INDEX OF DRAWINGSSHTNO. DWG NO. DESCRIPTION
GENERAL
CIVIL
ARCHITECTURAL
STRUCTURAL
HVAC
INDEX OF DRAWINGS (CONT.)SHTNO. DWG NO. DESCRIPTION
PLUMBING
ELECTRICAL
-
··
-
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:07 PM
A-01
Gen
eral
Info
rmat
ion
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
4
DRAWING INDEX
DEFINITIONS
1. GENERAL: BASIC CONTRACT DEFINITIONS ARE INCLUDED IN THE CONDITIONS OF THECONTRACT.
2. "APPROVED": WHEN USED TO CONVEY ARCHITECT'S ACTION ON CONTRACTOR'SSUBMITTALS, APPLICATIONS, AND REQUESTS, "APPROVED" IS LIMITED TO ARCHITECT'SDUTIES AND RESPONSIBILITIES AS STATED IN THE CONDITIONS OF THE CONTRACT.
3. "DIRECTED": A COMMAND OR INSTRUCTION BY ARCHITECT. OTHER TERMS INCLUDING"REQUESTED," "AUTHORIZED," "SELECTED," "REQUIRED," AND "PERMITTED" HAVE THESAME MEANING AS "DIRECTED."
4. "INDICATED": REQUIREMENTS EXPRESSED BY GRAPHIC REPRESENTATIONS OR INWRITTEN FORM ON DRAWINGS, IN SPECIFICATIONS, AND IN OTHER CONTRACTDOCUMENTS. OTHER TERMS INCLUDING "SHOWN," "NOTED," "SCHEDULED," AND"SPECIFIED" HAVE THE SAME MEANING AS "INDICATED."
5. "REGULATIONS": LAWS, ORDINANCES, STATUTES, AND LAWFUL ORDERS ISSUED BYAUTHORITIES HAVING JURISDICTION, AND RULES, CONVENTIONS, AND AGREEMENTSWITHIN THE CONSTRUCTION INDUSTRY THAT CONTROL PERFORMANCE OF THE WORK.
6. "FURNISH": SUPPLY AND DELIVER TO PROJECT SITE, READY FOR UNLOADING,UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS.
7. "INSTALL": UNLOAD, TEMPORARILY STORE, UNPACK, ASSEMBLE, ERECT, PLACE,ANCHOR, APPLY, WORK TO DIMENSION, FINISH, CURE, PROTECT, CLEAN, AND SIMILAROPERATIONS AT PROJECT SITE.
8. "PROVIDE": FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE.
9. "PROJECT SITE": SPACE AVAILABLE FOR PERFORMING CONSTRUCTION ACTIVITIES. THEEXTENT OF PROJECT SITE IS SHOWN ON DRAWINGS AND MAY OR MAY NOT BEIDENTICAL WITH THE DESCRIPTION OF THE LAND ON WHICH PROJECT IS TO BE BUILT.
ABBREVIATIONS
GENERAL NOTES
A. STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS (IF PRESENT) ARESUPPLEMENTAL TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITYOF THE GENERAL CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGSBEFORE THE INSTALLATION OF MECHANICAL OR ELECTRICAL CONSTRUCTION. ANY
DISCREPANCIES BETWEEN THE ARCHITECTURAL AND CONSULTING ENGINEERS'DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION.ANY CONSTRUCTION INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGSSHALL BE CORRECTED BY THE GENERAL CONTRACTOR AT HIS/HER OWN EXPENSE
AND AT NO EXPENSE TO THE OWNER OR ARCHITECT.
B. ALL WORK SHALL COMPLY WITH THE CURRENT ADA ACCESSIBILITY GUIDELINES(AMERICANS WITH DISABILITIES ACT).
C. REFER TO THE CODE COMPLIANCE PLAN FOR APPLICABLE CODES GOVERNING THISWORK. CODE REQUIREMENTS AND REGULATIONS SHALL BE CONSIDERED ASMINIMUM. WHERE THE CONTRACT DOCUMENTS EXCEED (WITHOUT VIOLATING)CODE AND REGULATION REQUIREMENTS, CONTRACT DOCUMENTS SHALL TAKE
PRECEDENCE. IF CONFLICT EXIST, THE MORE STRINGENT SHALL APPLY.
D. THE CONTRACTOR SHALL PROVIDE ADEQUATE BARRICADES AND PROTECTIVEDEVICES SEPARATING CONSTRUCTION AREAS. TEMPORARY PASSAGES SHALL BEPROVIDED AS REQUIRED. PRIOR TO DELIVERY OF MATERIALS TO CONSTRUCTIONZONE AND REMOVAL OF WASTE FROM SITE, THE CONTRACTOR SHALL CHECK WITH
THE OWNER FOR AN ACCEPTABLE ROUTE AND TIME.
E. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER LOCATION AND SIZE OFOPENINGS FOR ALL TRADES AND SHALL COORDINATE ALL CONSTRUCTION ASINDICATED BY THE CONTRACT DOCUMENTS, INCLUDING SHOP DRAWINGSREVIEWED BY THE ARCHITECT.
F. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND NOTIFY THEARCHITECT OF ANY DISCREPANCIES PRIOR TO COMMENCEMENT OF WORK.
G. FOR ALL REMODEL WORK AS OCCURS, THE CONTRACTOR SHALL COORDINATE WITHTHE OWNER ALL MEASURES TO ACCOMPLISH THE WORK WITH THE MINIMUM OFINTERRUPTION TO NORMAL BUILDING PROCEDURES. SYSTEM SHUTDOWNS OF HVAC,PLUMBING, ELECTRICAL, AND NOISY CONSTRUCTION INCLUDING ROTO HAMMER,
SAW CUTTING, CONCRETE ANCHORS, ETC. SHALL BE COORDINATED WITH THEOWNER AT LEAST 72 HOURS PRIOR TO COMMENCEMENT.
H. ALL DIMENSIONS ARE SHOWN TO FACE OF GYPSUM BOARD OF NEWCONSTRUCTION OR STRUCTURAL WALL, UNLESS NOTED OTHERWISE.
I. ALL DRAWINGS, THOUGH NOTED TO SCALE ARE FOR ILLUSTRATION ONLY. THECONTRACTOR SHALL NOT SCALE DRAWINGS.
J. WHEN A DETAIL IS IDENTIFIED AS TYPICAL, THE CONTRACTOR IS TO APPLY THIS DETAILIN ESTIMATING AND CONSTRUCTION TO EVERY LIKE CONDITION WHETHER OR NOTTHE REFERENCE IS REPEATED IN EVERY INSTANCE.
K. DRAWINGS HAVE BEEN DETAILED IN COMPLIANCE WITH U.L. LISTING REQUIREMENTSAND ICBO REPORTS FOR THE MATERIALS SPECIFIED. IF AN ALTERNATE ORSUBSTITUTED MATERIAL IS ACCEPTED AS AN EQUAL BY THE GENERAL CONTRACTOR,HE/SHE WILL ASSUME THE RESPONSIBILITY FOR WHATEVER CONSTRUCTION
MODIFICATION AND/OR ADDITIONAL COSTS ARE REQUIRED.
L. ALL TRASH SHALL BE REMOVED DAILY. BUILDING MATERIALS MAY NOT BE STORED INTHE CORRIDORS AT ANY TIME. BLOCKAGE OF ANY REQUIRED EXIT IS PROHIBITED.
M. ALL PENETRATIONS INTO SOUND OR FIRE RATED PARTITIONS, FLOORS OR CEILINGASSEMBLIES SHALL BE SEALED WITH APPROVED PERMANENT RESILIENT SEALANT.REFER TO IBC CURRENT VERSION FOR REQUIREMENTS FOR OPENINGS IN FIRE RATEDWALLS. FOR OPENINGS LESS THAN 16 SQUARE INCHES, THE SPACE BETWEEN THE
WALL AND ALLOWED PENETRATIONS MUST BE SEALED TO PREVENT THE MOVEMENTOF HOT FLAME OR GASES. ELECTRICAL DEVICES, RECESSED CABINETS, ETC. SHALL BESEALED, LINED, INSULATED OR OTHERWISE TREATED TO MAINTAIN THE INTEGRITY OFTHE ASSEMBLY. SEE PENETRATION DETAILS.
N. ABBREVIATIONS THROUGHOUT THE PLAN ARE THOSE IN COMMON USE. THEARCHITECT SHALL DEFINE THE INTENT OF ANY IN QUESTION.
O. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF WATER AND DRAININSTALLATIONS AND OTHER REQUIRED SERVICES WITH EQUIPMENT MANUFACTURERS.
P. MAINTAIN ALL EXISTING SPRAY-APPLIED FIRE PROOFING ON STEEL STRUCTURALMEMBERS. WHERE EXISTING FIRE PROOFING IS REMOVED FOR INSTALLATION OF NEWBEAMS, INISTRUTS, ETC. THE CONTRACTOR SHALL PATCH AGAIN WITH EQUIVALENTFIRE PROOFING MATERIAL TO MATCH ADJACENT EXISTING MATERIAL.
Q. ALL WOOD CANTS, NAILERS, CURBS, ETC. THROUGHOUT JOB SHALL BE FIRERETARDANT PRESSURE-TREATED, AS PER I.B.C. CURRENT VERSION SEE RELEVANTDETAILS.
R. CONTRACTOR SHALL REFER TO THE PROJECT MANUAL FOR A COMPLETE LIST OFGENERAL CONDITIONS, SPECIAL CONDITIONS AND OTHER NOTES.
VICINITY MAP
NORTHTRUE
SITE
13
00 W
EST
S VALLEY WATER ACCESS
T.O.D. TOP OF DECK
T.O.P. TOP OF PARAPET
TYP. TYPICAL
U
U.N.O. UNLESS NOTED OTHERWISE
V
V. VENT
V.T.R. VENT THROUGH ROOF
VERT. VERTICAL
V.G. VERTICAL GRAIN
VEST. VESTIBULE
V.C.T. VINYL COMPOSITION TILE
V.C.P. VITREOUS CLAY PIPE
W
W.C. WATER CLOSET
W.H. WATER HEATER
W.P. WATER PROOF
W.R. WATER RESISTANT
W.W.F. WELDED WIRE FABRIC
W.F. WIDE FLANGE
WDW. WINDOW
W/ WITH
W/O WITHOUT
WD. WOOD
P
PT. PAINT
PTD. PAINTED
PR. PAIR
PNL. PANEL
d PENNY
P.L. PLASTIC LAMINATE
PL. PLATE
PLBG. PLUMBING
P.S.I. POUND PER SQUARE INCH
P.S.F. POUNDS PER SQUARE FOOT
R
RAD. RADIUS
REC. RECOMMENDATION
REG. REGISTER
REQ'D REQUIRED
R.A. RETURN AIR
REV. REVISION
R.D. ROOF DRAIN
RFG. ROOFING
RM. ROOM
RGH. ROUGH
RND. ROUND
S
SCR. SCREW
SECT. SECTION
SEL. SELECT
SHT. SHEET
SIM. SIMILAR
SLDG. SLIDING
SM. SMOOTH
SPEC. SPECIFICATION
SPL. SPLASH
SQ. SQUARE
S.S. STAINLESS STEEL
STD. STANDARD
STRUC. STRUCTURE
S.A. SUPPLY AIR
SUSP. SUSPENDED
SW.BD. SWITCHBOARD
T
TELCO TELEPHONE COMPANY
T.G. TEMPERED GLASS
T&G TONGUE & GROOVE
T&B TOP & BOTTOM
T.O. TOP OF
T.O.C. TOP OF CURB
H.W. HOT WATER
HR. HOUR
I
IN. INCH
I.D. INSIDE DIAMETER
INSUL. INSULATION
INT. INTERIOR
INV. INVERT
J
JAN. JANITOR
JT. JOINT
JST. JOIST
L
LAM. LAMINATED
LDG. LANDING
LAV. LAVATORY
LT. LIGHT
L.W.C. LIGHT WEIGHT CONCRETE
LVR. LOUVER
M
M.B. MACHINE BOLT
MFR. MANUFACTURER
M.O. MASONRY OPENING
MAT'L MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MTL. METAL
MIN. MINIMUM
MLDG. MOLDING
MULL. MULLION
N
N.G. NATURAL GRADE
NOM. NOMINAL
N/A NOT APPLICABLE
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
O
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F.S. OVERFLOW SCUPPER
O.F.C.I. OWNER FURNISHED, CONTRACTORINSTALLED
DIAG. DIAGONAL
DIA. DIAMETER
DIM. DIMENSION
DISP. DISPENSER
DWL. DOWEL
DN. DOWN
D.S. DOWN SPOUT
D.W.V. DRAINAGE WASTE VENT
DWG. DRAWING
E
EA. EACH
E.W.C. ELEC. WATER COOLER
EL. ELECTRIC
ELEV. ELEVATION
EQ. EQUAL
EQUIP. EQUIPMENT
EXH. EXHAUST
EXIST. EXISTING
E.J. EXPANSION JOINT
EXT. EXTERIOR
F
FT. FEET
FIN. FINISH(ED)
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
FIXT. FIXTURE
FL. FLASHING
G
GALV. GALVANIZED
GA. GAUGE
G.C. GENERAL CONTRACTOR
G.S.N. GENERAL STRUCTURAL NOTES
GL. GLASS
GD. GRADE
GRL. GRILLE
GRD. GROUND
GYP. GYPSUM
H
HDW. HARDWARE
HDWD. HARDWOOD
HTR. HEATER
HT. HEIGHT
H.P. HIGH POINT
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
H.B. HOSE BIB
& AND
@ AT
Ø DIAMETER
(E), EXIST. EXISTING
(N) NEW
d PENNY
# POUND OR NUMBER
A
AC ACOUSTIC
ADD ADDENDUM
A/C AIR CONDITIONING
ALT. ALTERNATE
AL ALUMINUM
A.B. ANCHOR BOLT
ARCH ARCHITECT(URAL)
ASP. ASPHALT
B
BSMT. BASEMENT
B.M. BENCHMARK
BLKG. BLOCKING
BD. BOARD
B.O. BOTTOM OF
BLDG. BUILDING
C
CAB'T CABINET
C.I.P. CAST IN PLACE
C.B. CATCH BASIN
CLG. CEILING
CL CENTER LINE
C.T. CERAMIC TILE
CH CHANNEL
C.O. CLEAN OUT
CLR. CLEAR
CL. CLOSET
COL. COLUMN
CONC. CONCRETE
CMU CONCRETE MASONRY UNIT
COND. CONDITION
CONN. CONNECTION
CONST. CONSTRUCTION
CONT CONTINUOUS
CJ CONTROL JOINT
D
D.P. DAMP PROOFING
D.B. DECK BEARING
ARCHITECTURALA-01 General Information
A-02 General Information
A-03 American National Standard Institute Requirements
A-04 General Legend & Notes
A-10 Code Compliance Plan Level 1 Overall
A-11 Floor & Ceiling Demolition Plan
A-11A Enlarged Floor Demolition Plan
A-12 Floor Plan & Reflected Ceiling Plan
A-13 Roof Plan
A-14 Enlarged Plans
A-15 Enlarged Plans
A-16 Enlarged Plans
A-21 Exterior Elevations
A-31 Interior Elevations
A-32 Interior Elevations
A-33 Interior Elevations
A-34 Interior Elevations
A-41 Building Sections
A-42 Wall Sections
A-51 Door Schedule
A-52 Window Schedule
A-53 Finish Schedule
ARCHITECTURAL DETAILSGA-01 Wall Types and Details
GA-02 Details
GA-03 Details
GA-04 Details
GA-05 Cabinet Legend & Details
GA-06 Details
GA-07 Details
GA-08 Details
GA-09 Details
NORTH
PROJECT
-
Concrete
Earth
Gypsum
Board
Insulation
Rigid
Masonry
Brick
Masonry
Concrete
Block
Finish Wood
EIFS
Stone
Precast
Steel
Gravel
Batt
Insulation
Blocking
HATCH PATTERN BELOW INDICATES REPRESENTATION OF BUILDING MATERIALS IN
BUILDING SECTIONS, WALL SECTIONS AND DETAILS.
A2022
4
1
2
3
A252
1
CLOUD INDICATES
DRAWING
REVISION AREA
ROOM NAME
ROOM NUMBER
SHEET WHERE DRAWN
BUILDING SECTION
EXTERIOR ELEVATION
NUMBER
REVISION NUMBER
INTERIOR ELEVATION
NUMBER
SHEET WHERE DRAWN
SHEET WHERE DRAWN
DETAIL NUMBER
SHEET WHERE
DRAWN
0B
CL
FLOOR FINISH TAG
TAGS ARE INDICATED ON FINISH FLOOR PLAN.
SEE FINISH SCHEDULE, SHEET A-53, FOR FLOOR
COVERING AND FINISHES REQUIRED.
CENTER LINE
0A
01
02DATUM POINT TAG
32
00.00
W14
DETAIL KEYED NOTES
GENERIC, NON PROJECT SPECIFIC
NOTES
/
MATCHLINE
3 A101
FLOOR PLAN MATCHLINE
BUILDING SECTIONS
SECTION TAGS ARE
INDICATED ON
OVERALL DIMENSION
FLOOR PLANS
WALL SECTIONS
SECTION TAGS ARE
INDICATED ON
DIMENSION FLOOR
PLANS
EXTERIOR ELEVATION TAGS
TAGS ARE INDICATED ON
OVERALL DIMENSION
FLOOR PLANS
INTERIOR ELEVATION TAGS
TAGS ARE INDICATED ON
FINISH FLOOR PLANS
WALL TAG
WALL TAGS ARE INDICATED ON
DIMENSION FLOOR PLANS. WALL
TYPES ARE INDICATED IN SHEET GA-01
NORTH
A506
1
A506
1
A
A1
FLOW ARROW
WATER DRAINAGE DIRECTION
SHOWN ON SITE AND ROOF
PLANS
CABINET TAG
CABINET TYPES ARE INDICATED ON
INTERIOR ELEVATIONS & CABINET LEGEND,
SHEET A-05.
DIVISION NOTE
DIVISON #
0000
ROOM
100'-0"
VERTICAL ELEVATION
SPOT ELEVATION
ELEVATION
LEVEL
T.O.W.
9'-0"
HEIGHT ABOVE FINISH FLOOR
ROOM AREA
101A
F2
2
A101
KEYED NOTES
PROJECT SPECIFIC NOTES
INDICATED ON PLANS,
SECTIONS AND ELEVATIONS.
WALL BASE TAG
TAGS ARE INDICATED ON FINISH FLOOR PLAN.
SEE FINISH SCHEDULE, SHEET A-53, FOR WALL
BASE TYPE.
WALL FINISH TAG
TAGS ARE INDICATED ON FINISH FLOOR PLAN.
SEE FINISH SCHEDULE, SHEET A-53, FOR WALL
FINISHES REQUIRED.
B1
W3
P2
WINDOW TAG
WINDOWS TAGS ARE INDICATED ON
DIMENSION FLOOR PLANS
DOOR TAG
DOOR TAGS ARE INDICATED ON
DIMENSION FLOOR PLANS
2
A101
2
A101
SHEET WHERE DRAWN
WALL SECTION
SHEET WHERE DRAWN
DETAIL NUMBER
SIGN TAG
TAGS ARE INDICATED ON FINISH FLOOR PLAN.
SEE SIGN TYPE DETAILS.
S2
PAINT FINISH TAG
TAGS ARE INDICATED ON FINISH FLOOR PLAN.
SEE FINISH SCHEDULE, SHEET A-53, FOR PAINT
FINISHES REQUIRED.
GRID LINE
GRID TAG
NORTH ARROW
DETAIL TAGS
DETAIL TAGS
CEILING TAG
ROOM TAG
REVISION TAG
GRID REFERENCE MARK
SHEET WHERE DRAWN
DETAIL LOCATION NUMBER
ROOM NAME
SQUARE FEETROOM
A-C 999
OCCUPANCY TYPE
CODE COMPLIANCE PLAN
ROOM TAG
EXIT TAG
OCCUPANT LOAD
NAME
OCCUPANT LOAD
AT EXIT
OCCUPANT LOAD
ALLOWED
EGRESS WIDTH
PROVIDED
EXIT
100 36"
000
999
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:08 PM
A-02
Gen
eral
Info
rmat
ion
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
5
LEGEND - MATERIALS GENERAL INFORMATION SYMBOLS & TAGS
-
MANEUVERING CLEARANCE AT SWINGING DOORS
(B) FRONT APPROACH, PUSH SIDE (C) HINGE APPROACH, PULL SIDE (D) HINGE APPROACH, PULL SIDE
FIG. 404.2.4.1(E) HINGE APPROACH, PUSH SIDE (G) LATCH APPROACH, PUSH SIDE(F) LATCH APPROACH, PULL SIDE
(445) (305)(915) (1065)
(610)
(1370)
(1065)
(1370)
(1525)
(1065)
(1220)
(1220)
(610)
FIG. 404.2.4.2
MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS
(A) FRONT APPROACH (B) POCKET OR HINGE APPROACH (C) STOP OR LATCH APPROACH
FIG. 404.2.6
TWO DOORS IN A SERIES
(A) (B)
(1220)
(1065)
(1065)
(610)
(1370)(1220) (1220)
(A) CIRCULAR (B) T-SHAPED
(A) FORWARD (B) PARALLEL
FIG. 304.3
SIZE OF WHEELCHAIR TURNING SPACE
FIG. 405.5
POSITION OF CLEAR FLOOR OR GROUND SPACE
(1525) (1525)
(305) (915) (305)
(760) (1220)
(915)
(1525)
(760)
(1220)
(A) FORWARD APPROACH (B) PARALLEL APPROACH
FIG. 305.7
MANEUVERING CLEARANCE IN AN ALCOVE
(915) (1525)
(1220)
(760)
(X >
610)
(X >
380)
FIG. 702.3.3.1
LOCATION OF WALL-MOUNTED APPLIANCES
(A) WALL ALARM (B) WALL ALARM WITH SMOKE DETECTOR
FLOOR OR GROUND
(100-3
05)
(2030-2
440)
FLOOR OR GROUND
(2030-2
440)
(CEIL
ING
HEIG
HT
> 9
140)CEILING CEILING
FIG. 702.3.3.2
LOCATION OF CEILING-MOUNTED APPLIANCES
FIG. 702.3.5.1
APPLIANCE SPACING IN CORRIDORS
(15-3
0m
)
(4570) (4570)(15-30m) (15-30m)
FIG. 702.3.6.2
APPLIANCE LOCATION IN
SLEEPING ROOMS
(A) ONE BED
(4880)
(B) TWO BEDS
FIG. 703.2.4.4
CHARACTER HEIGHT
LIBRARY
(16-5
1)
FIG. 703.2.8
MOUNTING LOCATION AT DOORS
(455)
(455)
(A) PARALLEL APPROACH
(B) FORWARD APPROACH
FIG. 704.2.1
CLEAR FLOOR OR GROUND
SPACE FOR TELEPHONES
FIG. 705.3.1.1
TRUNCATED DOME SIZE
(60)
FIG. 306.3
KNEE CLEARANCE
(205)
(280)
(685)
(230)
FIG. 306.2
TOE CLEARANCE
(430)
(230)
FIG. 403.5.1
CLEAR WIDTH AT TURN
(1065)
(1065)
(X <
1220)
(610) (610)(1220)
(815)
(915)
(815)
90
(A) HINGED DOOR
(815)
(B) SLIDING DOOR
(815)
(C) FOLDING DOOR
FIG. 404.2.3
CLEAR WIDTH OF DOORWAYS
(1220)
(A) FRONT APPROACH, PULL SIDE
BUILDING BLOCKS
MA
X.
(6.4
)
2
FIG. 303.2VERTICAL CHANGES IN LEVEL
FIG. 303.3
BEVELED CHANGES IN LEVEL
1
FIG. 302.3
OPENINGS IN FLOOR
OR GROUND SURFACES
PROTRUDING OBJECTS
FIG. 307.3
POST-MOUNTED PROTRUDING OBJECTS
(100)
(305) (305)
(X > 305)
(X > 305)
FIG. 307.2
LIMITS OF PROTRUDING OBJECTS
(380)
(1220)
FIG. 308.2.1
UNOBSTRUCTED FORWARD REACH
FIG. 308.2.2
OBSTRUCTED HIGH FORWARD REACH
(1220)
(510) (510-635)
(1220)
(1220)
(255)
FIG. 308.3.1
UNOBSTRUCTED SIDE REACH
FIG. 308.3.2
OBSTRUCTED HIGH SIDE REACH
(610)
FIG. 403.5
CLEAR WIDTH OF AN ACCESSIBLE ROUTE
LONG DIMENSION
PERPENDICULAR
TO DIRECTION OF TRAVEL
(1170)
(4570)
(4880)
(13)
CL
DOORS AND DOORWAYS
18" MIN.
48"
MIN
. 36" MIN.
60"
MIN
.
42" MIN.
54"
MIN
.
42"
MIN
.
54" MIN.
48"
MIN
.
24" MIN.12" MIN.24" MIN.
42"
MIN
48" MIN. 48" MIN. 54" MIN.
48"
MIN
.
42"M
IN.
42"
MIN
.
24" MIN.
CLEAR FLOOR SPACE
60" MIN. 60" MIN.
60"
MIN
.
48" MIN.
48"
MIN
.
30" MIN.
30"
MIN
.
36"
MIN
.
12" MIN. 36" MIN. 12" MIN.
48"
MIN
.
36" MIN. 60" MIN.
30"
MIN
.
X >
15"
X >
24"
4"-
12"
80"-
96"
30' M
AX
.
CEIL
ING
HEIG
HT
> 3
0'
15' MAX. 50'-100' 50'-100' 15' MAX.
50'-100'
15' M
AX
.
16' MAX.
16' MAX.
5/8
"-2"
18" MIN.
18"
20"
MA
X.
10"
MA
X.
(255) (
510) .9" 2.3
5"2.35"
(60)
(23)
.2"
(5)
27"
MIN
.
9"
MIN
.
8" MIN.
11" MIN.
9"
MIN
.17" MIN.
42"
MIN
.42"
MIN
.
48" MIN.
X <
48"
36"
MIN
.
32"
MIN
.
24" MAX.48" MIN.24" MAX.
32" MIN.32" MIN.
32" MIN.
1/4
"1/4
" -
1/2
"
(6.4
-13)
4" MAX.
X >
80"
X >
27"
X >
27" 80"
MIN
.
27"
MA
X.
X > 12"
X > 12"
(X >
2030)
(X >
685)
(X >
685)
(685)
12" MAX 12" MAX
REACH RANGES
15"
MIN
.
48"
MA
X.
48"
MA
X.
20" MAX.
44"
MA
X.
(1120)
20" - 25"
48"
MA
X.
48"
MA
X.
10" MAX.
46"
MA
X.
24" MAX.
ACCESSIBLE ROUTES
COMMUNICATION ELEMENTS AND FEATURES
1/2
" M
AX
.
(2030)
__
(15
25
)
60
" M
IN
TYPICAL MOUNTING HEIGHTS
PAPER TOWEL
DISPENSER
FIRE EXTINGUISHER
CABINET
CENTERLINE OF
OPERABLE
PARTS
4' -
0"
FLOOR LINE
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:11 PM
A-03
Am
eric
an N
atio
nal S
tand
ard
Inst
itute
Req
uire
men
ts
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
6SCALE: 3/16" = 1'-0"
American National Standard Institute (ICC A117.1 - 2009) Requirements1
-
ROOF DRAIN. SEE DETAIL
TAPERED INSULATION CRICKET WITH 1/8" PER
FOOT SLOPE, MINIMUM, ALONG VALLEY
AND 1/4" PER FOOT SLOPE, MINIMUM,
ACROSS CRICKET.
SLOPE DOWN DIRECTION FOR WATER
FLOW TOWARD ROOF DRAINS.
ROOF HATCH
WALKWAY PADS.
AS ROOF STRUCTURE IS LEVEL (FLAT WITH NO
SLOPE) IN THIS AREA, USE TAPERED INSULATION
(1/4" PER FOOT SLOPE) FOR DRAINAGE.
PROVIDE CRICKETS AS REQUIRED ON THE TOP
OF TAPERED INSULATION.
BUILDING COMPONENTS (ROOF DRAINS, HATCH, ETC.) ARE DRAWN AT 1/4" = 1' - 0".
ON PLANS DRAWN AT 1/8" = 1' - 0" SCALE, COMPONENTS SHALL APPEAR HALF THIS
SIZE.
2' X 2' LAY-IN ACOUSTICAL PANEL
CEILING. SEE DETAILS
CEILING HEIGHT ABOVE FINISHED FLOOR
NEW RETURN AIR GRILLE - SEE MECHANICAL
DRAWINGS
9'-0"
BUILDING COMPONENTS (CEILING, LIGHT FIXTURES, ETC) INDICATED BELOW IN
THIS LEGEND ARE DRAWN AT 1/4" = 1'-0" SCALE. COMPONENTS SHALL APPEAR
HALF THE SIZE (SMALLER) ON PLANS DRAWN AT 1/8" = 1'-0" SCALE.
2' X 4' LAY-IN ACOUSTICAL PANEL CEILING.
SEE DETAILS
SUSPENDED GYPSUM BOARD CEILING OR
SOFFIT SEE DETAILS
NEW SUPPLY AIR GRILLE - SEE MECHANICAL
DRAWINGS
NEW EXHAUST FAN - SEE MECHANICAL
DRAWINGS
NEW 2' X 4' LIGHT FIXTURE - SEE ELECTRICAL
DRAWINGS
,
,
NEW WALL MOUNTED LIGHT - SEE
ELECTRICAL DRAWINGS
NEW DOOR IN NEW WALL. SEE DOOR
SCHEDULE.
NEW WINDOW. SEE WINDOW TYPES.
TAGS ARE PLACED ON THE FRONT
SIDE OF WINDOW.
NEW CMU WALL. SEE WALL TAGS ON
DIMENSION PLANS FOR MORE
INFORMATION.
NEW CAST-IN-PLACE CONCRETE
WALL. SEE WALL TAGS ON DIMENSION
PLANS FOR MORE INFORMATION.
NEW BRICK MASONRY WALL. SEE
WALL TAGS ON DIMENSION PLANS
FOR MORE INFORMATION.
NEW METAL STUD WALL. SEE WALL
TAGS ON DIMENSION PLANS FOR
MORE INFORMATION.
BUILDING COMPONENTS (DOORS, WALLS, ETC) INDICATED BELOW IN THIS LEGEND
ARE DRAWN AT 1/4" = 1'-0" SCALE. COMPONENTS SHALL APPEAR HALF THE SIZE
(SMALLER) ON PLANS DRAWN AT 1/8" = 1'-0" SCALE.
A1
A
101
EXISTING DOOR TO REMAIN
EXISTING DOOR TO BE DEMOLISHED
EXISTING WINDOW TO REMAIN
EXISTING WINDOW TO BE
DEMOLISHED
EXISTING WALL TO REMAIN
EXISTING WALL TO BE DEMOLISHED.
BUILDING COMPONENTS (DOORS, WALLS, ETC) INDICATED BELOW IN THIS LEGEND
ARE DRAWN AT 1/4" = 1'-0" SCALE. COMPONENTS SHALL APPEAR HALF THE SIZE
(SMALLER) ON PLANS DRAWN AT 1/8" = 1'-0" SCALE.
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:14 PM
A-04
Gen
eral
Leg
end
& N
otes
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
7
GENERAL NOTES - FLOOR & DIM. PLANS
A. REFER TO THE CODE COMPLIANCE PLANS FOR INDICATION OF FIRE RATED WALLS.
B. AT LOCATIONS WITHOUT CEILINGS (ROOM IS OPEN TO STRUCTURE ABOVE), EXTENDALL WALLS, SOFFITS, AND HEADERS (INCLUDING ALL STUD FRAMING, GYPSUMBOARD, INSULATION & CMU, WHERE APPLICABLE) TO THE METAL ROOF DECKABOVE.
C. WHEN FLOOR HEIGHT VARIES IN A ROOM, THE CEILING HEIGHT SHOWN IS THE HEIGHTABOVE THE FLOOR AT THE ENTRY, UNO.
D. FOR CLARITY SAKE, DIMENSIONS ARE NOT SHOWN AT THE FOLLOWING LOCATIONS: a. WHERE THE FACE OF WALL COINCIDES WITH THE MAIN GRID LINE OR 4'-0" X 4'-0"SUBGRID. b. WHERE THE CENTER OF WALL COINCIDES WITH THE MAIN GRID LINE OR 4'-0" X 4'-0"
SUBGRID.
E. VERIFY WITH ARCHITECT FOR DIMENSIONS NOT SHOWN.
F. SEE STRUCTURAL DRAWINGS FOR CMU WALLS, MASONRY COLUMNS, AND MASONRYBEAMS. SEE BUILDING EXTERIOR ELEVATIONS FOR VENEER TYPES. SEE FINISH SCHEDULEFOR CMU THAT IS HONED, SCORED, SEALED, PAINTED, ETC.
G. SEE CIVIL, PLUMBING, AND MECHANICAL DRAWINGS FOR FLOOR SINKS, FLOORDRAINS, AND OPENINGS IN FLOOR SLABS AND ROOFS FOR DUCTWORK, ETC.
H. SEE DOOR AND WINDOW SCHEDULE FOR THE REQUIRED DOOR AND WINDOWOPENING SIZES
I. SEE FINISH SCHEDULE AND STRUCTURAL DRAWINGS AND PROVIDE RECESS INCONCRETE FLOOR SLAB AS REQUIRED TO ACCOMODATE FLOOR FINISHES.CONCRETE FLOOR SLAB THAT IS ON GRADE, SHALL BE RECESSED AS REQUIRED, FORA THICK SET MORTAR FOR CERAMIC TILE FINISH. SLOPE SHALL BE AT 1/8" PER FOOT
TOWARDS THE FLOOR DRAIN. CONCRETE FLOOR SLAB, THAT IS NOT ON GRADE,NEED NOT BE RECESSED. IN SUCH LOCATION, USE THIN SET MORTAR FOR CERAMICTILE FINISH WITH A GENTLE SLOPE TOWARDS DRAIN.
J. ALL PENETRATIONS (PIPES, CONDUITS, JOISTS, ETC.) THROUGH FIRE RATED BARRIERWALLS SHALL BE SEALED COMPLETELY WITH FIRE RATED SEALANTS. FILL GAP BETWEENFLUTES OF THE METAL DECK AND METAL TRACK TOP RUNNER WITH FIRE RATEDSEALANTS. SEAL TIGHTLY AROUND PIPES, CONDUITS, DUCTS, ETC THAT PENETRATES
THE FIRE BARRIER WALL WITH FIRE RATED SEALANTS. APPLY SEALANT AS PERMANUFACTURERS RECOMMENDATIONS WITH ANY ADDITIONAL MATERIAL ASREQUIRED INSTALLED AROUND PENETRATIONS TO MAINTAIN THE INTEGRITY OF THEFIRE WALL. SEE MECHANICAL DRAWINGS FOR FIRE AND SMOKE DAMPERS.
K. WALL CABINETS HAVE A DEPTH OF 1'-3" UNLESS NOTED OTHERWISE.
L. ALL MASONRY MORTAR JOINTS LOCATED INSIDE THE BUILDING SHALL BE TOOLEDJOINTS, UNLESS NOTED OTHERWISE. MASONRY JOINTS ON THE BUILDING EXTERIORSIDE SHALL MATCH EXISTING JOINTS.
M. SEE OVERALL FLOOR PLAN SHEETS FOR ANGLES, PIVOT POINT AND DIMENSIONSBETWEEN GRID LINES.
N. SEE CODE COMPLIANCE FLOOR PLANS FOR LOCATION OF FIRE BARRIER, NONRATED WALLS, ETC.
O. SEE ENLARGED FLOOR PLANS FOR ADDITIONAL DIMENSIONS.
P. IN SOME PROJECTS, DUE TO THE LARGE BUILDING FOOTPRINT SIZE, FLOOR PLANS ARESPLIT AS AREAS A, B, C, ETC. AND EACH AREA IS INDICATED ON SEPARATE SHEETS.MATCH LINES INDICATE THE BOUNDARIES OF EACH AREA. WHEN CONTRACTORS AREPREPARING BID FOR THE PROJECT, COST SHALL INCLUDE ONLY THE BUILDING
ELEMENTS AND ASSOCIATED CONSTRUCTION WORK CALLED OUT WITH KEYED NOTESIN THE AREA INDICATED ON THE SHEET. KEYED NOTES INDICATED OUTSIDE THE MATCHLINE IN ADJACENT FLOOR AREAS SHALL NOT BE COUNTED FOR THAT AREA. THISAVOIDS DUPLICATION OF BUILDING ELEMENTS AND CONSTRUCTION WORK.
GENERAL NOTES - REFLECTED CEILING PLAN
A. SEE MECHANICAL DRAWINGS FOR DIFFUSER LOCATIONS IN CEILING. CONTRACTORSHALL COORDINATE WITH LIGHT FIXTURES (AS INDICATED IN ELECTRICAL DRAWINGS)AND MOVE DIFFUSERS AROUND THE LIGHT FIXTURE IF THERE IS ANY CONFLICTBETWEEN THE TWO.
B. SOME OF THE ITEMS ON CEILING INDICATED IN MECHANICAL AND ELECTRICALDRAWINGS, MAY OR MAY NOT BE INDICATED ON ARCHITECTURAL CEILING PLANS.SEE MECHANICAL AND ELECTRICAL DRAWINGS AND COORDINATE WITH ARCHITECTFOR ANY REQUIRED CLARIFICATIONS.
C. CONTRACTOR SHALL NOT HANG CEILING TILES AND LIGHTS FROM DUCTS. FORAREAS ABOVE THE CILING WHERE OVERSIZE DUCTS OCCUR SEE DETAIL 4/GA-07.
D. PAINT ALL VISIBLE EXPOSED ITEMS LIKE METAL DECK, STEEL ANGLES, STEEL BEAMS,STEEL TRUSSES, MISCELLANEOUS EXPOSED STEEL STRUCTURAL COMPONENTS,HOLLOW METAL DOORS, DOOR FRAMES & WINDOW FRAMES. PAINT EXPOSEDSURFACES (WITH COLORS AND ACCENT COLORS AS SELECTED BY ARCHITECT)
EXCEPT WHERE NATURAL FINISH OR MATERIAL IS SPECIFICALLY NOTED AS A SURFACENOT TO BE PAINTED. DO NOT PAINT CONCEALED SURFACES, FINISHED METALSURFACES, OPERATING PARTS AND PRE FINISHED ITEMS.
GENERAL NOTES - ROOF PLAN
A. PROVIDE CRICKET ON THE HIGH SIDE OF ROOF AT ALL CURB LOCATIONS FORMECHANICAL EQUIPMENT, SKYLIGHT, ROOF HATCH, ETC. WHETHER INDICATED ONTHE ROOF PLAN OR NOT.
B. PROVIDE WEATHERHEAD (GOOSNECK 2" CONDUIT) WHERE CONDUCTORSPENETRATE ROOF FOR DISCONNECT SWITCHES, POWER OUTLETS, ETC. SECUREGOOSNECK TO STRUCTURE BELOW.
C. PROVIDE WALKWAY PADS BETWEEN MECHANICAL EQUIPMENT, TO AND FROM ROOFHATCHES AND OTHER ROOF ACCESS POINTS, AND AROUND MECHANICALEQUIPMENT REQUIRING PERIODIC MAINTENANCE.
A. CONTRACTOR SHALL VERIFY ALL EXISTING SITE AND BUILDING CONDITIONSINCLUDING UNDERGROUND UTILITIES AND SERVICE LINES, IRRIGATION LINES AND SUBSURFACE STRUCTURES AND ALL OTHER EXISTING CONSTRUCTION BOTH ABOVE ANDBELOW GRADE.
B. PRIOR TO REMOVAL OF EXISTING BUILDING MATERIALS (INCLUDING WALLS, DOORS,WINDOWS, CEILING, ETC.) INDICATED IN THE DEMOLITION PLANS, CONTRACTORSHALL THOROUGHLY COORDINATE ARCHITECTURAL FLOOR PLANS, CEILING PLANS,FINISH SCHEDULES AND ALL CONSULTANT DRAWINGS TO DETERMINE EXACT EXTENT
OF REMOVAL.
C. COORDINATE WITH OWNER'S REPRESENTATIVE REGARDING ITEMS SHOWN TO BEREMOVED THAT WILL BECOME PROPERTY OF THE OWNER. CAREFULLY REMOVE SUCHITEMS SO AS NOT TO DAMAGE THEM.
D. IN EXISTING WALLS THAT ARE NOTED TO REMAIN, ANY NAILS, SCREWS, OR OPENINGSTHAT REMAIN AS A RESULT OF EXISTING EQUIPMENT REMOVAL OR WALL REMOVALSHALL BE PATCHED WITH SMOOTH, EVEN, INVISIBLE TRANSITION. IN PLACES WHERETHE EXISTING WALL IS CUT FOR INSTALLATION OF POWER OUTLETS, SWITCH,
THERMOSTAT, ETC. PATCH OPENING IN WALL WITH GYPSUM BOARD. PROVIDESMOOTH, EVEN, INVISIBLE TRANSITION BETWEEN NEW AND EXISTING WALL FINISH.
E. THE OWNERS STAFF WILL CONTINUE TO OCCUPY AREAS DIRECTLY ADJACENT TO THECONSTRUCTION AREA. THE CONTRACTOR AND SUB-CONTRACTORS SHALL TAKE ALLNECESSARY MEASURES TO MINIMIZE DISRUPTION ACTIVITIES CONDUCTED BY THEOWNERS STAFF. THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE OF
NOISY ACTIVITIES, SHUT-DOWNS, AND ANY OTHER ACTIVITIES WHICH MAY DISRUPTNORMAL OPERATIONS PRIOR TO PERFORMING THE WORK.
F. ONCE FLOORING DEMOLITION HAS OCCURRED, CLEAN AND PREPARE FLOOR TORECEIVE NEW FLOOR COVERINGS. THIS SHALL BE COORDINATED WITH THE FINISHSCHEDULE AND MANUFACTURER OF NEW PRODUCTS FOR FLOOR PREPARATIONREQUIREMENTS.
G. ITEMS SHOWN ON THESE FLOOR PLANS FOR REMOVAL ARE BUILT-IN ITEMS.EQUIPMENT, FURNITURE, & OTHER ITEMS EXISTING IN THE SPACE THAT ARE NOTBUILT-IN SHALL BE REMOVED OR CLEARED TEMPORARILY BY THE OWNER.
GENERAL NOTES - DEMOLITION FLOOR PLAN
LEGEND - ROOF PLAN LEGEND - FLOOR & DIMENSION PLANSLEGEND - REFLECTED CEILING PLAN LEGEND - DEMOLITION FLOOR PLAN
-
SB SBSB SB SB
SP SPSP SP SP
O.L. 3
LEGEND DESCRIPTION FIRE RESISTANCE RATINGDOOR FIRERATING
WINDOW FIRERATING
AREA OF REMODEL N/A N/A N/A
PATH OF TRAVEL N/A N/A N/A
1-HOUR FIRE RATED 1-HOUR FIRE RESISTANCE 3/4-HOUR 3/4-HOUR
2-HOUR FIRE RATED 2-HOUR FIRE RESISTANCE 1 1/2-HOUR 1 1/2-HOUR
SMOKE BARRIER WALL 1-HOUR FIRE RESISTANCE 1/3-HOUR 3/4-HOUR
SMOKE PARTITION WALL 0-HOUR FIRE RESISTANCE SMOKE SMOKE
FIRE EXTINGUISHER & CABINET N/A N/A N/A
OCCUPANT LOAD N/A N/A N/A
F.E.C.
EXIT SIGN N/A N/A N/A
FIRE RESISTANCE RATING FOR BUILDING ELEMENTS (TABLE 601)
Required Provided
Structural Frame: 0 0
Bearing Walls:
Exterior 0 0
Interior 0 0
Non-Bearing Walls:
Exterior 0 0
Interior 0 0
Floor Construction 0 0
Roof Construction 0 0
International Building Code (IBC) 2015
International Fire Code (IFC) 2015
International Mechanical Code (IMC) 2015
International Plumbing Code (IPC) 2015
ANSI/ASHRAE/IES Standard 90.1 2010
National Electric Code (NEC) 2014
NFPA 101 2015
ANSI 117.1 2009
APPLICABLE CODES
OCCUPANCY : B (Business)
CONSTRUCTION TYPE : Type V-B
OTHER CODE REQUIREMENTS
Travel Distance : 300 Feet (B)
Common Path of Travel : 100 Feet (B)
Roof Covering Classification : A
OCCUPANT LOADS:
Business : 100 Sq. Ft. Gross per Occupant
Occupant Load (New Addition) : 15 Occupants
Occupant Load (Existing Building) : 139 OccupantsTotal Occupant Load (Per Code) : 154 Occupants
Egress width required : 36"
Egress width provided : 324"
NUMBER OF STORIES
Allowable Stories : 2
Actual Stories : 1
BUILDING HEIGHT
Allowable Height : 40 ft.
Actual Height : 15' - 4"
BUILDING AREA
Allowable Area (per floor):
Aa = At + (Ns x If)
Aa = 9,000 + (9,000 x .75)
Aa = 9,000 + 6,750
Aa = 15,750 sf.
Area Increase due to Frontage:
If=(F/P - 0.25)W/30
If=(694/694 - 0.25) x 30/30*
If = (1 - 0.25) x 1
If = 0.75 x 1
If = 0.75
*W = 30
Actual Area (per floor)
Level 1 : 13,921 sf.
Addition : 1,466 sf.Actual Area (Total) : 15,383 sf.Allowable Area : 15,750 sf.
PLUMBING FIXTURES
Existing:
Water Closets : (3) Male (3) Female
Urinals : (3)
Lavatories : (3) Male (5) Female
Drinking Fountains : (2)
Service Sinks : (1)
Showers : (5) Male (1) Female
Required:
Water Closets : (5)
Urinals : (0)
Lavatories : (3)
Drinking Fountains : (2)
Service Sinks : (1)
Showers : (0)
EXIT
180 36"
23
383 SF
STORAGE
B 5
230 SF
WET LAB
B 3289 SF
B.O.D. LAB
B 3
214 SF
MICRO LAB
B 3
59 SF
STORAGE
B 1
914 SF
MAIN LAB
B 10
156 SF
ANALYST
OFFICE/FUTURE
METALS LAB
B 2
156 SF
NUTRIENTS
B 2
197 SF
OFFICE
B 2
138 SF
CUBBIES
B 2
252 SF
SEMI-VOLATILES
B 3
160 SF
VOLATILES
B 2
EXIT
180 36"
8
GAS
D.I. TANKS
EXIT
180 36"
8TRAVEL
DISTANCE:
42 FEET
TRAVEL
DISTANCE:
74 FEET
TRAVEL
DISTANCE:
53 FEET
8
10
A C
2
7
4
3
1
B
9
AREA OF REMODEL
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:16 PM
A-10
Cod
e C
ompl
ianc
e P
lan
Leve
l 1O
vera
ll
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
8
NORTH
CODE REVIEWLEGEND
SCALE: 1/8" = 1'-0"1Code Compliance Plan - Level 1 Overall
KEY PLAN
-
5' -
0"
8' - 10 1/2" F.V.
2' - 6" 6' - 8 1/2"12' - 0 3/8" 3' - 4"
02.12
02.11
CO
NSTR
UC
TIO
N L
IMIT
LIN
E
02.0202.0202.0202.0202.0202.02
02.0202.02
02.0202.0202.02
02.0202.02
02.02
02.0202.02
02.02
02.02
02.0202.02
02.02
02.02
02.0202.02
02.05
02.40
02.05
02.05
02.4002.40
02.07
02.07
02.09
02.09
02.09 02.09
02.1002.1002.10
02.10
02.10
02.13
02.13
02.13
02.13
02.14
02.14 02.14
02.1502.15
02.1502.15
02.1502.1502.15
02.15
TYP02.1502.15
02.1502.15
02.1502.1502.1502.15
02.1502.15
TYP02.15
02.16
02.16
02.16 02.16
02.10
02.16
02.1702.1702.1702.17 02.1702.1702.1702.17
02.1702.17
02.17
02.17
02.1702.17
02.1802.18
TYP02.18
02.19
02.20 02.20
02.20
02.20
02.2002.20
02.25
02.25
02.25
02.21
02.26
02.26
02.2302.23
02.22
02.2102.21 02.24
02.25
02.0602.06
02.34
CONSTRUCTION LIMIT LINE
02.40
02.05
02.0502.05
02.05
02.40
02.18
02.15
02.1502.15
02.05
02.05
02.22
02.22
CONSTRUCTION LIMIT LINE
02.22
02.22
02.2202.22
02.3902.39
02.2202.2202.22
02.06
02.38
02.06
02.23
02.05
02.40
02.15
02.15
02.15
02.16
02.1802.1802.1802.1802.1802.18
02.1502.1502.17
02.1802.18
8
10
A C
2
7
4
3
1
B
9
02.28
02.03
CO
NSTR
UC
TIO
N L
IMIT
LIN
E
02.27
TYP02.29
02.31
02.27
TYP02.29
TYP02.31
02.27
02.27
02.27
02.2702.27
TYP02.29
TYP02.29
TYP02.29
TYP02.29
TYP02.29
02.31
TYP02.31
02.3102.3102.31
TYP02.30
02.33
TYP02.30
02.33
FIELD VERIFY
8' - 0" MIN.
02.35
02.3602.37
CO
NSTR
UC
TIO
N L
IMIT
LIN
E
CONSTRUCTION LIMIT LINE
02.41
8
10
A C
02.29
02.29
2
7
4
3
1
B
9
02.3202.32
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:21 PM
A-11
Flo
or &
Cei
ling
Dem
oliti
on P
lan
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
9SCALE: 1/8" = 1'-0"1Floor Demolition Plan
NORTH
KEYED NOTES
GENERAL NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 1/8" = 1'-0"2Ceiling Demolition Plan
NORTH
02.02 EXISTING WALL TO REMAIN.
02.03 CONTRACTOR TO REMOVE EXISTING WOOD TRIM AROUND EXISTINGELECTRICAL PANEL AND PREP FOR NEW TRIM.
02.05 EXISTING DOOR FRAME TO REMAIN; PROTECT DURING CONSTRUCTION.
02.06 EXISTING LOCATION OF ELECTRICAL DUCT BANK TO REMAIN. CONTRACTOR TOUSE EXTREME CAUTION WHEN WORKING / DIGGING ON OR AROUND DUCTBANK. COORDINATE W/ ELECTRICAL AND STRUCTURAL PLANS.
02.07 REMOVE WALL FOR DOOR AND/OR WINDOW OPENING. COORDINATE WITHFLOOR PLANS FOR LOCATION AND SIZE OF OPENING.
02.09 REMOVE WALL IN ITS ENTIRETY. COORDINATE REMOVAL OF MECHANICAL ANDELECTRICAL ITEMS IN WALL WITH MECHANICAL AND ELECTRICAL DRAWINGS.WHERE WALL WAS ATTACHED TO AN EXISTING WALL TO REMAIN, PATCH WALLTO SMOOTH FINISH.
02.10 REMOVE DOOR, FRAME, AND ALL ASSOCIATED HARDWARE.
02.11 EXISTING CONCRETE MOW STRIP TO REMAIN.
02.12 EXISTING PLANTER TO REMAIN.
02.13 EXISTING WINDOW AND SILL TO BE REMOVED, PREP FOR NEW WINDOW.
02.14 EXISTING WINDOW TO BE REMOVED. PATCH WALL TO MATCH EXISTING FINISH.
02.15 EXISTING CASEWORK TO BE REMOVED.
02.16 EXISTING PLUMBING FIXTURE TO BE REMOVED. COORDINATE WITH PLUMBINGDRAWINGS.
02.17 EXISTING EQUIPMENT, APPLIANCES, FURNITURE, ETC, TO BEREMOVED/RELOCATED.
02.18 EXISTING EQUIPMENT TO BE RELOCATED. COORDINATE WITH OWNER.
02.19 EXISTING COMBINATION DRENCH SHOWER/EYEWASH STATION TO BE REMOVEDCOMPLETE.
02.20 EXISTING TREE, SHRUB, GRASS, ETC. TO REMAIN.
02.21 EXISTING TREE, SHRUB, GRASS, ETC. TO BE REMOVED.
02.22 EXISTING SIDEWALK TO REMAIN.
02.23 EXISTING SIDEWALK TO BE REMOVED.
02.24 EXISTING MASONRY COLUMN TO BE REMOVED COMPLETE.
02.25 EXISTING STREET LIGHT TO REMAIN. PROTECT DURING CONSTRUCTION.
02.26 EXISTING DRAIN GRATE TO REMAIN.
02.27 EXISTING CEILING TO BE REMOVED IN THIS AREA.
02.28 PATCH HOLE IN EXTERIOR WALL AT AUTOCLAVE EXHAUST.
02.29 EXISTING LIGHT FIXTURE TO BE REMOVED.
02.30 EXISTING LIGHT FIXTURE TO REMAIN. THOROUGHLY CLEAN.
02.31 EXISTING DIFFUSER TO BE REMOVED.
02.32 WOOD INSIDE EXISTING SKYLIGHT TO RECEIVE NEW STAIN - TYPICAL OF (6).
02.33 EXISTING WOOD SOFFIT TO REMAIN. PREPARE TO RECEIVE NEW STAIN.
02.34 EXISTING D.I. TANKS AND PIPING TO BE RELOCATED. COORDINATE WITHOWNER.
02.35 CANOPY PRE CAST TO BE CAREFULLY REMOVED ON THIS SIDE.
02.36 SAWCUT CANOPY PRECAST TO LINE UP TO FACE OF NEW CMU WALL. FIELDVERIFY BEFORE CUTTING.
02.37 CAREFULLY REMOVE AND SAVE WOOD SOFFIT TO PROVIDE ENOUGH ROOM TOSURE UP THE ROOF DECK DURING CONSTRUCTION.
02.38 EXISTING CONCRETE FOOTING AND FOUNDATION TO BE REMOVED COMPLETE.
02.39 SAWCUT EXISTING ENTRY PLAZA SLAB AT JOINT WHERE SHOWN AND REMOVECOMPLETELY.
02.40 EXISTING DOOR TO BE REMOVED, PREP FOR NEW DOOR.
02.41 EXISTING BUILDING SIGNAGE TO BE REMOVED AND RELOCATED, COORDINATENEW LOCATION WITH OWNER.
-
8
A C
2
7
4
3
1
B
02.4802.48
02.06
02.49
~
02.5602.5602.57
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APP
ROV
ED
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV
. BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/31/2018 9:02:32 AM
A-11A
Enl
arge
d F
loor
Dem
oliti
on P
lan
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
10SCALE: 1/4" = 1'-0"1Floor Demolition Plan Enlarged
KEYED NOTES
GENERAL NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
NORTH
02.06 EXISTING LOCATION OF ELECTRICAL DUCT BANK TO REMAIN. CONTRACTOR TOUSE EXTREME CAUTION WHEN WORKING / DIGGING ON OR AROUND DUCTBANK. COORDINATE W/ ELECTRICAL AND STRUCTURAL PLANS.
02.48 SAWCUT EXIST. SLAB AS CLOSE TO EXIST. WALLS AS POSSIBLE AND REMOVECOMPLETE (SHOWN SHADED). LOCATE ALL EXIST. UTILITY LINES AND USEEXTREME CAUTION WHEN CUTTING AND REMOVING SLAB.
02.49 POSSIBLE LOCATION LINE OF EXIST. ELECTRICAL DUCT BANK TO REMAIN.CONTRACTOR TO USE EXTREME CAUTION WHEN WORKING / DIGGING ON ORAROUND DUCT BANK. COORDINATE W/ ELECTRICAL AND STRUCTURAL PLANS.
02.56 EXISTING SANITARY SEWER LINE TO BE PROTECTED DURING DEMOLITION.
02.57 CONTRACTOR TO TAKE EXTREME CAUTION DURING DEMOLITION WHENWORKING AROUND UNDERSLAB UTILITY LINES TO KEEP THEM INTACT ANDPROTECTED. COORDINATE WITH MECHANICAL AND ELECTRICAL.
-
101
VOLATILES
102
SEMI-VOLATILES
104
CUBBIES
105
ANALYST
OFFICE/FUTURE
METALS LAB 106
NUTRIENTS
107
OFFICE
109
MAIN LAB
117
STORAGE116
WET LAB
115
B.O.D. LAB
114
MICRO LAB
11
3
CO
RR
IDO
R
111
D.I. TANKS
103
GAS
112
STORAGE
2
A-41
1
A-41
A-16
1
A-15
1
A-14
1
EX
EXISTING
ELECTRICAL
CO
NSTR
UC
TIO
N L
IMIT
LIN
E
CO
NSTR
UC
TIO
N L
IMIT
LIN
E
CONSTRUCTION LIMIT LINE
CONSTRUCTION LIMIT LINE
NEW ADDITION
46' - 8"
110
BOTTLE
STORAGE
EX
ISTI
NG
BU
ILD
ING
77
' - 7
5/8
"
NEW
AD
DIT
ION
31
' - 4
"
8
10
A C
2
7
4
3
1
B
9
32.01
32.01
FINISH SLAB ELEVATION:
100' - 0" (ARCH) = 4300.5 (CIVIL)
2' - 1"
117
STORAGE
112
STORAGE
116
WET LAB
11
3
CO
RR
IDO
R
114
MICRO LAB
115
B.O.D. LAB
111
D.I. TANKS
109
MAIN LAB
107
OFFICE106
NUTRIENTS
105
ANALYST
OFFICE/FUTURE
METALS LAB
104
CUBBIES
EX
EXISTING
ELECTRICAL
19
EXIST.
WOMEN
20
EXIST.
MEN
18
EXIST.
WOMEN
LOCKER
103
GAS
102
SEMI-VOLATILES
101
VOLATILES
17
EXIST.
CONFERENCE
A-14
2
A-15
2
A-16
2
06.16
8
10
A C
2
7
4
3
1
B
9
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:28 PM
A-12
Flo
or P
lan
& R
efle
cted
Cei
ling
Pla
n
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
11
NORTH
KEYED NOTES
GENERAL NOTES
SCALE: 1/8" = 1'-0"1Level 1 Floor Plan
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 1/8" = 1'-0"2Level 1 Reflected Ceiling Plan
NORTH
06.16 RE-INSTALL WOOD SOFFIT PLANKS AND RE-STAIN ENTIRE WOOD ENTRY SOFFIT -COORDINATE STAIN COLOR W/ OWNER.
32.01 THIS AREA TO MATCH ADJACENT EXPOSED AGGREGATE FINISH.
-
2
A-41
1
A-41
8
GA-08
D.B.E. 113' - 10"
D.B.E. 113' - 10"
D.B.E. 113' - 10"
D.B.E. 113' - 10"
RID
GE
R.D.
O.R.D.
115' - 4"
EXISTING BUILDING PARAPET
113' - 10"
EXISTING CANOPY PARAPET
115' - 4"
EXISTING BUILDING PARAPET
115' - 4"
EXISTING BUILDING PARAPET
22.1522.15
07.03
07.03
D.B.E. 113' - 10"
D.B.E. 113' - 10"
07.01
EXISTING ROOF
EXISTING ENTRY CANOPY ROOF
8
10
A C
HATCHED AREA INDICATES
EXISTING ROOF AREA TO REMAIN
02.4202.42
02.43
TYP02.44
MATCH EXISTING
BUILDING PARAPET
MATCH EXISTING
BUILDING PARAPET
MATCH EXISTING
BUILDING PARAPET
TYP.
7
4
3
B
9
02.45
T.O.W. 115' - 4"
07.03
1/4
" P
ER
FO
OT,
MIN
.
1/4
" P
ER
FO
OT,
MIN
.
1/4" PER
FOOT, MIN.
1/4" PER
FOOT, MIN.
02.08
07.02
A-13
3
A-13
3
A-13
4
T.O.W. 115' - 4"
T.O.W. 115' - 4"
07.12
02.5002.50
02.55
6
GA-03
8
A C
7
4
3
B
9
02.51 02.51 02.51
02.51 02.52
02.5302.53
02.53
02.54
02.54
02.58
07.0107.01
07.0307.03
07.03
SPLIT F
ACE
SMOO
TH FIN
ISH
07.11
07.1207.03
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APP
ROV
ED
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV
. BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/31/2018 9:13:34 AM
A-13
Roo
f Pla
n
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
12
NORTH
KEYED NOTES
GENERAL NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 1/8" = 1'-0"1Roof Plan
SCALE: 1/8" = 1'-0"2Roof Demolition Plan
NORTH
CIVIL ARCH
T.O. PRECAST = 4315.83 = 115' - 4"
DECK BEARING = 4314.33 = 113' - 10"
FINISH FLOOR ELEVATION = 4300.50 = 100' - 0"
VERIFY ALL ELEVATIONS WITH EXISTING BUILDING
SCALE: 1 1/2" = 1'-0"3Roof Connection 3D
ELEVATION KEY
SCALE: 12" = 1'-0"4Roof Connection 3D
02.08 EXISTING ROOFING TO BE TIED INTO NEW PARAPET WALL AS REQUIRED.
02.42 EXISTING MECHANICAL SCREEN WALL TO REMAIN.
02.43 EXISTING MECHANICAL UNITS. SEE MECHANICAL
02.44 EXISTING ROOF DRAINS, TYP.
02.45 NEW MECHANICAL UNIT. SEE MECHANICAL DRAWINGS. PATCH & REPAIRROOFING SYSTEM AS REQUIRED AROUND NEW UNIT - MATCH EXIST. SYSTEM.
02.50 NEW FAN UNIT - PATCH EXIST. ROOFING SYSTEM AS REQUIRED AROUND NEWUNITS - MATCH EXIST. SYSTEM.
02.51 EXIST. FAN UNIT TO BE REMOVED - COORD. W/ MECH. DRAWINGS. PATCH EXIST.ROOFING SYSTEM AS REQUIRED - MATCH EXIST. ROOFING SYSTEM.
02.52 EXIST. MECH. UNIT TO BE REMOVED - COORD. NEW RTU W/ MECH. DRAWINGS.PATCH EXIST. ROOFING SYSTEM AS REQUIRED - MATCH EXIST. ROOFING SYSTEM.
02.53 EXIST. ROOF DRAINS TO REMAIN.
02.54 EXIST. ROOF TOP SCREEN WALL TO REMAIN.
02.55 NEW CONDENSER UNIT - COORD. PLACEMENT W/ MECH. DRAWINGS - COORD.ROOF CURB SUPPORT W/ STRUCTURAL. PATCH EXIST. ROOFING SYSTEM ASREQUIRED - MATCH EXIST. SYSTEM.
02.58 PATCH ROOFING MEMBRANE AT C.U. CURB PENETRATION.
07.01 SINGLE PLY 80 MIL. ROOFING MEMBRANE OVER TAPERED INSULATION. SEE WALLSECTIONS.
07.02 PROVIDE TAPERED INSULATION (WITH SLOPE 1/4" PER FOOT) IN THIS ROOF AREAFOR WATER DRAINAGE.
07.03 PARAPET CAP (COLOR TO MATCH EXISTING) HELD IN PLACE WITH CONTINUOUSCLEAT NAILED TO WOOD NAILER. SLOPE CAP TO DRAIN TO ROOF SIDE. ATTACHPARAPET CAP ON ROOF SIDE TO NAILER WITH GASKETED FASTENERS.
07.11 GALVANIZED SHEET METAL REGLET ATTACHED TO MASONRY WALLS, CURBS, ETC.
07.12 EXISTING ROOFING MEMBRANE TO EXTEND UP WALL AS REQUIRED TO BECOVERED BY NEW REGLET SYSTEM.
22.15 ROOF AND OVERFLOW DRAIN. SEE DETAIL 8/GA-08. COORDINATE NEW ROOFDRAIN AND OVERFLOW ROOF DRAIN LINES WITH MECHANICAL DRAWINGS.
-
101
VOLATILES
102
SEMI-VOLATILES
104
CUBBIES
103
GAS
EX
EXISTING
ELECTRICAL
102B
102A
A-319 10
A-31 6
5
4
7
A-311
3
A3
A-31
B1
B1
B1
F1
F1
F1
P1
P1
P1
SS1
09.17
09.15
11.0211.02
TYP06.03
A-31
8
2
COMP.
HELIUM
101A
103A
104A
A
A
SS1
11.02
8' - 8 1/4"
SS1
3' - 0"
D
E
11.03
2 2
4 4
3 3
1 1
B
B
SS1
A-14
3
PL1
PL1
GA-08
2
PL2
PL2
P2
P2
P2
P2
P2
4
A-15F3 3
' - 0
"
3' - 0"
6' -
11
1/2
"
13.01
13.0213.02118A
101
VOLATILES
102
SEMI-VOLATILES
104
CUBBIES
103
GAS
EX
EXISTING
ELECTRICAL
109' - 0"
109' - 0"
109' - 0"
TYP26.01
TYP23.07
A
A
2 2
4 4
3 3
1 1
B
B
OPEN
2' -
1"
6' - 8"
LINE OF BASE
CABINETS BELOW
1"
3"
2' -
2"
1"
1 1/2"LEGS
3 1/2" x 3 1/2"
05.0305.03
09.09
06.1906.19
05.04
3"
3"
3"
3"
06.2106.21
09.09
05.03
05.03
06.1906.19
05.04
1"
3"
3"
3"
3"
3"
06.2206.22
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:35 PM
A-14
Enl
arge
d P
lans
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
13
NORTH
KEYED NOTES
GENERAL NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 1/4" = 1'-0"1Enlarged Plan
SCALE: 1/4" = 1'-0"2Enlarged Reflected Ceiling Plan
NORTH
SCALE: 1/2" = 1'-0"3Enlarged Countertop Plan
SCALE: 1 1/2" = 1'-0"4Volatiles/Semi-Volatiles Table End Enlarged
SCALE: 1 1/2" = 1'-0"5Volatiles/Semi-Volatiles Table Center Enlarged
05.03 METAL ANGLE SUPPORTS, 1" X 1" AT 18" O.C. AROUND ENTIRE PERIMETER.
05.04 TABLE LEVELER AT EACH SUPPORT.
06.03 CABINETS, COUNTERTOPS, BOOKSHELVES, ETC. SEE INTERIOR ELEVATIONS.
06.19 WOOD TABLE FRAME AND SUPPORTS TO MATCH CABINETS.
06.21 WOOD LEG BRACES, 3/4" X 3". INSET FLUSH WITH INSIDE FACE OF TABLE LEGS(EACH END OF TABLE) WOOD BRACES TO MATCH CABINETS.
06.22 WOOD LEG BRACES, 3/4" X 3". INSERT FLUSH ON BOTH SIDES OF MIDDLE TABLELEGS AS SHOWN. WOOD BRACES TO MATCH CABINETS.
09.09 EPOXY RESIN COUNTERTOP, BLACK.
09.15 THRESHOLD WHERE NEW FLOORING MEETS EXISTING FLOORING. SEE DETAILS5/GA-09.
09.17 THRESHOLD AT ENTRANCE. SEE DETAIL 9/GA-08.
11.02 FUME HOOD. SEE MECHANICAL DRAWINGS. PROVIDE METAL TRIM PIECE TOCLOSE SPACE BETWEEN TOP OF HOOD AND CEILING.
11.03 APPLIANCES (REFRIGERATOR), O.F.O.I. SEE MECHANICAL, ELECTRICAL, ANDPLUMBING DRAWINGS FOR UTILITY REQUIREMENTS.
13.01 DUST PARTITION, 2X4 STUDS WITH PLYWOOD EACH SIDE, FLOOR TO CEILING. FILLWITH SOUND BATTS. UPON COMPLETION, REMOVE DUST PARTITION, AND REPAIRSURROUNDING FINISHES.
13.02 DUST PARTITION, 2X4 STUDS WITH PLYWOOD EACH SIDE, FLOOR TO CEILING. FILLWITH SOUND BATTS. PROVIDE TEMPORARY DOOR. UPON COMPLETION,REMOVE DUST PARTITION AND DOOR, AND REPAIR SURROUNDING FINISHES.
23.07 DIFFUSER. SEE MECHANICAL DRAWINGS.
26.01 LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS. ELECTRICAL CONTRACTOR SHALLCOORDINATE WITH GENERAL AND OTHER SUBCONTRACTORS AND CONCEALALL CONDUITS.
-
109
MAIN LAB
21
' - 1
7/8
"
4' - 11"
40' - 11 1/4"
EX
ISTI
NG
8' - 2 3/8"
6' - 3 3/4" 3' - 4" 9' - 11 5/8" 10" 4' - 6" 2' - 8" 5' - 4" 8' - 0"
5' -
0"
7' -
0 5
/8"
5' -
0"
6' - 6 3/4" 10' - 1 1/2" 10' - 1 1/2" 14' - 1 5/8"
6' -
0"
6' -
0 1
/4"
8' -
3 7
/8"
10
' - 2
1/2
"
105
ANALYST
OFFICE/FUTURE
METALS LAB 106
NUTRIENTS
107
OFFICE
A3 A3
A3
A3A3
A3
A3A3
A3
105A 106A
107A
A-31
12
13
14
11
A-32
4
2
3
1
A A
5' - 9 5/8" 4' - 4"
09.17
09.15
SS1
SS1
SS1
P1P1
P1
P1
F1F1
F2
F1
B1B1
B1
B1
11.02 11.0211.0222.09
09.08
11.02
06.03
06.03
WEIGH BENCH
WEIGH
BENCH
FUTURE
HOOD
FUTURE SINK
STUB OUTS
ONLY
VAC.109A
109B
A-32
A-32
A-32
A-325
8
7
6
09.15
SS1
SS1 SS1
SS1
8
C
06.03 06.0306.03
22.04
GA-09
3
B
B
C
7
B
B
SS1
SS1
3' -
0"
02.02
3
A-15
(BELOW)
06.09
PL1
PL1
P2
06.08
26.05
11.08
3' -
11
"
8"4 3/4"
PL2
PL2
P2
P2
P2P2
P2
09.13
109
MAIN LAB
105
ANALYST
OFFICE/FUTURE
METALS LAB106
NUTRIENTS
107
OFFICE
109' - 0"
109' - 0"
109' - 0"
109' - 0"
108' - 0"
TYP23.07
8
A C
26.02
26.02
23.07
TYP23.07
TYP26.01
7
B
B
09.05
23.07
OPEN
108' - 0"
1" 7"
9"
01.02
26.03
09.09
1"
GA-06
7
SIM.
1. PORCELAIN FLOOR TILE, SEE FINISH LEGEND.
2. FLUID APPLIED WATER PROOF MEMBRANE (C.I.S.) ANSI A118.10.
3. MORTAR BED.
4. INTEGRATED BONDING FLANGE.
5. FLOOR DRAIN AS OCCURS. SEE PLUMBING DRAWINGS. SAW CUT FLOOR SLAB
AS REQUIRED.
6. ALL NEW TILE FLOORING SHALL BE BUILT UP AS REQUIRED TO SLOPE DRAIN.
CONTRACTOR TO FIELD VERIFY SETTING BED REQUIRED.
7. HIGH POINT LOCATION AS REQUIRED TO SLOPE TOWARD DRAIN. SEE FLOOR
PLANS.
8. TOP OF CONCRETE FLOOR SLAB.
9. SHOWER PAN LINER.
10. RECESSED SLAB AS INDICATED ON STRUCTURAL DOCUMENTS.
11. FLOOR TILE, SEE FINISH PLAN.
NOTE:
FLUID APPLIED WATERPROOF MEMBRANE TO 12" A.F.F @ DRY WALLS, TO CEILING AT
WET WALLS.
2
6
1 3 4 3
6
1
7
SLOPE SLOPE
5
CL
10 9
7
8
KEYED NOTES
2"x2" TILE TO ALLOW FOR SLOPE
11
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:39 PM
A-15
Enl
arge
d P
lans
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
14
NORTH
KEYED NOTES
01.02 LINE OF WALL.
02.02 EXISTING WALL TO REMAIN.
06.03 CABINETS, COUNTERTOPS, BOOKSHELVES, ETC. SEE INTERIOR ELEVATIONS.
06.08 GROMMET, FACTORY CUT.
06.09 CONTRACTOR TO INSTALL NEW TRIM AROUND EXISTING ELECTRICAL PANEL.TRIM TO MATCH CABINETS AND DOORS.
09.05 EXISTING WOOD SOFFIT TO BE RE-STAINED - TYPICAL AT ALL EXTERIOR WOODSOFFITS. FIELD VERIFY EACH LOCATION AND COORDINATE WITH OWNER.
09.08 WINDOW SILL (SOLID SURFACE). SEE WALL SECTIONS. ADHERE TO WINDOWFRAMING AS REQUIRED.
09.09 EPOXY RESIN COUNTERTOP, BLACK.
09.13 GYP. BD. ON NEW WINDOW INFILL FRAMING TO BE FLUSH W/ EXIST. LOBBYFINISHES. PAINT ENTIRE LOBBY NORTH WALL TO MATCH EXIST. FINISHES.
09.15 THRESHOLD WHERE NEW FLOORING MEETS EXISTING FLOORING. SEE DETAILS5/GA-09.
09.17 THRESHOLD AT ENTRANCE. SEE DETAIL 9/GA-08.
11.02 FUME HOOD. SEE MECHANICAL DRAWINGS. PROVIDE METAL TRIM PIECE TOCLOSE SPACE BETWEEN TOP OF HOOD AND CEILING.
11.08 ELECTRIC HAND DRYER - COORD. W/ ELECTRICAL
22.04 TROUGH DRAIN (24" L X 6" W X 6" D), SLOPED TOWARD SINK AT 1/4" PER FOOT.PROVIDE BLOCKING IN MILLWORK TO PROPERLY SUPPORT TRENCH.
22.09 SINK. SEE PLUMBING DRAWINGS.
23.07 DIFFUSER. SEE MECHANICAL DRAWINGS.
26.01 LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS. ELECTRICAL CONTRACTOR SHALLCOORDINATE WITH GENERAL AND OTHER SUBCONTRACTORS AND CONCEALALL CONDUITS.
26.02 EXISTING LIGHT FIXTURE TO REMAIN. CONTRACTOR TO VISUALLY INSPECT EACHEXISTING LIGHT FIXTURE TO REMAIN TO ENSURE THEY ARE IN PROPER WORKINGORDER. CLEAN AND RELAMP AS REQUIRED.
26.03 ELECTRICAL BOX WHERE OCCURS. SEE ELECTRICAL DRAWINGS.
26.05 SURFACE ELECTRICAL OUTLETS. SEE ELECTRICAL DRAWINGS.
GENERAL NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 1/4" = 1'-0"1Enlarged Plan
NORTH
SCALE: 1/4" = 1'-0"2Enlarged Reflected Ceiling Plan
SCALE: 1 1/2" = 1'-0"3Upper Cabinet Section
SCALE: 3" = 1'-0"4Floor/Trench Drain Detail
-
2
A-41
1
A-41
117
STORAGE
116
WET LAB
112
STORAGE
111
D.I. TANKS
21
' - 3
7/8
"1
5' -
4 1
/8"
10
' - 0
1/8
"
6' -
10
"
2' - 0 7/8" 5' - 4" 2' - 10"
109
MAIN LAB
114
MICRO LAB
115
B.O.D. LAB
15
' - 6
"1
5' -
10
"
4' - 11" 15' - 7"
D3
D3
A3
A3
A3
A3
E3 A3
A3A3
A3
A3A3
A3
A3
A3
E3
B B
117A
112A
116A
115A
114A
A
B
A-34 4
A-33
6
A-33
8
2
3
5
7
10
9
53
4
A
A-42
3A-42
4
113
CORRIDOR
F1
F1
F1
F1
F1
F1
B1
B1
B1
B1
B1
B1P1
P1
P1
P1
P1
P1
SS1 SS1
SS1
SS1
SS1
11.04
09.0809.08
09.08
CART
STORAGE
11.0311.03
11.0311.03
FLA
MM
AB
LE S
TOR
AG
E
CA
BIN
ET
BY
OW
NER COMP. AIR
AUTOCLAVE
O.F.O.I.
110
BOTTLE
STORAGE
VAC
VAC.
GAS
AIR
G3
A3
F3
111A
110A
A-33
2
1
A-3311
12
13
A-34
1
8
10
A
A
C
C
5' - 5"
32
' - 0
"
8"
10' - 2 7/8" 19' - 10" 8"
45' - 4"
5' -
7 7
/8"
4' -
0"
4' - 10" 5' - 0 5/8" 4' - 0"
5' -
4"
6' -
0"
GA-08
2 GA-09
1
GA-09
2
10.01
10.0110.01
10.0210.0210.02
10.0210.0210.02
11.07
7' -
0"
7
B
B
SS1
9
06.18
PL1
PL1
PL105.24
8"
5' - 4" 7' - 4"
PL2
PL2
PL2
P2
P2
P2
2
A-41
1
A-41
117
STORAGE
116
WET LAB
115
B.O.D. LAB
114
MICRO LAB
113
CORRIDOR
112
STORAGE111
D.I. TANKS
109
MAIN LAB
109' - 0"
109' - 0"
109' - 0"
109' - 0"
109' - 0"
109' - 0"
108' - 0"
TYP26.01
TYP23.07
110
BOTTLE
STORAGE
8
10 10
A
A
C
C
7
B
B
9
OPEN
OPEN
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:42 PM
A-16
Enl
arge
d P
lans
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
15
NORTH
KEYED NOTES GENERAL NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 1/4" = 1'-0"1Enlarged Plan
SCALE: 1/4" = 1'-0"2Enlarged Reflected Ceiling Plan
NORTH
05.24 STEEL COLUMN. SEE STRUCTURAL DRAWINGS.
06.18 SHELF FOR STEREO, O.F.O.I. TO BE MOUNTED AT 42" A.F.F.
09.08 WINDOW SILL (SOLID SURFACE). SEE WALL SECTIONS. ADHERE TO WINDOWFRAMING AS REQUIRED.
10.01 METAL SHELVING UNITS TO BE PROVIDED AND INSTALLED BY OWNER.
10.02 INCUBATOR, O.F.O.I. COORDINATE REQUIREMENTS W/ OWNER.
11.03 APPLIANCES (REFRIGERATOR), O.F.O.I. SEE MECHANICAL, ELECTRICAL, ANDPLUMBING DRAWINGS FOR UTILITY REQUIREMENTS.
11.04 DI TANKS - PROVIDED BY OWNER.
11.07 HYDRAULIC LIFT - COORDINATE REQUIREMENTS W/ OWNER. O.F.O.I.
23.07 DIFFUSER. SEE MECHANICAL DRAWINGS.
26.01 LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS. ELECTRICAL CONTRACTOR SHALLCOORDINATE WITH GENERAL AND OTHER SUBCONTRACTORS AND CONCEALALL CONDUITS.
-
115' - 4"
TOW
113' - 10"
TO CMU
101' - 2"
T.O. CONCRETE
SEE CIVIL
FINISH GRADE
2
A-41
EXISTING BUILDING NEW CONSTRUCTION
03.01
07.03
08.0208.02
08.0208.02
8 10
04.04
03.08
03.07
04.05
2 7431 9
SEE CIVIL
T.O. FOOTING
22.08 26.04
115' - 4"
TOW
113' - 10"
TO CMU
101' - 2"
TO CONCRETE
VARIES
FINISH GRADE
2
A-41
NEW CONSTRUCTION EXISTING BUILDING03.01
07.03
08.02
03.10
810
04.05
04.04
03.08
03.07
9
04.15
115' - 4"
TOW
113' - 10"
TO CMU
101' - 2"
TO CONCRETE
SEE CIVIL
FINISH GRADE
1
A-41
EXISTING BUILDINGNEW CONSTRUCTION
03.1003.10
08.0208.02
03.01
07.03
A CB
03.08
03.07
26.04 26.04 02.46
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:46 PM
A-21
Ext
erio
r E
leva
tions
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
16
SCALE: 3/16" = 1'-0"1Exterior Elevation - North
SCALE: 3/16" = 1'-0"2Exterior Elevation - South
SCALE: 3/16" = 1'-0"3Exterior Elevation - West
KEYED NOTES
GENERAL NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
02.46 EXISTING BUILDING SIGNAGE TO BE RELOCATED TO THIS APPROXIMATELOCATION. COORDINATE WITH OWNER.
03.01 CONCRETE PARAPET WALL CAP TO MATCH EXISTING. ATTACH PER STRUCTURALDRAWINGS.
03.07 CONCRETE FOOTING. SEE STRUCTURAL DRAWINGS.
03.08 CONCRETE FOUNDATION WALL WITH PARGE COAT FINISH. SEE STRUCTURALDRAWINGS.
03.10 EXTERIOR PRECAST CONCRETE WINDOW SILL.
04.04 CONCRETE MASONRY UNIT (C.M.U.) SPILT-FACED WALL, COLOR TO MATCHEXISTING BUILDING. SEE STRUCTURAL DRAWINGS.
04.05 8 X 8 CMU WINDOW HEADER TO MATCH EXISTING BUILDING.
04.15 HATCHED AREA INDICATES SMOOTH FACED CMU, COORDINATE EXTENTS WITHARCHITECT PRIOR TO INSTALLATION.
07.03 PARAPET CAP (COLOR TO MATCH EXISTING) HELD IN PLACE WITH CONTINUOUSCLEAT NAILED TO WOOD NAILER. SLOPE CAP TO DRAIN TO ROOF SIDE. ATTACHPARAPET CAP ON ROOF SIDE TO NAILER WITH GASKETED FASTENERS.
08.02 NEW WINDOW. SEE WINDOW TYPES FOR SIZE, SEE FLOOR PLAN FOR SILL TYPE.
22.08 SECONDARY (OVERFLOW) ROOF DRAIN SPOUT. COORDINATE SPOUT INVERTELEVATION WITH AVAILABLE CEILING SPACE. DO NOT LOCATE SPOUT DIRECTLYOVER LIGHT FIXTURES OR AT DOORWAYS.
26.04 NEW EXTERIOR LIGHT. SEE ELECTRICAL DRAWINGS.
-
2' -
6"
1" 4' - 1" 4' - 1" 1"
CL
A-14
4A-14
5
08.06
09.01
8' - 4"
2' - 0" 2' - 6"
2' -
10
"1
' - 1
0"
4' -
4"
B3 B509.01 08.01
4' - 6"
W1
2' - 0"2' - 0"09.0709.0111.02
1"
3 1
/2"
2' -
1 1
/2"
1" 1' - 10" 1"
A-14
4
2' - 0" 2' - 0"
1' -
1"
4' -
11
"3
' - 0
"
8"
3' -
0"
09.01
08.06
2' - 0"
3' -
0"
3' -
0"
08.01 09.01
11.0211.02
12.0112.0109.01
7' - 8"
2' -
6"
1' - 6"
B3 B5
3' - 0"
3' -
0"
8"
2' -
0"
08.0109.01
2' - 0" 2' - 0"
3' - 0"
2' -
6"
09.12
06.07
B3
2' - 0"
B4 B4
3' - 6" 3' - 6"
3' -
0"
09.01
09.01
08.01
T1
2' - 10" 2' - 10" 2' - 10"
T1 T1
7' -
2"
09.01 11.03
2' - 10" 2' - 10"
09.01 T1 T1 09.0122.14
7' -
2"
3' - 0" 3' - 0" 2' - 0"
B4 B4 B6
8"
3' -
0"
11.02
08.02
09.01
09.12
1' - 0" 3' - 6" 1' - 0"
8"
3' -
0"
B3 B5 B3 09.01
09.12
3' - 0" 3' - 0" 3' - 0"
3' - 0" 3' - 0" 3' - 0"
4' -
8"
4' -
4"
B4 B4
W1 W1 W1
08.0109.01
OPEN
09.123
' - 0
"
09.01
3' -
0"
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:51 PM
A-31
Inte
rior
Ele
vatio
ns
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
17
KEYED NOTES
KEYED NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 3/8" = 1'-0"1Volatiles - North
SCALE: 3/8" = 1'-0"3Volatiles - West
SCALE: 3/8" = 1'-0"2Volatiles - East
SCALE: 3/8" = 1'-0"4Semi-Volatiles - North
SCALE: 3/8" = 1'-0"5Semi-Volatiles - East
SCALE: 3/8" = 1'-0"6Semi-Volatiles - South
SCALE: 3/8" = 1'-0"7Semi-Volatiles - West
SCALE: 3/8" = 1'-0"8Semi-Volatiles - West
SCALE: 3/8" = 1'-0"9Cubbies - North
SCALE: 3/8" = 1'-0"10Cubbies - South
SCALE: 3/8" = 1'-0"11Nutrients - North
SCALE: 3/8" = 1'-0"12Nutrients - East
SCALE: 3/8" = 1'-0"13Nutrients - South
SCALE: 3/8" = 1'-0"14Nutrients - West
06.07 DRYING RACK, COORDINATE REQUIREMENTS WITH OWNER.
08.01 NEW DOOR FRAME AND DOOR. SEE DOOR SCHEDULE FOR DOOR SIZE, DOORELEVATION, ETC.
08.02 NEW WINDOW. SEE WINDOW TYPES FOR SIZE, SEE FLOOR PLAN FOR SILL TYPE.
08.06 NEW WINDOWS IN EXIST. WINDOW OPENING - FIELD VERIFY EXISTING OPENINGSIZE.
09.01 NEW WALL BASE. SEE FINISH SCHEDULE.
09.07 FULL HEIGHT BACKSPLASH.
09.12 EPOXY RESIN BACKSPLASH - EXTEND TO WINDOW SILL IN AREAS SHOWN.
11.02 FUME HOOD. SEE MECHANICAL DRAWINGS. PROVIDE METAL TRIM PIECE TOCLOSE SPACE BETWEEN TOP OF HOOD AND CEILING.
11.03 APPLIANCES (REFRIGERATOR), O.F.O.I. SEE MECHANICAL, ELECTRICAL, ANDPLUMBING DRAWINGS FOR UTILITY REQUIREMENTS.
12.01 FURNITURE, EQUIPMENT, ETC., O.F.O.I.
22.14 COMBINATION DRENCH SHOWER/EYEWASH STATION WITH FULL CURTAIN.
-
09.01B4 B5 B4 B4 B4
3' - 0" 3' - 6" 3' - 0" 3' - 0" 3' - 0"
2' -
6"
4' - 0"
08.01 06.17
4' - 8"
9
GA-06
B4
2' - 9"
3' -
0"
OPEN
08.0608.06
09.12
B4
2' - 6"
OPEN
09.01
08.0111.0211.0211.02
8' -
0"
11.08
09.01
3' - 6" 3' - 0" 3' - 6"
3' - 6" 3' - 0" 3' - 6"
B4 B4 B4
W1W1W1
3
A-15
02.02
9"
3' -
0"
4' -
4"
11
"
SIM. SIM. SIM.
1' -
0"
5' -
6"
OPEN
09.01
08.01
3' -
0"
8"
2' - 6" 3' - 0" 3' - 0"
B4 B4 B4
2' -
6"
2' -
6"
11.05 B4
3' - 0" 3' - 0"
108' - 0"
OPEN OPEN OPEN
09.01
09.1209.1209.12
09.12
5' -
6"
1' -
0"
B3 B5 B3
1' - 6" 2' - 3" 1' - 6"
3' -
0"
06.07
2' -
4"
3' - 0"
B4
3' -
0"
B3
1' - 6" 2' - 3" 1' - 6"
B309.01B4 B6 B4 B7 B4 B4
3' - 0" 2' - 0" 2' - 6" 4' - 0" 3' - 0" 3' - 0"
3' -
0"
9
A-32
09.01
2' - 9"
6
A-34
06.2006.20
06.2006.20
B4 B4 B7 B4 B6 B4
3' - 0" 3' - 0" 4' - 0" 2' - 6" 2' - 0" 3' - 0"
3' -
0"
9
A-32
6
A-34
06.2006.20
06.2006.20
09.01
6' - 0"
1' - 10" 2' - 0"2' - 0"
01.01
3' -
0"
SELVAM
RAJAVELU
267857-0301
PRO
JECT
N
UM
BER
DA
TE
DRAWING NO.
SHEET OF
DES
IGN
REVI
EW
DES
IGN
DRA
WN
CHEC
KED
APPR
OVE
D
VERIFY SCALE
BAR
IS O
NE
INCH
ORI
GIN
AL
DRA
WIN
G
REVI
SIO
NS
NO
.D
ATE
REV.
BY
DES
CRIP
TIO
N
79
5272 S. College Drive, Suite104Murray, Utah 84123
10/30/2018 1:44:56 PM
A-32
Inte
rior
Ele
vatio
ns
So
uth
Va
lle
y W
ate
r R
ecl
am
ati
on
Fa
cili
ty
Lab
Exp
ansi
on a
nd R
emod
el7
49
5 S
ou
th 1
30
0 W
est
We
st J
ord
an
, U
tah
84
08
4
17
90
6.0
0O
cto
be
r 2
5,
20
18
18
KEYED NOTES
KEYED NOTES
A. SEE SHEETS A-02 AND A-04 FOR SYMBOLS, GENERAL NOTES AND LEGEND.
B. SEE SHEET A-53 FOR FINISH SCHEDULE.
C. SEE SHEET A-51 FOR DOOR SCHEDULE.
D. SEE SHEET A-52 FOR WINDOW SCHEDULE.
E. ALL EXISTING WALLS TO REMAIN ARE TO BE PATCHED AND REPAIRED AND MADEREADY TO RECEIVE NEW FINISHES.
SCALE: 3/8" = 1'-0"1Main Lab - North
SCALE: 3/8" = 1'-0"3Main Lab - East
SCALE: 3/8" = 1'-0"2Main Lab - South
SCALE: 3/8" = 1'-0"4Main Lab - West
SCALE: 3/8" = 1'-0"5Main Lab Island - South
SCALE: 3/8" = 1'-0"7Main Lab Island - North
SCALE: 3/8" = 1'-0"6Main Lab Island - West
SCALE: 3/8" = 1'-0"8Main Lab Island - East
SCALE: 3/8" = 1'-0"9Island Section
01.01 VOID SPACE CANNOT BE MORE THAN 3' - 0" IN WIDTH.
02.02 EXISTING WALL TO REMAIN.
06.07 DRYING RACK, COORDINATE REQUIREMENTS WITH OWNER.
06.17 WEIGH BENCH, BY OWNER.
06.20 FALSE PANELS TO MATCH DRAWERS AND DOORS WITHOUT PULLS, TYPICAL ATEACH CORNER.
08.01 NEW DOOR FRAME AND DOOR. SEE DOOR SCHEDULE FOR DOOR SIZE, DOORELEVATION, ETC.
08.06 NEW WINDOWS IN EXIST. WINDOW OPENING - FIELD VERIFY EXISTING OPENINGSIZE.
09.01 NEW WALL BASE. SEE FINISH SCHEDULE.
09.12 EPOXY RESIN BACKSPLASH - EXTEND TO WINDOW SILL IN AREAS SHOWN.
11.02 FUME HOOD. SEE MECHANICAL DRAWINGS. PROVIDE METAL TRIM PIECE TOCLOSE SPACE BETWEEN TOP OF HOOD AND CEILING.
11.05 VENT FOR CPU.
11.08 ELECTRIC HAND DRYER - COORD. W/ ELECTRICAL
-
5' - 0"
4' -
6"
4' -
6"
T2 09.01
4' -
6"
4' -
6"
4' - 0"4' - 0"
T2T2 09.01
08.01
09.01B6
2' -
6"
2' - 0"
09.1209.12
B4
2' - 6"
09.01
3' -
0"
3' - 6" 3' - 3"
B4 B4
09.12
08.02
09.01
3' - 0" 3' - 6" 3' - 6"
8"
3' -
0"
AUTOCLAVE
B4 B5 B4