Independent Liquid Terminals Association
PROGRESS TOWARD IMPLEMENTATION
THE VIEW FROM THE MIDDLE
Petroleum Industry Workshop on ULSD
November 10-11, 2005
• Workshop on ULSD for ILTA members on October 18-19– D & T—a critical component of compliance– Legal and contract issues—a major concern– Sulfur testing—need for policies and procedures– Consensus on key issues
• Receipts from pipelines• Deliveries to petroleum marketers• Contract with fuel owner
ILTA PROGRESS REPORT
RECEIPTS FROM PIPELINES
• Deliveries to terminals should not exceed 13 ppm.
• To meet customer needs, terminals expect to receive 13 ppm.
• Why do pipeline customers need 13 ppm deliveries at terminals?– ULSD contamination is a new market risk.– No built-in tolerance for terminals and
distributors.
ROLE OF TERMINAL CUSTOMERS
• Typically, the terminal customer owns the fuel.
• Most independent terminals are for-hire– Do not own the product– Facilities available to general public– Generally serve multiple customers– Customers are usually shippers on the pipeline
served by the terminal
• If necessary, terminals will ask customers to request pipelines to deliver at 13 ppm.
WHY IS 13 PPM CRITICAL?
• Terminals are the collision point of two unchangeable limitations coming from opposite directions.– Refiners will produce at no less than 8 ppm.
– Retailers will sell at no more than 15 ppm.• No safety margin for terminals if—
– Incoming ULSD is 14-15 ppm– Downstream parties need at least 1 ppm– Testing tolerance of 2 ppm remains unchanged
• ULSD rules create multiple economic risks.• If contamination causes downgrades or retail
violations, customer pays economic price.– Loss of revenue due to
• Lower selling price• Lower sales volume
– Additional costs of storage and handling– Inability to take full advantage of market changes
• Strong incentive to reduce contamination
INCENTIVES FOR CUSTOMER INTERVENTION
• Manage contamination risks– At all points along the distribution chain
• How will terminal customers do that?– Allocate reasonable contamination “allowances”
among the parties that transport and distribute the fuel
– Ensure that pipeline share of allowance is limited• Enhance probability of avoiding downgrades• Reduce risk of violations at retail level
OBJECTIVE OF CUSTOMER INTERVENTION
LEGAL ISSUES
• Liability risk for terminals– Minimal “safety margin” for sulfur content of ULSD
handled by terminals– Automatic presumption of liability– Measurement of sulfur content—a critical element
of affirmative defense– Sulfur testing variability is too large to ensure
measurements that resolve liability– Frequency of sampling and testing by terminals
PARALLEL LEGAL PROCEEDINGS
• EPA enforcement actions– Notice of violation
• Terminals presumed liable, in absence of clear cause• Assumption: contaminated fuel in distribution system for
25 days
– Penalties up to $32,500 per violation per day
• Civil lawsuits– Breach of implied warranty– Misrepresentation of product specification– Unfair trade practice under state law
DEFENSE OPTIONS FOR TERMINALS
• Defenses to EPA enforcement action– EPA test result is wrong– Section 80.613 defenses
• Violation not caused by terminal operator• Product transfer documents show fuel in compliance• Adequate quality assurance and testing program
• Defenses to civil lawsuits– Test results are wrong– No damage to diesel engines– Compliance with EPA regulations– “Causation” not shown
SULFUR TESTING CHALLENGE
• Testing is critical for limiting liability.– Must rely on very small differentials in sulfur
content (1-2 ppm) for affirmative defense, but—
• Testing does not provide reliable, consistent measurement of small differences in sulfur content.
• The reality: excessive variance in results– Different testing methods
• Labs, on-site (bench top and online), mobile labs
– Variations in testing conditions and technician training
WHOSE TEST PREVAILS?
• Pipeline delivers to terminal– Pipeline test shows 13– Terminal test shows 15
• EPA inspects terminal tank– Terminal’s sample tests at 15– EPA’s sample tests at 18 (Tank shutdown?)
• EPA samples tank at retail outlet– EPA test shows 18 (NOV triggered?)– Retailer’s subsequent test indicates 17 (No NOV?)
DISCUSSIONS WITH CUSTOMER
• Notify customer (ULSD owner) of need for 13 ppm fuel delivered to terminal.
• Define consequences when delivery is non-conforming—– When fuel is 13-15 ppm– When fuel exceeds 15 ppm– Testing by customer, and procedure when results
differ
• Statement of truck loading policy• Downgrading and redesignation limitations
DISCUSSIONS WITH PIPELINE
• Agreement that fuel will not exceed 13 ppm, except under defined circumstances
• Protocols when nonconforming fuel delivered—– Fuel tests at 13-15 ppm– Fuel exceeds 15 ppm– Pipeline bears burden of downgrade?– Differences in sulfur test results– Do pipeline tariff provisions cover all potential
ULSD issues?
DISCUSSIONS WITH MARKETERS
• Will the marketer (or tank truck operator) agree to use trucks dedicated to ULSD?
• If not, agree on contractual requirements– No prior delivery of high sulfur fuel– Adequacy of truck draining and cleaning
• Truck driver training requirements• Increased risk of static discharges
– Use of conductivity improver– Truck operator’s insurance coverage
ACTIONS WITHIN TERMINALS
• Establish sulfur testing regimes– Self-testing or outside lab– Frequency of sampling and testing – Reliance on non-tested samples
• Detailed procedures for non-conforming fuel– When fuel is 13-15; when fuel exceeds 15
• Develop ULSD compliance manual• Provide indemnification of owners
– Parent, joint venture partners, individuals
ULSD COMPLIANCE MANUAL
• Essential tool for—– Reducing contamination risk– Limiting liability and reducing penalties
• Prescribe measures for protecting fuel• List procedures employed when fuel found to
be non-complying– Identify cause, take corrective actions– Criteria for lockdown of a tank holding non-
complying fuel– Identify downgrade limitations
TransMontaigne
ULSD
Sampling and Testing Program
TransMontaigne
ULSD
Sampling and Testing Program
Testing LocationsTesting Locations
1. TMG Lab – Port Manatee, Florida (Lab Manager – ASTM Member on D02 Committee)A. Sulfur Test Machines
1. ULSD “Horiba” Sindie 7039 – Monochromatic Wavelength Dispersive X-ray Flourescence (MWDXRF)a. Range 1 PPM – 3,000 ppmb. 5 mL Sample Sizec. Method ASTM D-7039d. Single Samplee. Will be certifying lab procedures with EPA
Testing LocationsTesting Locations
Sulfur Test Machines (con’t)
2. LSD / Gasoline -- “ Horiba” since SLFA 2800 –Dispersive X-ray Fluorescence Analyzera. Range 5 ppm+ (.0005 Wt. / % - 10.0 Wt. / %)b. 4 – 10 mL Sample Sizec. Method ASTM D-4294d. 8 Sample Carousele. Internal Round Robin – Develop Bias + / -
2. Local Third Party Inspection Labs
3. Terminal Testing - *(Possibly Share Sites)
Sample / Test ProtocolSample / Test Protocol1. Initial Plan
A. Tank Baseline – sample / test prior to first ULSD receiptB. Test Tank (U, M, L) – following each receipt until tank is “turned”1. Receipt “Composite” Sample – retained 60 day /
minimuma. Pipeline – Head, Middle, Tail*b. Vessel – Composite of Compartments
*Sample size can be limited to 2-4 oz.Sample submitted shipped overnight (see shipping plan)
2. Upon Successful “Turn” (15 ppm or less) of tankA. Submit tank sample to third party lab for outside
confirmation
Sample / Test ProtocolSample / Test Protocol
3. EPA Regulations in Effect -- “Presumptive Liability”A. Test each tank after every receipt
1. Local Inspection Testing Available – use third party2. Extremely High Volume Terminals (own testing)3. All Others Will Use TMG Company Lab (see shipping
section)B. Retain Vessel or Pipeline Composite Sample – 60 day /
minimumC. Pull and Retain Daily* Load Rack Sample – 60 day /
minimum *If tank to truck rack changes, new retain must be taken following displacement of line fill.
Sample / Test ProtocolSample / Test Protocol
4. “Oversight Program”
A. TMG Lab or Terminal Test1. Any result in exceedance of the Regulatory
Specification requires immediate retest and possible lockdown of tank(s) in question.a. Failure of retest – immediately submit U, M,
L, and “all level” samples to third party lab. Requires lockdown of tank(s).
Sample / Test ProtocolSample / Test Protocol
5. Conductivity Testing (ASTM D-2624)
A. Field Test at Start of Pipeline Receipt or of Vessel Composite, and Tank Sample After1. Minimum Requirement – 50 pS/m
B. TMG Lab to test alsoC. Lubricity / Conductivity “Cocktail” used in certain terminals
Sample / Test ProtocolSample / Test Protocol6. Shipping
A. “Dangerous Goods In Excepted Quantities”1. Sample Size – 20 to 30 mL vials (500 ml total package)2. IATA Dangerous Goods Regulation3. Special Attention: Section 173.4 “Small Quantity
Exceptions”(Also labeling, documentation, packing requirements)
4. ESOH – FedEx Training Classes, Terminal Training, Certify Packing, etc.
5. $$ Savings – Huge – Gas Samples Especially6. Issues?? (Billing Errors, FedEx Pickup and local
knowledge of Regulation).A. 16 samples/$30 versus 4 samples/$100