC 161416PKX-I-XFISSWYu XLPE

14 16 0.40 1.78 2.0 1.27 32.762123

16PKX-I-YaISSWYu PVC 216824PKX-I-XFISSWYu XLPE

14 24 0.40 1.78 2.0 1.27 38.402830

24PKX-I-YaISSWYu PVC 289836PKX-I-XFISSWYu XLPE

14 36 0.40 2.03 2.50 1.52 44.804136

36PKX-I-YaISSWYu PVC 423702PKX-G-XFISSWYu XLPE

12 2 0.40 1.27 1.25 1.27 19.86646

02PKX-G-YaISSWYu PVC 65304PKX-G-XFISSWYu XLPE

12 4 0.40 1.27 1.25 1.27 21.98867

04PKX-G-YaISSWYu PVC 88006PKX-G-XFISSWYu XLPE

12 6 0.40 1.52 1.60 1.27 26.141279

06PKX-G-YaISSWYu PVC 129908PKX-G-XFISSWYu XLPE 12 8 0.40 1.52 1.60 1.27 28.40 153408PKX-G-YaISSWYu PVC 156110PKX-G-XFISSWYu XLPE

12 10 0.40 1.78 2.0 1.27 32.542042

10PKX-G-YaISSWYu PVC 207612PKX-G-XFISSWYu XLPE

12 12 0.40 1.78 2.0 1.27 33.342225

12PKX-G-YaISSWYu PVC 226616PKX-G-XFISSWYu XLPE

12 16 0.40 1.78 2.0 1.27 36.072656

16PKX-G-YaISSWYu PVC 271024PKX-G-XFISSWYu XLPE

12 24 0.40 2.03 2.50 1.52 44.694031

24PKX-G-YaISSWYu PVC 411336PKX-G-XFISSWYu XLPE

12 36 0.40 2.03 2.50 1.52 49.735262

36PKX-G-YaISSWYu PVC 5385

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For other types of thermocouple, simply replace “KX” to type required in Table 1. 2.) Other jacket materials are available upon request. 3.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 49: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 48Industrial Cables

APPLICATION

• TC Power and Control Tray Cable are intended for use in accordance with Article 336 of NFPA 70, National Electrical Code. Recommended for indoor and outdoor installation in dry and wet locations, in cable racks and trays, in conduits and suitable for direct burial.

• For Transmission of analogue and digital signals in instrument and control systems; UL listed tray cable in compliance with NEC article 336, for use in hazardous classified locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources, e.g. public mains electricity supply.

ELECTRICAL PROPERTIES OF INSTRUMENTATION CABLES – TYPE TC – 600V

Conductor size (AWG) 12 14 16 18

Conductor Resistance @ 20°CPlain Cu

(Ω / km) max.5.63 8.95 14.25 22.80

Tinned Cu 5.83 9.3 14.9 23.6

Mutual Capacitance @ 1 KhzXLPE

(nF/km) max.≤150 ≤150 ≤150 ≤150

PVC ≤250 ≤250 ≤250 ≤250

L/R ratio µH/Ω max. ≤80 ≤60 ≤40 ≤25

Insulation ResistanceXLPE

MΩ – Km min. 30.50 30.50 30.50 30.50PVC

Test Voltage Core/Core (Urms)Core/shield (Urms)

XLPEV max.

3000 3000 3000 3000

PVC 2000 2000 2000 2000

PHYSICAL PROPERTIES

Flame Retardancy Passes UL 1685 vertical tray flame test & IEC 60332-3 Cat.A or C

Sunlight Resistance Passes UL-1581 test (720 hours)

Oil Resistance Passes UL-13 test (Oil I)

Minimum Bending Radius7.5 x Cable Outside Diameter (for unarmoured cables)10 x Cable Outside Diameter (for armoured cables)

Temperature Range (operation)During Operation: -30°C to +90°CDuring Installation: -5°C to +50°C

INSULATION AND JACKET COLOURS

Pair colour Black & White. Other pair colours are available upon request.

Triad colour Black, White and Red. Other triad colours are available upon request.

Jacket colour Orange. Other colours are available upon request.

Single & Multipair and Multi-Triple, individual and/or Collective screen, PVC- sheath

Common Cable Construction:Conductor Type– Plain Copper– Tinned Coated Copper

Insulation Material– XLPE 90°C– PVC 90°C

Unarmoured

Jackets– PVC Flame Retardant, Oil and Sunlight Resistant– Low Smoke Zero Halogen Free

UL 1277, TC, 90°C / 600V, SUNLIGHT & OIL RESISTANT, FLAME RETARDANT

UL 1277, TC, 90°C / 600VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 50: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 49 Industrial Cables

SINGLE PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PC2-I-XFYu XLPE14 0.76 1.14 10.72

9801PC2-I-YaYu PVC 10501PC2-G-XFYu XLPE

12 0.76 1.14 11.66128

01PC2-G-YaYu PVC 135

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01TC2-I-XFOSYu XLPE14 0.76 1.14 11.26

12801TC2-I-YaOSYu PVC 13501TC2-G-XFOSYu XLPE

12 0.76 1.14 12.28171

01TC2-G-YaOSYu PVC 183

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted

insulated conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Yellow).

1234

SINGLE PAIR/TRIAD, XLPE/PVC, UNSHIELDED, UNARMOURED INSTRUMENTATION CABLE

UL 1277, TC, 90°C / 600VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 51: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 50Industrial Cables

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

SINGLE PAIR XLPE/PVC SHIELDED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD XLPE/PVC SHIELDED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted

insulated conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Screening/Shielding: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PC2-I-XFOSYu XLPE14 0.76 1.14 11.08

10601PC2-I-YaOSYu PVC 11501PC2-G-XFOSYu XLPE

12 0.76 1.14 12.02137

01PC2-G-YaOSYu PVC 145

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01TC2-I-XFOSYu XLPE14 0.76 1.14 11.62

13601TC2-I-YaOSYu PVC 15001TC2-G-XFOSYu XLPE

12 0.76 1.14 12.64179

01TC2-G-YaOSYu PVC 195

12345

SINGLE PAIR/TRIAD, XLPE/PVC, SHIELDED UNARMOURED INSTRUMENTATION CABLE

UL 1277, TC, 90°C / 600VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 52: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 51 Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-I-XFYu XLPE14 2 0.76 1.52 15.85

17502PC2-I-YaYu PVC 20004PC2-I-XFYu XLPE

14 4 0.76 1.52 18.17291

04PC2-I-YaYu PVC 33506PC2-I-XFYu XLPE

14 6 0.76 1.52 21.39433

06PC2-I-YaYu PVC 49508PC2-I-XFYu XLPE

14 8 0.76 2.05 25.00553

08PC2-I-YaYu PVC 60010PC2-I-XFYu XLPE

14 10 0.76 2.05 28.05706

10PC2-I-YaYu PVC 79512PC2-I-XFYu XLPE

14 12 0.76 2.05 28.94815

12PC2-I-YaYu PVC 91016PC2-I-XFYu XLPE

14 16 0.76 2.05 31.931043

16PC2-I-YaYu PVC 117024PC2-I-XFYu XLPE

14 24 0.76 2.05 39.141552

24PC2-I-YaYu PVC 175036PC2-I-XFYu XLPE

14 36 0.76 2.80 46.252215

36PC2-I-YaYu PVC 249002PC2-G-XFYu XLPE

12 2 0.76 1.52 17.39234

02PC2-G-YaYu PVC 28004PC2-G-XFYu XLPE

12 4 0.76 1.52 20.04421

04PC2-G-YaYu PVC 48506PC2-G-XFYu XLPE

12 6 0.76 2.05 24.82598

06PC2-G-YaYu PVC 68008PC2-G-XFYu XLPE

12 8 0.76 2.05 27.66799

08PC2-G-YaYu PVC 90510PC2-G-XFYu XLPE

12 10 0.76 2.05 31.14979

10PC2-G-YaYu PVC 110512PC2-G-XFYu XLPE

12 12 0.76 2.05 32.151138

12PC2-G-YaYu PVC 126016PC2-G-XFYu XLPE

12 16 0.76 2.05 32.561507

16PC2-G-YaYu PVC 166024PC2-G-XFYu XLPE

12 24 0.76 2.05 43.762188

24PC2-G-YaYu PVC 240036PC2-G-XFYu XLPE

12 36 0.76 2.80 51.653212

36PC2-G-YaYu PVC 3500

MULTI PAIR XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

12345

MULTI PAIR/TRIAD, XLPE/PVC, UNSHIELDED, UNARMOURED INSTRUMENTATION CABLES

UL 1277, TC, 90°C / 600VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 53: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 52Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-I-XFYu XLPE14 2 0.76 1.52 17.46

26602TC2-I-YaYu PVC 30004TC2-I-XFYu XLPE

14 4 0.76 1.52 20.13446

04TC2-I-YaYu PVC 50006TC2-I-XFYu XLPE

14 6 0.76 2.05 24.93691

06TC2-I-YaYu PVC 78508TC2-I-XFYu XLPE

14 8 0.76 2.05 27.79879

08TC2-I-YaYu PVC 100010TC2-I-XFYu XLPE

14 10 0.76 2.05 31.281074

10TC2-I-YaYu PVC 122012TC2-I-XFYu XLPE

14 12 0.76 2.05 32.301244

12TC2-I-YaYu PVC 141016TC2-I-XFYu XLPE

14 16 0.76 2.05 35.731599

16TC2-I-YaYu PVC 181524TC2-I-XFYu XLPE

14 24 0.76 2.80 45.562476

24TC2-I-YaYu PVC 282036TC2-I-XFYu XLPE

14 36 0.76 2.80 51.913522

36TC2-I-YaYu PVC 400502TC2-G-XFYu XLPE 12 2 0.76 1.52 19.24 35402TC2-G-YaYu PVC 39504TC2-G-XFYu XLPE

12 4 0.76 1.52 22.28612

04TC2-G-YaYu PVC 68006TC2-G-XFYu XLPE

12 6 0.76 2.05 27.60942

06TC2-G-YaYu PVC 105508TC2-G-XFYu XLPE

12 8 0.76 2.05 30.851209

08TC2-G-YaYu PVC 135010TC2-G-XFYu XLPE

12 10 0.76 2.05 34.831484

10TC2-G-YaYu PVC 165512TC2-G-XFYu XLPE

12 12 0.76 2.05 35.991731

12TC2-G-YaYu PVC 193016TC2-G-XFYu XLPE

12 16 0.76 2.05 39.902239

16TC2-G-YaYu PVC 249524TC2-G-XFYu XLPE

12 24 0.76 2.80 50.883447

24TC2-G-YaYu PVC 384536TC2-G-XFYu XLPE

12 36 0.76 2.80 58.124955

36TC2-G-YaYu PVC 5520

MULTI TRIAD XLPE/PVC UNSHIELDED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

Page 54: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 53 Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

12345 6

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-I-XFOSYu XLPE14 2 0.76 1.52 16.21 211

02PC2-I-YaOSYu PVC04PC2-I-XFOSYu XLPE

14 4 0.76 1.52 18.53 33504PC2-I-YaOSYu PVC06PC2-I-XFOSYu XLPE

14 6 0.76 1.52 21.75 46606PC2-I-YaOSYu PVC08PC2-I-XFOSYu XLPE

14 8 0.76 2.05 25.36 65108PC2-I-YaOSYu PVC10PC2-I-XFOSYu XLPE

14 10 0.76 2.05 28.41 78910PC2-I-YaOSYu PVC12PC2-I-XFOSYu XLPE

14 12 0.76 2.05 29.30 90512PC2-I-YaOSYu PVC16PC2-I-XFOSYu XLPE

14 16 0.76 2.05 32.29 114816PC2-I-YaOSYu PVC24PC2-I-XFOSYu XLPE

14 24 0.76 2.05 39.50 164924PC2-I-YaOSYu PVC36PC2-I-XFOSYu XLPE

14 36 0.76 2.80 46.61 250436PC2-I-YaOSYu PVC02PC2-G-XFOSYu XLPE

12 2 0.76 1.52 17.75 27202PC2-G-YaOSYu PVC04PC2-G-XFOSYu XLPE

12 4 0.76 1.52 20.40 44904PC2-G-YaOSYu PVC06PC2-G-XFOSYu XLPE

12 6 0.76 2.05 25.18 69206PC2-G-YaOSYu PVC08PC2-G-XFOSYu XLPE

12 8 0.76 2.05 28.02 87808PC2-G-YaOSYu PVC10PC2-G-XFOSYu XLPE

12 10 0.76 2.05 31.50 107010PC2-G-YaOSYu PVC12PC2-G-XFOSYu XLPE

12 12 0.76 2.05 32.51 123712PC2-G-YaOSYu PVC16PC2-G-XFOSYu XLPE

12 16 0.76 2.05 35.92 158516PC2-G-YaOSYu PVC24PC2-G-XFOSYu XLPE

12 24 0.76 2.05 44.12 229524PC2-G-YaOSYu PVC36PC2-G-XFOSYu XLPE

12 36 0.76 2.80 52.01 347836PC2-G-YaOSYu PVC

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

MULTI PAIR/TRIAD, XLPE/PVC, UNSHIELDED WITH OVERALL SHIELD, UNARMOURED INSTRUMENTATION CABLES

UL 1277, TC, 90°C / 600VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 55: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 54Industrial Cables

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-I-XFOSYu XLPE14 2 0.76 1.52 17.82 276

02TC2-I-YaOSYu PVC04TC2-I-XFOSYu XLPE

14 4 0.76 1.52 20.49 45704TC2-I-YaOSYu PVC06TC2-I-XFOSYu XLPE

14 6 0.76 2.05 25.29 70406TC2-I-YaOSYu PVC08TC2-I-XFOSYu XLPE

14 8 0.76 2.05 28.15 89308TC2-I-YaOSYu PVC10TC2-I-XFOSYu XLPE

14 10 0.76 2.05 31.64 108910TC2-I-YaOSYu PVC12TC2-I-XFOSYu XLPE

14 12 0.76 2.05 32.66 125912TC2-I-YaOSYu PVC16TC2-I-XFOSYu XLPE

14 16 0.76 2.05 36.09 161416TC2-I-YaOSYu PVC24TC2-I-XFOSYu XLPE

14 24 0.76 2.80 45.92 249524TC2-I-YaOSYu PVC36TC2-I-XFOSYu XLPE

14 36 0.76 2.80 52.27 354336TC2-I-YaOSYu PVC02TC2-G-XFOSYu XLPE

12 2 0.76 1.52 19.60 36502TC2-G-YaOSYu PVC04TC2-G-XFOSYu XLPE

12 4 0.76 1.52 22.64 62304TC2-G-YaOSYu PVC06TC2-G-XFOSYu XLPE

12 6 0.76 2.05 27.96 95006TC2-G-YaOSYu PVC08TC2-G-XFOSYu XLPE

12 8 0.76 2.05 31.21 122408TC2-G-YaOSYu PVC10TC2-G-XFOSYu XLPE

12 10 0.76 2.05 35.19 149910TC2-G-YaOSYu PVC12TC2-G-XFOSYu XLPE

12 12 0.76 2.05 36.35 174612TC2-G-YaOSYu PVC16TC2-G-XFOSYu XLPE

12 16 0.76 2.05 40.26 225616TC2-G-YaOSYu PVC24TC2-G-XFOSYu XLPE

12 24 0.76 2.80 21.24 346724TC2-G-YaOSYu PVC36TC2-G-XFOSYu XLPE

12 36 0.76 2.80 58.48 497736TC2-G-YaOSYu PVC

MULTI TRIAD XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/Triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard cutting length 1000m ± 5%. Other lengths are available upon request.

Page 56: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 55 Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC FR 90°C, XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Individual Screening/Shield : Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Jacket: Heat Resistant Poly Vinyl Chloride Flame Retardant Sunlight and Oil Resistant (Black).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-I-XFISYu XLPE14 2 0.76 1.52 16.86 232

02PC2-I-YaISYu PVC04PC2-I-XFISYu XLPE

14 4 0.76 1.52 19.33 37404PC2-I-YaISYu PVC06PC2-I-XFISYu XLPE

14 6 0.76 1.52 22.74 52306PC2-I-YaISYu PVC08PC2-I-XFISYu XLPE

14 8 0.76 2.05 26.50 72808PC2-I-YaISYu PVC10PC2-I-XFISYu XLPE

14 10 0.76 2.05 29.73 88410PC2-I-YaISYu PVC12PC2-I-XFISYu XLPE

14 12 0.76 2.05 30.67 101712PC2-I-YaISYu PVC16PC2-I-XFISYu XLPE

14 16 0.76 2.05 33.84 129516PC2-I-YaISYu PVC24PC2-I-XFISYu XLPE

14 24 0.76 2.05 41.47 186524PC2-I-YaISYu PVC36PC2-I-XFISYu XLPE

14 36 0.76 2.80 48.92 283036PC2-I-YaISYu PVC02PC2-G-XFISYu XLPE

12 2 0.76 1.52 18.44 29502PC2-G-YaISYu PVC04PC2-G-XFISYu XLPE

12 4 0.76 1.52 21.24 49104PC2-G-YaISYu PVC06PC2-G-XFISYu XLPE

12 6 0.76 2.05 26.23 75606PC2-G-YaISYu PVC08PC2-G-XFISYu XLPE

12 8 0.76 2.05 29.22 96008PC2-G-YaISYu PVC10PC2-G-XFISYu XLPE

12 10 0.76 2.05 32.89 117210PC2-G-YaISYu PVC12PC2-G-XFISYu XLPE

12 12 0.76 2.05 33.95 135712PC2-G-YaISYu PVC16PC2-G-XFISYu XLPE

12 16 0.76 2.05 37.55 174216PC2-G-YaISYu PVC24PC2-G-XFISYu XLPE

12 24 0.76 2.80 47.78 269024PC2-G-YaISYu PVC36PC2-G-XFISYu XLPE

12 36 0.76 2.80 54.44 382836PC2-G-YaISYu PVC

MULTI PAIR XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

12356 47

MULTI PAIR/TRIAD, XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD, UNARMOURED INSTRUMENTATION CABLES

UL 1277, TC, 90°C / 600VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 57: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 56Industrial Cables

SCCItem Code

Insulation Material Type

Conductor size

(AWG)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-I-XFISYu XLPE14 2 0.76 1.52 19.28 304

02TC2-I-YaISYu PVC04TC2-I-XFISYu XLPE

14 4 0.76 1.52 22.25 50304TC2-I-YaISYu PVC06TC2-I-XFISYu XLPE

14 6 0.76 2.05 27.48 75506TC2-I-YaISYu PVC08TC2-I-XFISYu XLPE

14 8 0.76 2.05 30.66 95408TC2-I-YaISYu PVC10TC2-I-XFISYu XLPE

14 10 0.76 2.05 34.56 120010TC2-I-YaISYu PVC12TC2-I-XFISYu XLPE

14 12 0.76 2.05 35.69 138812TC2-I-YaISYu PVC16TC2-I-XFISYu XLPE

14 16 0.76 2.05 39.51 178016TC2-I-YaISYu PVC24TC2-I-XFISYu XLPE 14 24 0.76 2.80 50.28 275124TC2-I-YaISYu PVC36TC2-I-XFISYu XLPE

14 36 0.76 2.80 57.36 390736TC2-I-YaISYu PVC02TC2-G-XFISYu XLPE

12 2 0.76 1.52 21.20 39502TC2-G-YaISYu PVC04TC2-G-XFISYu XLPE

12 4 0.76 2.05 25.69 73304TC2-G-YaISYu PVC06TC2-G-XFISYu XLPE

12 6 0.76 2.05 30.35 103306TC2-G-YaISYu PVC08TC2-G-XFISYu XLPE

12 8 0.76 2.05 33.97 132208TC2-G-YaISYu PVC10TC2-G-XFISYu XLPE

12 10 0.76 2.05 38.39 162010TC2-G-YaISYu PVC12TC2-G-XFISYu XLPE

12 12 0.76 2.05 39.68 188512TC2-G-YaISYu PVC16TC2-G-XFISYu XLPE

12 16 0.76 2.05 44.02 243516TC2-G-YaISYu PVC24TC2-G-XFISYu XLPE

12 24 0.76 2.80 56.04 374424TC2-G-YaISYu PVC36TC2-G-XFISYu XLPE

12 36 0.76 2.80 64.08 537036TC2-G-YaISYu PVC

MULTI TRIAD XLPE/PVC WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/Triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are on request.

Page 58: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 57 Industrial Cables

A P P L I C A T I O N

• These cables are used in Petrochemical Industries and other process that requires control signals for the transmission of analog and digitals signals to link all the hardware in the networks.

Single & Multipair and Multi-Triple, individual and /or Collective screen, PVC- sheath

Cable Features:Unarmoured

Armoured

Lead Sheathed or Multi-layer Sheathed

Common Cable Construction:Conductor Type– Plain Copper– Tinned Coated Copper

Insulation Material– XLPE 90°C– PVC 90°C

Lead Sheathed or Multi-Layer Sheathed

Armoured– Galvanised Steel Wires– Double Steel Tape

Jackets– PVC Flame Retardant, Oil and Sunlight Resistant– Low Smoke Zero Halogen Free

ELECTRICAL PROPERTIES OF INSTRUMENTATION CABLES – 500V

Conductor area size (mm²) 0.5 0.75 1.0 1.5 2.5

Conductor Resistance @ 20°CPlain Cu

(Ω / km) max.≤36.00 ≤24.50 ≤18.10 ≤12.10 ≤7.41

Tinned Cu ≤36.70 ≤24.80 ≤18.20 ≤12.20 ≤7.56

Mutual Capacitance @ 1 KhzXLPE

(nF/km) max.≤150 ≤150 ≤150 ≤150 ≤150

PVC ≤250 ≤250 ≤250 ≤250 ≤250

L/R ratio µH/Ω max. ≤25 ≤25 ≤25 ≤40 ≤60

Insulation ResistanceXLPE

MΩ – Kmmin. ≥1000 ≥1000 ≥1000 ≥1000 ≥1000

PVC min. ≥10 ≥10 ≥10 ≥10 ≥10

Test Voltage Core/Core (Urms)Core/shield (Urms)

XLPEV min.

≥2000 ≥2000 ≥2000 ≥2000 ≥2000

PVC ≥2000 ≥2000 ≥2000 ≥2000 ≥2000

PHYSICAL PROPERTIES

Flame Retardancy Passes UL 1685 vertical tray flame test & IEC 60332-3 Cat. A or C

Sunlight Resistance Passes UL-1581 test (720 hours)

Oil Resistance Passes UL-13 test (Oil I)/ICEA S-732-532

Minimum Bending Radius7.5 x Cable Outside Diameter (for unarmoured cables)10 x Cable Outside Diameter (for armoured cables)

Temperature RangeDuring Operation: -30°C to +90°CDuring Installation: -5°C to +50°C

INSULATION AND JACKET COLOURS

Pair colour Black & White. Other pair colours are available upon request.

Triad colour Black, White and Red. Other triad colours are available upon request.

Jacket colour Black. Other colours are available upon request.

EN 50288-7, 500V, CROSS LINKED POLYETHYLENE INSULATED CABLES (XLPE 90°C) AND (PVC 90°C) INSULATED CABLES

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 59: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 58Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Jacket: Poly Vinyl Chloride Flame Retardant (Black).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

SINGLE PAIR XLPE/PVC SHIELDED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD XLPE/PVC SHIELDED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/

km)01PC2-A-2XOSYu XLPE

0.50.50

0.807.45 43

01PC2-A-YaOSYu PVC 0.60 7.85 5001PC2-B-2XOSYu XLPE

0.75 0.60 0.80 8.2554

01PC2-B-YaOSYu PVC 5801PC2-C-2XOSYu XLPE

1.0 0.60 0.80 8.6061

01PC2-C-YaOSYu PVC 6501PC2-D-XFOSYu XLPE

1.5 0.60 0.80 9.1573

01PC2-D-YaOSYu PVC 7801PC2-E-XFOSYu XLPE

2.5 0.70 0.90 10.25101

01PC2-E-YaOSYu PVC 107

SCCItem Code

Insulation Material Type

Conductor size (mm2)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/

km)01TC2-A-2XOSYu XLPE

0.50.50

0.807.75 51

01TC2-A-YaOSYu PVC 0.60 8.20 6101TC2-B-2XOSYu XLPE

0.75 0.60 0.80 8.6566

01TC2-B-YaOSYu PVC 7201TC2-C-2XOSYu XLPE

1.0 0.60 0.80 9.0076

01TC2-C-YaOSYu PVC 8201TC2-D-2XOSYu XLPE

1.5 0.60 0.80 9.6094

01TC2-D-YaOSYu PVC 10101TC2-E-2XOSYu XLPE

2.5 0.70 0.80 10.75132

01TC2-E-YaOSYu PVC 141

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

12345

SINGLE PAIR/TRIAD SHIELDED, UNARMOURED INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 60: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 59 Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay, applied with polyester wrapping tape.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

6. Armour: Galvanised Round Steel Wires.7. Jacket: Poly Vinyl Chloride Flame Retardant

(Black).

SINGLE PAIR SHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD SHIELDED – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

SCCItem Code

Insulation Material

Type

Conductor area size

(mm2)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01PC2-A-2XOSSWYu XLPE0.5

0.500.80 0.90 1.30

12.00 21101PC2-A-YaOSSWYu PVC 0.60 12.40 23101PC2-B-2XOSSWYu XLPE

0.75 0.60 0.80 0.90 1.30 12.80243

01PC2-B-YaOSSWYu PVC 24701PC2-C-2XOSSWYu XLPE

1.0 0.60 0.80 0.90 1.30 13.15257

01PC2-C-YaOSSWYu PVC 26201PC2-D-2XOSSWYu XLPE

1.5 0.60 0.80 0.90 1.40 13.90292

01PC2-D-YaOSSWYu PVC 29701PC2-E-2XOSSWYu XLPE

2.5 0.60 0.90 0.90 1.50 15.20356

01PC2-E-YaOSSWYu PVC 362

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

01TC2-A-2XOSSWYu XLPE0.5

0.500.80 0.90 1.30

12.30 22701TC2-A-YaOSSWYu PVC 0.60 12.70 24901TC2-B-2XOSSWYu XLPE

0.75 0.60 0.80 0.90 1.30 13.15263

01TC2-B-YaOSSWYu PVC 26901TC2-C-2XOSSWYu XLPE

1.0 0.60 0.80 0.90 1.30 13.55286

01TC2-C-YaOSSWYu PVC 29701TC2-D-2XOSSWYu XLPE

1.5 0.60 0.80 0.90 1.40 14.35325

01TC2-D-YaOSSWYu PVC 33301TC2-E-2XOSSWYu XLPE

2.5 0.60 0.90 0.90 1.50 15.70401

01TC2-E-YaOSSWYu PVC 410

12367 5 4

SINGLE PAIR/TRIAD SHIELDED, STEEL WIRE ARMOURED INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 61: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 60Industrial Cables

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Jacket: Poly Vinyl Chloride Flame Retardant (Black).

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-A-2XOSYu XLPE0.5 2

0.500.80

9.90 6902PC2-A-YaOSYu PVC 0.60 10.55 8104PC2-A-2XOSYu XLPE

0.5 40.50

1.1011.85 120

04PC2-A-YaOSYu PVC 0.60 12.65 14408PC2-A-2XOSYu XLPE

0.5 80.50

1.2015.30 204

08PC2-A-YaOSYu PVC 0.60 16.45 25110PC2-A-2XOSYu XLPE

0.5 100.50

1.2017.05 245

10PC2-A-YaOSYu PVC 0.60 18.35 30212PC2-A-2XOSYu XLPE

0.5 120.50

1.2017.55 276

12PC2-A-YaOSYu PVC 0.60 18.90 34424PC2-A-2XOSYu XLPE

0.5 240.50

1.3023.55 497

24PC2-A-YaOSYu PVC 0.60 25.50 62836PC2-A-2XOSYu XLPE

0.5 360.50

1.3026.70 688

36PC2-A-YaOSYu PVC 0.60 29.00 88002PC2-B-2XOSYu XLPE

0.75 2 0.60 0.80 11.2589

02PC2-B-YaOSYu PVC 9704PC2-B-2XOSYu XLPE

0.75 4 0.60 1.20 13.70165

04PC2-B-YaOSYu PVC 18108PC2-B-2XOSYu XLPE

0.75 8 0.60 1.20 17.65276

08PC2-B-YaOSYu PVC 30810PC2-B-2XOSYu XLPE

0.75 10 0.60 1.20 19.75333

10PC2-B-YaOSYu PVC 37212PC2-B-2XOSYu XLPE

0.75 12 0.60 1.20 20.35372

12PC2-B-YaOSYu PVC 42624PC2-B-2XOSYu XLPE

0.75 24 0.60 1.50 28.00724

24PC2-B-YaOSYu PVC 81736PC2-B-2XOSYu XLPE

0.75 36 0.60 1.50 31.851008

36PC2-B-YaOSYu PVC 114802PC2-C-2XOSYu XLPE

1.0 2 0.60 0.80 11.80103

02PC2-C-YaOSYu PVC 11104PC2-C-2XOSYu XLPE

1.0 4 0.60 1.20 14.35192

04PC2-C-YaOSYu PVC 20908PC2-C-2XOSYu XLPE

1.0 8 0.60 1.20 18.60327

08PC2-C-YaOSYu PVC 36110PC2-C-2XOSYu XLPE

1.0 10 0.60 1.20 20.85396

10PC2-C-YaOSYu PVC 43912PC2-C-2XOSYu XLPE

1.0 12 0.60 1.20 21.50453

12PC2-C-YaOSYu PVC 50524PC2-C-XOSYu XLPE

1.0 24 0.60 1.50 29.65870

24PC2-C-YaOSYu PVC 97336PC2-C-XFOSYu XLPE

1.0 36 0.60 1.50 33.751222

36PC2-C-YaOSYu PVC 1377

12345 6

MULTI TWISTED PAIR/TRIAD, UNSHIELDED WITH OVERALL SHIELD, UNARMOURED INSTRUMENTATION CABLES

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 62: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 61 Industrial Cables

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

MULTI PAIR XLPE/PVC UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-A-2XOSYu XLPE0.5 2

0.500.80

10.80 8702TC2-A-YaOSYu PVC 0.60 11.55 10504TC2-A-2XOSYu XLPE

0.5 40.50

1.1012.95 155

04TC2-A-YaOSYu PVC 0.60 13.85 19008TC2-A-2XOSYu XLPE

0.5 80.50

1.2016.90 271

08TC2-A-YaOSYu PVC 0.60 18.20 33810TC2-A-2XOSYu XLPE

0.5 100.50

1.2018.90 327

10TC2-A-YaOSYu PVC 0.60 20.40 41012TC2-A-2XOSYu XLPE

0.5 120.50

1.2019.45 373

12TC2-A-YaOSYu PVC 0.60 21.00 47124TC2-A-2XOSYu XLPE

0.5 240.50

1.3026.30 685

24TC2-A-YaOSYu PVC 0.60 28.55 87636TC2-A-2XOSYu XLPE

0.5 360.50

1.3029.90 964

36TC2-A-YaOSYu PVC 0.60 32.55 124502TC2-B-2XOSYu XLPE

0.75 2 0.60 0.80 12.35115

02TC2-B-YaOSYu PVC 12704TC2-B-2XOSYu XLPE

0.75 4 0.60 1.20 15.05216

04TC2-B-YaOSYu PVC 24008TC2-B-2XOSYu XLPE

0.75 8 0.60 1.20 19.55374

08TC2-B-YaOSYu PVC 42010TC2-B-2XOSYu XLPE

0.75 10 0.60 1.20 21.95453

10TC2-B-YaOSYu PVC 51212TC2-B-2XOSYu XLPE

0.75 12 0.60 1.20 22.65521

12TC2-B-YaOSYu PVC 59124TC2-B-2XOSYu XLPE

0.75 24 0.60 1.50 31.351003

24TC2-B-YaOSYu PVC 114436TC2-B-2XOSYu XLPE

0.75 36 0.60 1.50 35.701418

36TC2-B-YaOSYu PVC 1629

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-D-XFOSYu XLPE1.5 2 0.60 0.90 12.95

13402PC2-D-YaOSYu PVC 14404PC2-D-XFOSYu XLPE

1.5 4 0.60 1.20 15.45240

04PC2-D-YaOSYu PVC 26008PC2-D-XFOSYu XLPE

1.5 8 0.60 1.30 20.40430

08PC2-D-YaOSYu PVC 47010PC2-D-XFOSYu XLPE

1.5 10 0.60 1.30 22.90522

10PC2-D-YaOSYu PVC 57212PC2-D-XFOSYu XLPE

1.5 12 0.60 1.30 23.65601

12PC2-D-YaOSYu PVC 66024PC2-D-XFOSYu XLPE

1.5 24 0.60 1.50 32.451138

24PC2-D-YaOSYu PVC 125636PC2-D-XFOSYu XLPE

1.5 36 0.60 1.70 37.401657

36PC2-D-YaOSYu PVC 183402PC2-E-XFOSYu XLPE

2.5 2 0.70 1.0 14.55187

02PC2-E-YaOSYu PVC 19904PC2-E-XFOSYu XLPE

2.5 4 0.70 1.30 17.40337

04PC2-E-YaOSYu PVC 36108PC2-E-XFOSYu XLPE

2.5 8 0.70 1.40 23.00613

08PC2-E-YaOSYu PVC 66010PC2-E-XFOSYu XLPE

2.5 10 0.70 1.40 25.90747

10PC2-E-YaOSYu PVC 80712PC2-E-XFOSYu XLPE

2.5 12 0.70 1.40 26.75865

12PC2-E-YaOSYu PVC 93624PC2-E-XFOSYu XLPE

2.5 24 0.70 1.60 36.851651

24PC2-E-YaOSYu PVC 179336PC2-E-XFOSYu XLPE

2.5 36 0.70 1.80 42.552412

36PC2-E-YaOSYu PVC 2625

Page 63: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 62Industrial Cables

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-A-2XOSYu XLPE1.0 2 0.60 0.80 11.80

10302PC2-A-YaOSYu PVC 11104PC2-A-2XOSYu XLPE

1.0 4 0.60 1.20 14.35192

04PC2-A-YaOSYu PVC 20908PC2-A-2XOSYu XLPE

1.0 8 0.60 1.20 18.60327

08PC2-A-YaOSYu PVC 36110PC2-A-2XOSYu XLPE

1.0 10 0.60 1.20 20.85396

10PC2-A-YaOSYu PVC 43912PC2-A-2XOSYu XLPE

1.0 12 0.60 1.20 21.50453

12PC2-A-YaOSYu PVC 50524PC2-A-2XOSYu XLPE

1.0 24 0.60 1.50 29.65870

24PC2-A-YaOSYu PVC 97336PC2-A-2XOSYu XLPE

1.0 36 0.60 1.50 33.751222

36PC2-A-YaOSYu PVC 137702PC2-B-2XOSYu XLPE

1.5 2 0.60 0.90 12.95134

02PC2-B-YaOSYu PVC 14404PC2-B-2XOSYu XLPE

1.5 4 0.60 1.20 15.45240

04PC2-B-YaOSYu PVC 26008PC2-B-2XOSYu XLPE

1.5 8 0.60 1.30 20.40430

08PC2-B-YaOSYu PVC 47010PC2-B-2XOSYu XLPE

1.5 10 0.60 1.30 22.90522

10PC2-B-YaOSYu PVC 57212PC2-B-2XOSYu XLPE

1.5 12 0.60 1.30 23.65601

12PC2-B-YaOSYu PVC 66024PC2-B-2XOSYu XLPE

1.5 24 0.60 1.50 32.451138

24PC2-B-YaOSYu PVC 125636PC2-B-2XOSYu XLPE

1.5 36 0.60 1.70 37.401657

36PC2-B-YaOSYu PVC 183402PC2-C-2XOSYu XLPE

2.5 2 0.70 1.0 14.55187

02PC2-C-YaOSYu PVC 19904PC2-C-2XOSYu XLPE

2.5 4 0.70 1.30 17.40337

04PC2-C-YaOSYu PVC 36108PC2-C-2XOSYu XLPE

2.5 8 0.70 1.40 23.00613

08PC2-C-YaOSYu PVC 66010PC2-C-2XOSYu XLPE

2.5 10 0.70 1.40 25.90747

10PC2-C-YaOSYu PVC 80712PC2-C-2XOSYu XLPE

2.5 12 0.70 1.40 26.75865

12PC2-C-YaOSYu PVC 93624PC2-C-XOSYu XLPE

2.5 24 0.70 1.60 36.851651

24PC2-C-YaOSYu PVC 179336PC2-C-XFOSYu XLPE

2.5 36 0.70 1.80 42.552412

36PC2-C-YaOSYu PVC 2625

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 64: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 63 Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Jacket: Poly Vinyl Chloride Flame Retardant (Black).

MULTI PAIR WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-A-2XISYu XLPE0.5 2

0.500.90

10.65 9002PC2-A-YaISYu PVC 0.60 11.35 10304PC2-A-2XISYu XLPE

0.5 40.50

1.2012.75 158

04PC2-A-YaISYu PVC 0.60 13.55 18308PC2-A-2XISYu XLPE

0.5 80.50

1.2016.25 267

08PC2-A-YaISYu PVC 0.60 17.40 31310PC2-A-2XISYu XLPE

0.5 100.50

1.2018.10 322

10PC2-A-YaISYu PVC 0.60 19.45 37912PC2-A-2XISYu XLPE

0.5 120.50

1.2018.65 367

12PC2-A-YaISYu PVC 0.60 20.05 43524PC2-A-2XISYu XLPE

0.5 240.50

1.3025.15 676

24PC2-A-YaISYu PVC 0.60 27.20 80736PC2-A-2XISYu XLPE

0.5 360.50

1.5029.00 983

36PC2-A-YaISYu PVC 0.60 31.35 117702PC2-B-2XISYu XLPE

0.75 2 0.60 1.10 12.45125

02PC2-B-YaISYu PVC 13304PC2-B-2XISYu XLPE

0.75 4 0.60 1.20 14.40200

04PC2-B-YaISYu PVC 21608PC2-B-2XISYu XLPE

0.75 8 0.60 1.30 18.80353

08PC2-B-YaISYu PVC 38510PC2-B-2XISYu XLPE

0.75 10 0.60 1.30 21.05428

10PC2-B-YaISYu PVC 46712PC2-B-2XISYu XLPE

0.75 12 0.60 1.30 21.75490

12PC2-B-YaISYu PVC 53624PC2-B-2XISYu XLPE

0.75 24 0.60 1.70 30.15952

24PC2-B-YaISYu PVC 104536PC2-B-2XISYu XLPE

0.75 36 0.60 2.00 34.901389

36PC2-B-YaISYu PVC 153002PC2-C-2XISYu XLPE

1.0 2 0.60 1.10 13.05140

02PC2-C-YaISYu PVC 14804PC2-C-2XISYu XLPE

1.0 4 0.60 1.20 15.05227

04PC2-C-YaISYu PVC 24408PC2-C-2XISYu XLPE

1.0 8 0.60 1.30 19.80405

08PC2-C-YaISYu PVC 43910PC2-C-2XISYu XLPE

1.0 10 0.60 1.30 22.25491

10PC2-C-YaISYu PVC 53412PC2-C-2XISYu XLPE

1.0 12 0.60 1.30 22.95564

12PC2-C-YaISYu PVC 61624PC2-C-2XISYu XLPE

1.0 24 0.60 1.70 31.851101

24PC2-C-YaISYu PVC 120336PC2-C-2XISYu XLPE

1.0 36 0.60 2.00 36.901610

36PC2-C-YaISYu PVC 1764

12356 47

MULTI TWISTED PAIR/TRIAD WITH INDIVIDUAL AND OVERALL SHIELD, UNARMOURED INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT,FLAME RETARDANT

Page 65: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 64Industrial Cables

MULTI PAIR WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-D-2XISYu XLPE1.5 2 0.60 1.20 14.15

17302PC2-D-YaISYu PVC 18304PC2-D-2XISYu XLPE

1.5 4 0.60 1.30 16.45284

04PC2-D-YaISYu PVC 30408PC2-D-2XISYu XLPE

1.5 8 0.60 1.50 21.85521

08PC2-D-YaISYu PVC 56110PC2-D-2XISYu XLPE

1.5 10 0.60 1.50 24.55633

10PC2-D-YaISYu PVC 68212PC2-D-2XISYu XLPE

1.5 12 0.60 1.50 25.30728

12PC2-D-YaISYu PVC 78724PC2-D-2XISYu XLPE

1.5 24 0.60 1.70 34.701372

24PC2-D-YaISYu PVC 149136PC2-D-2XISYu XLPE

1.5 36 0.60 2.00 40.152014

36PC2-D-YaISYu PVC 219202PC2-E-2XISYu XLPE

2.5 2 0.60 1.30 15.85230

02PC2-E-YaISYu PVC 24204PC2-E-2XISYu XLPE

2.5 4 0.60 1.40 18.40385

04PC2-E-YaISYu PVC 40908PC2-E-2XISYu XLPE

2.5 8 0.60 1.60 24.55713

08PC2-E-YaISYu PVC 76010PC2-E-2XISYu XLPE

2.5 10 0.60 1.60 27.65869

10PC2-E-YaISYu PVC 92812PC2-E-2XISYu XLPE

2.5 12 0.60 1.60 28.551005

12PC2-E-YaISYu PVC 107524PC2-E-2XISYu XLPE

2.5 24 0.60 1.80 39.251907

24PC2-E-YaISYu PVC 204936PC2-E-2XISYu XLPE

2.5 36 0.60 2.10 45.452803

36PC2-E-YaISYu PVC 3016

MULTI TRIAD WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-A-2XISYu XLPE0.5 2

0.500.90

12.05 11202TC2-A-YaISYu PVC 0.60 12.85 13204TC2-A-2XISYu XLPE

0.5 40.50

1.2014.40 198

04TC2-A-YaISYu PVC 0.60 15.40 23608TC2-A-2XISYu XLPE

0.5 80.50

1.2018.65 339

08TC2-A-YaISYu PVC 0.60 20.05 41210TC2-A-2XISYu XLPE

0.5 100.50

1.2020.90 411

10TC2-A-YaISYu PVC 0.60 22.55 50112TC2-A-2XISYu XLPE

0.5 120.50

1.2021.55 472

12TC2-A-YaISYu PVC 0.60 23.25 57824TC2-A-2XISYu XLPE

0.5 240.50

1.3029.35 875

24TC2-A-YaISYu PVC 0.60 31.80 108236TC2-A-2XISYu XLPE

0.5 360.50

1.5033.90 1277

36TC2-A-YaISYu PVC 0.60 36.75 158502TC2-B-2XISYu XLPE

0.75 2 0.60 1.10 14.10156

02TC2-B-YaISYu PVC 16804TC2-B-2XISYu XLPE

0.75 4 0.60 1.20 16.40256

04TC2-B-YaISYu PVC 28008TC2-B-2XISYu XLPE

0.75 8 0.60 1.30 21.70459

08TC2-B-YaISYu PVC 50610TC2-B-2XISYu XLPE

0.75 10 0.60 1.30 24.45558

10TC2-B-YaISYu PVC 61612TC2-B-2XISYu XLPE

0.75 12 0.60 1.30 25.25642

12TC2-B-YaISYu PVC 71224TC2-B-2XISYu XLPE

0.75 24 0.60 1.70 35.151252

24TC2-B-YaISYu PVC 139336TC2-B-2XISYu XLPE

0.75 36 0.60 2.00 40.751833

36TC2-B-YaISYu PVC 2044

Page 66: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 65 Industrial Cables

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-C-2XISYu XLPE1.0 2 0.60 1.10 14.85

17802TC2-C-YaISYu PVC 19004TC2-C-2XISYu XLPE

1.0 4 0.60 1.20 17.25295

04TC2-C-YaISYu PVC 32108TC2-C-2XISYu XLPE

1.0 8 0.60 1.30 22.90534

08TC2-C-YaISYu PVC 58610TC2-C-2XISYu XLPE

1.0 10 0.60 1.30 25.85651

10TC2-C-YaISYu PVC 71512TC2-C-2XISYu XLPE

1.0 12 0.60 1.30 26.65751

12TC2-C-YaISYu PVC 82924TC2-C-2XISYu XLPE

1.0 24 0.60 1.70 37.251470

24TC2-C-YaISYu PVC 162536TC2-C-2XISYu XLPE

1.0 36 0.60 2.00 43.152157

36TC2-C-YaISYu PVC 238902TC2-D-2XISYu XLPE

1.5 2 0.60 1.20 16.15224

02TC2-D-YaISYu PVC 23804TC2-D-2XISYu XLPE

1.5 4 0.60 1.30 18.85375

04TC2-D-YaISYu PVC 40508TC2-D-2XISYu XLPE

1.5 8 0.60 1.50 25.30697

08TC2-D-YaISYu PVC 75710TC2-D-2XISYu XLPE

1.5 10 0.60 1.50 28.50850

10TC2-D-YaISYu PVC 92412TC2-D-2XISYu XLPE

1.5 12 0.60 1.50 29.45983

12TC2-D-YaISYu PVC 107224TC2-D-2XISYu XLPE

1.5 24 0.60 1.70 40.651870

24TC2-D-YaISYu PVC 204736TC2-D-2XISYu XLPE

1.5 36 0.60 2.00 47.152752

36TC2-D-YaISYu PVC 301802TC2-E-2XISYu XLPE

2.5 2 0.60 1.30 18.10303

02TC2-E-YaISYu PVC 32104TC2-E-2XISYu XLPE

2.5 4 0.60 1.40 21.15519

04TC2-E-YaISYu PVC 55908TC2-E-2XISYu XLPE

2.5 8 0.60 1.60 28.50972

08TC2-E-YaISYu PVC 104310TC2-E-2XISYu XLPE

2.5 10 0.60 1.60 32.201189

10TC2-E-YaISYu PVC 127812TC2-E-2XISYu XLPE

2.5 12 0.60 1.60 33.301382

12TC2-E-YaISYu PVC 148924TC2-E-2XISYu XLPE

2.5 24 0.60 1.80 46.102645

24TC2-E-YaISYu PVC 285836TC2-E-2XISYu XLPE

2.5 36 0.60 2.10 53.453900

36TC2-E-YaISYu PVC 4219

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 67: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 66Industrial Cables

MULTI PAIR UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.

4. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

7. Armour: Galvanised Round Steel Wires.8. Jacket: Poly Vinyl Chloride Flame Retardant

(Black).

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-A-2XOSSWYu XLPE0.5 2

0.50 0.80 0.90 1.30 14.50 30002PC2-A-YaOSSWYu PVC 0.60 0.80 0.90 1.30 15.10 32804PC2-A-2XOSSWYu XLPE

0.5 40.50 1.10 0.90 1.40 16.60 410

04PC2-A-YaOSSWYu PVC 0.60 1.10 0.90 1.40 17.40 45108PC2-A-2XOSSWYu XLPE

0.5 80.50 1.20 0.90 1.60 20.45 603

08PC2-A-YaOSSWYu PVC 0.60 1.20 1.25 1.60 22.30 78310PC2-A-2XOSSWYu XLPE

0.5 100.50 1.20 1.25 1.60 22.90 801

10PC2-A-YaOSSWYu PVC 0.60 1.20 1.25 1.60 23.40 90012PC2-A-2XOSSWYu XLPE

0.5 120.50 1.20 1.25 1.60 24.20 847

12PC2-A-YaOSSWYu PVC 0.60 1.20 1.25 1.60 24.75 95724PC2-A-2XOSSWYu XLPE

0.5 240.50 1.30 1.60 1.70 30.30 1438

24PC2-A-YaOSSWYu PVC 0.60 1.30 1.60 1.70 32.30 165236PC2-A-2XOSSWYu XLPE

0.5 360.50 1.30 1.60 1.80 33.65 1774

36PC2-A-YaOSSWYu PVC 0.60 1.30 1.60 1.80 36.00 205202PC2-B-2XOSSWYu XLPE

0.75 2 0.60 0.80 0.90 1.40 16.00364

02PC2-B-YaOSSWYu PVC 37204PC2-B-2XOSSWYu XLPE

0.75 4 0.60 1.20 0.90 1.50 18.65509

04PC2-B-YaOSSWYu PVC 52408PC2-B-2XOSSWYu XLPE

0.75 8 0.60 1.20 1.25 1.70 23.70861

08PC2-B-YaOSSWYu PVC 89210PC2-B-2XOSSWYu XLPE

0.75 10 0.60 1.20 1.60 1.70 26.501112

10PC2-B-YaOSSWYu PVC 115112PC2-B-2XOSSWYu XLPE

0.75 12 0.60 1.20 1.60 1.70 37.101195

12PC2-B-YaOSSWYu PVC 124224PC2-B-2XOSSWYu XLPE

0.75 24 0.60 1.50 1.60 1.80 35.001871

24PC2-B-YaOSSWYu PVC 196436PC2-B-2XOSSWYu XLPE

0.75 36 0.60 1.50 2.00 2.00 40.002584

36PC2-B-YaOSSWYu PVC 272402PC2-C-2XOSSWYu XLPE

1.0 2 0.60 0.80 0.90 1.40 16.55387

02PC2-C-YaOSSWYu PVC 39604PC2-C-2XOSSWYu XLPE

1.0 4 0.60 1.20 0.90 1.50 19.30551

04PC2-C-YaOSSWYu PVC 56908PC2-C-2XOSSWYu XLPE

1.0 8 0.60 1.20 1.25 1.70 24.65941

08PC2-C-YaOSSWYu PVC 97510PC2-C-2XOSSWYu XLPE

1.0 10 0.60 1.20 1.60 1.70 27.601217

10PC2-C-YaOSSWYu PVC 126012PC2-C-2XOSSWYu XLPE

1.0 12 0.60 1.20 1.60 1.70 28.301312

12PC2-C-YaOSSWYu PVC 136424PC2-C-2XOSSWYu XLPE

1.0 24 0.60 1.50 1.60 1.80 36.652081

24PC2-C-YaOSSWYu PVC 218436PC2-C-2XOSSWYu XLPE

1.0 36 0.60 1.50 2.00 2.00 42.002894

36PC2-C-YaOSSWYu PVC 3042

12368 5 47

MULTI TWISTED PAIR/TRIAD, UNSHIELDED WITH OVERALL SHIELD, STEEL WIRE ARMOURED INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT

Page 68: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 67 Industrial Cables

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

MULTI PAIR UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-A-2XOSSWYu XLPE0.5 2

0.50 0.80 0.90 1.30 15.35 34102TC2-A-YaOSSWYu PVC 0.60 0.80 0.90 1.30 16.10 37904TC2-A-2XOSSWYu XLPE

0.5 40.50 1.10 0.90 1.40 18.60 473

04TC2-A-YaOSSWYu PVC 0.60 1.10 0.90 1.40 17.70 53008TC2-A-2XOSSWYu XLPE

0.5 80.50 1.20 0.90 1.60 22.75 818

08TC2-A-YaOSSWYu PVC 0.60 1.20 1.25 1.60 24.05 92510TC2-A-2XOSSWYu XLPE

0.5 100.50 1.20 1.25 1.60 24.75 940

10TC2-A-YaOSSWYu PVC 0.60 1.20 1.25 1.60 26.95 101112TC2-A-2XOSSWYu XLPE

0.5 120.50 1.20 1.25 1.60 25.35 1212

12TC2-A-YaOSSWYu PVC 0.60 1.20 1.60 1.60 27.60 129524TC2-A-2XOSSWYu XLPE

0.5 240.50 1.30 1.60 1.70 33.10 1733

24TC2-A-YaOSSWYu PVC 0.60 1.30 1.60 1.70 55.35 202536TC2-A-2XOSSWYu XLPE

0.5 360.50 1.30 1.60 1.80 36.90 2178

36TC2-A-YaOSSWYu PVC 0.60 1.30 2.00 1.80 40.35 280802TC2-B-2XOSSWYu XLPE

0.75 2 0.60 0.80 0.90 1.40 17.10414

02TC2-B-YaOSSWYu PVC 42604TC2-B-2XOSSWYu XLPE

0.75 4 0.60 1.20 0.90 1.50 20.00597

04TC2-B-YaOSSWYu PVC 62008TC2-B-2XOSSWYu XLPE

0.75 8 0.60 1.20 1.25 1.70 26.301150

08TC2-B-YaOSSWYu PVC 119710TC2-B-2XOSSWYu XLPE

0.75 10 0.60 1.20 1.60 1.70 28.701332

10TC2-B-YaOSSWYu PVC 139012TC2-B-2XOSSWYu XLPE

0.75 12 0.60 1.20 1.60 1.70 29.401422

12TC2-B-YaOSSWYu PVC 149324TC2-B-2XOSSWYu XLPE

0.75 24 0.60 1.50 1.60 1.80 39.102505

24TC2-B-YaOSSWYu PVC 264536TC2-B-2XOSSWYu XLPE

0.75 36 0.60 1.50 2.00 2.00 43.903186

36TC2-B-YaOSSWYu PVC 339702TC2-C-2XOSSWYu XLPE

1.0 2 0.60 0.80 0.90 1.40 17.75453

02TC2-C-YaOSSWYu PVC 46604TC2-C-2XOSSWYu XLPE

1.0 4 0.60 1.20 0.90 1.50 51.45750

04TC2-C-YaOSSWYu PVC 77608TC2-C-2XOSSWYu XLPE

1.0 8 0.60 1.20 1.25 1.70 27.401266

08TC2-C-YaOSSWYu PVC 131710TC2-C-2XOSSWYu XLPE

1.0 10 0.60 1.20 1.60 1.70 30.001468

10TC2-C-YaOSSWYu PVC 153212TC2-C-2XOSSWYu XLPE

1.0 12 0.60 1.20 1.60 1.70 30.751591

12TC2-C-YaOSSWYu PVC 166824TC2-C-2XOSSWYu XLPE

1.0 24 0.60 1.50 1.60 1.80 41.052813

24TC2-C-YaOSSWYu PVC 296836TC2-C-2XOSSWYu XLPE

1.0 36 0.60 1.50 2.00 2.00 46.153627

36TC2-C-YaOSSWYu PVC 3858

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-D-2XOSSWYu XLPE1.5 2 0.60 0.90 0.90 1.40 17.65

44802PC2-D-YaOSSWYu PVC 45804PC2-D-2XIOSWYu XLPE

1.5 4 0.60 1.20 0.90 1.60 20.65641

04PC2-D-YaOSSWYu PVC 66008PC2-D-2XOSSWYu XLPE

1.5 8 0.60 1.30 1.60 1.80 37.351261

08PC2-D-YaOSSWYu PVC 130110PC2-D-2XOSSWYu XLPE

1.5 10 0.60 1.30 1.60 1.80 29.901459

10PC2-D-YaOSSWYu PVC 150812PC2-D-2XOSSWYu XLPE

1.5 12 0.60 1.30 1.60 1.80 30.601560

12PC2-D-YOISSWYu PVC 161924PC2-D-2XOSSWYu XLPE

1.5 24 0.60 1.50 2.00 2.00 40.652745

24PC2-D-YaOSSWYu PVC 286436PC2-D-2XOSSWYu XLPE

1.5 36 0.60 1.70 2.00 2.10 45.803543

36PC2-D-YaOSSWYu PVC 372102PC2-E-2XOSSWYu XLPE

2.5 2 0.60 1.00 0.90 1.50 19.50553

02PC2-E-YaOSSWYu PVC 56504PC2-E-2XOSSWYu XLPE

2.5 4 0.60 1.30 1.25 1.70 23.45910

04PC2-E-YaOSSWYu PVC 93308PC2-E-2XOSSWYu XLPE

2.5 8 0.60 1.40 1.60 1.90 30.701567

08PC2-E-YaOSSWYu PVC 161410PC2-E-2XOSSWYu XLPE

2.5 10 0.60 1.40 1.60 1.90 33.101812

10PC2-E-YaOSSWYu PVC 187112PC2-E-2XOSSWYu XLPE

2.5 12 0.60 1.40 1.60 1.90 33.951970

12PC2-E-YaOSSWYu PVC 204124PC2-E-2XOSSWYu XLPE

2.5 24 0.60 1.60 2.00 2.10 45.303507

24PC2-E-YaOSSWYu PVC 264936PC2-E-2XOSSWYu XLPE

2.5 36 0.60 1.80 2.50 2.20 52.154984

36PC2-E-YaOSSWYu PVC 5197

Page 69: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 68Industrial Cables

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-D-2XOSSWYu XLPE1.5 2 0.60 0.90 0.90 1.40 19.00

52602TC2-D-YaOSSWYu PVC 54104TC2-D-2XOSSWYu XLPE

1.5 4 0.60 1.20 0.90 1.60 22.95882

04TC2-D-YaOSSWYu PVC 91108TC2-D-2XOSSWYu XLPE

1.5 8 0.60 1.30 1.60 1.80 29.651512

08TC2-D-YaOSSWYu PVC 157110TC2-D-2XOSSWYu XLPE

1.5 10 0.60 1.30 1.60 1.80 32.501767

10TC2-D-YaOSSWYu PVC 184112TC2-D-2XOSSWYu XLPE

1.5 12 0.60 1.30 1.60 1.80 33.351908

12TC2-D-YaOSSWYu PVC 199724TC2-D-2XOSSWYu XLPE

1.5 24 0.60 1.50 2.00 2.00 44.603412

24TC2-D-YaOSSWYu PVC 358936TC2-D-2XOSSWYu XLPE

1.5 36 0.60 1.70 2.00 2.10 51.454858

36TC2-D-YaOSSWYu PVC 512402TC2-E-2XOSSWYu XLPE

2.5 2 0.60 1.00 0.90 1.50 21.75759

02TC2-E-YaOSSWYu PVC 77704TC2-E-2XOSSWYu XLPE

2.5 4 0.60 1.30 1.25 1.70 25.301101

04TC2-E-YaOSSWYu PVC 113708TC2-E-2XOSSWYu XLPE

2.5 8 0.60 1.40 1.60 1.90 32.851918

08TC2-E-YaOSSWYu PVC 198910TC2-E-2XOSSWYu XLPE

2.5 10 0.60 1.40 1.60 1.90 36.152243

10TC2-E-YaOSSWYu PVC 233112TC2-E-2XOSSWYu XLPE

2.5 12 0.60 1.40 1.60 1.90 37.152460

12TC2-E-YaOSSWYu PVC 256624TC2-E-2XOSSWYu XLPE

2.5 24 0.60 1.60 2.00 2.10 50.854850

24TC2-E-YaOSSWYu PVC 506336TC2-E-2XOSSWYu XLPE

2.5 36 0.60 1.80 2.50 2.20 57.556376

36TC2-E-YaOSSWYu PVC 6695

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 70: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 69 Industrial Cables

12349 6 578

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.4. Individual Screening/Shield: Aluminium-

Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

8. Armour: Galvanised Round Steel Wires.9. Jacket: Poly Vinyl Chloride Flame Retardant

(Black).

MULTI TWISTED PAIR/TRIAD WITH INDIVIDUAL AND OVERALL SHIELD, STEEL WIRE ARMOURED INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500V SUNLIGHT & OIL RESISTANT, FLAME RETARDANT

MULTI PAIR WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-A-2XISSWYu XLPE0.5 2

0.50 0.90 0.90 1.40 15.40 34502PC2-A-YaISSWYu PVC 0.60 0.90 0.90 1.40 16.05 37904PC2-A-2XISSWYu XLPE

0.5 40.50 1.20 0.90 1.50 17.65 480

04PC2-A-YaISSWYu PVC 0.60 1.20 0.90 1.50 18.50 52608PC2-A-2XISSWYu XLPE

0.5 80.50 1.20 1.25 1.70 22.30 809

08PC2-A-YaISSWYu PVC 0.60 1.20 1.25 1.70 23.50 88610PC2-A-2XISSWYu XLPE

0.5 100.50 1.20 1.25 1.70 24.20 921

10PC2-A-YaISSWYu PVC 0.60 1.20 1.25 1.70 25.55 103112PC2-A-2XISSWYu XLPE

0.5 120.50 1.20 1.25 1.70 24.75 992

12PC2-A-YaISSWYu PVC 0.60 1.20 1.60 1.70 26.85 123324PC2-A-2XISSWYu XLPE

0.5 240.50 1.30 1.60 1.80 32.15 1698

24PC2-A-YaISSWYu PVC 0.60 1.30 1.60 1.80 34.15 191336PC2-A-2XISSWYu XLPE

0.5 360.50 1.50 1.60 1.90 36.20 2192

36PC2-A-YaISSWYu PVC 0.60 1.50 2.00 1.90 39.35 270102PC2-B-2XISSWYu XLPE

0.75 2 0.60 1.10 0.90 1.50 17.40439

02PC2-B-YaISSWYu PVC 44704PC2-B-2XISSWYu XLPE

0.75 4 0.60 1.20 0.90 1.60 19.55570

04PC2-B-YaISSWYu PVC 58608PC2-B-2XISSWYu XLPE

0.75 8 0.60 1.30 1.25 1.80 25.10993

08PC2-B-YaISSWYu PVC 102410PC2-B-2XISSWYu XLPE

0.75 10 0.60 1.30 1.60 1.80 28.051282

10PC2-B-YaISSWYu PVC 132112PC2-B-2XISSWYu XLPE

0.75 12 0.60 1.30 1.60 1.80 28.751367

12PC2-B-YaISSWYu PVC 141424PC2-B-2XISSWYu XLPE

0.75 24 0.60 1.70 1.60 2.00 37.552225

24PC2-B-YaISSWYu PVC 231936PC2-B-2XISSWYu XLPE

0.75 36 0.60 2.00 2.00 2.20 43.503171

36PC2-B-YaISSWYu PVC 331202PC2-C-2XISSWYu XLPE

1.0 2 0.60 1.10 0.90 1.50 18.00468

02PC2-C-YaISSWYu PVC 47604PC2-C-2XISSWYu XLPE

1.0 4 0.60 1.20 0.90 1.60 20.25619

04PC2-C-YaISSWYu PVC 63608PC2-C-2XISSWYu XLPE

1.0 8 0.60 1.30 1.25 1.80 26.801199

08PC2-C-YaISSWYu PVC 123310PC2-C-2XISSWYu XLPE

1.0 10 0.60 1.30 1.60 1.80 29.201389

10PC2-C-YaISSWYu PVC 143212PC2-C-2XISSWYu XLPE

1.0 12 0.60 1.30 1.60 1.80 29.901501

12PC2-C-YaISSWYu PVC 155324PC2-C-2XISSWYu XLPE

1.0 24 0.60 1.70 1.60 2.00 40.052677

24PC2-C-YaISSWYu PVC 278036PC2-C-2XISSWYu XLPE

1.0 36 0.60 2.00 2.00 2.20 45.503492

36PC2-C-YaISSWYu PVC 3646

Page 71: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 70Industrial Cables

MULTI PAIR WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-D-2XISSWYu XLPE1.5 2 0.60 1.20 0.90 1.60 19.35

54102PC2-D-YaISSWYu PVC 55104PC2-D-2XISSWYu XLPE

1.5 4 0.60 1.30 1.25 1.70 22.50828

04PC2-D-YaISSWYu PVC 84808PC2-D-2XISSWYu XLPE

1.5 8 0.60 1.50 1.60 1.90 29.051416

08PC2-D-YaISSWYu PVC 145510PC2-D-2XISSWYu XLPE

1.5 10 0.60 1.50 1.60 1.90 31.751651

10PC2-D-YaISSWYu PVC 170012PC2-D-2XISSWYu XLPE

1.5 12 0.60 1.50 1.60 1.90 32.501770

12PC2-D-YaISSWYu PVC 182924PC2-D-2XISSWYu XLPE

1.5 24 0.60 1.70 2.00 2.10 43.103128

24PC2-D-YaISSWYu PVC 324636PC2-D-2XISSWYu XLPE

1.5 36 0.60 2.00 2.50 2.40 50.204497

36PC2-D-YaISSWYu PVC 467502PC2-E-2XISSWYu XLPE

2.5 2 0.60 1.30 1.25 1.70 21.90759

02PC2-E-YaISSWYu PVC 77104PC2-E-2XISSWYu XLPE

2.5 4 0.60 1.40 1.25 1.80 24.651010

04PC2-E-YaISSWYu PVC 103408PC2-E-2XISSWYu XLPE

2.5 8 0.60 1.60 1.60 2.00 31.951749

08PC2-E-YaISSWYu PVC 179610PC2-E-2XISSWYu XLPE

2.5 10 0.60 1.60 1.60 2.00 35.052035

10PC2-E-YaISSWYu PVC 209412PC2-E-2XISSWYu XLPE

2.5 12 0.60 1.60 1.60 2.00 35.952212

12PC2-E-YaISSWYu PVC 228324PC2-E-2XISSWYu XLPE

2.5 24 0.60 1.80 2.00 2.20 47.853917

24PC2-E-YaISSWYu PVC 405936PC2-E-2XISSWYu XLPE

2.5 36 0.60 2.10 2.50 2.50 55.705659

36PC2-E-YaISSWYu PVC 5872

MULTI TRIAD WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-A-2XISWFYu XLPE0.5 2 0.60

0.90 0.90 1.40 16.80 40302TC2-A-YaISSWYu PVC 0.90 0.90 1.40 17.60 44504TC2-A-2XISSWYu XLPE

0.5 4 0.601.20 0.90 1.50 19.35 563

04TC2-A-YaISSWYu PVC 1.20 0.90 1.50 20.35 62508TC2-A-2XISSWYu XLPE

0.5 8 0.601.20 1.25 1.70 24.75 964

08TC2-A-YaISSWYu PVC 1.20 1.60 1.70 26.80 121010TC2-A-2XISSWYu XLPE

0.5 10 0.601.20 1.60 1.70 27.70 1249

10TC2-A-YaISSWYu PVC 1.20 1.60 1.70 29.30 140212TC2-A-2XISSWYu XLPE

0.5 12 0.601.20 1.60 1.70 28.35 1352

12TC2-A-YaISSWYu PVC 1.20 1.60 1.70 30.00 150124TC2-A-2XISSWYu XLPE

0.5 24 0.601.30 1.60 1.80 36.35 2068

24TC2-A-YaISSWYu PVC 1.30 2.00 1.80 39.55 261336TC2-A-2XISSWYu XLPE

0.5 36 0.601.50 2.00 1.90 41.90 2927

36TC2-A-YaISSWYu PVC 1.50 2.00 1.90 44.75 338902TC2-B-2XISSWYu XLPE

0.75 2 0.60 1.10 0.90 1.50 19.05514

02TC2-B-YaISSWYu PVC 52604TC2-B-2XISSWYu XLPE

0.75 4 0.60 1.20 1.25 1.60 22.25788

04TC2-B-YaISSWYu PVC 81108TC2-B-2XISSWYu XLPE

0.75 8 0.60 1.30 1.60 1.80 28.701336

08TC2-B-YaISSWYu PVC 138310TC2-B-2XISSWYu XLPE

0.75 10 0.60 1.30 1.60 1.80 31.401557

10TC2-B-YaISSWYu PVC 161612TC2-B-2XISSWYu XLPE

0.75 12 0.60 1.30 1.60 1.80 32.201664

12TC2-B-YaISSWYu PVC 173524TC2-B-2XISSWYu XLPE

0.75 24 0.60 1.70 2.00 2.00 43.352989

24TC2-B-YaISSWYu PVC 312936TC2-B-2XISSWYu XLPE

0.75 36 0.60 2.00 2.50 2.20 50.354305

36TC2-B-YaISSWYu PVC 451602TC2-C-2XISSWYu XLPE

1.0 2 0.60 1.10 0.90 1.50 19.75551

02TC2-C-YaISSWYu PVC 56404TC2-C-2XISSWYu XLPE

1.0 4 0.60 1.20 1.25 1.60 23.10854

04TC2-C-YaISSWYu PVC 88008TC2-C-2XISSWYu XLPE

1.0 8 0.60 1.30 1.60 1.80 29.901471

08TC2-C-YaISSWYu PVC 152210TC2-C-2XISSWYu XLPE

1.0 10 0.60 1.30 1.60 1.80 32.801696

10TC2-C-YaISSWYu PVC 176012TC2-C-2XISSWYu XLPE

1.0 12 0.60 1.30 1.60 1.80 33.651836

12TC2-C-YaISSWYu PVC 191424TC2-C-2XISSWYu XLPE

1.0 24 0.60 1.70 2.00 2.00 45.453330

24TC2-C-YaISSWYu PVC 348436TC2-C-2XISSWYu XLPE

1.0 36 0.60 2.00 2.50 2.00 52.804776

36TC2-C-YaISSWYu PVC 5007

Page 72: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 71 Industrial Cables

MULTI TRIAD WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCCItem Code

Insulation Material

Type

Conductor area size (mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-D-2XISSWYu XLPE1.5 2 0.60 1.20 1.25 1.60 22.00

74402TC2-D-YaISSWYu PVC 75904TC2-D-2XISSWYu XLPE

1.5 4 0.60 1.30 1.25 1.70 24.901001

04TC2-D-YaISSWYu PVC 130108TC2-D-2XISSWYu XLPE

1.5 8 0.60 1.50 1.60 1.90 32.451739

08TC2-D-YaISSWYu PVC 179810TC2-D-2XISSWYu XLPE

1.5 10 0.60 1.50 1.60 1.90 35.702037

10TC2-D-YaISSWYu PVC 211112TC2-D-2XISSWYu XLPE

1.5 12 0.60 1.50 1.60 1.90 36.652197

12TC2-D-YaISSWYu PVC 228624TC2-D-2XISSWYu XLPE

1.5 24 0.60 1.70 2.50 2.10 50.054312

24TC2-D-YaISSWYu PVC 449036TC2-D-2XISSWYu XLPE

1.5 36 0.60 2.00 2.50 2.40 57.155677

36TC2-D-YaISSWYu PVC 594302TC2-E-2XISSWYu XLPE

2.5 2 0.60 1.30 1.25 1.70 24.20902

02TC2-E-YaISSWYu PVC 92004TC2-E-2XISSWYu XLPE

2.5 4 0.60 1.40 1.60 1.80 28.151374

04TC2-E-YaISSWYu PVC 141008TC2-E-2XISSWYu XLPE

2.5 8 0.60 1.60 1.60 2.00 35.902179

08TC2-E-YaISSWYu PVC 225010TC2-E-2XISSWYu XLPE

2.5 10 0.60 1.60 2.00 2.00 40.402797

10TC2-E-YaISSWYu PVC 288212TC2-E-2XISSWYu XLPE

2.5 12 0.60 1.60 2.00 2.00 41.503024

12TC2-E-YaISSWYu PVC 313124TC2-E-2XISSWYu XLPE

2.5 24 0.60 1.80 2.50 2.20 55.705454

24TC2-E-YaISSWYu PVC 566736TC2-E-2XISSWYu XLPE

2.5 36 0.60 2.10 2.50 2.50 63.707256

36TC2-E-YaISSWYu PVC 7575

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are available upon request.

Page 73: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 72Industrial Cables

SINGLE PAIR SHIELDED – LEAD JACKET – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SINGLE TRIAD SHIELDED– LEAD JACKET – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted

insulated conductors with a suitable twist of lay, applied with a polyester wrapping tape.

4. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

6. Lead Jacket: Lead Alloy.

7. Intermediate Jacket: Poly Vinyl Chloride Flame Retardant.

8. Armour: Galvanised Round Steel Wires.9. Jacket: Poly Vinyl Chloride Flame

Retardant (Black).

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Lead Jacket Thickness

(mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

01PC2-A-2XOSLSWYu XLPE0.5

0.500.80 1.10 0.80 0.90 1.30

16.00 64801PC2-A-YaOSLSWYu PVC 0.60 16.35 68001PC2-B-2XOSLSWYu XLPE

0.75 0.60 0.80 1.10 0.80 0.90 1.30 16.80718

01PC2-B-YaOSLSWYu PVC 72201PC2-C-2XOSLSWYu XLPE

1.0 0.60 0.80 1.10 0.80 0.90 1.30 17.15748

01PC2-C-YaOSLSWYu PVC 75301PC2-D-2XOSLSWYu XLPE

1.5 0.60 0.80 1.10 0.90 0.90 1.40 17.90810

01PC2-D-YaOSLSWYu PVC 81501PC2-E-2XOSLSWYu XLPE

2.5 0.60 0.90 1.20 0.90 0.90 1.50 19.60985

01PC2-E-YaOSLSWYu PVC 991

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Lead Jacket Thickness

(mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

01TC2-A-2XOSLSWYu XLPE0.5

0.500.80 1.10 0.80 0.90 1.30

16.30 67801TC2-A-YaOSLSWYu PVC 0.60 16.70 72101TC2-B-2XOSLSWYu XLPE

0.75 0.60 0.80 1.10 0.80 0.90 1.30 17.15755

01TC2-B-YaOSLSWYu PVC 76101TC2-C-2XOSLSWYu XLPE

1.0 0.60 0.80 1.10 0.80 0.90 1.30 17.50794

01TC2-C-YaOSLSWYu PVC 80001TC2-D-2XOSLSWYu XLPE

1.5 0.60 0.80 1.10 0.90 0.90 1.40 18.35964

01TC2-D-YaOSLSWYu PVC 87101TC2-E-2XOSLSWYu XLPE

2.5 0.60 0.90 1.20 0.90 0.90 1.50 20.101056

01TC2-E-YaOSLSWYu PVC 1065

Note: 1. For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2. Other conductor sizes are available and pair/triad counts upon request. 3. Dimensions of cables with Galvanised Double Steel Tape Armour are available upon request. 4. Other jacket materials are available upon request. 5. Standard Cutting length 1000m ± 5%. Other lengths are available upon request.

123456789

SINGLE PAIR/TRIAD SHIELDED, PVC BEDDED, LEAD ALLOY SHEATHED, PVC BEDDED, STEEL WIRE ARMOURED AND PVC SHEATHED INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT / LEAD SHEATHED

Page 74: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 73 Industrial Cables

MULTI TWISTED PAIR/TRIAD, UNSHIELDED, WITH OVERALL SHIELD, PVC BEDDED, LEAD ALLOY SHEATHED, PVC BEDDED, STEEL WIRE ARMOURED AND PVC SHEATHED INSTRUMENTATION CABLE

MULTI PAIR UNSHIELDED WITH OVERALL SHIELD – LEAD JACKET– WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.4. Assembly and wrapping: The required

number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

5. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

6. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

7. Lead Jacket: Lead Alloy.8. Intermediate Jacket: Poly Vinyl Chloride

Flame Retardant.

9. Armour: Galvanised Round Steel Wires.10. Jacket: Poly Vinyl Chloride Flame Retardant

(Black).

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02PC2-A-2XOSLSWYu XLPE0.5 2

0.500.80 1.10 0.80 0.90 1.30

18.45 85002PC2-A-YaOSLSWYu PVC 0.60 19.05 90804PC2-A-2XOSLSWYu XLPE

0.5 40.50

1.10 1.10 0.80 1.25 1.4021.30 1155

04PC2-A-YaOSLSWYu PVC 0.60 22.05 124108PC2-A-2XOSLSWYu XLPE

0.5 80.50

1.20 1.10 1.00 1.60 1.6026.25 1689

08PC2-A-YaOSLSWYu PVC 0.60 27.40 183010PC2-A-2XOSLSWYu XLPE

0.5 100.50

1.20 1.10 1.00 1.60 1.6028.00 1891

10PC2-A-2XOSLSWYu PVC 0.60 29.30 205312PC2-A-2XOSLSWYu XLPE

0.5 120.50

1.20 1.10 1.00 1.60 1.6028.50 1965

12PC2-A-YaOSLSWYu PVC 0.60 29.85 214224PC2-A-2XOSLSWYu XLPE

0.5 240.50

1.30 1.30 1.00 1.60 1.7035.15 2927

24PC2-A-YaOSLSWYu PVC 0.60 37.10 324736PC2-A-2XOSLSWYu XLPE

0.5 360.50

1.30 1.40 1.20 2.00 1.8039.95 3861

36PC2-A-YaOSLSWYu PVC 0.60 42.25 428702PC2-B-2XOSLSWYu XLPE

0.75 2 0.60 0.80 1.10 0.80 0.90 1.40 20.00973

02PC2-B-YaOSLSWYu PVC 98104PC2-B-2XOSLSWYu XLPE

0.75 4 0.60 1.20 1.10 0.80 1.25 1.50 23.351351

04PC2-B-YaOSLSWYu PVC 136608PC2-B-2XOSLSWYu XLPE

0.75 8 0.60 1.20 1.20 1.00 1.60 1.70 29.002059

08PC2-B-YaOSLSWYu PVC 209710PC2-B-2XOSLSWYu XLPE

0.75 10 0.60 1.20 1.20 1.00 1.60 1.70 31.102307

10PC2-B-YaOSLSWYu PVC 234612PC2-B-2XOSLSWYu XLPE

0.75 12 0.60 1.20 1.20 1.00 1.60 1.70 31.752422

12PC2-B-YaOSLSWYu PVC 246924PC2-B-2XOSLSWYu XLPE

0.75 24 0.60 1.50 1.40 1.20 2.00 1.80 41.254037

24PC2-B-YaOSLSWYu PVC 413136PC2-B-2XOSLSWYu XLPE

0.75 36 0.60 1.50 1.60 1.30 2.00 2.00 46.105097

36PC2-B-YaOSLSWYu PVC 523702PC2-C-2XOSLSWYu XLPE

1.0 2 0.60 0.80 1.10 0.80 1.25 1.40 21.251125

02PC2-C-YaOSLSWYu PVC 113404PC2-C-2XOSLSWYu XLPE

1.0 4 0.60 1.20 1.10 0.80 1.25 1.50 24.001433

04PC2-C-YaOSLSWYu PVC 145008PC2-C-2XOSLSWYu XLPE

1.0 8 0.60 1.20 1.20 1.00 1.60 1.70 30.002201

08PC2-C-YaOSLSWYu PVC 223610PC2-C-2XOSLSWYu XLPE

1.0 10 0.60 1.20 1.20 1.00 1.60 1.70 32.252485

10PC2-C-YaOSLSWYu PVC 252812PC2-C-2XOSLSWYu XLPE

1.0 12 0.60 1.20 1.20 1.00 1.60 1.70 32.902599

12PC2-C-YaOSLSWYu PVC 265124PC2-C-2XOSLSWYu XLPE

1.0 24 0.60 1.50 1.40 1.20 2.00 1.80 42.904350

24PC2-C-YaOSLSWYu PVC 445236PC2-C-2XOSLSWYu XLPE

1.0 36 0.60 1.50 1.60 1.30 2.50 2.00 49.055919

36PC2-C-YaOSLSWYu PVC 6074

12345678910

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT / LEAD SHEATHED

Page 75: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 74Industrial Cables

MULTI PAIR UNSHIELDED WITH OVERALL SHIELD – LEAD JACKET – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02PC2-D-2XOSLSWYu XLPE1.5 2 0.60 0.90 1.10 0.80 1.25 1.40 22.35

124702PC2-D-YaOSLSWYu PVC 125704PC2-D-2XOSLSWYu XLPE

1.5 4 0.60 1.20 1.20 1.00 1.60 1.60 26.651815

04PC2-D-YaOSLSWYu PVC 183508PC2-D-2XOSLSWYu XLPE

1.5 8 0.60 1.30 1.30 1.00 1.60 1.80 32.302578

08PC2-D-YaOSLSWYu PVC 261810PC2-D-2XOSLSWYu XLPE

1.5 10 0.60 1.30 1.30 1.00 1.60 1.80 34.702914

10PC2-D-YaOSLSWYu PVC 296312PC2-D-2XOSLSWYu XLPE

1.5 12 0.60 1.30 1.30 1.00 1.60 1.80 35.453056

12PC2-D-YaOSLSWYu PVC 311524PC2-D-2XOSLSWYu XLPE

1.5 24 0.60 1.50 1.60 1.30 2.00 2.00 46.705300

24PC2-D-YaOSLSWYu PVC 541836PC2-D-2XOSLSWYu XLPE

1.5 36 0.60 1.70 1.80 1.40 2.50 2.10 53.557197

36PC2-D-YaOSLSWYu PVC 737502PC2-E-2XOSLSWYu XLPE

2.5 2 0.60 1.00 1.20 0.90 1.25 1.50 24.601522

02PC2-E-YaOSLSWYu PVC 153304PC2-E-2XOSLSWYu XLPE

2.5 4 0.60 1.30 1.30 1.10 1.60 1.70 29.202209

04PC2-E-YaOSLSWYu PVC 223308PC2-E-2XSLSWYu XLPE

2.5 8 0.60 1.40 1.40 1.10 1.60 1.90 25.453161

08PC2-E-YaOSLSWYu PVC 320810PC2-E-2XOSLSWYu XLPE

2.5 10 0.60 1.40 1.40 1.10 2.00 1.90 39.153820

10PC2-E-YaOSLSWYu PVC 387912PC2-E-2XOSLSWYu XLPE

2.5 12 0.60 1.40 1.40 1.10 2.00 1.90 40.004022

12PC2-E-YaOSLSWYu PVC 409324PC2-E-2XOSLSWYu XLPE

2.5 24 0.60 1.60 1.70 1.40 2.50 2.10 52.806954

24PC2-E-YaOSLSWYu PVC 709636PC2-E-2XOSLSWYu XLPE

2.5 36 0.60 1.80 1.90 1.50 2.50 2.20 59.308913

36PC2-E-YaOSLSWYu PVC 9126

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD–LEAD JACKET–WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket

Thickness (nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02TC2-A-2XOSLSWYu XLPE0.5 2

0.50 0.80 1.10 0.80 0.90 1.30 19.35 93302TC2-A-YaOSLSWYu PVC 0.60 0.80 1.10 0.80 1.25 1.30 20.05 110404TC2-A-2XOSLSWYu XLPE

0.5 40.50 1.10 1.10 0.80 1.25 1.40 22.40 1270

04TC2-A-YaOSLSWYu PVC 0.60 1.10 1.10 0.80 1.25 1.40 23.30 138208TC2-A-2XOSLSWYu XLPE

0.5 80.50 1.20 1.10 1.00 1.60 1.60 27.85 1893

08TC2-A-YaOSLSWYu PVC 0.60 1.20 1.10 1.00 1.60 1.60 29.15 208110TC2-A-2XOSLSWYu XLPE

0.5 100.50 1.20 1.10 1.00 1.60 1.60 29.85 2125

10TC2-A-YaOSLSWYu PVC 0.60 1.20 1.10 1.00 1.60 1.60 31.35 233912TC2-A-2XOSLSWYu XLPE

0.5 120.50 1.20 1.10 1.00 1.60 1.60 30.45 2218

12TC2-A-YaOSLSWYu PVC 0.60 1.20 1.10 1.00 1.60 1.60 32.00 246824TC2-A-2XOSLSWYu XLPE

0.5 240.50 1.30 1.30 1.00 2.00 1.70 38.70 3614

24TC2-A-YaOSLSWYu PVC 0.60 1.30 1.30 1.00 2.00 1.70 40.95 404936TC2-A-2XOSLSWYu XLPE

0.5 360.50 1.30 1.40 1.20 2.00 1.80 43.15 4486

36TC2-A-YaOSLSWYu PVC 0.60 1.30 1.40 1.20 2.00 1.80 45.80 504902TC2-B-2XOSLSWYu XLPE

0.75 2 0.60 0.80 1.10 0.80 1.25 1.40 21.801186

02TC2-B-YaOSLSWYu PVC 119804TC2-B-2XOSLSWYu XLPE

0.75 4 0.60 1.20 1.10 0.80 1.25 1.50 24.651514

04TC2-B-YaOSLSWYu PVC 153708TC2-B-2XOSLSWYu XLPE

0.75 8 0.60 1.20 1.20 1.00 1.60 1.70 30.952337

08TC2-B-YaOSLSWYu PVC 238410TC2-B-2XOSLSWYu XLPE

0.75 10 0.60 1.20 1.20 1.00 1.60 1.70 33.352641

10TC2-B-YaOSLSWYu PVC 269912TC2-B-2XOSLSWYu XLPE

0.75 12 0.60 1.20 1.20 1.00 1.60 1.70 34.052767

12TC2-B-YaOSLSWYu PVC 287324TC2-B-2XOSLSWYu XLPE

0.75 24 0.60 1.50 1.40 1.20 2.00 1.80 44.554674

24TC2-B-YaOSLSWYu PVC 481436TC2-B-2XOSLSWYu XLPE

0.75 36 0.60 1.50 1.60 1.30 2.50 2.00 51.006344

36TC2-B-YaOSLSWYu PVC 6555

Page 76: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 75 Industrial Cables

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD–LEAD JACKET–WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket

Thickness (nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02TC2-C-2XOSLSWYu XLPE1.0 2 0.60 0.80 1.10 0.80 1.25 1.40 22.45

125102TC2-C-YaOSLSWYu PVC 126404TC2-C-2XOSLSWYu XLPE

1.0 4 0.60 1.20 1.10 0.80 1.60 1.50 26.151729

04TC2-C-YaOSLSWYu PVC 175508TC2-C-2XOSLSWYu XLPE

1.0 8 0.60 1.20 1.20 1.00 1.60 1.70 32.052509

08TC2-C-YaOSLSWYu PVC 256110TC2-C-2XOSLSWYu XLPE

1.0 10 0.60 1.20 1.20 1.00 1.60 1.70 34.602843

10TC2-C-YaOSLSWYu PVC 290712TC2-C-2XOSLSWYu XLPE

1.0 12 0.60 1.20 1.20 1.00 1.60 1.70 35.353004

12TC2-C-YaOSLSWYu PVC 308124TC2-C-2XOSLSWYu XLPE

1.0 24 0.60 1.50 1.40 1.20 2.00 1.80 46.505097

24TC2-C-YaOSLSWYu PVC 525136TC2-C-2XOSLSWYu XLPE

1.0 36 0.60 1.50 1.60 1.30 2.50 2.00 53.256950

36TC2-C-YaOSLSWYu PVC 718702TC2-D-2XOSLSWYu XLPE

1.5 2 0.60 0.90 1.10 0.80 1.25 1.40 23.701400

02TC2-D-YaOSLSWYu PVC 141504TC2-D-2XOSLSWYu XLPE

1.5 4 0.60 1.20 1.20 1.00 1.60 1.60 28.252044

04TC2-D-YaOSLSWYu PVC 207308TC2-D-2XOSLSWYu XLPE

1.5 8 0.60 1.30 1.30 1.00 1.60 1.80 34.452970

08TC2-D-YaOSLSWYu PVC 302910TC2-D-2XOSLSWYu XLPE

1.5 10 0.60 1.30 1.30 1.00 1.60 1.80 37.353367

10TC2-D-2XOSLSWYu PVC 344112TC2-D-2XOSLSWYu XLPE

1.5 12 0.60 1.30 1.30 1.00 2.00 1.80 40.003796

12TC2-D-YaOSLSWYu PVC 388424TC2-D-2XOSLSWYu XLPE

1.5 24 0.60 1.50 1.60 1.30 2.50 2.00 51.706632

24TC2-D-YaOSLSWYu PVC 680936TC2-D-2XOSLSWYu XLPE

1.5 36 0.60 1.70 1.80 1.40 2.50 2.10 58.158540

36TC2-D-YaOSLSWYu PVC 880602TC2-E-2XOSLSWYu XLPE

2.5 2 0.60 1.00 1.20 0.90 1.60 1.50 26.851851

02TC2-E-YaOSLSWYu PVC 186904TC2-E-2XOSLSWYu XLPE

2.5 4 0.60 1.30 1.30 1.10 1.60 1.70 31.052503

04TC2-E-YaOSLSWYu PVC 253808TC2-E-2XOSLSWYu XLPE

2.5 8 0.60 1.40 1.40 1.10 2.00 1.90 38.903910

08TC2-E-YaOSLSWYu PVC 398110TC2-E-2XOSLSWYu XLPE

2.5 10 0.60 1.40 1.40 1.10 2.00 1.90 42.204461

10TC2-E-YaOSLSWYu PVC 454912TC2-E-2XOSLSWYu XLPE

2.5 12 0.60 1.40 1.40 1.10 2.00 1.90 43.204727

12TC2-E-YaOSLSWYu PVC 483324TC2-E-2XOSLSWYu XLPE

2.5 24 0.60 1.60 1.70 1.40 2.50 2.10 57.358281

24TC2-E-YaOSLSWYu PVC 849336TC2-E-2XOSLSWYu XLPE

2.5 36 0.60 1.80 1.90 1.50 2.50 2.20 64.6510736

36TC2-E-YaOSLSWYu PVC 11055

Note: 1. For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2. Other conductor sizes are available and pair/triad counts upon request. 3. Dimensions of cables with Galvanised Double Steel Tape Armour are available upon request. 4. Other jacket materials are available upon request. 5. Standard Cutting length 1000m ± 5%. Other lengths are available upon request.

Page 77: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 76Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor.

2. Insulation: PVC 90°C, XLPE 90°C.3. Pairing/Triads: Uniformly twisted

insulated conductors with a suitable twist of lay.

4. Individual Screening/Shield: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Inner Jacket: Poly Vinyl Chloride Flame Retardant.

8. Lead Jacket: Lead Alloy.9. Intermediate Jacket: Poly Vinyl Chloride

Flame Retardant.10. Armour: Galvanised Round Steel

Wires.11. Jacket: Poly Vinyl Chloride Flame

Retardant (Black).

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD–LEAD JACKET–WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket

Thickness (nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02PC2-A-2XISLSWYu XLPE0.5 2

0.50 0.90 1.10 0.80 0.90 1.40 19.40 93202PC2-A-YaISLSWYu PVC 0.60 20.05 99704PC2-A-2XISLSWYu XLPE

0.5 40.50 1.20 1.10 0.80 1.25 1.50 22.35 1271

04PC2-A-YaISLSWYu PVC 0.60 23.15 136008PC2-A-2XISLSWYu XLPE

0.5 80.50 1.20 1.20 1.00 1.60 1.70 27.65 1935

08PC2-A-YaISLSWYu PVC 0.60 28.80 208310PC2-A-2XISLSWYu XLPE

0.5 100.50 1.20 1.20 1.00 1.60 1.70 29.50 2151

10PC2-A-2XISLSWYu PVC 0.60 30.85 233812PC2-A-2XISLSWYu XLPE

0.5 120.50 1.20 1.20 1.00 1.60 1.70 30.05 224

12PC2-A-YaISLSWYu PVC 0.60 31.45 244624PC2-A-2XISLSWYu XLPE

0.5 240.50 1.30 1.40 1.20 2.00 1.80 38.40 3668

24PC2-A-YaISLSWYu PVC 0.60 40.40 401436PC2-A-2XISLSWYu XLPE

0.5 360.50 1.50 1.60 1.30 2.00 1.90 43.10 4702

36PC2-A-YaISLSWYu PVC 0.60 45.45 517902PC2-B-2XISLSWYu XLPE

0.75 2 0.60 1.10 1.10 0.80 1.25 1.50 22.101213

02PC2-B-YaISLSWYu PVC 122104PC2-B-2XISLSWYu XLPE

0.75 4 0.60 1.20 1.20 1.00 1.25 1.60 24.851559

04PC2-B-YaISLSWYu PVC 157508PC2-B-2XISLSWYu XLPE

0.75 8 0.60 1.30 1.30 1.00 1.60 1.80 30.652353

08PC2-B-YaISLSWYu PVC 238410PC2-B-2XISLSWYu XLPE

0.75 10 0.60 1.30 1.30 1.00 1.60 1.80 32.902638

10PC2-B-YaISLSWYu PVC 267712PC2-B-2XISLSWYu XLPE

0.75 12 0.60 1.30 1.40 1.10 1.60 1.80 33.952897

12PC2-B-YaISLSWYu PVC 294424PC2-B-2XISLSWYu XLPE

0.75 24 0.60 1.70 1.60 1.30 2.00 2.00 44.454833

24PC2-B-YaISLSWYu PVC 492736PC2-B-2XISLSWYu XLPE

0.75 36 0.60 2.00 1.80 1.50 2.50 2.20 51.456646

36PC2-B-YaISLSWYu PVC 678702PC2-C-2XISLSWYu XLPE

1.0 2 0.60 1.10 1.10 0.80 1.25 1.50 22.651278

02PC2-C-YaISLSWYu PVC 128704PC2-C-2XISLSWYu XLPE

1.0 4 0.60 1.20 1.20 1.00 1.60 1.60 26.251762

04PC2-C-YaISLSWYu PVC 177908PC2-C-2XISLSWYu XLPE

1.0 8 0.60 1.30 1.30 1.00 1.60 1.80 31.602501

08PC2-C-YaISLSWYu PVC 253510PC2-C-2XISLSWYu XLPE

1.0 10 0.60 1.30 1.30 1.00 1.60 1.80 34.052823

10PC2-C-YaISLSWYu PVC 286612PC2-C-2XISLSWYu XLPE

1.0 12 0.60 1.30 1.30 1.00 1.60 1.80 35.153087

12PC2-C-YaISLSWYu PVC 313824PC2-C-2XISLSWYu XLPE

1.0 24 0.60 1.70 1.60 1.30 2.00 2.00 46.155192

24PC2-C-YaISLSWYu PVC 529536PC2-C-2XISLSWYu XLPE

1.0 36 0.60 2.00 1.80 1.50 2.50 2.20 53.507161

36PC2-C-YaISLSWYu PVC 7315

1234567891011

MULTI TWISTED PAIR/TRIAD, WITH INDIVIDUAL AND OVERALL SHIELD, PVC BEDDED, LEAD ALLOY SHEATHED, PVC BEDDED, STEEL WIRE ARMOURED, AND PVC SHEATHED INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500VSUNLIGHT & OIL RESISTANT, FLAME RETARDANT / LEAD SHEATHED

Page 78: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 77 Industrial Cables

MULTI TRIAD UNSHIELDED WITH OVERALL SHIELD–LEAD JACKET–WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

MULTI TRIAD WITH INDIVIDUAL AND OVERALL SHIELD–LEAD JACKET- WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket

Thickness (nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02PC2-D-2XISLSWYu XLPE1.5 2 0.60 1.20 1.10 1.00 1.25 1.60 24.45

144002PC2-D-YaISLSWYu PVC 145004PC2-D-2XISLSWYu XLPE

1.5 4 0.60 1.30 1.20 1.00 1.60 1.70 27.801963

04PC2-D-YaISLSWYu PVC 198308PC2-D-2XISLSWYu XLPE

1.5 8 0.60 1.50 1.40 1.20 1.60 1.90 34.502972

08PC2-D-YaISLSWYu PVC 301110PC2-D-2XISLSWYu XLPE

1.5 10 0.60 1.50 1.50 1.20 1.60 1.90 37.403470

10PC2-D-YaISLSWYu PVC 352012PC2-D-2XISLSWYu XLPE

1.5 12 0.60 1.50 1.50 1.20 2.00 1.90 38.983881

12PC2-D-YaISLSWYu PVC 394124PC2-D-2XISLSWYu XLPE

1.5 24 0.60 1.70 1.80 1.40 2.50 2.10 50.806558

24PC2-D-YaISLSWYu PVC 667636PC2-D-2XISLSWYu XLPE

1.5 36 0.60 2.00 2.00 1.50 2.50 2.40 57.558410

36PC2-D-YaISLSWYu PVC 858802PC2-E-2XISLSWYu XLPE

2.5 2 0.60 1.30 1.20 1.00 1.60 1.70 27.451869

02PC2-E-YaISLSWYu PVC 188104PC2-E-2XISLSWYu XLPE

2.5 4 0.60 1.40 1.30 1.10 1.60 1.80 30.402370

04PC2-E-YaISLSWYu PVC 239408PC2-E-2XISLSWYu XLPE

2.5 8 0.60 1.60 1.50 1.30 1.60 2.00 37.853591

08PC2-E-YaISLSWYu PVC 363810PC2-E-2XISLSWYu XLPE

2.5 10 0.60 1.60 1.60 1.30 2.00 2.00 41.904452

10PC2-E-YaISLSWYu PVC 451112PC2-E-2XISLSWYu XLPE

2.5 12 0.60 1.60 1.60 1.30 2.00 2.00 42.804708

12PC2-E-YaISLSWYu PVC 477924PC2-E-2XISLSWYu XLPE

2.5 24 0.60 1.80 1.90 1.50 2.50 2.20 56.007945

24PC2-E-YaISLSWYu PVC 808636PC2-E-2XISLSWYu XLPE

2.5 36 0.60 2.10 2.10 1.60 2.50 2.50 63.4510240

36PC2-E-YaISLSWYu PVC 10453

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket

Thickness (nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02TC2-A-2XISLSWYu XLPE0.5 2

0.500.90 1.10 0.80 1.25 1.40

21.50 115802TC2-A-YaISLSWYu PVC 0.60 22.30 124004TC2-A-2XISLSWYu XLPE

0.5 40.50

1.20 1.10 0.80 1.25 1.5024.05 1442

04TC2-A-YaISLSWYu PVC 0.60 25.00 155308TC2-A-2XISLSWYu XLPE

0.5 80.50

1.20 1.20 1.00 1.60 1.7030.05 2217

08TC2-A-YaISLSWYu PVC 0.60 31.45 242210TC2-A-2XISLSWYu XLPE

0.5 100.50

1.20 1.20 1.00 1.60 1.7032.30 2505

10TC2-A-YaISLSWYu PVC 0.60 33.95 274112TC2-A-2XISLSWYu XLPE

0.5 120.50

1.20 1.20 1.00 1.60 1.7032.95 2622

12TC2-A-YaISLSWYu PVC 0.60 34.65 287724TC2-A-2XISLSWYu XLPE

0.5 240.50

1.30 1.40 1.20 2.00 1.8042.60 4333

24TC2-A-YaISLSWYu PVC 0.60 48.00 480836TC2-A-2XISLSWYu XLPE

0.5 360.50

1.50 1.60 1.30 2.50 1.9049.00 5957

36TC2-A-YaISLSWYu PVC 0.60 51.80 660302TC2-B-2XISLSWYu XLPE

0.75 2 0.60 1.10 1.10 0.80 1.25 1.50 23.751375

02TC2-B-YaISLSWYu PVC 138704TC2-B-2XISLSWYu XLPE

0.75 4 0.60 1.20 1.20 1.00 1.60 1.60 27.601919

04TC2-B-YaISLSWYu PVC 194308TC2-B-2XISLSWYu XLPE

0.75 8 0.60 1.30 1.30 1.00 1.60 1.80 33.502741

08TC2-B-YaISLSWYu PVC 278810TC2-B-2XISLSWYu XLPE

0.75 10 0.60 1.30 1.30 1.00 1.60 1.80 36.253095

10TC2-B-YaISLSWYu PVC 315512TC2-B-2XISLSWYu XLPE

0.75 12 0.60 1.30 1.40 1.10 1.60 1.80 37.453386

12TC2-B-YaISLSWYu PVC 345624TC2-B-2XISLSWYu XLPE

0.75 24 0.60 1.70 1.60 1.30 2.50 2.00 50.456098

24TC2-B-YaISLSWYu PVC 623836TC2-B-2XISLSWYu XLPE

0.75 36 0.60 2.00 1.80 1.50 2.50 2.20 57.307921

36TC2-B-YaISLSWYu PVC 8132

Page 79: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 78Industrial Cables

SCC Item CodeInsulation Material

Type

Conductor area size (mm2)

No. of (Triad)

Insulation Thickness

(nom.) (mm)

Inner Jacket

Thickness (nom.) (mm)

Lead Jacket

Thickness (mm)

Intermediate Jacket

Thickness (mm)

Diameter of Armour

Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02TC2-C-2XISLSWYu XLPE1.0 2 0.60 1.10 1.10 0.80 1.25 1.50 24.45

145402TC2-C-YaISLSWYu PVC 146704TC2-C-2XISLSWYu XLPE

1.0 4 0.60 1.20 1.20 1.00 1.60 1.60 28.452040

04TC2-C-YaISLSWYu PVC 206608TC2-C-2XISLSWYu XLPE

1.0 8 0.60 1.30 1.30 1.00 1.60 1.80 34.702927

08TC2-C-YaISLSWYu PVC 297810TC2-C-2XISLSWYu XLPE

1.0 10 0.60 1.30 1.30 1.00 2.00 1.80 38.453545

10TC2-C-YaISLSWYu PVC 360912TC2-C-2XISLSWYu XLPE

1.0 12 0.60 1.30 1.40 1.10 2.00 1.80 39.703879

12TC2-C-YaISLSWYu PVC 395624TC2-C-2XISLSWYu XLPE

1.0 24 0.60 1.70 1.60 1.30 2.50 2.00 52.556597

24TC2-C-YaISLSWYu PVC 675236TC2-C-2XISLSWYu XLPE

1.0 36 0.60 2.00 1.80 1.50 2.50 2.20 59.758578

36TC2-C-YaISLSWYu PVC 881002TC2-D-2XISLSWYu XLPE

1.5 2 0.60 1.20 1.10 1.00 1.60 1.60 27.151787

02TC2-D-YaISLSWYu PVC 180204TC2-D-2XISLSWYu XLPE

1.5 4 0.60 1.30 1.20 1.00 1.60 1.70 30.202279

04TC2-D-YaISLSWYu PVC 230808TC2-D-2XISLSWYu XLPE

1.5 8 0.60 1.50 1.40 1.20 2.00 1.90 38.753719

08TC2-D-YaISLSWYu PVC 377810TC2-D-2XISLSWYu XLPE

1.5 10 0.60 1.50 1.50 1.20 2.00 1.90 42.154365

10TC2-D-2XISLSWYu PVC 443912TC2-D-2XISLSWYu XLPE

1.5 12 0.60 1.50 1.50 1.20 2.00 1.90 43.104592

12TC2-D-YaISLSWYu PVC 468124TC2-D-2XISLSWYu XLPE

1.5 24 0.60 1.70 1.80 1.40 2.50 2.10 56.757849

24TC2-D-YaISLSWYu PVC 802636TC2-D-2XISLSWYu XLPE

1.5 36 0.60 2.00 2.00 1.50 2.50 2.40 64.5010176

36TC2-D-YaISLSWYu PVC 1044202TC2-E-2XISLSWYu XLPE

2.5 2 0.60 1.30 1.20 1.10 1.60 1.70 29.702162

02TC2-E-YaISLSWYu PVC 218004TC2-E-2XISLSWYu XLPE

2.5 4 0.60 1.40 1.30 1.10 1.60 1.80 33.152765

04TC2-E-YaISLSWYu PVC 280108TC2-E-2XISLSWYu XLPE

2.5 8 0.60 1.60 1.50 1.30 2.00 2.00 42.604531

08TC2-E-YaISLSWYu PVC 460210TC2-E-2XISLSWYu XLPE

2.5 10 0.60 1.60 1.60 1.30 2.00 2.00 46.505309

10TC2-E-YaISLSWYu PVC 539812TC2-E-2XISLSWYu XLPE

2.5 12 0.60 1.60 1.60 1.30 2.00 2.00 47.605636

12TC2-E-YaISLSWYu PVC 574324TC2-E-2XISLSWYu XLPE

2.5 24 0.60 1.80 1.90 1.50 2.50 2.50 62.859669

24TC2-E-YaISLSWYu PVC 988136TC2-E-2XISLSWYu XLPE

2.5 36 0.60 2.10 2.10 1.60 2.50 2.50 71.5012585

36TC2-E-YaISLSWYu PVC 12904

MULTI TRIAD WITH INDIVIDUAL AND OVERALL SHIELD–LEAD JACKET- WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS (CONTINUATION)

Note: 1. For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2. Other conductor sizes are available and pair/triad counts upon request. 3. Dimensions of cables with Galvanised Double Steel Tape Armour are available upon request. 4. Other jacket materials are available upon request. 5. Standard Cutting length 1000m ± 5%. Other lengths are available upon request.

Page 80: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 79 Industrial Cables

APPLICATION

• Instrumentation cables installed in an area that has the risk of fire (as in Fire and Gas Area, is required to be fire resistant).

• Such cable has characteristics that it can survive and carry electric signal in case of fire and flame temperature up to 950°C for 3 hours without circuit breakdown shorted or open. (Meets IEC-60331-21 & BS 6387 Cat. C, W, Z)

FIRE RESISTANT, INSTRUMENTATION CABLES

Single & Multipair and Multi-Triple, individual and /or Collective screen, PVC- sheath

Cable Features:Fire resistant cables that complies with IEC 60331 and BS 6387

Low smoke and zero halogen emission

UnarmouredArmoured

Common Cable Construction:Conductor Type– Plain Copper– Tinned Coated Copper

Conductor Wrapping– Mica Tape

Insulation Material– XLPE 90°C

Unarmoured

Armoured– Galvanised Steel Wires– Double Steel Tape

Jackets– Flame Retardant Low Smoke Zero Halogen Free

ELECTRICAL PROPERTIES OF INSTRUMENTATION CABLES – 500V

Conductor area size (mm2) 0.5 0.75 1.0 1.5 2.5

Conductor Resistance @ 20°CPlain Cu

(Ω / km) max.≤36.0 ≤24.5 ≤18.10 ≤12.10 ≤7.41

Tinned Cu ≤36.7 ≤24.8 ≤18.20 ≤12.20 ≤7.56

Mutual Capacitance @ 1 KhzXLPE

(nF/km) max.≤150 ≤150 ≤150 ≤150 ≤150

PVC ≤150 ≤250 ≤250 ≤250 ≤250

L/R ratio µH/Ω max. ≤25 ≤25 ≤25 ≤40 ≤60

Insulation ResistanceXLPE

MΩ – Kmmin. ≥1000 ≥1000 ≥1000 ≥1000 ≥1000

PVC min. ≥10 ≥10 ≥10 ≥10 ≥10

Test Voltage Core/Core (Urms)Core/shield (Urms)

XLPEV min. ≥2000 ≥2000 ≥2000 ≥2000 ≥2000

PVC

PHYSICAL PROPERTIES

Fire ResistantPasses IEC 60331 for 3 hrs @ 750°C

Passes BS 6387 for 3 hrs @ 950°C Category C and Category W, Z

Flame RetardancyPasses Flame Retardant IEC 60332-1 & IEC 60332-3 Cat. A or C

Passes Flame Retardant IEC 60332-3 Cat. A or C

Test Halogen Acid Gases Passes IEC 60754-1

Low smoke emission Passes IEC 61034

Minimum Bending Radius7.5 x Cable Outside Diameter (for unarmoured cables)10 x Cable Outside Diameter (for armoured cables)

Temperature RangeDuring Operation: -30°C to +90°CDuring Installation: -5°C to +50°C

INSULATION AND JACKET COLOURS

Pair colour Black & White. Other pair colours are available upon request.

Triad colour Black, White and Red. Other triad colours are available upon request.

Jacket colour Black. Other colours are available upon request.

EN 50288-7, 90°C / 500VFIRE RESISTANT CABLES

Page 81: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 80Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor, wrapped with Fire Resistant MICA Tape.

2. Insulation: XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted

insulated conductors with a suitable twist of lay.

4. Individual Screening/Shield : Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Jacket: Flame Retardant, Low Smoke Halogen Free (LSHF) (Orange).

The information given in this leaflet is correct to the best of our knowledge and given in good faith, however the right is reserved to make alterations without prior notice.

MULTI PAIR WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material Type

Conductor area size

(mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02PC2-A-FXFISHF XLPE 0.5 2 0.50 0.90 13.10 11504PC2-A-FXFISHF XLPE 0.5 4 0.50 1.20 15.50 20008PC2-A-FXFISHF XLPE 0.5 8 0.50 1.20 20.50 34510PC2-A-FXFISHF XLPE 0.5 10 0.50 1.20 23.10 41012PC2-A-FXFISHF XLPE 0.5 12 0.50 1.20 23.80 48024PC2-A-FXFISHF XLPE 0.5 24 0.50 1.30 32.50 85036PC2-A-FXFISHF XLPE 0.5 36 0.50 1.50 37.50 129002PC2-B-FXFISHF XLPE 0.75 2 0.60 1.10 14.50 15004PC2-B-FXFISHF XLPE 0.75 4 0.60 1.20 17.10 24508PC2-B-FXFISHF XLPE 0.75 8 0.60 1.30 23.10 43010PC2-B-FXFISHF XLPE 0.75 10 0.60 1.30 26.00 54012PC2-B-FXFISHF XLPE 0.75 12 0.60 1.30 27.00 62024PC2-B-FXFISHF XLPE 0.75 24 0.60 1.70 37.50 121036PC2-B-FXFISHF XLPE 0.75 36 0.60 2.00 43.50 175002PC2-C-FXFISHF XLPE 1.0 2 0.60 1.10 15.10 16004PC2-C-FXFISHF XLPE 1.0 4 0.60 1.20 17.50 27008PC2-C-FXFISHF XLPE 1.0 8 0.60 1.30 23.50 47010PC2-C-FXFISHF XLPE 1.0 10 0.60 1.30 26.50 59012PC2-C-FXFISHF XLPE 1.0 12 0.60 1.30 27.50 67024PC2-C-FXFISHF XLPE 1.0 24 0.60 1.70 38.50 132036PC2-C-FXFISHF XLPE 1.0 36 0.60 2.00 45.10 193002PC2-D-FXFISHF XLPE 1.5 2 0.60 1.20 16.50 20004PC2-D-FXFISHF XLPE 1.5 4 0.60 1.30 19.10 33008PC2-D-FXFISHF XLPE 1.5 8 0.60 1.50 25.50 61010PC2-D-FXFISHF XLPE 1.5 10 0.60 1.50 29.10 73512PC2-D-FXFISHF XLPE 1.5 12 0.60 1.50 30.20 84524PC2-D-FXFISHF XLPE 1.5 24 0.60 1.70 41.20 161036PC2-D-FXFISHF XLPE 1.5 36 0.60 2.00 48.50 230002PC2-E-FXFISHF XLPE 2.5 2 0.60 1.30 18.10 25004PC2-E-FXFISHF XLPE 2.5 4 0.60 1.40 19.50 43008PC2-E-FXFISHF XLPE 2.5 8 0.60 1.60 28.50 81010PC2-E-FXFISHF XLPE 2.5 10 0.60 1.60 32.10 98012PC2-E-FXFISHF XLPE 2.5 12 0.60 1.60 33.50 113024PC2-E-FXFISHF XLPE 2.5 24 0.60 1.80 46.30 215036PC2-E-FXFISHF XLPE 2.5 36 0.60 2.10 53.50 3120

12356 47 Illustrations correct?

MULTI PAIR/TRIAD, WITH INDIVIDUAL AND OVERALL SHIELD, UNARMOURED, FIRE RESISTANT INSTRUMENTATION CABLES

EN 50288-7, 90°C / 500VFIRE RESISTANT CABLES

Page 82: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 81 Industrial Cables

MULTI TRIAD WITH INDIVIDUAL AND OVERALL SHIELD CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material Type

Conductor area size

(mm2)

No. of Elements(Triad)

Insulation Thickness

(nom.) (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter

Approx. (mm)

Net Weight Approx. (kg/km)

02TC2-A-FXFISHF XLPE 0.5 2 0.50 0.90 14.50 14004TC2-A-FXFISHF XLPE 0.5 4 0.50 1.20 17.50 25008TC2-A-FXFISHF XLPE 0.5 8 0.50 1.20 23.50 43010TC2-A-FXFISHF XLPE 0.5 10 0.50 1.20 26.50 52012TC2-A-FXFISHF XLPE 0.5 12 0.50 1.20 27.50 60024TC2-A-FXFISHF XLPE 0.5 24 0.50 1.30 38.00 111036TC2-A-FXFISHF XLPE 0.5 36 0.50 1.50 44.00 164002TC2-B-FXFISHF XLPE 0.75 2 0.60 1.10 16.50 18504TC2-B-FXFISHF XLPE 0.75 4 0.60 1.20 19.50 30008TC2-B-FXFISHF XLPE 0.75 8 0.60 1.30 26.50 55010TC2-B-FXFISHF XLPE 0.75 10 0.60 1.30 30.00 68012TC2-B-FXFISHF XLPE 0.75 12 0.60 1.30 31.00 78024TC2-B-FXFISHF XLPE 0.75 24 0.60 1.70 43.50 154036TC2-B-FXFISHF XLPE 0.75 36 0.60 2.00 51.00 226002TC2-C-FXFISHF XLPE 1.0 2 0.60 1.10 17.50 20004TC2-C-FXFISHF XLPE 1.0 4 0.60 1.20 20.50 34008TC2-C-FXFISHF XLPE 1.0 8 0.60 1.30 27.50 63010TC2-C-FXFISHF XLPE 1.0 10 0.60 1.30 31.20 78012TC2-C-FXFISHF XLPE 1.0 12 0.60 1.30 32.40 90024TC2-C-FXFISHF XLPE 1.0 24 0.60 1.70 46.00 178036TC2-C-FXFISHF XLPE 1.0 36 0.60 2.00 53.20 261002TC2-D-FXFISHF XLPE 1.5 2 0.60 1.20 19.00 25004TC2-D-FXFISHF XLPE 1.5 4 0.60 1.30 22.10 42008TC2-D-FXFISHF XLPE 1.5 8 0.60 1.50 30.00 80010TC2-D-FXFISHF XLPE 1.5 10 0.60 1.50 34.10 99012TC2-D-FXFISHF XLPE 1.5 12 0.60 1.50 34.50 115024TC2-D-FXFISHF XLPE 1.5 24 0.60 1.70 49.20 220036TC2-D-FXFISHF XLPE 1.5 36 0.60 2.00 56.50 320002TC2-E-FXFISHF XLPE 2.5 2 0.60 1.30 20.50 31004TC2-E-FXFISHF XLPE 2.5 4 0.60 1.40 24.50 57008TC2-E-FXFISHF XLPE 2.5 8 0.60 1.60 33.10 110010TC2-E-FXFISHF XLPE 2.5 10 0.60 1.60 37.50 135012TC2-E-FXFISHF XLPE 2.5 12 0.60 1.60 38.50 155024TC2-E-FXFISHF XLPE 2.5 24 0.60 1.80 54.20 300036TC2-E-FXFISHF XLPE 2.5 36 0.60 2.10 63.20 4400

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/Triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are on request.

Page 83: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 82Industrial Cables

1. Conductor: Plain/Tinned Stranded Copper conductor, wrapped with Fire Resistant MICA Tape

2. Insulation: XLPE FR 90°C.3. Pairing/Triads: Uniformly twisted insulated

conductors with a suitable twist of lay.4. Individual Screening/Shield: Aluminium-

Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

5. Assembly and wrapping: The required number of pairs/triads are assembled together with non-hygroscopic fillers (if required) and wrapped with a polyester wrapping tape.

6. Overall Screening: Aluminium-Polyester (AL-PET foil) laminated tape with 100% coverage and suitable overlap, metal side in contact with stranded tinned copper drain wire.

7. Inner Jacket: Flame Retardant, Low Smoke Halogen Free (LSHF)

8. Armour: Galvanised Round Steel Wires.9. Jacket: Flame Retardant, Low Smoke

Halogen Free (LSHF) (Orange).

MULTI TWISTED PAIR/TRIAD WITH INDIVIDUAL AND OVERALL SHIELD, STEEL WIRE ARMOURED FIRE RESISTANT INSTRUMENTATION CABLE

EN 50288-7, 90°C / 500VFIRE RESISTANT CABLES

MULTI PAIR WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor area size

(mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Dia. of Armour

Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02PC2-A-FXFISSWHF XLPE 0.5 2 0.50 0.90 0.90 1.40 17.50 41004PC2-A-FXFISSWHF XLPE 0.5 4 0.50 1.20 1.25 1.50 21.00 68008PC2-A-FXFISSWHF XLPE 0.5 8 0.50 1.20 1.60 1.70 27.00 114010PC2-A-FXFISSWHF XLPE 0.5 10 0.50 1.20 1.60 1.70 29.50 131012PC2-A-FXFISSWHF XLPE 0.5 12 0.50 1.20 1.60 1.70 30.10 140024PC2-A-FXFISSWHF XLPE 0.5 24 0.50 1.30 2.00 1.80 40.00 240036PC2-A-FXFISSWHF XLPE 0.5 36 0.50 1.50 2.00 1.90 45.10 305002PC2-B-FXFISSWHF XLPE 0.75 2 0.60 1.10 0.90 1.50 19.80 52704PC2-B-FXFISSWHF XLPE 0.75 4 0.60 1.20 1.25 1.60 22.50 80008PC2-B-FXFISSWHF XLPE 0.75 8 0.60 1.30 1.60 1.80 29.50 136010PC2-B-FXFISSWHF XLPE 0.75 10 0.60 1.30 1.60 1.80 32.50 156012PC2-B-FXFISSWHF XLPE 0.75 12 0.60 1.30 1.60 1.80 33.50 167024PC2-B-FXFISSWHF XLPE 0.75 24 0.60 1.70 2.00 2.00 45.20 301036PC2-B-FXFISSWHF XLPE 0.75 36 0.60 2.00 2.50 2.20 52.50 431002PC2-C-FXFISSWHF XLPE 1.0 2 0.60 1.10 0.90 1.50 19.50 54004PC2-C-FXFISSWHF XLPE 1.0 4 0.60 1.20 1.25 1.60 23.50 84008PC2-C-FXFISSWHF XLPE 1.0 8 0.60 1.30 1.60 1.80 30.50 145010PC2-C-FXFISSWHF XLPE 1.0 10 0.60 1.30 1.60 1.80 33.50 161012PC2-C-FXFISSWHF XLPE 1.0 12 0.60 1.30 1.60 1.80 34.50 179024PC2-C-FXFISSWHF XLPE 1.0 24 0.60 1.70 2.00 2.00 46.50 326036PC2-C-FXFISSWHF XLPE 1.0 36 0.60 2.00 2.50 2.20 54.50 470002PC2-D-FXFISSWHF XLPE 1.5 2 0.60 1.20 1.25 1.60 22.10 72004PC2-D-FXFISSWHF XLPE 1.5 4 0.60 1.30 1.25 1.70 25.00 95008PC2-D-FXFISSWHF XLPE 1.5 8 0.60 1.50 1.60 1.90 32.50 168010PC2-D-FXFISSWHF XLPE 1.5 10 0.60 1.50 1.60 1.90 36.40 195012PC2-D-FXFISSWHF XLPE 1.5 12 0.60 1.50 1.60 1.90 37.50 205024PC2-D-FXFISSWHF XLPE 1.5 24 0.60 1.70 2.50 2.10 51.10 405036PC2-D-FXFISSWHF XLPE 1.5 36 0.60 2.00 2.50 2.40 58.30 520002PC2-E-FXFISSWHF XLPE 2.5 2 0.60 1.30 1.25 1.70 24.10 84004PC2-E-FXFISSWHF XLPE 2.5 4 0.60 1.40 1.25 1.80 28.00 127008PC2-E-FXFISSWHF XLPE 2.5 8 0.60 1.60 1.60 2.00 35.50 201010PC2-E-FXFISSWHF XLPE 2.5 10 0.60 1.60 1.60 2.00 40.10 259012PC2-E-FXFISSWHF XLPE 2.5 12 0.60 1.60 1.60 2.00 41.20 280024PC2-E-FXFISSWHF XLPE 2.5 24 0.60 1.80 2.50 2.20 55.70 495036PC2-E-FXFISSWHF XLPE 2.5 36 0.60 2.10 2.50 2.50 63.80 6500

12349 6 578

Illustrations correct?

Page 84: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 83 Industrial Cables

MULTI TRIAD WITH INDIVIDUAL AND OVERALL SHIELD – WIRE ARMOURED CABLE – DIMENSIONS AND WEIGHTS

SCCItem Code

Insulation Material

Type

Conductor area size

(mm2)

No. of Elements

(Pair)

Insulation Thickness

(nom.) (mm)

Inner Jacket Thickness

(nom.) (mm)

Dia. of Armour

Wire (mm)

Jacket Thickness

(nom.) (mm)

Overall Diameter Approx.

(mm)

Net Weight Approx. (kg/km)

02TC2-A-FXFISSWHF XLPE 0.5 2 0.60 0.90 0.90 1.40 19.20 40304TC2-A-FXFISSWHF XLPE 0.5 4 0.60 1.20 1.25 1.50 23.00 80008TC2-A-FXFISSWHF XLPE 0.5 8 0.60 1.20 1.60 1.70 30.10 135010TC2-A-FXFISSWHF XLPE 0.5 10 0.60 1.20 1.60 1.70 33.20 156012TC2-A-FXFISSWHF XLPE 0.5 12 0.60 1.20 1.60 1.70 34.10 170024TC2-A-FXFISSWHF XLPE 0.5 24 0.60 1.30 2.00 1.80 45.30 297036TC2-A-FXFISSWHF XLPE 0.5 36 0.60 1.50 2.50 1.90 52.70 418002TC2-B-FXFISSWHF XLPE 0.75 2 0.60 1.10 1.25 1.50 22.20 71504TC2-B-FXFISSWHF XLPE 0.75 4 0.60 1.20 1.60 1.60 25.60 105008TC2-B-FXFISSWHF XLPE 0.75 8 0.60 1.30 1.60 1.80 33.60 161010TC2-B-FXFISSWHF XLPE 0.75 10 0.60 1.30 1.60 1.80 36.80 190512TC2-B-FXFISSWHF XLPE 0.75 12 0.60 1.30 2.00 1.80 38.70 224024TC2-B-FXFISSWHF XLPE 0.75 24 0.60 1.70 2.50 2.00 52.50 400536TC2-B-FXFISSWHF XLPE 0.75 36 0.60 2.00 2.50 2.20 60.20 533002TC2-C-2XISSWYu XLPE 1.0 2 0.60 1.10 1.25 1.50 23.00 76004TC2-C-2XISSWYu XLPE 1.0 4 0.60 1.20 1.60 1.60 56.80 115008TC2-C-2XISSWYu XLPE 1.0 8 0.60 1.30 1.60 1.80 34.40 174010TC2-C-2XISSWYu XLPE 1.0 10 0.60 1.30 1.60 1.80 38.80 231012TC2-C-2XISSWYu XLPE 1.0 12 0.60 1.30 2.00 1.80 40.10 248624TC2-C-2XISSWYu XLPE 1.0 24 0.60 1.70 2.50 2.00 54.60 444436TC2-C-2XISSWYu XLPE 1.0 36 0.60 2.00 2.50 2.20 62.60 584502TC2-D-2XISSWYu XLPE 1.5 2 0.60 1.20 1.25 1.60 24.60 85004TC2-D-2XISSWYu XLPE 1.5 4 0.60 1.30 1.60 1.70 28.70 131508TC2-D-2XISSWYu XLPE 1.5 8 0.60 1.50 1.60 1.90 37.15 206010TC2-D-2XISSWYu XLPE 1.5 10 0.60 1.50 2.00 1.90 42.15 267012TC2-D-2XISSWYu XLPE 1.5 12 0.60 1.50 2.00 1.90 43.50 290024TC2-D-2XISSWYu XLPE 1.5 24 0.60 1.70 2.50 2.10 58.45 511536TC2-D-2XISSWYu XLPE 1.5 36 0.60 2.00 2.50 2.40 67.25 681502TC2-E-2XISSWYu XLPE 2.5 2 0.60 1.30 1.60 1.70 27.50 117804TC2-E-2XISSWYu XLPE 2.5 4 0.60 1.40 1.60 1.80 31.45 158708TC2-E-2XISSWYu XLPE 2.5 8 0.60 1.60 2.00 2.00 41.35 278010TC2-E-2XISSWYu XLPE 2.5 10 0.60 1.60 2.00 2.00 46.05 324012TC2-E-2XISSWYu XLPE 2.5 12 0.60 1.60 2.00 2.00 47.40 351824TC2-E-2XISSWYu XLPE 2.5 24 0.60 1.80 2.50 2.20 64.25 632036TC2-E-2XISSWYu XLPE 2.5 36 0.60 2.10 2.50 2.50 73.25 8450

Note: 1.) For Tinned Copper conductor, simply replace “C2” to “T2” of the SCC ITEM CODE. 2.) Other conductor sizes and Pair/Triad counts are available upon request. 3.) Other jacket materials are available upon request. 4.) Standard Cutting length 1000m ± 5%, other lengths are on request.

Page 85: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 84Industrial Cables

CERTIFICATION

Page 86: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 85 Industrial Cables

CERTIFICATION

Page 87: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 86Industrial Cables

Page 88: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 87 Industrial Cables

CERTIFICATION

Page 89: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 88Industrial Cables

Page 90: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 89 Industrial Cables

Page 91: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 90Industrial Cables

CABLE HANDLING AND STORAGE GUIDELINES

The purpose of this document is to provide proper guidelines for transportation, handling and storage of cables and cable reels. Cables not handled properly may lead to damage. Any such damage may alter or degrade the cable characteristics.

K E E P I N G T H E R E E L U P R I G H T :The reel should be handled in upright position with proper stops as shown below.

Proper stops must be fitted to avoid the reels from rolling.

R O L L I N G T H E R E E L S :If reels are to be rolled, they should be rolled in the direction of the arrow on the reel as shown below. Rolling reels in the opposite direction may cause the cable to become loose and cause difficulty in installation. The reel should never be dragged or pushed even for short distances as the flange of the reel may break or get damaged.

L I F T I N G T H E R E E L F O R L O A D I N G / U N L O A D I N G :When lifting the reel from above with a crane or other lifting device, a spreader bar must be used above the reel to prevent inward pressure on the top of the reel flanges. The proper technique is shown below.

Page 92: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 91 Industrial Cables

It should be properly be ensured that the reel is properly hoisted and balanced.

If the reel is lifted by forklift, then approach the reel from the flange side. Position the forks such that the reel is lifted by both reel flanges. Do not allow the lift forks to contact the cable.

T R A N S P O R T A T I O N :During transportation, the reel should be fastened to the base through the center hole or across the flanges with wires or ropes.

To prevent the movement of reels, a combination of wedges/stops and proper support should be used and tied down front and rear as shown below. Reels should never be stacked onto one another.

S T O R A G E :Cable reels should be stored on hard surfaces resting on the flange edge as shown below. The area chosen for storage of cable reels must be level and dry to avoid moisture entry, and protected from sunlight if stored for longer time. A minimum distance of 30cm must be kept between each reel to avoid damage to the cable ends (End Caps). If a portion of the cable is used, the open end of the cable remaining on the reel should immediately be re-sealed in a manner equivalent to the factory seal to prevent the entrance of moisture.

Page 93: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Page 92Industrial Cables

Page 94: INDUSTRIAL CABLES CATALOGUE...2016/03/01  · locations class I and class II division 2 acc. to NEC 501-4(b) and NEC 502-4(b), not allowed for direct connection to low impedance sources,

Head Office

Riyadh

Al-Khobar

Innovation, Commitment, Appreciation, Respect and Excellence W www.saudicable.com

P.O Box 4403, Jeddah 21491

P.O Box 6793, Riyadh 11452

P.O Box 2449, Al-Khobar 31952

T +966 12 608 7666

T +966 11 464 9080

T +966 13 887 5818

F +966 12 608 2864

F +966 11 464 4148

F +966 13 887 5818