How might Flow Vortex Analysis Help in Characterization of ICA Aneurismal Flow: A Case Study Using...
-
Upload
baldwin-boyd -
Category
Documents
-
view
217 -
download
0
Transcript of How might Flow Vortex Analysis Help in Characterization of ICA Aneurismal Flow: A Case Study Using...
How might Flow Vortex Analysis Help in Characterization of ICA Aneurismal Flow: A Case Study Using Siemens CFD Prototype
Software and VTK
Jingfneg Jiang1, Kevin Sunderland1, Gouthami Chintalapani2, Kevin Royalty2 and Charles M Strother3
1Michigan Technological University2Siemens Medical Solutions (USA), Inc.
3University of Wisconsin-Madison
ASNR 2015
1. J. Jiang and K. Sunderland are supported by a research contract from Siemens Medical Solution (USA), Inc.
2. G. Chintalapani and K. Royalty are employed by Siemens Medical Solution (USA), Inc.
Disclosure
Hemodynamics plays a vital role in the origin, growth and rupture of aneurysms
A growing body of literature indicates computational fluid dynamics (CFD) simulations could potentially provide insight into clinical management of cerebral aneurysms1,2
Introduction
CFD produces results of mathematical models (i.e. Navier-Stokes equations) that researchers postulate capture the basic laws governing the physics of fluid flows. Widely used and valued for industrial
applications such as airplane design
Image-based CFD simulations3 are under a rapid development “Patient-specific” vessel geometry is
currently used Patient-specific physiological data could
potentially further enhance the predictions
What is CFD?
Clinical Utility of CFD? Clinical Utility of CFD? Significant anatomical and
hemodynamic variations make interpretation of aneurismal dynamics difficulty
Viewing time-resolved 3D hemodynamic (hundreds of) images may become a time-consuming and difficult task for physicians
Jiang and Strother, ICS, 2009
Objective:Objective: To improve potential clinical utility of CFD, automated flow analysis may be useful
Vortex core may provide relevant information related to flow physics The usefulness of vortex core analysis was demonstrated through a pilot study using 5
sets of ICA tandem (closely-space) aneurysms
Study DesignStudy Design:• 10 lateral ICA aneurysms in 5 patients; two closely spaced aneurysms in each patients • CFD simulations of those six aneurysms were performed using Siemens CFD prototype software • Automated vortex core analysis was performed using in-house software derived from Visualization ToolKit (VTK, Kitware Inc., NY)
Purpose
Workflow
Step 1: CFD Simulations
CFD Simulation Conditions Typical waveforms (transient flow rates) were selected based
on averaged Phase-contrast MR measurements6,7 For instance, averaged flow rate at the ICA was 280 ml/min
Transient CFD simulations were performed for 2 cardiac cycles A voxel-based method8 (i.e. Siemens CFD prototype solver)
was used to solve the Navier-Stokes equations Time steps were sufficiently fine and were adaptively chosen
by the Siemens CFD solver 18 phases/steps of the second cardiac cycles were analyzed
Step2: Isolate Aneurismal Flow
This algorithm was based on an published aneurysm extraction algorithm10 and implemented in the VTK
Vortex Analysis The well-known Lambda2 method by Jeong
and Hussain99 was used to define the vortex core areas Two negative eigenvalues from a matrix derived from
local velocity gradients
A simple Marching-cube algorithm was used to segment out the vortex core volumes Implemented in the VMTK5
Temporal Flow Stability Flow stability was assessed by tracking changes of
the vortex core(s) over time Calculate a temporally –averaged velocity field Calculate the time-averaged vortex core(s) from the time-
average velocity field (purple colored vortex core below) Compare the (volume) overlap between the time-averaged
vortex core(s) and the instantaneous vortex core(s) The (temporal) flow stability assessment is between 0 and 1
and there, is easy to interpret Low overlap means low (temporal) flow stability
The extracted vortex cores were visually consistent with velocity Vector plot
Vortex Cores Velocity Plot
Results
Purple and green colors represent two vortex cores of the proximal and distal aneurysms, respectively
The calculate overlap value was consistent with visual assessments of temporal flow stability
Results
Overlap = 0.57 Overlap = 0.87
Mean Overlap of Vortex Cores
Proximal Aneurysms 0.90 ± 0.06
Distal Aneurysms 0.78 ± 0.08
Summary Results
• Temporal flow stability in proximal aneurysms were greater as compared to that in distal aneurysms (p = 0.03 [rank-sum test]) in data investigated
• Flow instability in the distal aneurysm might be induced by disturbed flow coming out from the proximal aneurysm
Vortex analysis results are yet to be verified with imaging measurements (e.g. Phase-contrast MR angiography)
Only 10 aneurysms were studied
Study Limitations
Conclusion and Future WorkPreliminary results demonstrate that vortex-
core analysis can potentially provide relevant information to characterize aneurismal hemodynamics Assessment of temporal flow stability through
vortex core analysis might be an independent variable
Future work is to verify results and explore its use in a clinical setting
[1]J. R. Cebral, F. Mut, M. Raschi, E. Scrivano, R. Ceratto, P. Lylyk, and C. M. Putman, "Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment," AJNR Am J Neuroradiol, vol. 32, pp. 27-33, Jan 2010.
[2]J. Xiang, V. M. Tutino, K. V. Snyder, and H. Meng, "CFD: computational fluid dynamics or confounding factor dissemination? The role of hemodynamics in intracranial aneurysm rupture risk assessment," AJNR Am J Neuroradiol, vol. 35, pp. 1849-57, Oct 2014.
[3]D. A. Steinman, J. S. Milner, C. J. Norley, S. P. Lownie, and D. W. Holdsworth, "Image-based computational simulation of flow dynamics in a giant intracranial aneurysm," AJNR Am J Neuroradiol, vol. 24, pp. 559-66, Apr 2003.
[4]N. M. Kakalis, A. P. Mitsos, J. V. Byrne, and Y. Ventikos, "The haemodynamics of endovascular aneurysm treatment: a computational modelling approach for estimating the influence of multiple coil deployment," IEEE Trans Med Imaging, vol. 27, pp. 814-24, Jun 2008.
[5]L. Antiga and D. A. Steinman, "Robust and objective decomposition and mapping of bifurcating vessels," IEEE Trans Med Imaging, vol. 23, pp. 704-13, Jun 2004.
[6]M. D. Ford, N. Alperin, S. H. Lee, D. W. Holdsworth, and D. A. Steinman, "Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries," Physiol Meas, vol. 26, pp. 477-88, Aug 2005.
References
[7]M. Zhao, S. Amin-Hanjani, S. Ruland, A. P. Curcio, L. Ostergren, and F. T. Charbel, "Regional cerebral blood flow using quantitative MR angiography," AJNR Am J Neuroradiol, vol. 28, pp. 1470-3, Sep 2007.
[8] V. Mihalef, P. Sharma, A. Kamen, and T. Redel, “An immersed porous boundary method for computational fluid dynamics of blood flow in aneurysms with flow diverters,” in Proceedings of the ASME Summer Bioengineering Conference, 2012.
[9] J. Jeong and E. Hussain, “On the identification of a vortex”, J. of Fluid Mechanics, vol. 285, pp. 69-95, 1995.
[10] J. Jiang and C. M. Strother, "Interactive decomposition and mapping of saccular cerebral aneurysms using harmonic functions: its first application with "patient-specific" computational fluid dynamics (CFD) simulations," IEEE Trans Med Imaging, vol. 32, pp. 153-64, Feb 2013.
References