Ici final project
Transcript of Ici final project
![Page 1: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/1.jpg)
FNBE April 2014
Introduction to Construction Industry
Final Project Report
Name: Chong Yu Xuan (0317950)
Kong Zhen Chung (0319528)
Lecturer: Pn. Hasmanira Mokhtar
![Page 2: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/2.jpg)
Content
1.) Introduction
2.) Suggestion and Proposal
3.) Rationale and Benefits
4.) Site analysis and observation
5.) Sketch plan
6.) Introduction to the site
7.) Site Plan
8.) Authority Procedures
9.) Costing
![Page 3: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/3.jpg)
Introduction
In a group work of 2 people Chong Yu Xuan and Kong Zhen Chung. We are
required to find a specific land within Taylor Lakeside Campus to initiate a small
construction project. Size of the chosen land should not be more then
30mx30m.We choose to propose a food and beverage area idea for our site. As a
group , we are required to produce a project brief on the construction.
![Page 4: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/4.jpg)
Suggestion and proposal
For this project , we decided to propose a 24/7 food and beverage (dining area) that
provide full meals at our site. The dining area will have a restaurant that sells
economical and also healthy foods.
![Page 5: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/5.jpg)
Rationale and Benefits
Rationale
According to our survey and research many students usually does their
assignments till late night in the studios and classrooms of block E. The only eatery
available till late night are “Mamak” and seven eleven for snacks. These eatery are
oily and unhealthy which will cause health problems after overconsumption.
Furthermore, the food and beverages in Taylor’s Lakeside Campus are overpriced
and unsuitable for student ,all the more reason for an economical eatery.
![Page 6: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/6.jpg)
Benefits
This dining area in our site can bring much benefits to Taylor’s community
including:
1. Students around Block C/D/E do not need to walk long distance to the
commercial block to have a meal.
2. Enjoy beautiful scenery around that area.
3. Make use of the empty space.
4. Creating more business in the campus and improve social issues.
5. Economical food help students with financial burdens
6. Add choices to food variety in University compound
![Page 7: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/7.jpg)
Site Analysis
The site we had chosen is on the roof garden at level 2, right at the end of Block E.
Our site is approximately 27m x 15m. It is a public space roof terrace and an open
space with only a partial roof by the side. It has railing of 1.2 meters high along the
side of the site. There is a roof of 3 meters extending out from the right railing of
the site. To the south, there is a car park area and a sport court. To the west, there is
a view of the opposite roof terrace of the same level. To the east, there is a view of
large trees and residential area. There is a view of the Taylor’s lake on the south-
west
The site is located at Taylor’s lakeside campus, Block E, Level 2, balcony.
![Page 8: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/8.jpg)
Key Plan
![Page 9: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/9.jpg)
Location Plan
![Page 10: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/10.jpg)
Floor Plan
![Page 11: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/11.jpg)
In our site, it is free from air pollution, this is because our site is surrounded by
the car park spaces which is away from the roads. Our site also located at higher
level than the car park spaces. The wind strength in our site is average because our
site is attached to the block E building. Our site is located at block E, level 2. The
temperature in our site is normal because there are slow wind blowing toward our
site and our site is avoid from sun except in the afternoon half of our site will
explored by the sunlight. The only sound pollution faced in our site are the
condenser of the air conditional attached to the wall of buildings beside our site.
In front of the balcony, it’s a car park and
this is the view from our site looking
towards the car park.
The railing around the perimeter of the
balcony. It’s a 1m tall railing around the
balcony and it’s lifted by 15cm concrete step.
Sun Orientation
The sunlight will only reach the balcony
when afternoon 12pm to 2pm. Most area of
the site is shaded.
![Page 12: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/12.jpg)
Full Site view from the entrance, as you can
see it is empty and unused
Block E, view from balcony.
Human Traffic
The entrance is wide, no traffic congestion
as this place is not used for anything
![Page 13: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/13.jpg)
Proposed Site Introduction
After complete this project, our site had finally become a food and beverage area. It consists a
kitchen at the corner of our site. There will also be a bar beside the kitchen. The purpose that we
build a bar in it is to serve different types of drinks for the customers.
Rationale:
Students can dine at this area without walking very long distance to the
commercial block.
![Page 14: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/14.jpg)
Zoning
Restaurant
Dine area
Leisure and sightseeing area
![Page 15: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/15.jpg)
Site Plan
Door Benches Outdoor umbrella Table Potted plant
Kitchen Bar
![Page 16: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/16.jpg)
![Page 17: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/17.jpg)
Authority Procedure
Development order
Submit and obtain Dev elopment Approv al through OSC
Builders can now apply for construction permits through OSC 1Submission (single entry). OSC will then refer the submissions t o
the Planning Department, Building Department, Engineering Department, Fire Department, Sewerage Agency, Water Agency and
the Telecommunication Operators.
OSC will issue the development approval (Planning aprrovals, Building approvals, Engineering approvals, Fire safety plan
endorsements, water approvals, sewerage works approvals and Telecommunications approvals) to the builder. While all forms can
be obtained online at jprb.dbkl.gov.my/Pentadbir/MuatTurunBorangOSC/MTBorang11.asp, the fi ling has stil l to be done in person
at the OSC.
Builder will submit and obtain approval through OSC for the following documents:
• Planning plan
• Building plan
• Engineering plan (earthwork, road & drainage plan, road excavation permit & street l ighting plan)
• Landscape plan
• Water supply plan
• Sewerage plan
• Infrastructure communication plan
• Fire safety plan
Estimated Processing Costs
1. Planning plan = MYR 500.00
2. Building plan= MYR 1,300.
3. Engineering plan = MYR 100.00
![Page 18: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/18.jpg)
Development order
4. Water supply plan = MYR 1,000.00
1. Submission to Local Authority through OSC
2. Obtain Development Order (DO) from Planning Department
3. Obtain Water Approval
4. Obtain Sewerage Approval
5. Obtain Fire Safety (Arch) Comment
6. Obtain Earthwork Approval
7. Obtain Road and Drainage Approval
8. Obtain Landscape Approval
9. Obtain Street Lighting Approval
10. Obtain MSMA and SPAH Approvals
11. Obtain Building Plan Approval
12. Obtain Fire Safety (M&E) Approval
Agency: Kuala Lumpur City Hall’s One Stop Centre (OSC)
Submit pre-construction notifications to OSC
Under OSC 1Submission, all notifications are submitted via OSC. OSC will then distribute notifications to the relevant agencies
such as:
• Building Department (B Form - notification to start building work)
• Engineering Department (B Form - notification to start earthwork)
• Sewerage Certifying Agency (IWK) (PDC 6 Form - notification to start sewerage work)
Agency: Kuala Lumpur City Hall’s One Stop Centre (OSC)
Request final utilities inspections through OSC
Under OSC 1Submission, the builder has to request for inspections via OSC. OSC will arrange and coordinate inspections and
connections schedule with relevant agencies
1. TELCO connection = MYR495.00
2. Water connection = MYR 30.00
3. Fire safety inspection = MYR 111.00
Agency: Kuala Lumpur City Hall’s One Stop Centre (OSC)
Receiv e Road and Drainage Final Inspection
Once the road and drainage works has been completed, the builder will request the Road and Drainage clearance letter from the
Engineering Department of CHKL. The builder has to submit a construction report notification and by signing form G 17, the
Engineer certifies that all works were carried out according to regulations. Form G17 will be fi led along with Form F (Certif icate of
Completion and Compliance (CCC) via OSC to the Engineering Department.
Agency: Sewerage Certifying Agency (IWK)
Obtain Road and Drainage Clearance Letter
![Page 19: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/19.jpg)
Development order
A date for the inspection will be set-up prior to the issuance of clearance letter for the road and drainage work
Agency: Sewerage Certifying Agency (IWK)
Receiv e Sewage Final Inspection
The Sewerage Certifying Agency (IWK) will carry out an inspection of the sewerage system and issue to the builder a clearance
letter for sewerage.
Agency: Sewerage Certifying Agency (IWK)
Obtain Sewage Clearance Letter
Once the inspection has been carried out, a clearance letter is issued to the Builder. This clearance letter will allow the E ngineer to
issue the Certificate of Completion and compliance (CCC).
Agency: Sewerage Certifying Agency (IWK)
Receiv e Fire Safety Final Inspection
Fire and Rescue Department will carry out fire safety inspection
Agency: Fire and Rescue Department
Obtain Fire Safety Final Letter
Fire and Rescue Department will issue to the builder the clearance letter for fire safety
Agency: Fire Department
Receiv e Water Inspection
Water Authority SYABAS will conduct an onsite inspection of the works and make the connection to the public pipe.
Agency: Water Authority SYABAS
Submit Water Test and Commissioning (T&C) Report
Water Authority SYABAS will conduct an onsite inspection of the works and make the connection to the public pipe.
Agency: Water Authority SYABAS
Obtain Water Clearance Letter
The Water Authority SYABAS will issue a clearance letter to the builder and insta ll the water meter at the same time for water
connection.
Agency: Water Authority SYABAS
Builder’s Principal Submitting Person files the Certificate of Completion and compliance (CCC)
The Builder’s Principal Submitting Person (professional|architect) will issue Certificate of Completion and compliance (Form F -
CCC) to the Builder/Owner and 2 copies of the CCC will be fi led at the OSC for the Building Department (JRBB) and the Board o f
Architects/Engineers (LAM/LJM).
Agency: Building Department and Board of Architect via OSC.
Obtain Water Connection
Agency: Water Authority SYABAS
Obtain Telco Connection
![Page 20: Ici final project](https://reader033.fdocuments.us/reader033/viewer/2022042816/559575401a28ab575c8b4791/html5/thumbnails/20.jpg)
Costing
Description Single unit price Quantity Prices
Restaurant Restaurant RM20000 1 RM20000
Table RM120 40 RM480
Chairs RM25 200 RM5000 Kitchen utensils - - RM8000
Lighting RM30 10 RM300 Outdoor
Potted plant RM25 30 RM750 Advertisement board RM1300 2 RM2600
Outdoor umbrella RM150 10 RM1500
Total RM38630