If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red=...

15
Danger of electrical shock, burns or death. Always remove all power sources before aempng any repair, service or diagnosc work. Power can be present from shore power, generator, inverter or baery. All power sources must be disabled and secured before performing any service. If you lack the skills, tools or equipment to perform diagnosc or repair work leave such work to an authorized Winnebago Industries dealer or other qualified shop. Copyright © 2015 Winnebago Industries, Inc.

Transcript of If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red=...

Page 1: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

Danger of electrical shock, burns or death. Always remove all power sources before attempting any repair, service or diagnostic work. Power can be present from shore power, generator, inverter or battery. All power sources must

be disabled and secured before performing any service.

If you lack the skills, tools or equipment to perform diagnostic or repair work leave such work to an authorized

Winnebago Industries dealer or other qualified shop.

Copyright © 2015 Winnebago Industries, Inc.

Page 2: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

6

A

1

CHKR

DO NOT SCALE DRAWING

4

ONE-PLACE (X.X)

SHEET

7

REV

DWGNO

DFTR

1

MATERIAL:

DSNR

REV

TWO-PLACE (X.XX)

5

ZONE

A

ANGLE

6 5

8

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

WHOLE DIM (X)

4

REVISION RECORD

FIRST USEDM.E.

C

B

TITLE:

OF

C

DATE

3

DFTR-ORIG

2

THIRD ANGLE

D

REV

D

P.E.

ORIG. DATE

B

DATE

UNSPECIFIED TOLERANCES ARE:

COPYRIGHT 2014WINNEBAGO

INDUSTRIES, INC.

2 REF:

ALL DIMENSIONS ARE IN MILLIMETERS

8

PROJECTION

7

3

PART NO

A

300 & F SER

1.50.501

1 14

1

134940

PANEL-MONITOR 2-TANK

RELEASE

3. LETTERS ON MAIN HEADING TO BE 5MM HIGH.

1. SUGGESTED VENDOR: VENTLINE.

0.89

DWG NO

W/O GEN

134940-01

2. BLACK PANEL WITH WHTIE GRAPHICS.

NOTES:FOR COLOR VARIATIONS OF THIS PART

134940-02

SEE CHART

W/GEN

4. CUTOUT 130 X 192.

5. SWITCH RATING SHALL BE EMBOSSED ON THE SIDE OF THE 12V SWTICHES.

134940-03

134940-04 W/G SOLAR

SWITCH,METER,HARNESS

W/GEN SWIT134940-05

SHEET

1

---

3

4

2

HOUSING-AMPUNIVERSAL METER-N-LOK1-480710-0CONTACT-PIN350538-1

1

4

3

2

PIN #

HOUSING-AMPUNIVERSAL MATE-N-LOK1-480702-0CONTACT-PIN350538

65

1 2 3

4

1413

121110

987

15

38

(4)5.0

(4)5.0 (4)5.0

158.75

209.55

1. 16 RED GENERATOR METER (+)2. 16 YEL GENERATOR START3. 16 BRN GENERATOR STOP4. 16 BLK GENERATOR (-)

GREENLIGHT

REDLIGHT

1. 14 BLK (HOUSE +12VDC)2. BLANK3. 14 WHT (GROUND)4. 20 RED (WATER TANK)5. 20 BRN (BLACK TANK)6. 20 GRY (GRAY TANK)7. 12 RED/WHT (REMOTE WATER PUMP SWITCH)8. 12 RED (WATER PUMP SWITCH)9. 12 WHT/RED (REMOTE WATER PUMP)10. BLANK11. BLANK12. 20 WHT/GRN (LP TANK SENSOR)13. 16 YEL (WATER HEATER IGNITION)14. BLANK15. 20 WHT/BLU (WATER HEATER INDICATIOR)

SPRINGROCKERSWITCH

GREENLIGHTEDROCKERSWITCH

ROCKERSWITCH

SPRING ROCKERSWITCH

134940-06

W/G SOL/SE

W/G SW/SEN

9,10

7,8

11,12

W/O GEN/SE

134940-09

W/GEN/SEN 5,6

134940-07

134940-08

WEIGHT(LBS.)

0.89

0.89

0.89

0.89

0.89

0.89

0.89

0.89

134940

DWG NO

134940-10 W/O GEN/SEN

SHEET

13,14

WEIGHT(LBS.)

0.67

START

HOBBSGENERATOR

STOP

HOLD START UNTILGERERATOR STARTS

DISPLAY ON WHENGENERATOR RUNS

HOURS

ON

OFF

WATERHEATER

LEVELSTEST

WATER PUMP

PILOT OUT PUMP ON

BLACKWATER

GREYWATER

FRESHWATER

L.P.GAS

BATTCHG

F F F F

E E E E

2/3 2/3 2/3 2/3

1/3 1/3 1/3 1/3

09-Mar-2015

Page 3: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

321

5 6

134940

HOUSING-AMPUNIVERSAL METER-N-LOK1-480710-0CONTACT-PIN350538-1

15

7 8 9

10 11 12

13 14

PANEL-MONITOR 2-TANK

4

2

300 & F SER

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

38.0(4)5.0

(4)5.0

(4)5.0

158.75

209.551. 14 BLK (HOUSE +12VDC)2. BLANK3. 14 WHT (GROUND)4. 20 RED (WATER TANK)5. 20 BRN (BLACK TANK)6. 20 GRN (GRAY TANK)7. 12 RED/WHT (REMOTE WATER PUMP SWITCH)8. 12 RED (WATER PUMP SWITCH)9. 12 WHT/RED (REMOTE WATER PUMP)10. BLANK11. BLANK12.20 WHT/GRN (LP TANK SENSOR)13 16 YEL (WATER HEATER IGNITION)14. BLANK15. 20 WHT/BLU (WATER HEATER INDICATOR)

SPRINGROCKERSWITCH

GREEN LIGHTEDROCKERSWITCH

REDLIGHT

ROCKERSWITCH

GREEN LIGHT

134940

START

GENERATOR

STOP

HOLD START UNTILGERERATOR STARTS

DISPLAY ON WHENGENERATOR RUNS

ON

OFF

WATERHEATER

LEVELSTEST

WATER PUMP

PILOT OUT PUMP ON

BLACKWATER

GREYWATER

FRESHWATER

L.P.GAS

BATTCHG

F F F F

E E E E

2/3 2/3 2/3 2/3

1/3 1/3 1/3 1/3

PLUGED

PLUGED

09-Mar-2015

Page 4: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

321

5 6

134940

HOUSING-AMPUNIVERSAL METER-N-LOK1-480710-0CONTACT-PIN350538-1

15

7 8 9

10 11 12

13 14

1

4

1-16 GRN2-16 RED2

PIN #

SPRINGROCKERSWITCH

PANEL-MONITOR 2-TANK

PIN #

GREENLIGHT

3

300 & F SER

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

4

2

1

1-16 RED GENERATOR METER (+)2-16 YEL GENERATOR START3-16 BRN GENERATOR STOP4-16 BLK GENERATOR )-)

3

PIN #

HOUSING-AMPUNIVERSAL MATE-N-LOK1-480702-0CONTACT-PIN380538-1

11-16 BLK2-16 RED 2

38.0

(4)5.0

(4)5.0

158.75

209.55

1. 14 BLK (HOUSE +12VDC)2. BLANK3. 14 WHT (GROUND)4. 20 RED (WATER TANK)5. 20 BRN (BLACK TANK)6. 20 GRY (GRAY TANK)7. 12 RED/WHT (REMOTE WATER PUMP SWITCH)8. 12 RED (WATER PUMP SWITCH)9. 12 WHT/RED (REMOTE WATER PUMP)10. BLANK11. BLANK12. 20 WHT/GRN (LP TANK SENSOR)13. 16 YEL (WATER HEATER IGNITION)14. BLANK15. 20 WHT/BLU (WATER HEATER INDICATOR)

GREENLIGHTEDROCKERSWITCH

REDLIGHT

SPRINGROCKERSWITCH

ROCKERSWITCH

HOUSING-AMP(UNIVERSAL-MATE-N-LOK)1-480698-0PIN350538-0

HOUSING-AMP(UNIVERSAL-MATE-N-LOK)1-480699-0SOCKET350537-1

(4)5.0

134940

START

STOP

ON

OFF

WATERHEATER

LEVELSTEST

WATER PUMP

PILOT OUT PUMP ON

BLACKWATER

GREYWATER

FRESHWATER

L.P.GAS

BATTCHG

F F F F

E E E E

2/3 2/3 2/3 2/3

1/3 1/3 1/3 1/3

HOLD STAT UNTILGENERATOR STARTS

DISPLAY ON WHENGENERATOR RUNS

SOLARCHARGING

WHENLIT

HOBBS

09-Mar-2015

Page 5: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

321

5 6

HOUSING-AMPUNIVERSAL METER-N-LOK1-480710-0CONTACT-PIN350538-1

15

7 8 9

10 11 12

13 14

1

4

2

PIN #

HOUSING-AMPUNIVERSAL MATE-N-LOK1-480702-0CONTACT-PIN350538

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

300 & F SER

4

4

134940

PANEL-MONITOR 2-TANK

3

38.0(4)5.0

(4)5.0

(4)5.0

158.75

209.55

1.2. 16 YEL GENERATOR START3. 16 BRN GENERATOR STOP4. 16 BLK GENERATOR (-)

1. 14 BLK (HOUSE +12VDC)2. BLANK3. 14 WHT (GROUND)4. 20 RED (WATER TANK)5. 20 BRN (BLACK TANK)6. 20 GRY (GRAY TANK)7. 12 RED/WHT (REMOTE WATER PUMP SWITCH)8. 12 RED (WATER PUMP SWITCH)9. 12 WHT/RED (REMOTE WATER PUMP)10. BLANK11. BLANK12. 20 WHT/GRN (LP TANK SENSOR)13. 16 YEL (WATER HEATER IGNITIION)14. BLANK15. 20 WHT/BLU (WATER HEATER INDICATOR)

SPRINGROCKER SWITCH

ROCKER SWITCH

GREENLIGHT

SPRINGROCKERSWITCH

GREENLIGHTEDROCKERSWITCH

REDLIGHT

134940

START

GENERATOR

STOP

HOLD START UNTILGERERATOR STARTS

ON

OFF

WATERHEATER

LEVELSTEST

WATER PUMP

PILOT OUT PUMP ON

BLACKWATER

GREYWATER

FRESHWATER

L.P.GAS

BATTCHG

F F F F

E E E E

2/3 2/3 2/3 2/3

1/3 1/3 1/3 1/3

09-Mar-2015

Page 6: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

05 D SEIRES

5

134940

PANEL-MONITOR

PHILIPS IND. INC.

FUNCTION DRAWING,

F

2/3

N.C.

N.C.

WATER HEATER

4-6-04

12/3/03

GENERATOR HARNESS= L7751-00INTERNAL & SWITCH HARNESS= L7752-00

TEST HARNESS= L7753-00TEST BOX= L8506-00

SEE SHEET 2 ECN 16381

2. REF. DWG'S:

PCB= L5131-02

NOTES:

4. BEFORE PACKING, SECURE HARNESS WITH VD0169-00 TIE WRAP ON RIGHT SIDE POST.

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

A

ENGINE BATT.

+

A

PUMP ON

1/3

E

1/31/3

EE

ENGLISH (TOLERANCE UNLESS SPECIFIED)

MPR

RJLRJL

RJL

N.C.

RJL

1/3

SEE BOM PAGE 2

WINNEBAGO

GENERATOR STARTS

HEATERWATER

HOLD START UNTIL

8.25(REF.) OFF

ECN 16261

ON

START

PA

GE

1 O

F 2

LA10

71-0

0

PUMPTEST

12/3/03MPR

GENERATOR RUNS

WATER

DISPLAY ON WHEN

SCALE:

DWG. NO.

MATERIAL

NAME

BLANKSIZE

CHG.

PART NO.

BY

USEDON

CHASSIS GROUND

2/3

MPR

MATERIALREQ'D

WHT/BLU= WTR. HTR. PILOT LT.YLW= D.S.I. WTR. HTR. POS.

-

VENTLINE WIRING

BRN= BLACK WATER TANK SENSOR

14

PAGE 1 OF 2

12/3/03

F

RELEASED TO PURCHASING & PRODUCTION.

MONITOR PANEL

11

GAS

REMOTE SWITCH

REL

1

FEMALEMALE

WATER

4-21-04

2/3

F

9

8

13

3

15

1

5

6

12

PILOT OUT

F

1/3

E

2/3

WATERBLACK

4

GREY

MPR VENTLINE DIVISIONBRISTOL, INDIANA 46507

DESCRIPTION DWG SIZE

CHECKED DATE

DRAWN DATE

APPV'D DATE

LP GAS TANK

BLACK TANK GREY TANK

TANK SENSOR ARRAYS SUPPLIED

LTR. DESCRIPTION

CHG

2/3

FULL

1/3

LEVELS

HOURS 1/10STOP

6.25(REF.)

BLK= GENERATOR NEGATIVE

YLW= GENERATOR STARTBRN= GENERATOR STOP

RED= GENERATOR POSITIVE

15 CKT CONNECTOR

FULL

1/32/3

1 2

34

21

4 CKT CONNECTORMALE FEMALE

GENERATOR

2/3

All Rights Reserved, including the right to reproduce this document or any part thereof

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

GRY= GREY WATER TANK SENSOR

14-RED/WHT= WATER PUMP REMOTE SW.

RED= FRESH WATER TANK SENSOR

14-WHT/RED= WATER PUMP REMOTE SW.

L.P. BATTFRESHWATER

GENERATOR

WATER TANK

7

SEE SHEET 2 ECN 16394

N.C.

2

LA1071-00

C

SERVED THE PURPOSE FOR WHICH DELIVERED.

1 PL. .020

2

DATE

BY THIRD PARTY VENDOR

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

3 PL. .005

CONFIDENTIAL

CUSTOMER WIRING

WHT/GRN= LP GAS TANK

WHT= NEGATIVE BATT. TERMINAL

THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

BLK= HOUSE BATTERY POS.

14-RED= WATER PUMP

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVINGTO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

WATER PUMP

0 PL. .0402 PL. .010

FRACTIONS 1/64

FULL

NONE

WATER PUMP

BY

21

CHK.

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

10

134940 09-Mar-2015

Page 7: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

05 D SEIRES

6

134940

PANEL-MONITOR

1L0115-00SWITCH, SPDT (ON)-OFF-(ON), BLK1L0112-00

L0775-00

SWITCH, SPST MOM. (ON)-OFF, BLK1L0111-00

PCB SPACER2L0844-00

SWITCH, SPST ON-OFF, BLK, GRN LT.1L0109-00

YLW

4. BEFORE PACKING, SECURE HARNESS WITH

A

PRODUCT LABELPRINTING DETAIL

NO SCALE

PA

GE

2 O

F 2

LA10

71-0

0

SENSORSNON-CONTACT

(MFG DATE)

FOR USE WITHLA1071-00

GEN.

DETAIL -C

2LOAD

1L0522-00

GNDWHT

DETAIL -B

WHT

BLK

YLWGND

1b

+12 V

3

HEATERWATER

3 HEX NUT, 6-32

L0531-00 2 FIBER WASHER

L0451-00 1 LABEL - SEE PRINTING DETAIL ABOVE

L5131-02 1 PCB

L7751-00 1 HARNESS, GENERATORL7752-00 1 HARNESS, INTERNAL & SWITCH

WHT

WHT A

BLK

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

TEST HARNESS= L7753-00

INTERNAL & SWITCH HARNESS= L7752-00GENERATOR HARNESS= L7751-00

TEST BOX= L8506-00

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.2. REF. DWG'S:

PCB= L5131-02

NOTES:

6

5

12

15

4

13

3

1

L7752-00 VENTLINE WIRING CUSTOMER WIRING

SILKSCREENED CHASSIS

7

8

9

4

1

TESTLEVELS

WHT

BLK+12 V

LOAD

1a

2

3

_+

1

WHT

WHT

HEATERWATER

L0844-002 EA.

WHT

TESTLEVELS

L0531-002 EA.

L0115-00

L0109-00

SWITCH, SPDT ON-ON, BLK

L0111-00

1/10HOURS

CC0558-00 1

L5131-02 WAS L5118-02 ECN 16394

ADDED LABEL DETAIL ECN 16381

L7751-00

A

B 4-21-04

4-6-04

ECN 16261

RJL RJL

RJLRJL

MPR

START

2/32/3

E

1/3

E

1/3

2/3

E

1/3

E

2/3

1/3

FF F F

DETAIL -A

FOR L0109-00 "MARQUARDT"

LA1071-00

SHOWN APPROX. 2X SCALE

L0522-002 EA.

L0522-00 1 EA

CHGWATER GASWATERWATER

L5131-02

HOBBS HOUR METER

L0112-00

SEE DETAIL -A

FRESH L.P.

CC0558-00

LEVELSTEST

SEE NOTE 4.

L0393-05(REF.)

TESTLEVELS WATER

BLK

ON

WATER

PCB

PUMP

L0775-00

TIE WRAP

SEE DETAIL -B OR -C

8.25(REF.)

RED

GENERATOR STARTS

WATER

DISPLAY ON WHEN

FOR USE WITH

HEATER

PUMP ON 1

1

1a

L5131-02

WHT

BLKWHT

1b

GENERATOR RUNS

L0451-00

PILOT OUT

OFF

GREYBLACK BATT

CC0558-00

SHOWN APPROX. 2X SCALE

HEATER

SEE NOTE 4.

VD0169-00 1 EA FOR L0109-00 "CARLINGSWITCH"SHOWN APPROX. 2X SCALE

CKT 5 BRN= BLACK WATER TANK SENSORCKT 6 GRY= GREY WATER TANK SENSOR

CKT 13 YLW= D.S.I. WTR. HTR. POS.

CKT 15 WHT/BLU= WTR. HTR. PILOT LT.

CKT 8 14-RED= WATER PUMP

CKT 1 BLK= HOUSE BATTERY POS.

CKT 12 WHT/GRN= LP GAS TANK

CKT 7 14-RED/WHT= WATER PUMP REMOTE SW.

CKT 4 RED= FRESH WATER TANK SENSOR

CKT 3 WHT= NEGATIVE BATT. TERMINAL

CKT 9 14-WHT/RED= WATER PUMP REMOTE SW.

CKT 4 BLK= GENERATOR NEGATIVE

CKT 2 YLW= GENERATOR START

CKT 3 BRN= GENERATOR STOP

CKT 1 RED= GENERATOR POSITIVE

MPR

WATER

12/3/03RELEASED TO PURCHASING & PRODUCTION.REL

NONE

SEE BOM PAGE 2

WINNEBAGO

11/20/03MPR

11/20/03MPR

MONITOR PANELFUNCTION DRAWING,

LA1071-00

C

SERVED THE PURPOSE FOR WHICH DELIVERED.

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

CONFIDENTIALTHIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVEAND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

TO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

1

6.25(REF.)

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVING

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

All Rights Reserved, including the right to reproduce this document or any part thereof

PAGE 2 OF 20 PL. .0402 PL. .010

FRACTIONS 1/643 PL. .0051 PL. .020

ENGLISH (TOLERANCE UNLESS SPECIFIED)

BYCHK.

BYCHG.DATEDESCRIPTIONLTR.

APPV'D DATE

DRAWN DATE

CHECKED DATE

DWG SIZEDESCRIPTION

BRISTOL, INDIANA 46507VENTLINE DIVISIONPHILIPS IND. INC.

PART NO. REQ'D MATERIAL

ONUSED

SIZEBLANK

NAME

MATERIAL

DWG. NO.

SCALE:

HOLD START UNTIL

GENERATOR

STOP

PUMP

E

VD0169-00

SENSORSNON-CONTACT

VD0169-00 TIE WRAP ON RIGHT SIDE POST.

R

134940 09-Mar-2015

Page 8: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

05 D SERIES

7

134940

PANEL-MONITOR

GENERATOR

2

B

1/3

F

4-6-04

LP GAS TANK

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

1 PL. .020

SEE SHEET 2 ECN 16381

PAGE 1 OF 2

STOP

2

1/3

WATER TANK

2

WATER PUMP

MPR

2/3FULL

GREY TANK

1

TANK SENSOR ARRAYS SUPPLIED

RJL

A

FULL2/3

11

1/3

1

FEMALE

4-21-04

15 CKT CONNECTOR

L5131-02 WAS L5118-02 ECN 16394

1/3

8

REMOTE SWITCH

MALE

5

BY THIRD PARTY VENDOR

6.25(REF.)

RJL

6

1

RJL

ECN 16261

RJL

DRAWN DATE

14-RED= WATER PUMP

TEST

WATER

12/3/03

2/3

DWG SIZE

CHECKED DATE

WATER

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

NOTES:

USED

SCALE:

PA

GE

1 O

F 2

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVING

GAS

BY

FULL

1/3

14-RED/WHT= WATER PUMP REMOTE SW.

CONFIDENTIAL

FUNCTION DRAWING,

BLANK

WATER

GENERATOR STARTS

0 PL. .040

2/3

YLW= D.S.I. WTR. HTR. POS.

RED= FRESH WATER TANK SENSOR

1

CHG.

+

BRISTOL, INDIANA 46507

ENGLISH (TOLERANCE UNLESS SPECIFIED)

DESCRIPTION

14-WHT/RED= WATER PUMP REMOTE SW.

HARNESS, TEST= L7753-00

FRESHE

WHT= NEGATIVE BATT. TERMINAL

START

FRACTIONS 1/64

2/315

PCB= L5131-02

PHILIPS IND. INC.

E

MONITOR PANEL

CHASSIS GROUND

2/3

F

THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

MPR

1/3

8.25(REF.)

N.C.14

HARNESS, INTERNAL & SWITCH= L7752-00

2

11/21/03

REL

WHT/BLU= WTR. HTR. PILOT LT.

RELEASED TO PURCHASING & PRODUCTION

TEST BOX= L8506-00

N.C.

NAME

REQ'D

2 PL. .010

BATT

2. REF. DWG.'S:

CHG

SEE BOM PAGE 2

LA10

73-0

0

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

9

APPV'D DATE

TO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

ENGINE BATT.

4. BEFORE PACKING, SECURE HARNESS WITH

MATERIAL

WATER

GENERATOR RUNS

MPR

VD0169-00 TIE WRAP ON RIGHT SIDE POST.

VENTLINE WIRING

LTR.

NONE

WATER PUMP

PUMP ON

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

MATERIAL

CHK.

WATER HEATERGREY

VENTLINE DIVISION

LA1073-00

SIZE

DESCRIPTION

BRN= BLACK WATER TANK SENSOR

7

F

ON

WINNEBAGO

LEVELS

F

BLK= HOUSE BATTERY POS.

C

2/3

HEATER

10E

-

DISPLAY ON WHEN

BLACK TANK

PART NO.

PILOT OUT

MPR

BYDATE

OFF

E

All Rights Reserved, including the right to reproduce this document or any part thereof

ON

1/3

12

N.C.

BLACK

HOLD START UNTIL

WATER

CUSTOMER WIRING

WHT/GRN= LP GAS TANK

3

11/21/03

4

3 PL. .005

N.C.

L.P.

PUMP GRY= GREY WATER TANK SENSOR

13

SERVED THE PURPOSE FOR WHICH DELIVERED.

DWG. NO.

134940 09-Mar-2015

Page 9: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

05 D SERIES

8

134940

PANEL-MONITOR

DESCRIPTION

3

SENSORS

8.25(REF.)

REQ'D

BRISTOL, INDIANA 46507

APPV'D DATE

SCALE:

L0844-00

L0109-00

TEST

L7752-00

L0522-002 EA.

CKT 3 WHT= NEGATIVE BATT. TERMINAL

LA1073-00

BY

ENGLISH (TOLERANCE UNLESS SPECIFIED)

12/3/03THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

6

STOP

WATER

CKT 1 BLK= HOUSE BATTERY POS.

WATER

BLK

WHT

CKT 5 BRN= BLACK WATER TANK SENSOR

REL

WATER

LOAD

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

1

SEE NOTE 4.

CKT 13 YLW= D.S.I. WTR. HTR. POS.

NONE

SHOWN APPROX. 2X SCALE

LA1073-00

L0844-002 EA.

(MFG DATE)

CC0558-00

LEVELS

FUNCTION DRAWING,

C

WATER

All Rights Reserved, including the right to reproduce this document or any part thereof

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVING

1 PL. .020

L0118-00

DWG. NO.

CHG

L0118-00

CHG.

2/3

L0111-00

2. REF. DWG.'S:

L5131-02 1

BLK

GENERATOR

HARNESS, INTERNAL & SWITCH= L7752-00

L5131-02

SWITCH, DUMMY

CONFIDENTIAL

LABEL

PILOT OUT

START

1

HOLD START UNTIL

LA10

73-0

0L0531-00

PA

GE

2 O

F 2

SILKSCREENED CHASSIS

1

L0451-00

FOR USE WITH

WHT

LEVELS

2/3

TEST

LTR.

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

1

VD0169-00

DRAWN DATE

DESCRIPTION

3 PL. .005

15

CUSTOMER WIRING

0 PL. .040

L0115-00

PHILIPS IND. INC.

CC0558-00

WATER

LA1073-00

1

DETAIL -B

PCB SPACER

L0451-00

E

F

HOLE PLUG

SWITCH, SPST MOM. (ON)-OFF, BLK

3

L0115-00

BLACK

1/31/3

BATT

1/3

B

GREY

L0111-00

1/3 L5131-02

WATER

SEE DETAIL -B OR -C

1

A RJL

FRESH

OFF

TEST BOX= L8506-00

L1049-00

PUMP

PAGE 2 OF 2

MPR

RJL

VENTLINE WIRING

L.P.E

13ON

L7752-00

WHT

HARNESS, TEST= L7753-00

HEATER

PRODUCT LABELPRINTING DETAIL

NO SCALE

HEX NUT, 6-32

1

1

VD0169-00 TIE WRAP ON RIGHT SIDE POST.

HEATER

F

7

(MFG DATE)

WHT

1

2/3

NON-CONTACT

1a

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

11/21/03

L0531-002 EA.

RJL

PUMP ON

12

RJL

WATER

4. BEFORE PACKING, SECURE HARNESS WITH

PUMP

L0109-00

E

GAS

SWITCH, SPST ON-OFF, BLK, GRN LT.

ADDED LABEL DETAIL ECN 16381

E

9

2/3

SERVED THE PURPOSE FOR WHICH DELIVERED.

L5131-02 WAS L5118-02 ECN 16394

ECN 16261

4

F

4-21-04

GENERATOR STARTS

PCB

RED

2

SEE DETAIL -A

MPR

MPR

MPR

MONITOR PANEL

TO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

CKT 9 14-WHT/RED= WATER PUMP REMOTE SW.

SENSORS

LEVELS

4-6-04

4

8

WHT

CKT 4 RED= FRESH WATER TANK SENSOR

CKT 7 14-RED/WHT= WATER PUMP REMOTE SW.

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

L0393-05(REF.)

1b

FOR USE WITHNON-CONTACT

+12 V

WINNEBAGO

CKT 8 14-RED= WATER PUMP

BLK

CKT 6 GRY= GREY WATER TANK SENSOR

YLWGND

WATER

DETAIL -A

RELEASED TO PURCHASING & PRODUCTION

CKT 15 WHT/BLU= WTR. HTR. PILOT LT.

11/21/03 SEE BOM PAGE 2

THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

J

WHT

PCB

NOTES:

5

FIBER WASHER

1b

L0522-00

1

USEDBLANK

DISPLAY ON WHEN

6.25(REF.)

ONHEATER

PCB= L5131-02

CHK.

A

2 PL. .010

TEST

MATERIAL

NAMECHECKED DATE

BY

CC0558-00

DATE

L0522-00 1 EA

MATERIAL

SEE NOTE 4.

1

CKT 12 WHT/GRN= LP GAS TANK

1

SWITCH, SPDT ON-ON, BLK

L1049-00

DWG SIZE

GENERATOR RUNS

SHOWN APPROX. 2X SCALEVD0169-00 1 EA

FRACTIONS 1/64

VENTLINE DIVISION

HARNESS, INTERNAL & SWITCH

1a

TIE WRAP WITH POST HOLE

F

PART NO.

SIZE

134940 09-Mar-2015

Page 10: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

05 D SERIES

9

134940

PANEL-MONITOR

1/3

MPR

WATER HEATER

PUMP ON

MALE

HARNESS, SOLAR LIGHT= L7722-00

NONE

BY THIRD PARTY VENDOR

9

MALE

6.25(REF.)

GENERATOR

A

BLANK

E

MPR

BLACK TANK

RJL

MALE

GRN= SOLAR-IN GND.

GENERATOR STARTSSOLAR HOLD START UNTIL

PAGE 1 OF 2

SEE SHEET 2 ECN 16381

1

+

STOP

MALE

START

FEMALE

2

3

1

RED= GENERATOR POSITIVE

1/3

REL

NOTES:

GAS

USED

BY

2/3

DWG. NO.

13

CHK.

RED= ENGINE BATTERY POS.

1/3

WATER

VENTLINE DIVISION

2

BRISTOL, INDIANA 46507

1/3

F

All Rights Reserved, including the right to reproduce this document or any part thereof

SCALE:

2

WATER TANK

ON

4-21-04

2

CUSTOMER WIRING

DWG SIZE

LP GAS TANK

PUMP

YLW= SOLAR-IN

CHG.

DRAWN DATE

4

HARNESS, GEN. INTERNAL & SWITCH= L7786-00

1/10FEMALE

SEE BOM PAGE 2

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

HARNESS, INTERNAL & SWITCH= L7752-00

FULL

1

RJL

HOUSE BATTERY

BY

6

-

2/3

TEST BOX= L8506-00

B

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

BRN= HOLDING TANK 1 SENSOR

E

VD0169-00 TIE WRAP ON RIGHT SIDE POST.

2/3

DATE

SIZE

YLW= D.S.I. WTR. HTR. POS.

WHT= NEGATIVE BATT. TERMINALS

HARNESS, TEST= L7753-00

1

BLK= HOUSE BATTERY POS.

VENTLINE WIRING

WATER PUMP

21

1/3

FRACTIONS 1/64

L.P.

14-WHT/RED= WATER PUMP REMOTE SW.

2

FEMALE

2/3

1

3 PL. .005

11/21/03

WATER

ECN 16261

LTR.

TEST

WHEN

RJL

4 CKT CONN.

WHT/GRN= LP GAS TANK +

BRN= GENERATOR STOP

FULL

8

DISPLAY ON WHEN

2 CKT CONN., (2)

15 CKT CONNECTOR

PA

GE

1 O

F 2

ENGINE BATTERY

1/3

GRY= HOLDING TANK 2 SENSOR

CHARGING

2/3

HOURS

2/3

WHT/BLU= WTR. HTR. PILOT LT.

GREY TANK

BATT 3

CHG

TANK SENSOR ARRAYS SUPPLIED

-

4-6-04

7

RED= SOLAR-OUT

RED= FRESH WATER TANK SENSOR12

L5131-02 WAS L5118-02 ECN 16394

LIT

BLK= GENERATOR NEGATIVE

YLW= GENERATOR START

BLK= SOLAR-OUT GND.

SOLAR UNIT

8.25(REF.)

MONITOR PANEL

REQ'D

2. REF. DWG.'S:

ENGLISH (TOLERANCE UNLESS SPECIFIED)

15

APPV'D DATE

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER. WINNEBAGO

DESCRIPTION

14-RED/WHT= WATER PUMP REMOTE SW.

MATERIAL

F

TO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

4

GENERATOR RUNS

CHASSIS GROUND

5

PART NO.

RJL

FEMALE

1

2

1/3

FULL

CHECKED DATE

1 PL. .020

14-RED= WATER PUMP SW.

4. BEFORE PACKING, SECURE HARNESS WITH

LA1074-00

DESCRIPTION

BLACK

MATERIAL

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVING

OFF

F

2/3

FUNCTION DRAWING,MPR

WATER

PCB= L5131-02

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

LEVELSHEATER

NAME

GREY

CONFIDENTIALTHIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

PILOT OUT

2 PL. .0100 PL. .040

MPR

FRESH

SERVED THE PURPOSE FOR WHICH DELIVERED.

RELEASED TO PURCHASING & PRODUCTION.

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

ON

F

12/3/03

WATER

E

WATER

C

E

11/21/03

PHILIPS IND. INC.

LA10

74-0

0

134940 09-Mar-2015

Page 11: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

05 D SERIES

10

134940

PANEL-MONITOR

CKT 6 GRY= GREY WATER TANK SENSOR

L0775-00

MPR

FOR USE WITH

APPV'D DATE

L0775-00

OFF

HARNESS, INTERNAL & SWITCH= L7752-00

GENERATOR STARTS

BLK

TEST

2/3

L7751-00

PUMP ON

4

SOLAR LIGHT PCB

L0109-00

SWITCH, SPDT ON-ON, BLK

SHOWN APPROX. 2X SCALE

GAS

L0522-00

WATER

MATERIAL

SCALE:

1a

E

HEX NUT, 6-32

1 SWITCH, SPST MOM. (ON)-OFF, BLK

PCB SPACER

MONITOR PANEL

THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

FIBER WASHER

1a

1b

F

PAGE 2 OF 2

L0111-00

1/3

1

1

E

11/21/03

DRAWN DATE

1

L0531-00

L0109-00

L0522-002 EA.

USED

VENTLINE DIVISION

L0112-00

1

SHOWN APPROX. 2X SCALE

2

NONE

1b

SERVED THE PURPOSE FOR WHICH DELIVERED.

3 PL. .005

CHG.

C

SEE DETAIL -A

WATER

L.P.

L0393-05(REF.)

F

DETAIL -B

CHG

WINNEBAGO

WHT

L5131-02

WATER

+12 V

1

2

SEE BOM

CKT 1 BLK= HOUSE BATTERY POS.

HARNESS, SOLAR LIGHT= L7722-00PRODUCT LABELPRINTING DETAIL

NO SCALE

WHT

VENTLINE WIRING

RELEASED TO PURCHASING & PRODUCTION

CKT 3 BRN= GENERATOR STOP

CKT 13 YLW= D.S.I. WTR. HTR. POS.

L0522-00 1 EA

CKT 2 YLW= GENERATOR START

LEVELS

WATER

DESCRIPTION

FRACTIONS 1/64

BY

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVING

ENGLISH (TOLERANCE UNLESS SPECIFIED)

TO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

All Rights Reserved, including the right to reproduce this document or any part thereof

CONFIDENTIAL

PCB

NON-CONTACT

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

LTR.

LA1074-00

F

HEATER

SEE DETAIL 'A'

MPR

11/21/03

CKT 8 14-RED= WATER PUMP

SENSORS

PCB= L5131-02

WHT

CKT 9 14-WHT/RED= WATER PUMP REMOTE SW.

CKT 7 14-RED/WHT= WATER PUMP REMOTE SW.

LA1074-00

L0531-002 EA.

CHECKED DATE

MALE

CKT 4 BLK= GENERATOR NEGATIVE

DATE

BRISTOL, INDIANA 46507

_

FEMALE

REL

RJL

1

L7722-00

1

MALE

L7752-00

CKT 1 RED= GENERATOR POSITIVE

CKT 4 RED= FRESH WATER TANK SENSOR

FOR USE WITH

CKT 12 WHT/GRN= LP GAS TANK

(MFG DATE)

1/3

ECN 16261

WHT

GRN = SOLAR-IN GND

CKT 3 WHT= NEGATIVE BATT. TERMINAL

1/3

L5131-02 WAS L5118-02 ECN 16394

WATER

2. REF. DWG.'S:

1

MALE

MALE

1

TEST BOX= L8506-00

4

9

1

13

SWITCH, SPST ON-OFF, BLK, GRN LT.

YLW

VD0169-00 1 EA

VD0169-00 TIE WRAP ON RIGHT SIDE POST.

FEMALE

NOTES:

TEST

PUMP

12

TIE WRAP

1/3

PA

GE

2 O

F 2

1

DWG SIZECE0136-00

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

A

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

4

15

B

WHT

CKT 15 WHT/BLU= WTR. HTR. PILOT LT.

RJLRJL

4. BEFORE PACKING, SECURE HARNESS WITH

SOLAR LIGHT HARNESS

LA1074-00

ADDED LABEL DETAIL ECN 16381

PART NO.

CE0136-00

1

L5131-02DETAIL -A

HOBBS HOUR METER

FUNCTION DRAWING,0 PL. .040

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

1 PL. .020

MPR

CHK.

1

3

CUSTOMER WIRING

HARNESS, GENERATOR

2

5

L7751-00

4-21-04

GREY

STOP

PHILIPS IND. INC.

DWG. NO.

4-6-04

RJL

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

SEE NOTE 3.

8

12/3/03

HEATER

1

2/3

HARNESS, TEST= L7753-00

CKT 5 BRN= BLACK WATER TANK SENSOR

2 CKT CONN. (2)

SIZE

CE0136-00

L0451-00

L0844-002 EA.

WATER

BLANK

MPR

FEMALE

6

HARNESS, GEN. INTERNAL & SWITCH= L7786-00

A

3

VD0169-00

HARNESS, INTERNAL & SWITCH

7

2 PL. .010

ON

NAME

REQ'D DESCRIPTION

LEVELS

MATERIAL

LEVELS

HOURS

NON-CONTACT

GENERATOR RUNS

SOLAR

2/3

SEE NOTE 4.

L0115-00

LIT

E

8.25(REF.)

RED

L0112-00

4

WHT

LOAD

BLACK

WHEN

YLW = SOLAR-IN

TEST

L0111-00

+

CHARGING

BLKLA

1074

-00

R

WATER

BY

HOLD START UNTIL

ON

LABEL1

BLK = SOLAR-OUT GND

1

SILKSCREENED CHASSIS

SENSORS

WATER

F

2/3

START

L0115-00

1

PILOT OUT

SEE DETAIL -B

L0451-00

E

PCB

DISPLAY ON WHEN

L0844-00

GND

FRESH

L5131-02

HEATER

RED = SOLAR-OUT

1

L7752-00

BATT

FEMALE

PUMP

SEE NOTE 4.

E

SWITCH, SPDT (ON)-OFF-(ON), BLK

5

L5121-01

1/10

BLK

134940 09-Mar-2015

Page 12: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

06 500 SERIES

11

134940

PANEL-MONITOR

GENERATOR STARTS

YLW= GENERATOR START

BY THIRD PARTY VENDOR

STOP

12/3/03

2. REF. DWG.'S:

DESCRIPTION

ECN 16261

1

B RJL

RJLA

2/3

ON

TO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

0 PL. .040

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

2/3

2

CHASSIS GROUND

BRN= GENERATOR STOP4

GENERATOR

10

WATER PUMP

HARNESS, SOLAR LIGHT= L7722-00

BATT

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

LP GAS TANK

MATERIAL

E

1/3

DWG SIZE

MALE

DRAWN DATE

1/3

MALE

PART NO.

WATER

LEVELSHEATER

BLANK

SERVED THE PURPOSE FOR WHICH DELIVERED.

ENGLISH (TOLERANCE UNLESS SPECIFIED)

FEMALE

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

E

4-6-04

REQ'D

LA10

75-0

0

HARNESS, TEST= L7753-00

START

E

VENTLINE DIVISION

RJL

2/3

2/3

7

FULL

-

WHT/BLU= WTR. HTR. PILOT LT.

2 PL. .010

N.C.

9

DATE

BLACK

ENGINE BATT.

USED

FEMALE

PUMP

F

4 CKT CONNECTOR

14-RED/WHT= WATER PUMP REMOTE SW.

RELEASED TO PURCHASING AND PRODUCTION

F

2

NONE

BRISTOL, INDIANA 46507

CHG

1

BLK= GENERATOR NEGATIVE

MATERIAL

2

FRESH

PILOT OUT

MPR

C

CUSTOMER WIRING

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVING

+

WATER

BLACK TANK

1/3

LTR. CHG.

WATER TANK

14-WHT/RED= WATER PUMP REMOTE SW.

6

2/3

F

3 PL. .005

RED= FRESH WATER TANK SENSOR

GREY

1

CHK.

GREY TANK

3

6.25(REF.)

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

MONITOR PANEL

FULL

HARNESS, INTERNAL & SWITCH= L7752-00

BY

PA

GE

1 O

F 2

11

REL

1/3

MPR

1/3

VD0169-00 TIE WRAP ON RIGHT SIDE POST.

MPR

2/3

5

SEE SHEET 2 ECN 16381

4-21-04L5131-02 WAS L5118-02 ECN 16394

RJL

MPR

CONFIDENTIAL

N.C.

FRACTIONS 1/64

WHT= NEGATIVE BATT. TERMINAL

12

REMOTE SWITCH

TANK SENSOR ARRAYS SUPPLIED

ON

CHECKED DATE

WATER PUMP

4

All Rights Reserved, including the right to reproduce this document or any part thereof

2

E

1 PL. .020

OFF

WINNEBAGO

FUNCTION DRAWING,

WATER

14

PUMP ON

3

1

BY

WATER HEATER

2/3

BRN= BLACK WATER TANK SENSORGRY= GREY WATER TANK SENSOR

PAGE 1 OF 2

WATER

N.C.

11/21/03

HOLD START UNTIL

VENTLINE WIRING

GAS

TEST BOX= L8506-00

14-RED= WATER PUMP

PCB= L5131-02

WATER

8.25(REF.)

NOTES:

NAME

HARNESS, GEN. INTERNAL & SWITCH= L7786-00

SEE BOM PAGE 2

DWG. NO.

SCALE:

THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

11/21/03

15 CKT CONNECTOR

N.C.

SIZE

8

GENERATOR

WHT/GRN= LP GAS TANK

1/3

F

1

APPV'D DATE

4. BEFORE PACKING, SECURE HARNESS WITH

LA1075-00

PHILIPS IND. INC.

TEST

1/3

15

YLW= D.S.I. WTR. HTR. POS.

2

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

13

DESCRIPTION

FULL

BLK= HOUSE BATTERY POS.L.P.

134940 09-Mar-2015

Page 13: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

06 500 SERIES

12

134940

PANEL-MONITOR

YLW

CKT 3 BRN= GENERATOR STOP

CKT 9 14-WHT/RED= WATER PUMP REMOTE SW.

L7752-00

REL

DETAIL -B

LA1075-00START

L0393-05(REF.)

SHOWN APPROX. 2X SCALE

ENGLISH (TOLERANCE UNLESS SPECIFIED)

2

BY

HEATER

SEE NOTE 4.

HARNESS, INTERNAL & SWITCH

2/3

ECN 16261

CONFIDENTIAL

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.

1

WHT

L0109-00

15

1

1

NOTES:

0 PL. .040

RJL

6

1

1/3

LEVELS

2

E

MONITOR PANEL

GEN.

4-21-04

1/3

1

13

CHG.

L0115-00

1/3

NON-CONTACT

HARNESS, GENERATOR

1

SWITCH, SPDT ON-ON, BLK

NAME

BLANK

CKT 1 BLK= HOUSE BATTERY POS.

1a

FUNCTION DRAWING,

THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

SWITCH, SPST ON-OFF, BLK, GRN LT.

MPR

CHECKED DATE

REQ'D

WHT

1 PL. .020

STOP

DETAIL -A

WATER

WHT

2/3

HEATER

WHT

SEE DETAIL -B

PUMP

E

PCB

PUMP

F

WATER

F

2/3

WATER

LA1075-00

BATT

DESCRIPTION

MATERIAL

2 PL. .010

SWITCH, SPST MOM. (ON)-OFF, BLK

PART NO.

L.P.

L5131-02 WAS L5118-02 ECN 16394

BLK

L0451-00PCB SPACER

CE0150-00

FOR USE WITH

VD0169-00 TIE WRAP ON RIGHT SIDE POST.

1

DWG SIZE

PAGE 2 OF 2

2/3

GENERATOR STARTS

1a

3

MPR

L7832-00

SWITCH, SPDT (ON)-OFF-(ON), BLK

WHT

4

4. BEFORE PACKING, SECURE HARNESS WITH

L5131-021

BLACKWATER

RJL

VENTLINE WIRING

B

CUSTOMER WIRING

1

8

SENSORS

L0111-00

L7832-00

HARNESS, GEN. INTERNAL & SWITCH= L7786-00

VD0169-00

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

CKT 13 YLW= D.S.I. WTR. HTR. POS.

A

HARNESS, TEST= L8012-00

HARNESS, INTERNAL & SWITCH= L7785-01, -02

1

TEST BOX= L8506-00

PRODUCT LABELPRINTING DETAIL

NO SCALE

FIBER WASHER

3 HEX NUT, 6-32

1

RJL

7

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

LABEL

PCB

L0522-00

5

1

FOR USE WITH

6.25(REF.)

F

PA

GE

2 O

F 2

LEVELS

1

9

GREY

BRISTOL, INDIANA 46507

L0112-00

A 4-6-04

WHT

PCB= L5131-02

2. REF. DWG.'S:

F

PUMP ON

TEST

TEST

L0115-00

SHOWN APPROX. 2X SCALE

SEE NOTE 4.

WATER

L0112-00

NON-CONTACT

12

DESCRIPTION

L0844-00

CE0150-00

L0531-00

L0451-00

3

3 PL. .005 LA1075-00

E

TIE WRAP

L7752-00

L5131-021/3

L0111-00

SEE DETAIL -A

ON

GENERATOR

HOLD START UNTIL

CE0150-00

WATER

1

CHGFRESH

RED

WATER

1b

SENSORS

8.25(REF.)

E

L0109-00

GAS

SILKSCREENED CHASSIS

MPR

SERVED THE PURPOSE FOR WHICH DELIVERED.

C

L0522-00 1 EA

L5131-02

LOAD

CKT 4 RED= FRESH WATER TANK SENSOR

HEATER

CKT 1 = NOT USED

CKT 5 BRN= BLACK WATER TANK SENSOR

GND

SEE BOM

BLK

VD0169-00 1 EA

TEST

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

CKT 4 BLK= GENERATOR NEGATIVE

LA10

75-0

0

DWG. NO.

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVING

ADDED LABEL DETAIL ECN 16381

RJL

DATE

2

DRAWN DATE

4

SIZE

FRACTIONS 1/64

(MFG DATE)

BY

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

11/21/03

WINNEBAGO

NONE

CKT 3 WHT= NEGATIVE BATT. TERMINAL

CKT 8 14-RED= WATER PUMP

L0844-002 EA.

USED

APPV'D DATE

LTR.

L0531-002 EA.

CKT 6 GRY= GREY WATER TANK SENSOR

CHK.

MATERIAL PHILIPS IND. INC.

CKT 2 YLW= GENERATOR START

VENTLINE DIVISION

SCALE:

OFF

CKT 7 14-RED/WHT= WATER PUMP REMOTE SW.

+12 VBLK

LEVELS

1b

WATER

TO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

PILOT OUT

ON

All Rights Reserved, including the right to reproduce this document or any part thereof

MPR

RELEASED TO PURCHASING AND PRODUCTION

11/21/03

CKT 15 WHT/BLU= WTR. HTR. PILOT LT.

12/3/03

L0522-002 EA.

CKT 12 WHT/GRN= LP GAS TANK

134940 09-Mar-2015

Page 14: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

134940

PANEL-MONITOR 2-TANK13

300 & F SER

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

All Rights Reserved, including the right to reproduce this document or any part thereof

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVINGTO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

CONFIDENTIAL

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

SERVED THE PURPOSE FOR WHICH DELIVERED.

C

APPV'D DATE

CHECKED DATE

DRAWN DATESIZEBLANK

PART NO.

NAME

MATERIAL

MATERIALREQ'D DWG SIZE

DRAWING NO.

SCALE:

DESCRIPTION

USEDON

DIVISION OF PHILIPSBRISTOL, INDIANA 46507

ECN LTR. DESCRIPTION CHK.DATE CHG.BY BY

TOLERANCE UNLESS OTHERWISE SPECIFIED

UNITS OF MEASURE: INCHES UNLESS SPECIFIED

0.00 = 0.000 =

0.0 =

ANGLES = FRACTIONS =

LA1086-00FUNCTION DRAWING

MONITOR PANEL

MRH 04/26/07

MRH 04/26/07NONE

SEE PAGE 2

WINNEBAGO

a RELEASE FOR QUOTE AND SAMPLE 04/26/07 MRH MRH

LA10

86-0

0

.020

.010

.005

1/16 1

BLACK TANK

WATER PUMP

CHASSIS GROUND

ENGINE BATT.

VENTLINE WIRING

14-WHT/RED= WATER PUMP REMOTE SW.

WHT= NEGATIVE BATT. TERMINAL

14-RED/WHT= WATER PUMP REMOTE SW.

WHT/BLU= WTR. HTR. PILOT LT.

BLK= HOUSE BATTERY POS.

WHT/GRN= LP GAS TANK

14-RED= WATER PUMPYLW= D.S.I. WTR. HTR. POS.

N.C.14

CUSTOMER WIRING

+ -

15

10

11 N.C.

N.C.

N.C.2

1

3

12

13

8

7

9

WATER HEATER

RED= FRESH WATER TANK SENSOR

GRY= GREY WATER TANK SENSORBRN= BLACK WATER TANK SENSOR

15 CKT CONNECTORMALE

6

5

4

FEMALEWATER TANK

2/31/3

21

FULL1

REMOTE SWITCHLP GAS TANKWATER PUMP

BY THIRD PARTY VENDOR

2/31/3

GREY TANK

2/31/3

FULL2

FULL21

TANK SENSOR ARRAYS SUPPLIED

*VISUALLY CHECK EACH PANEL FOR A RED CIRCUIT BOARD THAT IS THE SPECIFIED PART NUMBER*

C

PCB= L5131-02

2. REF. DWG.'S:

4. BEFORE PACKING, SECURE HARNESS WITH VD0169-00 TIE WRAP ON RIGHT SIDE POST.

HARNESS, TEST= L7753-00

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

HARNESS, INTERNAL & SWITCH= L7752-00

TEST BOX= L8506-00

NOTES:

PA

GE

1 O

F 2

(REF.)6.00

L.P. BATTGREYBLACK FRESHWATERWATER GASWATER CHG

FFF F

2/3

1/31/3

E

2/3

1/3 1/3

EE E

2/3 2/3

PILOT OUT

OFF

PUMP ON

HEATERON

WATERTEST PUMP

LEVELS WATER

6.25(REF.)

PAGE 1 OF 2

134940 09-Mar-2015

Page 15: If you lack the skills, tools or equipment to perform ...14-red/wht= water pump remote sw. red= fresh water tank sensor 14-wht/red= water pump remote sw. fresh l.p. batt water generator

A

2

C

DO NOT SCALE DRAWING

D

PART NO

C

DWGNO

1

REV

5

5

A

4

D

16

8

B

3

7

TITLE:

SHEET

8

3 2

7

6

4

B

FIRST USED

300 & F SER

14

134940

PANEL-MONITOR 2-TANK

134940

All Rights Reserved, including the right to reproduce this document or any part thereof

THE DOCUMENT AND INFORMATION ARE NOT TO BE COPIED, REPRODUCED OR DELIVERED

VENTLINE. THE DOCUMENT IS TO BE RETURNED PROMPTLY TO VENTLINE AFTER HAVINGTO OTHERS, IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN PERMISSION OF

AND CONFIDENTIAL PROPERTY OF VENTLINE DIVISION OF TOMKINS INDUSTRIES INC.THIS DOCUMENT, INCLUDING ALL INFORMATION CONTAINED HEREIN, IS THE EXCLUSIVE

CONFIDENTIAL

1995 VENTLINE DIVISION, TOMKINS INDUSTRIES, INC.

SERVED THE PURPOSE FOR WHICH DELIVERED.

C

APPV'D DATE

CHECKED DATE

DRAWN DATESIZEBLANK

PART NO.

NAME

MATERIAL

MATERIALREQ'D DWG SIZE

DRAWING NO.

SCALE:

DESCRIPTION

USEDON

DIVISION OF PHILIPSBRISTOL, INDIANA 46507

ECN LTR. DESCRIPTION CHK.DATE CHG.BY BY

TOLERANCE UNLESS OTHERWISE SPECIFIED

UNITS OF MEASURE: INCHES UNLESS SPECIFIED

0.00 = 0.000 =

0.0 =

ANGLES = FRACTIONS =

LA1086-00FUNCTION DRAWING

MONITOR PANEL

MRH 04/26/07

MRH 04/26/07NONE

SEE BOM

WINNEBAGO

17148 REL RELEASE TO PURCHASING & PRODUCTION 05/10/07 MRH MRH

LA10

86-0

0

.020

.010

.005

1/16 1

SENSORSNON-CONTACT

(MFG DATE)

FOR USE WITH

NOTES:

HARNESS, INTERNAL & SWITCH= L7752-00

TEST BOX= L8506-00

3. ALL PIGTAILS TO BE SUPPLIED BY CUSTOMER.

VD0169-00 TIE WRAP ON RIGHT SIDE POST.4. BEFORE PACKING, SECURE HARNESS WITH

HARNESS, TEST= L7753-00

1. UNLESS OTHERWISE SPECIFIED ALL WIRE IS 22 AWG.

PCB= L5131-02

2. REF. DWG.'S:

PRODUCT LABELPRINTING DETAIL

NO SCALE

LA1086-00

FOR A RED CIRCUIT BOARD THAT IS THE SPECIFIED PART NUMBER**VISUALLY CHECK EACH PANEL

L0522-002 EA.

SEE NOTE 4.

L0531-002 EA.

L0844-002 EA.

L0393-05(REF.)

SHOWN APPROX. 2X SCALEDETAIL -A

L5131-02

CE0129-00

VD0169-00 1 EA

L0522-00 1 EA

WHT

HEATERTESTLEVELS

WHT

WATER

1a +12 VBLKWHT

1LOAD

1bGND

BLK

YLW

DETAIL -BSHOWN APPROX. 2X SCALE

WHT

L5131-021/3 1/3 1/3 1/3

SEE DETAIL - A

BATTE

GREYBLACKWATER WATER

EL.P.FRESHGASWATER CHG

E E

CE0129-00

L0109-00

L0451-00

F

2/32/3

F

2/3 2/3

F F

OFF

PILOT OUT

HEATERON

PUMP ON

TEST PUMPLEVELSWATER WATER

L0115-00

L0111-00

DATE

(REF.)6.000

PCB

6.25(REF.)

PART NO./

4CKT 4 RED= FRESH WATER TANK SENSOR

CKT 5 BRN= BLACK WATER TANK SENSORCKT 6 GRY= GREY WATER TANK SENSOR

5

6

CKT 8 14-RED= WATER PUMP

CKT 7 14-RED/WHT= WATER PUMP REMOTE SW.

CKT 9 14-WHT/RED= WATER PUMP REMOTE SW.

CKT 13 YLW= D.S.I. WTR. HTR. POS.

CKT 15 WHT/BLU= WTR. HTR. PILOT LT.CKT 1 BLK= HOUSE BATTERY POS.

CKT 12 WHT/GRN= LP GAS TANK

CKT 3 WHT= NEGATIVE BATT. TERMINAL

L7752-00

1

15

12

13

3

VENTLINE WIRING

8

7

9

CUSTOMER WIRING

WHTBLK

WHT

PUMPWATER

TESTLEVELS WATER

HEATER

RED

1a

1

1b

SEE DETAIL -B OR -C

PA

GE

2 O

F 2

PAGE 2 OF 2

L0115-00 1 SW, SPDT ON-ON, BLK

L7752-00 1 INTERNAL & SWITCH HARNESSL5131-02 1 PCB

CE0129-00 1 SILKSCREENED CHASSIS

VD0169-00 1 TIE WRAP

L0111-00 1 SW, SPST MOM. (ON)-OFF, BLK

L0844-00 2 PCB SPACER

L0451-00 1 LABEL

L0531-00 2 FIBER WASHER

L0522-00 3 HEX NUT, 6-32

L0109-00 1 SW, SPST ON-OFF, BLK, GRN LT.

09-Mar-2015