777 Rustic Lane, Mountain View February 13, 2018 Home Inspection Report Debbie Blackwell 777 Rustic Lane Inspected by: Ordered by: Paul Salinas HomeGuard Incorporated Mountain View, CA 94040 HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Transcript of HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work...

Page 1: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

777 Rustic Lane, Mountain View

February 13, 2018

Home Inspection Report

Debbie Blackwell

777 Rustic Lane

Inspected by:Ordered by:

Paul Salinas

HomeGuardIncorporated

Mountain View, CA 94040

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 2: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Table of Contents

Report Overview 3

Structure 9

Roofing 10

Exterior 11

Electrical 13

Heating System 15

Cooling/Heat Pump System 16

Insulation/Ventilation 17

Plumbing 18

Interior 20

Photographs 23

Maintenance Advice 26

Page 2 of 27777 Rustic Lane, Mountain View

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 3: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 3 of 27777 Rustic Lane, Mountain View

Report Overview

A GENERAL DESCRIPTION OF THE STRUCTURE

This is an average quality one story single family residence. Approximately 43 years old. Ongoing maintenance is

required and improvements to the systems of the home will be needed over time. The improvements that are

recommended in this report are not considered unusual for a home of this age and location. Please remember that there is

no such thing as a perfect home.

! - IMMEDIATE RECOMMENDED IMPROVEMENTS

The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term.

Other significant improvements, outside the scope of this inspection, may also be necessary. Please refer to the body of

this report for further details on these and other recommendations. No relative importance should be placed on the

photographs provided in this report. The photographs in this report do not necessarily illustrate all of the damage in any

particular finding. Also, not all problem areas will be supported by photographs. If more than one photograph is available

for a particular item, additional photographs can be found at the end of the report in the section entitled 'Photographs'.

Please contact HomeGuard if you have any questions.

WEATHER CONDITIONS

Dry weather conditions prevailed at the time of the inspection.

Roofing

Leaks were noted in the downspouts and/or gutters at the rear. During wet

weather conditions these areas are more obvious and during dry weather

conditions they are noted from the stains at the areas where the leaks have

occurred. We recommend all leaks be repaired. (See Illustration 4B) (See Photo

5)

1.

Photo 5

Exterior

Personal storage was blocking access to the interior of the garage. Therefore,

the area is considered inaccessible and was not fully inspected. With access

and an opportunity for complete inspection, conditions in need of attention may

be discovered. Ideally, the personal belongings should be removed so the area

may be inspected. (See Photo 9)

2.

Photo 9

The cracked and heaved sections of driveway present a trip hazard. This

condition should be corrected for improved safety. (See Photo 1)

3.

Photo 1

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 4: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 4 of 27777 Rustic Lane, Mountain View

Exterior

Water damage was observed to the roof eaves/sheathing at the front. We

recommend the services of a licensed general contractor and/or structural pest

control company. (See Photo 2)

4.

Photo 2

Water damage Q observed to the rafters at the rear. We recommend the

services of a licensed general contractor and/or structural pest control company.

(See Photo 6)

5.

Photo 6

Water damage was observed to the fascia at the front. We recommend the

services of a licensed general contractor and/or structural pest control company.

(See Photo 3)

6.

Photo 3

Electrical

Exterior receptacles at the rear are missing a water proof cover plate. We

recommend a exterior approved cover be installed. (See Photo 7)

7.

Photo 7

The damaged/cracked outlet cover plates should be replaced. (See Photo 14)8.

Photo 14

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 5: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 5 of 27777 Rustic Lane, Mountain View

Electrical

There is a long section of conduit installed at various areas that is not

adequately supported and loose. We recommend that all conduit be supported

and secured in accordance with conventional building standards. (See Photo 19)

9.

Photo 19

An exterior outlet at the left side of the wall is faulty or damaged. We

recommend it be replaced. (See Photo 4)

10.

Photo 4

Heating System

The missing furnace air filter should be replaced. This will help keep dust from re-

entering the occupied interior and help keep the blower and duct work clean.

(See Photo 10)

11.

Photo 10

Plumbing

The hall bathroom and master bathroom drains are leaking into the crawl

space. We recommend all leaks be repaired. (See Photo 20)

12.

Photo 20

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 6: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 6 of 27777 Rustic Lane, Mountain View

Plumbing

The water heater vent pipe or hood is loose and exhaust leakage was evident.

This is a potential safety concern that should be addressed. We recommend the

vent and hood be properly installed. (See Photo 18)

13.

Photo 18

The toilet in the hall bathroom and master bathroom are loose and should be

properly re-secured, tightened and caulked. (See Illustration 5B) (See Photo 11)

14.

Photo 11

Interior

The mirror on the front left bedroom closet door is cracked/damaged. We

recommend replacement. (See Photo 13)

15.

Photo 13

The openings in the railing are larger than 4". For improved safety it is

recommended that the railing be altered for an opening of less than 4". (See

Illustration 7B) (See Photo 17)

16.

Photo 17

Cracked shower wall tile in the hall bathroom should be replaced. Water leaking

through non-sealed areas can cause damage. Damage caused by water

seepage cannot be determined by visual observation. (See Photo 12)

17.

Photo 12

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 7: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 7 of 27777 Rustic Lane, Mountain View

Interior

The escutcheons at the master bathroom shower faucet, spout or shower head

are loose. We recommend tightening and/or sealing this trim piece for a better

appearance and to avoid leakage in this area. (See Photo 15)

18.

Photo 15

California law requires that all homes have a State Fire Marshall approved

Carbon Monoxide Detector installed outside of the sleeping quarters and on each

level of the home. At the time of this inspection a Carbon Monoxide Detector

was located. As a carbon monoxide detector was not noted in all of the

recommended locations additional detectors should be installed.

19.

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 8: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 8 of 27777 Rustic Lane, Mountain View

The Scope of the InspectionAll components designated for inspection in the ASHI standards of practice are inspected, except as may be noted in the

"Limitations" section within the report. This inspection will not disclose compliance with regulatory requirements (codes,

regulation laws, ordinances, etc.)

This inspection is visual only. Only a representative sample of the building and system components was viewed. No

destructive testing or dismantling of building components was performed. The strength, adequacy, effectiveness, or

efficiency of any system or components was not determined. Not all recommended improvements will be identified in this

inspection. Unexpected repairs should still be anticipated. This inspection should not be considered a guarantee or

warranty of any kind. The purpose of our inspection is to provide a general overview of the structure reflecting the

conditions present at the time of this inspection. The inspection is performed by visual means only, reflecting only the

opinions of the inspector. Nothing in the report, and no opinion of the inspector, should be construed as advice to

purchase, or to not purchase, the property. It is the goal of this inspection to put the buyer in a better position to make a

buying decision

Our inspection does not address, and is not intended to address, the possible presence of hazardous plants or animals or

danger from known and unknown environmental pollutants such as, but not limited to, asbestos, mold, radon gas, lead,

urea formaldehyde, underground storage tanks, soil contamination and other indoor and outdoor substances, water

contamination, toxic or flammable chemicals, water or airborne related illness or disease, and all other similar or

potentially harmful substances and conditions. This property was not inspected for the presence or absence of health

related molds or fungi. We are neither qualified, authorized nor licensed to inspect for health related molds or fungi. If you

desire information about the presence or absence health related molds, you should contact the appropriate specialist. Be

aware that many materials used in building construction may potentially contain hazardous substances. Furthermore,

other environmental concerns may exist elsewhere. An environmental specialist should be contacted if additional

information is desired about these issues.

PLEASE NOTE: Important disclosure information and other inspection reports may exist. All present and prior

disclosures along with other inspection reports should be reviewed and any adverse conditions and/or concerns that may

not be mentioned in our report should be addressed prior to the close of escrow. Furthermore, there may be conditions

known by the seller that have not been disclosed to us.

Pictures are provided to assist in clarifying some of the findings made in the report. No relative importance should be

placed on these pictures. There are likely to be significant comments that do not have pictures associated with them.

Please read the report thoroughly.

Sections of this building appear to have been remodeled. We recommend consultation with the owner or local municipality

to determine whether the necessary permits were obtained, inspections performed and final signatures received.

BINDING ARBITRATION PROVISION

Any controversy or claim arising out of or relating to the inspection performed by HomeGuard Incorporated shall be settled by

final and binding arbitration filed by the aggrieved party with and administered by the American Arbitration Association (hereafter

referred to as "AAA") in accordance with its Construction Arbitration Rules in effect at the time the claim is filed. The Rules,

information and forms of the AAA may be obtained and all claims shall be filed at any office of the AAA or at Corporate

Headquarters, 335 Madison Avenue, Floor 10, New York, New York 10017-4605. Telephone: 212-716-5800, Fax: 212-716-5905,

Website: http://www.adr.org/. The arbitration of all disputes shall be decided by a neutral arbitrator, and judgment on the award

rendered by the arbitrator may be entered in any court having competent jurisdiction thereof. Any such arbitration will be

conducted in the city nearest to the property that was inspected by HomeGuard Incorporated having an AAA regional office.

Each party shall bear its own costs and expenses and an equal share of the administrative and arbitrators’ fees of arbitration.

This arbitration Agreement is made pursuant to a transaction involving interstate commerce, and shall be governed by the

Federal Arbitration Act, 9 U.S.C. Sections 1-16. THE PARTIES UNDERSTAND THAT THEY WOULD HAVE HAD A RIGHT OR

OPPORTUNITY TO LITIGATE THROUGH A COURT AND TO HAVE A JUDGE OR JURY DECIDE THEIR CASE, BUT THEY

CHOOSE TO HAVE ANY AND ALL DISPUTES DECIDED THROUGH ARBITRATION. BY SIGNING THIS AGREEMENT, THE

PARTIES ARE GIVING UP ANY RIGHT THEY MIGHT HAVE TO SUE EACH OTHER.

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 9: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 9 of 27777 Rustic Lane, Mountain View

Structure

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

There is a condition known as efflorescence on portions of the foundation walls. This fuzzy material is a salt deposit

left when moisture in the foundation evaporates on the inside of the foundation. This indicates an occasional surplus

of moisture on the outside of the foundation. Steps could be taken to improve the exterior drainage (See “Roofing”

section downspout locations for additional comments/recommendations in regard to this condition).

1.

Minor cracks were observed in the foundation walls of the house. This type of cracking usually occurs during the

curing process of the foundation as is typical of most houses. If further information is desired in regards to these

cracks, the appropriate trades should be engaged.

2.

Past repairs have been performed in the crawl space. We recommend consultation with the owners regarding the

extent of the repairs and any permits that may have been obtained and/or signed off.

3.

The soil in this area is considered "expansive" because it expands and contracts with the variations of the moisture

content. This may, in turn, cause movement in the support structure. This movement may cause cosmetic cracking,

sticking doors, etc. Maintaining moisture content is very important along with good site drainage, effective

landscaping and landscape watering is equally important. This will keep the soil form expanding or shrinking

excessively. If desired, information regarding expansive soils could be obtained from a soils engineer.

4.

Structural components concealed behind finished surfaces could not be inspected.•

Only a representative sampling of visible structural components was inspected.•

Furniture and/or storage restricted access to some of the structural components.•

This is a visual inspection to the accessible areas only. Assessing the structural integrity of a building is beyond the scope

of a typical inspection. A certified professional engineer is recommended where there are structural concerns about the

building.

LIMITATIONS:

The sill appeared to be adequately secured (anchor bolts or straps) to the foundation, unless noted otherwise.

Evidence of past repairs and/or modifications have been made to the foundation. The owner may have information about

the repairs or remodeling work, and any permits that were required, obtained and completed.

ITEM DESCRIPTIONS:

Wall/Foundation Structure • Wood Frame

Attic Access Location • Hallway • Attic Method Of Inspection: From the Access

Ceiling Structure • Truss

Roof Structure • Truss

Roof Sheathing • Not Visible

Crawl Space Access • Closet

Foundation • Poured Concrete

Floor Structure • Wood Joist • Wood Columns • Wood Floor Beams • Plywood or Orientated Strand

Board

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 10: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 10 of 27777 Rustic Lane, Mountain View

Roofing

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

Leaks were noted in the downspouts and/or gutters at the rear. During wet weather conditions these areas are more

obvious and during dry weather conditions they are noted from the stains at the areas where the leaks have occurred.

We recommend all leaks be repaired. (See Illustration 4B) (See Photo 5)

! 1.

The chimney does not have a spark arrestor or rain cap. A rain cap and/or screen should be installed on the chimney.

(See Illustration 3I)

2.

Debris was noted inside the gutters at various areas. We recommend the downspouts and gutters be cleaned out.3.

The downspouts discharge water adjacent to the structure. Water should be directed to flow at least 5' feet away from

the building at the point of discharge. The installation of underground drainage where applicable will help control

surface drainage.

4.

This is a visual inspection to the accessible areas only. Roofing life expectancies can vary depending on several factors.

Any estimates on remaining life are approximations only. This assessment of the roof does not preclude the possibility of

leakage. Leakage can develop at any time and may depend on rain intensity, wind direction, ice build up, etc.

LIMITATIONS:

We recommend reviewing a roof inspection report performed by a licensed roof inspector on this structure.

ITEM DESCRIPTIONS:

Roof • Composition shingle • Method of inspection: From The Roof.

Chimney • Masonry • Method of inspection: From The Roof.

Gutters and Downspouts • Metal • Installation Of Gutters/Downspouts: Full • Downspouts Discharge Location:

Above Grade

Illustration 3I Illustration 4B

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 11: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 11 of 27777 Rustic Lane, Mountain View

Exterior

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

The cracked and heaved sections of driveway present a trip hazard. This condition should be corrected for improved

safety. (See Photo 1)

! 1.

Water damage was observed to the roof eaves/sheathing at the front. We recommend the services of a licensed

general contractor and/or structural pest control company. (See Photo 2)

! 2.

Water damage Q observed to the rafters at the rear. We recommend the services of a licensed general contractor

and/or structural pest control company. (See Photo 6)

! 3.

Water damage was observed to the fascia at the front. We recommend the services of a licensed general contractor

and/or structural pest control company. (See Photo 3)

! 4.

The proximity of the tree at various areas of the wall could disrupt drainage pipes, cause mechanical damage to the

exterior of the house or influence the foundation over time. For additional information and recommendations we

recommend appropriate trades be consulted. (See Illustration 8E)

5.

There are minor sized cracks in the exterior stucco that should be patched and sealed as part of preparation for the

next painting. Flexible patching materials are recommended rather than rigid patching compounds.

6.

Obvious repairs and/or modifications have been made to various areas of the exterior walls. The owner may have

information about the original conditions, the repairs or remodeling work and any permits that were required.

7.

The window(s) in the exterior door lack tempered glass (special safety glass that will not shatter). For safety reasons,

we recommend the installation of tempered glass.

8.

MAINTENANCE ITEMS & GENERAL INFORMATION

Due to possible damage occurring to the garage door during testing, the auto reverse mechanism on the overhead

garage door was not tested. We recommend the auto reverse be tested by appropriate trades. Refer to the owner’s

manual or contact the manufacturer for more information. There is a serious risk of injury, particularly to children,

under this condition. Information on garage door openers is available from the Consumer Product Safety

Commission at www.cpsc.gov.

9.

This home was constructed without the use of a weep screed at the base of the stucco. Although this was an

accepted construction method it can allow condensation to build up and not drain properly. For further information we

recommend appropriate trades be consulted

10.

This is a visual inspection to the accessible areas only.

LIMITATIONS:

The exterior of the home shows signs of normal wear and tear for a home of this age and construction.

Personal storage was blocking access to the interior of the garage. Therefore, the area is considered inaccessible and

was not fully inspected. With access and an opportunity for complete inspection, conditions in need of attention may be

discovered. Ideally, the personal belongings should be removed so the area may be inspected. (See Photo 9)

ITEM DESCRIPTIONS:

Lot Topography • Level grade

Driveway • Concrete

Walkway & Sidewalks • Concrete

Retaining Walls/Abutments • None

Fencing/Gates • Wood • Brick

Steps, Porch/Deck • Brick/Pavers • Concrete • Unknown

Fascia, Eaves and Rafters • Wood • Open Rafters

Exterior Walls • Wood Siding • Brick Veneer • Stucco

Windows • Vinyl

Doors • Wood • Sliding Glass

The Swimming Pool Safety

Act

• Not Applicable

Main Garage • Attached

Main Garage Door/Opener • Wood • Automatic Opener Installed

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 12: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 12 of 27777 Rustic Lane, Mountain View

A representative sample of exterior components was inspected.•

The inspection does not include an assessment of geological conditions, site stability and property surface drainage

runoff.•

The detached outbuilding, related equipment and ancillary wiring and plumbing services were not inspected and are

excluded from this report.•

Interior finishes (floors, walls, ceilings) and/or insulation restricted the inspection of the garage.•

Illustration 8E

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 13: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 13 of 27777 Rustic Lane, Mountain View

Electrical

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

The damaged/cracked outlet cover plates should be replaced. (See Photo 14)! 1.

Exterior receptacles at the rear are missing a water proof cover plate. We recommend a exterior approved cover be

installed. (See Photo 7)

! 2.

There is a long section of conduit installed at various areas that is not adequately supported and loose. We

recommend that all conduit be supported and secured in accordance with conventional building standards. (See

Photo 19)

! 3.

An exterior outlet at the left side of the wall is faulty or damaged. We recommend it be replaced. (See Photo 4)! 4.

DISCRETIONARY IMPROVEMENTS AND/OR UPGRADES

The installation of ground fault circuit interrupter "GFCI" devices is advisable on exterior, garage, bathroom and some

kitchen outlets. Any whirlpool or swimming pool equipment should also be fitted with "GFCI"s. A ground fault circuit

interrupter "GFCI" offers protection from shock or electrocution. Please note that "GFCI" may already be in one or

more of these areas. See "description" section above for exact location of any "GFCI" which may be present on this

property. (See Illustration 13A)

5.

Today's electrical standard now requires a device called an arc-fault circuit interrupter "AFCI". As defined in proposals

for the 1999 NEC, an "AFCI" is a device that provides protection from effects of arc faults by recognizing

characteristics unique to arcing, and then de-energizing the circuit upon detection of an arc fault. Its basic application

is protection of 15 amp and 20 amp branch circuits in single and multi-family residential occupancies. These devices

are now installed in the habitable bedrooms of new construction.

6.

Due to inaccessibility of concealed wiring or undocumented improvements of the structure, we are unable to predict

whether the number of circuits within a home will be sufficient for the needs of the occupants during a typical home

inspection. If fuses blow or breakers trip regularly, this may indicate that additional loads or remodeling modifications

may have been added to existing circuits.

Electrical components concealed behind finished surfaces could not be inspected.•

According to "ASHI" standards only a representative sampling of outlets and light fixtures were tested.•

This is a visual inspection to the accessible areas only. The inspection does not include (if applicable) low voltage

systems, telephone wiring, intercoms, alarm systems, TV cable, timers, central vacuum systems, exterior sprinkler

systems, exterior landscape lighting or exterior motion sensor lights. Also smoke detectors out of reach were only visually

inspected unless noted otherwise. We recommend these systems be checked by interested parties for proper operation

when possible.

LIMITATIONS:

The size of the electrical service is sufficient for typical single family needs.

The distribution of electricity within the home is good.

The 3-prong outlets that were tested were appropriately grounded.

Dedicated 240 volt circuits have been provided for all 240 volt appliances within the home.

Inspection of the electrical system revealed the need for minor improvements. A licensed electrician should be consulted

to undertake the improvements recommended below.

ITEM DESCRIPTIONS:

Service • 120/240 volt main service

Service Entrance • Underground Service Wires

Service Ground • Copper Ground Wire

Main disconnect • Breakers • Main Service Rating (Amps): 125

Main Distribution Panel • Breakers • Exterior Side • Panel Rating (Amps): 125

Branch/Auxillary Panel • Breakers • Hallway • Panel Rating (Amps): 125

Distribution Wiring • Copper Wire

Outlets • Grounded

Ground Fault Circuit

Interrupters

• None

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 14: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 14 of 27777 Rustic Lane, Mountain View

Furniture and/or storage may of restricted access to some electrical components.•

Exterior light fixtures on motion or light sensors were not tested.•

Illustration 13A

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 15: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 15 of 27777 Rustic Lane, Mountain View

Heating System

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

The missing furnace air filter should be replaced. This will help keep dust from re-entering the occupied interior and

help keep the blower and duct work clean. (See Photo 10)

! 1.

The heating system is dirty and in this condition will operate inefficiently. We recommend a qualified HVAC

contractor be retained to service, clean, and tune the system.

2.

Some of the crawlspace heating ducts are in contact to the ground. This is conducive to corrosion and/or damage.

We recommend a minimum of six inches of clearance be provided.

3.

MAINTENANCE ITEMS & GENERAL INFORMATION

This home is heated with a mid efficiency forced air furnace. In this type of furnace, air is circulated by a blower

motor through a heat exchanger, which is heated by the burner unit at the base. An induced draft motor is used to

force the exhaust from the furnace to the exterior

4.

One or more ducts in the crawl space are dented and restricting the flow of air. We recommend all damaged ducts be

repaired or replaced as necessary.

5.

As per ASHI standards determining furnace heat supply adequacy or inadequacy, distribution balance or sizing of the

unit or units is not a part of this inspection.•

The wall mount and/or window mounted air conditioning unit (if applicable) was not inspected and are excluded from

this report.•

Heating and/or air conditioning registers where accessible were visually inspected. Manual operation of the registers

was not performed.•

As per ASHI standards the heat exchanger of the furnace was not inspected and interior portions of the heater were

restricted. For additional information we recommend the services of a licensed heating contractor. As a free public

service, the local utility company (PG&E) will perform a "safety" review of the heat exchanger and other gas operated

components. We recommend that you take advantage of this service before the next seasonal operation.

Inspection of the heater and/or air conditioner thermostat is limited to operating the units(s) on and off function only.

Testing of the thermostat timer, temperature accuracy, clock, set back functions, etc. were not performed.•

This is a visual inspection to the accessible areas only. The inspection of the heating system is general and not technically

exhaustive. A detailed evaluation of the furnace heat exchanger is beyond the scope of this inspection.

LIMITATIONS:

The heating system which was operated at the time of our inspection shows no visible evidence of major defects.

The typical life cycle for a heating unit such as this is 20-25 years. The heating system is older and may be approaching

the end of its life cycle. Some units will last longer; others can fail prematurely. Please be aware that shutting the gas off

to this unit for any reason could cause the heat exchanger to contract and crack.

ITEM DESCRIPTIONS:

Primary Energy Source • Gas

Heating System Type • Forced Air • Manufacturer: Trane • BTU's: 140,000 • Age (years): 22 • Location:

Laundry

Distribution • Ductwork

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 16: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 16 of 27777 Rustic Lane, Mountain View

Cooling/Heat Pump System

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

The data plate on the cooling system was not visible or legible at the time of this inspection.1.

The air conditioning condenser unit is not mounted or secured to the platform properly. We recommend it be secured

or mounted as necessary.

2.

This is a visual inspection to the accessible areas only. Air conditioning and heat pump systems, like most mechanical

components, can fail at any time.

LIMITATIONS:

The system shows no visible evidence of major defects.

The air conditioning system could not be tested as the outdoor temperature was below 65 degrees F. (See Illustration 6D)

ITEM DESCRIPTIONS:

Energy Source • Electricity

System Type • Air Cooled Central • Manufacturer: Trane and Fujit • Location: Right Side • Tons: 5 •

Age (years): 18

Illustration 6D

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 17: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 17 of 27777 Rustic Lane, Mountain View

Insulation/Ventilation

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

The crawl space ventilation screens are obstructed by vegetation, storage and/or insulation. All obstructions should be

cleared or opened to aid in crawl space cross ventilation.

1.

Insulation/ventilation type and levels in concealed areas cannot be determined. No destructive tests were performed.•

Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be

positively identified without a detailed inspection and laboratory analysis. This is beyond the scope of the inspection.•

An analysis of indoor air quality is beyond the scope of this inspection.•

Any estimates of insulation "R" values or depths are rough average values.•

This is a visual inspection to the accessible areas only.

LIMITATIONS:

Insulation levels are typical for a home of this age and construction.

ITEM DESCRIPTIONS:

Exterior Walls Insulation • Unknown

Attic/Roof Insulation • Fiberglass • Depth (inches): 4" - 6"

Attic/Roof Ventilation • Roof Vents • Soffit vents

Crawlspace Insulation • None

Crawl Space Ventilation • Exterior wall vent(s)

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 18: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 18 of 27777 Rustic Lane, Mountain View

Plumbing

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

The toilet in the hall bathroom and master bathroom are loose and should be properly re-secured, tightened and

caulked. (See Illustration 5B) (See Photo 11)

! 1.

The hall bathroom and master bathroom drains are leaking into the crawl space. We recommend all leaks be

repaired. (See Photo 20)

! 2.

The water heater vent pipe or hood is loose and exhaust leakage was evident. This is a potential safety concern that

should be addressed. We recommend the vent and hood be properly installed. (See Photo 18)

! 3.

There is evidence of heavy corrosion and rust, but no leakage on the exterior of the exposed and accessible metal

supply piping in the crawl space. This piping should be monitored for leakage and repaired as necessary. Upgrading

this piping and connections should also be considered.

4.

Water and gas shut-off valves, including but not limited to seismic, excess flow shut-off valves and gas fireplace

valves where applicable, were not operated or tested. Identification of these devices is limited to the accessible areas

only.

Portions of the plumbing system concealed by finishes and/or storage (below sinks, below the structure and beneath

the yard) were not inspected.•

Water pressure and water quality is not tested. The effect of lead content in solder and/or supply lines is beyond the

scope of the inspection.•

Inspection of any water conditioning system (filters, purifiers, softeners, etc.) is beyond the scope of this inspection

and are excluded from this report.•

Inspection of any lawn sprinkler system is beyond the scope of this inspection and are excluded from this report

(unless noted otherwise).•

The interior portions of the water heater were restricted. For additional information we recommend the services of a

licensed plumbing contractor. As a free public service, the local utility company (PG&E) will perform a "safety" review

of the interior of the water heater and other gas operated components. We recommend that you take advantage of

this service before the next seasonal operation.

HomeGuard Incorporated does not determine if any fixtures or toilets are water conserving.•

This is a visual inspection to the accessible areas only.

LIMITATIONS:

The water pressure supplied to the fixtures is reasonably good. A typical drop in flow was experienced when two fixtures

were operated simultaneously.

The plumbing system appears to be in good condition.

ITEM DESCRIPTIONS:

Main Water Valve Location • Location: Exterior Front

Supply Piping • Copper Pipe

Drain/Waste/Vent • Galvanized Steel • Cast Iron

Main Gas Valve Location • Exterior Side

Water Heaters • Manufacturer: A.O. Smith • Capacity: 50 Gallons • Approximate Age (years): 5 • Gas

• Location: Laundry

Seismic Gas Shut-off • Not Present

Excess Flow Gas Shut-off • Not Present

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 19: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 19 of 27777 Rustic Lane, Mountain View

Illustration 5B

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 20: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 20 of 27777 Rustic Lane, Mountain View

Interior

COMMENTS:

RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.

INTERIOR

The mirror on the front left bedroom closet door is cracked/damaged. We recommend replacement. (See Photo 13)! 1.

The openings in the railing are larger than 4". For improved safety it is recommended that the railing be altered for an

opening of less than 4". (See Illustration 7B) (See Photo 17)

! 2.

Cracked, deteriorated and/or missing floor tile grout and caulk in various areas should be replaced. Water leaking

through non-sealed areas can cause damage. Damage caused by water seepage cannot be determined by this visual

inspection.

3.

Holes were noted in one or more of the interior walls near the doors. This condition appears to be caused by the door

knobs. We recommend installation of door stops and the wall surface be repaired and refinished to restore its

appearance.

4.

There is evidence of Vermin activity in the structure. It is likely that this infestation is also in inaccessible areas. The

owner is advised to contact the appropriate tradesperson for any remedial measures necessary.

5.

BATHROOMS

Cracked shower wall tile in the hall bathroom should be replaced. Water leaking through non-sealed areas can cause

damage. Damage caused by water seepage cannot be determined by visual observation. (See Photo 12)

! 6.

The escutcheons at the master bathroom shower faucet, spout or shower head are loose. We recommend tightening

and/or sealing this trim piece for a better appearance and to avoid leakage in this area. (See Photo 15)

! 7.

The hall bathroom and master bathroom sink basin shows evidence of heavy wear, chipping and/or cosmetic

cracking. This is primarily a cosmetic condition, however it may be desirable to refinish or replace it for cosmetic

considerations and/or prolong the life of the sink.

8.

Cracked, deteriorated and/or missing grout and caulk in the hall bathroom and master bathroom shower should be

replaced. Water leaking through non-sealed areas can cause damage. Damage caused by water seepage cannot be

determined by this visual observation. A flexible caulking material is recommended rather than rigid cementious grout.

9.

OTHER/MISC.

California law requires that all homes have a State Fire Marshall approved Carbon Monoxide Detector installed

outside of the sleeping quarters and on each level of the home. At the time of this inspection a Carbon Monoxide

Detector was located. As a carbon monoxide detector was not noted in all of the recommended locations additional

detectors should be installed.

! 10.

Generally speaking, the kitchen is in good condition.

Generally speaking, the bathroom(s) are in good condition.

The interior finishes of the home are considered to be in good condition.

All appliances that were tested appear to be in good condition and responded satisfactorily.

The windows and doors are of good quality.

ITEM DESCRIPTIONS:

Kitchen Appliances Tested • Built in Electric Oven • Electric Cooktop • Microwave • Dishwasher • Waste Disposer •

Exhaust Hood

Laundry Facilities/Hookup • 240 Volt Circuit for Dryer • 120 Volt Circuit for Washer • Gas Piping for Dryer • Hot

and Cold Water Supply for Washer • Waste Standpipe for Washer • Dryer vent noted

Wall Finishes • Drywall/Plaster

Ceiling Finishes • Drywall/Plaster

Floor • Tile/Stone • Vinyl

Doors • Hollow Core • Raised Panel • French • Sliding

Window style and Glazing • Casement • Sliders • Fixed Pane • Double Pane

Fireplace/Wood Stove • Zero Clearance • Gas

Other Componets Inspected • Smoke Detector • Door Bell

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 21: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 21 of 27777 Rustic Lane, Mountain View

ENVIROMENTAL ISSUES:

Issues Based on the age of this home, there is a possibility the structure may contain asbestos such as ceiling

texture, insulation on the distribution piping and/or transit piping and siding. This can only be verified by laboratory

analysis. The Environmental Protection Agency (E.P.A.) reports that asbestos represents a health hazard if “friable”

damaged, crumbling, or in any state that allows the release of fibers. If replacement necessitates the removal of the

acoustic ceiling or insulation, a specialist should be engaged. If any sections of this insulation are indeed friable, or

become friable over time, a specialist should be engaged. Further guidance is available from the Environmental

Protection Agency (E.P.A.). Due to the age of construction, it is likely that there are other materials within the home

that contain asbestos but are not identified by this inspection report.

11.

Carbon monoxide is a colorless, odorless gas that can result from a faulty fuel burning furnace, range, water heater,

space heater or wood stove. Proper maintenance of these appliances is the best way to reduce the risk of carbon

monoxide poisoning. For more information, consult the Consumer Product Safety Commission CPSC at

www.cpsc.gov for further guidance.

12.

MAINTENANCE ITEMS & GENERAL INFORMATION

INTERIOR

The evaluation of the thermal pane windows ("dual pane/glazed") is limited to accessible windows exhibiting

noticeable conditions at the time of our inspection, such as condensation and/or evidence of moisture developing

between the panes of glass. Due to the known design and/or characteristics associated with thermal pane windows,

conditions may be discovered at a later date, however seal failure can occur at any time.

13.

KITCHEN

Testing of the oven cleaning function is beyond the scope of this inspection. For proper operation and testing of this

function we recommend consultation with the existing homeowner.

14.

The adequacy of the fireplace draw cannot be determined during a visual inspection.•

The operation of the dishwasher was limited to a filling and draining cycle only, however due to time limitations timers,

dryer cycles and/or higher functions were not tested. For additional information in regards to the operation and full

function of the dishwasher we recommend consultation with the owner or appropriate trades.

The fireplace was visually inspected however the gas burner was not tested.•

Furniture, storage, appliances and/or wall hangings restricted the inspection of the interior.•

No access was gained to the wall cavities of the home.•

Kitchen appliances were operated unless noted otherwise. However they were not inspected for installation according

to manufacturer specifications and were not evaluated for performance, efficiency or adequacy during their operation.

No refrigerators whether "built in" or portable are operated, inspected or tested.

All appliances not "built in" to the structure such as washing machine, dryer, refrigerator and/or countertop microwaves

were not inspected and are excluded from this report. No refrigerators whether "built in" or portable are operated,

inspected or tested.

Fireplace screens or doors were not inspected and are excluded from this report•

This is a visual inspection to the accessible areas only. Assessing the quality of interior finishes is highly subjective.

Issues such as cleanliness, cosmetic flaws, quality of materials, architectural appeal and color are outside the scope of

this inspection. Comments are general, except where functional concerns exist. Due to texturing and painting of interior

surfaces there is no possible way of determining point of origin of any gypsum (sheetrock) material without destructive

testing. HomeGuard Incorporated does not perform any destructive testing. Smoke detectors and carbon monoxide

detectors were not manually tested. The sensors of these units are not tested. Both smoke detectors and carbon

monoxide detectors have a limited life span and should be replaced according to the manufactures instructions.

LIMITATIONS:

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 22: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 22 of 27777 Rustic Lane, Mountain View

Illustration 7B

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 23: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 23 of 27777 Rustic Lane, Mountain View

Photographs

No relative importance should be placed on the photographs provided in this report. The photographs in this

report do not necessarily illustrate all of the damage in any particular finding. Also, not all problem areas will

be supported with photographs. Please contact HomeGuard if you have any questions.

Photo 1 Photo 2

Photo 3 Photo 4

Photo 5 Photo 6

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 24: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 24 of 27777 Rustic Lane, Mountain View

Photo 7 Photo 9

Photo 10 Photo 11

Photo 12 Photo 13

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 25: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 25 of 27777 Rustic Lane, Mountain View

Photo 14 Photo 15

Photo 17 Photo 18

Photo 19 Photo 20

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 26: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 26 of 27777 Rustic Lane, Mountain View

Maintenance Advice

UPON TAKING OWNERSHIP

After taking ownership of a new home, there are some maintenance and safety issues that should be addressed

immediately. The following checklist should help you undertake these improvements.

Change the locks on all exterior entrances, for improved security.

Check that all windows and doors are secure. Improve window hardware as necessary. Security rods can be added

to sliding windows and doors. Considerations could also be given to a security system.

Install smoke detectors on each level of the home. Ensure that there is a smoke detector outside all sleeping areas.

Replace batteries on any existing smoke detectors and test them. Make a note to replace batteries again in one year.

Create a plan of action in the event of a fire in your home. Ensure that there is an operable window or door in

every room of the house. Consult with your local fire department regarding fire safety issues and what to do in

the event of a fire.

Examine driveways and walkways for trip hazards. Undertake repairs where necessary.

Examine the interior of the home for trip hazards. Loose or torn carpeting and flooring should be repaired.

Undertake improvements to all stairways, decks, porches and landings where there is a risk of falling or stumbling.

Review your home inspection report for any items that require immediate improvement or further investigation.

Address these areas as required.

Install rain caps and vermin screens on all chimney flues, as necessary.

Investigate the location of the main shut-offs for the plumbing, heating and electrical systems. If you attend the home

inspection, these items have been pointed out to you.

REGULAR MAINTENANCE

EVERY MONTH

Check that fire extinguisher(s) are fully charged. Re-charge if necessary.

Examine heating/cooling air filters and replace or clean as necessary.

Inspect and clean humidifiers and electronic air cleaners.

If the house has hot water heating, bleed radiator valves.

Clean gutters and downspouts. Ensure that downspouts are secure, and that the discharge of the downspouts is

appropriate. Remove debris from window wells.

Carefully inspect the condition of shower enclosures. Repair or replace deteriorated grout and caulk. Ensure that

water is not escaping the enclosure during showering. Check below all plumbing fixtures for evidence of leakage.

Repair or replace leaking faucets or shower heads.

Secure loose toilets, or repair flush mechanisms that become troublesome.

SPRING AND FALL

Examine the roof for evidence of damage to roof covering, flashings and chimneys.

Look in the attic (if accessible) to ensure that roof vents are not obstructed. Check for evidence of leakage,

condensation or vermin activity. Level out insulation if needed.

Trim back tree branches and shrubs to ensure that they are not in contact with the house.

Inspect the exterior walls and foundation for evidence of damage, cracking or movement. Watch for bird nests or other

vermin or insect activity.

Survey the basement and/or crawl space walls for evidence of moisture seepage.

Look at overhead wires coming to the house. They should be secure and clear of trees or other obstructions.

Ensure that the grade of the land around the house encourages water to flow away from the foundation.

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 27: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

Page 27 of 27777 Rustic Lane, Mountain View

Inspect all driveways, walkways, decks, porches, and landscape components for evidence of deterioration, movement

or safety hazards.

Clean windows and test their operation. Improve caulking and weather-stripping as necessary. Watch for evidence

of rot in wood windows frames. Paint and repair window sills and frames as necessary.

Test all ground fault circuit interrupter (GFCI) devices, as identified in the inspection report.

Shut off isolating valves for exterior hose bibs in the fall, if below freezing temperatures are anticipated.

Test the Temperature and Pressure Relief (TPR) Valve on water heaters.

Inspect for evidence of wood boring insect activity. Eliminate any wood/soil contact around the perimeter of the home.

Test the overhead garage door opener, to ensure that the auto-reverse mechanism is responding properly. Clean and

lubricate hinges, rollers and tracks on overhead doors.

Replace or clean exhaust hood filters.

Clean, inspect and/or service all appliances as per the manufacturer's recommendations.

ANNUALLY

Replace smoke detector batteries.

Have the heating, cooling and water heater systems cleaned and serviced.

Have chimneys inspected and cleaned. Ensure that rain caps and vermin screens are secure.

Examine the electrical panels, wiring and electrical components for evidence of overheating. Ensure that all

components are secure. Flip the breakers on and off to ensure that they are not sticky.

If the house utilizes a well, check and service the pump and holding tank. Have the water quality tested. If the

property has a septic system, have the tank inspected (and pumped as needed).

If your home is in an area prone to wood destroying insects (termites, carpenter ants, etc.), have the home

inspected by a licensed specialist. Preventive treatments may be recommended in some cases.

PREVENTION IS THE BEST APPROACH

Although we've heard it many times, nothing could be more true than the old cliche "an ounce of prevention is worth a

pound of cure." Preventative maintenance is the best way to keep your house in great shape. It also reduces the risk of

unexpected repairs and improves the odds of selling your house at fair market value, when the time comes.Please feel free to contact our office should you have any questions regarding the operation or maintenance of your

home. Enjoy your home!

q

q

q

q

q

q

q

q

q

q

q

q

q

q

q

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958

Page 28: HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work clean. (See Photo 10) 11. Photo 10 Plumbing The hall bathroom and master bathroom drains

$555.00

Invoice No: LIV553925P

Report No: 438958 TPR

Invoice Date: 2/14/2018

Inspection: 2/13/2018

Address: 777 Rustic Lane

Mountain View CA, 94040

Escrow#:

Debbie Blackwell

777 Rustic Lane

Mountain View, CA 94040

Invoice

Property Information:

Bill To:

Billing Information:

DUE UPON RECEIPT

Complete

Total Due: $555.00

HomeGuardIncorporated

Please remit to 510 Madera Ave., San Jose, CA 95112

There is a $25 fee for all returned checks

HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958