I68E-EN-03+V1000+Datasheet - Farnell · PDF fileUSB Cable 24VDC Control Board Power Supply...
Transcript of I68E-EN-03+V1000+Datasheet - Farnell · PDF fileUSB Cable 24VDC Control Board Power Supply...
1V1000
VZ
V1000More performance & Quality in less space• Current vector control• High starting torque (200% / 0.5 Hz)• 1:100 speed control range• Double rating ND 120%/1min and HD 150%/1 min• IM&PM motor control• Online Tuning• Low-noise Low carrier technology• 10 years lifetime design• Built-in filter• Screw-less terminals• Control Terminals with memory backup• Fieldbus communications: Modbus, Profibus, CANopen,
DeviceNet, LONworks, CompoNet, Ethernet, ML-II, PROFINET and EtherCAT
• Safety embedded: EN954-1 safety cat. 3, EN6158 SIL II and EN60204-1 Stop category 0
• CE, UL, cUL and TUV
Ratings• 200 V Class single-phase 0.1 to 4 kW• 200 V Class three-phase 0.1 to 15 kW• 400 V Class three-phase 0.2 to 15 kW
System configuration
Copy
Verify
Read
LOCK
YASKAWA
JVOP-181
USB Copy Unit
COMERR
LCD Remote Operator
MCCB
V1000
Filter
Input AC Reactor
Motor
Ground
Power Supply
CX-Drive CX-One
RJ-45 / USB Adapter
Remote Operator Extansion Cable
USB Cable
24VDC Control Board Power Supply
Communication Option Board
Braking Resistor
DC reactor
Mounting Accesories
Output AC Reactor
RS232 Communications cable with PC
Choke
2 Frequency inverters
Type designation
200 V class
400 V class
Specifications
Single-phase: VZA@ B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B4P01
1. Only HD settings is available for this model
- - - -
Three-phase: VZA@ 20P1 20P2 20P4 20P7 21P5 22P2 24P0 25P5 27P5 2011 2015
Motor kW2
2. Based on a standard 4-pole motor for maximum applicable motor output:Heavy Duty (HD) mode with a 150% overload capacityNormal Duty (ND) mode with a 120% overload capacity
For HD setting 0.12 0.25 0.4 1.1 1.5 2.2 4.0 5.5 7.5 11 15For ND setting 0.18 0.37 0.55 1.1 2.2 3.0 5.51 7.5 11 15 18.5
Ou
tpu
t ch
arac
teri
stic
s Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13 18 23
Rated output current (A) at HD 0.8 1.6 3.0 5.0 8.0 11.0 17.5 25.0 33.0 47.0 60.0
Rated output current (A) at ND 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Max. output voltage Proportional to input voltage: 0..240 V
Max. output frequency 400 Hz
Po
wer
su
pp
ly
Rated input voltageand frequency
Single-phase 200..240 V 50/60 Hz3-phase 200..240 V 50/60 Hz
Allowable voltage fluctuation
-15%..+10%
Allowable frequency fluctuation
+5%
Three-phase: VZA@ 40P2 40P4 40P7 41P5 42P2 43P0 44P0 45P5 47P5 4011 4015
Motor kW1
1. Based on a standard 4-pole motor for maximum applicable motor output:Heavy Duty (HD) mode with a 150% overload capacityNormal Duty (ND) mode with a 120% overload capacity
For HD setting 0.37 0.55 1.10 1.5 2.2 3.0 4.0 5.5 7.5 11 15For ND setting 0.37 0.75 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5
Ou
tpu
t ch
arac
teri
stic
s Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.2 9.2 14.8 18 24
Rated output current (A) at HD 1.2 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24 31
Rated output current (A) at ND 1.2 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23 31 38
Max. output voltage 0..480 V (proportional to input voltage)
Max. output frequency 400 Hz
Po
wer
sup
ply
Rated input voltageand frequency
3-phase 380..480 VAC, 50/60 Hz
Allowable voltagefluctuation
-15%..+10%
Allowable frequencyfluctuation
+5%
V1000 series
A: Standard specs
V Z A B 0 P 1 B A AVersion
Enclosure, Fin, Filter:B: IP20 without top coverF: Nema 1E: IP20 without top cover and C3 filter
Voltage:B: Single-phase 200 VAC2: Three-phase 200 VAC4: Three-phase 400 VAC
Z: European standard specifications
Coating specs:A: Standard
[”P” indicates a decimal point] Max. applicable motor output0P1: 0.1 kW ~
015: 15 kW
V1000 3
Common specifications
Specifications
Model numberVZA@
Specifications
Co
ntr
ol f
un
ctio
ns
Control methods Sine wave PWM (V/f control, sensorless current vector control)
Output frequency range 0.1..400 Hz
Frequency toleranceDigital set value: ±0.01% (-10..+50 ºC)Analogue set value: ±0.1% (25 ±10 ºC)
Resolution of frequency set valueDigital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz)
Analogue set value: 1/1000 of maximum frequency
Resolution of output frequency 0.01 Hz
Overload capabilityHeavy duty use: 150% rated output current for one minuteNormal duty use: 120% rated output current for one minute
Frequency set value0..10 V (20 k), 4..20 mA (250 ), 0..20 mA (250 )Pulse train input, frequency setting value (selectable)
Braking torque(short term peak torque)
Short-term average deceleration torque: 150% (up 1.5 kW), 100% (for 1.5 kW), 50% (for 2.2 kW), 20% (for bigger size)Continuous regenerative torque: Approx 20% (125% with optional braking resistor, 10%ED, 10 s, braking transistor built in)
V/f Characteristics Possible to program any V/f pattern
Fu
nct
ion
alit
y
Inputs signals
Seven of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock, speed search com-
mand, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/control circuit terminal selection, emergency stop fault, emergency stop alarm, self test
Output signals
Following output signals are selectable (NO/NC contact output, 2 photo-coupler outputs): Fault, running, zero speed, speed agree, frequency detection (output frequency <= or => set value), during overtorque detection, minor error, during baseblock, operation mode, inverter run ready, during fault retry, during undervoltage detection, reverse running, during speed search,
data output through communication.
Standard functions
Open-loop vector control, full-range automatic torque boost, slip compensation, 17-step speed operation (max.), restart after momentary power loss, DC injection braking current at stop/start (50% of inverter rated current, 0.5 sec, or less), frequency reference bias/gain, MEMOBUS communications (RS-485/422, max. 115K bps), fault retry, speed search, frequency upper/lower limit setting, overtorque detection, frequency jump, accel/decel time switch, accel/decel prohibited, S-curve accel/decel,
PID control, energy-saving control, constant copy.
Analogue inputs 2 analogue inputs, 0..10 V, 4..20 mA, 0..20 mA
Braking/acceleration times 0.01..6000 s
DisplayOptionally frequency, current or set value
Error and status LED
Pro
tect
ion
fu
nct
ion
s
Motor overload protection Electronic thermal overload relay
Instantaneous overcurrent Motor coasts to a stop at approx. 250% of inverter rated current
Overload Heavy Duty: Motor coasts to a stop after 1 minute at 150% of inverter rated output currentNormal Duty: Motor coasts to a stop after 1 minute at 120% of inverter rated output current
Overvoltage Motor coasts to a stop if DC bus voltage exceed 410 V (double for 400 V class)
Undervoltage Stops when DC bus voltage is approx. 190 V or less (double for 400 V class)(approx. 150 V or less for single-phase series)
Momentary power loss Following items are selectable: not provided (stop if power loss is 15 ms or longer), continuous operation if power loss is approx. 0.5 s or shorter, continuous operation
Cooling fin overheat Protected by thermistor
Stall prevention level Stall prevention during acceleration/deceleration and constant speed operation
Ground fault Protected by electronic circuit (operation level is approx. 250% of rated output current)
Power charge indication Indicates until the main circuit voltage reaches 50 V.
Am
bie
nt
con
dit
ion
s Degree of protection IP20, NEMA1
CoolingCooling fan is provided for 200 V, 0.75 kW (1HP) (3/single-phase)
400 V, 1.5 kW (2HP) (3-phase), others are self-cooling
Ambient humidity 95% RH or less (without condensation)
Storage temperature -20 ºC..+60 ºC (short-term temperature during transportation)
Installation Indoor (no corrosive gas, dust, etc.)
Installation height Max. 1000 m
Vibration Up to 9.8 m/s2 at 10 to less than 20 Hz, Up to 6.37 m/s2 at 20 to 50 Hz
4 Frequency inverters
IP20 type
V1000 + Option board (Communication and 24 VDC power supply)
Communication option boards PS-V10S PS-V10M 24 VDC Power supply Options
Dimensions
Voltage class Max. applicable motor output kW Inverter model VZA@ Figure
Dimensions in mm
W1 H1 W H D t1 H2 D1 H3 H4 Weightkg
Single-phase 200 V
0.12 B0P1
1 56
118
68
128
76 3
5
6.5
- -
0.6
0.25 B0P2 0.7
0.55 B0P4 108
5
38.5 1.0
1.1 B0P7
2
96 108 137.5
581.7
1.5 B1P5 154 1.8
2.2 B2P2 128 140 16365
2.4
4.0 B4P0 158 170 180 3.0
Three-phase 200 V
0.12 20P1
1 56
118
68
128
76 3
5
6.5
- -
0.6
0.25 20P2 0.6
0.55 20P4 108
5
38.50.9
1.1 20P7 128 1.1
1.5 21P5
296 108
12958
1.3
2.2 22P2 137.5 1.4
4.0 24P0 128 140 143 65 2.1
5.5 25P5
3
122 248 140 254 140
-
6 55 136.2
3.8
7.5 27P5 3.8
11 2011 160 284 180 290 163 8 7515
5.5
15 2015 192 336 220 358 187 7 78 7.2 9.2
Three-phase400 V
0.37 40P2
296
118108
128
81
5 5
10
- -
0.8
0.55 40P4 99 28 1.0
1.1 40P7 137.5
58
1.4
1.5 41P5
154
1.5
2.2 42P2 1.5
3.0 43P0 1.5
4.0 44P0 128 140 143 65 2.1
5.5 45P5
3
122 248 140 254 140
-
655
136 3.8
7.5 47P5 6.2 3.8
11 4011160 284 180 290
1438 15 6
5.2
15 4015 163 75 5.5
t1
DD1
4-M4
H
W1
W H2
H1
Figure 1 Figure 2
D1
t1
D
2-M4W1
H1
H2
W
H
34
118
34
128
V1000 5
Built-in filter
Schaffner footprint filters
VZA@Dimensions in mm
W H H1 D1 D2 D
B0P1
68+
178 50
69.5 6.5 76B0P2
B0P4 79.5 38.5 118
B0P7108
77.9 59.6 137.5
B1P5 89.4 64.6 154
B2P2 140 183 55 96.4 66.6 16340P2
108 178 50
69.4 11.6 81
40P4 29.6 9940P7 77.9
59.6
137.541P5
94.4 15442P243P044P0 140 183 55 76.4 66.6 143
Schaffner standard modelDimensions in mm Weight
kgA B C D E F G H I J K L
1x200 V
A1000-FIV1010-SE 169 71 45 135 156 51 5.3 M5 22 56 118 M4 0.44
A1000-FIV1020-SE 169 111 50 135 156 91 5.3 M5 25 96 118 M4 0.8
A1000-FIV1030-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4 1.2
A1000-FIV1040-SE 174 174 50 135 161 150 5.3 M5 25 158 118 M4 1.6
3x200 V
A1000-FIV2010-SE 194 82 40 135 181 62 5.5 M5 20.5 56 118 M4 0.4
A1000-FIV2020-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 0.58
A1000-FIV2030-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4 0.9
A1000-FIV2060-SE 305 144 56 264 289 122 6.5 M5 28 122 248 M5 2.0
A1000-FIV2080-SE 345 182 65 300 325 160 6.5 M6 32.5 160 285 M5 2.6
A1000-FIV2100-SE 394 214 65 353 378 192 6.5 M8 32.5 192 336 M6 3.1
3x400 V
A1000-FIV3005-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 0.5
A1000-FIV3010-SE 169 111 45 135 156 91 5.3 M5 22 96 118 M4 0.7
A1000-FIV3020-SE 174 144 50 135 161 120 5.3 M5 25 128 118 M4 0.9
A1000-FIV3030-SE 305 144 56 264 289 122 6.5 M5 28 122 248 M5 1.8
A1000-FIV3050-SE 341 182 65 300 325 160 6.5 M6 32.5 160 285 M5 2.7
6 Frequency inverters
Rasmi footprint filters
Remote LCD operator
Schaffner low leakage modelDimensions in mm Weight
kgA B C D E F G H I J K L
1x200 V
A1000-FIV1010-SE-LL 166 70 40 130 156 51 5.3 M5 20 56 118 M4 0.33
A1000-FIV1020-SE-LL 166 110 50 130 156 91 5.3 M5 25 96 118 M4 0.72
A1000-FIV1030-SE-LL 170 142 50 130 161 120 5.3 M5 25 128 118 M4 0.92
A1000-FIV1040-SE-LL 173 176 50 135 161 150 5.3 M5 25 158 118 M4 1.4
3x200 V
A1000-FIV2010-SE-LL 191 80 40 130 181 62 5.3 M5 20 56 118 M4 0.35
A1000-FIV2020-SE-LL 166 110 50 130 156 91 5.3 M5 25 96 118 M4 0.65
A1000-FIV2030-SE-LL 172 142 50 130 161 120 5.3 M5 25 128 118 M4 0.92
3x400 V
A1000-FIV3005-SE-LL 166 110 45 130 156 91 5.3 M5 22.5 96 118 M4 0.5
A1000-FIV3010-SE-LL 166 110 45 130 156 91 5.3 M5 22.5 96 118 M4 0.66
A1000-FIV3020-SE-LL 171 142 45 130 161 120 5.3 M5 22.5 128 118 M4 0.85
A1000-FIV3030-SE-LL 304 140 55 263 290 122 6.5 M5 27.5 122 248 M5 1.85
A1000-FIV3050-SE-LL 344 180 55 300 330 160 6.5 M6 27.5 160 285 M5 2.65
Rasmi standard and low leakage modelDimensions in mm Weight
kgW H L X Y M
1x200 V
A1000-FIV1010-RE@ 71 45 169 156 51 M4 0.6
A1000-FIV1020-RE@ 111 50 169 156 91 M4 1.0
A1000-FIV1030-RE@ 144 50 174 161 120 M4 1.2
A1000-FIV1040-RE@ 174 50 174 161 150 M4 1.5
3x200 V
A1000-FIV2010-RE@ 82 50 194 181 62 M4 1.0
A1000-FIV2020-RE@ 111 50 169 156 91 M4 1.1
A1000-FIV2030-RE@ 144 50 174 161 120 M4 1.2
A1000-FIV2060-RE@ 150 52 320 290 122 M5 2.8
A1000-FIV2080-RE@ 188 62 362 330 160 M5 4.5
A1000-FIV2100-RE@ 220 62 415 380 192 M6 4.5
3x400 V
A1000-FIV3005-RE@ 111 45 169 156 91 M4 1.0
A1000-FIV3010-RE@ 111 45 169 156 91 M4 1.0
A1000-FIV3020-RE@ 144 50 174 161 120 M4 1.7
A1000-FIV3030-RE@ 150 52 306 290 122 M5 2.0
A1000-FIV3050-RE@ 182 62 357 330 160 M5 2.8
<1>
90 (3
.54)
78 (3
.07)
60 (2.36) 7.9(0.31)
minimum 50 (1.96) Unit : mm (in)
12.2(0.48)
1.6 (0.06)Installation holes (2-M3 screws, depth 5 (0.19))
44 (1.73)
15 (0
.59)
V1000 7
Input AC Reactor
Single-phase
Three-phase
DC Reactor
Voltage ReferenceDimensions Weight
kgA B C D E F G H
200 V
AX-RAI02000070-DE 84 113 96 101 66 5 7.5 2 1.22AX-RAI01700140-DE 84 113 116 101 66 5 7.5 2 1.95AX-RAI01200200-DE 84 113 131 101 66 5 7.5 2 2.55AX-RAI00630240-DE 84 113 116 101 66 5 7.5 2 1.95
Voltage ReferenceDimensions Weight
kgA B2 C2 D E F
200 V
AX-RAI02800080-DE 120 70 120 80 52 5.5 1.78AX-RAI00880200-DE 120 80 120 80 62 5.5 2.35AX-RAI00350335-DE 180 85 190 140 55 6 5.5AX-RAI00180670-DE 180 85 190 140 55 6 5.5
400 V
AX-RAI07700050-DE 120 70 120 80 52 5.5 1.78AX-RAI03500100-DE 120 80 120 80 62 5.5 2.35AX-RAI01300170-DE 120 80 120 80 62 5.5 2.50AX-RAI00740335-DE 180 85 190 140 55 6 5.5
Voltage ReferenceDimensions Weight
kgA B C D E F G H
200 V
AX-RC21400016-DE
84 113
96
101 66 5 7.5 2
1.22AX-RC10700032-DEAX-RC06750061-DE
105 1.60AX-RC03510093-DEAX-RC02510138-DE 116 1.95AX-RC01600223-DE 108 135 124 120 82 6.5
9.59.5 3.20
AX-RC01110309-DE120 152
136135 94
7 -
5.20AX-RC00840437-DE 146 6.00AX-RC00590614-DE
150 177160
160 115 211.4
AX-RC00440859-DE 182.6 14.3
400 V
AX-RC43000020-DE
84 113
96
101 66 5 7.5 2
1.22AX-RC27000030-DE
105 1.60AX-RC14000047-DEAX-RC10100069-DE 116 1.95AX-RC08250093-DE 131 2.65AX-RC06400116-DE 108 135 133 120 82 6.5
9.59.5 3.70
AX-RC04410167-DE120 152
136135 94 7
-
5.20AX-RC03350219-DE 146 6.00AX-RC02330307-DE
150 177160
160 115 7 211.4
AX-RC01750430-DE 182.6 14.3
8 Frequency inverters
Output AC Reactor
Chokes
Resistor Dimensions
Voltage ReferenceDimensions Weight
kgA B2 C2 D E F
200 V
AX-RAO11500026-DE 120 70 120 80 52 5.5 1.78AX-RAO07600042-DE 120 70 120 80 52 5.5 1.78AX-RAO04100075-DE 120 80 120 80 62 5.5 2.35AX-RAO03000105-DE 120 80 120 80 62 5.5 2.35AX-RAO01830180-DE 180 85 190 140 55 6 5.5AX-RAO01150220-DE 180 85 190 140 55 6 5.5AX-RAO00950320-DE 180 85 205 140 55 6 6.5AX-RAO00630430-DE 180 95 205 140 65 6 9.1AX-RAO00490640-DE 180 95 205 140 65 6 9.1
400 V
AX-RAO16300038-DE 120 70 120 80 52 5.5 1.78AX-RAO11800053-DE 120 80 120 80 52 5.5 2.35AX-RAO07300080-DE 120 80 120 80 62 5.5 2.35AX-RAO04600110-DE 180 85 190 140 55 6 5.5AX-RAO03600160-DE 180 85 205 140 55 6 6.5AX-RAO02500220-DE 180 95 205 140 55 6 9.1AX-RAO02000320-DE 180 105 205 140 85 6 11.7
DescriptionD
diameterMotor
KWDimensions in mm Weight
kgL W H X Y m
AX-FER2102-RE 21 < 2.2 85 22 46 70 - 5 0.1
AX-FER2515-RE 25 < 15 105 25 62 90 - 5 0.2
AX-FER5045-RE 50 < 45 150 50 110 125 30 5 0.7
Type Fig.Dimensions in mm Weight
L H M I T G N kg
AX-REM00K1400-IE
1
105 27 36 94 - - - 0.2AX-REM00K2070-IE
AX-REM00K2120-IE
AX-REM00K2200-IE
AX-REM00K4035-IE 200 27 36 189 - - - 0.425
AX-REM00K6035-IE 320 27 36 309 - - - 0.73
AX-REM00K9020-IE2 200 61 100 74 211 40 230 1.41
AX-REM00K9017-IE
X
H
YW Ø m
L
Ø d
AX-REM00K1200 Fig 2Fig 1
V1000 9
DIN rail mounting bracket
Inverter VZA@ DIN rail mounting bracket1-phase 200 VAC B0P1/ B0P2/ B0P4 EZZ08122A
B0P7/ B1P5 EZZ08122BB2P2 EZZ08122CB4P0 EZZ08122D
3-phase 200 VAC 20P1/ 20P2 / 20P4/ 20P7 EZZ08122A21P5/ 22P2 EZZ08122B24P0 EZZ08122C
3-phase 400 VAC 40P2/ 40P4/ 40P7/ 41P5/ 42P2 EZZ08122B44P0 EZZ08122C
EZZ08122A EZZ08122B
Four, M4 tap Four, M4 tap
Four, M4 tap Four, M4 tap
EZZ08122C EZZ08122D
Side view (common to all the units)
35.1
DIN
rai
l
10 Frequency inverters
Heatsink attachment and Panel cut dimensions
VZA@ ReferenceFrame Panel Cutting
W H W1 H1 D1 D2 D3 Fig (W2) (W3) (H2) (H3) A B
1X20
0 V
B0P1100-034-075
68
128
56
118
69.2 12 302 -B0P2
B0P4 100-034-076 79.2 42 50B0P7 100-035-418
108 9679.5
5870
3 -B1P5 100-034-079 96B2P2 100-034-080 140 128 98
654 -
B4P0 100-036-357 170 158 115 -
3x20
0 V
20P1100-034-075
68
128
56
118
69.212 30
2 -20P220P4 100-034-076 42 5020P7 100-034-077 62 7021P5
100-034-079 108 9671
58 70 3 -22P2 79.524P0 100-034-080 140 128 86.5 53.5 60 4 -25P5
100-036-300 158 286 122 272 86.6 53.4 601
99
8.57
140 25527P52011 100-036-301 198 322 160 308 89.6 73.4 80 10 10.5 180 2872015 100-036-302 241 380 192 362 110.6 76.4 85 14 10.5 10.5 9 220 341
3X40
0 V
40P2 100-034-078
108128
96118
71 13.2 30
3 -
40P4100-036-418
28 4040P7 79.5
5870
41P5100-034-079 9642P2
43P044P0 100-034-080 140 128 78 65 4 -45P5
100-036-300158 286 122 272
86.653.4 60
1
9
9
8.5
7
140 25547P5
198 322 160 308 10 10.5 180 2874011100-036-301
4015 73.4 80
Heatsink External Mounting Attachment
Mounting PanelD3 for more
Fig 3 Fig 3 Fig 2 Fig 2 Fig 4 Fig 4Fig 1
2 - 5 Dia. Holes
4-d Tap
V1000 11
Standard connections
Installation
Power Supply
R/L1
S/L2
T/L3
S1
S2
S3
S4
S5
S6
B1+1+2 B2
L1
L2
L3
U/T1
V/T2
W/T3
24 V
0 V
SINK
SOURCE
MA
P1
MB
MC
+24 V 8 mA
M
U
V
W
SC
P2
MP
AM
AC
PC
IG
R+
R−
S+
S−
H2
RP
+V
A1
A2AC
2 kW
HC
H1
DC reactor (option)For 1-phase
power supply use R/L1 and S/L2
Filter
Fuses
Main Switch Forward/Stop
Reverse/Stop
External Fault
Fault Reset
Multi-speed 1
Multi-speed 2
Multi-function digital inputs
(default setting)
Link
Thermal relay
Braking resistor
(opt)
V1000
Ground
Multi-function relay output250 Vac / 30 VDC (10 mA to 1A)(default setting)Fault
During run
Frequency agreePhotocoupler common
Multi-function photo-coupler output48 VDC, max. 50 mA(default setting)
DIPswitch S3
Shielded ground terminal
Pulse Input(max. 32kHz)
Multi-function analog input 10 to 10 V (20 kW)Multi-function analog input 20 to 10 V (20 kW) or0/4 to 20 mA (250 W)
Analog input power supply+10.5 VDC, max. 20 mA
Multi- function pulse / analog inputs(default: frequency reference)
Safe Disable inputs
Monitor outputs(default setting)Analog output
0 to +10 VDC (2mA)(Output frequency)
Pulse train output(max. 32 kHz)(Output frequency)
Terminal resistance(120 W, 1/2 W)
Memobus comm.RS-485/422max. 115 kBps
Shielded Cable
Symbols:Use twisted pair cables
Use shielded twisted pair cables
Indicates a main circuit terminal
Indicates a control circuit terminal.
12 Frequency inverters
Main circuit
Control Circuit
Terminal Name Function (signal level)
R/L1, S/L2, T/L3 Main circuit power supply inputUsed to connect line power to the drive.Drives with single-phase 200 V input power use only terminals R/L1 and S/L2(T/L3 is not connected to anything)
U/T1, V/T2, W/T3 Inverter output Used to connect the motor
B1, B2 Braking resistor connection Available for connecting a braking resistor or the braking resistor unit option.
+2, +1 DC reactor connection Remove the short bar between +2 and +1 when connecting DC reactor (option)
+1, – DC power supply input For power supply input (+1: positive electrode; – : negative electrode)
Grounding For grounding (grounding should conform to the local grounding code.)
Type No. Signal name Function Signal level
Dig
ital
inp
ut
sig
nal
s
S1 Multi-function input selection 1 Factory setting: runs when CLOSED, stops when OPEN.
24 VDC, 8 mA photocoupler insulation
S2 Multi-function input selection 2 Factory setting: runs when CLOSED, stops when OPEN.
S3 Multi-function input selection 3 Factory setting: External Fault (N.O.)
S4 Multi-function input selection 4 Factory setting: Fault reset
S5 Multi-function input selection 5 Factory setting: Multi-step speed cmd 1
S6 Multi-function input selection 6 Factory setting: Multi-step speed cmd 2
SCMulti-function input selection Common Common for control signal
An
alo
g in
pu
t si
gn
als RP Main Speed Cmd Pulse Train Input 32 kHz max.
FS Power Supply for Frequency Setting +10 V (allowable max current 20 mA)
FR1Main Speed Freq Ref
Voltage input or current input0 to +10 VDC (20 k) (resolution 1/1000)4 to 20 mA (250 ) or 0 to 20 mA (250 ) Resolution: 1/500 FR2
FC Frequency reference common 0 V
Fast Stop Cmd
HC Power Supply Fast Stop Cmd +24 V (max allowable current 10 mA)
H1 Special Digital inputOpen: Fast Stop Closed: Normal Operation
H2 Special Digital input
Dig
ital
ou
tpu
t si
gn
als
MA NO contact output
Factory setting: “fault”
Contact capacity250 VAC, 1 A or less30 VDC, 1 A or less
MB NC Output
MC Relay Output common
P1 Photocoupler output 1 Factory setting: During runPhotocoupler output: +48 VDC, 50 mA or less
P2 Photocoupler output 2 Factory setting: Frequency Agree
PC Photocoupler output common 0 V
Analog output signals
PM Pulse train Output max 33 kHz
AM Analog monitor output Factory setting: "output frequency" 0 to +10 V output Resolution: 1/1000 0 to 10 V 2 mA or less Resolution: 8 bitsAC Analog monitor common 0 V
RS
-485
/422
R+ Communication input (+)
For MEMOBUS communicationoperation by RS-485 or RS-422 communication is available.
RS-485/422MEMOBUS protocol
R– Communication input (–)
S+ Communication output (+)
S– Communication output (–)
V1000 13
Inverter heat loss
Single-phase 200 V class
Three-phase 200 V class
Three-phase 400 V class
Model VZA B0P1 B0P2 B0P4 B0P7 B1P5 B2P2 B4P0
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7
Rated current (A) at HD 0.8 1.6 3 5 8 11 17.5
Rated current (A) at ND 1.2 1.9 3.5 6.0 9.6 12.0 -
Hea
t lo
ss W
H
D
Fin 4.3 7.9 16.1 42.5 54.8 70.7 110.5
Inside unit 7.4 8.9 11.5 19.0 25.9 34.1 51.4
Total heat loss 11.7 16.7 27.7 61.5 80.7 104.8 161.9
Hea
t lo
ss W
N
D
Fin 4.7 7.2 15.1 26.2 48.6 57.9 93.3
Inside unit 8.4 9.6 14.3 20.8 29.0 36.3 58.5
Total heat loss 13.1 16.8 28.3 56.5 77.6 94.2 151.8
Cooling Method Self Cooled Fan Cooled
Model VZA 20P1 20P2 20P4 20P7 21P5 22P2 24P0 25P5 27P5 2011 2015
Inverter capacity kVA 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13 18 23
Rated current (A) at HD 0.8 1.6 3 5 8 11 17.5 25 33 47.0 60.0
Rated current (A) at ND 1.2 1.9 3.5 6.0 9.6 12.0 19.6 30.0 40.0 56.0 69.0
Hea
t lo
ss W
H
D
Fin 4.3 7.9 16.1 27.4 54.8 70.7 110.5 231.5 239.5 347.6 437.7
Inside unit 7.3 8.8 11.5 15.9 23.8 30.0 43.3 72.2 81.8 117.6 151.4
Total heat loss 11.6 16.7 27.7 43.3 78.6 100.6 153.8 303.7 321.3 465.2 589.1
Hea
t lo
ss W
N
D
Fin 4.7 7.2 14.0 35.6 48.6 57.9 93.3 236.8 258.8 342.8 448.5
Inside unit 7.9 9.4 13.4 16.9 25.0 29.6 45.0 87.2 11.4 149.1 182.2
Total heat loss 12.6 16.6 28.5 43.1 73.6 87.5 138.2 324.0 370.3 491.9 630.7
Cooling Method Self Cooled Fan Cooled
Model VZA 40P2 40P4 40P7 41P5 42P2 43P0 44P0 45P5 47P5 4011 4015
Inverter capacity kVA 0.9 1.4 2.6 3.7 4.2 5.5 7.2 9.2 14.8 18 24
Rated current (A) at HD 1.2 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 24 31
Rated current (A) at ND 1.2 2.1 4.1 5.4 6.9 8.8 11.1 17.5 23 31 38
Hea
t lo
ss W
H
D
Fin 19.2 28.9 42.3 70.7 81.0 84.6 107.2 166.0 207.1 266.9 319.1
Inside unit 11.4 14.9 17.9 26.2 30.7 32.9 41.5 62.7 78.1 105.9 126.6
Total heat loss 30.6 43.7 60.2 96.9 111.7 117.5 148.7 228.7 285.2 372.7 445.8
Hea
t lo
ss W
N
D
Fin 8.2 15.5 26.4 37.5 49.7 55.7 71.9 170.3 199.5 268.6 298.7
Inside unit 9.2 13.1 15.8 20.0 26.3 29.4 43.6 78.1 105.3 142.8 152.2
Total heat loss 17.4 28.6 42.2 57.5 76.0 85.1 115.5 248.4 304.8 411.4 450.9
Cooling Method Self Cooled Fan Cooled
a: Space required differs by model:Up to 3.7 kW: minimum 30 mm5.5 kW and above: minimum 50 mm
Side by Side mounting
a a
Airflow
At least 100 mm
At least 100 mm
14 Frequency inverters
Connections for braking resistor
Input AC Reactor
DC Reactor
Output AC Reactor
1 phase 200 V class 3 phase 200 V class 400 V classMax. ap-plicable motor
output kW
ReferenceCurrent value
A
Induc-tancemH
Max. ap-plicable motor
output kW
ReferenceCurrent value
A
Induc-tancemH
Max. ap-plicable
motor out-put kW
ReferenceCurrent value
A
Induc-tancemH
0.4 AX-RAI02000070-DE 7.0 2.0 1.5 AX-RAI02800080-DE 8.0 2.8 1.5 AX-RAI07700050-DE 5.0 7.70.75 AX-RAI01700140-DE 14.0 1.7 3.7 AX-RAI00880200-DE 20.0 0.88 4.0 AX-RAI03500100-DE 10.0 3.51.5 AX-RAI01200200-DE 20.0 1.2 7.5 AX-RAI00350335-DE 33.5 0.35 7.5 AX-RAI01300170-DE 17.0 1.32.2 AX-RAI00630240-DE 24.0 0.63 11 AX-RAI00180670-DE 67.0 0.18 11 AX-RAI00740335-DE 33.5 0.74
- 15 AX-RAI00091000-DE 100.0 0.09 15 AX-RAI00360500-DE 50.0 0.36
200 V class 400 V classMax. applicable
motor output kW Reference Current value A
InductancemH
Max. applicable motor output kW Reference Current value
AInductance
mH0.2 AX-RC21400016-DE 1.6 21.4 0.4 AX-RC43000020-DE 2.0 43.00.4 AX-RC10700032-DE 3.2 10.7 0.7 AX-RC27000030-DE 3.0 27.00.7 AX-RC06750061-DE 6.1 6.75 1.5 AX-RC14000047-DE 4.7 14.01.5 AX-RC03510093-DE 9.3 3.51 2.2 AX-RC10100069-DE 6.9 10.12.2 AX-RC02510138-DE 13.8 2.51 3.0 AX-RC08250093-DE 9.3 8.253.7 AX-RC01600223-DE 22.3 1.60 4.0 AX-RC06400116-DE 11.6 6.405.5 AX-RC01110309-DE 30.9 1.11 5.5 AX-RC04410167-DE 16.7 4.417.5 AX-RC00840437-DE 43.7 0.84 7.5 AX-RC03350219-DE 21.9 3.3511.0 AX-RC00590614-DE 61.4 0.59 11.0 AX-RC02330307-DE 30.7 2.3315.0 AX-RC00440859-DE 85.9 0.44 15.0 AX-RC01750430-DE 43.0 1.75
200 V class 400 V classMax. applicable
motor output kW Reference Current value A
InductancemH
Max. applicable motor output kW Reference Current value
AInductance
mH0.4 AX-RAO11500026-DE 2.6 11.50
1.5 AX-RAO16300038-DE 3.8 16.300.75 AX-RAO07600042-DE 4.2 7.601.5 AX-RAO04100075-DE 7.5 4.102.2 AX-RAO03000105-DE 10.5 3.00 2.2 AX-RAO11800053-DE 5.3 11.803.7 AX-RAO01830160-DE 16.0 1.83 4.0 AX-RAO07300080-DE 8.0 7.305.5 AX-RAO01150220-DE 22.0 1.15 5.5 AX-RAO04600110-DE 11.0 4.607.5 AX-RAO00950320-DE 32.0 0.95 7.5 AX-RAO03600160-DE 16.0 3.6011 AX-RAO00630430-DE 43.0 0.63 11 AX-RAO02500220-DE 22.0 2.5015 AX-RAO00490640-DE 64.0 0.49 15 AX-RAO02000320-DE 32.0 2.00
Powersupply
Thermal relay
Motor
VZ
Braking resistor
Thermal relay switch forexternal braking resistor
Fault contact
MC
SA
SA
SA
MCON
MC
OFFTHRX
THRX
TRXMC
TRXFLT-A FLT-B
R/L1 B1 B2
S/L2
T/L3U/T1
V/T2
W/T3
MCCB
MCCBPower supply
AC reactor VZ
R/L1U
V
W
X
Y
Z
S/L2
T/L3
Powersupply
VZ
DC reactor
R/L1
+1 +2
MCCB
S/L2
T/L3
V1000 15
Safety System
R/L1
S/L2
T/L3
S1 S2 S3 S4 S5 S6
-B1
+1+2
B2
U/T1
V/T2
W/T
3
24V
0V
SINK
SOUR
CE
MA
P1MB
MC
+24
V 8
mA
SC
P2 MP
AM ACPC IGR+
R-
S+ S-
H2RP
+V A1 A2 AC HCH1
DC re
acto
r V100
0
Gro
und
Anal
og o
utpu
t0
to +
10 V
DC
(2m
A)
Pulse
trai
nou
tput
Term
inal
resis
tanc
e#(1
20 W
, 1/2
W) RS
-485
/422
K1
K2K1
K1
K2
K2K1
aa
+-
K2
TH SA
A1A2
T11
T12
T31
T32
1323
3341
1424
3442
T21
T22
Cont
rol
Circ
uit
Star
t
Powe
r Su
pply
Brak
ing
resi
stor
Mul
ti-fu
nctio
n di
gita
l inpu
ts
MF
rela
y ou
tput MF
phot
o-co
uple
r ou
tput
DIP
switc
h S3
Shie
lded
gro
und
term
inal
Pulse
Inpu
t (m
ax. 3
2kHz
)An
alog
inpu
t PS
+10.
5 VD
C, m
ax. 2
0 m
AM
F An
alog
inpu
t 10
to 1
0 V
(20
kW)
MF
Anal
og in
put 2
0 to
10
V (2
0 kW
) or
0/4
to 2
0 m
A (2
50 W
)
Safe
Disa
ble
inpu
ts
V100
0 sa
fe s
top
appl
icat
ion
usin
g O
MR
ON
G9S
B sa
fety
rela
y un
it co
mpl
ies
to s
afet
yca
tego
ry 3
acc
ordi
ng E
N 95
4-1
/ Sto
p ca
tego
ry 0
acc
ordi
ng E
N60
204
Ensu
re V
1000
and
saf
ety
rela
y ar
e m
ount
ed in
the
sam
e ca
bine
t to
excl
ude
cros
sci
rcui
t bet
wee
n H1
and
H2
16 Frequency inverters
V1000
Ordering information
Specifications Model
Heavy Duty Normal Duty Standard Built-in filter
1x200 V
0.12 kW 0.8 A 0.18 kW 0.8 A VZAB0P1BAA VZAB0P1EAA
0.25 kW 1.6 A 0.37 kW 1.6 A VZAB0P2BAA VZAB0P2EAA
0.55 kW 3.0 A 0.75 kW 3.5 A VZAB0P4BAA VZAB0P4EAA
1.1 kW 5.0 A 1.1 kW 6.0 A VZAB0P7BAA VZAB0P7EAA
1.5 kW 8.0 A 2.2 kW 9.6 A VZAB1P5BAA VZAB1P5EAA
2.2 kW 11.0 A 3.0 kW 12.0 A VZAB2P2BAA VZAB2P2EAA
4.0 kW 17.5 A 5.5 kW 21.0 A VZAB4P0BAA -
3x200 V
0.12 kW 0.8 A 0.18 kW 0.8 A VZA20P1BAA -
0.25 kW 1.6 A 0.37 kW 1.6 A VZA20P2BAA -
0.55 kW 3.0 A 0.75 kW 3.5 A VZA20P4BAA -
1.1 kW 5.0 A 1.1 kW 6.0 A VZA20P7BAA -
1.5 kW 8.0 A 2.2 kW 9.6 A VZA21P5BAA -
2.2 kW 11.0 A 3.0 kW 12.0 A VZA22P2BAA -
4.0 kW 17.5 A 5.5 kW 21.0 A VZA24P0BAA -
5.5 kW 25.0 A 7.5 kW 30.0 A VZA25P5FAA -
7.5 kW 33.0 A 11.0 kW 40.0 A VZA27P5FAA -
11 kW 47.0 A 15.0 kW 56.0 A VZA2011FAA -
15 kW 60.0 A 18.5 kW 69.0 A VZA2015FAA -
3x400 V
0.37 kW 1.2 A 0.37 kW 1.2 A VZA40P2BAA VZA40P2EAA
0.55 kW 1.8 A 0.75 kW 2.1 A VZA40P4BAA VZA40P4EAA
1.1 kW 3.4 A 1.5 kW 4.1 A VZA40P7BAA VZA40P7EAA
1.5 kW 4.8 A 2.2 kW 5.4 A VZA41P5BAA VZA41P5EAA
2.2 kW 5.5 A 3.0 kW 6.9 A VZA42P2BAA VZA42P2EAA
3.0 kW 7.2 A 4.0 kW 8.8 A VZA43P0BAA VZA43P0EAA
4.0 kW 9.2 A 5.5 kW 11.1 A VZA44P0BAA VZA44P0EAA
5.5 kW 14.8 A 7.5 kW 17.5 A VZA45P5FAA -
7.5 kW 18.0 A 11.0 kW 23.0 A VZA47P5FAA -
11 kW 24.0 A 15.0 kW 31.0 A VZA4011FAA -
15 kW 31.0 A 18.5 kW 38.0 A VZA4015FAA -
C C
C C
D
E
F
A
B
C
A
A
C
Copy
Verify
Read
LOCK
YASKAWA
JVOP-181
USB Copy Unit
COMERR
LCD Remote Operator
MCCB
V1000
Filter
Input AC Reactor
Motor
Ground
Power Supply
CX-Drive CX-One
RJ-45 / USB Adapter
Remote Operator Extansion Cable
USB Cable
24VDC Control Board Power Supply
Communication Option Board
Braking Resistor
DC reactor
Mounting Accesories
Output AC Reactor
A
A
Choke
RS232 Communications cable with PC
V1000 17
A Line filters
A Input AC reactors
A DC reactors
InverterStandard line filter Low leakage line filter
Schaffner Rasmi Schaffner Rasmi
Voltage Model VZA@ ReferenceA1000-FIV Current (A) Reference
A1000-FIV Current (A) ReferenceA1000-FIV Current (A) Reference
A1000-FIV Current (A)
1-Phase200 VAC
B0P1 / B0P2 / B0P4 1010-SE 10 1010-RE 10 1010-SE-LL 10 1010-RE-LL 10
B0P7 / B1P5 1020-SE 20 1020-RE 20 1020-SE-LL 20 1020-RE-LL 20
B2P2 1030-SE 30 1030-RE 30 1030-SE-LL 24 1030-RE-LL 30
B4P0 1040-SE 40 1040-RE 40 1040-SE-LL 40 1040-RE-LL 40
3-Phase200 VAC
20P1 / 20P2 / 20P4 / 20P7 2010-SE 8 2010-RE 10 2010-SE-LL 10 2010-RE-LL 10
21P5 / 22P2 2020-SE 14 2020-RE 16 2020-SE-LL 20 2020-RE-LL 16
24P0 2030-SE 24 2030-RE 26 2030-SE-LL 30 2030-RE-LL 26
25P5 / 27P5 2060-SE 52 2060-RE 60 - - 2060-RE-LL 60
2011 2080-SE 68 2080-RE 80 - - 2080-RE-LL 80
2015 2100-SE 80 2100-RE 100 - - 2100-RE-LL 100
3-Phase400 VAC
40P2 / 40P4 3005-SE 5 3005-RE 5 3005-SE-LL 5 3005-RE-LL 5
40P7 / 41P5 / 42P2 / 43P0 3010-SE 10 3010-RE 10 3010-SE-LL 10 3010-RE-LL 10
44P0 3020-SE 15 3020-RE 15 3020-SE-LL 15 3020-RE-LL 15
45P5 / 47P5 3030-SE 30 3030-RE 30 3030-SE-LL 30 3030-RE-LL 30
4011 / 4015 3050-SE 50 3050-RE 50 3050-SE-LL 50 3050-RE-LL 50
Inverter AC Reactor
Voltage Model VZA@ Reference
1-Phase 200 VAC
B0P1 / B0P2 / B0P4 AX-RAI02000070-DE
B0P7 AX-RAI01700140-DE
B1P5 AX-RAI01200200-DE
B2P2 AX-RAI00630240-DE
B4P0 -
3-Phase 200 VAC
20P1 / 20P2 / 20P4 / 20P7 AX-RAI02800080-DE
21P5 / 22P2 / 24P0 AX-RAI00880200-DE
25P5 / 27P5 AX-RAI00350335-DE
2011 / 2015 AX-RAI00180670-DE
3-Phase 400 VAC
40P2 / 40P4 / 40P7 / 41P5 AX-RAI07700050-DE
42P2 / 43P0 / 44P0 AX-RAI03500100-DE
45P5 / 47P5 AX-RAI01300170-DE
4011 / 4015 AX-RAI00740335-DE
200V 1-phase 200V 3-phase 400V 3-phase
Model VZA@ DC Reactor Model VZA@ DC Reactor Model VZA@ DC Reactor
B0P1AX-RC10700032-DE
20P1AX-RC21400016-DE
40P2 / 40P4 AX-RC43000020-DE
B0P2 20P2 40P7 AX-RC27000030-DE
B0P4 AX-RC06750061-DE 20P4 AX-RC10700032-DE 41P5 AX-RC14000047-DE
B0P7 AX-RC03510093-DE 20P7 AX-RC06750061-DE 42P2 AX-RC10100069-DE
B1P5 AX-RC02510138-DE 21P5 AX-RC03510093-DE 43P0 AX-RC08250093-DE
B2P2 AX-RC01600223-DE 22P2 AX-RC02510138-DE 44P0 AX-RC06400116-DEB4P0 - 24P0 AX-RC01600223-DE 45P5 AX-RC04410167-DE
-
25P5 AX-RC01110309-DE 47P5 AX-RC03350219-DE
27P5 AX-RC00840437-DE 4011 AX-RC02330307-DE
2011 AX-RC00590614-DE 4015 AX-RC01750430-DE
2015 AX-RC00440859-DE -
18 Frequency inverters
A Chokes
A Output AC reactor
B Communication cards
C Accessories
D Computer software
Model Diameter Description
AX-FER2102-RE 21 For 2.2 KW motors or below
AX-FER2515-RE 25 For 15 KW motors or below
AX-FER5045-RE 50 For 45 KW motors or below
Inverter AC Reactor
Voltage Model VZA@ Reference
200 VAC
B0P1 / B0P2 / B0P420P1 / 20P2 / 20P4 AX-RAO11500026-DE
B0P7 / 20P7 AX-RAO07600042-DE
B1P5 / 21P5 AX-RAO04100075-DE
B2P2 / 22P2 AX-RAO03000105-DE
B4P0 / 24P0 AX-RAO01830160-DE
25P5 AX-RAO01150220-DE
27P5 AX-RAO00950320-DE
2011 AX-RAO00630430-DE
2015 AX-RAO00490640-DE
400 VAC
40P2 / 40P4 / 40P7 / 41P5 AX-RAO16300038-DE
42P2 AX-RAO11800053-DE
43P0 / 44P0 AX-RAO07300080-DE
45P5 AX-RAO04600110-DE
47P5 AX-RAO03600160-DE
4011 AX-RAO02500220-DE
4015 AX-RAO02000320-DE
Type Model Description Function
Com
mun
icat
ion
optio
n bo
ard
SI-N3/V DeviceNet option card • Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through DeviceNet communication with the host controller.
SI-P3/V PROFIBUS-DP option card• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through PROFIBUS-DP communication with the host controller.
SI-S3/V CANopen option card• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through CANopen communication with the host controller.
SI-T3/V MECHATROLINK-II option card• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through MECHATROLINK-II communica-tion with the host controller.
SI-ES3/V EtherCAT option card• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through EtherCAT communication with the host controller.
SI-EP3/V PROFINET option card• Used for running or stopping the inverter, setting or referencing parameters, and monitoring
output frequency, output current, or similar items through PROFINET communication with the host controller.
Types Model Description Functions
Dig
ital
oper
ator JVOP-180 LCD remote operator LCD Display operator with language support
A1000-CAVOP300-EE Remote operator cable 3 meters cable for connecting remote operator
Acc
esso
ries
JVOP-181 USB converter / USB cable USB converter unit with copy and backup function
PS-V10S24 VDC option board
24VDC control board power supply VZA-B/2/4 from 0.1 to 4 KW
PS-V10M 24VDC control board power supply VZA-2/4 from 5.5 to 15 KW
A1000-CAVPC232-EE PC connection cable RS232 PC tool connection cable
Types Model Description Installation
Sof
twar
e CX-Drive Computer software Configuration and monitoring software tool
CX-One Computer software Configuration and monitoring software tool
V1000 19
E Braking unit, braking resistor unit
sssF Mounting accessories
Inverter Braking resistor unit
Voltage Max. motor kW
Inverter model VZA@Connectable min.
resistance
Inverter mounted type(3 %ED, 10 sec max) Braking
torque %1-phase 3-phase Type AX- Resist
200 V (single-/
three-phase)
0.12 B0P1 20P1300 REM00K1400-IE 400
135
0.25 B0P2 20P2 120
0.55 B0P4 20P4 200REM00K1200-IE 200
120
1.1 B0P7 20P7 120 70
1.5 B1P5 21P560 REM00K2070-IE 70
190
2.2 B2P2 22P2 120
4.0 B4P0 24P0 32
REM00K4035-IE 35
135
5.5 – 25P5 16 75
7.5 – 27P5
9.6
55
11 – 2011 REM00K6035-IE 35 40
15 – 2015 REM00K9017-IE 17 55
400 V(three-phase)
0.37 – 40P2750
2 x REM00K1400-IE 800
270
0.55 – 40P4 270
1.1 – 40P7 510 270
1.5 – 41P5 240 REM00K1400-IE 400 130
2.2 – 42P2 200 REM00K2200-IE 200 130
3.0 – 43P0100 REM00K2120-IE 120
215
4.0 – 44P0 160
5.5 – 45P532 REM00K4035-IE 35
140
7.5 – 47P5 80
11 – 401120
REM00K6035-IE 35 50
15 – 4015 REM00K9020-IE 20 55
Types Model Description Applicable models VZA@
DIN
Rai
l
EZZ08122A
Necessary to mount the inverter on a DIN rail
B0P1/B0P2/B0P420P1/20P2/20P4/20P7
EZZ08122BB0P7/B1P521P5/22P2
40P2/40P4/40P7/41P5/42P2
EZZ08122CB2P224P044P0
EZZ08122D B4P0
Hea
tsin
k ex
tern
al m
ount
ing
atta
chm
ent
100-034-075
Additional items to mount the inverter withthe heatshink out of the panel
B0P1/B0P220P1/20P2
100-034-076 B0P420P4
100-034-077 20P7
100-034-078 40P2
100-034-079B1P5
21P5/22P241P5/42P2/43P0
100-034-080B2P224P044P0
100-036-357 B4P0
100-036-418 B0P740P2/40P4
100-036-300 25P5/27P545P5/47P5
100-036-301 20114011/4015
100-036-302 2015
20 Frequency inverters
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. I68E-EN-03