IET600 Integrated Engineering Tool Ver. 5.3 IEC 61850 System ...

2
IET600 Integrated Engineering Tool Ver. 5.3 IEC 61850 System Integration Features IEC 61850 oriented project explorer for fast navigation within a project / substation Primary objects view Communication subnetworks view IED view HMI view Default support for primary and secondary equipment naming scheme according IEC 81346 Station wide consistent IEC 61850 dataflow configuration View or engineer dataset and dataflow configuration, for vertical or horizontal IEC 61850 communication Comprehensive matrix for efficient and flexible configuration of MMS client server reporting GOOSE publisher/subscriber Sampled values publisher/subscriber Configuration of IEC 61850 substation to substation communication Configuration of IEC 61850 functions & sub-functions Freely adaptable tool behavior for handling IEC 61850 IED capabilities for higher engineering tool interoperability Transparent IEC 61850 configuration comparison when importing SCL files Graphical editor for single line diagram bay oriented voltage level oriented including IEC 61850 logical node mapping to primary equipment & functions Graphical editor for network configuration diagram covering and supporting IEDs, HMIs, Gateways Ethernet switches Switch configuration according to IEC 61850-90-4 Integral communication address configuration tables HMI database maintenance for ABB MicroSCADA Pro SYS600/C based substation automation systems Powerful copy/paste functions for single or multiple HMI signals IEC 61850 IEDs Grafical bay single line diagram Fully engineered bays including IEDs, single line diagram, logical node mapping, ABB MicroSCADA Pro SYS600/C database signals Seemless migration of projects from the predecessor versions Supported file exchange formats for ABB MicroSCADA SYS600/C *.lof/*.csv database load file (complete) *.sfx file database load file (changes only) *.xrf/*.txt gateway configuration files *.xls database documentation Supported IEC 61850 file fomats SCL import SCD, ICD, CID, IID SED (SCL version 2007 Rev.B) SCL export SCD, ICD, IID SED (SCL version 2007 Rev.B) *.xls export for documentation of complete IEC 61850 dataflow Supported IEC 61850 SCL scheme versions 2003 Rev.A 2007 Rev.B

Transcript of IET600 Integrated Engineering Tool Ver. 5.3 IEC 61850 System ...

Page 1: IET600 Integrated Engineering Tool Ver. 5.3 IEC 61850 System ...

IET600 Integrated Engineering Tool Ver. 5.3IEC 61850 System Integration

Features• IEC 61850 oriented project explorer for fast navigation

within a project / substation − Primary objects view − Communication subnetworks view − IED view − HMI view

• Default support for primary and secondary equipment naming scheme according IEC 81346

• Station wide consistent IEC 61850 dataflow configuration − View or engineer dataset and dataflow configuration,

for vertical or horizontal IEC 61850 communication − Comprehensive matrix for efficient and flexible

configuration of − MMS client server reporting − GOOSE publisher/subscriber − Sampled values publisher/subscriber

− Configuration of IEC 61850 substation to substation communication

− Configuration of IEC 61850 functions & sub-functions − Freely adaptable tool behavior for handling IEC 61850

IED capabilities for higher engineering tool interoperability − Transparent IEC 61850 configuration comparison when

importing SCL files• Graphical editor for single line diagram

− bay oriented − voltage level oriented − including IEC 61850 logical node mapping to primary

equipment & functions• Graphical editor for network configuration diagram

covering and supporting − IEDs, HMIs, Gateways − Ethernet switches − Switch configuration according to IEC 61850-90-4

• Integral communication address configuration tables • HMI database maintenance for ABB MicroSCADA Pro

SYS600/C based substation automation systems• Powerful copy/paste functions for

− single or multiple HMI signals − IEC 61850 IEDs − Grafical bay single line diagram − Fully engineered bays including IEDs, single line diagram,

logical node mapping, ABB MicroSCADA Pro SYS600/C database signals

• Seemless migration of projects from the predecessor versions

• Supported file exchange formats for ABB MicroSCADA SYS600/C − *.lof/*.csv database load file (complete) − *.sfx file database load file (changes only) − *.xrf/*.txt gateway configuration files − *.xls database documentation

• Supported IEC 61850 file fomats − SCL import

− SCD, ICD, CID, IID − SED (SCL version 2007 Rev.B)

− SCL export − SCD, ICD, IID − SED (SCL version 2007 Rev.B)

• *.xls export for documentation of complete IEC 61850 dataflow

• Supported IEC 61850 SCL scheme versions − 2003 Rev.A − 2007 Rev.B

Page 2: IET600 Integrated Engineering Tool Ver. 5.3 IEC 61850 System ...

1MR

K51

1299

-SE

N 1

0/20

13

For more information please contact: ABB AB Substation Automation Products721 59 Västerås, Sweden Phone: +46 (0) 21 32 50 00

www.abb.com/substationautomation

Note:We reserve the right to make technical changes or modify the contents of this document without prior notice. ABB AB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.We reserve all rights in this document and in the subject matter and illustrations contained herein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in part – is forbidden without prior written consent of ABB AB.

© Copyright 2013 ABB. All rights reserved.

Scan this QR code to visit our website

System requirements

Hardware requirements

Hardware Minimum Recommended

CPU dual-core processor quad-core processor

RAM 3 GB 8 GB

Free hard disk space 300MB +

2.5GB page file size

4 GB

SSD drive

Monitor 1440 x 900 1600 x 1000 or higher

Supported operating system

Operating system Version

Microsoft Windows XP Professional 32-bit SP3

Microsoft Windows Server 2003 32-bit SP2

Microsoft Windows Server 2008 32-bit or 64-bit SP2

Microsoft Windows Vista Business 32-bit SP1

Microsoft Windows 7 Professional 32-bit or 64-bit

Microsoft Windows 8 Professional 32-bit or 64-bit