Ict Data Logger Report
-
Upload
nhr-meedah-rohani -
Category
Documents
-
view
216 -
download
0
Transcript of Ict Data Logger Report
-
8/3/2019 Ict Data Logger Report
1/5
SSI 3013
INFORMATION AND TECHNOLOGY IN SCIENCE
GROUP MEMBERS :
NOORIDAYU BT MOHAMED D20091035077
HASNOR IZZATI BT CHE RAZALI D20091035119
NOR SHARLIDA BT MOHAMAD JALAILUDIN D20091035098
NORHAMIDAH BT ROHANI D20091036643
MOHAMAD ARIF BIN NASARUDDIN D20091035123
DATA LOGGER REPORT
EXPERIMENT ON REGULATION OF HUMAN BODY
TEMPERATURELOSS OF HEAT THROUGH SWEAT
PRODUCTION : HEAT LOSS MEASURED AT FINGERTIP.
-
8/3/2019 Ict Data Logger Report
2/5
Title :
Regulation of human body temperatureLoss of heat through sweat production : Heat loss
measured at fingertips
Equipment Setup
1. The Discovery is connected to the serial port of the computer2. The Discovery was turned on3. The temperature is connected to the 1/0 port and 1/0 2 port of the Discovery4. The humidity sensor is connected to 1/0 3 of the discovery5. The Discovery is set up
a. Input 1: Temperature (-10500)b. Input 3: Humidityc. Rate: 1/secd. Sample: 2000
Experiment Procedure :
1) Attach a temperature sensor to the fingers of your right arm, as demonstrated infigure.
2) Start the discovery either from the discovery panel or from discover the IT software :click the run button on the left tool bar.
3) Follow temperature changes in your fingertip, register on your computer monitor, tillit stabilizes about 5 minutes.
4) Cover the hand holding the temperature sensor, with a plastic bag.5) Place inside the bag a humidity sensor and an additional temperature sensor.6) Tie the bag covering your hand, to prevent air flow into and out of the bag.7) Follow changes in humidity and temperature inside the bag, for about 10 minutes.8) Remove the plastic bag from your hand. Follow changes in the humidity and
temperature inside the plastic as well as the temperature of your fingertip, for
additional 5 minutes.
-
8/3/2019 Ict Data Logger Report
3/5
Result :
Data table
Graph of temperature and humidity against time
-
8/3/2019 Ict Data Logger Report
4/5
Discussion
Experiment conducted to study the relationship between body temperature and
humidity. Based on the data and the graph obtained, we can see that for the first 400 seconds,
temperature is higher than humidity. This is the time when hand is still not covered with
plastic bag, so the temperature follows the normal body temperature. After the hand is
covered with plastic bag, the temperature and the humidity are both rises. When high
temperatures are combined with high humidity, it feels very warm.
The temperature increase because the air is trapped inside the plastic bag causing the
environment now is warm in the plastic bag. High temperature in the plastic bag causes
humidity to increase. The body senses changes in the environment and responds by makingchanges in functions. We know that the hypothalamus in the brain can act as a thermostat and
control the bodys functioning to regulate temperature to keep us from overheating or getting
too cold. The hypothalamus causes changes in the size of blood vessels in the skin, which
then has a direct impact on the amount of heat lost or retained by the body. Then, our heart
rate and pulse rate increase and our hand start to sweat. Sweating is the process to cool down
our body.
The last 5 minutes, the hand is uncovered. We can see from the graph, temperature is
now rising while humidity is decreasing. At this stage, our body temperature is returned to
normal. When there is no sweat produced, humidity is low.
Conclusion
Humidity decrease when temperature increases.
-
8/3/2019 Ict Data Logger Report
5/5
ADVANTAGES OF DATA LOGGER
1) Advantages for Users: Ease of use and productivity
PDF report is instantly ready to be e-mailed to Sender Easy handling, no specific procedures needed, no wrong manipulations possible Clearly structured display for immediate visibility of any temperature deviations
during transportation
Shortened workflow thanks to the unique feature of the automatically generatedanalysis and compound report
2) Advantages for Supply Chain Managers: Productivity and Flexibility
Quick and easy availability of supply chain history Straightforward transmission of complete reports (data and graphics) thanks to PDF/A
format
Problems within the cold chain can rapidly be illustrated Detailed evaluation of raw data possible with elproLOG Analyze Evaluation Software No specific training required
3) Advantages for Quality Managers: Assured quality
5 programmable alarm ranges according to PDA Technical Report No 39 (Cold ChainGuidance for Medical Products: Maintaining the Quality of Temperature-sensitive
Medicinal Products through the Transportation Environment)
PDF/A is an approved ISO standard Helps to be compliant with the provision of FDA 21 CFR 11 Swiss quality productLife time warranty
4) Advantages for Purchase Managers: Cost efficiency
Excellent price/performance ratio No cost for worldwide software training, SW validation, SW support, software
upgrading
No cost for user training5) Advantages for IT Managers: Reliability and seamless integration
No specific evaluation software necessary (AdobeReader) No additional hardware required (USB port of PC) No additional infrastructure cost for software validation, upgrade policy and end user
support
No user training necessary6) Advantages for Financial Directors: Cost savings
Cost effective solution for total cold chain monitoring Safe investment thanks to proven technology, ELPROs compatibility strategy and the
long-term experience of elpro in providing professional data logging solutions