IManager U2000 Web LCT V100R006C02SPC301
This document describes how to run the U2000 web LCT properly
2013
Mohammed Hussein Jasim
Omnnea wireless telecom
7/18/2013
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
IManager U2000 Web LCT V100R006C02SPC301Access steps
Caution:No part of this document may be reproduced or transmitted in any form or by any
means without prior written consent of Nakheel (Omnnea) Company.
Address:Iraqbabil
www.omnnea.com:Website
[email protected]:Email
AUTHOR Mohammed Hussein Jasim
DOCUMENT OWNER ELNAKHEEL
SECTION TRANSMISSION
DEPARTMENT TECHNICAL
REVIEW PERIOD 2 Days
CUSTOMER NAME ELNAKHEEL, IRAQ
Purpose:This document describes how we can run U2000 web LCT properly.
Related Versions:The following table lists the product versions related to this document.
VersionProduct NameV100R006C02SPC301IManager U2000 Web LCT
OrganizationThis document is organized as follows.
Items1-Getting Started
2- Starting the Web LCT
3- Web LCT main window
http://www.omnnea.com/mailto:[email protected]:[email protected]://www.omnnea.com/ -
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
1-Getting Started
The following topics describe the operations that ensure a smooth.
1-1-Configuration Requirements
The hardware and software configuration requirements for the Web LCT system are
described. The Web LCT system can be installed on Windows.
1-1-A: Hardware requirements:
CPU: dual core or higher
RAM: 1 MB (recommended1MB or higher for Win.7) 512 MB for Win XP
Ethernet interface: 10/100 Mbit/s
1-1-B: Software requirements:
The Web LCT supports the following operating systems:
1-1-C:the device types, version and Software version that can be managed by the
Web LCT as following.
Product Type ProductName
Compatible NE SoftwareVersion
OSN OptiX OSN9560
5.51.05.20
(V100R002C00)
5.51.06.10
(V100R005C00)
5.51.07.10
(V100R006C00)
5.51.07.30-5.51.07.59
(V100R006C01)
OS Version Database Version Remarks
Windows 7 Professional
64-bit
N/A Windows Internet Explorer
of versions 6.0 SP2, 7.0, 8.0
and 9.0 is supported.
Windows 7 Professional
32-bit
N/A Windows Internet Explorer
of versions 6.0 SP2, 7.0, 8.0and 9.0 is supported.
Windows XP Professional
SP2/SP3
N/A Windows Internet Explorer
of versions 6.0 SP2, 7.0, 8.0
and 9.0 is supported.
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
5.51.08.10
(V100R007C00)
Product Type ProductName
Compatible NE SoftwareVersion
OTN OptiX OSN
1800
5.67.01.10
5.67.01.20
5.67.02.10
(V100R002C00)
5.67.03.10
(V100R003C00)
5.67.03.20
(V100R003C01)5.67.03.30
(V100R003C02)
OptiX OSN
3800
5.52.01.10
5.52.02.10
5.52.03.20
5.52.04.10
5.52.04.20
(V100R004C02)
5.52.04.30(V100R004C03)
5.52.05.20
(V100R004C04)
5.51.06.10
(V100R005C00)
5.51.07.10
(V100R006C00)
5.51.07.30
(V100R006C01)5.51.07.60
(V100R006C03)
5.51.08.10
(V100R007C00)
OptiX OSN6800
5.51.01.10
5.51.02.10
5.51.03.20
5.51.04.10
5.51.04.20(V100R004C02)
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
5.52.04.30
(V100R004C03)
5.51.05.20
(V100R004C04)
5.51.06.10(V100R005C00)
5.51.07.10
(V100R006C00)
5.51.07.30
(V100R006C01)
5.51.07.60
(V100R006C03)
5.51.08.10
(V100R007C00)OptiX OSN8800 T16
5.51.07.10
(V100R006C00)
5.51.07.30
(V100R006C01)
5.51.07.60
(V100R006C03)
5.51.08.10
(V100R007C00)
OptiX OSN8800 T32 5.51.04.20(V100R001C01)
5.51.04.30
(V100R001C02)
5.51.05.20
(V100R002C00)
5.51.05.21
(V100R002C02)
5.51.06.10
(V100R005C00)
5.51.07.10
(V100R006C00)
5.51.07.30
(V100R006C01)
5.51.07.60
(V100R006C03)
5.51.08.10
(V100R007C00)
OptiX OSN8800 T64
5.51.05.21
(V100R002C02)
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
5.51.06.10
(V100R005C00)
5.51.07.10
(V100R006C00)
5.51.07.30(V100R006C01)
5.51.07.60
(V100R006C03)
5.51.08.10
(V100R007C00)
OptiX OSN1832
5.51.08.10
(V100R007C00)
OptiX OSN8800
5.51.08.10
(V100R007C00)OptiX OSN9800 P18
5.51.08.10
(V100R001C00)
Product Type ProductName
Compatible NE SoftwareVersion
RTN OptiX RTN610
5.54.01.10
5.54.01.20
5.54.02.105.54.03.10
(V100R003)
OptiX RTN620
5.54.01.10
5.54.01.20
5.54.02.10
5.54.03.10
(V100R003)
5.54.05.10
(V100R005)5.54.05.20
(V100R005C01)
OptiX RTN605
5.60.01.10
(V100R001)
5.60.03.10
(V100R002)
5.60.05.10
(V100R005)
OptiX RTN905 5.95.05.10(V100R005C00)
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
OptiX RTN
910
5.76.01.10
(V100R001C00)
5.76.01.20
(V100R001C01)
5.76.01.30(V100R001C02)
5.76.02.10
(V100R002C00)
5.76.02.20
(V100R002C01)
5.76.03.10
(V100R003C00)
5.76.03.20
(V100R003C01)5.76.03.30
(V100R003C02)
5.76.03.40
(V100R003C03)
5.76.05.10
(V100R005C00)
OptiX RTN950
5.76.01.10
(V100R001C00)
5.76.01.20(V100R001C01)
5.76.01.30
(V100R001C02)
5.76.02.10
(V100R002C00)
5.76.02.20
(V100R002C01)
5.76.03.10
(V100R003C00)
5.76.03.20
(V100R003C01)
5.76.03.30
(V100R003C02)
5.76.03.40
(V100R003C03)
5.76.05.10
(V100R005C00)
OptiX RTN980
5.83.03.10
(V100R003C00)
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
5.83.03.30
(V100R003C02)
5.83.03.40
(V100R003C03)
5.83.05.10(V100R005C00)
OptiX RTN
310
5.92.01.10
(V100R001C00)
1-1-D: Browser requirement:
Versions: Internet Explorer 6.0 or 7.0.The security level: Medium or Low so make sure to close Window firewall
and Antivirus.
LCTStarting the Web-2
2-1Procedure
1.
Start the Web LCT computer.2. Double-click the shortcut icon Start Web LCTon the desktop.
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
The Web LCT is properly started and the login page for the Web LCT is
displayed.
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
Certificate error .click continue to the web site
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
Kasper Key: make sure you turned off your antivirus
3. Enter the Password.
NOTE:
By default, the user name is admin, and the initial password is
Changeme_123.
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
Web LCT main window:-3
The web LCT main user interfaces and the operations that you can perform on
these user interfaces are described
3-1 NE list:
NE List is the main user interface of the Web LCT. The Web LCT manages NEs in
the NE List. In this user interface, you can create or delete NEs. You can also log in to
an NE, log out of an NE, backup the NE database, view the system log, and set the
time format.
Note:
1- You need to Login GE NE first before login any NE, otherwise you cannot access.
2- If the NE does not connect to any Get Way then the U2000 Web LCT will suppose
that the NE is a Get Way.
3- Try to change domain field by interring the prober IPs range based on your
network planning .Our IPS range (129.9.255.255) as shown below
FromNE searchchoose Advanced searchthen Addto inter your IP domain.
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
Figure above shows the Europe NE List window of the Web LCT .
-
5/24/2018 IManager U2000 Web LCT V100R006C02SPC301setup Procedures
U2000 WEB LCT
3-2 NE ExplorerNE Explorer is the main operation user interface of the Web LCT. It regards one NE
as an object. In this user interface, you can configure, manage and maintain the NEs
in different levels such as on a per-NE basis, on a per-board basis or on a per-port
basis. It is the primary user interface for NE commissioning and configuration on the
Web LCT. The NE Explorer provides the Function Tree for operation navigation. Youcan select an object on which you want to perform the operation, choose the
corresponding function item from the Function Tree, and then the configuration user
interface of the function is displayed.
The RTN NE Explorer is shown in Figure above