Transcript of IDEA StatiCa Seel Connections - seminar Genk/Kortrijk nov 2016
2
IDEA STATICA FOR STRUCTURAL ENGINEERINGDevelopment team with 20 years of experience of making innovative software for structural engineers in more than 40 countries.
2
Engineering software dedicated to structural design and code-check of joints, cross sections, beams and other details.
1000+ desktoplicenses
Software resultsvalidated byuniversities
Linked to 12+CAE/CADprograms
30+ employees15+ resellers
66
STRUCTURAL DEFECTSBut the majority of defects is caused by bad design of a particular joint or other detail.
Waste of time
Waste of material
88
IDEA STATICA COMPLEMENTS WHAT YOU HAVE
Whole structure
Structuraldetails
Low resources Big resources
99
IDEA StatiCa is the first one to provide SW for joints and connections with development capacity and professionalism of CAE programs.
1313
STANDARDEasy joint
NON-STANDARDDifficult joint
Design books Advanced scientific model
Excel spreadsheet
Estimation
Avoid using the joint
1414
30 %Difficult joint
70 %Easy joint
30 %Easy joint
70 %Difficult joint
NUMBER OF JOINTS TIME SPENT
1818
DESIGN WITH IDEA STATICA CONNECTION
Stress-strain Buckling Analysis Stiffness Analysis Overall Check
19
Stress-strain Buckling analysis Stiffness analysis Overall check
19
ELECTRICITY TOWER MAST – POLAND
Huge normal force loads the group of bolts eccentrically. Bolts cannot take this.
Rearranging of bolts solved the problem.
2020
Stress-strain Buckling analysis Stiffness analysis Overall check
STEEL WAREHOUSE – GERMANY
Connection fully satisfies all stress/strain checks
But the web of the beam can collapse because of local buckling
Additional stiffener resolved this problem
21
Stress-strain Buckling analysis Stiffness analysis Overall check
21
POWER PLANT – CZECH REPUBLIC
Ovalization of CHS. Stiffness perpendicular to CHS is weaker.
All CHS are welded to one plate. Stiffness is 10x higher.
22
Stress-strain Buckling analysis Stiffness analysis Overall check
22
HEATHROW AIRPORT – UK Connection was not designable with the suggested prescribed EC3 requirements and a more generic analysis approach had to be adopted.
24
TESTIMONIALFRISOMAT
24
“IDEA Connect werkt vlot en snel. Er is geen gebruiksvriendelijker alternatief voorhanden dat toelaat FEM met CBM te combineren.IDEA is gewoon degelijk en goed.”
Prof. Dr. Ir. Luc SchueremansEngineering Manager
27
COMPONENT BASED FINITE ELEMENT MODEL (CBFEM)The weak point of standard Component method Design guides is that the topology is limited.
27
Component Model Bolted Joint CBFEM model
3030
VERIFICATION – COMPLEX TOPOLOGIESTailor-made design models created in various software.Live testing. All studies published.Two university teams spent over 3 years on this.
32
There is sophisticated method inside. It was verified and transformed into a tool how to create joints.
32
34
TESTIMONIALOOSTINGH STAALBOUW KATWIJK
34
Alexander van Beelen
“Geeft beter en ook nieuw inzicht in de krachtswerking in verbindingen. Rapportage mag nog watverbeterd worden.”
3636
BIM INTERFACE – CAD PROGRAMSTekla Structures and Advance Steel.
Node Selection in AS Input of Load Effects Check EN / AISC
3737
BIM INTERFACE – FEA PROGRAMSRobot, SAP 2000, SCIA Engineer, RFEM, AxisVM etc. (Buildsoft Diamonds coming)
Node Selection in RSA Design of Connection Check EN / AISC
3838
IDEA StatiCa would not build such strong links without having strong relationships with the key players in our industry.
43
TESTIMONIALSTAALBOUWKUNDIG ADVIESBURO VAN ODENHOVEN
43
Marcel van Odenhoven
“Idea Connection is een zeer behulpzaam pakket voor het modelleren van een breed scala van verbindingen in staalconstructies. Het modelleren en interpreteren van de resultaten vraagt inzicht in de krachtswerking binnen een knoop en gaat gelijk op met de complexiteit van de verbinding.”
Tool needs to… Allow efficient workflows through
interoperability Be simple to learn and use Be fully supported by codes and validated
theory Be used for concept through to detailed
design
Arup use of IDEA StatiCa Connection
TeklaDrawing Model
RhinoTransition Model
ExcelLoad Input
D3 PlotStress checks
Excel/VBWeld checks
ANSAMeshing
Nastran Analysis
GSAGlobal Analysis
Modelling, Analysis, Design, Fabrication
5959
REPORTINGWe support Eurocode and AISC.Various sets of material types, cross-sections, bolts, etc.Different types of reports.Schemes of drawings.
6060
OUTPUT REPORTThree types of output reports – one line, 1 page and detailed.
All checks according to Eurocode or AISC displayed and referenced.
61
CUSTOMER PROJECTCEPS – Electricity Tower Masts
61
Special request for manufacturing operations.Developed in 8 weeks.We also provided consultancy
62
CASE STUDYCEPS INVEST
62
Cenek LaubHead of engineering department
“Maintaining and developing electricity network in the Czech Republic is full of challenging tasks. With IDEA StatiCa Connection, joint design got much easier and faster for us.”
6363