IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS,...

74
© 2010 IBM Corporation 1 IBM ® Storwize ® V7000 Инновационная и эффективная система хранения Start small Think BIG Doronchenkov Grigory STG Storage Technical Sales Specialist [email protected]

Transcript of IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS,...

Page 1: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation © 2010 IBM Corporation 1

IBM® Storwize® V7000

Инновационная и эффективная система хранения

Start small Think BIG

Doronchenkov Grigory

STG Storage Technical Sales Specialist

[email protected]

Page 2: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

IBM Storwize V7000 Основные принципы

2

Виртуализация – эффективность и консолидация

Модульная расширяемость, независимое

расширение как по производительности, так и по

объему– позволяет начать с малого и расти без

изменений в платформах

Интегрированные программные возможности и

управление в одном окне

Программное обеспечение класса Enterprise,

простое управление позволяющее быстро

работать в меняющихся и сложных окружениях

Page 3: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 3

Виртуализация - это логическое предоставление ресурсов не

связанное с их физическими характеристиками:

-Создание множества виртуальных ресурсов из одного физического

-Динамическое изменение и увеличение инфраструктуры

Экономия до $50,000 на электроэнергии на power 1,000TBs емкости

До 60% на стоимости миграции

До 300% увеличение утилизации

Серверная виртуализация

До 30-70% экономия на TCO

Виртуализация СХД

До 25% требуемого пространства

Экономия до 33-50% на серверной

33-70% расходы на оборудование.

До 50% на поддержку.

До 33% гарантийное обслуживание.

Польза от виртуализации:

Page 4: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 4

IBM Disk Portfolio 4Q2010

Block File

Enterprise

DS8000 For clients requiring:

Advanced disaster recovery with

3-way mirroring and System z

GDPS support

Continuous availability, no

downtime for upgrades

Best-in-class response time for

OLTP or transaction workloads,

flash optimization

Single system capacity scalable

to the PB range

XIV For clients requiring:

Virtually unlimited snapshots

High utilization with automated

performance (“hot spot”)

management

Advanced self-healing

architecture

Breakthrough ease of use and

management

SONAS For clients requiring:

Massive I/O, backup, or restores

Consolidation, or scale large

numbers of clusters

N series For clients requiring:

NAS storage

Simple two-site high availability

Midrange

DS5000 For clients requiring:

Good cost/performance, general-

purpose storage

Need to add capacity to existing

configuration

10s of TB of capacity

Storwize V7000 For clients requiring:

10s of TB of rack-mounted

storage with sophisticated

software functions

Breakthrough ease of use and

management

Non-disruptive migration from, or

virtualization of, existing disk

Entry DS3000 For clients requiring:

SMBs or branch office locations; cost sensitive; start at as small as

100s GB, up to low TB capacity

Storage Optimizers SVC, Easy Tier, ProtecTIER, Information Archive, Real-time Compression Appliances For clients requiring optimization of storage costs:

Storage technologies that add function, performance, ease of use, or efficiency to new or existing storage

Optimized for ‘open systems’ Optimized for z/OS and IBM i

Page 5: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 5

Ценность виртуализации систем хранения

Enterprise Strategy Group(ESG) утверждает, что компании

внедрившие виртуализацию систем хранения в среднем в год

экономят:

– 24% на оборудовании

– 16% на программном обеспечении

– 19% на администрировании

При бюджете в $1 миллион, тратя $500,000 на оборудование,

$200,000 на программное обеспечение и $300,000 на

обслуживание.

Source: http://searchstorage.techtarget.com/tip/1,289483,sid5_gci1122304,00.html

Ежегодная экономия может быть $209,000

Page 6: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation

Storwize V7000 – Виртуализированый массив

Storwize V7000 использует физические диски (managed disks) и собирает

их в один или несколько пулов хранения (storage pools).

Пул хранения предоставляет емкость для создания томов.

6

Тома(Volumes)

Пул хранения(Storage Pool)

Диски (Managed Disks - MDisks)

Page 7: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation

Storwize V7000 – преимущества виртуализации

Любой созданный Том

располагается на всех дисках

пула хранения.

Любой том использует

производительность всех

физических дисков пула

7

A2

A6

B1

B5

A3

A7

B2

B6

A4

A8

B3

B7

A1

A5

A9

B4

B8

A1 A2 A3 A4 A5 A6 A7 A8

B1 B2 B3 B4 B5 B6 B7 B8

A9 Volume A

Volume B

Volumes

Managed Disks

Page 8: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 8

2U

Proven IBM Software functionalities

Easy Tier (dynamic HDD/SSD management)

RAID 0, 1, 5, 6, 10

Storage Virtualization (local and external disks)

Non-disruptive Data Migration

Global & Metro Mirror

FlashCopy up to 256 copies of each volume

Thin Provisioning

New Advanced Software functions

New GUI (easy-to-use, web based)

RAID & enclosure RAS services and diagnostics

Miscellaneous scalability improvements

Additional Host, Controller and ISV interoperability

Integration with IBM Systems Director

Enhancements to TPC, FCM and TSM support

Модульная конструкция 2U

Software inherited from prior Offerings plus Enhancements

IBM Storwize V7000 – богатство функционала

Page 9: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation

Самая мощная СХД в классе Mid-Range

SSD и IBM Easy Tier повышают производительность приложений

Поддержка SAS дисков

– SSD, SAS, и Near-Line SAS

– Диски: 24 2.5” или 12 - 3.5” (or intermixed)

– Восемь 8Gb FC и четыре 1Gb iSCSI порта

Технология виртуализации

SAS 2.0 для подключения дисков

Объем без Сложности Легко настраивать и обслуживать

Интуитивный графический интерфейс

Модульная - Начните с малого и легко наращивайте объем в зависимости от требований

-до 9 полок расширения

Мощность Энтерпрайз по цене Mid-Range Контроллеры и полки для стандартного 19” шкафа

9

2U (12 x 3.5” Диски)

2U (24 x 2.5” Диски)

IBM Storwize V7000 - Эффективность

Page 10: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 10

Storwize V7000 Cluster

Clustered Systems

Scale-out

Scale

-up

• Увеличение емкости и пропускной способности в ДВА раза

• Балансировка нагрузки между

большим количеством контроллеров

• Апгрейд текущих систем • Управление системой как единым

целым

Максимальная конфигурация

Кол-во Серверов: (FC):512

Кол-во Серверов: (iSCSI):128

Макс Объем: 720TB

Кэш память: 32GB

FC ports: 16x8Gb

Ethernet ports: 8x1Gb или 8x10Gb

Кол-во дисков: 240 LFF или 480 SFF

Тип дисков: SSD, SAS, NL-SAS

Page 11: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation

IBM Storwize V7000 - Эффективность

11

Start small Одна 12 или 24 дисковая контроллерная полка

Scale Up Легко расширяется до 9 полок

12 и 24 дисковые полки могут

одновременно использоваться в

системе

20 U = 1 M

Gro

w B

ig

Page 12: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 12

SSD и технология IBM Easy Tier повышают производительность приложений

Поддержка SAS дисков

– SSD, SAS, и Near-Line SAS

– Диски: 24 - 2.5” или 12 - 3.5” (or intermixed)

– Восемь 8Gb FC и четыре 1Gb/10Gb iSCSI порта

– Четыре порта Ethernet 1Gb и 10Gb для файлового доступа

– 16GB кэш памяти

– RAID 0,1,5,6,10

Технология виртуализации

SAS 2.0 для подключения дисков

Объем без Сложности Легко настраивать и обслуживать

Интуитивный графический интерфейс

Модульная - Начните с малого и легко наращивайте объем в зависимости от требований

-до 9 полок расширения, до 240 дисков или 20 полок и 480 дисков в кластерной конфигурации

Мощность Энтерпрайз по цене Mid-Range

Контроллеры и полки для стандартного 19” шкафа

IBM Storwize V7000 Unified - Эффективность

Отличная производительность и вдвое меньший размер в

сравнении с другими СХД в классе Mid Range

V7000 Unified

V7000 Unified

Page 13: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

13

Storwize V7000 Unified – Файловый модуль

x3650M3

Форм-фактор:

2U

Процессор:

Шестиядерный Intel® Xeon® X5650

2.66GHz, 8MB L2 cache, 80W

Память:

72GB DDR3 RAM

Диски(для собственных нужд):

2 * 500GB 10K SAS

RAID 1

Сетевые интерфейсы:

4 порта 1 GbE

2 для данных

2 для управляющей сети

Два порта 10GbE для данных

Два порта 8Gbps Fibre Channel для

соединения с основным(блочным) модулем

Вид спереди

Вид сзади

HDDs

13

Page 14: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 14

Почему это важно?

Конвергенция различных типов нагрузок на Storwize V7000 Unified для большей эффективности

Консолидация различных файловых ресурсов(серверов) для лучшего управления

Апгрейд текущих систем Storwize V7000 (доступность с 1 квартала 2012)

Storwize V7000 Unified Файловый доступ

Что это? Унификация системы хранения для

одновременного предоставления блочного и файлового доступа

Поддержка файловых протоколов NFS/CIFS/FTP/HTTPS/SCP

Локальная и удаленная репликация файлов

Page 15: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Приложения по типу доступа

Тип данных который преимущественно использует файловый

доступ:

– Rich Media (pictures, videos, seismic data, medical imaging, etc.)

– VOD, AOD, IPTV

– Analytics (SAS grid)

– ECM (Enterprise Content Management – e.g., web stores)

– Research Data Sets

– User files (documents, etc.)

– PLM/PDM (Product Lifecycle/Data Management)

– Virtualized Environments (VMware client-driven deployment)

Тип данных который преимущественно использует блочный

доступ:

– RDBMS (Oracle, SQL Server, DB2)

– Analytics (stream processing)

– OLTP

– Metadata Layers (component of content management)

– Email (MS Exchange, Notes)

– Virtualization Stacks (VMware: VDI, VMDK implementations; HyperV; Citrix Xen)

Page 16: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation 17 17

Узнайте больше: www.ibm.com/storage/v7000

Для организаций которым нужна Эффективность в хранении их данных… Виртуализация хранения с Thin Provisioning повышает утилизацию на

30%

Экономия пространства при использовании 2.5 дюймовых дисков

SSD технология снижает требования к энергозатратам и охлаждению, в

сравнении с традиционными дисками(HDD)

Миграция данных в онлайн режиме без влияния на пользователей.

Обслуживание по расписанию и миграция в назначенное время

Функционал установлен и доступен сразу.

Page 17: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation 18 18

Узнайте больше: www.ibm.com/storage/v7000

Для организвций которым нужна Управляемость… Управление и настройка СХД за минуты, используя предустановленные

шаблоны.

Автоматическая технология миграции данных - IBM Easy Tier позволяет

увеличить производительность на 200%, мигрируя “горячие” участки на

SSD диски

Управление многими СХД через один интерфейс и меньшим количеством

специалистов.

Page 18: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation 19 19

Узнайте больше: www.ibm.com/storage/v7000

Для организаций которым нужна производительность…

.

Анализ производительности и отчетность упрощают идентификацию

проблем с производительностью.

Виртуализация СХД позволяет решать проблемы с производительностью

без вмешательства администратора(персонала).

Масштабируемость позволяет легко расширять систему как с помощью

внутренних дисков так и за счет внешних например: IBM, EMC, HP, HDS и

др.

Page 19: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 20

Система занимает и использует дисковое пространство когда данные записываются

– Сильно снижает требуемый объем физического пространства

Приложения растут динамически, потребляя только объем который они используют

Доступно в базовой конфигурации.

Бизнес проблема :

Обычные тома, резервируют все пространство, даже если в этом нет потребности

Решение: Технология Thin Provisioning

Правильное распределение дискового объема поможет в будущем

снизить затраты на СХД до 20 %

Reduces manual effort

Просто администрировать

Снижает потребление электроэнергии и тепловыделение, а также

требуемое место в серверной

Преимущества: Thin provisioning – разумный подход к использованию емкости СХД

Много томов в Windows, Linux, и UNIX

окружении имеют огромное

зарезервированное но не занятое

пространство, которое обычно нельзя

вернуть без переконфигурации

Page 20: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 21

Бизнес проблема:

SSD диски дороги в сравнении с

традиционными дисками (HDD)

Без специальных инструментов, не

эффективное использование

Администраторы тратят много времени на

мониторинг и управление различными

уровнями хранения

Не эффективное использование очень дорогих ресурсов трудно оправдать

Решение:

Функционал перемещения данных для

экономически эффективного использования

SSD -Автоматическая миграция областей тома на

правильный уровень хранения

-Миграция целых томов в онлайн режиме

Новый инструмент - Storage Tier Advisor

предоставляет информацию о текущих

нагрузках

IBM Easy Tier

Оптимальное использование SSD – улучшает производительность и позволяет избежать ненужных

расходов

Снижает административные издержки

Настройка за минуты

Полная Автоматизация

Преимущества : Easy Tier is for Smarter Storage solutions

Page 21: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 22

Easy Tier

22

Что это такое

► Функционал который автоматически и динамически улучшает

утилизацию ресурсов хранения, мигрируя «горячие» участки

данных на высокопроизводительные ресурсы.(например SSD

диски).

Почему это выгодно

► SSD диски пока еще очень дороги и становиться

рентабельными когда полностью используются.

► Динамическое передвижение самых активных данных на

самые производительные ресурсы располагает их в

соответствии с текущими потребностями организации.

Hot-spots due to poor data

layout. Optimized performance and

throughput.

Automatic

Relocation

SSDs HDDs SSDs HDDs

Page 22: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 23

Easy Tier – как это работает

23

Magnetic Disk SSD

DPA IOM DMP DM

Data Placement Advisor распознает

увеличенную нагрузку и передает

информацию о ней Data Migration Planner

Data Migration Planner анализирует

информацию и передает рекомендации

Data Migrator на основе физических

характеристик ресурсов хранения.

Data Migrator подтверждает и планирует и

осуществляет миграцию данных без

влияния на работу приложения.

При появлении «горячих» областей на

обычном диске из-за частого или

постоянного обращения приложения к ним,

I/O Monitor записывает статистику и

отправляет к Data Placement Advisor

Storwize V7000

Dom

ino

DB

2

Exch

an

ge

Volume

EasyTier Code

Page 23: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 24

Easy Tier – Автоматическое перемещение данных

24

Volumes

created in hybrid pool

Hybrid Storage Pool

MDisk from SSD Array

MDisks from HDD Arrays

Extent

Virtualization

Hot Extents

Migrate Up

Cold Extents

Migrate Down

Volume

Page 24: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Поддерживаемые окружения

25

8Gbps SAN fabric

HP MA, EMA MSA, EVA, XP, P9500

Hitachi Lightning Thunder TagmaStore AMS, WMS, USP, USP-V VSP

EMC CLARiiON

CX4,

Symmetrix,

DMX, VMAX,

VNX, VNXe

Microsoft

Windows

Hyper-V

IBM Power7

IBM AIX

IBM i 6.1

(VIOS)

Sun

Solaris

8/9/10

HP-UX 11i

Tru64

OpenVMS

Citrix Xen

Server

IBM

BladeCenter

SAN Continuous Copy

Metro/Global Mirror

Multiple Cluster Mirror

VMware

ESX 3.5,

vSphere 4.1

Point-in-time Copy Full volume, Copy on write 256 targets, Incremental, Cascaded, Reverse, Space-Efficient, FlashCopy Mgr

Novell

NetWare

OES2

Sun StorageTek

StorEdge

IBM

DS DS3000, DS4000

DS5000, DS6000

DS8000, DS8800

1024

Hosts

IBM N series

NetApp FAS

XioTech Emprise

SGI IRIX

IBM TS7650G

ProtecTIER

Gateway

Fujitsu

Eternus

NexSAN SATABeast

NEC iStorage

Bull Storeway

Thin Provisioned Volumes

Virtual Disk Mirroring

Apple

Mac OS

IBM

XIV DCS9XXX

IBM

z/VSE

z/VM

z/Linux

RAID 0, 1, 5, 6, 10

iSCSI 1Gb or 10Gb

Compellent 5.2.3

Easy Tier

Storwize

V7000

Storwize

V7000

up to 9 exp.

2.5” drives 300GB 10k SAS

450GB 10k SAS

600GB 10k SAS

146GB 15k SAS

300GB SSD

(E-MLC)

3.5” drives

2TB 7,200 RPM

Nearline SAS

Clustered Systems

Linux

(Intel/Power/z)

RHEL 4/5

SUSE 9/10/11

Page 25: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Easy Tier – Как начать использовать

: Задействовать функционал и снять статистику

Администратор получает статистику и решает какие тома выиграют от внедрения SSD дисков

Администратор добавляет SSD и технология Easy Tier автоматически начинает оптимизировать нагрузку

27

Page 26: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 28

Миграция и высокая доступность

Эффективное управление

апгрейдами и сменами

платформ, с помощью

перемещения данных на

Storwize V7000.

Миграция

Legacy

Network

Application

server

Локальное зеркало

Для высочайшей доступности приложений,

синхронное зеркалирование данных

Прозрачное

перемещение

данных

Page 27: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 29

Технология FlashCopy

Up to

256

targets

Source

vdisk

FlashCopy

relationships

Бизнес проблема : Решение:

Customer Преимущества:

Быстрые и эффективные копии для резервного

копирования , тестирования и анализа данных

Репликация на уровне тома

Копии практически мгновенно доступны для

использования, 256 копий с одного источника

Технология “copy on write”

Источник и копия могут быть на как на

внутренних так и на внешних дисках

Защита от потери данных

Минимизирует влияние процесса резервного копирования на

приложения

Space-Efficient FlashCopy – занимает только используемый

объем

Уникальная возможность делать копии поврежденный данных

для анализа

Защита от потери локальных данных и окно резервного копирования

Создание копий данных на ходу не всегда

возможно при остановке приложений

Стандартные методы копирования не могут

создавать копии когда источник и копия на

разных дисковых системах

Лучшая доступность данных.

Page 28: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Flash Copy

30

Up to 256

FlashCopy

Доступность

Создавайте снимки томов для резервного копирования и тестирования

Эффективней используйте пространство с space-efficient (thin provisioned) снимками.

Сократите место занимаемое снимками

Интеграция снимков для приложений

Сократите окно резервного копирования

Создавайте клоны томов приложений для тестирования

FlashCopy Manager

Up to 256

Page 29: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 32

Удаленная репликация

Metro and Global Mirror

Потеря критически важных данных из-за

катастрофы

Бизнес проблема : Решение:

Customer Преимущества:

Гарантированная непрерывность бизнеса

Metro and Global Mirror единая лицензия

Локальные и удаленные тома могут быть на разных дисковых системах

Защита от потери данных

Удаленные копии, локальное управление

Поддержка двух копий данных между двумя

удаленными площадками

Синхронная репликация: 300 км между

площадками

Асинхронная репликация: 8000 км между

площадками

Page 30: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 33

Интерфейс управления

Page 31: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Storwize V7000 Unified Initial Setup

>>>

IBM

Confid

ential

until

Oct.

12,

2011

<<<

Page 32: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation

35 35

Простой графический интерфейс

Множество предустановок , которые облегчают настройку

Интегрируется с TPC и IBM Systems Director: настройка от сервера до СХД

Мастера настроек легко проведут по каждому этапу

Web интерфейс: доступ с любой платформы

Интуитивное оформление

Возможен экспертный режим с командной строкой

Page 33: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 36

Интуитивный графический интерфейс

Visual task flow

guidance

Integrated video

instruction

System status

always available

System

recommendations

Link to more

information if needed

Page 34: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 37

Конфигурирование пространства Create Storage Pool (auto-config )

Создание томов

Page 35: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 38

Создание Хостов

Присоединение томов

Конфигурирование пространства

Page 36: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 39

Интуитивный графический интерфейс

Page 37: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 40

Интуитивный графический интерфейс

Page 38: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 41

Интуитивный графический интерфейс

Page 39: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 42

Offline

Visually identify

hardware areas of

concern

Интуитивный графический интерфейс

Page 40: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

IBM Customer Presentation

Интуитивный графический

интерфейс

43

Easy-to-use GUI More Difficult More Difficult

Page 41: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Дополнительное управление

44

DS8100,

DS8300,

DS8700,

DS8800

Brocade Fibre

Channel switches

BladeCenter

Power Systems

System x Power

Systems

Director + Storage Control

IBM SVC Storwize V7000

System z

DS3400, DS3500, DS4100, DS4200,

DS4300, DS4400, DS4500, DS4700, DS4800,

DS5020, DS5100, DS5300,

Included in Base Director

DS6800

Included in

Base Director

Page 42: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 45

Для организаций которым необходимо управление

Встроенный веб-интерфейс:

Для более сложных окружений: Tivoli Storage Productivity Center (TPC)

Admin

TPC/SSPC IBM

TS3500

TS3310

IBM

TS3500

TS3310

IBM DS8000IBM DS8000

IBM

DS3000

DS4000

DS5000

IBM

DS3000

DS4000

DS5000

IBM SVCIBM SVC

Storage Admin

Вариант # 1

Вариант # 2

Page 43: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 46

Для организаций которым нужно управление всей

инфраструктурой

Интегрированное управление серверами и СХДt: Systems Director + Storage Control

IBM

TS3500

TS3310

IBM

TS3500

TS3310

IBM DS8000IBM DS8000

IBM

DS3000

DS4000

DS5000

IBM

DS3000

DS4000

DS5000

IBM SVCIBM SVC

Servers

StorageSystems Director

+Storage Control“Systems” Admin

Вариант # 3

Page 44: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Tivoli Storage Productivity Center ME: Анализ и мониторинг Для StorwizeV7000 Rapid Application Storage

Понимание

инфраструктуры

Планирование

Утилизация

дисковых

ресурсов

Узкие места

Управление электропитанием

Мониторинг

производительности и

состояния

Page 45: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Storwize V7000

Обзор компонентов

48

Page 46: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Storwize V7000 – Обзор компонентов

Единое шасси для контроллеров и дисковых полок в форм-факторе 2U

49

Page 47: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Storwize V7000 – Обзор компонентов

50

Дисковая/контроллерная полка – 12 дисков 3.5 дюйма

2076-112/212

Дисковая/контроллерная полка – 24 дисков 2.5 дюйма

2076-124/224

Page 48: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Дисковая полка (вид сзади)

2076-212/224

Контроллерная полка(вид сзади)

2076-112/124

Storwize V7000 Обзор компонентов

51

The power cooling module or PCM for

the control enclosure includes

batteries to protect the cache in the.

Верхний

контроллер.

Модули питания и охлаждения.

Включают батареи для защиты кэша

контроллеров..

The power cooling module or PCM

Нижний

контроллер

Верхний I/O

модуль

Нижний I/O

модуль

Модули питания и охлаждения

Page 49: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Дисковая полка (вид сзади)

2076-212/224

Контроллерная полка(вид сзади)

2076-112/124

Storwize V7000 Обзор компонентов

52

Два 6Gbps SAS порта

для подключения к

контроллерам или

дисковым полкам

Четыре 8Gbps FC

порта для

подключения серверов

Четыре 8Gbps FC

порта для

подключения серверов

Два порта gigE для

подключения по iSCSI

и два USB.

Два порта gigE для

подключения по iSCSI

и два USB.

Два 6Gbps SAS порта

для подключения

дисковых полок

Expansion slot for

possible future growth to

Слот расширения для

будущих апгрейдов.

Дополнительные FC

порты и 10Gig Ethernet.

Два 6Gbps SAS порта

для подключения

дисковых полок

Два 6Gbps SAS порта

для подключения к

контроллерам или

дисковым полкам

Два 6Gbps SAS порта

для подключения к

контроллерам или

дисковым полкам

Два 6Gbps SAS порта

для подключения к

контроллерам или

дисковым полкам

Page 50: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

SAS 1.0 и 2.0

Некоторые производители используют SAS 1.0 в своих системах хранения.

SAS 1.0 привлекателен, за счет низкой стоимости, но цена достигается отсутствием важных функций которые присутствуют в FC дисках.

Некоторые производители используют также SAS 2.0 в своих системах хранения, но их системы выглядят только как SAS Ready, но полностью не соответствуют стандарту.

Storwize V7000 построен на SAS 2.0 6Gb/s и работает только на 6Gbps.

53

Serviceability Feature

Support Pure

6Gb/s

SAS

2.0

4Gb/s

FC

3Gb/s

SAS

1.0

3Gb/s

SAS

2.0

Drive Channel Health Monitoring YES YES YES YES

Collect All Port Statistics YES YES YES YES

Retrieve Drive Diagnostic Data YES YES YES YES

Cabling Error Mis-Wire Detection and

Notification YES YES YES YES

Degraded Wide Port Notification N/A YES YES YES

Automatically Disable Faulty Port YES YES YES YES

Drive Channel Initialization Storm

Protection YES NO NO YES

Maintain History of Port Statistics YES NO NO YES

Proactive Drive Health Monitoring YES NO NO YES

SATA Drive SMART Event Polling YES NO NO YES

Slow PHY Speed Detection YES NO NO YES

Drive Port Fault Protection YES NO NO YES

Controller FRU Fault Isolation

Diagnostics YES NO NO YES

T10 PI and 520B Support with

Recovered Error Limits Yes NO NO YES

Improved Redundant Drive Path Fault

Tolerance NO NO NO YES

Controller to Controller Channel Fault

Protection NO NO NO YES

Page 51: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

SAS Контроллеры и Экспандеры

SAS Expander это практически свитч с топологией точка – точка

В каждой полке два экспандера для отказоустойчивости

54

Page 52: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Storwize V7000 функционал

Thin Provisioning – Включено

FlashCopy – Включено

Easy Tier – Включено

Metro and/or Global Mirror – Опционально

External Virtualization – Опционально

Page 53: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

56

IBM Storage Plug-in for Vmware

Page 54: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

VAAI (vStorage APIs for Array Integration)

Это комплекс технологий компании VMware,

разработанный в сотрудничестве с

производителями дисковых массивов,

предназначенный для передачи некоторых

операций виртуальных машин по работе с дисками

на сторону массива

57

Page 55: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 5

8

vCenter Plug-in Features

Просто определить информацию на СХД

– Кому в XIV предоставлены LUN

– Как созданы Pool

– Отчетность об объеме

Обеспечение хранения для ESX серверов

– Создание Томов для vCenter

– Предоставление томов для ESX Hosts

Монитор снимков и репликации данных

– Точки восстановления данных

– Последние Снимки

Управление множественными multiple системами

Выдача прав администраторам для управления массивом

Page 56: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 59

Page 57: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 60

Создание Тома

Page 58: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 61

До и после….

Page 59: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

VAAI (vStorage APIs for Array Integration) Benefits

Full Copy / Clone Blocks /

XCOPY – функция,

позволяющая передать на

сторону массива возможности

копирования объектов

виртуальной инфраструктуры

без задействования операций

четния-записи со стороны

сервера «Hardware Offloaded

Copy» и «SAN Data Copy

Offloading»

Write Same / Zero Blocks – возможность

обнуления больших блоков массивов на

дисковых устройствах для быстрого

создания дисков vmdk типа eager zero

thick

Atomic Test and Set (ATS) –возможность

защиты метаданных тома VMFS как

кластерной файловой системы в

ситуациях, когда большое количество

хостов ESX имеют разделяемый доступ к

одному хранилищу. Также эта функция

называется Hardware Assisted Locking.

Page 60: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

63

Page 61: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Full Copy

Inst

ruct

ion

Dat

a C

opy D

ata Copy In

stru

ctio

n

Data Copy

HW Copy

Enabled

Full Copy\Полная копия

Изменения путей для

копирования данных и

миграции

Высоко улучшенная

производительность,

гораздо меньше загружает

процессор на ESX

XIV Advantage

Лучшей производительности на XIV по

сравнению с другими СХД, команда

хсору выполняется по всем дискам.

Page 62: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Block Zeroing

Zero

Block Zeroing

Enabled

0 0 0 0 0

Zero

Ze

ro

Zero

Zer

o

0 0 0 0 0Zero

Zero

Block Zeroing

Уменьшение расходов

IOPS и CPU на создание

EZT (Eager Zeroed Thick)

VMDKs

Why EZT?

Маленький расход IO (после

создания)

Несколько более высокая

производительность

VMware Fault Tolerance for

vSphere 4 использует EZT

Page 63: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Hardware Assisted Locking

V

M

D

K

V

M

D

K

V

M

D

K

Host can’t access

LUN during lock

Hardware Locking

Enabled

V

M

D

K

V

M

D

K

V

M

D

K

Lock

Full LUN locked

Only VMDKs

locked

Lock

Lo

ck

Lo

ck

Hardware Assisted Locking

More granular locking

Improved performance

Better cluster scalability

Sample locks events

VM migrate, SVM

Power on/off

New VM or VMDK

Page 64: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 67

VMDK файлы могут быть в одном из 4х режимов.

Отличаются эти режимы следующим:

Когда размечаются блоки под них

Когда затираются блоки(обнуляются, zeroed).

ZeroedThick Thick EagerZeroedThick Thin

Разметка При создании При создании При создании По запросу

Обнуление

При первой

операции записи

на блок

Нет При создании диска Перед первой операцией

записи

Используется в случае Во всех типовых Для кворумных

дисков MSCS

Для кворумных дисков MSCS Когда хотим поэкономить

место на LUN.

(дольше создается, чем в

формате

Если vmdk создается на NFS

хранилище,

Thick, но является более

рекомендованным)

то по умолчанию он создается

в этом формате

.

Page 65: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 68

Как включить VMware vSphere VAAI

На хостах ESX / ESXi по умолчанию VAAI включена. Проверить это можно,

перейдя в Configuration > Advanced Settings и увидев следующие

параметры, напротив которых стоят единицы:

• DataMover/HardwareAcceleratedMove (это возможности Full Copy)

• DataMover/HardwareAcceleratedInit (это Zero Block)

• VMFS3/HardwareAcceleratedLocking (это ATS)

Page 66: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 69

# esxcfg-advcfg -g /DataMover/HardwareAcceleratedMove

# esxcfg-advcfg -g /DataMover/HardwareAcceleratedInit

# esxcfg-advcfg -g /VMFS3/HardwareAcceleratedLocking

Или можно проверить из командной строки:

Command Line SSH

Display Name: Local VMware Disk (mpx.vmhba2:C0:T0:L0)

VAAI Status: supported

Display Name: Local USB CD-ROM (mpx.vmhba32:C0:T0:L0)

VAAI Status: unknown

Display Name: Local TEAC CD-ROM (mpx.vmhba3:C0:T0:L0)

VAAI Status: unknown

Display Name: DGC Fibre Channel Disk (naa.6006016030801c00f8506073d0d7de11)

VAAI Status: unknown

Display Name: DGC Fibre Channel Disk (naa.6006016030801c00f9506073d0d7de11)

VAAI Status: unknown

# esxcfg-scsidevs -l | egrep "Display Name:|VAAI Status:"

Page 67: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Какая выгода от внедрения IBM Storwize V7000?

Экономит ресурсы хранения

Упрощает управление

Устраняет разницу между технологиями различных производителей

Консолидирует ресурсы хранения

Добавляет функционал и производительность ко всем имеющимся

дисковым массивам(ресурсам)

Поддерживает репликацию и перемещение данных без остановки

сервисов

Добавляет многоуровневое хранение

70

Page 68: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 71

innovation that matters

Вопросы и ответы

Page 69: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 72

Thank You!

Doronchenkov Grigory

STG Storage Technical Sales Specialist

[email protected]

Спасибо за внимание Узнайте больше:

ibm.com/storage/storwizev7000

Page 70: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation

Scale horizontally (scale out) VS Scale vertically (scale up)

Горизонтальное масштабирование VS Вертикальное

масштабирование

73

Вертикальное масштабирование

Увеличение производительности каждого компонента

системы c целью повышения общей производительности.

Горизонтальное масштабирование

Разбиение системы на более мелкие структурные компоненты и

разнесение их по отдельным физическим машинам (или их группам)

и/или увеличение количества контроллеров (серверов) параллельно

выполняющих одну и ту же функцию.

Page 71: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 74 74

Legal Information and Trademarks The following terms are trademarks of International Business Machines Corporation in the United States, other countries, or both:

IBM, IBM Logo, on demand business logo, Enterprise Storage Server, xSeries, BladeCenter, eServer, ServeRAID and

FlashCopy

IBM, the IBM logo, ibm.com, IBM System Storage, are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Storwize,

storwize.com and the Storwize logo are trademarks of Storwize Inc., an International Business Machines Corp. company, and may be registered in many jurisdictions

worldwide, and used under license by International Business Machines Corp. A current list of IBM trademarks is available on the Web at "Copyright and trademark

information" at http://www.ibm.com/legal/copytrade.shtml

The following are trademarks or registered trademarks of other companies.

Intel is a trademark of the Intel Corporation in the United States and other countries.

Java and all Java-related trademarks and logos are trademarks or registered trademarks of Sun Microsystems, Inc., in the United States and other countries.

Lotus, Notes, and Domino are trademarks or registered trademarks of Lotus Development Corporation.

Linux is a registered trademark of Linus Torvalds.

Microsoft, Windows and Windows NT are registered trademarks of Microsoft Corporation.

SET and Secure Electronic Transaction are trademarks owned by SET Secure Electronic Transaction LLC.

UNIX is a registered trademark of The Open Group in the United States and other countries.

* All other products may be trademarks or registered trademarks of their respective companies.

Notes:

Performance is in Internal Throughput Rate (ITR) ratio based on measurements and projections using standard IBM benchmarks in a controlled environment. The

actual throughput that any user will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O

configuration, the storage configuration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput

improvements equivalent to the performance ratios stated here.

IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply.

All customer examples cited or described in this presentation are presented as illustrations of the manner in which some customers have used IBM products and the

results they may have achieved. Actual environmental costs and performance characteristics will vary depending on individual customer configurations and

conditions.

This publication was produced in the United States. IBM may not offer the products, services or features discussed in this document in other countries, and the

information may be subject to change without notice. Consult your local IBM business contact for information on the product or services available in your area.

All statements regarding IBM's future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

Information about non-IBM products is obtained from the manufacturers of those products or their published announcements. IBM has not tested those products and

cannot confirm the performance, compatibility, or any other claims related to non-IBM products. Questions on the capabilities of non-IBM products should be

addressed to the suppliers of those products.

Prices subject to change without notice. Contact your IBM representative or Business Partner for the most current pricing in your geography.

This presentation and the claims outlined in it were reviewed for compliance with US law. Adaptations of these claims for use in other geographies must be reviewed

by the local country counsel for compliance with local laws.

Page 72: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 75 75

Notices and Disclaimers

Copyright © 2010 by International Business Machines Corporation. All rights reserved.

No part of this document may be reproduced or transmitted in any form without written permission from IBM Corporation.

Product data has been reviewed for accuracy as of the date of initial publication. Product data is subject to change without notice. This

document could include technical inaccuracies or typographical errors. IBM may make improvements and/or changes in the product(s) and/or

program(s) described herein at any time without notice. Any statements regarding IBM's future direction and intent are subject to change or

withdrawal without notice, and represent goals and objectives only. References in this document to IBM products, programs, or services does

not imply that IBM intends to make such products, programs or services available in all countries in which IBM operates or does business. Any

reference to an IBM Program Product in this document is not intended to state or imply that only that program product may be used. Any

functionally equivalent program, that does not infringe IBM's intellectually property rights, may be used instead.

THE INFORMATION PROVIDED IN THIS DOCUMENT IS DISTRIBUTED "AS IS" WITHOUT ANY WARRANTY, EITHER OR IMPLIED. IBM

LY DISCLAIMS ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT. IBM

shall have no responsibility to update this information. IBM products are warranted, if at all, according to the terms and conditions of the

agreements (e.g., IBM Customer Agreement, Statement of Limited Warranty, International Program License Agreement, etc.) under which they

are provided. Information concerning non-IBM products was obtained from the suppliers of those products, their published announcements or

other publicly available sources. IBM has not tested those products in connection with this publication and cannot confirm the accuracy of

performance, compatibility or any other claims related to non-IBM products. IBM makes no representations or warranties, ed or implied,

regarding non-IBM products and services.

The provision of the information contained herein is not intended to, and does not, grant any right or license under any IBM patents or

copyrights. Inquiries regarding patent or copyright licenses should be made, in writing, to:

IBM Director of Licensing

IBM Corporation

North Castle Drive

Armonk, NY 1 0504- 785

U.S.A.

Page 73: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 76

http://www-

933.ibm.com/support/fixcentral/swg/selectFixes?parent=ibm/Storage_Disk&pr

oduct=ibm/Storage_Disk/IBM+Storwize+V7000+(2076)&release=All&platform

=All&function=all

Video demo

http://www-

03.ibm.com/systems/data/flash/storage/disk/demos/integration_vCenter.html

Vmware vcenter plugin Storvize V7000, Xiv

http://www-933.ibm.com/support/fixcentral/

Page 74: IBM Storwize V7000 - asa-it.ru · Non-disruptive Data Migration ... Hitachi Thunder TagmaStore AMS, WMS, USP, USP-VDS VSP EMC CLARiiON CX4, Symmetrix,DCS DMX, VMAX, VNX, VNXe Microsoft

© 2010 IBM Corporation IBM Customer Presentation 77 77

This document was developed for IBM offerings in the United States as of the date of publication. IBM may not make these offerings available in

other countries, and the information is subject to change without notice. Consult your local IBM business contact for information on the IBM offerings

available in your area.

Information in this document concerning non-IBM products was obtained from the suppliers of these products or other public sources. Questions on

the capabilities of non-IBM products should be addressed to the suppliers of those products.

IBM may have patents or pending patent applications covering subject matter in this document. The furnishing of this document does not give you

any license to these patents. Send license inquires, in writing, to IBM Director of Licensing, IBM Corporation, New Castle Drive, Armonk, NY 10504-

1785 USA.

All statements regarding IBM future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.

The information contained in this document has not been submitted to any formal IBM test and is provided "AS IS" with no warranties or guarantees

either expressed or implied.

All examples cited or described in this document are presented as illustrations of the manner in which some IBM products can be used and the

results that may be achieved. Actual environmental costs and performance characteristics will vary depending on individual client configurations

and conditions.

IBM Global Financing offerings are provided through IBM Credit Corporation in the United States and other IBM subsidiaries and divisions

worldwide to qualified commercial and government clients. Rates are based on a client's credit rating, financing terms, offering type, equipment type

and options, and may vary by country. Other restrictions may apply. Rates and offerings are subject to change, extension or withdrawal without

notice.

IBM is not responsible for printing errors in this document that result in pricing or information inaccuracies.

All prices shown are IBM's United States suggested list prices and are subject to change without notice; reseller prices may vary.

IBM hardware products are manufactured from new parts, or new and serviceable used parts. Regardless, our warranty terms apply.

Any performance data contained in this document was determined in a controlled environment. Actual results may vary significantly and are

dependent on many factors including system hardware configuration and software design and configuration. Some measurements quoted in this

document may have been made on development-level systems. There is no guarantee these measurements will be the same on generally-

available systems. Some measurements quoted in this document may have been estimated through extrapolation. Users of this document should

verify the applicable data for their specific environment.

Special notices

Revised September 26, 2006