Home Elevators - PlanningGuidehomeelevatorsandiegocounty.com/_downloads/Advantage...Home Elevator...
Transcript of Home Elevators - PlanningGuidehomeelevatorsandiegocounty.com/_downloads/Advantage...Home Elevator...
A LOCAL COMPANY WITH A TEAM OF PROFESSIONALS PROVIDING EFFICIENT SERVICE
TO SAN DIEGO AND ORANGE COUNTIES
WE ALSO SELL, SERVICE AND INSTALL:
WARRANTYManufacturer’s warranty for parts is two years
for new elevators. Our labor warranty is two years, the longest in the industry.
SERVICEIf you need a repair after the warranty period
expires, our labor rates are reasonable. All parts and labor include a 90-day warranty. Yearly maintenance contracts are available.
INSURANCEWorkers Compensation #9160224 State Fund
Liability Insurance #VOG 0001753 SF QGCG 2373321C
Phone: 858.678.8780 • Fax: 442.244.0014Robert Ingram • 619.994.3794 Cell
Andy Freeburn, BSEE • 619.770.9475 Cell [email protected]
7017 Ivy Street • Carlsbad, CA 92011 C11 Contractors License #1027832
PlanningGuide
Page �0
Counterweighted Chain Drive Overview
Frequency controlled variable speed geared machine with counterweighted chain drive
Electrical controller-Can be located remotely within 50'
Car operating panel
Handrail
Recessed lights
Counterweights
Floor selector magnet assembly
Two #60 roller chains
Modular rail system
Wiring raceway for interlocks and hall stations
White ceiling panel
Melamine, wood veneer, inset wood veneer or raised panel
wood walls
Interlocking wall system
Plywood floor with removable insert for 3/4" thick finished floor
115 and �30 volt auxiliary disconnects
ThyssenKrupp Access Manufacturing LLC4001 East 138th Street
Grandview, MO 64030-2837Phone: 816-763-3100
Fax: 816-763-4467Sales: 800-669-9047
www.thelev.comwww.tkaccess.com7.5M0808-IM398
This Advantage MRL* Elevator is our most popular model. Made in Los Angeles with generic parts it is a great value!
*MRL= Machine Roomless. All components are in the shaftway.
Requires 8” Pit
Requires 24” above cab for motor and controller
Planning Guide
3
Questions? 858.678.8780
Common Hoistway Configurations 4
Typical Hoistway Dimensions 4
Door 3/5 Rule Illustration 4
Hydraulic Hoistway Section View 6
Machine Roomless Hoistway Section View 6
Dimensions for Standard Configurations 7
Minimum Rail Reactions 8
Elevator Electrical Requirements 8
If the Controller is to be Located Outside of the Hoistway 8
Optional Hydraulic Equipment Machine Room 8
Hoistway/Pit Construction Detail 11
Construction Requirements for Guide Rail Structural Support & Structural Support Assembly 12
Specifications: Division 14205 Residential Elevator (MRL) Machine Roomless 13
Specifications: Division 14205 Residential Elevator (Hydro) Hydraulic Drive 16
Hoistway Rail Backing Requirements 20
Request for Quote/Drawings/Order Form 21
Home Elevator Pricing 22
Why Advantage 23
What Should You Consider When Choosing A Home Elevator Dealer? 24
TABLE OF CONTENTS
Planning Guide
4
Questions? 858.678.8780 Design Information Guide
Page 6 - Advantage Home Elevator - Design Information Guide (Revision 08-08-11) Copyright © 2011 EECO
Common Advantage Home Elevator Hoistway Configurations
Rail Tower Left Rail Tower Right Rail Tower Opposite
Hoistway Configuration Rail Tower Door Strike
Inline = I
Left = L Left = L
Right = R Right = R
Opposite = O
90o = 9 Left = L Left = L
Right = R Right = R
Pass-Through = P Left = L Left = L
Right = R Right = R
Choose an option from each column to determine your Model Configuration
(i.e. - Inline, Left, Right = ILR)
90o Rail Tower Left 90o Rail Tower Right Pass Through
Rail Tower Left/Right
Inline Configurations
90o Configurations Pass Through Configuration
Note: Front and Rear openings must be chosen at order entry. Recommendation - Front should be the side with maximum traffic/use.
The Car Operation Panel (COP) will always be located on the front opening side of rail center and on the guide tower side of the cab.
Common elevator interior is wood veneer on plywood. Custom wood interiors are optional.
Stainless steel glass or aluminum cars are available.
Standard is a bi fold vinyl gate. Metal or Plexiglas gates are an option.
Controls are stainless steel or brass. Antique bronze is an option.
Standard cab height is 84”. 96” is available
Standard cab dimension is 36” x 48”. 36” x 60” and 40” x 54” are available.
Extra Large cabs require 1400 lb. slings.
Hands-free phone on COP is included.
Planning Guide
5
Questions? 858.678.8780
Design Information Guide
Page 4 - Advantage Home Elevator - Design Information Guide (Revision 08-08-11) Copyright © 2011 EECO
Hoistway/Pit Construction Detail Door 3/5 Rule Illustration
ARCHITECTS SAMPLE OVERHEAD DRAWING
Architect’s PDF and CAD Drawings homeelevatorsandiegocounty.com
Robert Ingram [email protected]
Phone: 858.678.8780 Fax: 442.244.0014
7017 Ivy Street Carlsbad, CA 92011
Planning Guide
6
Questions? 858.678.8780
Design Information Guide
(Revision 08-08-11) Design Information Guide - Advantage Home Elevator - Page 5 Copyright © 2011 EECO
Hydraulic Section View:
Machine Roomless Section View:
FOR LOW OVERHEAD SITUATION REQUIRE 24” MINIMUM OVER CAB
Planning Guide
7
Questions? 858.678.8780
Page 4
Note: All dimensions are to inside finished walls.
The tables on pages 4 - 6 illustrate standard pocket gates that allow a larger clear opening in the doorway. The tables on pages 7 and 8 illustrate the three standard car sizes with optional non-pocketed gates. Custom sizes are available in �" increments from 36" to 4�" width by 48" to 60" depth (1� ft� minimum, 15 ft� maximum). Consult ThyssenKrupp Access for hoistway details.
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 54" 55" �81/�" �81/�" 3�1/8"
36 x 60 54" 67" 3�7/8" �81/�" 3�1/8"
40 x 54 58" 61" 301/8" �81/�" 357/8"
Type 1 - Left Hand Car with Standard Pocket GateGate Stack - Opposite Rail
Depth
Centerof Rail
Centerof Door
Width Width
Depth
Centerof Rail
Centerof Door
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 54" 55" �61/�" �81/�" 3�1/8"
36 x 60 54" 67" 33" �81/�" 3�1/8"
40 x 54 58" 61" 30" �81/�" 357/8"
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 501/�" 55" �81/�" �81/�" 3�1/8"
36 x 60 501/�" 67" 3�7/8" �81/�" 3�1/8"
40 x 54 541/�" 61" 301/8" 3�3/4" 357/8"
Depth
Centerof Rail
Centerof Door
Width
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 501/�" 55" �61/�" �81/�" 3�1/8"
36 x 60 501/�" 67" 33" �81/�" 3�1/8"
40 x 54 541/�" 61" 30" 3�3/4" 357/8"
Type 1 - Right Hand Car with Standard Pocket GateGate Stack - Opposite Rail
Type 1 - Left Hand Car with Standard Pocket GateGate Stack - Rail Side
Type 1 - Right Hand Car with Standard Pocket GateGate Stack - Rail Side
Note: All dimensions are to inside finished walls.
Width
Depth
Centerof Rail
Centerof Door
Type 1Right Hand
Type 1Left Hand
Type 1Right Hand
Type 1Left Hand
Planning Guide
8
Questions? 858.678.8780
Page 5
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 54" 551/�" �91/4" �81/�" 3�1/8"
36 x 60 54" 671/�" 333/4" �81/�" 3�1/8"
40 x 54 58" 611/�" 303/4" �81/�" 357/8"
Centerof Rail
Centerof Door
Depth
Width
Centerof Rail
Centerof Door
Depth
Width
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 501/�" 551/�" �91/4" �81/�" 3�1/8"
36 x 60 501/�" 671/�" 333/4" �81/�" 3�1/8"
40 x 54 541/�" 611/�" 303/4" 3�3/4" 357/8"
Type 2 - Straight-thru Car with Standard Pocket GatesGate Stack - Opposite Rail
Type 2 - Straight-thru Car with Standard Pocket GatesGate Stack - Rail Side
Type 2
Type 2
Note: All dimensions are to inside finished walls.
Note: All dimensions are to inside finished walls. All hoistway sizes shown are for use with standard electromechanical interlocks. Hoistway sizes change when using optional G.A.L. interlocks. For G.A.L. dimensions and more detailed information of all hoistway sizes, go to: www.tkaccess.com/levhoistway
Planning Guide
9
Questions? 858.678.8780
Page 6
Type 3 - Car with Standard Pocket GatePocket gate only available with gate stack on rail side.
Type 4 - Car with Standard Pocket GatePocket gate only available with gate stack on rail side.
Depth
Centerof Rail
Centerof Door 1
Width
Centerof Door �
DepthCenterof Rail
Centerof Door 1
Width
Centerof Door �
† Dimension when car gate is mounted opposite side from what is shown.
Note: All dimensions are to inside finished walls.
† Dimension when car gate is mounted opposite side from what is shown.
Type 3
Type 4
Center Center Center Clearance Clearance Car Size Width Depth of Rail of Door 1 of Door 2 of Door 1 of Door 2
36 x 48 5�1/8" 55" �61/�" �81/�" 331/�" 3�1/8" �85/8" 331/4"†
36 x 60 5�1/8" 67" 33" �81/�" 451/�" 3�1/8" 3�1/8" 413/4"†
40 x 54 561/8" 61" 301/8" 3�3/4" 391/�" 351/8" 3�1/8" 351/4"†
Center Center Center Clearance Clearance Car Size Width Depth of Rail of Door 1 of Door 2 of Door 1 of Door 2
36 x 48 5�1/8" 55" �81/�" �81/�" 331/�" 3�1/8" �85/8" 331/4"†
36 x 60 5�1/8" 67" 3�7/8" �81/�" 451/�" 3�1/8" 3�1/8" 413/4"†
40 x 54 561/8" 61" 301/8" 3�3/4" 391/�" 351/8" 3�1/8" 351/4"†
Note: All dimensions are to inside finished walls. All hoistway sizes shown are for use with standard electromechanical interlocks. Hoistway sizes change when using optional G.A.L. interlocks. For G.A.L. dimensions and more detailed information of all hoistway sizes, go to: www.tkaccess.com/levhoistway
Planning Guide
10
Questions? 858.678.8780
Page 7
Hoistway Construction: Type 1 Cars - Enter/Exit Same Side with Optional Non-Pocketed Gate
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 501/�" 55" �81/�" �81/�" �85/8"
36 x 60 501/�" 67" 3�7/8" �81/�" �85/8"
40 x 54 541/�" 61" 301/8" �81/4" 3�1/8" 3�3/4"†
Hoistway Construction: Type 2 Car - Straight-Thru with Optional Non-Pocketed Gates
Centerof Rail
Centerof Door
Depth
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 501/�" 551/�" �91/4" �81/�" �85/8"
36 x 60 501/�" 671/�" 333/4" �81/�" �85/8"
40 x 54 541/�" 611/�" 303/4" �81/4" 3�1/8" 3�3/4"†
Type 1Right Hand
Type 1Left Hand
Depth
Centerof Rail
Centerof Door
Width Width
Depth
Centerof Rail
Centerof Door
Width
† Dimension when car gate is mounted opposite side from what is shown.
Type 2
† Dimension when car gate is mounted opposite side from what is shown.
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 501/�" 55" �61/�" �81/�" �85/8"
36 x 60 501/�" 67" 33" �81/�" �85/8"
40 x 54 541/�" 61" 30" �81/4" 3�1/8" 3�3/4"†
Note: All dimensions are to inside finished walls. All hoistway sizes shown are for use with standard electromechanical interlocks. Hoistway sizes change when using optional G.A.L. interlocks. For G.A.L. dimensions and more detailed information of all hoistway sizes, go to: www.tkaccess.com/levhoistway
Planning Guide
11
Questions? 858.678.8780
Page 8
Hoistway Construction: Type 5 Cars - Enter/Exit Adjacent Side with Optional Non-Pocketed Gate
Center Center Center Door 1 Door 2 Car Size Width Depth of Rail of Dr 1 of Dr 2 Opening Opening
36 x 48 5�1/8" 55" �81/�" �81/�" 331/�" �85/8" �85/8" 331/4"†
36 x 60 5�1/8" 67" 3�7/8" �81/�" 451/�" �85/8" �85/8" 451/4"†
40 x 54 561/8" 61" 301/8" �81/4" 391/�" 3�1/8" 3�1/8" 3�3/4"† 351/4"†
DepthDepth
Type 3 Type 4
Centerof Rail
Centerof Rail
Centerof Door 1
Centerof Door 1
Width Width
Centerof Door �
Centerof Door �
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 5�1/8" 55" �51/�" 331/�" 3�1/8" �91/�"†
36 x 60 5�1/8" 67" 33" 451/�" 3�1/8" 417/8"†
40 x 54 561/8" 61" 301/8" 391/�" 3�1/8" 351/4"†
DepthDepth
Type 5Left Hand
Type 5Right Hand
Centerof RailCenter
of Rail
Width Width
Centerof Door
Centerof Door
† Dimension when car gate is mounted opposite side from what is shown.
† Dimension when car gate is mounted opposite side from what is shown.
Center Center Center Door 1 Door 2 Car Size Width Depth of Rail of Door 1 of Door 2 Opening Opening
36 x 48 5�1/8" 55" �61/�" �81/�" 331/�" �9" �85/8" 331/4"†
36 x 60 5�1/8" 67" 33" �81/�" 451/�" �9" �85/8" 451/4"†
40 x 54 561/8" 61" 301/8" �81/4" 391/�" 3�" 3�1/8" 3�3/4"† 351/4"†
Center Center Clear Car Size Width Depth of Rail of Door Opening
36 x 48 5�1/8" 55" �81/�" 331/�" 3�1/8" �93/4"†
36 x 60 5�1/8" 67" 3�7/8" 451/�" 3�1/8" 417/8"†
40 x 54 561/8" 61" 301/8" 391/�" 3�1/8" 351/4"†
Hoistway Construction: Type 3 & 4 Cars - Enter/Exit 90° Side with Optional Non-Pocketed Gates
Note: All dimensions are to inside finished walls.
Planning Guide
12
Questions? 858.678.8780
Design Information Guide
Page 8 - Advantage Home Elevator - Design Information Guide (Revision 08-08-11) Copyright © 2011 EECO
Construction Requirements for Guide Rail Structural Support:
Use a 4" x 12" board or create an assembly of two 2" x 4" boards and two 2" x 12" boards using wood glue and #10 x 2 1/2" wood screws to create a structural support of appropriate strength (as shown below).
Secure the above guide rail support at the top and bottom of the hoistway as well as at nine foot increments (or less) down the length of the hoistway.
Structural Support Assembly:
Minimum Rail Reactions:
RX = 215 foot pounds RY = 550 foot pounds
Safety considerations are not included in above rail reactions. When designing the hoistway you must include appropriate safety conditions. The force to pull out each fastener should not be less than 150 lbs.
See Page 16 for more details about
Hoistway Rail Backing Requirements
Elevator Electrical Requirements:
BY OTHERS: Arrange for supply power at top of hoistway prior to installation.
a: 230V, 1 phase, 30 amp, 60 Hz for main power supply: The main line supply shall consist of L1 (hot), L2 (hot). Dedicated neutral and ground installed through a lockable fused disconnect with an interlock auxiliary contact kit for battery lowering. 10-3 wire shall be used.
b: 110V, 15 amp, 60 Hz dedicated service for cab lighting; the car light supply shall consist of hot, neutral and ground installed through a lockable fused disconnect or circuit breaker
All fusing and electrical hook up to supply should be done to local code.
BY OTHERS: The overhead machine space requires a 110V, 15 amp, 60 Hz branch circuit for no less than 10 candle power of lighting. Providing a lighting fixture with light guard and an on/off switch to control the light located in such a way that personal entry into the machine space is not required to activate the switch.
BY OTHERS: Telephone line brought into the controller. A two-position 3.5mm plug is provided on the controller interface board for the incoming telephone line.
If the Controller is to be Located Outside of the Hoistway:
The Advantage Home Elevator controller cabinet is 21" wide by 15 1/2" high by 8" deep. When attached to a wall outside of the hoistway, you must leave a 36" square work area in front of the controller cabinet.
The controller must be located no more than 50 feet from the drive motor.
Optional Hydraulic Equipment Machine Room:
Planning Guide
13
Questions? 858.678.8780
Design Information Guide
(Revision 08-08-11) Design Information Guide - Advantage Home Elevator - Page 9 Copyright © 2011 EECO
Division 14205
Advantage Home Elevator Residential Machine Roomless (MRL)
Part 1 GENERAL
1.01 SECTION INCLUDES
A. Residential elevator with variable frequency speed control geared machine with counter weight chain drive.
1.02 WORK INCLUDED
A. Furnish all labor, materials and equipment necessary to assemble and install a residential elevator complete with rail sections, drive motor, controller, weight frame, weights, sling, tape landing system, plug & play wiring and controls required for proper operation, platform and cab.
1.03 WORK BY OTHERS
A. Hoistway: 1. Construct a hoistway of the proper size for
the car size specified complete with structure and reinforcements necessary to support the elevator.
2. Hoistway size: See manufacturer's drawings for size required for the cab size specified.
3. Hoistway shall be plumb vertically with maximum deviation of 1/4” in 20 feet.
4. Attach vertical members in hoistway per manufacturer's recommendations to a load bearing wall that is able to handle the
stress of the rail loads. 5. Pit Construction: Pit depth is 8" preferred, minimum is 6", below finished floor level of
the lowest landing. The pit floor must be of sufficient strength as to withstand a minimum 3400 pound impact.
6. Provide a lockable service door of adequate size (18" x 24" minimum) for access to hoistway drive equipment.
B. Electrical: 1. Provide a dedicated line, 230V, 1 phase, 60 Hz, for main power supply; The main line supply shall consist of L1 (hot), L2 (hot), dedicated neutral and ground installed through a lockable fused disconnect with an interlock auxiliary contact kit. 2. Provide a dedicated line, 110V, 1 phase, 60 HZ, for cab lighting; The car light supply shall consist of hot, neutral and ground installed through a lockable fused disconnect or circuit breaker.
3. Provide telephone line to controller. 4. Provide a system to maintain hoistway
temperature between 50 and 90 degrees Fahrenheit.
1.04 REFERENCES
A. American Society of Mechanical Engineers (ASME) publication: ASME A.17.1/CSA-B44 "Safety Codes for Elevators and Escalators", Section 5.3.
B. National Fire Protection Association (NFPA) publication: NFPA 70 National Electrical Code.
1.05 PROJECT REQUIREMENTS
A. Total travel: (50'-0" max.) lowest level to top level.
B. Stops: (4 max.) C. Load Capacity: (950 Lbs./750 Lbs.) D. Speed: (40 Feet per minute nominal) E. Pit Depth: (6" min,; 8" preferred) F. Overhead: (9'-2" min. based on 7'-0” cab height)
1.06 SUBMITTALS
A. Shall be in accordance with Section 01300 submittals.
B. Shall include manufacturer's product data and requirements.
C. Shop drawings showing: 1. Field requirements 2. Hoistway dimensions 3. Cab elevations and cab and gate finishes 4. Fixture Elevations and finishes
1.07 QUALITY ASSURANCE
A. Qualifications: 1. Manufacturer's Qualifications: Company
whose primary business is the manufacturing of residential and commercial elevator systems and components. Company shall have a written quality assurance program in affect.
2. Installer Qualifications: Installer must be approved by manufacturer and be experienced in assembly and erection of residential elevators. Installer must be trained for the specific equipment being installed.
B. Regulatory Requirements: The manufacture and installation shall be in accordance with all Federal, State and Local Codes and Ordinances. The installer shall be responsible for verifying and complying with the
Planning Guide
14
Questions? 858.678.8780
Design Information Guide
Page 10 - Advantage Home Elevator - Design Information Guide (Revision 08-08-11) Copyright © 2011 EECO
requirements of the local authority having
jurisdiction and all local codes.
1.08 DELIVERY, HANDLING AND STORAGE
A. All material shall be packaged to protect from damage during shipping and handling. Material shall be immediately inspected upon delivery. Material shall be kept in a clean and dry environment until installed. Cab panels shall be stored to prevent warping or bowing.
1.09 WARRANTY
A. Elevator shall be provided with a 2 year limited manufacturers parts warranty.
1.10 MAINTENANCE
A. Maintenance of elevator and components shall be done by a qualified elevator technician. Service shall not exceed 12 month intervals.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Manufacturer: Elevator shall be Model "MRL" as provided by Advantage Home Elevator, division of Elevator Equipment Corporation.
B. Substitutions: No substitutions shall be considered unless written request outlining all features have been submitted and approved by Architect at least 10 days prior to bid date.
2.02 COMPONENTS
A. Modular Rail System: Consisting of two 6 1/4 lb. tee rails factory welded to 11 gauge channels complete with steel mounting plates, splice plates, shims and zinc plated hardware. Modular rail system shall be in maximum 10 foot sections and shall act as counterweight guide system.
B. Drive and Controller system: 1. U.L. Listed, field programmable micro-
processor with a variable frequency speed drive controller with onboard diagnostic, fault log, run counter, and automatic floor homing. Controller shall send fault flash codes to the hall stations to diagnose operational faults.
2. Geared machine with counterweight chain drive.
3. 3 H.P. motor with electromechanical brake and manual release.
4. Uninterruptible power supply (UPS) for lowering in case of power failure. UPS shall also power an emergency light in the cab and power an emergency alarm. The
UPS shall have an automatic recharging
system. 5. Provide tape selector landing system with
3" wide steel tape and magnets. Selector box shall be accessible from behind the car operating panel.
6. Provide two upper and one lower final limits.
7. Motor, controller and landing system shall be factory tested prior to shipment.
C. Sling and Platform: 1. Shall be designed to carry car and
specified capacity. 2. Sling shall be factory painted. 3. Sling shall be provided with a slack chain
safety device to mechanically activate and stop the downward travel due to a slack chain. This safety is also equipped with a switch, when activated, interrupts the drive circuit of the controller.
4. Sling shall be provided with four UHV guide shoes.
5. Provide a platform toe guard at each cab entrance.
6. Platform shall have a removable subfloor that will accept a 1/4" to 3/4" finish floor. Finish floor by others.
D. Wiring: 1. Provide traveling cable for electrical lights,
telephone and controls in car. 2. Provide Cat-5 "Plug & Play" connection
wiring from controller to hall stations and interlocks. All wiring shall be insulated, flame retardant, and moisture proof copper wiring installed in flexible aluminum conduit.
E. Hoistway Door: 1. 3'-0" wide x 6'-8" high minimum 2. Elevator Contractor or Owner shall
provide and install hoistway doors, frames and hardware. The type and installation of frames shall comply with ASME A.17.1/CSA-B44, all state and local codes and per manufacturer's approved shop drawings.
3. Hoistway doors shall have U.L. Listed electro- mechanical door interlocks which locks hoistway door when cab is not present and interrupts electrical power when door is not closed. The door shall remain locked when the cab is not in the landing zone.
F. Cab: 1. Nominal inside dimensions shall be
(choose one) 36" x 48"; 40" x 54"; 36" x 60"; or up to 15 sq. ft. and shall
Planning Guide
15
Questions? 858.678.8780
Design Information Guide
(Revision 08-08-11) Design Information Guide - Advantage Home Elevator - Page 11 Copyright © 2011 EECO
be high. (80" thru 96") 84" Std. 2. Cab enclosure shall be securely attached
to sling and platform. The walls and ceiling shall be minimum 3/4" thick. The platform shall be made of 1" thick AC plywood. Style and finish shall be as marked below:
Walls and Ceiling: Unfinished hardwood veneer panels: Birch (std) Oak (std) Maple (std) Cherry (opt) Mahogany (opt) Alder (opt) Hickory (opt) Walnut (opt) Optional unfinished recessed wall panels:
(choose veneers above) Optional unfinished raised wall panels:
(choose veneers above) Optional flat laminate wall panels: Antique White Black Desert Glow White First Light Natural Oak Brunette Pinstripe Harvest Cherry Autumn Glow English Oak Optional Thermofoil inset designer paneling: Kasei Maple Sakura Cherry Mahogany Sienna Wild Apple 3. Gate shall be accordion type with a normally opened mechanical switch to indicate that the
gate is closed. Type and color shall be as marked below:
Car gate type: Accordion solid panels (std) Accordion gate with 2 clear panels Accordion gate with all clear panels Car gate color: Antique White (std) White (std) Black (std) Cherry (std) Light Oak (std) Walnut (std) Birch (std) Chalk (std) Dark Oak (std) Mahogany (std) Automatic gate operator (opt): Qty: Automatic door operator (opt): Qty: 4. Handrail: Provide one mounted on cab wall. Handrail shall be a 1 1/2" diameter metal with
return to wall ends or a straight 1/2” x 3" wood to match cab finish.
5. Telephone: Provide one recessed phone box. 6. Car Operating Panel (COP): Provide one
momentary pressure dual LED illlllluminated button for each landing, emergency stop switch, alarm button and car light switch.
7. Hall Stations: At each hoistway door, provide one hall station with dual LED and
“Car Here” light. 8. Fixture Finishes: Finish for COP, hall station, metal handrail and phone box if
specified shall be: (choose one) Brushed Stainless Steel (std) Brushed Brass (std) Oil Rubbed Brass (opt) Mirror Stainless Steel (opt) Mirror Brass (opt) Flat Fixtures (opt) 9. Cab Lighting: Provide two recessed MR-16
halogen overhead light fixtures with satin trim rings. Lights shall turn on automatically when car is in use and turn off with a timer circuit.
2.02 ACCESSORIES (optional)
A. Pocketed gates. B. Car and/or hall station key switch. C. Automatic car gate operator and with kinetic
energy break-away device and COP Door Open Button.
D. Automatic hoistway door operators. Consult factory for items not listed.
PART 3 EXECUTION
3.01 INSTALLATION
A. Inspect the hoistway and determine if the hoistway meets the manufacturer's requirements for clearances and plumbness.
B. All components shall be assembled and erected in strict compliance with manufacturer's printed instructions and applicable codes.
C. All wiring shall be in accordance with the wiring diagram furnished by the manufacturer, NEG, and local electrical codes.
3.02 FIELD QUALITY CONTROL
A. Static/Running Load Test: All load rating and safety factors shall meet or exceed those specified in ASME A17.1/CSA-B44.
3.03 ADJUSTING
A. Elevator Contractor shall test the elevator to assure proper operation under all conditions of use. Make proper adjustments and review operating components for proper operation.
3.04 OWNER INSTRUCTIONS
A. Elevator Contractor shall provide the owner or owner's representative with proper operation instructions prior to releasing elevator for use.
FOR FURTHER INFORMATION AND DETAILS, PLEASE CONTACT ADVANTAGE HOME
ELEVATOR 888.877.4762 OR CONTACT US THRU:
WWW.ADVANTAGEELEVATOR.NET
Planning Guide
16
Questions? 858.678.8780Design Information
Guide
Page 12 - Advantage Home Elevator - Design Information Guide (Revision 08-08-11) Copyright © 2011 EECO
Division 14205
Advantage Home Elevator Residential Elevator (HYDRO) Hydraulic Drive
Part 1 GENERAL
1.01 SECTION INCLUDES
A. Residential elevator with 1:2 hydraulic chain driven system.
1.02 WORK INCLUDED
A. Furnish all labor, materials and equipment necessary to assemble and install a residential elevator complete with rail sections, controller with hydraulic jack, submersible power unit, sling, tape landing system, plug & play wiring and controls required for proper operation, platform and cab.
1.03 WORK BY OTHERS
A. Hoistway: 1. Construct a hoistway of the proper size for
the car size specified complete with structure and reinforcements necessary to support the elevator.
2. Hoistway size: See manufacturer's drawings for size required for the cab size specified.
3. Hoistway shall be plumb vertically with maximum deviation of 1/4" in 20 feet.
4. Attach vertical members in hoistway per manufacturer's recommendations to a load bearing wall that is able to handle the stress of the rail loads.
5. Pit Construction: Pit depth is 12" preferred, 8" min., below finished floor level of the lowest landing. The pit floor must be of sufficient strength as to withstand a minimum 3400 pound impact.
6. The machine room requires a 110V, 15 amp, 60 Hz branch circuit for machine room light with no less than 10 candle power, and a GFIC duplex receptacle. Provide a lighting fixture with a light guard and on/off switch to control the light.
7. Provide a system to maintain machine room/space temperature between 50 and 90 degrees Fahrenheit.
8. Machine room/space shall be enclosed with a self closing and self-locking door.
9. SAE 32 turbine oil or bio-degradable oil and hydraulic feed line and fittings from the ball valve to the pump unit that conforms to ASME A17.1/CSA B-44.
B. Electrical:
1. Provide a dedicated line to the machine room/space, 230V, 1 phase, 60 Hz, for main power supply; The main line supply shall consist of L1 (hot), L2 (hot), dedicated neutral and ground installed through a lockable fused disconnect with an interlock auxiliary contact kit.
2. Provide a dedicated line to machine/space, 110V, 1 phase, 60 HZ, for cab lighting; The car light supply shall consist of hot, neutral and ground installed through a lockable fused disconnect or circuit breaker.
3. Provide telephone line to controller.
1.04 REFERENCES
A. American Society of Mechanical Engineers (ASME) publication: ASME A.17.1ICSA-B44 "Safety Codes for Elevators and Escalators", Section 5.3.
B. National Fire Protection Association (NFPA) publication: NFPA 70 National Electrical
Code.
1.05 PROJECT REQUIREMENTS
A. Total travel: (40'-0" max.) lowest level to top level.
B. Stops: (4 max.) C. Load Capacity: (950 Lbs./750 Lbs.) D. Speed: (40 Feet per minute nominal) E. Pit Depth: (8" min.; 12" preferred) F. Overhead: (8'-3" min. based on 7'-0”
cab height)
1.06 SUBMITTALS:
A. Shall be in accordance with Section 01300 submittals.
B. Shall include manufacturer's product data and requirements.
C. Shop drawings showing: 1. Field requirements 2. Hoistway dimensions 3. Cab elevations and cab and gate finishes 4. Fixture Elevations and finishes 5. Manufacturer shall provide suggested
machine room space requirements.
1.07 QUALITY ASSURANCE
A. Qualifications: 1. Manufacturer's Qualifications: Company
whose primary business is the manufacturing of residential and commercial elevator systems and
Planning Guide
17
Questions? 858.678.8780
Design Information Guide
(Revision 08-08-11) Design Information Guide - Advantage Home Elevator - Page 13 Copyright © 2011 EECO
components. Company shall have a
written quality assurance program in affect.
2. Installer Qualifications: Installer must be approved by manufacturer and be experienced in assembly and erection of residential elevators. Installer must be trained for the specific equipment being installed.
B. Regulatory Requirements: The manufacture and installation shall be in accordance with all Federal, State and local Codes and Ordinances. The installer shall be responsible for verifying and complying with the requirements of the local authority having Jurisdiction and all local codes.
1.08 DELIVERY, HANDLING AND STORAGE
A. All material shall be packaged to protect from damage during shipping and handling. Material shall be immediately inspected upon delivery. Material shall be kept in a clean and dry environment until installed. Cab panels shall be stored to prevent warping or bowing.
1.09 WARRANTY
A. Elevator shall be provided with a 2 year limited manufacturers parts warranty.
1.10 MAINTENANCE
A. Maintenance of elevator and components shall be done by a qualified elevator technician. Service shall not exceed 12 month intervals.
PART 2 PRODUCTS
2.01 MANUFACTURERS
A. Manufacturer: Elevator shall be Model "HYDRO" as provided by Advantage Home Elevator, division of Elevator Equipment Corporation.
B. Substitutions: No substitutions shall be considered unless written request outlining all features have been submitted and approved by Architect at least 10 days prior to bid date.
2.02 COMPONENTS
A. Modular Rail System: Consisting of two 6 1/4 lb. tee rails factory welded to 11 gauge channels complete with steel mounting plates, splice plates, shims and zinc plated hardware. Modular rail system shall be in maximum 10 foot sections and shall act as counter weight guide system.
B. Controller system:
1. U.L. Listed, field programmable microprocessor controller with onboard diagnostic, fault log, run counter, and automatic floor homing. Controller shall
send fault flash codes to the hall stations to diagnose operational faults.
2. Uninterruptible power supply (UPS) for lowering in case of power failure. UPS shall also power an emergency light in the cab and power an emergency alarm. The UPS shall have an automatic recharging system.
3. Provide tape selector landing system with 3" wide steel tape and magnets. Selector box shall be accessible from behind the car operating panel.
4. Provide two upper and one lower final limits.
5. Controller with power unit and landing system shall be factory tested prior to shipment.
C. Hydraulic power unit: 1. The submersible pump, motor and control
valve shall be factory prewired to the controller.
2. Submersible motor shall be 3 H.P. 208 or 230V, 1 phase, 60 Hz.
3. Control valve shall have adjustable up acceleration, leveling and stop.
4. Control valve shall have adjustable down acceleration, main speed, leveling and stop.
5. Control valve shall have manual lowering and low pressure switch.
6. Fill/dipstick provision. D. Hydraulic single stage jack unit:
1. Cylinder shall be steel pipe with a head guide bearing and a pressure balance "U" style packing.
2. Piston shall be 3" OD steel tubing DOM grade 1026 material ground and polished to a surface finish 16-20 micro inches. Diameter shall be +/- .015" tolerance.
3. Piston shall have a factory welded stop ring to prevent piston from leaving cylinder.
4. Jack shall be provided with a adjustable pipe rupture safety valve
5. Jack shall be provided with a ball shut off valve.
6. Yoke assembly shall be mounted to top of piston and include sheaves to obtain 1:2 chain drive system.
Planning Guide
18
Questions? 858.678.8780
Design Information Guide
Page 14 - Advantage Home Elevator - Design Information Guide (Revision 08-08-11) Copyright © 2011 EECO
E. Sling and Platform:
1. Shall be designed to carry car and specified capacity.
2. Sling shall be factory painted. 3. Sling shall be provided with a slack chain
safety device to mechanically activate and stop the downward travel due to a slack chain. This safety is also equipped with a switch, when activated, interrupts the drive circuit of the controller.
4. Sling shall be provided with four UHV guide shoes.
5. Provide a platform toe guard at each cab entrance.
6. Platform shall have a removable subfloor that will accept a 1/4 to 3/4" finish floor. Finish floor by others.
F. Wiring: 1. Provide traveling cable for electrical lights,
telephone and controls in car. 2. Provide Cat-5 "Plug & Play" connection
wiring from controller to hall stations and interlocks. All wiring shall be insulated, flame retardant, and moisture proof copper wiring installed in flexible aluminum conduit.
G. Hoistway Door: 1. 3'-0" wide x 6'-8" high minimum 2. Elevator Contractor or Owner shall
provide and install hoistway doors, frames and hardware. The type and installation of frames shall comply with ASME A.17.1/CSA-B44, all state and local codes and per manufacturer's approved shop drawings.
3. Hoistway doors shall have U.L. Listed electro mechanical door interlocks which locks hoistway door when cab is not present and interrupts electrical power when door is not closed. The door shall remain locked when the cab is not in the landing zone.
H. Cab: 1. Nominal inside dimensions shall be
(choose one) 36" x 48"; 40" x 54"; 36" x 60"; or up to 15 sq. ft. and shall
be high. (80" thru 96") 84" standard. 2. Cab enclosure shall be securely attached
to sling and platform. The walls and ceiling shall be minimum 3/4"thick. The platform shall be made of 1" thick AC plywood. Style and finish shall be as marked below:
Walls and Ceiling: Unfinished hardwood veneer panels: Birch (std) Oak (std)
Maple (std) Cherry (opt) Mahogany (opt) Alder (opt) Hickory (opt) Walnut (opt) Optional unfinished recessed wall panels:
(choose from veneers above) Optional unfinished raised wall panels:
(choose from veneers above) Optional flat laminate wall panels: Antique White Black Desert Glow White First Light Natural Oak Brunette Pinstripe Harvest Cherry Autumn Glow English Oak Optional Thermofoil inset designer paneling: Kasei Maple Sakura Cherry Mahogany Sienna Wild Apple 3. Gate shall be accordion type with a normally opened mechanical switch to indicate that the
gate is closed. Type and color shall be as marked below:
Car gate type: Accordion solid panels (std) Accordion gate with 2 clear panels Accordion gate with all clear panels Car gate color: Antique White (std) White (std) Black (std) Cherry (std) Light Oak (std) Walnut (std) Birch (std) Chalk (std) Dark Oak (std) Mahogany (std) Automatic gate operator (opt): Qty: Automatic door operator (opt): Qty: 4. Handrail: Provide one mounted on cab wall. Handrail shall be a 1 1/2" diameter metal with
return to wall ends or a straight 1/2” x 3" wood to match cab finish.
5. Telephone: Provide one recessed phone box. 6. Car Operating Panel (COP): Provide one
momentary pressure dual LED illlllluminated button for each landing, emergency stop switch, alarm button and car light switch.
7. Hall Stations: At each hoistway door, provide one hall station with dual LED and
“Car Here” light. 8. Fixture Finishes: Finish for COP, hall station,
metal handrail and phone box shall be: (choose one)
Brushed Stainless Steel (std) Brushed Brass (std) Oil Rubbed Brass (opt) Mirror Stainless Steel (opt) Mirror Brass (opt) Flat Fixtures (opt)
Planning Guide
19
Questions? 858.678.8780Design Information Guide
(Revision 08-08-11) Design Information Guide - Advantage Home Elevator - Page 15 Copyright © 2011 EECO
9. Cab Lighting: Provide two recessed MR-16
halogen overhead light fixtures with satin trim rings. Lights shall turn on automatically when car is in use and turn off with a timer circuit.
2.02 ACCESSORIES (optional)
A. Pocketed gates. B. Car and/or hall station key switch. C. Automatic car gate operator and with kinetic
energy break-away device and COP Door Open Button.
D. Automatic hoistway door operators. Consult factory for items not listed.
PART 3 EXECUTION
3.01 INSTALLATION
A. Inspect the hoistway and determine if the hoistway meets the manufacturer's requirements for clearances and plumbness.
B. All components shall be assembled and erected in strict compliance with manufacturer's printed instructions and applicable codes.
C. All wiring shall be in accordance with the wiring diagram furnished by the manufacturer, NEG, and local electrical codes.
D. Hydraulic oil line and fittings shall be in accordance with ASME A17.1/CSA B-44 and local building codes.
3.02 FIELD QUALITY CONTROL
A. Static/Running Load Test: All load rating and safety factors shall meet or exceed those specified in ASME A17.1/CSA-B44.
3.03 ADJUSTING
A. Elevator Contractor shall test the elevator to assure proper operation under all conditions of use. Make proper adjustments and review operating components for proper operation.
3.04 OWNER INSTRUCTIONS
A. Elevator Contractor shall provide the owner or owner's representative with proper operation instructions prior to releasing elevator for use.
Planning Guide
20
Questions? 858.678.8780Design Information
Guide
Page 16 - Advantage Home Elevator - Design Information Guide (Revision 08-08-11) Copyright © 2011 EECO
Hoistway Rail Backing Requirements
Planning Guide
21
Questions? 858.678.8780
• A standard two-stop MRL home elevator is $24,000
• Extra stops add $2,000 each.
• Extra cab entrances (side or rear) add $2,000
• Extra large cabs add $3,000
• Hydraulic operation add $4,000
• Recessed panel walls add $3,000 to $6,000
• Stainless steel or aluminum cabs add $4,000 to $6,000
• Antique bronze controls add $1,000
• Glass cab walls add $3,000 each
• Automatic gate operators are $2,000 each
• Automatic swing door operators are $2,000 each
• Premium cab gate add $1,000 each
• Machine at base is $2,000
• Remote machine rooms $100 per foot for hydraulic elevators, $50 per foot for MRL modified
• Pit less elevators add $4,000
HOME ELEVATOR PRICINGAs at January 1, 2017 (Use as a guide only) Installed, freight and tax included.
Prices subject to change with economic conditions.
7017 Ivy Street • Carlsbad, CA 92011 • Main 858.678.8780 • Fax 442.244.0014 • CSLB C11 #1027832Advantage Elevator Inc.
Field Survey / Quotation Request / Order FormDate ____________ Date Required ____________ Ship Date Required ____________
Package: Complete Group One
Unit Type: MRL 2:1 Hydro Direct Acting
Capacity: 950 lbs. 750 lbs. Other ______
Speed: 40 fpm Other ______
Power Supply: ______ Volts AC ______ Phase ______ Hertz
As viewed from lowest landing looking into hoistway
Configuration: In-Line Pass Thru 90o
Rail Location: Left Opposite Right
Gate Strike: Primary Left Right
Rear/Side Left Right
Door Strike: Right @ Floor 1 2 3 4 5 6
Left @ Floor 1 2 3 4 5 6
Door Locks: ESL Electro Mechanical
Project Information
Height: = _______
Width: MW = _______
Depth: MD = _______
Opening: MO = _______
Machine Room
Overhead: OH = ______
Total Floor Travel: T = ______
Pit Depth: PD = ______
Cab Height: CH = ______
Max. Allowable Cab Height
Entrance Height: EH = ______
No. of Landings: _______
Hoistway Section View
Hoistway Plan View Entrance Width: EW = ______
Wall Thickness: WT = ______
Wall Construction: Drywall Masonary Other ____________
Car Entrance Style: Accordion 2 Speed 3 Speed
Hall Entrance Style: Swing 2 Speed 3 Speed
Location: Adjacent Remote
Location = ___________________
Distance = ___________________
Travel to Floor
6: ______
5: ______
4: ______
3: ______
2: ______
Front Rear/Side
Project Name ___________________________________________________
Address ___________________________________________________
City __________________________ .St. ______ Zip __________
Company ___________________________________________________
Address ___________________________________________________
City __________________________ .St. ______ Zip __________
Customer Information
Provide data as complete as possible. Our ability to provide proper equipment depends upon the completeness and accuracy of the data that you furnish.
Contact ____________________________________________________
Phone __________________ Ext. ______ Fax __________________
Email ____________________________________________________
Special Requirements: _________________________________________
_______________________________________________________________
_______________________________________________________________
Ship to Address: Company Project Other
Other ___________________________________________________
Address ___________________________________________________
City __________________________ .St. ______ Zip __________
Request: Quote & Preliminary Drawings Order: PO Number __________
Minimum Short Floor 18”
7017 Ivy Street • Carlsbad, CA 92011 • Main 858.678.8780 • Fax 442.244.0014 • CSLB C11 #1027832Advantage Elevator Inc.
Field Survey / Quotation Request / Order Form
Cab Appointments
Gate / Entrances
#4 Stainless #4 Brass Black
Style: Touchstone (Flat) Diamond (Recessed) Elegance (Raised)
Unfinished Veneer: Birch Maple Red Oak Cherry Other _____________
Laminates: Touchstone Only White White Cypress Harvest Maple Tuscan Walnut English Oak Biltmore Cherry Empire Mahogany Other _________ (Wilsonart Selection)
Flooring: 1/4” Std. Other ______ Material _____________________
Lighting: 2 LED Std. 4 LEDs None
Handrail: Metal Std. Wood None Addtional ______ Qty.
Unfinished Cab Veneers
English Oak
Harvest Maple
Empire Mahogany
Biltmore Cherry
Tuscan Walnut
White Cypress
CherryBirch Red OakMaple
Cab Laminates
Laminate Gates
Fixture AppointmentsCOP Style: Hall Station Style: Raised Flat Raised Flat
Material: Stainless Steel Std. Brass Black Oil Rubbed
Finish: Brushed #4 Std. Mirrored #8 Other ______
Keyed Lockout Option: COP Hall Station @ Landing ______
SolidAluminum
PerforatedAluminum
SolidBrass
PerforatedBrass
SolidBronze
PerforatedBronze
BirchAntiqueWhite Chalk Maple
WalnutCherryLight Oak Mahogany
Metal Gates
Style: Laminate Std. Unfinished Veneer Perforated Metal Solid Metal with Acrylic Panels ______ Qty. Smoke Bronze All Acrylic with Metal Hinges
Laminates: White Antique Chalk Birch Maple Light Oak Cherry Dark Oak Walnut Mahogany
Veneers: Birch Maple Red Oak Cherry
Metal: Aluminum Brass Bronze
Operator: Gate ______ Qty. Swing Door ______ Qty.
Light Screen: with Gate
Slide Entrance Construction: #4 Stainless Steel Primed Custom ________ Contact EECO Home for details
Project Name ____________________________________
Dark Oak
White
Oil Rubbed
Fixture Finishes
Finished Veneer Gates
CherryMapleBirch Oak
PRINT CLEAR Email
Robert Ingram [email protected]
858.678.8780 Phone 442.244.0014 Fax
7017 Ivy Street Carlsbad, CA 92011
With many choices of residential elevators, only Advantage Home Elevator is backed by Elevator Equipment Corporation (EECO) a company with over 65 years of experience and pioneering innovation. EECO is a trusted name in the elevator industry, known for quality, safety, stability, and experience. With our years of expertise and dedication to excellence, Advantage Home Elevator will exceed all expectations for your home.
Unlike our competitors, Advantage Home Elevator makes the home elevator affordable by making luxury features standard. Most upgrade options are included in the base price of our unit. For those who desire a more unique look we offer choices ranging from Unfinished Veneers to Raised Thermofoil Panels*, and a selection of Brushed, Mirrored* or Oil Rubbed Brass* fixtures allowing you to make your Advantage Home Elevator as individual as you are. We also offer design consultations and unique features for those that desire a completely custom solution.
Architects, contractors, and home builders across the country prefer Advantage Home Elevator because of the ease of installation and superior customer support. Advantage Home Elevator prides itself on excellent customer service past the sale of our units to ensure a successful installation every time.
ADVANTAGE HOME ELEVATOR meets ASME/ANSI A17.1 Section 5.3 and has been designed by experienced industry professionals for safety, durability, aesthetic appeal and increased home value.
Whether you are building your dream home or already living in it, make Advantage Home Elevator part of your plans. For your convenience you can download AutoCAD files of our standard configurations from our website for inclusion into plan by your planner or architect.
• Two Year Warranty: Take every trip with confidence thanks to our manufacturer’s standard 2-Year Limited Parts Warranty.
• Smooth and Quiet: Our engineers have reduced residual friction noise with a special shaft design, unique gear set, variable frequency control system and beneficial dampeners and buffers throughout the unit.
• Multiple Drive Options: Choose from the Machine Roomless Design to save space or our Hydraulic Drive Design per your preference and local code requirements.
• Stylish and Modern: Our smooth stylish features are timeless and will blend with any decor for years to come. The fixtures feature LED push-buttons for that classic elevator feel right in your own home!
• Low Maintenance: The elevator was designed for little to no maintenance and the visual service alert and fault codes will tell you when it’s time to consider a service inspection.
• Emergency Lowering: In the event of power interruption, the elevator will engage the Battery Back-Up System to lower you to the next available floor below so that you may exit safely from the unit.
WHY ADVANTAGE