QUICK START GUIDE AIRASSURE™ INDOOR PM2.5 MASS CONCENTRATION MONITOR MODEL IPM2.5 1. Prepare Wall

Transcript of Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured...

Page 1: Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured monitor to appear on AirAssure Web Application and refresh the web page. AirAssure TSI

QUICK START GUIDE AIRASSURE™ INDOOR PM2.5 MASS

CONCENTRATION MONITOR MODEL IPM2.5

1. Prepare Wall

Page 2: Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured monitor to appear on AirAssure Web Application and refresh the web page. AirAssure TSI

2. Mount Monitor

Without Wall Plate With Wall Plate

–2–

Page 3: Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured monitor to appear on AirAssure Web Application and refresh the web page. AirAssure TSI

3. Install Web Application Java®, Tomcat™ and AirAssure Web

Download and open installation

package. http://www.tsi.com/airassure-get-started-en

-3-

Page 4: Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured monitor to appear on AirAssure Web Application and refresh the web page. AirAssure TSI

4. Open Tomcat™ Application Manager Interface

a. Open web browser http://localhost:8080/manager

or http://IPADDRESS:8080/manager “IPADDRESS” = address of server.

b. Browse for pmweb.war

c. Record Tomcat IP Server Address d. Click on /pmweb to open application

–4–

Page 5: Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured monitor to appear on AirAssure Web Application and refresh the web page. AirAssure TSI

5. AirAssure Monitor IP Configuration

a. Connect instrument to 24V power and Ethernet connection.

b. Record IP Address

c. Open web browser by entering

AirAssure IP Address on computer connected to same network.

d. Enter serial number of monitor as password and click Login.

e. Enter Tomcat Server IP address. f. Click Submit Changes and Apply

Changes to power-cycle the monitor.

g. Repeat for all monitors to be

configured.

-5-

Page 6: Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured monitor to appear on AirAssure Web Application and refresh the web page. AirAssure TSI

h. Refresh or re-open AirAssure Web withthe Application to view each monitor.

i. Wait up to 5 minutes for eachconfigured monitor to appear onAirAssure Web Application and refreshthe web page.

AirAssure

poraTSI Incor ted – Visit our website www.tsi.com for more information.

USA Tel: +1 800 874 2811 UK Tel: +44 149 4 459200

France el: +33 1 41 19 21 99 T TGermany el: +49 241 523030

India Tel: +91 80 67877200 China Tel: +86 10 8219 7688 Singapore Tel: +65 6595 6388

P/N 6008420 Rev D ©2016 TSI Incorporated Printed in U.S.A.

Page 7: Home | TSI - AIRASSURE™ INDOOR PM2.5 MASS ......i. Wait up to 5 minutes for each configured monitor to appear on AirAssure Web Application and refresh the web page. AirAssure TSI

Outline of Device – Do Not Cut

CUTOUT

CUTOUT

CU

TOU

T

CU

TOU

T

DRILL 4.5mm HOLE

DRILL 4.5mm HOLES

66mm

50mm

135mm

41mm

8mm

MODEL IPM2.5 WALL MOUNT TEMPLATE

INSTRUCTIONS 1. Tape to wall, use level to straighten2. Use center punch or sharp tool to

mark hole locations and cutoutcorners

3. Remove template4. Drill holes though drywall and cut

rectangular hole5. Refer to manual for install

instructions

P/N 6008420 Rev. D © 2016 TSI Incorporated