IMPLANTOLOGY - Dynamic Abutment Solutions EN€¦ · has revolutionized the implantology sector,...
Transcript of IMPLANTOLOGY - Dynamic Abutment Solutions EN€¦ · has revolutionized the implantology sector,...
-
IMPLANTOLOGY
-
2
*Approval of total quality system assurance by notified body, according
to Community legislation, for sterile and medical devices Class IIa.
NOTE
-
3
4 DYNAMIC ABUTMENTS®
6 ASTRA TECH / AQUA / LILAC
7 NOBEL BIOCARE / BRANEMARK SYSTEM
8 NOBEL BIOCARE / MULTI-UNIT / STANDARD
9 NOBEL BIOCARE / REPLACE
10 NOBEL BIOCARE / ACTIVE
11 STRAUMANN / INTERNAL OCTOGON / SYNOCTA / BONE LEVEL
12 ECKERMANN / ALL-SPIRAL / DUPLO
13 BIOMET 3I / CERTAIN
14 BIOMET 3I / OSSEOTITE
15 BTI / INTERNAL CONNECTION
16 BTI / EXTERNAL CONNECTION
17 ZIMMER / SCREW-VENT
18 KLOCKNER / NK2-SK2 / ESSENTIAL CONE
19 PHIBO AND ANKYLOS
20 DIO IMPLANT/ SM SYSTEM
21 TEMPORAL 20º DYNAMIC ABUTMENT® OF PEEK
22 DYNAMIC ABUTMENT® CONOMETRY / ANALYZER
23 3.0 DYNAMIC ABUTMENT® SYSTEM FOR CAD-CAM
24 3.0 DYNAMIC TITANIUM BASES AND SCAN BODY
25 SYSTEM TORQUE
26 ACCESSORIES / PROSTHETIC REAMER
27 DEFINITIONS / INDICATIONS
28 3.0 DYNAMIC ABUTMENT® SCREWS
29 STRAIGHT ABUTMENT SCREWS
30 GUARANTEE
31 CONTACT
INDEX
-
4
3.0 DYNAMIC ABUTMENTS®
3.0 Dynamic Abutment® is an innovative solution which incorporates freedom of movement from 0º to 28º, to rectify angulation issues. It simplifies the prosthetic work, and most importantly, provides solutions.
The 3.0 Dynamic Abutment® system is a unique and exclusive piece that has revolutionized the implantology sector, and it is the true alternative to titanium angulated abutments and to individual dies made by the technician. It is made up of two pieces connected together by an elbow that works as a joint, while the chimney pivots on the semi-spherical base. The Dynamic Abutment® system can rectify any angulation issues with millimetric precision up to 28º with full freedom of movement.
REASONS FOR USING 3.0 DYNAMIC ABUTMENT®
28º ANGUlATION FREEDOM
Resolve angulation problems
Improve the restoration function
The function improves when applying the 3.0
Dynamic Abutment® which allows for the anatomically reconstruction of the piece.
Screwed final prosthesis
-
5
3.0 DYNAMIC ABUTMENT®
Improve the aesthetics:
Added thickness of ceramics
Lack of space is a usual problem to place ceramics
It can be resolvedby applying the 3.0Dynamic Abutment®
No vestibular metallic edge
Aesthetics problems in angulated solutions
Ceramic grows from the implant applying 3.0 Dynamic Abutment®
Cost reduction
Speed
Simplicity
Application of 3.0 Dynamic Abutment® system in milled structures
Correcting the screw output up to 30° with a more aesthetic finish.
VIDEO3.0 DYNAMIC ABUTMENT®
-
6
COMPATIBlE WITH ASTRA TECHAQUA / lIlAC
*See pag. 2
TCOLBTCO15 N·cm
TPDH1415 N·cm
COMPLEMENTS
45º C
ON
IC
3,5 - 4,0/4,5-5,0
ASTS45/T PCASTS45/P
PD3ASTS45/T PD3ASTS45/P
CLDES 1.20
DSPDCLH-18/24/32PD: 18/24/32 mm
RAST45
TCOLBTCO15 N·cm
COMPLEMENTS
TPDH1415 N·cm
20º C
ON
IC
3,5 - 4,0/4,5-5,0
ASTS20/T PCASTS20/P
PD3ASTS20/T PD3ASTS20/P
CLDES 1.20
DSPDCLH-18/24/32PD: 18/24/32 mm
RAST20
4,5 - 5
TAST2LBTAST230 N·cm RASTWP
WID
E PL
ATFO
RM
ASTHWP/T PCASTHWP/P
COMPLEMENTS
3,5 - 4
ASTHRP/T PCASTHRP/P
PD3ASTRRP/PPD3ASTHRP/CC
TAST16LBTAST1620 N·cm RASTRP
COMPLEMENTS
REG
ULAR
PLA
TFO
RM
TPDH16L7620 N·cm DSPDCLH-18/24/32
PD: 18/24/32 mm
-
7
COMPATIBlE WITH NOBEl BIOCAREBRANEMARK SYSTEM
*See pag. 2
COMPLEMENTS
0,7
0,7
3,4
5,1
CLDES 1.30PCUCH51/PPCUCS51/P
UCS51/T
PD3UCH51/TPD3UCS51/T
PD3UCH51/CCPD3UCS51/CC
PD3UCH51/PPD3UCS51/P
TUC25LBTUC2530 N·cm
TPDH2525 N·cm
TPDH25L6725 N·cm
RUC51
WID
E PL
ATFO
RM
DSPDCLH-18/24/32PD: 18/24/32 mm
COMPLEMENTS
4,1
0,7
0,7
2,7
CLDES 1.20CBS41/TPHECAL
PROCALUCH41/TUCS41/T
PD3UCH41/TPD3UCS41/T
PD3UCH41/CCPD3UCS41/CC
PD3UCH41/PPD3UCS41/P
TUCLBTUC30 N·cm
TPDH225 N·cm
TPDH2L620 N·cm
RUC41 REG
ULAR
PLA
TFO
RM
DSPDCLH-18/24/32PD: 18/24/32 mm
COMPLEMENTS
0,7
0,7
2,4
3,5
UCS35/T CLDES 1.30PCUCH35/PPCUCS35/P
PD3UCH35/TPD3UCS35/T
PD3UCH35/CCPD3UCS35/CC
PD3UCH35/PPD3UCS35/P
TUC16LBTUC1620 N·cm
TPDH1620 N·cm
TPDH16L620 N·cm
RUC35 NAR
ROW
PLA
TFO
RM
DSPDCLH-18/24/32PD: 18/24/32 mm
-
8
COMPATIBlE WITH NOBEl BIOCARE
MUlTI-UNIT
STANDARD
TSTLBTST15 N·cm
REG
ULAR
PLA
TFO
RM
0,8
4,1
2
DSPDCLH-18/24/32PD: 18/24/32 mm
CLDES 1.20PST41/T
PD3ST41/T PD3ST41/P
TPDHST15 N·cm
TPDH1825 N·cmW
IDE
PLAT
FORM
6
DSPDCLH-18/24/32PD: 18/24/32 mm
PD3CO51/P
TPDH1415 N·cm
TCOLBTCO15 N·cm
PD3CO41/T PD3CO41/CC PD3CO41/P
COMPLEMENTS
REG
ULAR
PLA
TFO
RM
4,8
CO41/T PCOCAL TIT-CO41-PRVCLDES 1.20
DSPDCLH-18/24/32PD: 18/24/32 mm
RMU48
*See pag. 2
-
9
COMPATIBlE WITH NOBEl BIOCARE REPlACE
COMPLEMENTS
5,0CLDES 1.30RPLT50/T PCRPLT50/P RPLR50/T PCRPLR50/P
TRPLLBTRPL30 N·cm RRPL50
WID
E PL
ATFO
RM
*See pag. 2
COMPLEMENTS
COMPLEMENTS
3,5
RPLT35/T
PD3UCH35BT/TPD3UCS35BT/T
PD3UCH35BT/CC PD3UCS35BT/CC
PD3UCH35BT/PPD3UCS35BT/P
REBNP16 PIMEBNP16 TAPEB/PK
PCRPLR35/P CLDES 1.30PCRPLT35/P RPLR35/T
PD3RPLR35/PPD3RPLT35/CC
TRPL35LBTRPL3525 N·cm
TPDH1620 N·cm
EBRPLNP25 N·cm
TPDH18L7525 N·cm
RRPL35
NAR
ROW
PLA
TFO
RM
DSPDCLH-18/24/32 PD: 18/24/32 mm
DSEBNP:25mm
COMPLEMENTS
COMPLEMENTS
RPLT43/T
REBRP18 PIMEBRP18 TAPEB/PK
PCRPLR43/PCLDES 1.30
PCRPLT43/P RPLR43/T
PD3UCH41/TPD3UCS41/T
PD3RPLT43/CC** PD3RPLR43/P** **Angulation up to 20º
PD3UCH41/CC PD3UCS41/CC
PD3UCH41/PPD3UCS41/P
TRPLLBTRPL30 N·cm
TPDH1825 N·cm
TPDH2L8225 N·cm
EBRPLRP30 N·cm
RRPL43
DSPDCLH-18/24/32 PD: 18/24/32 mm
DSEBRP:25 mm
4,3
REG
ULAR
PLA
TFO
RM
Internal PD3.0: Divergence angle between implants up to 20°With convertor: Divergence angle between implants up to 26°
-
10
COMPATIBlE WITH NOBEl BIOCARE
*See pag. 2
TPDH16L7320 N·cm
PD3ACTHNP/CC PD3ACTRNP/PDSPDCLH-18/24/32PD: 18/24/32 mm
NAR
ROW
PLA
TFO
RM
TPDH2L7525 N·cm
PD3ACTHRP/CC PD3ACTRRP/PDSPDCLH-18/24/32PD: 18/24/32 mm
REG
ULAR
PLA
TFO
RM
ACTIVE
-
11
INTERNAl OCTOGON
COMPATIBlE WITH STRAUMANN
SYNOCTA
COMPLEMENTS
TPDH2L525 N·cm
EBSYN30 N·cm
TSYN48LBTSYN4830 N·cm
REG
ULAR
PLA
TFO
RM
4,8
3
1,47
CO48/TCR48/T
PD3CO48/TPD3CR48/T
PD3CO48/PPD3CR48/P
PCSYO48/PPCSYR48/P
DESLCTORX:25mm
CLDES 1.30
DSPDCLH-18/24/32PD: 18/24/32 mm
RSY48
COMPLEMENTS
TOCTLBTOCT30 N·cm
REG
ULAR
PLA
TFO
RM
4,8
POCO48/T POCR48/TPCOCO48/P PCOCR48/P ROC48CLDES 1.30
*See pag. 2
BONE lEVEl
PD3BONHNP/CC PD3BONRNP/P
TPDH16L7820 N·cm
NAR
ROW
PLA
TFO
RM
DSPDCLH-18/24/32PD: 18/24/32 mm
PD3BONHRP/CC PD3BONRRP/P
TPDH16L7820 N·cm
REG
ULAR
PLA
TFO
RM
DSPDCLH-18/24/32PD: 18/24/32 mm
-
12
All-SPIRAl
DUPlO
4,56
CLDES 1.25ECKDUC/T ECKDUR/TTECKDU125LBTECKDU12525 N·cmRE
GUL
AR P
LATF
ORM
DSPDCLH-18/24/32PD: 18/24/32 mm
4,56
3,0
2,3
CLDES 1.25ECKALLC/TECKALLR/T
PD3ECKALLC/T PD3ECKALLR/T
TECKALL125LBTECKALL12525 N·cm
TPDH18L4825 N·cm
REG
ULAR
PLA
TFO
RMCOMPATIBlE WITH ECKERMANN
*See pag. 2
-
13
COMPATIBlE WITH BIOMET 3I
*See pag. 2
COMPLEMENTS
T3ILBT3I20 N·cm W
IDE
PLAT
FORM
5,0
3IINTRWP/T PC3IINTHWP/PPC3IINTRWP/P R3IINT50
CLDES 1.30
CERTAIN
TPDH1620 N·cm
TPDH16L8420 N·cm
EB3IRP25 N·cm
T3ILBT3I20 N·cm
REG
ULAR
PLA
TFO
RM
4,0
3IINTH/T3IINTR/T
PD3UCH41/TPD3UCS41/T
PD3IRRP/PPD3IHRP/CC
PD3UCH41/CCPD3UCS41/CC
PD3UCH41/PPD3UCS41/P
PC3IINTHRP/PPC3IINTRRP/P
DSEBRP:25mm
CLDES 1.30
DSPDCLH-18/24/32PD: 18/24/32 mm
REBRP16 PIMEBRP16 TAPEB/PK
R3IINT40
COMPLEMENTS
COMPLEMENTS
Internal PD3.0: Divergence angle between implants up to 18°With convertor: Divergence angle between implants up to 26°
-
14
COMPATIBlE WITH BIOMET 3IOSSEOTITE
COMPLEMENTS
DSPDCLH-18/24/32PD: 18/24/32 mm
5,0
2,7
0,7
CLDES 1.20
RUC50
UCS50/T PCUCH50/PPCUCS50/P
PD3UCH5O/T PD3UCS5O/T
PD3UCH5O/P PD3UCS5O/P
TUCLBTUC30 N·cm
TPDH225 N·cm
WID
E PL
ATFO
RM
COMPLEMENTS
DSPDCLH-18/24/32PD: 18/24/32 mm
4,1
0,7
0,7
2,7
CLDES 1.20CBS41/T
RUC41
UCH41/TUCS41/T
PHECALPROCAL
PD3UCH41/T PD3UCS41/T
PD3UCH41/CC PD3UCS41/CC
PD3UCH41/P PD3UCS41/P
TUCLBTUC30 N·cm
TPDH225 N·cm
TPDH2L625 N·cm
REG
ULAR
PLA
TFO
RM
COMPLEMENTS
TPDH2L6525 N·cm DSPDCLH-18/24/32
PD: 18/24/32 mm3,3
2,5
0,7
0,7
CLDES 1.20
RUC33
UCS33/T
PD3UCH33/T PD3UCS33/T
PD3UCH33/P PD3UCS33/P
PCUCH33/P PCUCS33/P
TUCLBTUC30 N·cm
TPDH225 N·cmN
ARRO
W P
LATF
ORM
*See pag. 2
-
15
COMPATIBlE WITH BTIINTERNAl CONNECTION
*See pag. 2
COMPLEMENTS
TBTILBTBTI25 N·cm
WID
E PL
ATFO
RM5,5
BTIINTRWP/T PCBTIINTHWP/PPCBTIINTRWP/P
RBT55CLDES 1.30
TPDH1620 N·cm
TPDH18L7525 N·cm
EBBTIRP25 N·cm
TBTILBTBTI25 N·cm
REG
ULAR
PLA
TFO
RM
4,1
BTIINTH/T
PD3UCH41/TPD3UCS41/T
PD3BTIIRRP/PPD3BTIHRP/CC
PD3UCH41/CCPD3UCS41/CC
PD3UCH41/P PD3UCS41/P
PCBTIINTHRP/P PCBTIINTRRP/PBTIINTR/T
DSEBRP: 25mm
CLDES 1.30
DSPDCLH-18/24/32PD: 18/24/32 mm
REBRP16 PIMEBRP16 TAPEB/PK
RBT41
COMPLEMENTS
COMPLEMENTS
Internal PD3.0: Divergence angle between implants up to 18° With convertor: Divergence angle between implants up to 26°
-
16
COMPATIBlE WITH BTIEXTERNAl CONNECTION
COMPLEMENTS
DSPDCLH-18/24/32PD: 18/24/32 mm
5,5
3,3
1,1
CLDES 1.30
RUC55
UCS55/T PCUCH55/PPCUCS55/P
PD3UCH55/TPD3UCS55/T
PD3UCH55/P PD3UCS55/P
TSYN48LBTSYN4830 N·cm
TPDH2L625 N·cm
WID
E PL
ATFO
RM
COMPLEMENTS
DSPDCLH-18/24/32PD: 18/24/32 mm
4,1
0,7
0,7
2,7
CLDES 1.20
CBS41/T
RUC41
UCH41/TUCS41/T
PHECALPROCAL
PD3UCH41/T PD3UCS41/T
PD3UCH41/CC PD3UCS41/CC
PD3UCH41/P PD3UCS41/P
TUCLBTUC30 N·cm
TPDH225 N·cm
TPDH2L625 N·cm
REG
ULAR
PLA
TFO
RM
COMPLEMENTS
DSPDCLH-18/24/32PD: 18/24/32 mm
CLDES 1.30
3,5
2,5
1,1
1,1
RUC35BT
UCS35BT/T
PD3UCH35BT/T PD3UCS35BT/T
PD3UCH35BT/CC PD3UCS35BT/CC
PD3UCH35BT/P PD3UCS35BT/P
PCUCH35BT/P PCUCS35BT/P
TSYN48LBTSYN4830 N·cm
TPDH225 N·cm
TPDH2L5125 N·cm
NAR
ROW
PLA
TFO
RM
*See pag. 2
-
17
COMPATIBlE WITH ZIMMERSCREW-VENT
*See pag. 2
TZIMLBTZIM25 N·cm W
IDE
PLAT
FORM
5,7
PZIM57/T PCZIMH57/PPCZIMR57/P
RZIM57CLDES 1.30
COMPLEMENTS
TAPEB/PK
COMPLEMENTS
TZIMLBTZIM25 N·cm
TZIML76LBTZIML7625 N·cm
TPDH1825 N·cm
EBZIMNP30 N·cm
NAR
ROW
PLA
TFO
RM
3,5
DSPDCLH-18/24/32PD: 18/24/32 mm
CLDES1.30
CLDES1.25
DSEBNP:25mm
RZIM35
REBNP18 PIMEBNP18
PZIM35/T PCZIMR35/P PCZIMH35/P
PD3UCH35BT/TPD3UCS35BT/T
PD3UCH35BT/CC PD3UCS35BT/CC
PD3UCH35BT/PPD3UCS35BT/P
PD3ZIMRNP/PPD3ZIMHNP/CC
TPDH17L7125 N·cm
COMPLEMENTS
TPDH1825 N·cm
TPDH17L7120 N·cm
EBZIMRP30 N·cm
TZIMLBTZIM25 N·cm
REG
ULAR
PLA
TFO
RM
4,5
PZIM45/T
PD3UCH41/TPD3UCS41/T
PD3ZIMRRP/PPD3ZIMHRP/CC
PD3UCH41/CCPD3UCS41/CC
PD3UCH41/P PD3UCS41/P
PCZIMH45/PPCZIMR45/P
DSEBRP: 25mm
CLDES 1.30
DSPDCLH-18/24/32PD: 18/24/32 mm REBRP18 PIMEBRP18
TAPEB/PK
RZIM45
COMPLEMENTS
COMPLEMENTS
Internal PD3.0: Divergence angle between implants up to 10°With convertor: Divergence angle between implants up to 26°
-
18
COMPATIBlE WITH KlOCKNER
NK2-SK2
ESSENTIAl CONE
DSPDCLH-18/24/32PD: 18/24/32 mm
4,2
3,0
1,8
KLH42/TKLS42/T
PD3KLH42/T PD3KLS42/T
PD3KLS42/P
TKLLBTKL25 N·cm
TPDH1825 N·cm
REG
ULAR
PLA
TFO
RM
DSPDCLH-18/24/32PD: 18/24/32 mm
4,5
CLDES 1.30KLSSH45/T KLSSR45/T
PD3KLSSH45/T PD3KLSSR45/T
PD3KLSSR45/P
TRPL35LBTRPL3525 N·cm
TPDH18L4825 N·cm
REG
ULAR
PLA
TFO
RM
6,0
CLDES 1.30KLSSR6/TTRPL35LBTRPL3525 N·cm
WID
E PL
ATFO
RM
*See pag. 2
Compatible with 12º Octacone
-
19
COMPATIBlE WITH PHIBO AND ANKYlOS
PHIBO
*See pag. 2
ANKYlOS
TPDH16L7620 N·cm
TSA
SERI
E 3
3,7
PD3PHIHNP/T PD3PHIRNP/PRPHINPDSPDCLH-18/24/32
PD: 18/24/32 mm
COMPLEMENTS
TPDH18L7525 N·cm
TSA
SERI
E 4
4,7PD3PHIHRP/T PD3PHIRRP/P
RPHIRPDSPDCLH-18/24/32PD: 18/24/32 mm
COMPLEMENTS
TPDH1620 N·cm
EBANK1525 N·cm
EBANK3025 N·cm
NAR
ROW
/ R
EGUL
AR /
WID
E PL
ATFO
RM
3,5 - 4,5 /5,5 - 7 DSPDCLH-18/24/32
PD: 18/24/32 mm
REBNP16 PIMEBNP16 TAPEB/PK
PD3UCH35BT/T PD3UCH35BT/PPD3UCH35BT/CC
PD3UCS35BT/T PD3UCS35BT/PPD3UCS35BT/CC
DSEBRP: 25mm
COMPLEMENTS
-
20
COMPATIBlE WITH DIO® IMPlANT
DIO SM SYSTEM
TPDH18L7525 N·cm
3,8 - 4,1
PD3DIOHNP/TPD3DIORNP/T
PD3DIOHNP/CCPD3DIORNP/CC
PD3DIORNP/PDSPDCLH-18/24/32PD: 18/24/32 mmN
ARRO
W P
LATF
ORM
TPDH2L7425 N·cm
4,5 - 5,0 - 5,3
PD3DIOHRP/TPD3DIORRP/T
PD3DIOHRP/CCPD3DIORRP/CC
PD3DIORRP/PDSPDCLH-18/24/32PD: 18/24/32 mmRE
GUL
AR P
LATF
ORM
WID
E PL
ATFO
RM
*See pag. 2
-
21
TEMPORARY 20° DYNAMIC ABUTMENT® OF PEEK
The PEEK temporary abutments allow the immediate provisional elaboration of prostheses and restorations over implants.Through its base of PEEK, they are screwed directly on the implant being useful as base for a direct investment.The PEEK temporary abutments can be used either in dental office or laboratory.Note: Do not use it for casting.
COMPATIBlE WITH BRANEMARK SYSTEM
4,1
2,7
0,7
PDUCS41/PKTPDH2L625 N·cm RE
GUL
AR P
LATF
ORM
DSPDCLH-18/24/32PD: 18/24/32 mm
COMPATIBlE WITH STRAUMANN SYNOCTA
4,8
3
1,47
PDCR48/PK
TPDH2L625 N·cm RE
GUL
AR P
LATF
ORM
DSPDCLH-18/24/32PD: 18/24/32 mm
4,8
PDCO41/PK
TPDH14L5215 N·cm
REG
ULAR
PLA
TFO
RMCOMPATIBlE WITH MUlTI-UNIT
DSPDCLH-18/24/32PD: 18/24/32 mm
*See pag. 2
-
22
CONOMETRY DYNAMIC ABUTMENT®
20° DYNAMIC ABUTMENT® ANAlYZER
ANPD16/PK ANPD18/PK ANPD20/PKANPD14/PK
Set of 4 analyzer of the Dynamic Abutment® system made of PEEK, classified by metric, sterilizable, and compatible with most of the implants on the market. It allows an easy and quickly verification, either in
the dental office or laboratory, to detect if the Dynamic Abutment® system will correct the aesthetic and functional problem.
*See pag. 2
TPDH225 N·cm
PDUCH41C0/T
Dynamic Abutment® with a milled die at 6º, indicated for over dentures and bridges.
-
23
3.0 DYNAMIC ABUTMENT® SYSTEMFOR CAD-CAM MIllED STRUCTURES
DYN
AMIC
ABU
TMEN
T SC
REW
S 30
º
COMPATIBIlITY TABlE
*See pag. 2
TPDHST 15 N·cm
TPDH25L67 25 N·cm
TPDH16L78 20 N·cm
TPDH14L52 15 N·cm
TPDH16 20 N·cm
TPDH16L73 20 N·cm
TPDH16L76 20 N·cm
TPDH14L39 15 N·cm
TPDH14 15 N·cm
TPDH16L6 20 N·cm
TPDH2L5 25 N·cm
TPDH2L51 25 N·cm
25 N·cmTPDH18
TPDH18L48 25 N·cm
TPDH18L75 25 N·cm
TPDH2 25 N·cm
TPDH17L71 25 N·cm
TPDH16L84 20 N·cm
TPDH18L65 25 N·cm
TPDH25 25 N·cm
TPDH2L67 25 N·cm
25 N·cmTPDH2L74
TPDH2L82 25 N·cm
TPDH2L90 25 N·cm
TPDH2L65 25 N·cm
TPDH2L6 25 N·cm
TPDH2L75 25 N·cm
DSPDCLH-18/24/32PD: 18/24/32 mm
-
24
3.0 DYNAMIC TITANIUM BASES AND SCAN BODYTO ANGUlATE IN CAD-CAM
*See pag. 2
COMPATIBlE WITH
BRANEMARKTPDH2L6IND3UCS41/TiAIND3UCH41/TiA
COMPATIBlE WITH
MUlTIUNITTPDH14L39IND3CO41/TiA
COMPATIBlE WITH
REPlACETPDH2L90IND3RPLR43/TiAIND3RPLT43/TiA
COMPATIBlE WITH
STRAUMANN TPDH2L67IND3OCR48/TiAIND3OCO48/TiA
COMPATIBlE WITH BTI TPDH18L65IND3BTIRRP/TiAIND3BTIHRP/TiA
COMPATIBlE WITH
ZIMMER TPDH17L71IND3ZIMR45/TiAIND3ZIMH45/TiA
COMPATIBlE WITH DIO®
TPDH2L74IND3DIORRP/TiAIND3DIOHRP/TiA
COMPATIBlE WITH
NOBEl ACTIVE TPDH2L75IND3ACTRRP/TiAIND3ACTHRP/TiA
SCANBODY SBIND3OCRP/PKSBIND3RP/PKSBIND3MURP/PK
Compatible with Multi-Unit Rest of compatibilities Compatible with Straumann
REG
ULAR
PL
ATFO
RMRE
GUL
AR
PLAT
FORM
REG
ULAR
PL
ATFO
RMRE
GUL
AR
PLAT
FORM
REG
ULAR
PL
ATFO
RMRE
GUL
AR
PLAT
FORM
REG
ULAR
/W
IDE
PLAT
FORM
REG
ULAR
PL
ATFO
RM
-
25
SYSTEM TORQUE
SCREWDRIVERS
MACHINED ABUTMENTS
HEXAGON 1.20mmCLDES 1.20
SQUARE 1.30mmCLDES 1.30
HEXAGON 1.25mmCLDES 1.25
DESLCTORX: 25mm
HEXAGON 1.50mmCLDES 1.50
DYNAMIC ABUTMENTS
HEXALOBULAR 1.70 mmDSPDCLH-18: PD 18mm
SCREWDRIVER EB NPDSEBNP: 25mm
HEXALOBULAR 1.70 mmDSPDCLH-24: PD 24mm
SCREWDRIVER EB RP DSEB: 25mm / DSEBRP: 25mm
HEXALOBULAR 1.70 mmDSPDCLH-32: PD 32mm
ADAPTOR TORQUE WRENCH
MANUAL TORQUE WRENCH ADAPTER PROSTHETICMNADPCA
UNIVERSAL MANUAL TORQUE WRENCH PROSTHETICCCUNI
MANUAl HANDlE
LARGE MANUAL HANDLE FOR LABORATORYMNLB
MANUAL HANDLE FOR CLINICMNCL80
-
26
ACCESSORIES
PROSTHETIC REAMER
CHIMNEY REAMER
BASE REAMER
The casting process of the castable cylinders generates imperfections in the final metallic structure. In order to minimize the consequences generated by these process, Talladium have designed a new line of tools to correct the base of the cylinder, improving the interior of the chimneys and the adjustment on implant.
Set of handle and reamerPESC
ESXRP
ESADNPMNES. Handle for reamer
ESADRP
ESCIM
ESADWP
-
27
DEFINITIONS / INDICATIONS
Castable Straight Abutment: Abutment made of plastic.
Cast-to Straight Abutment in a Tilite milled base: Abutment with a Tilite base and castable chimney. Must be cast in Tilite alloy.
Cast-to 3.0 Dynamic Abutment® with a Tilite milled base: Abutment which can be angled up to 28° to correct angles on implants placed in an incorrect position. With a Tilite base and must be cast in Tilite alloy. The maximum angulation can only be reached in the milled area. In NP up to a maximum of 25° and the rest of platforms to a maximum of 28°.
Castable 3.0 Dynamic Abutment®: Fully castable abutment, to correct angulations on implants placed incorrectly. Can be angled up to 28°. The maximum angulation can only be reached in the milled area. In NP up to a maximum of 25° and the rest of platforms to a maximum of 28°.
Cast-to 3.0 Dynamic Abutment® with a Cobalt-chrome milled base: Abutment which can be angled up to 28° to correct angles on implants placed in an incorrect position. With a Cobalt-chrome base and must be cast in Cobalt-chrome alloy. The maximum angulation can only be reached in the milled area. In NP up to a maximum of 25° and the rest of platforms to a maximum of 28°.
Conometry Dynamic Abutment®: Dynamic Abutment® with a milled die at 6°, indicated foro ver dentures and bridges.
PEEK temporary Dynamic Abutment®: Allows the immediate provisional elaboration of prostheses and restorations over implants. Do not use it for casting.
Convertor 3.0 Dynamic Abutment®: Component within the Dynamic Abutment® System, made in Titanium, used to transform an internal connection to an external connection.
Tilite Cylinder (CBS41): Cylinder in Tilite for use with Implant Bars
Healing Cap EB (TAPEB): Healing of cicatrisation, only for EB.
Titanium temporary abutment: Titanium abutment with retentions for the manufacturing of Titanium structures over implants.
Clinical Screw: Titanium screw for the final fixture in patient’s mouth
laboratory Screws: Titanium screw for the prosthesis manufacture, for use only in the laboratory.
Square screwdriver: Screwdriver with square head of 1,30 mm.
Hexagonal Screwdriver: Screwdriver with an hexagonal head of 1,20 - 1,25 - 1,50 mm.
Dynamic 3.0 Abutment Screwdriver®: Screwdriver with ball shaped hexagonal head, exclusively for the 3.0 Dynamic Abutment® system.
EB Screwdriver for 3.0 Dynamic Abutment®: The convertor´s Screwdriver for the Dynamic Abutment® system.
Clinic Handle: Short stainless steel screwdriver handle for the dental surgeon.
laboratory Handle: Long stainless steel screwdriver handle for laboratory use.
Universal Manual Torque: Dynamometric manual torque wrench to tighten the clinical screws to the required Newtons.
Manual Torque Adapter: Component that locates in the Universal Manual Torque´s connection (square), into which the screwdriver top is fitted.
Replica: Implant replica made of stainless steel.
Impression taking: Piece to take indirect impression over implants or converters.
Analyzer: Dynamic Abutment® system analyzer, classified by metrics, allows verifying the angulation from 0 to 20 degrees of the implant.
Reamer: Corrects the base of the cylinder, improving the adjustment over the implant and the interior of the chimneys.
3.0 Dynamic Titanium Bases: Dynamic Titanium bases to angulate in cad /cam. Allows the correction of bad positioned implant.
Scan Body: Scannable PEEK Base to reproduce the virtual position and orientation of the 3.0 Dynamic Titanium base in 3D
-
28
REFE
REN
CE
MET
RIC
TORQ
UE
TOTA
L LE
NG
TH
THRE
AD L
ENG
TH
HEAD
DIA
MET
ER
A LE
NG
TH
B LE
NG
TH
C LE
NG
TH
SETT
LEM
ENT
ANG
LE
THRE
AD E
NTR
Y
CON
NEC
TIO
N
1,4 15 N·cm 3,9 1,8 2,4 2,1 - 1,8 straight - 45º chamfer
Hexalobular 1,70
1,4 15 N·cm 4 1,85 2,3 2 2,78 1,22 conical 30º 45º chamfer
1,4 15 N·cm 4,5 2,3 2,3 2,5 3,28 1,22 conical 30º 45º chamfer
1,4 15 N·cm 5,2 2,9 2,3 3,4 - 1,8 straight - 45º chamfer
1,6 20 N·cm 4,4 2,5 2,3 2,9 - 1,5 straight - Semi-sphere
1,6 20 N·cm 5,9 3 2,3 4,4 - 1,5 straight - Semi-sphere
1,6 20 N·cm 7,3 2,2 2,3 4,87 5,56 1,74 conical 35º 45º chamfer
1,6 20 N·cm 7,6 3,6 2,3 6,1 - 1,5 straight - Semi-sphere
1,6 20 N·cm 7,8 2 2,3 5,36 7,03 0,81 conical 15º 45º chamfer
1,6 20 N·cm 8,4 3,5 2,3 6,8 - 1,6 straight - Semi-sphere
N1-72 25 N·cm 7,1 2,6 2,3 5,56 5,65 1,45 conical 70º 45º chamfer
1,8 25 N·cm 4,4 2,75 2,3 3 - 1,4 straight - Semi-sphere
1,8 25 N·cm 4,8 2,8 2,3 3,22 3,65 1,15 conical 30º Semi-sphere
1,8 25 N·cm 6,5 3,3 2,4 5 - 1,5 straight - Semi-sphere
1,8 25 N·cm 7,5 3,3 2,3 6,1 - 1,4 straight - Semi-sphere
2 25 N·cm 4,7 3 2,3 3,3 - 1,4 straight - Semi-sphere
2 25 N·cm 5 2,8 2,3 3,39 3,6 1,4 conical 30º Semi-sphere
2 25 N·cm 5,1 3,1 2,3 3,6 - 1,5 straight - Semi-sphere
2 25 N·cm 6 2,7 2,3 4,5 - 1,5 straight - Semi-sphere
2 25 N·cm 6,5 2,7 2,3 5 - 1,5 straight - 45º chamfer
2 25 N·cm 6,7 2,3 2,59 3,65 5,68 1,02 conical 15º 45º chamfer
2 25 N·cm 7,4 3,3 2,3 6 - 1,4 straight - Semi-sphere
2 25 N·cm 7,5 2,75 2,3 5,93 6,18 1,32 conical 35º 45º chamfer
2 25 N·cm 8,2 4,7 2,4 6,7 - 1,5 straight - Semi-sphere
2 25 N·cm 9 4 2,3 7,5 - 1,5 straight - Semi-sphere
2,5 25 N·cm 5,4 3,8 2,85 4,1 - 1,3 straight - Semi-sphere
2,5 25 N·cm 6,7 4,6 2,85 5,1 - 1,6 straight - Semi-sphere
TPDH14L39
TPDH14
TPDHST
TPDH14L52
TPDH16
TPDH16L6
TPDH16L73
TPDH16L76
TPDH16L78
TPDH16L84
TPDH17L71
TPDH18
TPDH18L48
TPDH18L65
TPDH18L75
TPDH2
TPDH2L5
TPDH2L51
TPDH2L6
TPDH2L65
TPDH2L67
TPDH2L74
TPDH2L75
TPDH2L82
TPDH2L90
TPDH25
TPDH25L67
3.0 DYNAMIC ABUTMENT® SCREWS FOR CAD-CAM
*See pag. 2
-
29
REFE
REN
CE
MET
RIC
TORQ
UE
TOTA
L LE
NG
TH
THRE
AD L
ENG
TH
HEAD
DIA
MET
ER
A LE
NG
TH
B LE
NG
TH
C LE
NG
TH
SETT
LEM
ENT
ANG
LE
THRE
AD E
NTR
Y
CON
NEC
TIO
N
TCO
TST
TUC16
TAST16
T3I
TKL
TBTI
TECKALL125
TRPL35
TECKDU 125
TZIML76
TZIM
TSYN48
TOCT
TUC
TRPL
TAST2
TUC25
1,4 15 N·cm 4 2 2,3 2,2 - 1,8 straight - 45º chamfer 1,20 Hex.
1,4 15 N·cm 3,9 1,91 2,4 2,1 - 1,8 straight - 45º chamfer 1,20 Hex.
1,6 20 N·cm 7 2,79 2,3 4,86 5,44 1,56 conical 45º 45º chamfer 1,30 Squa.
1,6 20 N·cm 8,25 3,03 2,45 6,25 - 2 straight - 45º chamfer 1,27 Hex.
1,6 20 N·cm 9,3 3,3 2,3 7,3 - 2 straight - Semi-sphere 1,30 Squa.
1,8 25 N·cm 6 3,18 2,4 3,5 3,85 2,15 conical 45º 45º chamfer 1,50 Hex.
1,8 25 N·cm 7 3,2 2,5 5,2 - 1,8 straight - 45º chamfer 1,30 Squa.
1,8 25 N·cm 7,2 4,47 2,4 2,3 6,2 1 conical 30º 45º chamfer 1,25 Hex.
1,8 25 N·cm 10,2 3,15 2,45 8,4 - 1,8 straight - 45º chamfer 1,30 Squa.
1,8 25 N·cm 9,8 5,094 2,4 8,3 8,8 1 conical 30º 45º chamfer 1,25 Hex.
N1-72 25 N·cm 7,6 2,8 2,3 5,6 5,76 1,84 conical 70º 45º chamfer 1,25 Hex.
N1-72 25 N·cm 8,17 3 2,4 5,31 5,87 2,3 conical 45º 45º chamfer 1,30 Squa.
2 30 N·cm 5 3,06 2,49 3,26 3,5 1,5 conical 45º 45º chamfer 1,30 Squa.
2 30 N·cm 7,45 3 2,4 5,7 5,9 1,55 conical 45º 45º chamfer 1,30 Squa.
2 30 N·cm 7,4 3,34 2,4 5,1 5,6 1,8 conical 45º 45º chamfer 1,20 Hex.
2 30 N·cm 10,2 3,15 2,45 8,4 - 1,8 straight - 45º chamfer 1,30 Squa.
2 30 N·cm 10,3 4 2,45 8,3 - 2 straight - 45º chamfer 1,27 Hex.
2,5 30 N·cm 7,41 3,5 2,87 4,75 5,29 2,12 conical 45º Semi-sphere 1,30 Squa.
DESCRIPTION OF STRAIGHT ABUTMENT SCREWS
*See pag. 2
Thread Length
Settlement
Connection
Thread Entry
Length A
Total Length
Length C
Head
Ø
Thread LengthAngle
Connection
Thread Entry
Length ALength BLength C
Total Length
Head
Ø
-
30
TAllADIUM GUARANTEE
TERMS AND CONDITIONSThese guarantee terms and conditions (“T&C”) cover the entire range of Talladium España SL products (“Products”), that are manufactured by Talladium España SL and distributed by Geoda Medical, SL or its official dealers.The guarantee described in these T&C’s is exclusively for the benefit of the clinician (“Clinician”) and of the dental technician (“Technician”) and not for the benefit of any third parties, institutions or patients.
GUARANTEE PERIODTalladium España SL offers a lifetime guarantee for its entire range of products.
GUARANTEE SCOPESubject to the limitations and exceptions described in these T&C’s, Talladium España SL will offer the following benefits:QUALITY- If there are defects in the materials or in the manufacturing of the product, Talladium España SL will replace the product at no additional cost.SAFETY- If all instructions for use have been observed and the prosthesis needs to be remade due to the fault of the Dynamic Abutment® System, Talladium España SL will replace the abutments and screws that are necessary to remake the prosthesis at no cost. Talladium España SL will reimburse the costs of manufacture for such prosthesis.
CLAIM REQUIREMENTS AND PROCEDURETo receive the benefits indicated in these T&C’s, the treating Clinician must satisfy the following requirements:1) The clinician or technician must contact the customer service department to make the claim2) A completed claim form must be sent with the faulty product to Talladium España SL’s office.3) Clinicians and Technicians presenting a claim in agreement with these T&C’s must be up to date on any payments that are due.4) All procedures must be used in accordance with Talladium España SL’s instructions, as well as in accordance with common dentistry practices.The return shipping costs will be assumed by Talladium España SL in all of the cases covered by these T&C’s.
GENERAL LIMITATIONS OF THIS GUARANTEEWith the exception of the guarantee described in these T&C, neither Talladium España SL nor its representatives, nor third parties manufacturing or distributing the Products, represent or offer a guarantee, agreement or any other express or implicit, oral or written, commitment, with respect to the Products (without limitation), including guarantees involved in the marketing, durability or suitability for individual uses or purposes.In addition and within the maximum extent permitted by the relative law, Talladium España SL rejects (on its own behalf, and on behalf of its representatives and third parties that manufacture or distribute Products) any responsibility with respect to any direct or indirect damage caused, which may result from or be a consequence of the design, composition of the dental prosthesis into which the Products are integrated.
GUARANTEE EXCLUSIONS- Talladium España SL limits this guarantee to:- Transformed abutments that form part of the dental prosthesis. But not the screws used to anchor them.- Problems derived from the use of laboratory screws for the definite fixation of the prosthesis. Talladium España SL has sterile clinical screws that satisfy that function.- Clinical screws that have been in the mouth for more than 2 years, as it is understood that the patient has to have annual check-ups with the subsequent change of screws.- The fault is due to normal wear and tear.
AMENDMENT OR SUSPENSION OF THE GUARANTEETalladium España SL reserves the right to amend or withdraw these T&C at any time and without prior notification. Any modification or suspension shall not affect products already installed in patients.
-
31
Each and every commercial trademark mentioned on this catalogue are fully registered by their respective companies, the appearing images are just to provide an orientations.Talladium reserves the rigth to modify this document without previous notice.Talladium is not responsible for the adequate execution of this products if the warning indications corresponding to every reference are not contemplated.
AV. MADRID 17, ALTILLO 1ª25002 LLEIDA (SPAIN)
TEL. +34 973 289 [email protected]
-
www.dynamicabutment.com
ENG
- e
ditio
n 20
14/1