House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection...

31
House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile: 0274 522 159 Work: 09 5334521 www.fchi.co.nz NZS 4306-2005 Full Indemnity Insurance Date of inspection 10/04/2014 House inspection Mr and Mrs Smith Address: 123 Sample St Auckland Pre purchase - Condition report Agent Present: N/A Buyer Present: Yes Weather at time of Inspection Dry Approximate age of house: 1995 Bedrooms: 4 Plus Study Cladding: Brick veneer & Fibrolite textured – No cavity on fibrolite Roof: Corrugated Profile

Transcript of House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection...

Page 1: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

House Inspection Specialists

Sum Insured Home Rebuild Cost Appraisals

Pre Purchase Inspections

Mobile: 0274 522 159

Work: 09 5334521

www.fchi.co.nz

NZS 4306-2005 Full Indemnity Insurance

Date of inspection 10/04/2014

House inspection Mr and Mrs Smith

Address: 123 Sample St

Auckland

Pre purchase - Condition report

Agent Present: N/A

Buyer Present: Yes

Weather at time of Inspection Dry

Approximate age of house: 1995

Bedrooms: 4 Plus Study

Cladding: Brick veneer & Fibrolite textured – No cavity on fibrolite

Roof: Corrugated Profile

Page 2: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Publication and Use Neither the whole nor any part of this Report or any other report (whether verbal or written) or any reference to this Report or any such other report may be: included in any published document, circular or statement, whether hardcopy or electronic; transferred to any person other than the Customer; or distributed or sold, in each case without first obtaining the written approval of the Company. The Report is not to be used in any litigation except with the prior written approval of the Company

Page 3: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

CONTENTS

KITCHEN ...................................................................................................................................................... 4

LIVING ROOMS............................................................................................................................................ 5

BEDROOMS ................................................................................................................................................. 7

BATHROOMS –WET AREAS .......................................................................................................................10

GARAGE ....................................................................................................................................................13

EXTERIOR ......................................................................................................................................................14

EXTERIOR CLADDING & JOINERY ..............................................................................................................14

SITE ...........................................................................................................................................................17

SUB-FLOOR CONSTRUCTION ....................................................................................................................18

ROOF .........................................................................................................................................................19

ROOF SPACE ..............................................................................................................................................19

ELECTRICAL ...............................................................................................................................................21

PLUMBING ................................................................................................................................................22

SUMMARY .....................................................................................................................................................24

DISCLAIMER / LIMITATIONS OF THIS REPORT ..............................................................................................25

FUTURE ISSUES A MUST READ ......................................................................................................................28

CERTIFICATE OF INSPECTION IN ACCORDANCE WITH NZS 4306 2005 .........................................................31

Page 4: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 4

COMMENTS: Photo

KIT

CH

EN

Oven 2 Working at time of inspection- Handle loose

Walls 3 No water ingress issues found

Ceiling 3 No water ingress issues found

Floor Covering 3 No issues found

Windows 3 Aluminium - No water ingress issues found

Cabinetry 2 Water damage on kitchen doors K1

Bench tops 3 No issues found

Cook Top 3 Working at time of inspection

Waste disposal 3 Working at time of inspection - No leaks

Range hood 3 Working at time of inspection

Ventilation N/A

Photo K1

Water damaged kitchen doors on front of sink unit

Any additional comments: Action Required

MAINTENANCE

Page 5: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 5

COMMENTS: Photo

LIV

ING

RO

OM

S

Doors 3 All hardware working - Doors line up with frame

Walls 2 Elevated moisture readings found L1

Ceiling 3 No water ingress issues found

Floor Coverings 3 No issues found

Windows 3 Water ingress issues left side of window L4

Fireplace 3 Fireplace needs to be checked by approved person L3

Ventilation Fitted and working at time of inspection

Air-Conditioning N/A

Lighting 3 No issues found

Photo L1

Elevated readings below the window above skirting’s

This appears to have come in via the pergola direct fixing to the cladding system

This is known as a high risk area where the bolts are bolted into the framing

Photo L2

Please get the fireplace checked by a certified installer before use

Page 6: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 6

Photo L3

Other than the window in the picture no other water ingress issues were found in this area

Photo L4

Water damaged window jamb

This is very common for this type of window

This will need the extrusion beads popped and re siliconed on the exterior along with the butt glass re sealed

Any additional comments: Action Required

MAINTENANCE

Page 7: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 7

COMMENTS: Photo

BED

RO

OM

S

Doors 3 N/A

Walls 2 Elevated moisture readings found BR2 BR4 BR7

Ceiling 3 No water ingress issues found

Floor Coverings 3 No issues found

Windows 2 Water ingress issues left side of window BR6

Wardrobe 3 All hardware working - Doors line up with frame

Fan N/A

Air-conditioning Working at time of inspection

Air movement system

Working at time of inspection

Lighting 3 No issues found

Photo BR1

Water ingress issues below this window as described below

Photo BR2

Water damaged area on internal wall in bedroom one

This has come in via the exterior cladding detail finishing where the gutter and flashings meet the wall cladding as shown in photo R2

Further investigation is required to establish if there is any long term rot to the timber structure

Page 8: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 8

Photo BR3

Water ingress issues below window as described in photo BR2

Photo BR4

Water damaged area

Elevated readings on left side of wall under window

The entry point of water penetration appears to be from the flashing and gutter junctions as described in the photo BR2

Further investigation is required to establish if there is any long term rot to the timber structure

Photo BR5

No water ingress issues found

Page 9: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 9

Photo BR6

Window as described below

Photo BR7

Water penetration issues below the window

Elevated moisture readings are very high on the wall and skirting and the damage is visible on the swollen skirtings

This is common for water leaks due to the style of window

Further investigation is required to establish if there is any long term rot to the timber structure

Photo BR8

No water ingress issues found

Any additional comments: Action Required

YES

Page 10: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 10

COMMENTS: Photo

BA

THR

OO

MS –W

ET A

REA

S

Doors 3 All hardware working - Doors line up with frame

Walls 2 Elevated moisture readings found B4

Ceiling 3 No water ingress issues found

Floor Coverings 3 No issues found

Shower 1 Both showers need maintenance B2 B4

Windows 3 Aluminium - No water ingress issues found

Vanity 2 Old water damaged found B5

Ventilation N/A

Toilet 3 Cistern working - No leaks found

Bath 3 Tapware working - No issues found

Heated towel rail N/A

Laundry tub 3 Tapware working - Waste pipes checked - No leaks

Laundry ducting N/A

Tap pressure 3 N/A

Photo B1

No water ingress issues found below windows

Page 11: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 11

Photo B2

Shower is leaking behind the walls on each corner

Given the age of the shower this will have to be removed and a new one installed

This is common for 70% of these showers installed due to the style of drainage systems relying on silicone to divert water away from behind the wall linings

Photo B3

Main Bathroom

Photo B4

This shower has been replaced recently given the new style of drainage system

Unfortunately this has not been set up properly and it is allowing water to flow out the right side end panel when tested

Water damage to wall and skirting and particle board flooring were visible and high readings on the trotec 650 meter

Page 12: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 12

Photo B5

Wash basin has had water overflow at some stage and damage to the side panel was visible

Photo B6

No water ingress issues found

Any additional comments: Action Required

MAINTENANCE

Page 13: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 13

COMMENTS: Photo

GA

RA

GE

Doors 3 Doors line up with frame - Hardware working

Walls 3 No water ingress issues found

Ceiling 3 No water ingress issues found

Floor Coverings 3 No issues found

Windows N/A

Garage Door 3 Garage doors runs freely - Motor working at time of inspection

Photo G1

No water ingress issues found

Any additional comments: Action Required

NONE

Page 14: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 14

Exterior

COMMENTS: Photo

EXTE

RIO

R C

LAD

DIN

G &

JO

INER

Y

Cladding Style Brick veneer – Monolithic cladding – No cavity

Cracks must be repaired by grinding back joints and re taping and texturing

X2

Roof to wall junctions

No issues found

Surface Coating Recently painted 3 years ago – Repairs needed X2

Cladding to Roof Junction

No issues found

Cladding to Wall Junctions

No issues found

Vertical Relief Joints

N/A

Horizontal Relief Joints

N/A

Windows type Aluminum window needs attention - Leaking BR6

Window Head flashing

Head flashings need to be fitted above garage door X1

Window sill flashing

N/A

Drainage holes windows

No issues found

Cavity System Fibrolite No cavity system needed at time of construction

Photo X1

No head flashings fitted above the garage door

This will allow wicking under the door head and under the cladding and will cause long term damage to the framing

It is possible damage to the framing may have already occurred

Further investigation is required to establish if there is any long term rot to the timber structure

Page 15: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 15

Photo X2

The crack under the window will need to be repaired by a certified repairer

Cracks like this will allow water ingress into the dwelling wall space given the cladding is only 7.5mm thick and has no drainage systems in place to deal with excess water and no air flow behind the cladding system

Further investigation is required to establish if there is any long term rot to the timber structure

Photo X3

Window extrusion will need to be siliconed where it has cracked as these windows only rely on silicone for a weather tight seal

Photo X4

High risk area of water ingress as there is no flashings to stop water getting in behind the cladding system

Further investigation is required to establish if there is any long term rot to the timber structure

Page 16: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 16

Photo X5

No capillary breaks where the cladding system meets the concrete ledge at the base of the dwelling

If water is trapped behind the cladding it cannot get out and can rot out the timber framing long term

It is possible this may have already happened

Further investigation is required to establish if there is any long term rot to the timber structure

Photo X6

Pergola is directly fixed to the cladding system and this could have a high risk of water ingress damage to the framing

Any penetrations into the cladding system even if there was a cavity system is a high risk for water entry points

Photo X7

No soffits

The barge board trim has been nailed directly into the cladding system

This is a very high risk area of water ingress issues from this method of construction

Having no soffits will increase the risk of water ingress issues due to no weather protection above the windows and flashings

Any additional comments: Action Required

YES

Page 17: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 17

COMMENTS: Photo

SITE

Slope No excess water found near dwelling

Fencing Normal movement for age

Paths/driveway Normal cracks from movement

Surface water None at time of inspection

Gates No issues found

Retaining wall No movement found

Pergola Pergola is direct fixed to the wall cladding - High risk area

Photo ST1

Direct fixing to the wall cladding system as described in exterior wall claddings

Any additional comments: Action Required

YES

Page 18: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 18

COMMENTS: Photo

SUB

-FLO

OR

CO

NST

RU

CTI

ON

Materials Timber and concrete base

Piles Posts into ground - Minimal movement

Joists-Bearers Timber - No rot found

Flooring Particle board flooring - No water damage seen at time of inspection

Ventilation Air movement vents fitted

Ground condition Ground condition dry

Ground clearance 150mm from the top of the floor to the paved surface- This did not happen in the courtyard area and will need an invasive test carried out

Foil paper N/A

Photo SF1

Ground dry

Insulation fitted to sub floor

Any additional comments: Action Required

YES

Page 19: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 19

COMMENTS: Photo

RO

OF

Materials Galvanised corrugated roof

Slope Roof materials correct for pitch of roof

Flashings Flashings rusty - Maintenance needed R3

Fixings No issues found

Penetrations N/A

Coating and Surface

Good condition

Soffits Minimal soffits for weather protection

Barge Boards, Facia

Wooden barge boards - No rot found

Gutters Plastic gutter - No leaks at time of inspection

Down pipes Plastic - No leaks found

Valley No issues found

Hip and Ridges No issues found

Chimney N/A

RO

OF

SPA

CE

Construction Timber framing - No rot seen at time of inspection

Dampness None seen at time of inspection

Insulation Insulation was present on inspection- This is not a statement as to the efficency or rating of the insulation

Insect & Pests None seen at time of inspection

Rotting Timbers None seen at time of inspection

Page 20: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 20

Photo R1

Roofing iron is in good condition

Photo R2

This junction has had issues with water leaks from when the dwelling was built

This area is responsible for two rooms leaking

This area must be modified by a LBP builder and flashings must be upgraded

Further investigation is required to establish if there is any long term rot to the timber structure

Photo R3

Rusty flashing along two walls above the pergola needs replacing

Any additional comments: Action Required

MAINTENANCE

Page 21: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 21

COMMENTS: Photo

ELEC

TRIC

AL

Wiring TPS Wiring is a current wiring system - No issues found what could be seen

Fitting All lights checked - No wall sockets checked

Distribution panel Trip switches fitted - Cover fitted

Ceiling Fans N/A

Air conditioning Working at time of inspection

Outdoor Lights/power points

Working at time of inspection

Main Panel No issues found

Gas Supply N/A

Alarm All working at time of inspection

Smoke Detector Smoke detectors need to be fitted

Heating Systems Working at time of inspection

Venting Systems Working at time of inspection

Central Vac N/A

Spa N/A

Pool N/A

Photo EL1

No issues found

Page 22: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 22

COMMENTS: Photo

PLU

MB

ING

Feed Pipes Mixture of pipe feeds fitted - No issues found

Taps & Fittings All taps working - No leaks

Waste Pipes No leaks found

Gulley Traps Lids fitted - Waste flowing

Hot Water Cylinder

Electric - No leaks - Strap fitted

Toilets All cisterns working - No leaks found

Water toby No lid fitted

Plumbing exterior penetrations

All penatrations are sealed at time of inspection

Water tanks N/A

Septic tank N/A

Photo P1

No leaks found

Page 23: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 23

Photo P2

Some of the plumbing appears to be very cheap plastic fittings and are known to become very brittle over time

Page 24: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 24

SUMMARY

1994 dwelling

Two levels

Brick veneer and block and fibrolite with no cavity system needed on the fibrolite textured board at time of construction

Aluminium windows

Galvanised colour steel roof

My concerns with this dwelling is that there are no soffits for weather protection on the windows or cladding system and given there are already a few leaks in the dwelling, what is the condition of the framing behind the cladding in these areas

We have not had much rain over the last few months and given the moisture content and damaged skirting’s on these areas of concern, there may already be long term damage to the framing

These types of cladding systems do not have any spacing’s between the cladding and framing and this will allow rot into the framing if water enters the wall space

This dwelling is built up on the hill which will be more susceptible to wind and heavy rain on the cladding system and this makes this style of dwelling more vulnerable to leaks given the design and flashing systems and capillary breaks that have not been installed

If you wish to proceed with this dwelling it will require an invasive test which will have a series of holes drilled through the exterior and samples of the timber sent to a lab for tests to see if there is any rot present

The dwelling will also need a considerable amount of upgrading with flashings etc to try and minimise the risks of water ingress issues in the future or the other alternative is to re-clad the fibrolite areas on a cavity system and a new cladding material fitted

All areas of concern are highlighted in my report and most will need a LBP builder to do the repairs

Any questions please call

Mark Muller

25 Years building experience

15 Years water ingress issues

Small Claims Building Investigator for the Courts

Page 25: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 25

FIRST CHOICE HOUSE INSPECTIONS

DISCLAIMER / LIMITATIONS OF THIS REPORT

Terms and Conditions Applicable to Residential Building Inspection Reports Purpose The building inspection report (“Report”) is prepared by First Choice House Inspections Limited (“FCHL”) for the specific purposes of assessing the general condition of the building and identifying defects that are readily apparent at the time of inspection based on the limited visual, non-invasive inspection as further described below in the Scope and Limitations & Exclusions sections. No responsibility is accepted in the event that the Report is used for any other purpose. Scope The Report is based on a limited visual, above ground, non-invasive inspection of the standard systems and components of the building. FCHL does not open up, uncover or dismantle any part of the building as part of the inspection or undertake any internal inspection of the building. The procedure for the inspection will be conducted in accordance with NZS 4306:2005. New Zealand Standard; Residential Property Inspection.

Report Limitations & Exclusions

The Report is a guide only (as per New Zealand Standards) and not a guarantee or warranty as to the state of the building or any product, system or feature in the building.

Areas of the building that the inspector believes to be potential problem areas for moisture ingress are checked with a non-invasive moisture meter. Rotting of timber framing and/or the presence of toxic moulds however, can only be determined by invasive testing which requires the removal of wall linings. This cannot be done without the written consent of the owner and is outside the scope of the Report. The Report is not a specialist weathertightness report. FCHL accepts no responsibility or liability for any omission in its inspection or the Report related to defects or irregularities which are not reasonably visible at the time of the inspection or which relate to components of the building:

- which are below ground or which are concealed or closed in behind finished surfaces (such as plumbing, drainage, heating, framing, ventilation, insulation or wiring);

- which required the moving of anything which impeded access or limited visibility (such as floor coverings, furniture, appliances, personal property, vehicles, vegetation, debris or soil) – FCHL does not move owner/occupier items for the purposes of the inspection;

- to which access is not reasonably and safely available to carry out a visual inspection. This may include roofs, subfloor areas and ceiling cavities and high, constricted or dangerous areas for which inspection is not permitted by Occupational Safety and Health regulations.

In addition, the customer accepts that FCHL will not detect some defects because: the defect may only occur intermittently; the defect has been deliberately concealed; or FCHL has been given incorrect information by the customer or any third party. If you believe that any of these circumstances apply then you should immediately contact FCHL in order to try and resolve. Any area, system or component of the building or any item, feature or system not specifically identified in the Report as having been inspected was not included in the scope of the inspection. This includes the condition and location of any special features or services, underground services drainage or of any systems including electrical, plumbing, gas or heating except as otherwise may be described in the Report.

Page 26: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 26

On request, specialist inspections can be arranged of weathertightness or structure or of any systems including electrical, plumbing, gas or heating. Descriptions in the Report of systems or appliances relate to the existence of such systems or appliances only and not the adequacy, efficiency or life expectancy of such systems or appliances. The Report:

- is not a structural survey, engineer’s report, weathertightness inspection or a report on the building’s seismic safety. FCHL can assist with arranging such arranging such specialist third party inspections upon request;

- does not assess compliance with the requirements of any legislation (including, any act, regulation, code or by-law) unless otherwise stated;

- is not a geotechnical, site or environmental report. FCHL makes no representation as to the existence or absence of any or “hazard” (as defined in the Health and Safety in Employment Act) or any “hazardous substance”, “natural hazard” or “contaminant” (as those terms are defined in the Resource Management Act) in the building or property;

Title and Local Authority Records FCHL has not undertaken any title search and assumes all improvements are within the legal boundaries of the property. No survey of the property or any search of information held by the territorial authority or any other relevant authority has been undertaken. It is recommended that the customer conducts its own Land Information Memorandum or Council property file search. Unit Title Properties If the property is a Unit Title property, the inspection and Report is limited to the actual unit and any accessory unit(s) and does not extend to the remainder of the building or the common areas. FCHL recommends the customer obtain a copy of the financial statements and minutes from meetings of the Body Corporate to establish the history of the inspected property under such Body Corporate. Responsibility to Third Parties Our responsibility in connection with this Report is limited to the customer to whom the Report is addressed and to that customer only. We disclaim all responsibility and will accept no liability to any other party without first obtaining the written consent of FCHL and the author of the Report. FCHL reserves the right to alter, amend, explain or limit any information given to any other party. Publication Neither the whole nor any part of the Report (or any other report provided by FCHL, whether written or verbal) may be published or included in any published document, circular or statement whether in hard copy or electronic form or otherwise disseminated or sold without the prior written approval of FCHL and the inspector. Claims & Disputes

Should any dispute arise as a result of the inspection or the Report, it must be submitted to FCHL in writing as soon as practically possible but in any case, within ten working days of discovery. The customer agrees that in the event of a dispute, the contents of the Report may not be used to satisfy any terms of a sale and purchase agreement until the disagreement/dispute has been resolved. In the event the customer nevertheless enters into an unconditional agreement for purchase of the subject property or makes an existing agreement

Page 27: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 27

unconditional prior to resolution of the dispute, the customer shall be deemed to have waived the customer’s rights to continue with and/or make any future claim against FCHL in relation to that matter.

Any claim relating to the accuracy of the Report, in the form of errors or omissions is limited to the failure on the part of FCHL to follow the Standards of Practice of the New Zealand Standard; NZS 4306:2005 Residential Property Inspection (a copy can be made available for viewing if required).

Except in the case of an emergency, the customer further agrees not to disturb, repair, replace or alter anything that may constitute evidence relating to the dispute or claimed discrepancy before FCHL has had an opportunity to re-inspect and investigate the claim. The Customer understands and agrees that any failure to notify FCHL or permit FCHL to re-inspect as stated above shall be deemed to be a waiver of the customer’s rights to continue with and/or make any future claim against FCHL in relation to that matter.

Limitation of Liability

The customer acknowledges and agrees that the director(s) and employee(s) of FCHL shall not be held liable to the customer.

FCHL shall have no liability to the customer for any indirect or consequential loss of whatever nature suffered by the customer or any other person and the customer hereby indemnifies FCHL in respect of any claims concerning any such loss.

Subject to any statutory provisions, if FCHL becomes liable to the customer for any reason, for any loss, damage, harm or injury in any way connected with the completion of the inspection and/or the Report, FCHL’s total liability shall be limited to a sum not exceeding $5,000.

Consumer Guarantees Act

Nothing contained in these terms and conditions shall be deemed to exclude or restrict any rights or remedies that the customer may have under the Consumer Guarantees Act 1993 or otherwise at law. Partial Invalidity

If any provision in these terms and conditions is illegal, invalid or unenforceable, such provision shall be deemed to be excluded or read down to the extent necessary to make the provision legal, valid or enforceable, and the remaining provisions of these terms and conditions shall not be affected.

“All our building inspections and reports are subject to our standard terms and conditions. This is an important legal document. Please take the time to read it before ordering any inspection or other services. Our standard terms and conditions exclude certain types of liability and limit our total liability to customers in the event of any problems.”

Page 28: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 28

FUTURE ISSUES A MUST READ

Recent court rulings as to how building and moisture inspections are reported are now required.

The rulings apply to all buildings not compliant with current codes.

This means if a building was compliant at the time of construction but methods materials along with flashings

and a new building code has changed since this dwelling was constructed. Inspectors must report on future

potential issues that are likely to adversely affect the buildings future durability in those areas in which the

specification has now been upgraded.

This is done regardless if there were no issues found on the day of inspection.

Should future issues occur they are more likely to happen around areas described as a high risk.

Most of these areas are proven to be flashings around windows and doors, internal guttering, eaves, external

fittings such as lighting, joins in sheets which crack and parapet capping’s

FCHIL advises that if moisture or building inspection was satisfactory on the day of inspection but the dwelling

was built prior to the current building code the following may occur.

Flashings around windows and doors. Current code ensures that if moisture gains access for whatever reason it

can get out without damaging the timber. Prior to the current codes, inspections of flashing installation and the

installation themselves were varied and sometimes unsatisfactory.

The guarantee therefore that if moisture gets in it can get out cannot be given for houses not currently

compliant. To minimize this risk it is recommended a yearly maintenance check to ensure there is no increased

moisture levels. FCHL past experience tells us that, should moisture levels rise it is in most cases due to the

comer miter join seals beginning to fail or the seal between the window cladding has broken.

These areas are easy to fix

Internal Guttering: If internal guttering becomes blocked and there are no insufficient overflows, water can

build up quickly and backflow into the soffit which fills up and then may flow into the frame. If there is no soffit

it may back flow directly into the frame. It is therefore essential that internal guttering is checked regularly for

blockages. Where there is internal guttering and a soffit, a simple fix is to install grills every 2 meters. This allows

any back flow that enters the soffit to exit via the grills before it reaches the frame.

Cladding Joins: Any cracks that appear increase the risk of moisture entering the frame. All cracks should be

raked and sealed.

Eaves: Eaves provide limited protection to exterior cladding, the windows and doors. As the size of the soffit

decrease, the risk of moisture entry increases because the water reaches the cladding, windows and doors more

often. In addition, if driving rain has forced water under the tiles or parapet flashing, it may enter the frame. In

the case of minimal eaves, the best protection is organising a method to prevent wind from forcing rain upwards

and ensuring regular maintenance around windows and doors and repairing cracks as they may show.

Page 29: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 29

Parapets: Where a building has parapets, they should be capped. If there is no capping the material used to

encase the frame may crack over time and allow moisture to enter the frame. A capping, usually metal, affords

good protection. The sides of the capping can lift under high winds allowing water to enter the top. If the top is

cracked, the water may then enter the frame. The fix is to regularly cast a visual eye to ensure no lifting of the

skirt and if so, arrange for it to be realigned and resealed.

Exterior Lights: The holes through which the cables pass to the external lights should be sealed. Water running

down the wall can pool inside the light fitting. When it’s sufficiently high it can reach the cable hole and flow

into the frame. The fix is to take down the lights, check the holes are sealed then replace. The screws used to

face the lights to the wall should be bound with silicon before replacing the unit.

Page 30: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 30

SUMMARY LIST OF FEATURES INSPECTED For any feature not present on the property, mark as N/A (not applicable).

Inspected

Y N N/A

SITE

Orientation of living spaces y

Site exposure, contour & vegetation y

Retaining walls y

Paths, steps, handrails & driveways y

Fencing y

Surface water control y

SUB

FLO

OR

Location of access point y

Accessibility y

Foundation type & condition y

Foundation walls y

Ground condition y

Ground vapour barrier y

Drainage y

Ventilation adequacy y

Pile type, instability & condition y

Pile to bear connections y

Obvious structural alteration y

Ground clearance of timber framing y

Floor type (timber or suspended concrete) y

Timber framing & bracing y

Insulation type, appropriate thickness, coverage & condition

y

Plumbing – material types, leakage & support y

Electrical – wiring type & support y

Insect and pest infestation y

Rotting timbers y

Debris y

EXTE

RIO

R Construction Type y

Cladding y

Chimneys n

Exterior stairs n

Balconies, verandahs, patios, etc. y

RO

OF

Roof material y

Roof condition y

Roof water collection y

Downpipes y

Eaves, fascia & soffits y

Y N N/A

INTE

RIO

R

Ceilings y

Walls y

Timber floors y

Concrete floors y

Doors & frames y

Electrical – operation of switches, etc. y

Heating systems y

Kitchen Bench top y

Cabinetry y

Sink y

Tiles y

Air extraction system y

Bathroom, WC, Ensuite y

Floor y

Cistern, pan & bidet y

Tiles y

Bath y

Shower y

Vanity/washbasin y

Ventilation y

Special features y

Laundry Location y

Floor y

Tubs/cabinet y

Tiles y

Ventilation y

Storage y

Stairs y

Exterior windows & doors y

SER

VIC

ES

Fire warning & control systems y

Heating systems y

Central vacuum systems n

Ventilation systems n

Security system n

Electricity services y

Gas services n

Water services y

Hot water services y

Foul water disposal y

Grey water recycling system n

Rainwater collection systems y

Solar heating n

Aerials & antennae n

Shading systems y

Telecommunications n

Lifts n

AN

CIL

LAR

Y S

PA

CES

Exterior claddings y

Floors y

Roofs y

Sub Floor y

RO

OF

SPA

CE

Accessibility y y

Roof cladding y

Thermal insulation type, clearances, approximate thickness & coverage

y n

Sarking n

Party walls, fire proofing n

Roof underlay & support y

Roof frame construction & connections y

Ceiling construction y

Obvious structural alteration y

Insect and pest infestation y

Rotting timbers y

Discharges into roof space y

Plumbing – material types, leakage & support y

Electrical – wiring type & support y

Tile fixings n

Inspected

Page 31: House Inspection Specialists Sum Insured Home Rebuild Cost … · 2014. 6. 27. · House Inspection Specialists Sum Insured Home Rebuild Cost Appraisals Pre Purchase Inspections Mobile:

Page 31

Ref No…501………..

CERTIFICATE OF INSPECTION IN ACCORDANCE WITH NZS 4306 2005

Client: Mr & Mrs Smith

Site address: 123 Sample St Auckland

Inspector:

Name: Mark Muller

Company: FCHI

Qualifications: Builder

Date of inspection: 10/04/2014

The following areas of the property have been inspected:

Yes No

(please tick)

(a) Site y

(b) Subfloor y

(c) Exterior y

(d) Roof Exterior y

(e) Roof Space y

(f) Interior y

(g) Services y

(h) Accessory units, ancillary spaces and buildings y Any limitations to the coverage of the inspection are detailed in the written report. Certification: I hereby certify that I have carried out the inspection of the property site at the above address in accordance with NZS 4306 2005 Residential Property Inspection – and I am competent to undertake this inspection.

Signature:

Date:10/04/2014

An inspection carried out in accordance with NZS 4306 2005 is not a statement that a property complies with the requirements of any Act, regulation or bylaw, nor is the report a warranty against any problems developing after the date of the property report. Refer to NZS 4306 2005 for full details.