HP StorageWorks 70 Modular Smart Array - Models

19
The HP StorageWorks 70 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting 2.5 inch SAS or Serial ATA (SATA) drives. This enclosure delivers industry-leading data performance, availability, storage density, and upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to support 2.5 inch Universal SAS and SATA hard drive form factors. The MSA70 enclosure supports direct attach storage (DAS) to HP ProLiant and Integrity Servers. The MSA70 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 50 drives in a 4U configuration behind each of the two external ports on the HP Smart Array P800, the HP Smart Array E500, the HP Smart Array P411, the HP Smart Array P212 or the P812 Controller for a total of 100 drives in 4 enclosures (a single controller port incorporates four lanes for a total max throughput of 12Gb/s for SAS). (NOTE: NOTE: NOTE: NOTE: Smart Array P411 and P812 Controllers are supported on ProLiant servers only). On HP ProLiant servers Dual Domain support is available for the HP Smart Array P800 attached to a MSA70 with the addition of the HP StorageWorks Dual Domain I/O Module Option (AG779A). (Single initiator environment only.) The MSA70 also supports the HP Smart Array P600 and the HP Smart Array P212 Controllers. Behind the single external port on the HP Smart Array P600 controller 1+1 cascading allows a maximum of 50 drives in a 4U configuration. (NOTE: NOTE: NOTE: NOTE: Smart Array P212 Controller is supported on ProLiant servers only). For HP-UX and Open VMS environments on selected HP Integrity Servers the MSA70 supports the HP (AH303A) SC44Ge Host Bus Adapter with the addition of the HP StorageWorks Dual Domain I/O Module Option (AG779A). Behind the single external port on the HP (AH303A) SC44Ge Host Bus Adapter 1+1 cascading allows a maximum of 50 drives in a 4U configuration. The HP (AH303A) SC44Ge Host Bust Adapter will only support HP-UX and Open VMS environments and will be available on all rack mounted HP Integrity Servers with PCIe slots. The addition of the I/O Module with the HP SC44Ge Host Bus Adapter adds support for Multi Initiator JBOD Clusters. It will support HP-UX and Open VMS on selected HP Integrity servers only. The MSA70 with the I/O Module and the HP SC44Ge Host Bus Adaptor will not support ProLiant servers. Multi Initiator JBOD clusters are supported with dual port SAS drives only. Support for HP Serviceguard software on HP-UX with HP-UX 11iv2/11iv3 only. HP Serviceguard monitors the health of each node and rapidly responds to failures in a way that minimizes or eliminates application downtime. NOTE: NOTE: NOTE: NOTE: HP Integrity servers that are supported: rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards) The MSA70 is also supported when attached to a HP StorageWorks 2324fc,sa & i Dual Controller Modular Smart Arrays. The MSA2324fc is a 4Gb Fibre Channel, the MSA2324sa a 3Gb SAS and the MSA2324i is a 1GbE connected 2U storage area network (SAN) or direct connect solutions that can accommodate twenty four (24) Small Form Factor (SFF) drives and are designed for small to medium size departments or remote locations. The MSA2324fc,s and i support attachment of up to three (3) dual I/O MSA70 SFF JBODs (99 SFF drives) What's New What's New What's New What's New Introducing support for new HP Smart Array Controller for the MSA70 with ProLiant servers HP Smart Array P812 Controller/1G Flash Backed Cache Controller QuickSpecs HP StorageWorks 70 Modular Smart Array HP StorageWorks 70 Modular Smart Array HP StorageWorks 70 Modular Smart Array HP StorageWorks 70 Modular Smart Array Overview DA - 12652 North America — Version 33 — July 30, 2010 Page 1

description

NA

Transcript of HP StorageWorks 70 Modular Smart Array - Models

 The HP StorageWorks 70 Modular Smart Array enclosure is a 2U Serial Attach SCSI (SAS) disk drive storage enclosure supporting2.5 inch SAS or Serial ATA (SATA) drives. This enclosure delivers industry-leading data performance, availability, storage density,and upgradeability to meet customers' demanding and growing storage needs. This enclosure is designed to support 2.5 inchUniversal SAS and SATA hard drive form factors. The MSA70 enclosure supports direct attach storage (DAS) to HP ProLiant andIntegrity Servers. The MSA70 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 50 drives in a 4Uconfiguration behind each of the two external ports on the HP Smart Array P800, the HP Smart Array E500, the HP Smart ArrayP411, the HP Smart Array P212 or the P812 Controller for a total of 100 drives in 4 enclosures (a single controller port incorporatesfour lanes for a total max throughput of 12Gb/s for SAS). (NOTE:NOTE:NOTE:NOTE: Smart Array P411 and P812 Controllers are supported onProLiant servers only).

On HP ProLiant servers Dual Domain support is available for the HP Smart Array P800 attached to a MSA70 with the addition of theHP StorageWorks Dual Domain I/O Module Option (AG779A). (Single initiator environment only.)The MSA70 also supports the HP Smart Array P600 and the HP Smart Array P212 Controllers. Behind the single external port on theHP Smart Array P600 controller 1+1 cascading allows a maximum of 50 drives in a 4U configuration. (NOTE:NOTE:NOTE:NOTE: Smart Array P212Controller is supported on ProLiant servers only).

For HP-UX and Open VMS environments on selected HP Integrity Servers the MSA70 supports the HP (AH303A) SC44Ge Host BusAdapter with the addition of the HP StorageWorks Dual Domain I/O Module Option (AG779A). Behind the single external port onthe HP (AH303A) SC44Ge Host Bus Adapter 1+1 cascading allows a maximum of 50 drives in a 4U configuration. The HP(AH303A) SC44Ge Host Bust Adapter will only support HP-UX and Open VMS environments and will be available on all rackmounted HP Integrity Servers with PCIe slots.

The addition of the I/O Module with the HP SC44Ge Host Bus Adapter adds support for Multi Initiator JBOD Clusters. It will supportHP-UX and Open VMS on selected HP Integrity servers only. The MSA70 with the I/O Module and the HP SC44Ge Host BusAdaptor will not support ProLiant servers. Multi Initiator JBOD clusters are supported with dual port SAS drives only.

Support for HP Serviceguard software on HP-UX with HP-UX 11iv2/11iv3 only. HP Serviceguard monitors the health of each nodeand rapidly responds to failures in a way that minimizes or eliminates application downtime.

NOTE:NOTE:NOTE:NOTE: HP Integrity servers that are supported:rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards)

The MSA70 is also supported when attached to a HP StorageWorks 2324fc,sa & i Dual Controller Modular Smart Arrays. TheMSA2324fc is a 4Gb Fibre Channel, the MSA2324sa a 3Gb SAS and the MSA2324i is a 1GbE connected 2U storage area network(SAN) or direct connect solutions that can accommodate twenty four (24) Small Form Factor (SFF) drives and are designed for smallto medium size departments or remote locations. The MSA2324fc,s and i support attachment of up to three (3) dual I/O MSA70 SFFJBODs (99 SFF drives)

What's NewWhat's NewWhat's NewWhat's NewIntroducing support for new HP Smart Array Controller for the MSA70 with ProLiant servers

HP Smart Array P812 Controller/1G Flash Backed Cache Controller

 

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Overview

DA - 12652   North America — Version 33 — July 30, 2010 Page 1

 

 Front panel LEDs and buttonsFront panel LEDs and buttonsFront panel LEDs and buttonsFront panel LEDs and buttons1. Status LED2. Fault LED3. UID button/LED

 

 Rear Panel componentsRear Panel componentsRear Panel componentsRear Panel components1. Power supply 1 6. I/O module bay2. Fan module 1 7. I/O module bay3. 7- segment display board 8. Fan module 24. SAS in connector 9. Power supply 25. SAS out connector

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Overview

DA - 12652   North America — Version 33 — July 30, 2010 Page 2

At A GlanceAt A GlanceAt A GlanceAt A Glance3G SAS host connectivityDual Domain support with HP Smart Array P800 Controller for HP ProLiant and Integrity servers (requires dual port SASdrives) (single environment only)Multi Initiator support with the SC44Ge Host Bus Adapter (AH303A) (HP-UX and Open VMS on selected HP Integrity Servers)with dual port SAS drives onlySupports twenty five 2.5 inch hot pluggable drivesSupports HP 6G SAS Dual-port disk drives, (300 GB, 450 GB & 600 GB capacities)Supports HP 6G SAS Dual-port Midline (MDL) disk drives (500 GB capacity)Supports HP SATA 3G disk drives, (250 & 500 GB capacities)Maximum storage capacity of 7.5 TB (with twenty five 300 GB 3G DP SAS), 12.5 TB (with twenty five 500 GB 6G SAS DPMDL) or 12.5 TB (with twenty five HP SATA 3G 500 GB hard drives)Attached to Smart Array P800, the Smart Array E500, the HP Smart Array P600, the HP Smart Array P411, the HP SmartArray P212 or the HP Smart Array P812 Controllers for HP ProLiant and Integrity Servers. (NOTE:NOTE:NOTE:NOTE: Smart Array P411, P212 &P812 Controllers are supported on ProLiant servers only).Attached to HP SC44Ge Host Bus Adapter for HP-UX and Open VMs support on selected HP Integrity Servers (servers thatsupport PCI-e cards)Supports attachment of up to three (3) dual I/O MSA70 behind a MSA2324fc (99 SFF drives for a total of 29.7TB SAS or24.7TB SATA) (NOTE: MSA70 is NOT supported behind a MSA2312fc (LFF)) (MSA2000 G2 Arrays not yet qualified with the500 GB SATA MDL drives).Supports MS Windows 2003, Microsoft Windows 2008, Red Hat Linux, SUSE Linux, VMware,Novell NetWare, HP-UX 11iv2 and 11iv3, Open VMS 8.3 1H1+1 Cascade support (behind a single SAS port)Supports boot from storageRedundant hot-plug power supplies and fans standardAddition of second I/O Module adds Dual Domain capability providing higher level of redundancy and reliability

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Overview

DA - 12652   North America — Version 33 — July 30, 2010 Page 3

Modular Smart ArrayModular Smart ArrayModular Smart ArrayModular Smart ArrayFamilyFamilyFamilyFamily

The HP StorageWorks Modular Smart Array family delivers simple, affordable storage technology tomeet today's demanding and growing IT needs. These storage solutions offer the best price/performanceand best price/availability features for direct attach environments, small clusters, workgroups and entry-level SAN environments. Each solution is designed to be easy to deploy, secure, and reducemanagement costs, while driving rapid return on investment.

Modular Smart Array 70Modular Smart Array 70Modular Smart Array 70Modular Smart Array 70 The HP StorageWorks 70 Modular Smart Array is an end-to-end flexible storage array, offering dataavailability, enhanced reliability, enhanced performance and tiered storage capability with SAS andSATA drives and investment protection.

Manage your small and midrange business growing storage needs by deploying this low cost, flexibletiered storage system with up to 30 TB SAS, 50 TB SAS MDL or 50 TB SATA (100 drives across fourenclosures) capacity supporting both SAS and SATA. The modular, scalable design of the MSA70provides a flexible platform allowing you to buy what is needed today and purchase additional capacityas data storage needs grow, instead of making a large up-front investment. Additional drives andenclosures can be easily added as customer needs dictate without extra management charges as needsgrow. For Small businesses, it is a stepping stone to simplify capacity expansion of HP ProLiant and HPIntegrity Server environments to external storage without having to make the full move to SAN or NAS.For fast growing Small or Medium businesses MSA70 can scale to multiple TBytes, by adding additionaldrive bays.

This enclosure is designed to support the 2.5 inch Universal form factor hard drive in either SAS or SATA.Configuration and setup is easy with HP Array Configuration Utility (ACU). The 2U storage supportsdirect attach storage to HP ProLiant and HP Integrity Servers. Enclosures can be cascaded in a 1+1configuration allowing a maximum of 50 drives in a 4U configuration behind each port on the SmartArray P800, E500, P411 or the P812 controller for a total of 100 drives.

The MSA70 is also supported when attached to a HP StorageWorks 2324fc Dual Controller ModularSmart Array (MSA2324fc). The MSA2324fc is a 4Gb Fibre Channel connected 2U storage area network(SAN) or direct connect solution that can accommodate twenty four (24) Small Form Factor (SFF) drivesand is designed for small to medium size departments or remote locations. The MSA2324fc supportsattachment of up to three (3) dual I/O MSA70 SFF JBODs (99 SFF drives)

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Standard Features

DA - 12652   North America — Version 33 — July 30, 2010 Page 4

Key FeaturesKey FeaturesKey FeaturesKey Features AffordabilityAffordabilityAffordabilityAffordability MSA70 provides end-to-end SAS host modular flexible platform in a highcapacity 2U disk drive external direct storage system

FlexibilityFlexibilityFlexibilityFlexibility 2U SFF SAS/SATA allows customer choice. Extends the benefit of tieredstorage to direct attach customers

Investment protectionInvestment protectionInvestment protectionInvestment protection Modular platform allows customers to purchase based on current need andfuture growth, no hidden management charges.

Simplicity: ManageabilitySimplicity: ManageabilitySimplicity: ManageabilitySimplicity: Manageability Manage the array with the highly refined HP Systems Insight Manager

CascadeabilityCascadeabilityCascadeabilityCascadeability Up to 2 enclosures can be connected together to form a single controllerport. Grow storage capacity easily

ReliabilityReliabilityReliabilityReliability Hot plug compatibility: can add or replace hard drives without servicedisruptionRAID levels provide various levels of data protection and availability. RAIDlevel choices provide flexibility. RAID 6 with ADG provides additional levelreliability

High AvailabilityHigh AvailabilityHigh AvailabilityHigh Availability Serviceguard maximizes application availability while protecting dataintegrity. (HP-UX and Open VMS support on selected HP Integrity Serversonly)

HP Portfolio - end-to-endHP Portfolio - end-to-endHP Portfolio - end-to-endHP Portfolio - end-to-endsolutionsolutionsolutionsolution

HP offers a complete portfolio of SAS storage enclosure, Smart ArrayControllers and HP ProLiant and HP Integrity Servers for end-to-end solutionleading the competition

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Standard Features

DA - 12652   North America — Version 33 — July 30, 2010 Page 5

High Levels of StorageHigh Levels of StorageHigh Levels of StorageHigh Levels of StorageDensity, Data Protection,Density, Data Protection,Density, Data Protection,Density, Data Protection,and Functionalityand Functionalityand Functionalityand Functionality

Storage CapacityStorage CapacityStorage CapacityStorage Capacity - The MSA70 enclosure supports up to twenty five 2.5 inch SAS or SATA drivesfor a maximum capacity of 7.5 TB with 300GB SAS drives, 12.5 TB SAS MDL with 500 GB SASMDL drives or 12.5 TB with 500 GB SATA drives.Data ProtectionData ProtectionData ProtectionData Protection - MSA70 is designed for a high level of data protection. It includes redundantfans and power supplies (standard), and support for various RAID levels including RAID 6 withADG (depending upon the Smart Array Controller used).Dual DomainDual DomainDual DomainDual Domain - Dual domain SAS creates redundant pathways from servers to storage devices.The redundant paths created by these configurations reduce or eliminate single points of failurewithin the storage network. This provides increased levels of high availability with redundant pathsfrom the controller to the drives.Storage ManageabilityStorage ManageabilityStorage ManageabilityStorage Manageability - The MSA70 features familiar configuration and management tools suchas Array Configuration Utility (ACU) and HP Systems Insight Manager (SIM). Online ManagementFeatures include: Online Capacity Expansion, Online RAID Level Migration, Online Stripe SizeMigration, Online Spares.Choice of Computing PlatformChoice of Computing PlatformChoice of Computing PlatformChoice of Computing Platform - The MSA70 is designed and qualified for HP ProLiant and HPIntegrity servers.Advanced Data GuardingAdvanced Data GuardingAdvanced Data GuardingAdvanced Data Guarding (RAID 6 with ADG) Fault ToleranceFault ToleranceFault ToleranceFault Tolerance - It allocates two sets of parity dataacross drives and allows simultaneous write operations. This level of fault tolerance can withstandtwo simultaneous drive failures without downtime or data loss.

Low Total Cost ofLow Total Cost ofLow Total Cost ofLow Total Cost ofOwnershipOwnershipOwnershipOwnership

The modular, scalable design of the MSA70 provides an extremely flexible platform. You can buy whatyou need today and purchase additional capacity as your data storage needs grow, instead of making alarge up-front investment. Additional drives and enclosures can be easily added as your needs dictate.

CascadingCascadingCascadingCascading - The MSA70 has the capability of cascading up to two (2) enclosures behind a singleSAS port (depends on the Smart Array Controller).Tiered StorageTiered StorageTiered StorageTiered Storage - MSA70 supports mixing SAS and SATA drives in the same enclosure, allowingyou to more effectively utilize mission critical storage where you need it most.Universal SATA Hard Drive SupportUniversal SATA Hard Drive SupportUniversal SATA Hard Drive SupportUniversal SATA Hard Drive Support- Since the MSA70 supports HP Universal SATA drives, yourinvestment in disk drives is protected and cost is minimized as you add new drives.Pre-Failure WarrantyPre-Failure WarrantyPre-Failure WarrantyPre-Failure Warranty - Drives installed in a MSA70 and monitored under HP Systems InsightManager are supported by a Pre-Failure (replacement) Warranty (3 years for SAS and 1 year forSAS MDL or SATA drives). Pre-Failure Warranty allows for the replacement of designated drives inMSA70 before they actually fail when using HP Systems Insight Manager on HP ProLiant or HPIntegrity servers.NOTE:NOTE:NOTE:NOTE: Some operating systems may not support all of these features.Integrated Configuration and Management ToolsIntegrated Configuration and Management ToolsIntegrated Configuration and Management ToolsIntegrated Configuration and Management Tools - The MSA70 utilizes the standard, integratedset of Smart Array management and utility software for HP ProLiant Servers. These toolsconsistently lower the cost of ownership by reducing training and technical expertise necessary toinstall and maintain HP server storage. HP-UX and Open VMS uses HP Integrity ODE for storageenclosure support.

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Product Highlights

DA - 12652   North America — Version 33 — July 30, 2010 Page 6

MSA70 EnclosureMSA70 EnclosureMSA70 EnclosureMSA70 Enclosure The 2U array houses up to twenty five 2.5 inch Universal hot pluggable SAS or SATA hard drives.Each MSA70 includes the following standard components:

MSA70 base enclosure with redundant power supplies and fan modulesRack mounting hardware kit0.5m mini-SAS cableTwo AC power cords & two PDU interconnect cords

Smart Array P800Smart Array P800Smart Array P800Smart Array P800FeaturesFeaturesFeaturesFeatures

HP's highest performing 16-port PCI-express controller with expander supportExpander support enables the addition of external storage, allowing increased number of drivesfor increased performanceProvides highest level of data protection standard by using RAID 6 with Advanced Data GuardingSupports a maximum of 108 drives (100 drives across four enclosures plus 8 drives in the serverinternal backplane)Supported in a single initiator environmentFor more information see:http://h18004.www1.hp.com/products/quickspecs/12616_na/12616_na.html

Smart Array E500Smart Array E500Smart Array E500Smart Array E500FeaturesFeaturesFeaturesFeatures

HP's first external connect only PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controllerExpander support enables the addition of external storage, allowing increased number of drivesfor increased performanceOffers RAID 0, 1 & 1+0 and can be upgraded with battery-backed write cache (BBWC) modulefor RAID 5Supports a maximum total of 108 hard drivesSupported in a single initiator environmentFor more information see:http://h18004.www1.hp.com/products/quickspecs/12700_na/12700_na.html

Smart Array P411Smart Array P411Smart Array P411Smart Array P411FeaturesFeaturesFeaturesFeatures

The HP Smart Array P411 is HP's PCI Express (PCIe) Serial Attached SCSI (SAS) RAID controllerLow profile, half height card has 8 ports and utilizes DDR2-800 memoryThe P411 is ideal for RAID 0/1, 5, 1+0 & 5+0 and can be upgraded with the 512MB battery-backed write cache (BBWC) module and Smart Array Advanced via license key for RAID 6 &, 6 +0,50 & 60For more information see:http://h18004.www1.hp.com/products/quickspecs/13202_na/13202_na.html

Smart Array P212Smart Array P212Smart Array P212Smart Array P212FeaturesFeaturesFeaturesFeatures

The HP Smart Array P212 is HP's entry level PCI Express (PCIe) Serial Attached SCSI (SAS) RAIDcontrollerThe Low Profile, Half Height card has 8 ports and utilizes DDR2-266 memoryThe P212 is ideal for RAID 0/1, 1+0 and can be upgraded with the 256MB battery-backed writecache (BBWC) module for RAID 5, 5+0For more information see:http://h18004.www1.hp.com/products/quickspecs/13203_na/13203_na.html

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Modular Smart Array 70 Components

DA - 12652   North America — Version 33 — July 30, 2010 Page 7

Smart Array P812Smart Array P812Smart Array P812Smart Array P812FeaturesFeaturesFeaturesFeatures

The HP Smart Array P812 provides superior RAID performance, while delivering high levels ofconnectivity, reliability, and many advanced featuresIncreased connectivity with 8 internal ports and 16 external ports.1 G 72-bit wide DDR2-800 flash-backed write cache (FBWC).Smart Array Advanced Pack (SAAP) license key included standardFor moreinformation see:http://h18004.www1.hp.com/products/quickspecs/13558_na/13558_na.html

HP (AH303A) SC44GeHP (AH303A) SC44GeHP (AH303A) SC44GeHP (AH303A) SC44GeHost Bus AdapterHost Bus AdapterHost Bus AdapterHost Bus Adapter

SAS technology delivers high performance and data bandwidth up to 3Gbp/s per physical link.PCI Express x8 capablePCIe x8 (2.5 GB/s bandwidth)Supported in a Multi Initiator environment

RAIDRAIDRAIDRAID Several fault tolerant configurations keep data available and servers running while drives are beingreplaced - RAID levels that offer fault tolerance include:

RAID 50 (RAID 5+0)RAID 50 (RAID 5+0)RAID 50 (RAID 5+0)RAID 50 (RAID 5+0) protects against failure of one drive (and failure of particular multipledrives). RAID 50 is a nested RAID method that uses RAID 0 striping across RAID 5 arrays. RAID 50tolerates one drive failure in each spanned array without loss of data. RAID 50 requires lessrebuild time than single RAID 5 arrays RAID 50 requires a minimum of six drives.RAID 60 (RAID 6+0)RAID 60 (RAID 6+0)RAID 60 (RAID 6+0)RAID 60 (RAID 6+0) allows administrators to split the RAID 6 storage across multiple externalboxes. RAID 60 requires a minimum of eight drives. RAID 60 is a nested RAID method that usesRAID 0 block-level striping across multiple RAID 6 arrays with dual distributed parity. With theinclusion of dual parity, RAID 60 will tolerate the failure of two disks in each spanned arraywithout loss of data.RAID 6 with ADGRAID 6 with ADGRAID 6 with ADGRAID 6 with ADG: Allocates the equivalence of two parity drives across multiple drives and allowssimultaneous write operations.Distributed Data Guarding (RAID 5): Allocates parity data acrossmultiple drives and allows simultaneous write operations.Drive Mirroring (RAID 1 and 1+0 StripedMirroring): Allocates half of the drive array to data and the other half to mirrored data, providingtwo copies of every file.

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Modular Smart Array 70 Components

DA - 12652   North America — Version 33 — July 30, 2010 Page 8

     The MSA70 utilizes a single, consistent set of utility software for storage and RAID management, setup,configuration and troubleshooting. This consistency reduces the cost of ownership by reducing thetraining and technical expertise necessary to install and maintain your HP server storage solution.

Dual Domain (NEW)Dual Domain (NEW)Dual Domain (NEW)Dual Domain (NEW) Dual domain SAS creates redundant pathways from servers to storage devices. The redundant pathscreated by these configurations reduce or eliminate single points of failure within the storage network.This provides increased levels of high availability with redundant paths from the controller to the drives.Dual domain SAS implementations make it possible to tolerate host bus adapter (HBA) failure, externalcable failure, expander failure, failure in a spanned disk (JBOD) environments.

Configuration UtilitiesConfiguration UtilitiesConfiguration UtilitiesConfiguration Utilities Array Configuration Utility (ACU) [On-line for Microsoft and Linux, Remote Web-Based & Off-line]Option ROM Configuration for Arrays (ORCA), NetWare ACU CPQONLIN (only online support no Webbased support)

Management/HealthManagement/HealthManagement/HealthManagement/HealthUtilitiesUtilitiesUtilitiesUtilities

HP Systems Insight Manager

Array Configuration UtilityArray Configuration UtilityArray Configuration UtilityArray Configuration Utility(ACU)

Provides a graphical view of HP drive array configurations.Easy to use Wizards for configuration.Web Based ACU supports On-Line, Remote Web Based and Off-line configuration.Supports on-line configuration for Microsoft, NetWare and Linux.

HP Systems InsightHP Systems InsightHP Systems InsightHP Systems InsightManagerManagerManagerManager

Powerful storage, server and server option management tool.Monitor storage from a remote central location.Browser based Insight Manager 7 provides full access from anywhere on the Intranet, eliminatingthe need for a dedicated Insight Manager console.

Supported OperatingSupported OperatingSupported OperatingSupported OperatingSystemsSystemsSystemsSystems

HP ProLiant ServersHP ProLiant ServersHP ProLiant ServersHP ProLiant ServersNOTE:NOTE:NOTE:NOTE: For information on supported Operating Systems, please see the following Smart ArrayQuickspecs:E500: http://h18004.www1.hp.com/products/quickspecs/12700_na/12700_na.htmlP600: http://h18004.www1.hp.com/products/quickspecs/12247_na/12247_na.htmlP800: http://h18004.www1.hp.com/products/quickspecs/12616_na/12616_na.htmlP212: http://h18004.www1.hp.com/products/quickspecs/13203_na/13203_na.htmlP411: http://h18004.www1.hp.com/products/quickspecs/13202_na/13202_na.htmlP812: http://h18004.www1.hp.com/products/quickspecs/13558_na/13558_na.html

HP Integrity ServersHP Integrity ServersHP Integrity ServersHP Integrity Servers

HPUX 11iv2/11iv3Open VMSV 8.3 1HNOTE:NOTE:NOTE:NOTE: HPUX 11iv2/11iv3 (for Dual Domain only)Needs I/O Module (#AG779A), and HP SC44Ge Host Bus Adapter or HP Smart Array P800ControllerQualified for the following HP Integrity servers:rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards)NOTE:NOTE:NOTE:NOTE: Open VMS (for Dual Domain only)Needs I/O Module (#AG779A), and HP (AH303A) SC44Ge Host Bus AdapterQualified for the following HP Integrity servers:

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Software Components

DA - 12652   North America — Version 33 — July 30, 2010 Page 9

rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-e cards)MSA2000 G2 ArraysNOTE:NOTE:NOTE:NOTE: For information on supported Operating Systems pleaseseethe MSA2000 G2 Quickspecs:www.hp.com/go/msa2000

NOTE: NOTE: NOTE: NOTE: HPUX 11iv2/11.iv3 (for Dual Domain only)Needs I/O Module (#AG779A), and HP (AH303A) SC44Ge Host Bus Adapter or HP Smart Array P800Controller (single initiator environment only)Qualified for the following HP Integrity servers:rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-ecards)NOTE: NOTE: NOTE: NOTE: Open VMS (for Dual Domain only)Needs I/O Module (#AG779A), and HP (AH303A) SC44Ge Host Bus AdapterQualified for the following HP Integrity servers:rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version that support PCI-ecards)

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Software Components

DA - 12652   North America — Version 33 — July 30, 2010 Page 10

Service and SupportService and SupportService and SupportService and Support Three-year limited parts only warranty, including hardware diagnostic support, pre-failure warranty(coverage of hard drives, memory and processors). The warranty is fully supported by HP Services and aworldwide network of resellers and service providers. In addition 90-day's getting started softwaretelephone support may be covered under the warranty or available for an additional fee. Enhancementsto warranty services are available through HP Care Pack services.

NOTE:NOTE:NOTE:NOTE: The MSA70 has a limited 3 year parts only warranty. SAS drives have 3 year warranty. SAS MDLand SATA drives have a 1 year warranty....

Care Pack services provide a range of life cycle support options that let you choose the service levels thatmeet your business requirements, from basic to mission-critical.

A full range of HP Care Pack hardware and software services are available including:

Installation and start upEducation coursesExtended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7days call window with options including 4-hour response or 6-hour Call To RepairComprehensive range of software technical support for Microsoft, Linux, ProLiant Essentialssolutions helping to deliver high level of application availability. Response times range from 30minutes for critical problems to 2 hours.System Management, Performance Services and Mission Critical Support Solution

Service includes HP branded hardware options qualified for the storage enclosure, purchased at thesame time or afterwards, internal to the enclosure. These will be covered at the same service level andcoverage period as the storage enclosure.

NOTE:NOTE:NOTE:NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices orresellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepackNOTE:NOTE:NOTE:NOTE: For more complete information on HP Services offerings, customers and resellers, please visit usat: http://www.hp.com/hpsNOTE:NOTE:NOTE:NOTE: Additional information regarding worldwide limited warranty and technical support is availableat: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html

HP Care Pack InformationHP Care Pack InformationHP Care Pack InformationHP Care Pack Information Flexible SupportFlexible SupportFlexible SupportFlexible Support 1 Year Support HA101A1-87G

HA103A1-87G

HA104A1-87G

HA105A1-87G

HA109A1-87G

HA110A1-87G

HA111A1-87G

HA112A1-87G

3 Year Support HA101A3-87G

HA103A3-87G

HA104A3-87G

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Service and Support, HP Care Pack, and Warranty Information

DA - 12652   North America — Version 33 — July 30, 2010 Page 11

HA105A3-87G

HA109A3-87G

HA110A3-87G

HA111A3-87G

HA112A3-87G

4 Year Support HA101A4-87G

HA103A4-87G

HA105A4-87G

HA109A4-87G

HA110A4-87G

HA111A4-87G

HA112A4-87G

5 Year Support HA101A5-87G

HA103A5-87G

HA105A5-87G

HA109A5-87G

HA110A5-87G

HA111A5-87G

HA112A5-87G

Installation & Support HA113A1-564

Fixed Care PacksFixed Care PacksFixed Care PacksFixed Care Packs HP 1y NBD 9x5 MSA70 HW Support UF297E

HP 1y 4h 13x5 MSA70 HW Support UF298E

HP 1y 4h 24x7 MSA70 HW Support UF299E

HP 1y 6h ctr MSA70 HW Support UF300E

HP 3y NBD 9x5 MSA70 HW Support UF301E

HP 3y 4h 13x5 MSA60 HW Support UF302E

HP 3y 4h 24X7 MSA70 HW Support UF303E

HP 3y 6h CTR MSA70 HW Support UF304E

HP 1y PW NBD MSA70 HW Support UF305PE

HP 1y PW 4h 13X5 MSA70 HW Support UF306PE

HP 1y PW 4h 24X7 UF307PE

HP 1y PW NBD MSA70 HW Support UF308PE

Hardware Installation, Electronic U8132E

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Service and Support, HP Care Pack, and Warranty Information

DA - 12652   North America — Version 33 — July 30, 2010 Page 12

Step 1: Order Required ItemsStep 1: Order Required ItemsStep 1: Order Required ItemsStep 1: Order Required ItemsModelModelModelModel Shipping DimensionsShipping DimensionsShipping DimensionsShipping Dimensions Part NumberPart NumberPart NumberPart Number

MSA70MSA70MSA70MSA70

I/O ModuleI/O ModuleI/O ModuleI/O Module

HP Storage Works 70 Modular Smart Array 418800-B21

HP StorageWorks Dual Domain I/O Module AG779A

NOTE:NOTE:NOTE:NOTE: The I/O Module is a field upgradeable Option Kit the addition of which in theMSA70 will allow dual domain capability providing higher level of redundancy andreliability.

HP Smart Array P800 Controller (381513-B21) supports Dual Domain on theMSA70 with the addition of the HP StorageWorks Dual Domain I/O Module ina single initiator environment.

Requires Dual port SAS drivesHP (AH303A) SC44Ge Host Bus Adapter supports Dual Domain on the MSA70with the addition of the HP StorageWorks Dual Domain I/O Module in a MultiInitiator environment. Supports only HP-UX and Open VMS and on selected HPIntegrity Servers only.

 

MSA70 Single Port driveMSA70 Single Port driveMSA70 Single Port driveMSA70 Single Port driveBundlesBundlesBundlesBundles

NOTE: NOTE: NOTE: NOTE: Drives in the bundles are Single Port drives only.  

MSA70 Dual Port driveMSA70 Dual Port driveMSA70 Dual Port driveMSA70 Dual Port driveBundleBundleBundleBundle

HP StorageWorks Dual Domain MSA70 7.5TB DP SAS HDD Bundle (MSA70 w/25300GB SFF DP SAS HDD + I/O Module)

AP715A

MSA70 AmericasMSA70 AmericasMSA70 AmericasMSA70 AmericasBundlesBundlesBundlesBundlesNOTE:NOTE:NOTE:NOTE: available in USA &Canada only

HP MSA70 w/ Dual Domain I/O Module; (12) 2.5-in. 146GB SAS Drives w/ cableSolution

AJ923A

(1) HP MSA70 Modular Smart Array Enclosure;(1) HP Modular Dual Domain I/O Module Option Kit;(12) HP 146GB 3G 10K SAS 2.5" SFF DP HDD;(1) Mini SAS 4x2M Cable All

Step 2: Array ControllersStep 2: Array ControllersStep 2: Array ControllersStep 2: Array Controllers     DescriptionDescriptionDescriptionDescription Part NumberPart NumberPart NumberPart Number

Smart Array ControllersSmart Array ControllersSmart Array ControllersSmart Array ControllersSupportedSupportedSupportedSupported(Single Domain)(Single Domain)(Single Domain)(Single Domain)

HP ProLiant ServersHP ProLiant ServersHP ProLiant ServersHP ProLiant Servers  

HP Smart Array P800 controller 381513-B21

HP Smart Array E500 controller 435129-B21

HP Smart Array P600/256 BBWC Controller 337972-B21

HP Smart Array P812 Controller/ 1G Flash Backed Cache Controller 487204-B21

HP Smart Array P411/256MB Controller 462830-B21

HP Smart Array P411/512MB BBWC 462832-B21

HP Smart Array P212/256MB Controller 462834-B21

HP Integrity ServersHP Integrity ServersHP Integrity ServersHP Integrity Servers  

HP Smart Array P800 Controller AD335A

HP Smart Array E500 Controller AD226A

HP Smart Array P600/256 BBWC Controller 337972-B21

NOTE: NOTE: NOTE: NOTE: The HP Smart Array P800 supports the cascading of shelves in a 1+1configuration to allow a maximum of 50 drives in a 4U configuration behind each ofthe two external ports on the HP Smart Array P800 controller for a total of 100 drives

 

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Configuration Information

DA - 12652   North America — Version 33 — July 30, 2010 Page 13

in 4 enclosures.NOTE: NOTE: NOTE: NOTE: Dual Domain is supported for the HP Smart Array P800 Controller (singleinitiator environment only)NOTE: NOTE: NOTE: NOTE: The HP Smart Array P600 supports the cascading of shelves in a 1+1configuration to allow a maximum of 50 drives in a 2U configuration behind or theHP Smart Array P600 controller as the P600 has only a single external port.NOTE: NOTE: NOTE: NOTE: The Smart Array E500 offers RAID 0, 1 and 1+0 and can be upgraded withProLiant server to RAID 5 with battery-backed write cache (BBWC) module - 383280-B21.

SAS ControllersSAS ControllersSAS ControllersSAS ControllersSupportedSupportedSupportedSupported(Dual Domain)(Dual Domain)(Dual Domain)(Dual Domain)

HP ProLiant ServersHP ProLiant ServersHP ProLiant ServersHP ProLiant Servers  

HP Smart Array P800 controller 381513-B21

HP Integrity ServersHP Integrity ServersHP Integrity ServersHP Integrity Servers  

HP SC44Ge Host Bus Adapter AH303A

NOTE: NOTE: NOTE: NOTE: Only HP-UX and Open VMS on selected HP Integrity servers supported.HP Integrity servers that are supported:rx2660, rx3600, rx6600, rx7640, rx8640, Superdome sx2000 (only the version thatsupport PCI-e cards).

 

Step 3: Choose Server(s)/MSA2000 ArraysStep 3: Choose Server(s)/MSA2000 ArraysStep 3: Choose Server(s)/MSA2000 ArraysStep 3: Choose Server(s)/MSA2000 ArraysCompatibilityCompatibilityCompatibilityCompatibility HP ProLiant ServersHP ProLiant ServersHP ProLiant ServersHP ProLiant Servers

For up to date compatibility, please see the following URL for complete Smart Array P600,P800,E500,P411, P212 & P812 Controller compatibility and support information:http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.htmlHP Integrity ServersHP Integrity ServersHP Integrity ServersHP Integrity ServersHP Integrity Server rx2660 with combination PCIx/PCIe riser onlyHP Integrity Server rx3600 with combination PCIx/PCIe backplane onlyHP Integrity Server rx6600 with combination PCIx/PCIe backplane onlyHP integrity Server rx7640 with combination PCIx/PCIe onlyHP integrity Server rx8640 with combination PCIx/PCIe onlyHP integrity Server sx2000 with combination PCIx/PCIe onlyHP StorageWorks 2324fc Dual Controller Modular Smart Array (SFF)

NOTE:NOTE:NOTE:NOTE: HP Integrity Server home:http://www.hp.com/products1/serverconnectivity/support_matrices.htmlNOTE:NOTE:NOTE:NOTE: MSA2300fc home: www.hp.com/go/msa2000fcNOTE:NOTE:NOTE:NOTE: MSA70 is NOT supported behind a MSA2312fc (LFF)

Step 4: Choose Hard DrivesStep 4: Choose Hard DrivesStep 4: Choose Hard DrivesStep 4: Choose Hard DrivesSAS DrivesSAS DrivesSAS DrivesSAS Drives 6G SFF Serial Attached SCSI (SAS) Hard Drives6G SFF Serial Attached SCSI (SAS) Hard Drives6G SFF Serial Attached SCSI (SAS) Hard Drives6G SFF Serial Attached SCSI (SAS) Hard Drives  

HP 72GB 6G SAS 15K 2.5 inch SFF DP ENT HDD 512545-B21

HP 146GB 6G SAS 10K 2.5 inch SFF DP ENT HDD 507125-B21

HP 146GB 6G SAS 15K 2.5 inch SFF DP ENT HDD 512547-B21

HP 300GB 6G SAS 10K 2.5 inch SFF DP ENT HDD 507127-B21

NOTE:NOTE:NOTE:NOTE: 6G drives will work in 3G systems like the MSA70. 6G drives will only functionas 3G drives in a MSA70NOTE:NOTE:NOTE:NOTE: In a single domain environment Dual Port (DP) drives will function as SinglePort (SP) drives only.

 

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Configuration Information

DA - 12652   North America — Version 33 — July 30, 2010 Page 14

NOTE:NOTE:NOTE:NOTE: Only Dual Port (DP) drives will work in the Dual Domain environment. DualDomain environment requires the HP StorageWorks Dual Domain I/O ModuleOption (# AG779A).

SAS Midline (MDL)SAS Midline (MDL)SAS Midline (MDL)SAS Midline (MDL) HP 500 GB 6G SAS 7.2K 2.5 inch SFF DP MDL HDD 507610-B21

NOTE:NOTE:NOTE:NOTE: 6G SAS drives will only function as 3G drives in a MSA70NOTE:NOTE:NOTE:NOTE: In a single domain environment Dual Port (DP) drives will function as SinglePort (SP) drives only.NOTE:NOTE:NOTE:NOTE: Only Dual Port (DP) drives will work in the Dual Domain environment. DualDomain environment requires the HP StorageWorks Dual Domain I/O ModuleOption (# AG779A).

 

SATA DrivesSATA DrivesSATA DrivesSATA Drives HP 250 GB 3G 5.4K 2.5 inch SFF SATA ETY HDD 460355-B21

HP 500 GB 3G SATA 7.2K 2.5 inch SFF MDL HDD 507750-B21

NOTE:NOTE:NOTE:NOTE: SATA drives are not dual port (DP) drives.NOTE:NOTE:NOTE:NOTE: Go to the HP Hard Drive Compatibility table for complete drive compatibilityinformation (http://www.hp.com/products/harddiskdrives). Using hard drives inunsupported configurations will result in voiding the warranty and could result indamage to the drive and/or loss of data

 

NOTE:NOTE:NOTE:NOTE: 500 GB SATA MDL HDDs have not yet been qualified on the MSA2000 G2Arrays.

 

Cable OptionsCable OptionsCable OptionsCable Options Cables used for connecting the HP Smart Array P800/512 BBWC ControllerCables used for connecting the HP Smart Array P800/512 BBWC ControllerCables used for connecting the HP Smart Array P800/512 BBWC ControllerCables used for connecting the HP Smart Array P800/512 BBWC Controller (P/N381513-B21 or AD335A ), the HP Smart Array E500the HP Smart Array E500the HP Smart Array E500the HP Smart Array E500 (P/N 435129-B21 orAH226A), the HP Smart Array P212 (P/N 462834-B21), the HP Smart Array P411(P/Ns 462830-B21 or 462832-B21) or the P812 (P/Ns 487204-B21) to MSA70to MSA70to MSA70to MSA70

 

Mini SAS 4x 2M Cable All 407339-B21

Mini SAS 4x 4M Cable All 432238-B21

Mini SAS 4x 6M Cable All 432239-B21

NOTE: NOTE: NOTE: NOTE: #0D1 will appear after this part number on your sales order if factoryintegration is indicated.

 

Cables used for connecting the HP Smart Array P600/512 BBWC Controller Cables used for connecting the HP Smart Array P600/512 BBWC Controller Cables used for connecting the HP Smart Array P600/512 BBWC Controller Cables used for connecting the HP Smart Array P600/512 BBWC Controller (P/N337972-B21) or the HP SC44Ge Host Bus Adapter (P/N AH303A) to MSA70to MSA70to MSA70to MSA70

 

SAS 4x to Mini SAS 4x 2M 419571-B21

SAS 4x to Mini SAS 4x 4M 419572-B21

SAS 4x to Mini SAS 4x 6M 419573-B21

NOTE: NOTE: NOTE: NOTE: #0D1 will appear after this part number on your sales order if factoryintegration is indicated.

 

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Configuration Information

DA - 12652   North America — Version 33 — July 30, 2010 Page 15

Step 5: Choose Rack OptionStep 5: Choose Rack OptionStep 5: Choose Rack OptionStep 5: Choose Rack OptionHP Universal RackHP Universal RackHP Universal RackHP Universal Rack HP Universal Rack 10642 G2 Shock Rack AF002A

HP Universal Rack 10642 G2 w/Ext Shock Rack AF004A

HP Universal Rack 10636 G2 Pallet ALL AF011A

HP Universal Rack 10636 G2 Shock Rack AF012A

HP Universal Rack 10636 G2 Crated ALL AF013A

HP Universal Rack 10636 G2 w/Ext Shock Rack AF014A

HP 10642 G2 200mm Extn Shock Rack AF034A

HP 10647 G2 200mm Extn Shock Rack AF044A

HP RackHP RackHP RackHP Rack HP Rack S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Configuration Information

DA - 12652   North America — Version 33 — July 30, 2010 Page 16

  HP StorageWorks 50 ModularHP StorageWorks 50 ModularHP StorageWorks 50 ModularHP StorageWorks 50 ModularSmart Array EnclosureSmart Array EnclosureSmart Array EnclosureSmart Array Enclosure

HP StorageWorks 60 ModularHP StorageWorks 60 ModularHP StorageWorks 60 ModularHP StorageWorks 60 ModularSmart ArraySmart ArraySmart ArraySmart Array

HP StorageWorks 70 ModularHP StorageWorks 70 ModularHP StorageWorks 70 ModularHP StorageWorks 70 ModularSmart ArraySmart ArraySmart ArraySmart Array

Total Drive CountTotal Drive CountTotal Drive CountTotal Drive Count 10 SAS10 SATA

10 SAS MDL

12 SAS12 SATA

12 SAS MDL

25 SAS25 SATA

25 SAS MDL

Maximum StorageMaximum StorageMaximum StorageMaximum Storage 3TB SAS per enclosure or 5TBSAS MDL or SATA

24 TB per enclosure (using 2TBSATA disk drives)

7.5 TB SAS, or 12.5 TB SASMDL per enclosure or 12.5 TB

SATA

Expansion OptionsExpansion OptionsExpansion OptionsExpansion Options None None None

Host InterfaceHost InterfaceHost InterfaceHost Interface SAS SAS SAS

Drive InterfaceDrive InterfaceDrive InterfaceDrive Interface SAS/SATA/SAS MDL SAS/SATA/SAS MDL SAS/SATA/SAS MDL

Drive Form FactorDrive Form FactorDrive Form FactorDrive Form Factor 2.5 in. 3.5 in. 2.5 in.

Clustering SupportClustering SupportClustering SupportClustering Support No HP-UX only HP-UX only

SAN Backup SupportSAN Backup SupportSAN Backup SupportSAN Backup Support No No No

Storage Mirroring SupportStorage Mirroring SupportStorage Mirroring SupportStorage Mirroring Support Yes Yes Yes

Systems Insight ManagerSystems Insight ManagerSystems Insight ManagerSystems Insight ManagerSupportSupportSupportSupport

Yes Yes Yes

OS SupportOS SupportOS SupportOS Support Windows, Linux, NetWare Windows, Linux, NetWare,SCO,HP-UX, Open VMS

Windows, Linux, NetWare,SCO, HP-UX, Open VMS,

VMware

Rack HeightRack HeightRack HeightRack Height 1U 2U 2U

Warranty Warranty Warranty Warranty (parts/labor/onsite) 3-0-0 3-0-0 3-0-0

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Family Comparison

DA - 12652   North America — Version 33 — July 30, 2010 Page 17

LED Indicators for HDDsLED Indicators for HDDsLED Indicators for HDDsLED Indicators for HDDs Online (bottom)

Drive failure LED (top)

LED Indicators on FrontLED Indicators on FrontLED Indicators on FrontLED Indicators on FrontPanelPanelPanelPanel

Heartbeat LED

Fault LED

UID LED

LED Indicators on RearLED Indicators on RearLED Indicators on RearLED Indicators on RearPanelPanelPanelPanel

I/O Module LED

UID button/LED

Heartbeat LED

Fault LED

Power On/Standby button system

Power supply LEDFan Module LED

Host InterfaceHost InterfaceHost InterfaceHost Interface 4 x wide SAS 3Gb/s ports

Maximum Number ofMaximum Number ofMaximum Number ofMaximum Number ofDrivesDrivesDrivesDrives

Up to 25 (twenty five) 2.5 inch SAS or SATA drives

Temperature RangeTemperature RangeTemperature RangeTemperature Range OperatingOperatingOperatingOperating 50° to 95° F (10° to 35° C)

ShippingShippingShippingShipping -40° to 150° F (-40° to 66° C)NOTE: NOTE: NOTE: NOTE: Rated 1°C per 1000 feet of elevation to 10,000 ft.

Relative HumidityRelative HumidityRelative HumidityRelative Humidity OperatingOperatingOperatingOperating 10% to 90%

Non-operatingNon-operatingNon-operatingNon-operating Up to 95%

Input PowerInput PowerInput PowerInput PowerRequirementsRequirementsRequirementsRequirements

Rated Input VoltageRated Input VoltageRated Input VoltageRated Input Voltage 100 to 240 VAC

Rated Input FrequencyRated Input FrequencyRated Input FrequencyRated Input Frequency 50 to 60 Hz

Rated Input CurrentRated Input CurrentRated Input CurrentRated Input Current 3.9A at 110 VAC typical, 6A Maximum

Input PowerInput PowerInput PowerInput Power (max) 345 W

Heat DissipationHeat DissipationHeat DissipationHeat Dissipation(maximum)

1175 Btu/hrNOTE: NOTE: NOTE: NOTE: Input Power and Heat Dissipation specifications are maximum values and apply to worst-caseconditions at full rated power supply load. The power/heat dissipation for your installation will varydepending on the equipment configuration.

RAID SupportRAID SupportRAID SupportRAID Support See QuickSpecs for Smart Array Controllers P600, P800, E500, P212, P411 & P812http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/index.htmlMSA2000 G2: See Quickspecs for MSA2000 G2: www.hp.com/go/msa2000

Upgradeable FirmwareUpgradeable FirmwareUpgradeable FirmwareUpgradeable Firmware Yes, Offline only. Firmware updates available through hp.com

Disk Drives andDisk Drives andDisk Drives andDisk Drives andEnclosure ProtocolEnclosure ProtocolEnclosure ProtocolEnclosure ProtocolSupportSupportSupportSupport

HP 2.5 inch 3G SAS

I/O ModuleI/O ModuleI/O ModuleI/O Module Connector TypeConnector TypeConnector TypeConnector Type IPass (mini-SAS) 4x (SFF8088)

Number of PortsNumber of PortsNumber of PortsNumber of Ports Two (one IN, other is OUT)

Modular Smart Array 70Modular Smart Array 70Modular Smart Array 70Modular Smart Array 70CabinetCabinetCabinetCabinet

2U Rack Form Factor

DimensionsDimensionsDimensionsDimensions (HxWxD) 3.47 x 17.64 x 23.25 in (8.8 x 44.8 x 59 cm)

WeightWeightWeightWeight (Net) 35 lb (15.9 kg)

Weight Weight Weight Weight (Gross) 48 lb (24.6 kg)

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Technical Specifications

DA - 12652   North America — Version 33 — July 30, 2010 Page 18

© Copyright 2010 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice.

The only warranties for HP products and services are set forth in the express warranty statements accompanying such products andservices. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorialerrors or omissions contained herein.

For hard drives, 1 GB = 1 billion bytes. Actual formatted capacity is less.

QuickSpecs HP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart ArrayHP StorageWorks 70 Modular Smart Array

Technical Specifications

DA - 12652   North America — Version 33 — July 30, 2010 Page 19