Energy conservation vs IEQ | HVAC.....it all starts with the napkin

Phil WilkinsonChief Executive OfficerAIRAH

Page 2: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

No longer allowed

Page 3: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Less than ideal

Page 4: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

We don’t want this

Page 5: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

We don’t want this

Page 6: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Consider maintenance at day one

Page 7: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Sustainability checklistLifecycle costsEnergy useWater useNoiseRefrigerant applicationMaintainabilityCommissionabilityReliabilityMonitoring and meteringSystem optimisation and tuning (ability)Indoor environment qualityExternal environmental impactsMaterials and embodied energiesConsumables and future accessDocumented sustainability features

Many considerations – IEQ and energy only two of them

Page 8: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Maintenance objectivesThe owners’ objectives for maintenance policy can include:• Return on investment• Asset protection and enhancement• Legal compliance• Health and safety• Building sustainability• Indoor environment quality• Risk management• Cost limitations• Marketing• Corporate image.

Only two parts to consider in the process

Page 9: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Maintainability - Design

• Simple• Reliable• Sustainable• Fit for purpose• Provide required function

System designers are best placed to develop design / maintenance philosophy

Page 10: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Access is king – do it right

Page 11: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Access is king

• Good access is essential to allow plant to be maintained easily and safely.

Page 12: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

Commissioning• Optimised system performance.• Lower operating costs.• Better indoor environment quality.• Reduced risk.• Reduced downtime.• Better system knowledge.• Better data for maintenance management.

Page 13: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

OperationEnergy Efficiency maintenance

Energy management is a continuous process• Audit• Strategy• Improvements

– optimal stop/start,– load reset on variation in outdoor air temperature,– greater use of sub metering,– air handling system rebalancing,– recalibration of controls,– dampers repaired,– reducing maximum demand,– heat reclaim,– reset cooling and heating fluid temperatures.

Page 14: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

OperationIAQ maintenance

• Maintenance contributes to IAQ• Step one – establish IAQ policy• Step two – develop IAQ management system• Step three - improvements

– Outdoor air ventilation rates– Application and maintenance of air cleaning devices– Air handling unit and duct cleanliness– Air distribution and balancing– Air analysis and assessment– Recirculation rate, air change rate– VAV terminal unit settings and operation.

Page 15: IEQ vs energy - it starts with the napkin | Healthy buildings 2012

.

Summary

•Napkin•Design•Install•Commission•Handover•Operate

...with maintenance in mind