HP2-T17

36
QUESTION: 1 Which processors use hyperthreading? (Select two.) A. Intel single core processors B. AMD dual core processors C. AMD quad core processors D. Inteldual core processors Answer: A,D QUESTION: 2 How many memory channels are there in a 2 processor DDR3-based server? A. 2 channels B. 3channels C. 4channels D. 6 channels Answer: D QUESTION: 3 On Intel Xeon 5500 Series (Nehalem) based servers, where is the memory controller located? A. processor socket B. processor core C. HyperTransport Bus D. Front Side Bus Answer: B QUESTION: 4 Which components are under the control of Dynamic Power Management on Intel Xeon 5500 Series (Nehalem) based servers? (Select two.) A. chipset HP2-T17

Transcript of HP2-T17

Page 1: HP2-T17

QUESTION: 1 Which processors use hyperthreading? (Select two.) A. Intel single core processors B. AMD dual core processors C. AMD quad core processors D. Inteldual core processors Answer: A,D QUESTION: 2 How many memory channels are there in a 2 processor DDR3-based server? A. 2 channels B. 3channels C. 4channels D. 6 channels Answer: D QUESTION: 3 On Intel Xeon 5500 Series (Nehalem) based servers, where is the memory controller located? A. processor socket B. processor core C. HyperTransport Bus D. Front Side Bus Answer: B QUESTION: 4 Which components are under the control of Dynamic Power Management on Intel Xeon 5500 Series (Nehalem) based servers? (Select two.) A. chipset

HP2-T17

2 http://www.hotcerts.com

Page 2: HP2-T17

B. PCI-e cards C. hard drives D. CPU E. fans Answer: A,D QUESTION: 5 A server has four disks, each 146GB in size. They are configured as RAID 5. What is the logical drive size presented to the operating system? A. 292GB B. 438GB C. 584GB D. 730GB Answer: B QUESTION: 6 Which operating system has support for the ZFS filesystem? A. Sun Solaris B. Windows Server 2008 R2x64 Enterprise Edition C. Novell NetWare 6.5 D. Novell SLES 10 Answer: A QUESTION: 7 Which type of internal slot has been added to HP ProLiant G6-based servers for use by hypervisors? A. Extreme Digital (xD) B. Secure Digital (SD) C. Compact Flash (CF) D. PCI-express (PCIe)

HP2-T17

3 http://www.hotcerts.com

Page 3: HP2-T17

Answer: B QUESTION: 8 For the Intel x5570Series processors in the HP ProLiant SL2x170z G6, what does the letter "x" preceding the processor model number indicate? A. extreme performance B. lowerwattage C. turbo boost performance D. highperformance/wattage Answer: D QUESTION: 9 In which log are Array POST errors recorded? A. Windows Event Log B. Integrated Management Log C. IPMI Log D. Onboard Administrator Log Answer: B QUESTION: 10 What information does the ADU provide? (Select three.) A. firmwareversion B. OEM hard drive vendor C. RAID stripe size D. HardwareErrorLogs E. SmartArray driver version Answer: A,C,D QUESTION: 11

HP2-T17

4 http://www.hotcerts.com

Page 4: HP2-T17

Which capability is a key improvement in HP ProLiant G6 servers using Dynamic Power Management? A. ability to spin down idle disk drives B. ability to put CPU sockets to sleep and wake up real time C. ability to power down unused PCI-e slots D. ability to put CPU cores to sleep and wake up real time Answer: D QUESTION: 12 What is required to support each installed HP 10Gbnetworkadapter in a ProLiantserver? A. dedicated 2GB RAM B. quad-core CPU C. QuickPath architecture D. internal PCI-X 2.0 Answer: A

QUESTION: 13 Which RAID level does Smart Array Advanced Pack (SAAP) employ to enhance performance, reliability and availability? A. RAID 1+0 B. RAID 5 C. RAID 6+0 D. RAID 5+0 Answer: C QUESTION: 14 Which key functions are under the control of the new ProLiant OnBoard Administrator found in every ProLiant G6 server? (Select two.)

HP2-T17

5 http://www.hotcerts.com

Page 5: HP2-T17

A. power and thermal optimization B. automated firmware upgrade C. extended health monitoring D. TPM module management Answer: A,C QUESTION: 15 A customerhas an HP ProLiant G6 server, which meets the minimum requirements of 4 disks. They have purchased the Smart Array Advanced Pack. The customercomplainsthat RAID 6isnot displayedas an option in ORCA. What must be done tocorrect the problem? A. The license key must be entered in RBSU. B. The license key must be activated over the Internet. C. The license key must be entered in ORCA. D. The license key must be entered iniLO RBSU. Answer: C QUESTION: 16 On ProLiant G6 servers, which statements are true about System Maintenance Utility? (Select two.) A. Array Diagnostic Utility is part of System Maintenance Menu options. B. Diagnostic Utility is not part of System Maintenance Menu options. C. You can run memory testsfrom System Maintenance Utility. D. Youcannotaccess RBSU through System Maintenance Menu Utility. E. Youcanaccess RBSU through System Maintenance Menu Utility. Answer: C,E QUESTION: 17 What is a function of the UPS management module? A. receivestraps from HPSIM B. sendsemailnotification messages

HP2-T17

6 http://www.hotcerts.com

Page 6: HP2-T17

C. manages thenumber and size of the text logs stored D. provides automatic voltage regulation Answer: B QUESTION: 18 The system board of a DL380 G6 Server has failed. What should be done with the Trusted Platform Module (TPM) that was installed and in use? A. The TPM needs to be reinitialized and then reinstalled onto the new motherboard. B. TPM firmware revisions must be synchronized with the system board. C. The TPM module must be replaced with the motherboard. D. The TPMmustbe reinstalled on the new motherboard after the new motherboard has been flashed to the most current BIOS. Answer: C QUESTION: 19 Which utilities can you use to change the bootable media sequence? (Select two.) A. System Maintenance Menu B. RBSU C. SMH D. OptionROMConfiguration forArrays E. Insight Diagnostic CD Answer: A,B QUESTION: 20 What is the minimum number of hard disks required for RAID 6? A. 2 B. 4 C. 6 D. 8

HP2-T17

7 http://www.hotcerts.com

Page 7: HP2-T17

Answer: B QUESTION: 21 You install a DL380 G6Server withsixdisks. Your customerwantsto have the maximum disk space available but still have protection against a disk failure. Which RAID level should you recommend? A. RAID 0 B. RAID 1 C. RAID 5 D. RAID 6 Answer: C QUESTION: 22 Which HP utilityshould you use to perform onlineRAIDmigration? A. iLO 2 B. ORCA C. ACU D. RBSU Answer: C QUESTION: 23 You install a DL380 G6Server withsixdisks. Your customerwantsmaximum protection against a disk failure. Which RAID level should you recommend to withstand two simultaneous drive failures in a single array? A. RAID 0 B. RAID 1 C. RAID 5 D. RAID 6 Answer: D

HP2-T17

8 http://www.hotcerts.com

Page 8: HP2-T17

QUESTION: 24 Your customer requiresacost-effective external storage solution with 20 hard drives fortheirDL380 G6Server. Whichsolution should yourecommend? A. HP Smart Array P411 and HPStorageWorks 70 Modular Smart Array B. HP Smart Array P410 and HPStorageWorks 70 Modular Smart Array C. HP Smart Array P800 and HPStorageWorks 50 Modular Smart Array D. HP SAS expander card and second internal drive cage Answer: A QUESTION: 25 What is used to adda hot spare drive toan array ona Smart Array 410iController? (Selecttwo.) A. ORCA B. ADU C. ACU D. SMU E. RBSU Answer: A,C QUESTION: 26 A complete power failureoccursduring asystemROM upgradeon a ProLiant DL380 G6. What happens when the server is restarted? A. The server continues using the original ROM version. B. The server stops during POST and prompts to continue the upgrade. C. The server must be reloaded with the original ROM version. D. The server restarts using theupdatedROM version. Answer: A QUESTION: 27 Your customer's server failed. You have followed the HPSixStepTroubleshootingMethodology and have determinedthatthe problem, a

HP2-T17

9 http://www.hotcerts.com

Page 9: HP2-T17

defective power supply, is fixed. You recommend to your customer that they install a redundant power supply to help prevent further downtimE. Whichstep of the HP Troubleshooting Methodology are youimplementing? A. Implement preventive measures B. Develop an action plan C. Evaluate data D. Execute an action plan Answer: A QUESTION: 28 Your customer's server has crashed and data was lost. You use the HP Six Step Troubleshooting Methodology to analyze and solve your customer's problem. Place the steps in the correct order.

Answer: Pending. Please email feedback to support team QUESTION: 29 What provides a view of server health information?

HP2-T17

10 http://www.hotcerts.com

Page 10: HP2-T17

A. ACU B. ADU C. SMH D. Firmware Maintenance CD Answer: C QUESTION: 30 Where do you access the IPMI Event Log on 100 Series servers? A. Integrated Management Log (IML) B. SmartStart CD C. RBSU D. HP Insight Diagnostics Answer: C QUESTION: 31 Where can you view hardware failure events in ProLiant 300/600/700 Series servers? A. Firmware Maintenance CD B. ORCA C. Integrated Management Log(IML) D. RBSU Answer: C QUESTION: 32 Beep codes are one of the first indications of a failure. What do they indicate? A. TheSmart Array has a failed disk. B. The redundantpowersupply has failed. C. The processor has unsupported wattage. D. The passive processorfanhas failed.

HP2-T17

11 http://www.hotcerts.com

Page 11: HP2-T17

Answer: C QUESTION: 33 What is a useful counter in the Processor category of Microsoft's Performance Monitor for evaluating the processor subsystem? A. % Processor Time B. %ProcesserTasks C. % CacheWrites D. %TagQueues Answer: A QUESTION: 34 When should a field engineer escalate a service call? A. after you have been onsite more thanone hour B. afterthreemajorhardwarecomponentshave been replacedandthe problem is unresolved C. when youcannotrun Insight Diagnostics D. when the current action plan does not meet the customer's expectations Answer: D QUESTION: 35 Youreplacedthe memory module inaProLiant server and the amber LED from Insight Display disappeared. You run an Insight Diagnostics Offline EditionUtility fromtheSmartStart CD and started the complete memory test. According to HPTroubleshootingMethodology, which stepdid you perform? A. Evaluatedata B. Determineif problem is solved C. Implement preventive measures D. Executethe action plan E. Collect data Answer: B

HP2-T17

12 http://www.hotcerts.com

Page 12: HP2-T17

QUESTION: 36 You just executed a step from your action plan.What is thenext stepyou should takeaccording to HPTroubleshootingMethodology? A. Collect data B. Determine if the problem is solved C. Implement preventive measures D. Evaluate data E. Develop an optimized action plan Answer: B QUESTION: 37 How canyou updatethe Version Control Repository Manager (VCRM)database?(Select two.) A. Manually updateitfromtheManagement DVD. B. Usethe Upload to VCRMfeature oftheVCRM Update CD. C. Manually download the software from the HP website into the repository. D. Manually copy updates fromtheSmartStart CD. E. UsetheRepository Auto Update feature inHPSIM. Answer: C,D QUESTION: 38 Which protocol enables block level storage data to be transported over IP networks? A. SCSI-3 B. iSCSI C. FCoE D. Etherchannel Answer: B

HP2-T17

13 http://www.hotcerts.com

Page 13: HP2-T17

QUESTION: 39 Which tool incorporates the ProLiant Integration module? A. HP Insight Rapid Deployment software (RDP) B. HP Insight Vulnerability and Patch Managermodule (VPM) C. HP Insight Performance Manager module (PMP) D. HP Insight Power Manager software (IPM) Answer: A QUESTION: 40 You use theADUstarted from the SmartStartCD. You want to send the result for further analysis. Wherecanyou save the file? A. on a CD, burnedwith the optional CD-burner B. on Drive C using NTFS C. on a USBstick D. on a mapped network drive using FAT16/32 Answer: C QUESTION: 41 What should you doto test system memory in a ProLiant server? (Select two.) A. Run HP Insight Diagnostics Utility (online), using the SMH. B. Run HP Insight Diagnostics Utility (offline), using the Maintain Server button when bootinga 8.x SmartStartCD. C. Run the HPIntegrated Management Log (IML) and choose it in the drop-down menu. D. Run the embedded Diagnostics Utility onProLiant servers equipped with 4MB ROM. Answer: B,D QUESTION: 42 What does the ProLiant DL160 G6 need for virtual media and virtual KVM? A. to buy an advanced license for theiLO2 fortheProLiant DL160 G6

HP2-T17

14 http://www.hotcerts.com

Page 14: HP2-T17

B. to update the LO100i with the advanced license C. nothing since the advancediLO2 license is included with this ProLiant DL160 G6 D. nothing since theProLiant DL160 G6already has those features available Answer: B QUESTION: 43 You are updating theBIOSof a ProLiant DL380 G6. The ProLiant is not protected by a UPS. During the update,the utility power isoffforoneminuteand the firmware update fails. What should you do after the utility powerreturns? A. You wait for theProLiant to boot. It will detect the corruptedROMand will switch to the backupROM. You can restart yourBIOSupdate. B. You replace the systemboard and restart theBIOSupdate. C. You do a system erase from theSmartStart CD and restart theBIOSupdate. D. You start the System Configuration Utility, type Control-A for advanced mode and do a manualBIOSrecovery.You thenrestart theBIOSupdate. Answer: A QUESTION: 44 What can cause an upgrade of the ProLiant Support Pack on a ProLiant server running Microsoft Windows Server 2008 to fail? A. An installed hardware component has the Write Protect feature turned on. B. The PSPusedwas forHP-UX andis not compatible with Microsoft Windows Server. C. Microsoft Windows Server 2008 does not support upgrading PSP but requires a full new installation of PSP. D. An installed hardware component is not supported by Microsoft or by HP. Answer: D QUESTION: 45 In a support case you have to escalate a problem to the HP Support team. They expect a problem with some out-of-date drivers. What should you do to create a file that can be used to show them the currently installed versions?

HP2-T17

15 http://www.hotcerts.com

Page 15: HP2-T17

A. Start SurveyUtility fromtheHPSmartStartCD. B. Start SurveyUtility from within theOnline Insight DiagnosticsEdition. C. Start Inspect Utility fromtheServer StartupCD. D. StartEmbedded Inspect Utility onProLiants equipped with a 4MB ROM using RBSU. Answer: B QUESTION: 46 An administrator cannot log in to iLO 2 using his previously working account. What can solve this login problem? A. Reset the systems settings in RBSU. B. Use the System EraseUtility to selectively erase theiLO password. C. Engage theiLO 2 Security Override Switch procedure. D. Boot the system with theSmartStart CD and select "Reset Passwords." Answer: C QUESTION: 47 You install 16 new 4GB Memory DIMMs on a single processor DL385 G6 that is running Windows 2003 x64 Enterprise Edition. The system only sees 32GB of memory. What is the possible reason? A. Firmware must be updated tothelatest version to support 64GBmemory. B. DIMM banks are only active when the corresponding processor socket is populated. C. Windows 2003/2008 x64Enterprise Edition must be installed to support more than 32GB ofmemory. D. Youmustactivatethe"Use Memory above 32GB" option in the RBSU. Answer: B QUESTION: 48 What is the common warranty for ProLiant 300 Series servers? A. 1yearparts, 1year labor, 1yearonsitesupport B. 3 years parts, 3 years labor, 3 years onsite support C. 1 year parts, 1 year labor, 0 year onsite support

HP2-T17

16 http://www.hotcerts.com

Page 16: HP2-T17

D. 3 years parts, 3 years labor, 0 year onsite support Answer: B QUESTION: 49 You have a customer that wants support that includes software technical assistance and 4-hour hardware response time. Which service provides this? A. Proactive 24 B. 4-hour 24x7 Same Day C. 4-hour Same Business Day D. HP Support Plus Answer: A QUESTION: 50 What does Proactive 24 Service offer customers? A. Proactive Reporting for predictive failures B. pre-failure hardware services C. 7x24 warranty coverage D. 2-hour software and4-houronsite Answer: D QUESTION: 51 What is the primary purpose of a control bus? A. connects high-speed internal and external I/O devices to the I/O controller hub B. connects I/O ports, expansion I/O controllers, and expansion slots to the I/O controller hub C. moves instructions for the microprocessor or information the microprocessor is transmitting D. carries signals that indicate the target and purpose of the data transfer Answer: D

HP2-T17

17 http://www.hotcerts.com

Page 17: HP2-T17

QUESTION: 52 Which RAID level provides fast read access and slower write performance? A. RAID 0 B. RAID 1 C. RAID 1+0 D. RAID 5 Answer: D QUESTION: 53 Which hard disk drive interface types, used in HP ProLiant servers, are supported on the same system backplane? (Select two.) A. ATA B. FC-AL C. SCSI D. SATA E. SAS Answer: D,E QUESTION: 54 The HP ProLiant 100Seriesoffers which auto-recovery feature? A. ASR B. Watchdog Timer C. TPM D. BIOS Serial Console Answer: B QUESTION: 55 What are features of the Server Board Management Controller found in HP ProLiant 100 Series servers? (Select two.)

HP2-T17

18 http://www.hotcerts.com

Page 18: HP2-T17

A. remote BIOS checking/switching functionality B. remote console access C. remote alerting D. virtual media access E. integrated remote console Answer: A,C QUESTION: 56 How can you access an iLO 2 when you do not know the user ID and password? A. Enable theiLO 2 Security Override switch on the front of the server. B. Enable theiLO 2 Security Override switch inside the server. C. Press and hold the NMI button during POST. D. Utilize the URL https://<iLOIPaddress>/fieldservice. Answer: B QUESTION: 57 Which advantages do Power Distribution Units offer? (Select two.) A. active voltage regulation B. increasedinput power C. easy accessibility to outlets D. superior cable management Answer: C,D QUESTION: 58 What is the minimum cache sizerequiredto enable Smart Array Advanced Pack (SAAP)? A. 128MB B. 64MB C. 512MB D. 256MB

HP2-T17

19 http://www.hotcerts.com

Page 19: HP2-T17

Answer: D QUESTION: 59 Which HPtools are used to manage ROMPaqs onProLiantML/DL servers? (Select two.) A. Insight Diagnostics B. HP Smart Update Manager (SUM) C. Virtual Connect Enterprise Manager(VCEM) D. Rapid Deployment Pack(RDP) E. Array Diagnostic Utility(ADU) Answer: B,D QUESTION: 60 Using the HP ProLiant Essentials Performance Management Pack (PMP), when should you capture a performance baseline for an HP ProLiant server? (Select two.) A. every 90 days B. after any hardware or software updates C. at the end of each month D. during peak monthly business cycles E. after initial installation of the equipment F. after each systemreboot Answer: B,E QUESTION: 61 Whichsafetyguidelines shouldyou observe when installing a rack? (Select two.) A. Remove the grounding wire on the receptacleof the UPS to assure isolated grounding. B. Couple racks together on multiple-rack configurations. C. Levelthe front feetonlyto allow the rack to be moved if needed. D. Deploy stabilizingfeet only when you have multiple servers extended from the rack. E. Distribute weight properly and install ballast kits if necessary. Answer: B,E

HP2-T17

20 http://www.hotcerts.com

Page 20: HP2-T17

QUESTION: 62 What is the correct function key to press to access RBSU directly during POST on a DL360 G6? A. F2 B. F8 C. F9 D. F10 E. F12 Answer: C QUESTION: 63 On an HP ProLiant G6 server, which statements are true about RBSU and System Maintenance Menu? (Select two.) A. You pressF10 to access the System Maintenance Menuand accessRBSU . B. RBSU helpsconfigure server hardware settings and run basic diagnosticsfor the server hardware. C. The server serial numbercan be updatedthrough RBSU. D. TheADUcan be runfrom System Maintenance Menu. E. Memory testscan be runfrom RBSU. Answer: A,C QUESTION: 64 What is the maximum number of unbuffered DIMMs (UDIMMs) per channel supported in a ProLiant G6 Server? A. 1 B. 2 C. 3 D. 4 Answer: B

HP2-T17

21 http://www.hotcerts.com

Page 21: HP2-T17

QUESTION: 65 Your customer has a DL380 G6 Server with one processor and nine 4GB Registered DIMMs (RDIMMs) installed. You add nine additional 4GB RDIMMs in the remaining memory slots. What else must you do to make the newly installed memory available to the system? A. Enable memory mirroring in RBSU. B. Add a second processor. C. Replace the RDIMMs withUnbuffered DIMMS (UDIMMs). D. Update the systemROM. Answer: B QUESTION: 66 You are installingfivedrives into an MSA70.You want to maximize the amount of storage and still provide data protection.WhichRAIDlevelshould you choose? A. RAID 0 +1 B. RAID 0 C. RAID 1 D. RAID 5 E. RAID 6 Answer: D QUESTION: 67 Your customer has asked for fiber-based shared storage.Whichproduct should you recommend? A. MSA 70 B. MSA 2000i C. MSA 2000sa D. MSA 2000fc Answer: D QUESTION: 68

HP2-T17

22 http://www.hotcerts.com

Page 22: HP2-T17

Which cable should be used for connecting HP Smart Array P411 to HP StorageWorks 70 Modular Smart Array? A. Mini SAS 4x cable B. VHDCI/VHDCI SCSI Cable C. Cat5e Patch Cable D. LC-LC multi-modeFibre Channel cable Answer: A QUESTION: 69 A customer wants a second Smart ArrayController installed in a DL380 G6 and will be booting from it. Where do you select the option tomodify boot controller order?(Select two.) A. RBSU B. ORCA C. ACU D. ADU Answer: A,B QUESTION: 70 Which action is part of Step 1- Gather Informationof the HP Troubleshooting Methodology? A. replacea defective memory module B. recommend to the customer they use Advanced ECC memory C. remove the memory modulesoneat a time until the error stops D. examinethe failure condition from LED indicators Answer: D QUESTION: 71 Where can you view ROM POST error codes?

HP2-T17

23 http://www.hotcerts.com

Page 23: HP2-T17

A. Integrated Management Log (IML) B. ADU C. Event Viewer D. System Insight Display Answer: A QUESTION: 72 Which ProLiant server series includes the Watchdog Timer? A. 100Series B. 300Series C. 500Series D. 700Series Answer: A QUESTION: 73 What are useful counters in the Memory category of Microsoft's Performance Monitor? (Select two.) A. Memory Refresh Rate B. Memory RAID performance C. Pages/Sec D. available Bytes (kilobytes or megabytes) Answer: C,D QUESTION: 74 What can you do to optimize disk I/O per second in a random I/O environment? (Select two.) A. Add ahotspare disk drive. B. Add more spindles. C. Add more memory. D. Add disks with faster rotational speed.

HP2-T17

24 http://www.hotcerts.com

Page 24: HP2-T17

E. Add more processors Answer: B,D QUESTION: 75 What are some common reasons for unexpected server reboots? (Select two.) A. TheSmartStartCDwasleft in the CDdrive. B. Newly added hardware caused a memory conflict. C. There is an issue with operating system, application and device drivers. D. You pressedCTRL + ALT + DEL. Answer: B,C QUESTION: 76 You are following an action plan that requires the replacement of a NIC. You replace the NIC and run the HP Insight Diagnostics.The NIC fails the test. WhichHP TroubleshootingMethodology step have you justperformed? A. Evaluate the data B. Determineproblem resolution C. Develop an action plan D. Collect data Answer: B QUESTION: 77 After replacing a failed DIMM, you run the HP Insight Diagnostics. The diagnostics complete without error. WhichHP TroubleshootingMethodology step have you completed? A. Determine problem resolution B. Execute the action plan C. Develop and action plan D. Evaluate the data

HP2-T17

25 http://www.hotcerts.com

Page 25: HP2-T17

Answer: A QUESTION: 78 What doestheVersion Control Agent (VCA)enable the customer to do?(Select three.) A. configure the log to automatically delete older entries, reducing maintenance activity for administrators B. configure the VCA to automatically download new firmware and software updates C. configure the VCA to automatically install new software updates D. view whether any applicable updates are available in the Version Control Repository Manager E. configure the VCA to automatically install new firmware updates F. view the currently installed firmware and drivers Answer: A,D,F QUESTION: 79 What detects, analyzes and explains hardware performance bottlenecks? A. HP Insight Virtual Machine Manager software (VMM) B. HP Insight Power Manager software (IPM) C. HP Insight Vulnerability and Patch Managermodule (VPM) D. HP Insight Performance Manager module (PMP) Answer: D QUESTION: 80 Which tool provides a server deployment solution that facilitates the installation of large numbers of servers? A. HP Insight Power Manager software (IPM) B. HP Insight Virtual Machine Manager software (VMM) C. HP Insight Rapid Deployment software (RDP) D. HP Insight Vulnerability and Patch Managermodule (VPM) Answer: C

HP2-T17

26 http://www.hotcerts.com

Page 26: HP2-T17

QUESTION: 81 A customer wants to reinstall a ProLiant G6Server. He createsa backup of all relevant data. Whatare the best waysto set NVRAM to factory default and clean up boot-drives? (Select two.) A. Go to RBSU -> Advanced Options and chooseErase NVRAM/Boot Disk. B. Run the System Erase Utility within the Windows OS. C. Power down,disconnectall power cords and take outthesystem battery for 5 minutes. D. Run the System Erase Utility fromtheSmartStart CD. Answer: A,D QUESTION: 82 How do you update the firmwareon an HP Server Console Switch (KVM)? A. Boot an attached server with theProLiantFirmware CD connected to the serial port of the KVM. B. Executethefirmware utility on a Windows system connected to the serial port of the KVM. C. Executethefirmware utility using a bootable USB stick. D. Use the HP Console Viewer and select theFirmwareUpdate button. Answer: B QUESTION: 83 Which memory protection features corrects both multibit errors and full DRAM failures? A. Error Checking and Correction (ECC) B. RAID Memory C. Advanced ECC (AECC) D. Online Spare Memory Answer: B QUESTION: 84

HP2-T17

27 http://www.hotcerts.com

Page 27: HP2-T17

Which deployment tool allows you to build a job that will flash the system and option ROMs? A. Service Essentials Remote Support Pack B. Insight Diagnostics C. SMH D. SmartStart Scripting Toolkit Answer: D QUESTION: 85 You need to do an online firmware update under Windows 2003 of a ProLiant Server. Which tools can you use? (Select two.) A. HPSUM from the Firmware Maintenance CD B. maintenance tool from theSmartStart CD C. Online HP Diagnostics D. Online ROM flash components E. OnlineROM-based Inspect Utility F. OnlineROMPaq diskette Answer: A,D QUESTION: 86 A customer purchased HP Care Pack services for HP ProLiant c-Class server blades. Which components are covered under the Care Pack? (Select two.) A. powersupply B. Fibre Host Bus Adaptor C. Ethernet Pass-Thru Module D. c-Classfans E. Array Controller Answer: B,E QUESTION: 87

HP2-T17

28 http://www.hotcerts.com

Page 28: HP2-T17

A customer wants a service that offers a two-hour response time for software issues and four-hour onsite response commitment for hardware issue resolution. Which service meets these requirements? A. 4-hour 24x7SameDay B. Proactive 24 C. 4-hourSameBusinessDay D. HP Support Plus Answer: B QUESTION: 88 Which memory protection mechanism was introduced with DDR3 memory modules? A. Memory Mirroring B. Advanced ECC C. Address Parity Detection D. Advanced Memory Buffer Answer: D QUESTION: 89 In the AMD Opteron architecture, each processor has access to the system RAM through which interface? A. Front Side Bus B. dedicated memory controllers C. processor chipset D. a common memory controller Answer: B QUESTION: 90 What are advantages of RAID 6 over RAID 5? A. better fault tolerance

HP2-T17

29 http://www.hotcerts.com

Page 29: HP2-T17

B. lower cost C. higherwrite performance D. double read performance Answer: A QUESTION: 91 Which HP ProLiant Server family series has replaced ASR with the WatchdogTimer? A. 100Series B. 300Series C. 500Series D. 700Series Answer: A QUESTION: 92 What can be usedtorestartthe remote management processor? (Select two.) A. iLO 2 RBSU (F8) B. Server andiLO 2 Diagnostics Page C. RBSU (F9) D. Telnet Session E. HPSMH Answer: A,E QUESTION: 93 Your customer wants end-to-end redundancy for a direct attached storage solution. Which combination of components will provide this level of availability? A. MSA 60, Smart Array E500, Dual Ported HDDs B. MSA 60, Smart Array P411, Dual Ported HDDs C. MSA 70, Smart Array P411, Dual Ported HDDs D. MSA 70, Smart Array P800, Dual Ported HDDs

HP2-T17

30 http://www.hotcerts.com

Page 30: HP2-T17

Answer: D QUESTION: 94 Which function key is used to access the System Maintenance Menu on a ProLiant DL380 G6? A. F2 B. F8 C. F9 D. F10 E. F12 Answer: D QUESTION: 95 You are upgrading the system ROM on a DL380 G6 Server with a Trusted Platform Module (TPM) installed and active. The server operating system is Windows 2008 with Bitlocker enabled. What does Microsoft recommend you do before flashing the system ROM? A. Enable maintenance mode on the TPM. B. Temporarily disable the TPM while updating the systemROM. C. Temporarily disableBitlocker while updating the system ROM. D. Restart the server in recovery mode,then perform the system ROM. Answer: C QUESTION: 96 Which statement is true about ORCA? A. ORCA configuresthe array automatically regardlessofthe number of hard drives connected toSmartArrayController. B. It supports drive expansion. C. It is available in English and Japanese. D. You run ORCA manually to configure the array when it has more than six drives connected toSmartArrayController

HP2-T17

31 http://www.hotcerts.com

Page 31: HP2-T17

Answer: D QUESTION: 97 How do you recover from a failed system ROM upgrade? A. Insertthe FirmwareCD and recover. B. Replace the system board. C. Restart the server to switch back to the previous BIOS throughtheredundant ROM option. D. Clear the NVRAM using the dipswitch 6 on the system board Answer: C QUESTION: 98 A customerwantsto connecteightservers to shared storage,but not invest inFibreChannel technology.Whichstorage optionshouldyourecommendto provide shared storage using the customer's existingEthernet infrastructure? A. MSA 50 B. MSA 2000i C. MSA 70 D. MSA 2000fc E. MSA 2000sa Answer: B QUESTION: 99 Whichkey is used to initially configureiLO2 settings? A. F8 B. F9 C. F10 D. F12 Answer: A

HP2-T17

32 http://www.hotcerts.com

Page 32: HP2-T17

QUESTION: 100 From where can you access the Survey Utility? A. C:\HP\Survey B. ACU C. RBSU D. HP Insight Diagnostics Answer: D QUESTION: 101 When evaluating the memory subsystem, the Pages/Sec counter is higher than what is acceptable. What should you do to rectify this situation? A. Use anonlinespare memory. B. Use memory RAID. C. Use disk drives with a faster transfer rate to keep up with memory. D. Add more memory. Answer: D QUESTION: 102 What is a useful counter in the Processor category of Microsoft's Performance Monitor for evaluating the processor subsystem? A. %TemperatureChange B. %Memory read to write ratio C. % Interrupt Time D. %CacheCounters Answer: C QUESTION: 103 What do beep codes for boot process failures indicate? (Select two.) A. ROM programmed incorrectly

HP2-T17

33 http://www.hotcerts.com

Page 33: HP2-T17

B. hotsparediskthat isnot present C. NIC Teaming failure D. video resolutionset too high E. mixed processor speeds detected Answer: A,E QUESTION: 104 A server shuts down after having been up for a short period of time. What is a possible cause of this problem? A. The system ROM is outdated. B. Heat sink is not properly installed. C. No video monitorisinstalled. D. The AC cord on a redundant power supply is loose or unplugged. Answer: B QUESTION: 105 Howisthe Version Control Repository Manager (VCRM)databaseupdated?(Select two.) A. by manually downloadingthe software from the Microsoft website into the repository B. by using the "Upload to VCRM" feature oftheSmartStart CD C. by manually updating itfromtheManagement DVD D. by using the automatic update feature of the VCR E. by using the"Repository Auto Update" feature inHPSIM Answer: B,D QUESTION: 106 Which account can you use by default to log in the HP SMH on a server running Windows 2003 with a PSP 7.20 or later? A. the user you created during the installation of the HP SMH B. all accounts within the domain belonging to the management group C. all accounts belonging to the local administrator'sgroup D. only the user"Administrator"belonging to theadministrator'sgroup

HP2-T17

34 http://www.hotcerts.com

Page 34: HP2-T17

Answer: C QUESTION: 107 What provides easy identification of virtual machines or host servers reaching high CPU utilization? A. HP Insight Power Manager software (IPM) B. HP Insight Vulnerability and Patch Managermodule (VPM) C. HP Insight Virtual Machine Manager software (VMM) D. HP Insight Performance Manager module (PMP) Answer: C QUESTION: 108 Both your primary and backup ROM of a ProLiant DL360 G6 has been corrupted. What is the best way to get the ProLiant back online? A. Apply the system ROM recovery procedure. B. Replace thesystem boardand update theBIOS. C. Reboot theProLiant.It will switch to the backupROMand update theBIOS. D. Use the recovery console to update the primary and the backupROM. Answer: A QUESTION: 109 The setup of a ProLiant DL180 G6 with the SmartStart CD failed. What could be a possible reason for this? A. SmartStart does not support the 100Series ProLiant servers. Server Startup must be used instead. B. TheiLO 2 "Protect OS" feature is turned on. C. Smart ArrayController is not initialized properly. Pressing F8 at POST could fix this problem. D. The BIOS "Protect OS" feature is turned on.

HP2-T17

35 http://www.hotcerts.com

Page 35: HP2-T17

Answer: A QUESTION: 110 What should you do first beforeupgradinga ProLiant to newer and faster CPUs? A. Install fasterDIMMs. B. Install more memory. C. Run the RBSU and do a system erase. D. Update the BIOS to the latest level. E. Start RBSU,go to the advanced menu,and fill in the new type of CPUs in the CPU menu. Answer: D QUESTION: 111 Which hardware types does HP Pre-failure Warranty cover? (Select two.) A. HostBusAdapters B. CD/DVD drives C. processors D. SCSI drives E. server backplanes Answer: C,D QUESTION: 112 DRAG DROP

HP2-T17

36 http://www.hotcerts.com

Page 36: HP2-T17

Answer: Pending. Please email feedback to support team

HP2-T17

37 http://www.hotcerts.com