IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This...

12
STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government. This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0. IES LM-79-08 MEASUREMENT AND TEST REPORT For Shenzhen XinShengYang Opto-electronics Technology Co.,Ltd D Building, 1st Ind.Park, Fenghuang 3rd Ind. Zone, Fuyong, Bao’an District, Shenzhen, China Test Model: XSY-FLHP50W Report Type: Electrical and Photometric tests including: Luminous Flux, Color, Luminous Intensity Distribution Test Engineer: Daniel Duan Report Number: RSZ160118505-10 Test Date: 2016-01-22 to 2016-01-23 Report Date: 2016-01-26 Reviewed By: Jeanne Han/Safety Manager Prepared By: Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008 Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial Area, Tangxia Town, Dongguan, Guangdong, P.R.China. Accreditation: The NVLAP Lab Code is 200707-0.

Transcript of IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This...

Page 1: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

STATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.

(Shenzhen). The test data was only valid for the test sample(s). This report must not be used by the customer to claim product certification,

approval, or endorsement by NVLAP, NIST, or any agency of the U.S. Federal Government.

This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

IES LM-79-08 MEASUREMENT AND TEST REPORT

For

Shenzhen XinShengYang Opto-electronics Technology

Co.,Ltd D Building, 1st Ind.Park, Fenghuang 3rd Ind. Zone, Fuyong, Bao’an District, Shenzhen, China

Test Model: XSY-FLHP50W

Report Type: Electrical and Photometric tests including: Luminous Flux,

Color, Luminous Intensity Distribution

Test Engineer: Daniel Duan

Report Number: RSZ160118505-10

Test Date: 2016-01-22 to 2016-01-23

Report Date: 2016-01-26

Reviewed By: Jeanne Han/Safety Manager

Prepared By:

Bay Area Compliance Laboratories Corp. (Shenzhen)

6/F, the 3rd Phase of WanLi Industrial Building,

ShiHua Road, FuTian Free Trade Zone

Shenzhen, Guangdong, China

Tel: +86-755-33320018

Fax: +86-755-33320008

Test Facility: Test facility was located at Pu Long Cun 69, Puxinghu Industrial

Area, Tangxia Town, Dongguan, Guangdong, P.R.China.

Accreditation: The NVLAP Lab Code is 200707-0.

Page 2: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 2 of 12 The NVLAP Lab Code is 200707-0.

1. Product Description

General Information:

One sample was received on 2016-01-18 and used for testing.

Model Tested: XSY-FLHP50W

Manufacturer: Shenzhen XinShengYang Opto-electronics Technology Co.,Ltd

Brand Name: XSY

Product Designation: LED flood light

Burning Time Before Test: 0hour(For New Products)

Rated Values:

Rated Voltage/Frequency: 100-240VAC 50/60Hz

Rated Power: 50 W

Nominal CCT: 5000K

Nominal Lumen Output: 5500Im

2. Standards Used

IESNA LM-79-08: Approved Method: Electrical & Photometric Measurement of Solid-state Lighting Products

ANSI C82.77-2002: Harmonic Emission Limits – Related Power Quality Requirements for Lighting

3. Description of Test Equipment

Device Manufacture Model No Serial No Test Range Calibration

date

Calibration

due date

Integrating Sphere SENSING SPR-600 S09008 25~50℃ 2015-03-25 2016-03-24

Spectral

photometer SENSING SPR3000 90902027 350nm~800nm 2015-03-25 2016-03-24

Power Meter YOKOGAWA WT-210 91j926132 15/30/60/150/300/600 V 2015-03-05 2016-03-04

AC Power Supply ALL Power APW-

105N 970663 220V±10% 50HZ 2015-03-05 2016-03-04

Standard Light

Source EVERFINE D204 01331191 24V/100W 2015-08-27 2016-08-26

Thermal Meter SENSING N/A N/A 25、50℃ 2015-03-05 2016-03-04

DC Power Supply ITECH IT6154 0061 0417 6471 0010

19 0~32V 2015-03-05 2016-03-04

AC Power Supply EVERFINE VPS1030

PWM 1012017 0-150V, 0-300V 2015-03-05 2016-03-04

DC Power Supply EVERFINE WY12010 1009009 30V/5A 2015-03-05 2016-03-04

Power Meter YOKOGAWA WT-210 91KB35700 15/30/60/150/300/600 V 2015-03-05 2016-03-04

Goniophotometer EVERFINE GO-

R5000 YG108492N10120001 1600mm,3000W/10A 2015-03-20 2016-03-19

Wireless Remote

Sensor N/A 433MHz N/A 0℃~50℃;-20℃~60℃ 2015-03-24 2016-03-23

Standard Light

Source EVERFINE D908 1012003 N/A 2015-09-08 2016-09-07

Page 3: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 3 of 12 The NVLAP Lab Code is 200707-0.

Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attested that all calibration has been performed using suitable standards traceable to National Primary Standards and International System of Units (SI).

4. Test Method

Product was tested with no seasoning. All stabilization and measurements were made in compliance with IES LM-79-08. The product was operated at rated voltage or at voltage required by manufacturer. The ambient temperature of the sample was maintained at 25°C±1°C during measurement. And relative humidity is less than 65%.

Integrating Sphere System

The system includes AC power source, digital power meter, DC power supply, spectrophotometer, and integrating sphere. The integrating sphere system is calibrated by standard light source before measurement.

4π geometry was used during measurement. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the light output (luminous flux) measurements is U=2.1% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=32K (K=2), at the 95% confidence level. The uncertainty of the CRI is U=2.1 (K=2) , at the 95% confidence level. The uncertainty of power meter AC current U=0.19 % of rdg, AC Voltage U=0.15% of rdg, Power U=0.20%) (K=2), at the 95% confidence level.

Goniophotometer System

The goniophotometer system is calibrated by standard light source before measurement.

Type C goniophotometer was used for measuring total luminous flux, luminous intensity distribution, and color spatial

uniformity. The product was operated in its intended orientation in application and was recorded in this report.

The uncertainty of the luminous intensity is U=2.82% (K=2) , at the 95% confidence level.

Page 4: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 4 of 12 The NVLAP Lab Code is 200707-0.

5. Test Result

[Integrating Sphere System]

Total operating time for integrating sphere test: 1.0 hour

Test orientation: Downward

Electrical Measurement

Voltage (V) Frequency (Hz) Current (A) Power (W) Power Factor

240.04 50 0.2239 51.15 0.952

Photometric Measurement

Luminous Flux (lm) Radiant Flux (W) Efficacy (lm/W) CCT (K) Duv

5927.498 17.840 115.885 4912 0.0006

Chromaticity Coordinate

x y u v u' v'

0.3478 0.3550 0.2119 0.3245 0.2119 0.4867

Color Rendering Index

Ra

74.8

R1 R2 R3 R4

73 80 84 75

R5 R6 R7 R8

72 71 84 60

R9 R10 R11 R12

-17 51 71 42

R13 R14 R15

75 90 68

Page 5: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 5 of 12 The NVLAP Lab Code is 200707-0.

Relative Spectral Power Distribution

nm mW nm mW nm mW nm mW nm mW

380 2.532E-03 465 2.604E-01 550 4.110E-01 635 2.386E-01 720 2.555E-02

385 9.222E-04 470 1.842E-01 555 4.122E-01 640 2.154E-01 725 2.234E-02

390 6.438E-04 475 1.241E-01 560 4.239E-01 645 1.919E-01 730 1.939E-02

395 1.144E-03 480 9.289E-02 565 4.287E-01 650 1.737E-01 735 1.648E-02

400 1.291E-03 485 8.568E-02 570 4.276E-01 655 1.527E-01 740 1.498E-02

405 2.508E-03 490 9.256E-02 575 4.317E-01 660 1.334E-01 745 1.254E-02

410 6.650E-03 495 1.134E-01 580 4.333E-01 665 1.189E-01 750 1.075E-02

415 1.667E-02 500 1.505E-01 585 4.248E-01 670 1.048E-01 755 9.654E-03

420 3.713E-02 505 1.956E-01 590 4.194E-01 675 9.043E-02 760 8.377E-03

425 7.511E-02 510 2.410E-01 595 4.085E-01 680 7.981E-02 765 7.133E-03

430 1.415E-01 515 2.870E-01 600 3.934E-01 685 6.938E-02 770 6.247E-03

435 2.393E-01 520 3.226E-01 605 3.757E-01 690 5.963E-02 775 5.565E-03

440 3.702E-01 525 3.446E-01 610 3.593E-01 695 5.233E-02 780 4.742E-03

445 5.463E-01 530 3.644E-01 615 3.324E-01 700 4.492E-02

450 6.617E-01 535 3.795E-01 620 3.121E-01 705 3.904E-02

455 5.784E-01 540 3.886E-01 625 2.870E-01 710 3.458E-02

460 3.909E-01 545 4.010E-01 630 2.600E-01 715 2.958E-02

0.0

0.2

0.4

0.6

0.8

1.0

1.2

380 440 500 560 620 680 740 800

Page 6: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 6 of 12 The NVLAP Lab Code is 200707-0.

CIE 1931 x y Chromaticity Diagram

7-Step Chromaticity Quadrangles

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

0.30

0.35

0.40

0.45

0.30 0.35 0.40 0.45 0.50 0.55

sample

7-STEP 2200K

7-STEP 2500K

7-STEP 2700K

7-STEP 3000K

7-STEP 3500K

7-STEP 4000K

7-STEP 4500K

7-STEP 5000K

7-STEP 5700K

7-STEP 6500K

Page 7: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 7 of 12 The NVLAP Lab Code is 200707-0.

[Goniophotometer System]

Total operating time for luminous intensity distribution: 1.0 hours

Test orientation: Downward

Electrical Measurement

Input Voltage (V) Frequency (Hz) Input Current (A) Power (W) Power Factor

240.08 50 0.2233 50.96 0.9506

Photometric Measurement

Luminous Flux (lm) Efficacy (lm/W) Imax (cd) S/MH (C0/180) S/MH (C90/270)

5942.66 116.61 2212 1.29 1.35

Luminous Intensity Distribution

C0/180 C45/225 C90/270 C135/315 AVG.

Beam Angle (50% Imax): 106.7 114.2 112.5 114.7 112.0

Field Angle (10% Imax): 143.4 145.5 146.2 146.0 145.3

Page 8: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 8 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data

C

0° 22.5° 45° 67.5° 90° 112.5° 135° 157.5° γ

0.0° 2201 2201 2201 2201 2201 2201 2201 2201

5.0° 2207 2203 2201 2200 2201 2201 2195 2192

10.0° 2181 2174 2176 2192 2199 2193 2184 2178

15.0° 2135 2137 2161 2178 2178 2177 2158 2141

20.0° 2073 2093 2128 2143 2157 2147 2126 2092

25.0° 2004 2029 2075 2115 2120 2105 2069 2037

30.0° 1910 1942 2004 2036 2043 2043 2006 1946

35.0° 1801 1843 1899 1923 1909 1938 1919 1849

40.0° 1661 1710 1770 1766 1750 1779 1786 1727

45.0° 1505 1561 1612 1596 1577 1602 1630 1577

50.0° 1217 1341 1418 1377 1359 1389 1420 1417

55.0° 1018 1080 1202 1172 1162 1180 1229 1123

60.0° 753 789 864 930 802 940 966 897

65.0° 478 524 583 585 582 610 692 610

70.0° 254 286 288 320 314 363 351 351

75.0° 100 109 99 120 127 130 140 152

80.0° 18 16 18 13 12 15 33 30

85.0° 11 9 7 5 5 6 8 11

90.0° 0 0 0 0 0 0 0 3

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 1 0 0 0 0 0

105.0° 1 1 1 1 1 1 1 1

110.0° 1 1 1 1 1 1 1 1

115.0° 1 1 1 1 1 1 1 1

120.0° 1 1 1 1 1 1 1 1

125.0° 1 1 1 1 1 1 1 1

130.0° 1 1 1 1 1 1 1 1

135.0° 1 1 1 1 1 1 1 1

140.0° 1 1 1 1 1 1 1 1

145.0° 2 2 2 2 2 2 2 2

150.0° 2 2 2 2 2 2 2 2

155.0° 2 2 2 2 2 2 2 2

160.0° 3 3 3 3 3 3 3 3

165.0° 2 2 2 2 2 3 3 3

170.0° 2 2 2 2 2 2 2 2

175.0° 2 2 2 2 2 2 2 2

180.0° 2 2 2 2 2 2 2 2

Page 9: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 9 of 12 The NVLAP Lab Code is 200707-0.

Luminous Intensity (cd) Distribution Data (cont.)

C

180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° γ

0.0° 2201 2201 2201 2201 2201 2201 2201 2201

5.0° 2198 2200 2202 2208 2210 2209 2208 2206

10.0° 2181 2186 2192 2201 2205 2195 2192 2184

15.0° 2148 2160 2169 2180 2180 2172 2156 2146

20.0° 2086 2102 2126 2149 2157 2144 2118 2089

25.0° 1998 2042 2077 2117 2127 2107 2055 2022

30.0° 1915 1951 2015 2049 2039 2041 1989 1925

35.0° 1803 1840 1926 1923 1902 1923 1909 1819

40.0° 1672 1723 1793 1781 1765 1774 1760 1689

45.0° 1521 1584 1620 1608 1555 1596 1612 1542

50.0° 1343 1418 1445 1373 1353 1375 1420 1342

55.0° 1051 1149 1227 1183 1167 1179 1205 1090

60.0° 785 894 990 968 801 959 899 797

65.0° 543 624 684 611 599 593 655 531

70.0° 309 354 360 370 309 325 324 300

75.0° 126 157 176 179 151 145 131 124

80.0° 21 21 37 19 15 17 28 19

85.0° 13 13 10 8 6 8 10 11

90.0° 0 0 0 0 0 0 0 0

95.0° 0 0 0 0 0 0 0 0

100.0° 0 0 0 0 0 0 0 0

105.0° 0 0 0 0 0 0 0 0

110.0° 0 0 0 0 0 0 0 0

115.0° 0 0 0 1 1 1 0 0

120.0° 1 1 1 1 1 1 1 1

125.0° 1 1 1 1 1 1 1 1

130.0° 1 1 1 1 1 1 1 1

135.0° 1 1 1 1 1 1 1 1

140.0° 1 1 1 1 1 1 1 1

145.0° 1 1 1 1 1 1 1 1

150.0° 1 1 1 1 1 1 1 1

155.0° 1 1 2 2 2 2 2 2

160.0° 2 2 2 2 2 2 2 2

165.0° 2 2 2 2 2 2 2 2

170.0° 2 2 2 2 2 2 2 2

175.0° 2 2 2 2 2 2 2 2

180.0° 2 2 2 2 2 2 2 2

Page 10: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 10 of 12 The NVLAP Lab Code is 200707-0.

Average Area Illumination Figure

Height (m) Diameter

(cm) Eavg(lx) Emax(lx)

0.5 148.26 2790.0 8845.0

1.0 296.51 697.6 2211.0

1.5 444.77 310.0 982.8

2.0 593.02 174.4 552.8

2.5 741.28 111.6 353.8

3.0 889.54 77.5 245.7

3.5 1037.79 56.9 180.5

4.0 1186.05 43.6 138.2

4.5 1334.30 34.5 109.2

5.0 1482.56 27.9 88.5

Angle: 112.0 °. Flux out: 4817.0 lm

Page 11: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 11 of 12 The NVLAP Lab Code is 200707-0.

Zonal Lumen Density Measurement

Deg Flux (lm) %

Deg Flux (lm) %

0-5 52.7 0.89 0-5 52.7 0.89

5-10 157.1 2.64 0-10 209.8 3.53

10-15 258.0 4.34 0-15 467.8 7.87

15-20 352.9 5.94 0-20 820.6 13.81

20-25 439.4 7.39 0-25 1260.1 21.20

25-30 514.3 8.66 0-30 1774.4 29.86

30-35 570.6 9.60 0-35 2345.0 39.46

35-40 605.4 10.19 0-40 2950.4 49.65

40-45 616.4 10.37 0-45 3566.8 60.02

45-50 597.8 10.06 0-50 4164.6 70.08

50-55 550.3 9.26 0-55 4714.9 79.34

55-60 472.1 7.94 0-60 5187.0 87.28

60-65 351.8 5.92 0-65 5538.8 93.20

65-70 234.1 3.94 0-70 5772.9 97.14

70-75 118.3 1.99 0-75 5891.2 99.13

75-80 36.2 0.61 0-80 5927.4 99.74

80-85 7.0 0.12 0-85 5934.5 99.86

85-90 2.7 0.05 0-90 5937.2 99.91

90-95 0.1 0.00 0-95 5937.3 99.91

95-100 0.2 0.00 0-100 5937.5 99.91

100-105 0.2 0.01 0-105 5937.7 99.92

105-110 0.3 0.00 0-110 5937.9 99.92

110-115 0.3 0.01 0-115 5938.2 99.93

115-120 0.3 0.00 0-120 5938.5 99.93

120-125 0.3 0.01 0-125 5938.8 99.94

125-130 0.4 0.00 0-130 5939.2 99.94

130-135 0.4 0.01 0-135 5939.6 99.95

135-140 0.4 0.01 0-140 5940.0 99.96

140-145 0.5 0.00 0-145 5940.5 99.96

145-150 0.5 0.01 0-150 5941.0 99.97

150-155 0.5 0.01 0-155 5941.5 99.98

155-160 0.4 0.01 0-160 5941.9 99.99

160-165 0.3 0.00 0-165 5942.2 99.99

165-170 0.2 0.01 0-170 5942.5 100.00

170-175 0.1 0.00 0-175 5942.6 100.00

175-180 0.1 0.00 0-180 5942.7 100.00

Page 12: IES LM-79-08 TEST REPORT - LED Tube, LED Floodlight, LED High Bay · PDF fileSTATEMENT: This test may not be duplicated or used in part without prior written consent from Bay Area

Bay Area Compliance Laboratories Corp. (Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian

Free Trade Zone Shenzhen, Guangdong, China

Report No. RSZ160118505-10 Page 12 of 12 The NVLAP Lab Code is 200707-0.

6. Product Photo

***********END OF REPORT***********