Home BUS Light

44
My Home light and motor automation: BUS system characteristics

description

MOTOR

Transcript of Home BUS Light

Page 1: Home BUS Light

My Home light and motor automation: BUS system characteristics

Page 2: Home BUS Light

System features

Page 3: Home BUS Light

3

WDS DIVISION

ApartmentVilla

Designed for residential application

My Home SCS bus system was designed with– System dimension and feature for homes– Designed to reduce the cabinet dimension– Installation method close to the traditional installation– Aesthetic integrated with WD

Page 4: Home BUS Light

4

WDS DIVISION

L

BUS system composition

Not one general central unit

No centralized configuration

Power supplyCommands

N

Actuators

Loads

27V BUS

Page 5: Home BUS Light

5

WDS DIVISION

SCS bus characteristics

Sender

Receiver

Information0 1 0 1 0 1 0 1 0 1 0 1

L230V

N

27V d.c. NOT POLARIZEDPower supply and digital data

Page 6: Home BUS Light

6

WDS DIVISION

Incandescent

Discharge

Halogen

Fluorescent

LED

Motors ON/OFF

Motors up/downright/left

Load typology driven: most of the typology

Page 7: Home BUS Light

7

WDS DIVISION

Wide catalogue range

User interfaces

Actuators

Dimmers

Interfaces

Accessories

Page 8: Home BUS Light

8

WDS DIVISION

Traditional configuration

To configure means: to give a logical

address and a working mode to each devices

Page 9: Home BUS Light

9

WDS DIVISION

Traditional configuration advantages

The configuration is visible at any time

No special tools/software for configuration

Not specialized competence for any maintenance

Page 10: Home BUS Light

10

WDS DIVISION

Virtual configuration

The Virtual Configuration is available to configure:– Automation devices– Thermo regulation devices– Energy management

LN

Page 11: Home BUS Light

11

WDS DIVISION

Virtual configuration advantage

Up-Down load system configuration

System configuration scan

Configurators and time saving

Easy re-configuration

You can clone the configuration!

Page 12: Home BUS Light

12

WDS DIVISION

Free BUS cabling topology

Star connections Free connection

Just one rule: no closed ring!

The choice is based on the installation need, function and wall limitation

Page 13: Home BUS Light

13

WDS DIVISION

Power supply Actuator Control

250m MAX 500m MAX

Physical possibilities: distance

For one power supply only! But you can expand it!

Page 14: Home BUS Light

15

WDS DIVISION

1.200mA available from the standard power supply

600mA from the compact power supply

Table of absorptions on the technical guide and YouProject calculates the total adsorption

Physical possibilities: absorption

LN

For one power supply only! But you can expand it!

Page 15: Home BUS Light

16

WDS DIVISION

Why one power supply only?

1 PS

2 PS

2 impedances in parallel cut the digital frames

Page 16: Home BUS Light

17

WDS DIVISION

9 Areas

9 PL for every area

9 x 9 = 81 address(Actuators, command has the same configuration)

Logical possibilities

Designed for the residential sector

For one power supply only! But you can expand it!

Page 17: Home BUS Light

18

WDS DIVISION

Lighting management integration

Some MH device are in common with LM system.

For this reason you can use the LM configuration rules and system limits.

Page 18: Home BUS Light

19

WDS DIVISION

Configuration

Page 19: Home BUS Light

20

WDS DIVISION

N

Sender (command)

Receiver (actuator)

Configuration concept

L

CLACK

CLICK

1. Define the address to identify sender-receiver link

2. Set the devices function modality

Page 20: Home BUS Light

21

WDS DIVISION

Configuration logics: area

Subdivide the plan in several Areas

Max 9 areas!

Each area has maximum 9 point of light

6

23

4

1

Page 21: Home BUS Light

22

WDS DIVISION

APL

APL1PL2PL3PL4

APL

Configuration logics: point of light

Max 9 lamp circuits

Subdivide the area in several Point of Light = PL

12

3

4L

N

Page 22: Home BUS Light

23

WDS DIVISION

APL1PL2PL3PL4

APL

Configuration logics: motor

Configure the motor actuator

PL1=PL2 to have interlocked relay

12

L

N

3

Page 23: Home BUS Light

24

WDS DIVISION

Point-to-point light configuration

A

PL

Command Actuator

A

PL

2

3

2

3

A=1PL1=1

A=1PL1=2

A=1PL1=3

A=1PL=2

A=1PL=3

A=1PL=1M=I/O

A=2PL1=1

A=2PL1=2

A=2PL1=3

A=2PL=2M=I/O

A=2PL=3

A=2PL=1

Commands to a single device (same A and same PL)

Page 24: Home BUS Light

25

WDS DIVISION

Point-to-point motor configuration

A=2PL1=1

PL2=1

A=2PL1=2

PL2=2

A=2PL1=3

PL2=3

A=2PL=1M=↑↓

A=2PL=2M=↑↓

A=2PL=3M=↑↓

A=1PL1=1

PL2=1

A=1PL1=2

PL2=2

A=1PL1=3

PL2=3

A=1PL=1M=↑↓

A=1PL=2M=↑↓

A=1PL=3M=↑↓

Motor as: shutter, curtain, sunbreaker

Commands to a single device (same A and same PL) with ↑↓ in M

A

PL

M

Command Actuator

A

PL

M

2

3

2

3

Page 25: Home BUS Light

26

WDS DIVISION

Ambient configuration

Command Actuator

A

PL1

PL2

2

22

AMB

Actuator

2

3A

PL

M 2 3

A=1PL1=1

A=1PL1=2

A=1PL1=3

A=1PL=2

A=1PL=3

A=1PL=1

A=2PL1=1

A=2PL1=2

PL2=2

A=2PL1=3

PL2=3

A=2PL=2

M=↑↓

A=2PL=3

M=↑↓

A=2PL=1

A=AMBPL=1

A=AMBPL=2M=↑↓

Command to every actuator with the same configurator A (AMB)

Page 26: Home BUS Light

27

WDS DIVISION

Group configuration

A=1PL=2

A=1PL=3

A=1PL=1

A=2PL1=2

PL2=2

A=2PL1=3

PL2=3

A=2PL=2

M=↑↓

A=2PL=3

M=↑↓

A=2PL=1

A=AMBPL=1

A=AMBPL=2M=↑↓

A=GRPL=1

A=GRPL=2

A=1PL1=1

A=1PL1=2

A=1PL1=3

A=2PL1=1

1

11

GR 1

2

1 1

Command to every actuator with the same site G (GR)Command Actuator Actuator

A

PL

GR

A

PL

Page 27: Home BUS Light

28

WDS DIVISION

General command

GEN

Command

A=GEN

PL=

A=1PL=2

A=1PL=3

A=1PL=1

A=2PL1=2

PL2=2

A=2PL1=3

PL2=3

A=2PL=2

M=↑↓

A=2PL=3

M=↑↓

A=2PL=1

A=AMBPL=1

A=AMBPL=2M=↑↓

A=GRPL=1

A=GRPL=2

A=1PL1=3

A=2PL1=1

A=1PL1=1

A=1PL1=2

One general for lightsOne general for motors

Command to every actuator with the same modality

A

PL

Page 28: Home BUS Light

29

WDS DIVISION

Extended command

Point-to-point extended command between different logical extensions

A=1PL1=1

A=1PL1=2

A=1PL1=1

A=1PL1=3

SCS/SCS

IN

OU

TMOD=2

I4=1

A=1PL1=2

PL2=2

SCS/SCSIN

OU

T

MOD=2I4=2

Local BUS

Private riser Local BUS

Extended command

A=1PL=1I=2

A=1PL=2I=1

A=1PL1=3

PL2=3

A=1PL1=2

A=1PL=3M=↑↓I=2

A=1PL1=3

PL2=3

A=1PL1=1

A=1PL=3M=↑↓I=CEN

Page 29: Home BUS Light

30

WDS DIVISION

Light function:

ON timed command

ON command

OFF command

Pushbutton command

ON / OFF command

Automation function:

UP / DOWN bistable command

UP / DOWN monostable command

Special commands

Configurator:

PUL

ON

OFF

O/I

M

1-8

Page 30: Home BUS Light

31

WDS DIVISION

Easy scenario with lights and motors– 4 scenarios per Unit (command)– 16 scenarios per DIN module (memory)– Configure the device (traditional-virtual)– Customizable by the end-user (push & learn)

Basic scenarios configuration

Easy to set-upPush & Learn

Scenario module

4 scenarios command

Page 31: Home BUS Light

32

WDS DIVISION

Slave configuration

You have to use SLAVE

1 relay actuator

2 actuators with the same address cannot exist!

Page 32: Home BUS Light

33

WDS DIVISION

Save the system state in black-out situation

• It needs an A/PL address• To save address it can be used in area 0

A=PL=

• 1 module for every system

(phisical extension included)

PL

A

1 to 9

0

Memory module

Memory module

Page 33: Home BUS Light

34

WDS DIVISION

System extensions

Page 34: Home BUS Light

35

WDS DIVISION

SCS system extended possibilities

One SCS system has Physical & Logical max possibilities which can be expanded because:– Physical: Distance & Current

– Logical: Address

The SCS system could be integrated with RADIO & LAN because:–If it is not possible to run the BUS

–Web access or smart phone control

BUS extension

RADIO extension

LAN extension

BUS extension

Page 35: Home BUS Light

36

WDS DIVISION

BUS extension for Current - Distance

One system has 1200mA & 500m

Physical extension to multiply the SCS possibilities

1200mA & 500m 1200mA & 500m 1200mA & 500m

1200mA & 500m 1200mA & 500m

M U L T I P L Y 2 T I M E S

M U L T I P L Y 3 T I M E S

Page 36: Home BUS Light

37

WDS DIVISION

Physical extensions rules: max 6A & 2.5km (4 interfaces maximum: 5 buses)

The SCS interface takes one available system address to separate 2 or more system sections

Physical extension MOD=1

I3 & I4 are the link address

All kind of command is interface transparent: see the table beside

Max 4 SCS interface: 5 times the max possibilities

56-99SCS/SCSIN

OU

T 34-5411-32 SCS/SCSIN

OU

T

Address 33 Address 55

133 155

PASSPASSAuxiliary

PASSPASSGeneral

PASSPASSGroup

PASSPASSArea

PASSPASSPoint to point

OUT ININ OUTCOMMAND

PASSPASSExtended

Page 37: Home BUS Light

38

WDS DIVISION

Physical extensions: extension 79 total address, 3.6A current and 1.5km bus distance available

Address 91-99

Private riser

Private riser

NL

Address 11-38

Address 41-88

Private riser

MOD=1I3=8I4=9

MOD=1I3=3I4=9

Page 38: Home BUS Light

39

WDS DIVISION

BUS extension for Address

One system has 81 address available

Logical extension to multiply the SCS possibilities

MULTIPLY 10 TIMES

810 address

Private riserLocal BUSES

Page 39: Home BUS Light

40

WDS DIVISION

LOCAL BUS SCS/SCSIN

OU

T

Address 300

23

LOCAL BUS SCS/SCSIN

OU

T

Address 200

22

LOCAL BUS SCS/SCSIN

OU

T

Address 100

12

Logical extensions rules: 810 address (9 interfaces maximum: 10 buses)

PR

IVA

TE

RIS

ER

Each SCS interface gives 1 digit more (hungered) to each local bus

Logical extension MOD=2

I4 is the interface address

Some commands are blocked in one direction: see the table

PASSPASSAuxiliary

STOPPASSGeneral

STOPPASSGroup

STOPSTOPArea

STOPPoint to point

OUT ININ OUTCOMMAND

STOP

PASSPASSExtended

Max 9 SCS interface with 10 buses

Page 40: Home BUS Light

41

WDS DIVISION

Logical extensions: example243 total address, 3.6A current and 1,5km bus distance available

Private riser

Address 011-099

LN

Local BUSAddress 111-199

Local BUSAddress 211-299

NL

MOD=2I4=2

MOD=2I4=1

Page 41: Home BUS Light

42

WDS DIVISION

Example: 2 logical and 1 physical extensions 242 total address, 4.8A current and 2km bus distance available

LN

Local BUSAddress 111-199

Private riser

Address 011-099

NL

Local BUSAddress 211-299 (- 155)

MOD=1I3=5 I4=5

MOD=2I4=2

MOD=2I4=1

Page 42: Home BUS Light

44

WDS DIVISION

Bus-Radio extension

Radio and bus system integrated means:– More installation flexibility

• Command wireless• No additional BUS cable

– Actuators flush mounting

SCS bus

Radio ZigBee

Page 43: Home BUS Light

45

WDS DIVISION

LAN extension

NL

LAN

IP 10.23.45.186

IP 10.23.45.182

Thanks to the web server it is possible to link BUS & LAN– Local control via smart phones– Local control via MHVISUAL synoptic software– Remote control via web-pages– OPEN integration with 3rd parties available

Page 44: Home BUS Light

46

WDS DIVISION

THE END