HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement...
Transcript of HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement...
![Page 1: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/1.jpg)
*
www.redbrickinspections.ca
416-829-6655
*please see credentials at end of report
HOME INSPECTION REPORT
Inspection Date: April 23 2015
Kevin Alvarez
Prepared by:
6245 Prarie Circle
Mississauga
Bob Papadopoulos P.Eng., RHI
Prepared for:
![Page 2: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/2.jpg)
6245 Prarie Circle page 1
SIGNIFICANT ITEMSThis page should not be considered as the complete report. For the purposes of this report,
Please read all other forms and appropriate Reference# the front of the house is considered
in the Home Reference Book. to be facing:
ROOFING
EXTERIOR
STRUCTURE
ELECTRICAL
HEATING
COOLING/HEAT PUMPS
INSULATION/VENTILATION
PLUMBING
INTERIOR
���� ���� ���� ���� ���� ���� ���� ���� ����
Below Typical Typical Above Typical
Overall good water pressure with copper supply piping. The washrooms have recently
been renovated.
Overall well maintained.
2-yr-old high-efficiency forced-air gas furnace with a typical life expectancy of 20-yrs.
The air-conditioner is older. Continue servicing until replacement becomes necessary.
Overall well built house
April 23 2015
The following rating reflects both the original quality of construction and the overall current condition of the
home, based on a comparison to similar homes.
OVERALL RATING
Mississauga SUMMARY
West
Approx 10-yr-old asphalt shingles with a typical life expectancy of 15-20-yrs.
The 100 AMP service size is adequate and the wiring is copper.
Limited access though where visible appears to be adequate.
See details for general repairs and maintenance.
Prior to reviewing the Home Inspection Report please read the Terms and Conditions of the Home
Inspection and the Standards of Practice of the Canadian Association of Home and Property Inspectors
available online at www.redbrickinspections.ca.
![Page 3: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/3.jpg)
6245 Prarie Circle ROOFING/Chimneys page 2
Description
1.0 Roofing Material: Location: 4.0 Leakage Probability:
Limitations
Roof Inspected By: Chimney Access Limited By:
Ref#* Observations/Recommendations
overall surface in good repair
overall in good repair, one rusting unit though typical
Note: Recommend Annual Maintenance Contract for Roof Surface, Flashing Details and Chimney(s)
1.0 Roofing:
Sloped Surface:
Slope:
April 23 2015
3.0 Chimney(s) Type:
Metal:
Access Limited By:
NorthMedium
Location:
Asphalt Shingles:
Walking On
3.0 Chimney(s):
![Page 4: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/4.jpg)
6245 Prarie Circle page 3
Description
1.0 Gutters & Downspouts: 2.0 Lot Topography:
Limitations
Ref#* Observations/Recommendations
require maintenance
re-grade and slope way from house
overall in good repair, window sills require repairs on south side
require general maintenance
minor settlement - monitor, could not determine time of support system
column is loose rotted at base - requires repair, step settlement, overall
requires repairs
old, cracking, settlement, budget to re-surface
fence repairs required
Note: Maintain Gutters & Downspouts annually. Extend Downspouts at least 6-feet away from the house
** Any or all these items may contribute to Basement Leakage. Please see Interior Form
**1.0 Gutters/Downspouts:
Various Above Grade
EXTERIOR April 23 2015
Exterior Inspection from Ground Level
Brick
3.0 WALL SURFACES:
Brick:
4.0 DOORS/WINDOWS:
**7.0 Driveway(s):
3.0 Walls & 9.0 Wall Structures:
FlatAluminum:
Garage Not Accessible
5.0 DECK
5.0 PORCH
Downspout(s) Discharge:
Comments:
**2.0 Lot Grading:
**North Grading:
![Page 5: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/5.jpg)
6245 Prarie Circle page 4
Description
2.0 Configuration: 4.0 Foundations: 5.0 Floor : 6.0 Walls : 7.0 Roof/Ceiling Framing:
Limitations
Foundation Wall Not Visible: 90 %
Ref#* Observations/Recommendations
typical settlement cracks
overall in good repair
Wood Frame(Brick Veneer)
Restricted Access to:
Wood Joists
Roof Space Inspected From Access HatchWall Space
STRUCTURE
Basement: Poured Concrete Wood Trusses
April 23 2015
4.0 FOUNDATIONS:
7.0 ROOF:
![Page 6: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/6.jpg)
6245 Prarie Circle page 5
Description
AMP (240volts) 2.2 Service Entrance Cable: 4.0 Distribution Wire:
2.4 Main Disconnect/Service Box Location:
Rating: 100 AMP Type of material:
Description:
Location:
3.0 Distribution Panel 2.5 System Grounding:
Rating: 100 AMP Description:
Description: Location: 2.5 Ground Fault Circuit Interrupter:
Location: Location:
Auxiliary Panel(s): 5.1 Outlets
Rating: AMP Description:
Description: Number of Outlets: 3.5 Arc Fault Circuit Interrupter:
Location: Location:
Limitations
Ref#* Observations/Recommendations
overall in good repair
provide to exterior outlet
provide to washroom outlet
loose wire at rear exterior - should be capped and secured or remove if
not rated for exterior use
Note 1: All recommendations are safety issues - Treat them as high priority.
Note 2: Please ensure accurate labeling on panels.
Main Disconnect Cover Not Removed
April 23 2015
100
Grounded
Typical
Bathroom(s)
5.0 ELECTRICAL DEVICES
GFCI:
Kitchen
Breakers
Basement
Basement
2.3 Service Size:
ELECTRICAL
Breakers
Underground
Not Visible
Copper
Water Pipe
Copper
Panel
Wiring:
3.0 SERVICE PANEL:
![Page 7: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/7.jpg)
6245 Prarie Circle page 6
Description
Description: Efficiency: Approx. Age: Life Expectancy: 2.0 Fuel: Shut Off at:
69 2 yrs. 20 yrs.
Limitations
Ref#* Observations/Recommendations
service annually
Rated Input:
HEATING
Heat Exchanger- Inaccessible
Meter-Exterior
April 23 2015
x1000BTU/hr GasHigh
Heat Loss Calculations Not Done
Exhaust Vent Arrangement: Plastic Through-Wall Vent
5.0 FORCED AIR FURNACE:
Forced Air Furnace:
![Page 8: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/8.jpg)
6245 Prarie Circle COOLING/Heat Pumps page 7
Description
1.0 Description: 1.4 Cooling Capacity: 1.5 Approx. Age: Typical Life Expectancy:
24 24 15 yrs.
Limitations Cooling Performance
Ref#* Observations/Recommendations
not tested: should be serviced before using
April 23 2015
Cannot Test With Low Outdoor Temp Supply Temp F:
Return Temp F:
1.0 AIR CONDITIONER:
1.0 Air Conditioner (air-cooled): x1,000 BTU/hr yrs. old
![Page 9: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/9.jpg)
6245 Prarie Circle INSULATION/VENTILATION page 8
Description
2.0 Material: 3.0 Location
32
12
Limitations
Ref#* Observations/Recommendations
insulation and ventilation is adequate
Note: adding insulation is considered an improvement rather than a repair
3.0 ROOF SPACE:
April 23 2015
R-Value
Roof
Roof Soffit
Access Not Gained To Wall Space
6.1 Venting:
Cellulose:
Roof Space Inspected from Access Hatch
Basement Walls:Fiberglass:
Main Roof:
Basement Walls Spot Checked Only
Plastic
5.0 Air/Vapour Barrier:
![Page 10: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/10.jpg)
6245 Prarie Circle page 9
Description
1.0 Service Piping into House: 1.3 Main Shut Off Valve at: Water Flow (Pressure):
1.4 Supply Piping&Pump(s): 2.0 Waste Piping&Pump(s): 1.6 Water Heater
Type:
Fuel Type:
Capacity:
Age Yrs.: 7
Life Expectancy: 15
Limitations
Ref#* Observations/Recommendations
near toilet, odour noted when toilet flushed, typically floor
drain should not be located this close to toilet
Tub/Sink Overflows Not Tested
Concealed Plumbing not Inspected
Copper Plastic
Conventional
Gas
40 Gal
April 23 2015PLUMBING
Kitchen and Laundry Appliances Were Not Inspected
Basement Good
Isolating/Relief Valves & Main Shut Off Valves Not Tested
Copper
2.0 WASTE PIPING:
Basement Floor Drain:
![Page 11: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/11.jpg)
6245 Prarie Circle page 10
Description
1.0 Floor Finishes: 2.0 Wall Finishes: 3.0 Ceiling Finishes: 6.0 Windows: 7.0 Exterior Doors:
Limitations
Restricted/No Access To: Foundation Not Visible 90 %
CO Detectors,Security Systems, Central Vacuum,Chimney Flues Not Inspected Drainage Tile Not Visible
Ref#* Observations/Recommendations
presently under renovation in some areas
screen missing
missing screen - required
recommend chimney sweep/inspection by W.E.T.T. Certified technician
(www.wettinc.ca)
typical efflorescence, staining and dampness for older foundation
some evidence of past leaking on north side
see steps below
please ensure one per level each with annual maintenance, this is a life
safety concern and mandatory by law
** Steps recommended in order to minimize basement leakage (read Section 10):
1. gutters, downspouts, grading, driveways: ongoing maintenance and repair/see Exterior
2. cracks/form ties on foundation: monitor/repair as required
3. excavation/damp-proofing: monitor basement, consider step 3 as a last resort
INTERIOR April 23 2015
11. CO/Smoke detectors:
Drywall Drywall Sliders Metal
Fixed
Single/Double Hung
Sliding Glass
Wood
9.0 FIREPLACE:
**10.0 Basement Leakage:
Resilient
Carpet
1.0 Floors:
Sliding Door:
8.0 Fireplaces:
Zero Clearance
9.0 Fireplace Fuel:
Wood
![Page 12: HOME INSPECTION REPORT · The air-conditioner is older. Continue servicing until replacement becomes necessary. Overall well built house April 23 2015 The following rating reflects](https://reader034.fdocuments.us/reader034/viewer/2022042810/5f9ce9cbf12f3e0c71098065/html5/thumbnails/12.jpg)
Bob Papadopoulos P.Eng, RHI
• Over 14 years of building inspecting experience in Toronto and the GTA
• Over 4,000 residential and commercial buildings inspected
Professional Designations
• P.Eng. (Professional Engineer of Ontario)
• RHI Registered Home Inspector
• Certified Energy Auditor
Bob has inspected over 4,000 residential and commercial buildings of various
descriptions and reporting on conditions of major systems including structure,
building envelope and mechanical systems, specific problem investigations and
pre-renovation inspections. In the past Bob has helped train Home Inspectors
and assisted in the creation of educational courses on home inspecting as well
as taught Home Inspection courses at Seneca College. Bob also has experience
in the construction industry inspecting many large scale projects through-out the
GTA. He also served in the Canadian Navy as a Marine Mechanic and Ships
Team Diver.
http://www.peo.on.ca/
http://www.oahi.com/