LYNX Touch Series Control Quick Installation Guide This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults. FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech (see LYNX Touch Series Installation and Setup Guide P/N 800-10614 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell. WARRANTY INFORMATION For the latest warranty information, please go to: www.honeywell.com/security/hsc/resources/wa 1. Install the Control TERMINAL STRIP POWER SUPPLY RECEPTACLE BACK CASE TAMPER SWITCH TELEPHONE CONNECTIONS EDGE CONNECTOR WIRE ROUTING CLIPS (3) MOUNTING HOOKS (HINGES) 5100-100-078-V0 LOCKING TABS FRONT CASE ROTATE FRONT CASE UPWARD TO RELEASE HOOKS EDGE CONNECTOR GSMVLP5-4G/ILP5 RECEPTACLE ILP5 RECEPTACLE KNOCKOUT ILP5 SPACER BATTERY CABLE CHANNEL TIE WRAP POINTS (3) MOUNTING HOLES (4) TIE WRAP POINTS (2) INSTALL SCREW IN CASE TAMPER CASE TAMPER DETAIL A 2. Make Wiring Connections 5100-100-076-V0 2K OHM EOLR POWER SUPPLY CONNECTOR HARD WIRED ZONE WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM PREMISES TELEPHONE INCOMING PHONE LINE INCOMING PHONE LINE H/S T H/S R RING TIP EGND EARTH GROUND HWZ1 TRIG GND GND +9VDC 300-04705 or 300-04605 (300-04063 CANADA) POWER SUPPLY 9V, 2.7A STANDARD CAPACITY BATTERY CONNECTORS SUPER HIGH CAPACITY BATTERY CONNECTOR ZONES POWER PHONE EDGE CONNECTOR (L5100-ZWAVE) EDGE CONNECTOR (L5100-WiFi) TRIGGER OUTPUT (NEG) (3ma) RING TIP RING TIP TELCO JACK UL NOTE THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE #26 GAGE OBSERVE POLARITY WHEN CONNECTING THE POWER SUPPLY TO THE TERMINAL STRIP. WARNING TO PREVENT RISK OF SHOCK, DISCONNECT TELEPHONE LINE AT TELECOM JACK BEFORE SERVICING THIS UNIT NOTE USE ONLY THE 300-04705/300-04605 OR 300-04063 POWER SUPPLY PROVIDED ALL OUTPUT CIRCUITS ARE POWER LIMITED. GSMVLP5-4G/ILP5 RECEPTACLE Note: For the complete Summary of Connections, refer to the LYNX Touch Series Installation and Setup Guide P/N 800-10614 or higher. 3. Install the Communications Module SIM CARD 5100-100-077-V0 ROTATED 180 ROTATED 180 CONNECTOR BOARD CONNECTOR BOARD CONNECTOR BOARD RECEPTACLE LYNX TOUCH TIE WRAP POINT NOTE: SIM CARD INSTALLED IN GSMVLP5 ONLY REMOVE ILP5 SPACER ILP5 SPACER REMOVE ILP5 KNOCKOUT TIE WRAP (1) LYNX TOUCH ALTERNATE INSTALLATION RJ45 RECEPTACLE RJ45 RECEPTACLE ETHERNET CABLE GSMVLP5-4G SCREW (3) ILP5 TO ILP5 Ensure that SIM card and the connector board are securely installed in the communications module before installing it in the LYNX Touch. 4. Make Battery Connections 5000-100-018-V1 LYNXRCHKIT-SHA (P/N 300-03866) OR RETAINER SCREW RETAINER LYNXRCHKIT-SC (P/N 300-03864-1) SCREW 1. Release the front case from the rear case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver. 2. Separate the front and back case assemblies by rotating the front case so that it is perpendicular to the rear case and unsnapping (releasing) the two hooks (hinges) from the back case. 3. Feed the wiring through the appropriate openings in the back case. Use tie wraps to secure the wiring to the built-in wire loops as needed. 4. Mount the back case to a sturdy wall and secure with the provided screws. 5. If required, install an additional mounting screw in the case tamper (see Detail A). 6. Attach the front and back cases by connecting the hooks on the front case to the attachments on back case. Once attached, the hooks will support the front case and allow you to make the wiring connections. 7. After all of the wiring connections have been made, snap the front case and back case closed and ensure that the locking tabs secure the case. 1. Make earth ground connections to EGND terminal. 2. Connect the incoming phone line to either the 8-position jack or the TIP and RING terminals. 3. Connect the handset phone lines to the H/S T (TIP) and H/S R (RING) terminals. Note: For full line seize operation, refer to the LYNX Touch Series Installation and Setup Guide. 4 Connect the sensors/contacts to the HWZ1 (+) and GND (-) terminals. 5. If used, install the GSMVLP5-4G or ILP5 communications module Refer to the Install the Communications Module section or to the Installation Guide for the Communications Module (P/N 800- 01115 or higher). 6. Connect wires from the 300-04705/300-04605 OR 300-04063 (Canada) Power Supply to GND (-) and +9VDC (+) terminals OR plug the Power Supply connector into the receptacle on the LYNX Touch. 1. If you are installing the ILP5 module, use a wire cutter or knife to cut the plastic tabs that secure the ILP5 spacer to the back case of the LYNX Touch. If you are installing the GSMVLP5-4G module, proceed to step 3. 2. Remove the ILP5 receptacle knockout from the left side of the LYNX Touch back case 3 Install the Communications Module into the front case. Ensure that the connector board is properly seated into the receptacle on the control. 4 Secure the module with the three provided screws. If you are installing the ILP5 module, proceed to step 5. If you are installing the GSMVLP5-4G module, proceed to step 8 5. Insert the ILP5 receptacle and spacer into the slot on the back case. 6. Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap. 7. Connect the Ethernet cable to the RJ45 receptacle. 8. Enable the module, configure alarm reporting and module supervision and register the device. Refer to the “Communications Diagnostics” section of the LYNX Touch Installation Guide (P/N 800-10614 or higher). 1. Remove screw securing the battery retainer. 2. Remove the battery retainer. 3. Insert battery pack into back case. 4. Install battery retainer. 5. Install screw to secure the battery retainer. 6. Connect battery connector to receptacle on PC board. 7. After all wiring connections have been made, snap the front case to the back case so it is held by the locking tabs. 8. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet. Note: Rechargeable batteries may take up to 48-hours to fully charge. “Battery Low” message should clear within four hours, or by entering Test Mode. Battery Part Number Battery Standby Time (Minimum) Low Battery Notification LYNXRCHKIT-SC (300-03864-1) 4-hours Approx. 1-hour before battery depletion LYNXRCHKIT-SHA (300-03866) 24-hours At least 1-hour before battery depletion Ê800-110599Š 800-11059 2/12 Rev. A 2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 Copyright © 2012 Honeywell International Inc. www.honeywell.com/security

description

Honeywell L5100 LYNX Touch Wireless Alarm Control Panel http://www.alarmgrid.com/products/honeywell-l5100Alarm Grid Home Security http://www.alarmgrid.com/ has provided this pdf with the permission and courtesy of Honeywell. Alarm Grid is an alarm monitoring company with an emphasis on affordable alarm monitoring, great customer service, and diy consumers interested in building their own home security systems. If you are looking for a home security system, a business security system, or an alarm system for your apartment or condo, let us guide you through the process of purchasing the equipment that is right for your space, and the monitoring that is right for your equipment.

Transcript of Honeywell l5100 Quick Install Guide

Page 1: Honeywell l5100 Quick Install Guide

LYNX Touch Series Control Quick Installation Guide This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults. FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech (see LYNX Touch Series Installation and Setup Guide P/N 800-10614 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell.

WARRANTY INFORMATION For the latest warranty information, please go to:

www.honeywell.com/security/hsc/resources/wa

1. Install the Control

TERMINALSTRIP

POWERSUPPLYRECEPTACLE

BACKCASE

TAMPERSWITCH

TELEPHONECONNECTIONS

EDGECONNECTOR

WIRE ROUTINGCLIPS (3)

MOUNTINGHOOKS

(HINGES)

5100-100-078-V0LOCKING TABS

FRONTCASE

ROTATEFRONT CASE

UPWARDTO RELEASE

HOOKS

EDGECONNECTOR

GSMVLP5-4G/ILP5RECEPTACLE

ILP5 RECEPTACLEKNOCKOUT

ILP5SPACER

BATTERYCABLE CHANNEL

TIE WRAPPOINTS (3)

MOUNTINGHOLES (4)

TIE WRAPPOINTS (2)

INSTALLSCREW

IN CASETAMPER CASE

TAMPER

DETAIL A

2. Make Wiring Connections

5100-100-076-V0

2KOHMEOLR

POWER SUPPLYCONNECTOR

HARDWIREDZONE

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM

PREMISESTELEPHONE

INCOMINGPHONE LINE

INCOMINGPHONE

LINE

H/S

T

H/S

R

RIN

G

TIP

EG

ND

EARTHGROUND

HW

Z1

TR

IG

GN

D

GN

D

+9V

DC

300-04705 or 300-04605(300-04063 CANADA)

POWER SUPPLY9V, 2.7A

ST

AN

DA

RD

CA

PA

CIT

YB

AT

TE

RY

CO

NN

EC

TO

RS

SU

PE

R H

IGH

CA

PA

CIT

YB

AT

TE

RY

CO

NN

EC

TO

R

ZONES POWERPHONE

EDGE CONNECTOR(L5100-ZWAVE)

EDGE CONNECTOR(L5100-WiFi)

TR

IGG

ER

OU

TP

UT

(N

EG

)(3

ma)

RINGTIP RING TIP

TELCOJACK

UL NOTETHE MINIMUM WIRE SIZE USED FOR TELEPHONE

INSTALLATIONS MUST BE #26 GAGE

OBSERVE POLARITY WHENCONNECTING THE POWER

SUPPLY TO THE TERMINAL STRIP.

WARNINGTO PREVENT

RISK OF SHOCK,DISCONNECT

TELEPHONE LINEAT TELECOM

JACK BEFORESERVICINGTHIS UNIT

NOTEUSE ONLY THE

300-04705/300-04605OR 300-04063

POWER SUPPLYPROVIDED

ALL OUTPUT CIRCUITS ARE POWER LIMITED.

GSMVLP5-4G/ILP5RECEPTACLE

Note: For the complete Summary of Connections, refer to the LYNX Touch Series Installation and Setup Guide P/N 800-10614 or higher.

3. Install the Communications Module

SIM CARD

5100-100-077-V0

ROTATED180

ROTATED180

CONNECTORBOARD

CONNECTOR BOARD

CONNECTOR BOARD

RECEPTACLE

LYNX TOUCH

TIEWRAPPOINT

NOTE:SIM CARD INSTALLEDIN GSMVLP5 ONLY

REMOVEILP5

SPACERILP5

SPACER

REMOVEILP5

KNOCKOUT

TIEWRAP

(1)

LYNX TOUCH

ALTERNATE INSTALLATION

RJ45RECEPTACLE

RJ45 RECEPTACLE

ETHERNET CABLE

GSMVLP5-4GSCREW

(3)

ILP5

TO ILP5

Ensure that SIM card and the connector board are securely installed in the communications module before installing it in the LYNX Touch.

4. Make Battery Connections

5000-100-018-V1

LYNXRCHKIT-SHA(P/N 300-03866)

OR

RETAINER

SCREW

RETAINER

LYNXRCHKIT-SC(P/N 300-03864-1)

SCREW

1. Release the front case from the rear case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver.

2. Separate the front and back case assemblies by rotating the front case so that it is perpendicular to the rear case and unsnapping (releasing) the two hooks (hinges) from the back case.

3. Feed the wiring through the appropriate openings in the back case. Use tie wraps to secure the wiring to the built-in wire loops as needed.

4. Mount the back case to a sturdy wall and secure with the provided screws.

5. If required, install an additional mounting screw in the case tamper (see Detail A).

6. Attach the front and back cases by connecting the hooks on the front case to the attachments on back case. Once attached, the hooks will support the front case and allow you to make the wiring connections.

7. After all of the wiring connections have been made, snap the front case and back case closed and ensure that the locking tabs secure the case.

1. Make earth ground connections to EGND terminal. 2. Connect the incoming phone line to either the 8-position jack or

the TIP and RING terminals. 3. Connect the handset phone lines to the H/S T (TIP) and H/S R

(RING) terminals. Note: For full line seize operation, refer to the LYNX Touch Series

Installation and Setup Guide. 4 Connect the sensors/contacts to the HWZ1 (+) and GND (-)

terminals. 5. If used, install the GSMVLP5-4G or ILP5 communications module

Refer to the Install the Communications Module section or to the Installation Guide for the Communications Module (P/N 800-01115 or higher).

6. Connect wires from the 300-04705/300-04605 OR 300-04063 (Canada) Power Supply to GND (-) and +9VDC (+) terminals OR plug the Power Supply connector into the receptacle on the LYNX Touch.

1. If you are installing the ILP5 module, use a wire cutter or knife to cut the plastic tabs that secure the ILP5 spacer to the back case of the LYNX Touch. If you are installing the GSMVLP5-4G module, proceed to step 3.

2. Remove the ILP5 receptacle knockout from the left side of the LYNX Touch back case

3 Install the Communications Module into the front case. Ensure that the connector board is properly seated into the receptacle on the control.

4 Secure the module with the three provided screws. If you are installing the ILP5 module, proceed to step 5. If you are installing the GSMVLP5-4G module, proceed to step 8

5. Insert the ILP5 receptacle and spacer into the slot on the back case.

6. Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap.

7. Connect the Ethernet cable to the RJ45 receptacle. 8. Enable the module, configure alarm reporting and module

supervision and register the device. Refer to the “Communications Diagnostics” section of the LYNX Touch Installation Guide (P/N 800-10614 or higher).

1. Remove screw securing the battery retainer. 2. Remove the battery retainer. 3. Insert battery pack into back case. 4. Install battery retainer. 5. Install screw to secure the battery retainer. 6. Connect battery connector to receptacle on PC board. 7. After all wiring connections have been made, snap the front case

to the back case so it is held by the locking tabs. 8. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet. Note: Rechargeable batteries may take up to 48-hours to fully

charge. “Battery Low” message should clear within four hours, or by entering Test Mode.

Battery

Part Number Battery Standby Time (Minimum) Low Battery Notification

LYNXRCHKIT-SC (300-03864-1) 4-hours Approx. 1-hour before

battery depletion

LYNXRCHKIT-SHA (300-03866) 24-hours At least 1-hour before

battery depletion

Ê800-110599Š 800-11059 2/12 Rev. A

2 Corporate Center Drive, Suite 100P.O. Box 9040, Melville, NY 11747

Copyright © 2012 Honeywell International Inc.www.honeywell.com/security

Page 2: Honeywell l5100 Quick Install Guide

Programming Notes Entering Installer Programming mode 1. Power-up the control and select the “more” tab on the first

page of the Home Screen. 2. Select “Tools” button. 3. Enter the 4-digit Installer Code (4-1-1-2). 4. Select “Program” button. 5. The System Programming Screen will appear and the

“Armed” and “Ready” LEDs will flash.

Exiting Programming mode 1. Once programming is completed, at the System Programming

screen, select the “!” button. 2. Select the “Yes” when the system prompts “Allow Installer to

Re-Enter Programming?”. 3. Select the “!” button to return to the Home Screen.

Entering Master User Programming mode 1. Power-up the control and select the “more” tab on the first

page of the Home Screen. 2. Select “Tools” button. 3. Enter the 4-digit Master User Code (1-2-3-4). 4. The Master User Programming Screen will appear and the

“Ready” LED will remain lit. 5. Select the applicable programming function from the Master

User screen.

Exiting Programming mode 1. Once programming is completed, select the “back” tab to

return to the Home Screen. OR 2. Depress the “Off” key and then select the “Cancel” button. 3. The system will return to the Home Screen.

5. Program the Control Change the Installer Code The factory default Installer Code for the LYNX Touch Series Control is set to 4-1-1-2. To change this code, you must enter Programming mode. 1. Select “Program” button. 2. Select “Installer Code” button. 3. Enter a new 4-digit Installer Code. 4. Select “Done” button

Program Date Note: If you are installing a GSMVLP5-4G or ILP5 Communication

Module, the time and date will be programmed and updated automatically via Central Station. You must still program the correct Time Zone

To change this code, you must enter Programming mode. 1. Select “Program” button. 2. Select “Date Time” button. 3. Enter the date, time and time zone as required. 4. Select “Save” button.

Program Defaults LYNX Touch is pre-programmed at the factory with a built-in set of default values. Refer to the Programming Default Tables section of the LYNX Touch Series Installation and Setup Guide (P/N 800-10614 or higher) to view the Default Tables. To select factory defaults from a set of four tables, you must enter Programming mode. 1. Select “Program” button. 2. Select “Default Config.” button. 3. Select the desired Default Table. 4. Select “Yes” when the confirmation screen appears.

6. Add Wireless Sensors Add a Sensor To add, edit or delete Wireless Sensors you must enter Programming Mode. 1. Select “Zones” button. 2. Select “’Add new” button. 3. Select the applicable Zone button. 4. Select “Serial Number” Button 5. Enter Serial Number or Enroll via RF Learning. To enroll the

transmitter, three (open/close) transmissions of the device will be required.

6. If desired, program the following options: Loop Number Zone Description 1 and 2 Device Type Response Type Alarm Report Chime Supervision

7. Select “Save”.

Edit Wireless Sensor/Zone information 1. Select “Zones” button. 2. Select the Zone you wish to edit and then select the “Edit” button. 3. Edit the applicable zone programming fields as required. 4. Select “Save”.

Delete a Wireless Sensor 1. Select “Zones” button. 2. Select the Zone you wish to delete then select the “Delete” button. 3. Select the “Yes” button when the confirmation screen appears.

6. Add Wireless Keys To add, edit or delete a Wireless Key you must enter Programming Mode.

Add a Wireless Key 1. Select “Keys” button. 2. Select ’Add New” button. 3. Select the “Key Type” button and scroll through the available key

types. 4. Select “Serial Number” Button 5. Enter Serial Number or Enroll via RF Learning. To enroll the

transmitter, three (open/close) transmissions of the device will be required.

6. Select the “User” button and then select the User that will be associated with the key that is being enrolled.

Note: In order for the Key to function, a valid User Code must be associated with the User that has been assigned to the key.

7. If desired, program the following options: Zone Button Key * - Zn **

8. Select “Save”. * Button number is determined by the type of key being enrolled. ** Zn No. based on the type of key being enrolled.

Edit Wireless Key information 1. Select “Keys” button. 2. Select the Key you wish to edit and then select the “Edit” button. 3. Edit the applicable fields as required 4. Select “Save”.

Delete a Wireless Key 1. Select “Keys” button. 2. Select the Key you wish to delete then select the “Delete” button. 3. Select the “Yes” button when the confirmation screen appears.

7. Add Central Station Accounts To add Central Station Account information, you must enter Programming Mode.

Add First or Second Central Station Information 1. Select the “Reporter” button. 2. Select the “Primary CS Info” or “Secondary CS Info” button. 3. Program the following fields as applicable:

Phone Type Phone Number Communicator Type Account Number Dynamic Priority Dynamic Delay Report All Report Alarms Report Troubles Report Open/Close Report Tests

4. Select the “Save” button when programming is complete.

All four digits of the Central Station Account numbers must be entered. For ten-digit format, all ten digits must be entered. Refer to the LYNX Touch Series Installation and Setup Guide for additional information regarding these programming options.

8. Register the Communications Module The Communications Module can be registered either via the AlarmNet Direct Website, by Phone or through the LYNX Touch Diagnostics. For additional information on the first two methods refer to the LYNX Touch Installation and Setup Guide P/N 800-10614 or higher.

Register through LYNX Touch Diagnostics To Register the Communications Module, you must enter Programming Mode. 1. Select the “Comm. Diagnostics” button. 2. Select the “Setup Communications” button. 3. Select the “Register Device” button. The registration message is

sent and the unit waits for the acknowledgement. (Refer to the LYNX Touch Installation and Setup Guide P/N 800-10614 or higher for additional information)

9. Program User Functions To perform these functions, you must enter the Master User Programming mode. Add Users 1. Select the “Users” button. 2. Select the “Add New” button. 3. Enter a User Name. 4. Enter a 4-digit User Code. 5. Select “Done”.

Change the Master User Code 1. Select the “Users” button. 2. Select the “Master” button. 3. Select the “Edit” button. 4. Enter a new 4-digit User Code. 5. Select “Done”.

Change/Edit Users or User Codes 1. Select the “Users” button. 2. Select the applicable “User” button. 3. Select the “Edit” button. 4 Revise the User name, if applicable, then select the “Done”

button. 5. Enter a new 4-digit User Code, if applicable, then select the “Done”

button.

Delete User Codes 1. Select the “Users” button. 2. Select the applicable “User” button. 3. Select the “Delete” button. 4. Enter a new 4-digit User Code. 5. Select “Yes” when the confirmation screen appears.

10. Test the system To perform this function, you must enter the Installer OR Master User Programming mode. 1. Select the “Test” button or icon. 2. Select the “Walk Test” button or icon. 3. Open each protected door and listen for three beeps from the

keypad, followed by the zone’s Voice Descriptor. Identification of each faulted protection point should appear on the display, and clear when the door is closed.

4. Walk in front of the motion sensor and listen for three beeps and the zone’s voice descriptor.

5. When testing is complete, enter an OFF sequence. 6. Press each key on the key fob to confirm it performs its assigned

function. Note: Refer to the Lynx Touch Series User Guide P/N 800-10615 or

higher for additional information.