    Images of

    ElectroStaticDischarge Damage

    www.desco.com

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    2/14

    Damage visible usingScanning Electron Micrograph (SEM)

    after significant enhancementby delayering and etch enhancement.

    Used with permission ofHi-Rel Laboratories, Inc.

    Spokane WA 99217www.hrlabs.com

    Images of ESD damage

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    3/14

    Photo of ESD arcing from finger to componentThis is not a computer simulation.

    Technician was connected to a small magneto

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    4/14

    This is not HBM-ESD. Extensive damage on thistransistor where the bond has melted is typical ofsurges from Inductors, Transformers, and Motors.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    5/14

    Arcing of this nature within an integrated circuit is typical oftesting damage. Human Body Model ESD does not create

    sufficient damage to be seen in an optical microscope.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    6/14

    Optical photo of a large Integrated Circuit which hasexperienced ESD damage to the pin noted by the arrow .

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    7/14

    Higher magnification photo of pin noted by the arrow in the priorslide This taken at 400 times magnification on a 4" X 5" photo.

    The damage is noted as the "fuzz" at the end of the arrow.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    8/14

    Now you see it!! Overlying glassivation has been removedand the surface decorated to show the ESD damage at 5,000

    times magnification in this scanning electron micrograph.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    9/14

    Techniques used to locate HBM-ESD damage in an integrated circuit.Clockwise from the upper left optical photo at 400X shows no damage.

    The upper right hand scanning electron micrograph (SEM) shows nodamage. The lower right hand image is the current flow in the device

    which shows asubsurface arcbetween the twometal lines. Thelower left photo is

    a combination ofthe SEM imageand the currentflow image.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    10/14

    Scanning electron micrograph (SEM) image of the devicein prior slide after glassivation removal and surfacedecoration. The enlargement 2,000 times magnification.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    11/14

    Optical micrograph of an Integrated Circuit damaged by HBM ESD.Damage has occurred in the large thin oxide metal capacitor in theupper center of the image. However, no physical damage is visible.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    12/14

    Scanning electron micrograph (SEM) image of the ESD damage afterremoval of the capacitor metallization. Note the characteristic

    eruption thru the oxide. Magnification is 10,500 times.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    13/14

    Optical image of an Integrated Circuit damaged by HBM ESD. Thesecond pin from the bottom left is good and its mirror image, secondfrom the right is damaged. However, no physical damage is visible.

    www.desco.com

  • 8/13/2019 Images of Es d Damage

    14/14

    Scanning electron micrograph (SEM image of the damage site on theIntegrated Circuit shown in prior slide. Metal has been removed expose

    the underlying damage site. Magnification is 6,450 times.