Page 1: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

*

www.redbrickinspections.ca

[email protected]

416-829-6655

*please see credentials at end of report

HOME INSPECTION REPORT

Inspection Date: April 23 2015

Kevin Alvarez

Prepared by:

6245 Prarie Circle

Mississauga

Bob Papadopoulos P.Eng., RHI

Prepared for:

Page 2: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle page 1

SIGNIFICANT ITEMSThis page should not be considered as the complete report. For the purposes of this report,

Please read all other forms and appropriate Reference# the front of the house is considered

in the Home Reference Book. to be facing:

ROOFING

EXTERIOR

STRUCTURE

ELECTRICAL

HEATING

COOLING/HEAT PUMPS

INSULATION/VENTILATION

PLUMBING

INTERIOR

���� ���� ���� ���� ���� ���� ���� ���� ����

Below Typical Typical Above Typical

Overall good water pressure with copper supply piping. The washrooms have recently

been renovated.

Overall well maintained.

2-yr-old high-efficiency forced-air gas furnace with a typical life expectancy of 20-yrs.

The air-conditioner is older. Continue servicing until replacement becomes necessary.

Overall well built house

April 23 2015

The following rating reflects both the original quality of construction and the overall current condition of the

home, based on a comparison to similar homes.

OVERALL RATING

Mississauga SUMMARY

West

Approx 10-yr-old asphalt shingles with a typical life expectancy of 15-20-yrs.

The 100 AMP service size is adequate and the wiring is copper.

Limited access though where visible appears to be adequate.

See details for general repairs and maintenance.

Prior to reviewing the Home Inspection Report please read the Terms and Conditions of the Home

Inspection and the Standards of Practice of the Canadian Association of Home and Property Inspectors

available online at www.redbrickinspections.ca.

Page 3: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle ROOFING/Chimneys page 2

Description

1.0 Roofing Material: Location: 4.0 Leakage Probability:

Limitations

Roof Inspected By: Chimney Access Limited By:

Ref#* Observations/Recommendations

overall surface in good repair

overall in good repair, one rusting unit though typical

Note: Recommend Annual Maintenance Contract for Roof Surface, Flashing Details and Chimney(s)

1.0 Roofing:

Sloped Surface:

Slope:

April 23 2015

3.0 Chimney(s) Type:

Metal:

Access Limited By:

NorthMedium

Location:

Asphalt Shingles:

Walking On

3.0 Chimney(s):

Page 4: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle page 3

Description

1.0 Gutters & Downspouts: 2.0 Lot Topography:

Limitations

Ref#* Observations/Recommendations

require maintenance

re-grade and slope way from house

overall in good repair, window sills require repairs on south side

require general maintenance

minor settlement - monitor, could not determine time of support system

column is loose rotted at base - requires repair, step settlement, overall

requires repairs

old, cracking, settlement, budget to re-surface

fence repairs required

Note: Maintain Gutters & Downspouts annually. Extend Downspouts at least 6-feet away from the house

** Any or all these items may contribute to Basement Leakage. Please see Interior Form

**1.0 Gutters/Downspouts:

Various Above Grade

EXTERIOR April 23 2015

Exterior Inspection from Ground Level

Brick

3.0 WALL SURFACES:

Brick:

4.0 DOORS/WINDOWS:

**7.0 Driveway(s):

3.0 Walls & 9.0 Wall Structures:

FlatAluminum:

Garage Not Accessible

5.0 DECK

5.0 PORCH

Downspout(s) Discharge:

Comments:

**2.0 Lot Grading:

**North Grading:

Page 5: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle page 4

Description

2.0 Configuration: 4.0 Foundations: 5.0 Floor : 6.0 Walls : 7.0 Roof/Ceiling Framing:

Limitations

Foundation Wall Not Visible: 90 %

Ref#* Observations/Recommendations

typical settlement cracks

overall in good repair

Wood Frame(Brick Veneer)

Restricted Access to:

Wood Joists

Roof Space Inspected From Access HatchWall Space

STRUCTURE

Basement: Poured Concrete Wood Trusses

April 23 2015

4.0 FOUNDATIONS:

7.0 ROOF:

Page 6: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle page 5

Description

AMP (240volts) 2.2 Service Entrance Cable: 4.0 Distribution Wire:

2.4 Main Disconnect/Service Box Location:

Rating: 100 AMP Type of material:

Description:

Location:

3.0 Distribution Panel 2.5 System Grounding:

Rating: 100 AMP Description:

Description: Location: 2.5 Ground Fault Circuit Interrupter:

Location: Location:

Auxiliary Panel(s): 5.1 Outlets

Rating: AMP Description:

Description: Number of Outlets: 3.5 Arc Fault Circuit Interrupter:

Location: Location:

Limitations

Ref#* Observations/Recommendations

overall in good repair

provide to exterior outlet

provide to washroom outlet

loose wire at rear exterior - should be capped and secured or remove if

not rated for exterior use

Note 1: All recommendations are safety issues - Treat them as high priority.

Note 2: Please ensure accurate labeling on panels.

Main Disconnect Cover Not Removed

April 23 2015

100

Grounded

Typical

Bathroom(s)

5.0 ELECTRICAL DEVICES

GFCI:

Kitchen

Breakers

Basement

Basement

2.3 Service Size:

ELECTRICAL

Breakers

Underground

Not Visible

Copper

Water Pipe

Copper

Panel

Wiring:

3.0 SERVICE PANEL:

Page 7: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle page 6

Description

Description: Efficiency: Approx. Age: Life Expectancy: 2.0 Fuel: Shut Off at:

69 2 yrs. 20 yrs.

Limitations

Ref#* Observations/Recommendations

service annually

Rated Input:

HEATING

Heat Exchanger- Inaccessible

Meter-Exterior

April 23 2015

x1000BTU/hr GasHigh

Heat Loss Calculations Not Done

Exhaust Vent Arrangement: Plastic Through-Wall Vent

5.0 FORCED AIR FURNACE:

Forced Air Furnace:

Page 8: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle COOLING/Heat Pumps page 7

Description

1.0 Description: 1.4 Cooling Capacity: 1.5 Approx. Age: Typical Life Expectancy:

24 24 15 yrs.

Limitations Cooling Performance

Ref#* Observations/Recommendations

not tested: should be serviced before using

April 23 2015

Cannot Test With Low Outdoor Temp Supply Temp F:

Return Temp F:

1.0 AIR CONDITIONER:

1.0 Air Conditioner (air-cooled): x1,000 BTU/hr yrs. old

Page 9: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle INSULATION/VENTILATION page 8

Description

2.0 Material: 3.0 Location

32

12

Limitations

Ref#* Observations/Recommendations

insulation and ventilation is adequate

Note: adding insulation is considered an improvement rather than a repair

3.0 ROOF SPACE:

April 23 2015

R-Value

Roof

Roof Soffit

Access Not Gained To Wall Space

6.1 Venting:

Cellulose:

Roof Space Inspected from Access Hatch

Basement Walls:Fiberglass:

Main Roof:

Basement Walls Spot Checked Only

Plastic

5.0 Air/Vapour Barrier:

Page 10: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle page 9

Description

1.0 Service Piping into House: 1.3 Main Shut Off Valve at: Water Flow (Pressure):

1.4 Supply Piping&Pump(s): 2.0 Waste Piping&Pump(s): 1.6 Water Heater

Type:

Fuel Type:

Capacity:

Age Yrs.: 7

Life Expectancy: 15

Limitations

Ref#* Observations/Recommendations

near toilet, odour noted when toilet flushed, typically floor

drain should not be located this close to toilet

Tub/Sink Overflows Not Tested

Concealed Plumbing not Inspected

Copper Plastic

Conventional

Gas

40 Gal

April 23 2015PLUMBING

Kitchen and Laundry Appliances Were Not Inspected

Basement Good

Isolating/Relief Valves & Main Shut Off Valves Not Tested

Copper

2.0 WASTE PIPING:

Basement Floor Drain:

Page 11: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

6245 Prarie Circle page 10

Description

1.0 Floor Finishes: 2.0 Wall Finishes: 3.0 Ceiling Finishes: 6.0 Windows: 7.0 Exterior Doors:

Limitations

Restricted/No Access To: Foundation Not Visible 90 %

CO Detectors,Security Systems, Central Vacuum,Chimney Flues Not Inspected Drainage Tile Not Visible

Ref#* Observations/Recommendations

presently under renovation in some areas

screen missing

missing screen - required

recommend chimney sweep/inspection by W.E.T.T. Certified technician

(www.wettinc.ca)

typical efflorescence, staining and dampness for older foundation

some evidence of past leaking on north side

see steps below

please ensure one per level each with annual maintenance, this is a life

safety concern and mandatory by law

** Steps recommended in order to minimize basement leakage (read Section 10):

1. gutters, downspouts, grading, driveways: ongoing maintenance and repair/see Exterior

2. cracks/form ties on foundation: monitor/repair as required

3. excavation/damp-proofing: monitor basement, consider step 3 as a last resort

INTERIOR April 23 2015

11. CO/Smoke detectors:

Drywall Drywall Sliders Metal

Fixed

Single/Double Hung

Sliding Glass

Wood

9.0 FIREPLACE:

**10.0 Basement Leakage:

Resilient

Carpet

1.0 Floors:

Sliding Door:

8.0 Fireplaces:

Zero Clearance

9.0 Fireplace Fuel:

Wood

Page 12: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects

Bob Papadopoulos P.Eng, RHI

• Over 14 years of building inspecting experience in Toronto and the GTA

• Over 4,000 residential and commercial buildings inspected

Professional Designations

• P.Eng. (Professional Engineer of Ontario)

• RHI Registered Home Inspector

• Certified Energy Auditor

Bob has inspected over 4,000 residential and commercial buildings of various

descriptions and reporting on conditions of major systems including structure,

building envelope and mechanical systems, specific problem investigations and

pre-renovation inspections. In the past Bob has helped train Home Inspectors

and assisted in the creation of educational courses on home inspecting as well

as taught Home Inspection courses at Seneca College. Bob also has experience

in the construction industry inspecting many large scale projects through-out the

GTA. He also served in the Canadian Navy as a Marine Mechanic and Ships

Team Diver.