HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work...
Transcript of HomeGuard Incorporated...entering the occupied interior and help keep the blower and duct work...
777 Rustic Lane, Mountain View
February 13, 2018
Home Inspection Report
Debbie Blackwell
777 Rustic Lane
Inspected by:Ordered by:
Paul Salinas
HomeGuardIncorporated
Mountain View, CA 94040
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Table of Contents
Report Overview 3
Structure 9
Roofing 10
Exterior 11
Electrical 13
Heating System 15
Cooling/Heat Pump System 16
Insulation/Ventilation 17
Plumbing 18
Interior 20
Photographs 23
Maintenance Advice 26
Page 2 of 27777 Rustic Lane, Mountain View
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 3 of 27777 Rustic Lane, Mountain View
Report Overview
A GENERAL DESCRIPTION OF THE STRUCTURE
This is an average quality one story single family residence. Approximately 43 years old. Ongoing maintenance is
required and improvements to the systems of the home will be needed over time. The improvements that are
recommended in this report are not considered unusual for a home of this age and location. Please remember that there is
no such thing as a perfect home.
! - IMMEDIATE RECOMMENDED IMPROVEMENTS
The following is a synopsis of the potentially significant improvements that should be budgeted for over the short term.
Other significant improvements, outside the scope of this inspection, may also be necessary. Please refer to the body of
this report for further details on these and other recommendations. No relative importance should be placed on the
photographs provided in this report. The photographs in this report do not necessarily illustrate all of the damage in any
particular finding. Also, not all problem areas will be supported by photographs. If more than one photograph is available
for a particular item, additional photographs can be found at the end of the report in the section entitled 'Photographs'.
Please contact HomeGuard if you have any questions.
WEATHER CONDITIONS
Dry weather conditions prevailed at the time of the inspection.
Roofing
Leaks were noted in the downspouts and/or gutters at the rear. During wet
weather conditions these areas are more obvious and during dry weather
conditions they are noted from the stains at the areas where the leaks have
occurred. We recommend all leaks be repaired. (See Illustration 4B) (See Photo
5)
1.
Photo 5
Exterior
Personal storage was blocking access to the interior of the garage. Therefore,
the area is considered inaccessible and was not fully inspected. With access
and an opportunity for complete inspection, conditions in need of attention may
be discovered. Ideally, the personal belongings should be removed so the area
may be inspected. (See Photo 9)
2.
Photo 9
The cracked and heaved sections of driveway present a trip hazard. This
condition should be corrected for improved safety. (See Photo 1)
3.
Photo 1
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 4 of 27777 Rustic Lane, Mountain View
Exterior
Water damage was observed to the roof eaves/sheathing at the front. We
recommend the services of a licensed general contractor and/or structural pest
control company. (See Photo 2)
4.
Photo 2
Water damage Q observed to the rafters at the rear. We recommend the
services of a licensed general contractor and/or structural pest control company.
(See Photo 6)
5.
Photo 6
Water damage was observed to the fascia at the front. We recommend the
services of a licensed general contractor and/or structural pest control company.
(See Photo 3)
6.
Photo 3
Electrical
Exterior receptacles at the rear are missing a water proof cover plate. We
recommend a exterior approved cover be installed. (See Photo 7)
7.
Photo 7
The damaged/cracked outlet cover plates should be replaced. (See Photo 14)8.
Photo 14
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 5 of 27777 Rustic Lane, Mountain View
Electrical
There is a long section of conduit installed at various areas that is not
adequately supported and loose. We recommend that all conduit be supported
and secured in accordance with conventional building standards. (See Photo 19)
9.
Photo 19
An exterior outlet at the left side of the wall is faulty or damaged. We
recommend it be replaced. (See Photo 4)
10.
Photo 4
Heating System
The missing furnace air filter should be replaced. This will help keep dust from re-
entering the occupied interior and help keep the blower and duct work clean.
(See Photo 10)
11.
Photo 10
Plumbing
The hall bathroom and master bathroom drains are leaking into the crawl
space. We recommend all leaks be repaired. (See Photo 20)
12.
Photo 20
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 6 of 27777 Rustic Lane, Mountain View
Plumbing
The water heater vent pipe or hood is loose and exhaust leakage was evident.
This is a potential safety concern that should be addressed. We recommend the
vent and hood be properly installed. (See Photo 18)
13.
Photo 18
The toilet in the hall bathroom and master bathroom are loose and should be
properly re-secured, tightened and caulked. (See Illustration 5B) (See Photo 11)
14.
Photo 11
Interior
The mirror on the front left bedroom closet door is cracked/damaged. We
recommend replacement. (See Photo 13)
15.
Photo 13
The openings in the railing are larger than 4". For improved safety it is
recommended that the railing be altered for an opening of less than 4". (See
Illustration 7B) (See Photo 17)
16.
Photo 17
Cracked shower wall tile in the hall bathroom should be replaced. Water leaking
through non-sealed areas can cause damage. Damage caused by water
seepage cannot be determined by visual observation. (See Photo 12)
17.
Photo 12
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 7 of 27777 Rustic Lane, Mountain View
Interior
The escutcheons at the master bathroom shower faucet, spout or shower head
are loose. We recommend tightening and/or sealing this trim piece for a better
appearance and to avoid leakage in this area. (See Photo 15)
18.
Photo 15
California law requires that all homes have a State Fire Marshall approved
Carbon Monoxide Detector installed outside of the sleeping quarters and on each
level of the home. At the time of this inspection a Carbon Monoxide Detector
was located. As a carbon monoxide detector was not noted in all of the
recommended locations additional detectors should be installed.
19.
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 8 of 27777 Rustic Lane, Mountain View
The Scope of the InspectionAll components designated for inspection in the ASHI standards of practice are inspected, except as may be noted in the
"Limitations" section within the report. This inspection will not disclose compliance with regulatory requirements (codes,
regulation laws, ordinances, etc.)
This inspection is visual only. Only a representative sample of the building and system components was viewed. No
destructive testing or dismantling of building components was performed. The strength, adequacy, effectiveness, or
efficiency of any system or components was not determined. Not all recommended improvements will be identified in this
inspection. Unexpected repairs should still be anticipated. This inspection should not be considered a guarantee or
warranty of any kind. The purpose of our inspection is to provide a general overview of the structure reflecting the
conditions present at the time of this inspection. The inspection is performed by visual means only, reflecting only the
opinions of the inspector. Nothing in the report, and no opinion of the inspector, should be construed as advice to
purchase, or to not purchase, the property. It is the goal of this inspection to put the buyer in a better position to make a
buying decision
Our inspection does not address, and is not intended to address, the possible presence of hazardous plants or animals or
danger from known and unknown environmental pollutants such as, but not limited to, asbestos, mold, radon gas, lead,
urea formaldehyde, underground storage tanks, soil contamination and other indoor and outdoor substances, water
contamination, toxic or flammable chemicals, water or airborne related illness or disease, and all other similar or
potentially harmful substances and conditions. This property was not inspected for the presence or absence of health
related molds or fungi. We are neither qualified, authorized nor licensed to inspect for health related molds or fungi. If you
desire information about the presence or absence health related molds, you should contact the appropriate specialist. Be
aware that many materials used in building construction may potentially contain hazardous substances. Furthermore,
other environmental concerns may exist elsewhere. An environmental specialist should be contacted if additional
information is desired about these issues.
PLEASE NOTE: Important disclosure information and other inspection reports may exist. All present and prior
disclosures along with other inspection reports should be reviewed and any adverse conditions and/or concerns that may
not be mentioned in our report should be addressed prior to the close of escrow. Furthermore, there may be conditions
known by the seller that have not been disclosed to us.
Pictures are provided to assist in clarifying some of the findings made in the report. No relative importance should be
placed on these pictures. There are likely to be significant comments that do not have pictures associated with them.
Please read the report thoroughly.
Sections of this building appear to have been remodeled. We recommend consultation with the owner or local municipality
to determine whether the necessary permits were obtained, inspections performed and final signatures received.
BINDING ARBITRATION PROVISION
Any controversy or claim arising out of or relating to the inspection performed by HomeGuard Incorporated shall be settled by
final and binding arbitration filed by the aggrieved party with and administered by the American Arbitration Association (hereafter
referred to as "AAA") in accordance with its Construction Arbitration Rules in effect at the time the claim is filed. The Rules,
information and forms of the AAA may be obtained and all claims shall be filed at any office of the AAA or at Corporate
Headquarters, 335 Madison Avenue, Floor 10, New York, New York 10017-4605. Telephone: 212-716-5800, Fax: 212-716-5905,
Website: http://www.adr.org/. The arbitration of all disputes shall be decided by a neutral arbitrator, and judgment on the award
rendered by the arbitrator may be entered in any court having competent jurisdiction thereof. Any such arbitration will be
conducted in the city nearest to the property that was inspected by HomeGuard Incorporated having an AAA regional office.
Each party shall bear its own costs and expenses and an equal share of the administrative and arbitrators’ fees of arbitration.
This arbitration Agreement is made pursuant to a transaction involving interstate commerce, and shall be governed by the
Federal Arbitration Act, 9 U.S.C. Sections 1-16. THE PARTIES UNDERSTAND THAT THEY WOULD HAVE HAD A RIGHT OR
OPPORTUNITY TO LITIGATE THROUGH A COURT AND TO HAVE A JUDGE OR JURY DECIDE THEIR CASE, BUT THEY
CHOOSE TO HAVE ANY AND ALL DISPUTES DECIDED THROUGH ARBITRATION. BY SIGNING THIS AGREEMENT, THE
PARTIES ARE GIVING UP ANY RIGHT THEY MIGHT HAVE TO SUE EACH OTHER.
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 9 of 27777 Rustic Lane, Mountain View
Structure
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
There is a condition known as efflorescence on portions of the foundation walls. This fuzzy material is a salt deposit
left when moisture in the foundation evaporates on the inside of the foundation. This indicates an occasional surplus
of moisture on the outside of the foundation. Steps could be taken to improve the exterior drainage (See “Roofing”
section downspout locations for additional comments/recommendations in regard to this condition).
1.
Minor cracks were observed in the foundation walls of the house. This type of cracking usually occurs during the
curing process of the foundation as is typical of most houses. If further information is desired in regards to these
cracks, the appropriate trades should be engaged.
2.
Past repairs have been performed in the crawl space. We recommend consultation with the owners regarding the
extent of the repairs and any permits that may have been obtained and/or signed off.
3.
The soil in this area is considered "expansive" because it expands and contracts with the variations of the moisture
content. This may, in turn, cause movement in the support structure. This movement may cause cosmetic cracking,
sticking doors, etc. Maintaining moisture content is very important along with good site drainage, effective
landscaping and landscape watering is equally important. This will keep the soil form expanding or shrinking
excessively. If desired, information regarding expansive soils could be obtained from a soils engineer.
4.
Structural components concealed behind finished surfaces could not be inspected.•
Only a representative sampling of visible structural components was inspected.•
Furniture and/or storage restricted access to some of the structural components.•
This is a visual inspection to the accessible areas only. Assessing the structural integrity of a building is beyond the scope
of a typical inspection. A certified professional engineer is recommended where there are structural concerns about the
building.
LIMITATIONS:
The sill appeared to be adequately secured (anchor bolts or straps) to the foundation, unless noted otherwise.
Evidence of past repairs and/or modifications have been made to the foundation. The owner may have information about
the repairs or remodeling work, and any permits that were required, obtained and completed.
ITEM DESCRIPTIONS:
Wall/Foundation Structure • Wood Frame
Attic Access Location • Hallway • Attic Method Of Inspection: From the Access
Ceiling Structure • Truss
Roof Structure • Truss
Roof Sheathing • Not Visible
Crawl Space Access • Closet
Foundation • Poured Concrete
Floor Structure • Wood Joist • Wood Columns • Wood Floor Beams • Plywood or Orientated Strand
Board
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 10 of 27777 Rustic Lane, Mountain View
Roofing
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
Leaks were noted in the downspouts and/or gutters at the rear. During wet weather conditions these areas are more
obvious and during dry weather conditions they are noted from the stains at the areas where the leaks have occurred.
We recommend all leaks be repaired. (See Illustration 4B) (See Photo 5)
! 1.
The chimney does not have a spark arrestor or rain cap. A rain cap and/or screen should be installed on the chimney.
(See Illustration 3I)
2.
Debris was noted inside the gutters at various areas. We recommend the downspouts and gutters be cleaned out.3.
The downspouts discharge water adjacent to the structure. Water should be directed to flow at least 5' feet away from
the building at the point of discharge. The installation of underground drainage where applicable will help control
surface drainage.
4.
This is a visual inspection to the accessible areas only. Roofing life expectancies can vary depending on several factors.
Any estimates on remaining life are approximations only. This assessment of the roof does not preclude the possibility of
leakage. Leakage can develop at any time and may depend on rain intensity, wind direction, ice build up, etc.
LIMITATIONS:
We recommend reviewing a roof inspection report performed by a licensed roof inspector on this structure.
ITEM DESCRIPTIONS:
Roof • Composition shingle • Method of inspection: From The Roof.
Chimney • Masonry • Method of inspection: From The Roof.
Gutters and Downspouts • Metal • Installation Of Gutters/Downspouts: Full • Downspouts Discharge Location:
Above Grade
Illustration 3I Illustration 4B
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 11 of 27777 Rustic Lane, Mountain View
Exterior
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
The cracked and heaved sections of driveway present a trip hazard. This condition should be corrected for improved
safety. (See Photo 1)
! 1.
Water damage was observed to the roof eaves/sheathing at the front. We recommend the services of a licensed
general contractor and/or structural pest control company. (See Photo 2)
! 2.
Water damage Q observed to the rafters at the rear. We recommend the services of a licensed general contractor
and/or structural pest control company. (See Photo 6)
! 3.
Water damage was observed to the fascia at the front. We recommend the services of a licensed general contractor
and/or structural pest control company. (See Photo 3)
! 4.
The proximity of the tree at various areas of the wall could disrupt drainage pipes, cause mechanical damage to the
exterior of the house or influence the foundation over time. For additional information and recommendations we
recommend appropriate trades be consulted. (See Illustration 8E)
5.
There are minor sized cracks in the exterior stucco that should be patched and sealed as part of preparation for the
next painting. Flexible patching materials are recommended rather than rigid patching compounds.
6.
Obvious repairs and/or modifications have been made to various areas of the exterior walls. The owner may have
information about the original conditions, the repairs or remodeling work and any permits that were required.
7.
The window(s) in the exterior door lack tempered glass (special safety glass that will not shatter). For safety reasons,
we recommend the installation of tempered glass.
8.
MAINTENANCE ITEMS & GENERAL INFORMATION
Due to possible damage occurring to the garage door during testing, the auto reverse mechanism on the overhead
garage door was not tested. We recommend the auto reverse be tested by appropriate trades. Refer to the owner’s
manual or contact the manufacturer for more information. There is a serious risk of injury, particularly to children,
under this condition. Information on garage door openers is available from the Consumer Product Safety
Commission at www.cpsc.gov.
9.
This home was constructed without the use of a weep screed at the base of the stucco. Although this was an
accepted construction method it can allow condensation to build up and not drain properly. For further information we
recommend appropriate trades be consulted
10.
This is a visual inspection to the accessible areas only.
LIMITATIONS:
The exterior of the home shows signs of normal wear and tear for a home of this age and construction.
Personal storage was blocking access to the interior of the garage. Therefore, the area is considered inaccessible and
was not fully inspected. With access and an opportunity for complete inspection, conditions in need of attention may be
discovered. Ideally, the personal belongings should be removed so the area may be inspected. (See Photo 9)
ITEM DESCRIPTIONS:
Lot Topography • Level grade
Driveway • Concrete
Walkway & Sidewalks • Concrete
Retaining Walls/Abutments • None
Fencing/Gates • Wood • Brick
Steps, Porch/Deck • Brick/Pavers • Concrete • Unknown
Fascia, Eaves and Rafters • Wood • Open Rafters
Exterior Walls • Wood Siding • Brick Veneer • Stucco
Windows • Vinyl
Doors • Wood • Sliding Glass
The Swimming Pool Safety
Act
• Not Applicable
Main Garage • Attached
Main Garage Door/Opener • Wood • Automatic Opener Installed
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 12 of 27777 Rustic Lane, Mountain View
A representative sample of exterior components was inspected.•
The inspection does not include an assessment of geological conditions, site stability and property surface drainage
runoff.•
The detached outbuilding, related equipment and ancillary wiring and plumbing services were not inspected and are
excluded from this report.•
Interior finishes (floors, walls, ceilings) and/or insulation restricted the inspection of the garage.•
Illustration 8E
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 13 of 27777 Rustic Lane, Mountain View
Electrical
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
The damaged/cracked outlet cover plates should be replaced. (See Photo 14)! 1.
Exterior receptacles at the rear are missing a water proof cover plate. We recommend a exterior approved cover be
installed. (See Photo 7)
! 2.
There is a long section of conduit installed at various areas that is not adequately supported and loose. We
recommend that all conduit be supported and secured in accordance with conventional building standards. (See
Photo 19)
! 3.
An exterior outlet at the left side of the wall is faulty or damaged. We recommend it be replaced. (See Photo 4)! 4.
DISCRETIONARY IMPROVEMENTS AND/OR UPGRADES
The installation of ground fault circuit interrupter "GFCI" devices is advisable on exterior, garage, bathroom and some
kitchen outlets. Any whirlpool or swimming pool equipment should also be fitted with "GFCI"s. A ground fault circuit
interrupter "GFCI" offers protection from shock or electrocution. Please note that "GFCI" may already be in one or
more of these areas. See "description" section above for exact location of any "GFCI" which may be present on this
property. (See Illustration 13A)
5.
Today's electrical standard now requires a device called an arc-fault circuit interrupter "AFCI". As defined in proposals
for the 1999 NEC, an "AFCI" is a device that provides protection from effects of arc faults by recognizing
characteristics unique to arcing, and then de-energizing the circuit upon detection of an arc fault. Its basic application
is protection of 15 amp and 20 amp branch circuits in single and multi-family residential occupancies. These devices
are now installed in the habitable bedrooms of new construction.
6.
Due to inaccessibility of concealed wiring or undocumented improvements of the structure, we are unable to predict
whether the number of circuits within a home will be sufficient for the needs of the occupants during a typical home
inspection. If fuses blow or breakers trip regularly, this may indicate that additional loads or remodeling modifications
may have been added to existing circuits.
•
Electrical components concealed behind finished surfaces could not be inspected.•
According to "ASHI" standards only a representative sampling of outlets and light fixtures were tested.•
This is a visual inspection to the accessible areas only. The inspection does not include (if applicable) low voltage
systems, telephone wiring, intercoms, alarm systems, TV cable, timers, central vacuum systems, exterior sprinkler
systems, exterior landscape lighting or exterior motion sensor lights. Also smoke detectors out of reach were only visually
inspected unless noted otherwise. We recommend these systems be checked by interested parties for proper operation
when possible.
LIMITATIONS:
The size of the electrical service is sufficient for typical single family needs.
The distribution of electricity within the home is good.
The 3-prong outlets that were tested were appropriately grounded.
Dedicated 240 volt circuits have been provided for all 240 volt appliances within the home.
Inspection of the electrical system revealed the need for minor improvements. A licensed electrician should be consulted
to undertake the improvements recommended below.
ITEM DESCRIPTIONS:
Service • 120/240 volt main service
Service Entrance • Underground Service Wires
Service Ground • Copper Ground Wire
Main disconnect • Breakers • Main Service Rating (Amps): 125
Main Distribution Panel • Breakers • Exterior Side • Panel Rating (Amps): 125
Branch/Auxillary Panel • Breakers • Hallway • Panel Rating (Amps): 125
Distribution Wiring • Copper Wire
Outlets • Grounded
Ground Fault Circuit
Interrupters
• None
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 14 of 27777 Rustic Lane, Mountain View
Furniture and/or storage may of restricted access to some electrical components.•
Exterior light fixtures on motion or light sensors were not tested.•
Illustration 13A
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 15 of 27777 Rustic Lane, Mountain View
Heating System
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
The missing furnace air filter should be replaced. This will help keep dust from re-entering the occupied interior and
help keep the blower and duct work clean. (See Photo 10)
! 1.
The heating system is dirty and in this condition will operate inefficiently. We recommend a qualified HVAC
contractor be retained to service, clean, and tune the system.
2.
Some of the crawlspace heating ducts are in contact to the ground. This is conducive to corrosion and/or damage.
We recommend a minimum of six inches of clearance be provided.
3.
MAINTENANCE ITEMS & GENERAL INFORMATION
This home is heated with a mid efficiency forced air furnace. In this type of furnace, air is circulated by a blower
motor through a heat exchanger, which is heated by the burner unit at the base. An induced draft motor is used to
force the exhaust from the furnace to the exterior
4.
One or more ducts in the crawl space are dented and restricting the flow of air. We recommend all damaged ducts be
repaired or replaced as necessary.
5.
As per ASHI standards determining furnace heat supply adequacy or inadequacy, distribution balance or sizing of the
unit or units is not a part of this inspection.•
The wall mount and/or window mounted air conditioning unit (if applicable) was not inspected and are excluded from
this report.•
Heating and/or air conditioning registers where accessible were visually inspected. Manual operation of the registers
was not performed.•
As per ASHI standards the heat exchanger of the furnace was not inspected and interior portions of the heater were
restricted. For additional information we recommend the services of a licensed heating contractor. As a free public
service, the local utility company (PG&E) will perform a "safety" review of the heat exchanger and other gas operated
components. We recommend that you take advantage of this service before the next seasonal operation.
•
Inspection of the heater and/or air conditioner thermostat is limited to operating the units(s) on and off function only.
Testing of the thermostat timer, temperature accuracy, clock, set back functions, etc. were not performed.•
This is a visual inspection to the accessible areas only. The inspection of the heating system is general and not technically
exhaustive. A detailed evaluation of the furnace heat exchanger is beyond the scope of this inspection.
LIMITATIONS:
The heating system which was operated at the time of our inspection shows no visible evidence of major defects.
The typical life cycle for a heating unit such as this is 20-25 years. The heating system is older and may be approaching
the end of its life cycle. Some units will last longer; others can fail prematurely. Please be aware that shutting the gas off
to this unit for any reason could cause the heat exchanger to contract and crack.
ITEM DESCRIPTIONS:
Primary Energy Source • Gas
Heating System Type • Forced Air • Manufacturer: Trane • BTU's: 140,000 • Age (years): 22 • Location:
Laundry
Distribution • Ductwork
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 16 of 27777 Rustic Lane, Mountain View
Cooling/Heat Pump System
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
The data plate on the cooling system was not visible or legible at the time of this inspection.1.
The air conditioning condenser unit is not mounted or secured to the platform properly. We recommend it be secured
or mounted as necessary.
2.
This is a visual inspection to the accessible areas only. Air conditioning and heat pump systems, like most mechanical
components, can fail at any time.
LIMITATIONS:
The system shows no visible evidence of major defects.
The air conditioning system could not be tested as the outdoor temperature was below 65 degrees F. (See Illustration 6D)
ITEM DESCRIPTIONS:
Energy Source • Electricity
System Type • Air Cooled Central • Manufacturer: Trane and Fujit • Location: Right Side • Tons: 5 •
Age (years): 18
Illustration 6D
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 17 of 27777 Rustic Lane, Mountain View
Insulation/Ventilation
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
The crawl space ventilation screens are obstructed by vegetation, storage and/or insulation. All obstructions should be
cleared or opened to aid in crawl space cross ventilation.
1.
Insulation/ventilation type and levels in concealed areas cannot be determined. No destructive tests were performed.•
Potentially hazardous materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be
positively identified without a detailed inspection and laboratory analysis. This is beyond the scope of the inspection.•
An analysis of indoor air quality is beyond the scope of this inspection.•
Any estimates of insulation "R" values or depths are rough average values.•
This is a visual inspection to the accessible areas only.
LIMITATIONS:
Insulation levels are typical for a home of this age and construction.
ITEM DESCRIPTIONS:
Exterior Walls Insulation • Unknown
Attic/Roof Insulation • Fiberglass • Depth (inches): 4" - 6"
Attic/Roof Ventilation • Roof Vents • Soffit vents
Crawlspace Insulation • None
Crawl Space Ventilation • Exterior wall vent(s)
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 18 of 27777 Rustic Lane, Mountain View
Plumbing
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
The toilet in the hall bathroom and master bathroom are loose and should be properly re-secured, tightened and
caulked. (See Illustration 5B) (See Photo 11)
! 1.
The hall bathroom and master bathroom drains are leaking into the crawl space. We recommend all leaks be
repaired. (See Photo 20)
! 2.
The water heater vent pipe or hood is loose and exhaust leakage was evident. This is a potential safety concern that
should be addressed. We recommend the vent and hood be properly installed. (See Photo 18)
! 3.
There is evidence of heavy corrosion and rust, but no leakage on the exterior of the exposed and accessible metal
supply piping in the crawl space. This piping should be monitored for leakage and repaired as necessary. Upgrading
this piping and connections should also be considered.
4.
Water and gas shut-off valves, including but not limited to seismic, excess flow shut-off valves and gas fireplace
valves where applicable, were not operated or tested. Identification of these devices is limited to the accessible areas
only.
•
Portions of the plumbing system concealed by finishes and/or storage (below sinks, below the structure and beneath
the yard) were not inspected.•
Water pressure and water quality is not tested. The effect of lead content in solder and/or supply lines is beyond the
scope of the inspection.•
Inspection of any water conditioning system (filters, purifiers, softeners, etc.) is beyond the scope of this inspection
and are excluded from this report.•
Inspection of any lawn sprinkler system is beyond the scope of this inspection and are excluded from this report
(unless noted otherwise).•
The interior portions of the water heater were restricted. For additional information we recommend the services of a
licensed plumbing contractor. As a free public service, the local utility company (PG&E) will perform a "safety" review
of the interior of the water heater and other gas operated components. We recommend that you take advantage of
this service before the next seasonal operation.
•
HomeGuard Incorporated does not determine if any fixtures or toilets are water conserving.•
This is a visual inspection to the accessible areas only.
LIMITATIONS:
The water pressure supplied to the fixtures is reasonably good. A typical drop in flow was experienced when two fixtures
were operated simultaneously.
The plumbing system appears to be in good condition.
ITEM DESCRIPTIONS:
Main Water Valve Location • Location: Exterior Front
Supply Piping • Copper Pipe
Drain/Waste/Vent • Galvanized Steel • Cast Iron
Main Gas Valve Location • Exterior Side
Water Heaters • Manufacturer: A.O. Smith • Capacity: 50 Gallons • Approximate Age (years): 5 • Gas
• Location: Laundry
Seismic Gas Shut-off • Not Present
Excess Flow Gas Shut-off • Not Present
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 19 of 27777 Rustic Lane, Mountain View
Illustration 5B
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 20 of 27777 Rustic Lane, Mountain View
Interior
COMMENTS:
RECOMMENDATIONS/OBSERVATIONS - '!' indicates an immediate improvement recommendation item.
INTERIOR
The mirror on the front left bedroom closet door is cracked/damaged. We recommend replacement. (See Photo 13)! 1.
The openings in the railing are larger than 4". For improved safety it is recommended that the railing be altered for an
opening of less than 4". (See Illustration 7B) (See Photo 17)
! 2.
Cracked, deteriorated and/or missing floor tile grout and caulk in various areas should be replaced. Water leaking
through non-sealed areas can cause damage. Damage caused by water seepage cannot be determined by this visual
inspection.
3.
Holes were noted in one or more of the interior walls near the doors. This condition appears to be caused by the door
knobs. We recommend installation of door stops and the wall surface be repaired and refinished to restore its
appearance.
4.
There is evidence of Vermin activity in the structure. It is likely that this infestation is also in inaccessible areas. The
owner is advised to contact the appropriate tradesperson for any remedial measures necessary.
5.
BATHROOMS
Cracked shower wall tile in the hall bathroom should be replaced. Water leaking through non-sealed areas can cause
damage. Damage caused by water seepage cannot be determined by visual observation. (See Photo 12)
! 6.
The escutcheons at the master bathroom shower faucet, spout or shower head are loose. We recommend tightening
and/or sealing this trim piece for a better appearance and to avoid leakage in this area. (See Photo 15)
! 7.
The hall bathroom and master bathroom sink basin shows evidence of heavy wear, chipping and/or cosmetic
cracking. This is primarily a cosmetic condition, however it may be desirable to refinish or replace it for cosmetic
considerations and/or prolong the life of the sink.
8.
Cracked, deteriorated and/or missing grout and caulk in the hall bathroom and master bathroom shower should be
replaced. Water leaking through non-sealed areas can cause damage. Damage caused by water seepage cannot be
determined by this visual observation. A flexible caulking material is recommended rather than rigid cementious grout.
9.
OTHER/MISC.
California law requires that all homes have a State Fire Marshall approved Carbon Monoxide Detector installed
outside of the sleeping quarters and on each level of the home. At the time of this inspection a Carbon Monoxide
Detector was located. As a carbon monoxide detector was not noted in all of the recommended locations additional
detectors should be installed.
! 10.
Generally speaking, the kitchen is in good condition.
Generally speaking, the bathroom(s) are in good condition.
The interior finishes of the home are considered to be in good condition.
All appliances that were tested appear to be in good condition and responded satisfactorily.
The windows and doors are of good quality.
ITEM DESCRIPTIONS:
Kitchen Appliances Tested • Built in Electric Oven • Electric Cooktop • Microwave • Dishwasher • Waste Disposer •
Exhaust Hood
Laundry Facilities/Hookup • 240 Volt Circuit for Dryer • 120 Volt Circuit for Washer • Gas Piping for Dryer • Hot
and Cold Water Supply for Washer • Waste Standpipe for Washer • Dryer vent noted
Wall Finishes • Drywall/Plaster
Ceiling Finishes • Drywall/Plaster
Floor • Tile/Stone • Vinyl
Doors • Hollow Core • Raised Panel • French • Sliding
Window style and Glazing • Casement • Sliders • Fixed Pane • Double Pane
Fireplace/Wood Stove • Zero Clearance • Gas
Other Componets Inspected • Smoke Detector • Door Bell
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 21 of 27777 Rustic Lane, Mountain View
ENVIROMENTAL ISSUES:
Issues Based on the age of this home, there is a possibility the structure may contain asbestos such as ceiling
texture, insulation on the distribution piping and/or transit piping and siding. This can only be verified by laboratory
analysis. The Environmental Protection Agency (E.P.A.) reports that asbestos represents a health hazard if “friable”
damaged, crumbling, or in any state that allows the release of fibers. If replacement necessitates the removal of the
acoustic ceiling or insulation, a specialist should be engaged. If any sections of this insulation are indeed friable, or
become friable over time, a specialist should be engaged. Further guidance is available from the Environmental
Protection Agency (E.P.A.). Due to the age of construction, it is likely that there are other materials within the home
that contain asbestos but are not identified by this inspection report.
11.
Carbon monoxide is a colorless, odorless gas that can result from a faulty fuel burning furnace, range, water heater,
space heater or wood stove. Proper maintenance of these appliances is the best way to reduce the risk of carbon
monoxide poisoning. For more information, consult the Consumer Product Safety Commission CPSC at
www.cpsc.gov for further guidance.
12.
MAINTENANCE ITEMS & GENERAL INFORMATION
INTERIOR
The evaluation of the thermal pane windows ("dual pane/glazed") is limited to accessible windows exhibiting
noticeable conditions at the time of our inspection, such as condensation and/or evidence of moisture developing
between the panes of glass. Due to the known design and/or characteristics associated with thermal pane windows,
conditions may be discovered at a later date, however seal failure can occur at any time.
13.
KITCHEN
Testing of the oven cleaning function is beyond the scope of this inspection. For proper operation and testing of this
function we recommend consultation with the existing homeowner.
14.
The adequacy of the fireplace draw cannot be determined during a visual inspection.•
The operation of the dishwasher was limited to a filling and draining cycle only, however due to time limitations timers,
dryer cycles and/or higher functions were not tested. For additional information in regards to the operation and full
function of the dishwasher we recommend consultation with the owner or appropriate trades.
•
The fireplace was visually inspected however the gas burner was not tested.•
Furniture, storage, appliances and/or wall hangings restricted the inspection of the interior.•
No access was gained to the wall cavities of the home.•
Kitchen appliances were operated unless noted otherwise. However they were not inspected for installation according
to manufacturer specifications and were not evaluated for performance, efficiency or adequacy during their operation.
No refrigerators whether "built in" or portable are operated, inspected or tested.
•
All appliances not "built in" to the structure such as washing machine, dryer, refrigerator and/or countertop microwaves
were not inspected and are excluded from this report. No refrigerators whether "built in" or portable are operated,
inspected or tested.
•
Fireplace screens or doors were not inspected and are excluded from this report•
This is a visual inspection to the accessible areas only. Assessing the quality of interior finishes is highly subjective.
Issues such as cleanliness, cosmetic flaws, quality of materials, architectural appeal and color are outside the scope of
this inspection. Comments are general, except where functional concerns exist. Due to texturing and painting of interior
surfaces there is no possible way of determining point of origin of any gypsum (sheetrock) material without destructive
testing. HomeGuard Incorporated does not perform any destructive testing. Smoke detectors and carbon monoxide
detectors were not manually tested. The sensors of these units are not tested. Both smoke detectors and carbon
monoxide detectors have a limited life span and should be replaced according to the manufactures instructions.
LIMITATIONS:
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 22 of 27777 Rustic Lane, Mountain View
Illustration 7B
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 23 of 27777 Rustic Lane, Mountain View
Photographs
No relative importance should be placed on the photographs provided in this report. The photographs in this
report do not necessarily illustrate all of the damage in any particular finding. Also, not all problem areas will
be supported with photographs. Please contact HomeGuard if you have any questions.
Photo 1 Photo 2
Photo 3 Photo 4
Photo 5 Photo 6
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 24 of 27777 Rustic Lane, Mountain View
Photo 7 Photo 9
Photo 10 Photo 11
Photo 12 Photo 13
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 25 of 27777 Rustic Lane, Mountain View
Photo 14 Photo 15
Photo 17 Photo 18
Photo 19 Photo 20
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 26 of 27777 Rustic Lane, Mountain View
Maintenance Advice
UPON TAKING OWNERSHIP
After taking ownership of a new home, there are some maintenance and safety issues that should be addressed
immediately. The following checklist should help you undertake these improvements.
Change the locks on all exterior entrances, for improved security.
Check that all windows and doors are secure. Improve window hardware as necessary. Security rods can be added
to sliding windows and doors. Considerations could also be given to a security system.
Install smoke detectors on each level of the home. Ensure that there is a smoke detector outside all sleeping areas.
Replace batteries on any existing smoke detectors and test them. Make a note to replace batteries again in one year.
Create a plan of action in the event of a fire in your home. Ensure that there is an operable window or door in
every room of the house. Consult with your local fire department regarding fire safety issues and what to do in
the event of a fire.
Examine driveways and walkways for trip hazards. Undertake repairs where necessary.
Examine the interior of the home for trip hazards. Loose or torn carpeting and flooring should be repaired.
Undertake improvements to all stairways, decks, porches and landings where there is a risk of falling or stumbling.
Review your home inspection report for any items that require immediate improvement or further investigation.
Address these areas as required.
Install rain caps and vermin screens on all chimney flues, as necessary.
Investigate the location of the main shut-offs for the plumbing, heating and electrical systems. If you attend the home
inspection, these items have been pointed out to you.
REGULAR MAINTENANCE
EVERY MONTH
Check that fire extinguisher(s) are fully charged. Re-charge if necessary.
Examine heating/cooling air filters and replace or clean as necessary.
Inspect and clean humidifiers and electronic air cleaners.
If the house has hot water heating, bleed radiator valves.
Clean gutters and downspouts. Ensure that downspouts are secure, and that the discharge of the downspouts is
appropriate. Remove debris from window wells.
Carefully inspect the condition of shower enclosures. Repair or replace deteriorated grout and caulk. Ensure that
water is not escaping the enclosure during showering. Check below all plumbing fixtures for evidence of leakage.
Repair or replace leaking faucets or shower heads.
Secure loose toilets, or repair flush mechanisms that become troublesome.
SPRING AND FALL
Examine the roof for evidence of damage to roof covering, flashings and chimneys.
Look in the attic (if accessible) to ensure that roof vents are not obstructed. Check for evidence of leakage,
condensation or vermin activity. Level out insulation if needed.
Trim back tree branches and shrubs to ensure that they are not in contact with the house.
Inspect the exterior walls and foundation for evidence of damage, cracking or movement. Watch for bird nests or other
vermin or insect activity.
Survey the basement and/or crawl space walls for evidence of moisture seepage.
Look at overhead wires coming to the house. They should be secure and clear of trees or other obstructions.
Ensure that the grade of the land around the house encourages water to flow away from the foundation.
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
Page 27 of 27777 Rustic Lane, Mountain View
Inspect all driveways, walkways, decks, porches, and landscape components for evidence of deterioration, movement
or safety hazards.
Clean windows and test their operation. Improve caulking and weather-stripping as necessary. Watch for evidence
of rot in wood windows frames. Paint and repair window sills and frames as necessary.
Test all ground fault circuit interrupter (GFCI) devices, as identified in the inspection report.
Shut off isolating valves for exterior hose bibs in the fall, if below freezing temperatures are anticipated.
Test the Temperature and Pressure Relief (TPR) Valve on water heaters.
Inspect for evidence of wood boring insect activity. Eliminate any wood/soil contact around the perimeter of the home.
Test the overhead garage door opener, to ensure that the auto-reverse mechanism is responding properly. Clean and
lubricate hinges, rollers and tracks on overhead doors.
Replace or clean exhaust hood filters.
Clean, inspect and/or service all appliances as per the manufacturer's recommendations.
ANNUALLY
Replace smoke detector batteries.
Have the heating, cooling and water heater systems cleaned and serviced.
Have chimneys inspected and cleaned. Ensure that rain caps and vermin screens are secure.
Examine the electrical panels, wiring and electrical components for evidence of overheating. Ensure that all
components are secure. Flip the breakers on and off to ensure that they are not sticky.
If the house utilizes a well, check and service the pump and holding tank. Have the water quality tested. If the
property has a septic system, have the tank inspected (and pumped as needed).
If your home is in an area prone to wood destroying insects (termites, carpenter ants, etc.), have the home
inspected by a licensed specialist. Preventive treatments may be recommended in some cases.
PREVENTION IS THE BEST APPROACH
Although we've heard it many times, nothing could be more true than the old cliche "an ounce of prevention is worth a
pound of cure." Preventative maintenance is the best way to keep your house in great shape. It also reduces the risk of
unexpected repairs and improves the odds of selling your house at fair market value, when the time comes.Please feel free to contact our office should you have any questions regarding the operation or maintenance of your
home. Enjoy your home!
q
q
q
q
q
q
q
q
q
q
q
q
q
q
q
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958
$555.00
Invoice No: LIV553925P
Report No: 438958 TPR
Invoice Date: 2/14/2018
Inspection: 2/13/2018
Address: 777 Rustic Lane
Mountain View CA, 94040
Escrow#:
Debbie Blackwell
777 Rustic Lane
Mountain View, CA 94040
Invoice
Property Information:
Bill To:
Billing Information:
DUE UPON RECEIPT
Complete
Total Due: $555.00
HomeGuardIncorporated
Please remit to 510 Madera Ave., San Jose, CA 95112
There is a $25 fee for all returned checks
HomeGuard Incorporated 510 Madera Avenue, San Jose, CA 95112 (855) 331-1900 Report No. 438958