Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

23
Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration

Transcript of Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Page 1: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Host System and FT | JAN 2 0 1 3

Fault Tolerant Configuration

Page 2: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

• Host System Software – LiNC-NXG, LiNC-Plus, LiNC-XS, EBI*

• Fault Tolerant Architecture– FTC Controllers– Door Modules

• Dual Door Module (DDM)

– Single Door Module (SDM)

• Ethernet Communication• Up to 3 Communication Ports

– Ethernet– PoE – XBee PRO DigiMesh

Fault Tolerant System Architecture

Page 3: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

• Fault Tolerant Controller (FTC)– Distributed Intelligent Controllers with Hydra

• Door Modules– DDM series (Dual Door Module)

• Any Reader or Biometric Type• Supervised Reader Detect

– SDM (Single Door Module)• Single Door controller (No reader)

– SDM ER series• All inclusive (Multi-Tech Reader and Controller)

Controller Components

Page 4: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Basic Fault Tolerant Archtecture

Ethernet Network

Page 5: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

FT Configuration – “CLIQUE”

• A Clique is a “group” of Fault Tolerant Controllers and Door Modules– Maximum 8 – Fault Tolerant Controllers– Maximum 112 – Door Modules (DDM/SDM)

• Up to 224 readers

• A Clique Communicates Information within itself and to the Host

• No limit to the number of Cliques per system

Page 6: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Design Recommendations

• Fault Tolerant Controller Capabilities– Monitor and Control up to 16 DDM or SDM

• Clique Size– Up to 8 FTC– Total 112 door control modules

• Up to 224 readers if all controllers are DDM

Page 7: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Typical Enterprise Network Application

Clique 1

Clique 4 Clique "n"

Clique 2

Clique 3

Page 8: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Basic Door Architecture

Fingerprint Reader with RFID Reader

RFID Readerwith Keypad

DDM

Reader Cable Requirements to the Door:

6 conductor, 22 AWG, Stranded with overall Shield. Fingerprint Reader will require its own power cable(2 conductor, 18 AWG, stranded).

Motion DetectorEthernet

Battery Output

Page 9: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Door Installation Configuration A

Non Secured Side Secured Area

REXButton

Door Strike

Door Status

CardReader

Page 10: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Secured Area

PIR(REX)

Door Strike

Door Status

CardReader

Magnetic Door Lock

Door Installation Configuration B

Non Secured Side

Page 11: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Door Installation Configuration C

Non Secured Side Secured Area

Card Reader

Door Strike

Door Status

CardReader

Page 12: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Typical DDM Cable Connections

To Network Switch

Reader

REX

Door Lock

2 Conductor 18 AWG Stranded

2 Conductor 22 AWG Stranded

CAT 5 or 6 Cable

6 Conductor 22 AWG, Stranded

DDM

Page 13: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Door Connections for ALL PCSC Products

Wiegand Reader Connection

REX

Door Status

Door LockDoor Lock

N.C.N.O.

Common

Door Connections

Page 14: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Single Door Module (SDM)

SDM ERP40

Page 15: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

• SDM– Single Door Controller– PoE Communication– Any Wiegand Card Technology or Biometric

Reader– Door Status, REX, Door Lock Output

• SDM “ER” series– Same as Above– Incorporated Reader

• Proximity• Multi-Technology

Single Door Module Configurations

Page 16: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Single Cable Installation—SDM ER Series

Controller • Ethernet or PoE• Door Lock Output• Door Sense Input• Request to Exit (REX)• Power Input

Reader - Incorporated

• Proximity• Multiclass

Page 17: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Single Cable Application—SDM ERP

Door Lock

Door Status

To PoE Switch

SDM

Page 18: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

SDM—Controller ONLY

To PoE Switch

SDM

Reader

Lock

Door Status

Page 19: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Multi-Tenant Application

Page 20: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Legacy System Upgrade Requirements

• Latest System Software– LiNC-NXG, LiNC-Plus, LiNC-XS, EBI

• Supported Legacy Controllers– IQ, SIM, ULT series controllers

• Upgrade Controller Communications– LANU– Terminal Servers

Page 21: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Fault Tolerance Architecturewith Legacy Controllers

Page 22: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.

Application Solutions with Fault Tolerant

• Commercial High Rise • Enterprise Systems• Remote Managed Access• Campus Environment• Industrial• Banking• Government, HSPD compliant Cards• High Reliability• High Security Requirements

Page 23: Host System and FT | JAN 2 0 1 3 Fault Tolerant Configuration.