In-Building Coverage Solution Aditya Kemang Village 090401 v1
-
Upload
trung-phan -
Category
Documents
-
view
182 -
download
4
Transcript of In-Building Coverage Solution Aditya Kemang Village 090401 v1
A Leading Provider for Smart Coverage and Enhancement Solutions for the Wireless Communication Industry Worldwide
In-Building Coverage with BTI’S FIDAS systemProposed Design forProposed Design for
Aditya kemang Village, Jakarta, IndonesiaAditya kemang Village, Jakarta, IndonesiaMarch, 2009
Fiber Intelligences Distribution Antenna System
Confidential
What is What is FIDASFIDAS InIn--Building Solution?Building Solution?Fiber Intelligences Distribution Antenna System
RF Signals are converted by Host Units (HU) into light Source and transported over fiber optical cables to the Remote units.
Light Signals are then converted back into RF signal by Remote Units (RU) units.
Single‐mode or Mutil Mode Fiber (to be requested) transmission for best performances
FIDAS can communicate up to 15km between HU and RU units.
RU to DAS System by existing Coaxial connections
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
BTIBTI’’s Solution s Solution –– FIDAS SystemFIDAS System
BTI’S proposed FIDAS system in‐building coverage solution for Aditya kemang Aditya kemang VillageVillage .
This is a hybrid DAS network system, a concept of maximizing existing passive antenna system in the building which need to upgrade or mix & match active and passive system for new buildings.
Achieved cost efficiency, fast & easy installation, flexibility and networks scalability.
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
FIDASFIDAS InIn--Building Coverage DesignBuilding Coverage Design
Aditya kemang VillageAditya kemang Village
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Proposed Concepts:Proposed Concepts:
The proposed In‐building Coverage design using BTI’SFIDAS system for Aditya kemang VillageAditya kemang Village , use the existing DAS system with 100% active system to transport operator’s BTS signaling to mobile users
The following presentation intend to provide an idea to introduce the FIDAS system for in‐building coverage ,which supports multi‐operators, multi‐bands and multi‐carriers wireless communication network services.
The figures used in this presentation to describe the buildings all come from third‐party. A professional site survey and sites study should be done before deploy the IBC implementation.
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Here is Here is AAdityaditya KKemangemang VVillageillage
Nos. of Building: Tower A,B,C,D,E,F,G, Parkia, Pengelola, V.K.Hotel, MALL,Sekolah,Dehan lantai Parkia, R.serbaguna
Nos. of Floors: Totally 298
Nos. of Basement 3
Coverage area : Around 224,074 m2
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
ZONE Description ZONE Description -------- Buildings DistributingBuildings Distributing
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Tower BTower B
PARKERPARKER
Tower CTower C
Tower ATower A
Tower DTower DPENGELOLAPENGELOLA
Tower ETower ETower FTower F
Tower GTower G
HOTELHOTEL
M A L L
SEKOLAH/LANTAIPARKIA
Confidential
277761248112BASEMENT 3
811441483168BASEMENT 2
811441483168BASEMENT 1
1R.SERBAGUNA
1167.012519.161.1TOWER G
1248213041.6TOWER F
1531.531869.322.1TOWER E
730.23772.310.1TOWER E
115264824SEKOLAH
1216.041870.717.2HOTEL
64009.540160DEHAN LANTAI PARKIA
12992556232K.V.MALL
817.4230.526.8PENGELOLA
11964132.536.8TOWER D
1139.844627.441.6TOWER C
916.324627.633.2TOWER B
1051.75324336.5728.76TOWER A
2452.166.531.677.6PARKIA
AREA per FLOORFLOORSW(M)L(M)BUILDINGS
Confidential
Operators BriefOperators Brief
There will be 3 band wireless network (3G, CDMA800, DCS1800) provided by 8 operators (Telkomsel, XL,Indosat,HCPT,NTS,FLEXI,ESIA,DCS1800).The total carries will be 12 currently in AdityaAditya kemangkemangVillage.Village.More carries will be used in future. The IBC system should be able to support the network expanding . 5DCS1800DCS1800
CDMA800ESIA2
CDMA800FLEXI
3GNTS
3GHCPT
3GINDOSAT
3GXL
5
3GTELKOMSEL
CARRIESCARRIESBANDOPERATORS/BRAND
Confidential
Coverage System OverviewCoverage System Overview
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Principle of the FIDAS solution DesignPrinciple of the FIDAS solution Design
Confidential
Principle of the FIDAS solution DesignPrinciple of the FIDAS solution Design
The is a multi –band wireless network.
The 3G(CDMA2000,WCDMA) signal has the lowest penetrate ability
In order to insure all bands Carries can be reached at a acceptable RX level in the buildings, take the 3G signal to be
calculate factors. The acceptable RX level of 3G set to be ‐85dbm
Confidential
Coverage ERP Calculations
The target average coverage RX ‐‐‐ ‐85dbm
Based on the space transmit model formula ‐‐‐‐Ls=32.45+20logR(Km)+20logF(MHz) ,we can calculate the coverage radius of 3G omni antenna RPo – Ls – L0 = P ‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐‐ (1 )Po: antenna output power ( Without antenna gain)
Based on the experience, the input power to omni antenna set to be ‐7dbm
Ls: Power loss in spaceL0: Power block in the building P: The target coverage RX
Principle of the IBC solution DesignPrinciple of the IBC solution Design
Confidential
5db ~ 8dbglass
3db ~ 6dbWooden furniture
3dbHuman body
30 dbLift
1db ~ 8dbTunnel in Ceiling
10db~ 15dbBeton & Concrete Floor
15db ~ 20dbBeton & Concrete wall
10db ~ 15dbNormal brick wall
LossMain Kind Material
Confidential
•Considering the building structure features, assume the LO to be 17 dbBring all the values needed into the formula (1 ) ‐7 – 32.45‐ 20logR ‐66.85 – 17 = ‐ 85R≈ 10 m, in order to a more flexible calculation , we set R= 8 m
•So the coverage area of 1 PCS omni antenna is 3.14*64 =200 m2
•And we can calculate the quantity of antennas each floor ,for instance, Floor 1 of Tower A is 1052 m2, the quantity of antenna is 1052/200 ≈ 6
Confidential
Principle of the IBC solution DesignPrinciple of the IBC solution Design
In order to make a effective coverage margin , we divide the whole Aditya Kemang Village into 3 zones.
Assume that there is one BTS house in each Zone. The BTS of operators located in the BTS house and provide 3 BAND ( 3G, cdma800, DCS1800 ) wireless signal and 12 carries in all.
Confidential
Block DiagramBlock Diagram
BTS GROUP 1 BTS GROUP 2 BTS GROUP 3
ZONE 1ZONE 1
ZONE 2ZONE 2
ZONE 3ZONE 3
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Zone 1Zone 11. Tower A
2. Tower B
3. Tower C
4. Tower D
5. PENGELOLA
ZONE Description ZONE Description
Zone 2Zone 21. Basement1
2. Basement2
3. Basement3
4. V.K.Mall
5. PARKIA
Zone 3Zone 31. DEHAN LANTAI
PARKIA
2. HOTEL
3. Tower E,F,G
4. R.serbaguna
5. SEKOLAH
BTS GROUP 1BTS GROUP 1 BTS GROUP 2BTS GROUP 2 BTS GROUP 3BTS GROUP 3
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
ZONE DescriptionZONE Description ---- Buildings DistributingBuildings Distributing
ZONE 1ZONE 1
ZONE 2ZONE 2
ZONE 3ZONE 3
Confidential
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Architecture of the FIDAS solutionArchitecture of the FIDAS solution
Confidential
Architecture of the FIDAS solutionArchitecture of the FIDAS solution
33024612TOTAL
923154BTS3Zone3
1361154BTS2Zone2
1018164BTS1Zone1
OMNI ANTENNARUHUBTSZONE
Confidential
32514MALL
851PARKIA
1391
2BASEMENT 3
40614BASEMENT 2
40614BASEMENT 1
ZONE2
361SEKOLAH
1501
3TOWER G
6R.SERBAGUNA
17213
TOWER E
1472TOWER F
1081
2HOTEL
30414DEHAN LANTAI PARKIA
ZONE3
24614TOWER D
27614TOWER C
23014TOWER B
8PENGELOLA
25814
TOWER A
ZONE1
OMNI ANTENNAHURUBUILDINGSZONE
Confidential
Block Diagram Block Diagram -------- ZONE 1ZONE 1
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Equipment list for ZONE 1Equipment list for ZONE 1
1018RU *16HU *4POI*1TOTAL
L31 ‐‐ L4166RU044
L21 ‐‐ L3060RU043
L11 ‐‐ L2060RU042Tower D
L1‐‐ L10 60RU041
HU04*1
L35 ‐‐ L4672RU034
L23 ‐‐ L3472RU033
L11 ‐‐ L2272RU032Tower C
L1‐‐ L10 60RU031
HU03*1
L35 ‐‐ L4660RU024
L23 ‐‐ L3460RU023
L11 ‐‐ L2260RU022Tower B
L1‐‐ L10 50RU021
HU02*1
L34 ‐‐ L4360RU014
L23 ‐‐ L3366RU013
L12 ‐‐ L2266RU012Tower A
L1‐‐ L11 66
PENGELOLAL1 ‐‐ L28RU011
HU01*1
POI*1ZONE 1
Coverage AreaEstimated Antenna
EquipmentsZONE
Confidential
Block Diagram Block Diagram -------- ZONE 2ZONE 2
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Equipment list for ZONE 2Equipment list for ZONE 2
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
1361RU *15HU *4POI*1TOTAL
L4 ‐‐ L5130RU084
L365RU083
L265RU082V.K.MALL
L165RU081
HU08*1
PARIKA85RU073
RU072BASEMENT 3139
RU071
HU07*1
RU064
RU063
RU062BASEMENT 2406
RU061
HU06*1
RU054
RU053
RU052BASEMENT 1406
RU051
HU05*1
POI*1ZONE 2
Coverage AreaEstimated Antenna
EquipmentsZONE
Confidential
Block Diagram Block Diagram -------- ZONE 3ZONE 3
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Equipment list for ZONE 3Equipment list for ZONE 3
923RU *15HU *4POI*1TOTAL
SEKOLAHL1 ‐‐ L636RU124
L17 ‐‐ L2554RU123
L9 ‐‐ L1648RU122 TOWER G
L1 ‐‐ L848RU121
HU12 * 1
L17 ‐‐ L2572RU113
L8 ‐‐ L1672RU112 TOWER E
L1 ‐‐ L728
R.SERBAGUNAL16RU111
HU11 *1
L12 ‐‐ L2170RU104TOWER F
L1 ‐‐ L1177RU103
L11 ‐‐ L1848RU102HOTEL
L1 ‐‐ L1060RU101
HU10*1
P15 ‐‐ F1980RU094
P11 ‐‐ P1464RU093
P5 ‐‐ P1096RU092DEHAN LANTAI PARKIA
P1 ‐‐ P464RU091
HU09*1
POI*1ZONE 3
Coverage AreaEstimated Antenna
EquipmentsZONE
Confidential
Block DiagramBlock Diagram
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
OMNI Antenna LocationOMNI Antenna Location
Confidential
85136.531.677.6PARKIA
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
25864336.5728.76TOWER A
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
23054627.633.2TOWER B
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
23054627.633.2TOWER C
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
24664132.536.8TOWER D
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
84230.526.8PENGELOLA
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
32565556232MALL
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
65 PCS
Confidential
304329.540160DEHAN LANTAI
PARKIA
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
10861870.717.2HOTEL
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
36664824SEKOLAH
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
284772.310.1TOWER E
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
14481869.322.1TOWER E
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
1477213041.6TOWER F
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
15062519.161.1TOWER G
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
4064061483168BASEMENT 1
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
406 PCS
Confidential
406 PCS
4064061483168BASEMENT 2
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
139 PCS
1391391248112BASEMENT 3
QUANTITY IN ALL
QUANTITY PER FLOOR
FLOORSW(M)L(M)BUILDINGS
Confidential
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Management NetworkManagement Network
Confidential
Management NetworkManagement Network
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Comprehensive System ManagementComprehensive System Management
OptionalMap view
Device info
Remote control & management via LAN or external dial-up modem
OptionalAPI for 3rd parties applicationsOptionalSummary dry contact
Troubleshooting
Summary minor alarms
OptionalWeb based client
Device mapping
Summary major alarms
Client/Server based remote supervision (NMS)
GUI based local management (EMS)
Visual Alarm LED
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Aims:Aims:--
BTI’S FIDAS Coverage Solution aims to provides
• cost efficiency, fast & easy installation
• flexibility and scalability
• Supports multi‐band, multi‐system, multi‐carrier and multi‐operator
• Hybrid System able to work with both Active and Passive
components
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.
Confidential
Proposed byHead office
Bravo Tech Inc.6185 Phyllis Dr. Unit D. Cypress, CA 90630, USA
Tel: +1 (714)2308333 FAX: +1 (714)230‐8341
www.bravotechinc.com
APAC Sales and Service office
Bravo Technologies (S) Pte Ltd.Blk261, Waterloo Center, #02‐06, Waterloo Street,
Singapore 180261
Tel: +65‐63372018 FAX: +65‐63360328
www.bravotechinc.com
Note: Information and Material in this presentation is proprietary to BTI Group of Companies, Unauthorized Copying or Use of Information and Material from this presentation without written permission from BTI will be considered unlawful and BTI reserved the right to request compensation and unauthorized user will be dealt with under the law of Singapore. BTI reserved the right to amend or made changes to the above information without prior advice.