Home Automation - Bticino My Home Digital Solutions

68
SYSTEM ENRICH TO ELECTRICAL THE SOLUTIONS DIGITAL

description

123

Transcript of Home Automation - Bticino My Home Digital Solutions

  • SYSTEMENRICHTOELECTRICALTHE

    SOLUTIONSDIGITAL

  • THE SOLUTIONS 3

    THE SOLUTIONS

    10 AUTOMATION SOLUTION FOR 5 SHUTTERS With BUS/SCS technology With Zigbee technology

    20 AUTOMATION SOLUTION FOR 3 SHUTTERS AND 2 CURTAINS With BUS/SCS technology With Zigbee technology

    31 LIGHT SCENARIO SOLUTION With BUS/SCS technology With Zigbee technology

    50 LIGHT POINT ADDITION SOLUTION With Zigbee technology

    56 SOUND DIFFUSION SOLUTION 1 SOURCE With BUS/SCS technology

    61 SOUND DIFFUSION SOLUTION 2 MULTICHANNEL SOURCES With BUS/SCS technology

    CONTENTS

    WWW.BTICINO.COM

  • 4SOLUTIONSTHE ADVANTAGES

    of theThanks to our solutions it is possible to add new devices to the existing electric system, to expand and enrich the functions of the traditional system. This can be done using a wired or radio solution.

    AUTOMATION OF CURTAINS AND SHUTTERSTo control the movement of one or more shutters/curtains around the whole home. One single touch is enough to raise or lower all the shutters/curtains of your home.

    LIGHT SCENARIOSScenarios make life in your home much more simple and comfortable thanks to the simultaneous activation of several controls used daily.

  • THE SOLUTIONS 5

    Thanks to the scenario control, the user can prepare the room for relaxation, reading, watching a film, etc. by ordering with a single movement the switching on or off of certain lights.

    SOUND DIFFUSIONTo follow your favourite music program in each room of your home with a high sound quality, with perfect look integration.

    WWW.BTICINO.COM

  • 6TECHNOLOGY SELECTION of the

    WIRED BUSThe transmission of all information among the devices added to the traditional electric system is performed through a twisted pair called BUS. The BUS cable transmits the information and the power supply to the devices and can be installed together with the existing energy cables. This solution is particularly suited for new constructions, or when important refurbishments have taken place.

    WIRED BUS

    TECHNOLOGY SELECTION SELECTION

    WIRED

  • THE SOLUTIONS 7

    RADIO ZIGBEE

    RADIO ZIGBEEThanks to the radio transmission and the battery powering of controls, the devices easily integrate with the traditional electric system, without the need for any additional wiring. In this way the existing system can be integrated with the automation of lights and shutters.

    RADIO ZIGBEE

    WWW.BTICINO.COM

  • 8PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    DEVICE OPERATION DESCRIPTION

    LOADS WHICH CAN BE DRIVEN

    CONFIGURATION OF THE DEVICES

    SOLUTIONSGUIDEto the

  • THE SOLUTIONS 9

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    FUNCTIONAL DIAGRAM

    LIST OF DEVICES THAT MUST BE ORDERED

    Below are all the steps to follow for the best possible installation of the ready-made solutions that we offer.

    This document was created as a guide for the

    users, and to provide them with all the necessary information to enable

    them to enrich the electric system.

    WWW.BTICINO.COM

  • 22 2 2

    2

    2

    10

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    Management of 5 motorized shutters or curtains using individual controls and the general control. This solution is particularly suited for new constructions or refurbishments.

    In case control of several loads is required (shutters or curtains), or if several control points are to be installed, system expansion is also possible.

    Legend of symbols:

    Distribution board

    Load control(general control)

    Flush mounted actuator (single control)

    BUS - SCS cable 230 Vac cable Shutter motor Junction box

    Automation solution for 5 shutters with SCS BUS technology

    Studio

    Living Room HallwayBathroom

    Kitchen

    Second bathroom Child

    bedroom

    Bedroom

  • THE SOLUTIONS 11

    Actuator device for SINGLE control:

    for local control of each individual associated/connected shutter. The type of control depends on the configurator connected to the M1 socket: MONOSTABLE, press and hold down the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device, until the desired shutter position is reached. BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After the command has been sent, press the lower or upper key cover again to stop the shutter in the desired position.

    GENERAL control device:

    to control the opening or the closing of all shutters at the same time. Configure the control for use in BISTABLE mode.

    LOADS WHICH CAN BE DRIVEN

    NOTE: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

    The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.

    WARNING: the devices must only be configured when the system is not powered.

    NOTE: the reference code for the configurators is sold in kits of 10 pieces

    CONFIGURATION OF THE DEVICES

    Description of the configurators

    Configurator socket

    Configurator

    Pull-out handle

    DescriptionPower supply from BUS

    Absorption from BUS

    Dissipated power at maximum load

    Relay Type of load

    Flush mounted 2 relay actuator

    18 27 Vdc 13.5 mA 0.9 W

    C

    NO NO 2 A 500 W

    DEVICE OPERATION DESCRIPTION

    WWW.BTICINO.COM

  • NL230 Vac

    N

    L1 L2

    N

    L1 L2

    N

    L1 L2

    N

    L1 L2

    N

    L1 L2

    BUS SCS

    NL

    230 Vac

    1

    2

    4

    3 3 3 3 3

    12

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

    NOTE (*):configure M1= 8 for BISTABLE operationconfigure M1= qr M for MONOSTABLE operation configure M1= qr for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s. Up-down to the end of stroke if the control is pressed for more than 1.5 s.

    Description q.ty BTicino Legrand Size (DIN)

    1 Mini Power supply 230 Vac 1 E49 03567 2 modules

    1 Power supply 110/127 Vac 1 346031 2 modules

    TOTAL SIZE 2 modules

    List of DIN module devices

    Mini Power supply

    General control

    Single control

    Single control

    Single control

    Single control

    Single control

    Vac

    Vac

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    2 Control for single and double loads 1 L4652/2 H4652/2 573974 67241

    3 Flush mounted actuator 2 relays 5 LN4671M2 H4671M2 573961 67249

    Key cover UP/DOWN 2 modules 6

    N4911M2AHN

    NT4911M2AHN

    L4911M2AHN

    HD4911M2AH

    HC4911/2AH

    HS4911/2AH

    574384

    574385

    68108

    68408

    4 SCS-BUS cable 1 L4669 L4669 49231 49231

    Configurator GEN 1 3501/GEN 3501/GEN 49210 49210

    Configurator 1 1 3501/1 3501/1 49201 49201

    Configurator 2 1 3501/2 3501/2 49202 49202

    Configurator 3 1 3501/3 3501/3 49203 49203

    Configurator 5 1 3501/5 3501/5 49205 49205

    Configurator 6 1 3501/6 3501/6 49206 49206

    Configurator 8 1 3501/8 3501/8 49208 49208

    Configurator qr 1 3501/T 3501/T 49220 49220Configurator qr M 1 3501/TM 3501/TM 49221 49221Pull-out handle 1 3502 3502 49265 49265

    Ring 6 - - -68083

    68383

    List of flush mounted devices

    FUNCTIONAL DIAGRAM

    LIST OF DEVICES THAT MUST BE ORDERED

    List of DIN module devices

    Vac

    Vac

    List of flush mounted devices

    A1 = GENM1 = qr

    A1 = 5PL1 = 1 M1 = (*)

    A1 = 5PL1 = 2 M1 = (*)

    A1 = 5PL1 = 3 M1 = (*)

    A1 = 6PL1 = 1 M1 = (*)

    A1 = 6PL1 = 2 M1 = (*)

  • MPRI

    035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA

    SCS

    PL1M1

    A1

    PL2M2

    A2

    BUS

    BUS

    Vac

    MN

    L1

    L2

    LN

    BUS

    THE SOLUTIONS 13

    110

    1) Control device for the general control of 5 shutters.

    Actuator with key cover for local control

    Junction box

    NOTE 1): recommended height

    Power supply

    160

    1)

    Apartment switchboard

    Control

    Rear view

    Mini Power supply

    NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

    Front view

    Actuator

    2 A max500 W max

    Rear view

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    Control

    110

    1)

    Junction box

    WWW.BTICINO.COM

  • 22 2 2

    2

    2

    14

    Automation solution for 5 shutters with ZigBee technologyUsing the Zigbee technology it is possible to add a control point (e.g. a general control) to manage shutters, by simply replacing the traditional devices with radio devices, without the need to modify the existing wiring.

    The new general control consists of a surface mounted radio control.

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    Studio

    Living Room HallwayBathroom

    Kitchen

    Second bathroom Child

    bedroom

    Bedroom

    Legend of symbols:

    Distribution board

    Flush mounted radio actuator (single control)

    230 Vac cable

    Shutter motor Junction boxRadio control(general control)

    DEVICE OPERATION DESCRIPTION

    Single control radio actuator:

    for local control of each individual associated/connected shutter. The control type can be: BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After activating the control, press the bottom left key to stop the shutter in the desired position.

    By pressing and holding down for more that one second the UP or the DOWN keys, it is possible to adjust the position of the blades.

    General control:for radio control of the opening or closing of all the shutters at the same time. This is a BISTABLE type control, the same as described for the single actuator.

    STOP control

    UP control

    DOWN control

  • 4 s

    THE SOLUTIONS 15

    Description Power supply / Frequency Shutter motor

    Radio actuator for shutter automations

    230 Vac@50/60 HzMAX 500 VA MIN 270 VA

    110 Vac@50/60 HzMax 250 VAMin 135 VA

    PROCEDURE:

    1. Remove any key covers present.

    2. Select the actuator device that will act as a Coordinator,

    and press the corresponding NETWORK KEY for 4

    seconds.

    The Configuration of radio ZigBee devices is performed in three stages:

    1. Selection of the coordinator device and network

    creation. The coordinator device MUST be connected

    to the electric power line.

    2. Adding the devices to the network

    3. Association of the devices

    1 - Selection of the coordinator device and network creation

    This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

    To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.

    LOADS WHICH CAN BE DRIVEN

    CONFIGURATION OF THE DEVICES

    LEDS AND PUSHBUTTONS REQUIRED FOR THE CONFIGURATION

    NETWORK pushbutton

    LEARNING pushbutton

    ON/OFF control key

    LED STATUS

    OFF

    ON STEADY

    FLASHING SLOWLY (1s)

    FLASHING QUICKLY (0.25s)

    FLASHING (60ms)

    FLASHING 3 TIMES (3s)

    3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.

    4. Create the network by setting the devices that will be included, as indicated in the following page.

    LEARNING indicator LED

    NETWORK indicator LED

    Coordinator

    Coordinator

    4 s

    WWW.BTICINO.COM

  • A PL

    16

    2. Repeat the above procedure for all devices to include in the network.

    3. To complete the procedure press the NETWORK KEY of the Coordinator device; The corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.

    2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.

    The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.

    3 s CoordinatorDevice

    Device

    To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,

    while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.

    Device Coordinator Device Device

    CHECKING THE DEVICES BELONGING TO THE NETWORK

  • A PL

    A PL

    A PL

    ML2

    5

    3

    A PL

    ML2

    5

    3

    ML2

    5

    3

    THE SOLUTIONS 17

    3. Press the KEY (top right). The LEARNING LED (green) will start flashing quickly.

    5. Press the UP KEY (top right) on the same ACTUATOR, the connected load activates and the shutter goes UP. The LEARNING LED (green) will go from flashing slowly to flashing quickly.

    7. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.

    1. If fitted, remove the key covers of the involved devices. 2. Press the LEARNING KEY of the RADIO CONTROL, the

    LEARNING LED (green) will flash slowly. Wait at least 1 second.

    Control

    Actuator

    General control

    6. Repeat the operations at points 4 and 5 for all actuators to associate to the general control.

    4. Press the LEARNING KEY of the 1st ACTUATOR (shutters), the LEARNING LED (green) will flash slowly.

    Control

    Control

    Actuator

    Actuator

    WWW.BTICINO.COM

  • N L

    1

    2

    18

    FUNCTIONAL DIAGRAM

    Flush mounted radio actuator

    Motorized shutter

    NOTE: Repeat the connection for all 5 shutters.General control

    LIST OF DEVICES THAT MUST BE ORDERED

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    1Radio actuator for shutter automation

    5 LN4595 H4595573840 573841

    67263

    2Radio control for shutter automation

    3N4599N (round cover plate)L4599N (square cover plate)

    HA4599 (rectangular cover plate)HB4599 (round cover plate)

    573842 573843

    67264

    Module key cover for actuator and UP/DOWN control

    8N4911AHN NT4911AHN L4911AHN

    HD4911AH HC4911AH HS4911AH

    supplied68100 68400

    Module key cover for actuator and NEUTRAL control

    8N4911AN NT4911AN L4911AN

    HD4915 HC4915 HS4915

    supplied68081 68381

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

  • TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    M

    N L

    ML2

    5

    3

    THE SOLUTIONS 19

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    NOTA 1): recommended height

    Radio actuator

    Junction box

    Radio control

    Maximum distancesThe maximum distance between 2 devices is:150 metres on free field.

    15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

    Shutter actuator

    150 metres

    Radio control

    15 metres

    Wall

    Shutter actuator

    Radio control

    N

    L

    N

    L

    110

    1)

    110

    1)

    WWW.BTICINO.COM

  • 20

    2

    2 2 2

    2

    2

    Actuator device for SINGLE control:

    for local control of each individual associated/connected shutter/curtain. The type of control depends on the configurator connected to the M1 socket: MONOSTABLE, press and hold down the top section (shutter/curtain UP) or the bottom section (shutter/curtain DOWN) of the key cover of the actuator device, until the desired shutter/curtain position is reached. BISTABLE, press and release the top section (shutter/curtain UP) or the bottom section (shutter/curtain DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter/curtain motor. After the command has been sent, press the lower or upper key cover again to stop the shutter/curtain in the desired position.

    GENERAL control device:

    to control the opening or the closing of all shutters/curtain at the same time. Configure the control for use in BISTABLE mode.

    Automation solution for 3 shutters and 2 curtains with SCS BUS technologyManagement of 3 motorized shutters and 2 motorized curtains, with individual controls and 2 independent general controls. This solution is particularly suited for new constructions or refurbishments.

    In case control of several users is required (shutters or curtains), or if several control points are to be installed, system expansion is also possible.

    Load control(comandi generali)

    Flush mounted actuator (single control)

    SCS - BUScable

    230 Vaccable

    Shutter motor

    Curtains motor

    Junction boxDistribution board

    Legend of symbols:

    Studio

    Living Room

    HallwayBathroom

    Kitchen

    Second bathroom Child

    bedroom

    Bedroom

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    DEVICE OPERATION DESCRIPTION

  • THE SOLUTIONS 21

    4

    N

    L1 L2

    N

    L1 L2

    N

    L1 L2

    N

    L1 L2

    N

    L1 L2

    2 3 3 3 3 3

    NL

    1

    BUS SCS

    NL

    DescriptionPower supply from BUS

    Absorption from BUS

    Dissipated power at maximum load

    Relay Type of load

    Flush mounted 2 relay actuator

    18 27 Vdc 13.5 mA 0.9 W

    C

    NO NO 2 A 500 W

    NOTE: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

    Description of the configurators

    Configurator socket

    Configurator

    Pull-out handle

    The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.

    WARNING: the devices must only be configured when the system is not powered.

    NOTE: the reference code for the configurators is sold in kits of 10 pieces.

    LOADS WHICH CAN BE DRIVEN

    CONFIGURATION OF THE DEVICES

    FUNCTIONAL DIAGRAM

    NOTE (*):configure M1= 8 for BISTABLE operationConfigure M1= qr M for MONOSTABLE operation Configure M1= qr for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s. Up-down to the end of stroke if the control is pressed for more than 1.5 s.

    Mini Power supply

    General control

    Single control

    Single control

    Single control

    Single control

    Single control

    A1 = 5PL1 = 1 M1 = (*)

    A1 = AMBPL1 = 5M1 = qrA2 = AMBPL2 = 6M2 = qr

    A1 = 5PL1 = 2 M1 = (*)

    A1 = 5PL1 = 3 M1 = (*)

    A1 = 6PL1 = 1 M1 = (*)

    A1 = 6PL1 = 2 M1 = (*)

    Vac

    Vac

    WWW.BTICINO.COM

  • 22

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

    Description q.ty BTicino Legrand Size (DIN)

    1 Mini Power supply 230 Vac 1 E49 03567 2 modules

    1 Power supply 110/127 Vac 1 346031 2 modules

    TOTAL SIZE 2 modules

    List of DIN module devices

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    2 Control for single and double loads 1 L4652/2 H4652/2 573974 67241

    3 Flush mounted actuator 2 relays 5 LN4671M2 H4671M2 573961 67249

    Key cover UP/DOWN 2 modules 6N4911M2AHN NT4911M2AHN L4911M2AHN

    HD4911M2AH HC4911/2AH HS4911/2AH

    574384

    574385

    68108

    68408

    1 module UP/DOWN key 6N4911AHM NT4911AHM L4911AH

    HD4911AH HC4911AH HS4911AH

    574362

    574363

    68100

    68400

    4 SCS-BUS cable 1 L4669 L4669 49231 49231

    Configurator GEN 1 3501/GEN 3501/GEN 49210 49210

    Configurator 1 1 3501/1 3501/1 49201 49201

    Configurator 2 1 3501/2 3501/2 49202 49202

    Configurator 3 1 3501/3 3501/3 49203 49203

    Configurator 5 1 3501/5 3501/5 49205 49205

    Configurator 6 1 3501/6 3501/6 49206 49206

    Configurator 8 1 3501/8 3501/8 49208 49208

    Configurator qr 1 3501/T 3501/T 49220 49220Configurator qr M 1 3501/TM 3501/TM 49221 49221Configurator AMB 1 3501/AMB 3501/AMB 49221 49221

    Pull-out handle 1 3502 3502 49265 49265

    Ring 6 - - -68083

    68383

    List of flush mounted devices

    LIST OF DEVICES THAT MUST BE ORDERED

  • THE SOLUTIONS 23

    PL1M1

    A1

    PL2M2

    A2

    BUS

    MN

    L1

    L2

    LN

    BUS

    M

    PRI

    035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA

    SCS

    BUS

    Vac

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    Actuator

    2 A max500 W max

    Rearview

    Actuator with key cover for local control

    Junction box

    Control device for the general control of three shutters and the general control of two curtains.

    Control

    Rear view

    Apartment switchboard

    Power supply

    Front view

    Mini Power supply

    NOTE 1): recommended height NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

    110

    1)

    110

    1)

    160 1)

    WWW.BTICINO.COM

  • 24

    2

    2 2 2

    2

    2

    Automation solution for 3 shutters and 2 curtains with ZigBee technologyUsing the Zigbee technology it is possible to add a control point (e.g. a general control) to manage shutters and curtains, by simply replacing the traditional devices with radio devices, without the need to modify the existing wiring.

    The new general control consists of a surface mounted radio control.

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    Distribution board

    Load control(general radio)

    Flush mounted radio actuator (single control)

    230 Vac cable

    Shutter motor

    Curtains motor

    Junction box

    Legend of symbols:

    Studio

    Living Room

    HallwayBathroom

    Kitchen

    Second bathroom Child

    bedroom

    Bedroom

    UP control

    DOWN control

    STOP control

    Single control radio actuator:

    for local control of each individual associated/connected shutter. The control type can be: BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After activating the control, press the bottom left key to stop the shutter in the desired position.

    By pressing and holding down for more that one second the UP or the DOWN keys, it is possible to adjust the position of the blades.

    General control:for radio control of the opening or closing of all the shutters at the same time. This is a BISTABLE type control, the same as described for the single actuator.

    DEVICE OPERATION DESCRIPTION

  • THE SOLUTIONS 25

    4 s

    LOADS WHICH CAN BE DRIVEN

    Description Power supply / Frequency Shutter/Curtain motor

    Radio actuator for shutter/curtain automations

    230 Vac@50/60 HzMAX 500 VA MIN 270 VA

    110 Vac@50/60 HzMax 250 VAMin 135 VA

    CONFIGURATION OF THE DEVICES

    PROCEDURE:

    1. Remove any key covers present.

    2. Select the actuator device that will act as a Coordinator,

    and press the corresponding NETWORK KEY for 4

    seconds.

    The Configuration of radio ZigBee devices is performed in three stages:

    1. Selection of the coordinator device and network

    creation. The coordinator device MUST be connected

    to the electric power line.

    2. Adding the devices to the network

    3. Association of the devices

    1 - Selection of the coordinator device and network creation

    This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

    To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.

    3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.

    4. Create the network by setting the devices that will be included, as indicated in the following page.

    LEARNING indicator LED

    NETWORK indicator LED

    LEDS AND PUSHBUTTONS REQUIRED FOR THE CONFIGURATION

    NETWORK pushbutton

    LEARNING pushbutton

    ON/OFF control key

    Coordinator

    Coordinator

    LED STATUS

    OFF

    ON STEADY

    FLASHING SLOWLY (1s)

    FLASHING QUICKLY (0.25s)

    FLASHING (60ms)

    FLASHING 3 TIMES (3s)

    WWW.BTICINO.COM

  • 26

    A PL

    3 s

    To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,

    2. Repeat the above procedure for all devices to include in the network.

    3. To complete the procedure press the NETWORK KEY of the Coordinator device; the corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.

    while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.

    Device Coordinator Device Device

    2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.

    The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.

    CoordinatorDevice

    Device

    CHECKING THE DEVICES BELONGING TO THE NETWORK

  • THE SOLUTIONS 27

    A PL

    A PL

    A PL

    ML2

    5

    3

    A PL

    ML2

    5

    3

    ML2

    5

    3

    5. Press the UP KEY (top right) on the same ACTUATOR, the connected load activates and the shutter goes UP. The LEARNING LED (green) will go from flashing slowly to flashing quickly.

    1. If fitted, remove the key covers of the involved devices. 2. Press the LEARNING KEY of the RADIO CONTROL, the

    LEARNING LED (green) will flash slowly. Wait at least 1 second.

    General control for 3 shutters

    4. Press the LEARNING KEY of the 1st ACTUATOR (shutters), the LEARNING LED (green) will flash slowly.

    3. Press the KEY (top right). The LEARNING LED (green) will start flashing quickly.

    Control

    Control

    Control

    Actuator

    Actuator

    Actuator

    7. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.

    6. Repeat the operations at points 4 and 5 for all actuators to associate to the general control.

    WWW.BTICINO.COM

  • 28

    A PL

    A PL

    A PL

    ML2

    5

    3

    A PL

    ML2

    5

    3

    ML2

    5

    3

    4. Press the LEARNING KEY of the 1st ACTUATOR (curtains), the LEARNING LED (green) will flash slowly.

    3. Press the KEY (top right). The LEARNING LED (green) will start flashing quickly.

    5. Press the UP KEY (top right) on the same ACTUATOR, the connected load activates and the curtains goes UP. The LEARNING LED (green) will go from flashing slowly to flashing quickly.

    1. If fitted, remove the key covers of the involved devices. 2. Press the LEARNING KEY of the RADIO CONTROL, the

    LEARNING LED (green) will flash slowly. Wait at least 1 second.

    Control

    Control

    Control

    ActuatorActuator

    Actuator

    General control for 2 curtains

    7. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.

    6. Repeat the operations at points 4 and 5 for all actuators to associate to the general control.

  • THE SOLUTIONS 29

    N L N L

    1 1

    !

    FUNCTIONAL DIAGRAM

    Flush mounted actuator

    Motorized shutter

    Motorized curtain

    NOTE: Repeat the connection for all shutters and curtains.

    General shutter control

    General curtain control

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    1Radio actuator for shutter automation

    5 LN4595 H4595573840 573841

    67263

    2Radio control for shutter automation

    3N4599N (round cover plate)L4599N (square cover plate)

    HA4599 (rectangular cover plate)HB4599 (round cover plate)

    573842 573843

    67264

    Module key cover for actuator and UP/DOWN control

    11N4911AHN NT4911AHN L4911AHN

    HD4911AH HC4911AH HS4911AH

    supplied68100 68400

    Module key cover for actuator and NEUTRAL control

    11N4911AN NT4911AN L4911AN

    HD4915 HC4915 HS4915

    supplied68081 68381

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

    LIST OF DEVICES THAT MUST BE ORDERED

    WWW.BTICINO.COM

  • 30

    N

    TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    L

    N

    TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    L

    110

    1)

    M

    110

    1)

    N L

    ML2

    5

    3

    2

    2

    2 2 2 2

    NOTA 1): recommended height

    Radio actuator

    Junction box

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    Radio control

    Shutter actuator

    150 metres

    Maximum distancesThe maximum distance between 2 devices is: 150 metres on free field.

    15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

    Radio controlRadio control

    15 metres

    Wall

    Shutter actuator

  • EDC

    B

    A

    H G

    F

    THE SOLUTIONS 31

    Light scenario solution with star wiring and SCS BUS technologyThe light scenario management solution makes it possible to recreate the desired atmosphere. Simply save light scenarios in the scenario module based on the desired ambience (e.g. relax, reading, TV Vision,

    wake-up), so that they may be recalled with a simple movement using the Scenario Control device. Solution realised with star wiring. All the actuators are in DIN module.

    Scenario module:

    it can be used to manage the scenarios created, modified and activated using the scenario control. Up to a maximum of 16 scenarios may be saved inside.

    Scenario control:

    Its a device that gives the possibility of recalling, changing, or modifying the scenarios saved in the Scenario Module. With the scenario control it is possible to save up to 4 scenarios.

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    DEVICE OPERATION DESCRIPTION

    Load controlDistribution board

    Scenario control

    Lamp BUS - SCS cable 230 Vac cable Junction box

    Legend of symbols:

    Studio

    Living RoomHallway

    Kitchen

    Second bathroom

    Child bedroom

    Bedroom

    Bathroom

    WWW.BTICINO.COM

  • 32

    DescriptionPower supply from BUS

    Absorption from BUS

    Dissipated power at maximum load

    Type of load

    2 relay actuator

    18 27 Vdc28 MA

    (SINGLE LOADS)1.7 W

    6 A / 1400 W (incandescence lamps and energy saving halogens) 10 a / 2300 w (resistive loads) 1 a / 250 w (linear fluorescent lamps) 250 w max 4 lampade (compact fluorescent lamps) 1 a / 250 w (electronic transformers) 2 a cos 0.5 / 500 va (ferromagnetic transformers)

    2 x 400 W Multi load Dimmer Actuator

    100 - 240 Vac @ 50/60 Hz

    5 mA 8 W

    1.7 A / 400 W (incandescence lamps and energy saving halogens) 1.7 A / 400 W (electronic transformers) 1.7 A / 400 W (ferromagnetic transformers)

    WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

    The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.

    WARNING: the devices must only be configured when the system is not powered.

    NOTE: the reference code for the configurators is sold in kits of 10 pieces

    Description of the configurators

    Configurator socket

    Configurator

    Pull-out handle

    Configurator

    Configurator socket

    Pull-out handle

    CONFIGURATION OF THE DEVICES

    LOADS WHICH CAN BE DRIVEN

  • ART.F420ART.F411/2

    1 2 31 2 3 4

    ART.F411/2

    1 2 3 41 2 3 4

    ART.F411/2

    1 2 31 2 3 4

    ART.F411/2

    1 2 3 41 2 3 4

    ART.F411/2

    1 2 31 2 3 4

    ART.F411/2

    1 2 3 41 2 3 4

    ON/+

    OFF/-

    RL/C

    F417U2

    2x400 VA

    ON/+

    OFF/-

    MG2PL2G1

    PL1A

    NL

    NL

    A B C D E F G H

    1

    2

    3

    4 4

    4

    7

    5 5 5 5 5

    5

    5

    56 6

    A A B C D E F G H

    THE SOLUTIONS 33

    FUNCTIONAL DIAGRAM

    A1 = GENPL1 = M1 = O/IA2 = 1PL2 = 1M2 = O/I

    AF = 1PL1 = 1M1 = O/IA2 = 1PL2 = 2M2 = O/I

    A = PL = 1M = 1(*)N = DEL =

    A1 = 2PL1 = 1M1 = O/IA2 = PL2 = M2 =

    A1 = 2PL1 = 2M1 = O/IA2 = PL2 = M2 =

    A1 = 3PL1 = 1M1 = O/IA2 = PL2 = M2 =

    A1 = 3PL1 = 2M1 = O/IA2 = PL2 = M2 =

    A = PL = 1M = 2(*)N = DEL =

    A1 = 4PL1 = 1M1 = O/IA2 = PL2 = M2 =

    A1 = 4PL1 = 2M1 = O/IA2 = PL2 = M2 =

    A = 2PL1 = 1PL2 = 2G =

    A = 3PL1 = 1PL2 = 2G =

    A = 4PL1 = 1PL2 = 2G =

    A1 = -PL1 = 1

    A = 1PL1 = 1G1 = -PL2 = 2G2 = -M = -

    Mini Power supply

    Vac

    VacScenario module

    Dimmer actuator 2 relay

    actuator2 relay actuator

    2 relay actuator

    Control Control Control Control ControlScenario control

    NOTE(*): by inserting the same configurator in M, the scenario controls will activate the same scenarios.

    Control ControlScenario control

    WWW.BTICINO.COM

  • 34

    LIST OF DEVICES THAT MUST BE ORDERED

    List of flush mounted devices

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    5 Control for single and double loads 8 L4652/2 H4652/2 573974 67241

    6 Scenario control 2N4680 NT4680 L4680

    HD4680 HC4680 HS4680

    573902 573903

    67217 67218

    Key cover ON-OFF-GEN regulation 1 module

    1N4911AFN NT4911AFN L4911AFN

    HD4911AF HC4911AF HS4911AF

    574373 (left) 574372 (left)

    68105 (left) 68405 (left)

    Key cover ON-OFF regulation 1 module

    3N4911AIN NT4911AIN L4911AIN

    HD4911AI HC4911AI HS4911AI

    573964 (left) 573960 (right) 573965 (left) 573961 (right)

    68264 (left) 68265 (right) 68564 (left) 68565 (right)

    Key cover ON-OFF 2 modules 6N4911/2AGNNT4911/2AGNL4911/2AGN

    HD4911M2AGHC4911/2AG HS4911/2AG

    574382 574383

    68085 68385

    7 BUS - SCS cable 1 L4669 L4669 49231 49231

    Configurator GEN 1 3501/GEN 3501/GEN 49210 49210

    Configurator 1 1 3501/1 3501/1 49201 49201

    Configurator 2 1 3501/2 3501/2 49202 49202

    Configurator 3 1 3501/3 3501/3 49203 49203

    Configurator 4 1 3501/4 3501/4 49204 49204

    Configurator 0/1 1 3501/01 3501/01 49216 49216

    Pull-out handle 1 3502 3502 49265 49265

    Ring 8 - - - 68083 68383

    Description q.ty BTicino Legrand Size(DIN)

    1 Mini Power supply 230 Vac 1 E49 03567 2 modules

    1 Power supply 110/127 Vac 1 346031 2 modules

    2 Scenario module 1 F420 03551 2 modules

    3 2 x 400 W Multi load Dimmer Actuator 1 F417U2 02622 6 modules

    4 2 relay actuator 3 F411/2 03842 6 modules

    TOTAL SIZE 16 modules

    List of DIN module devices

  • ON

    OFF

    PRI

    035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA

    SCS

    PL1M1

    A1

    PL2M2

    A2

    BUS

    ON

    OFF

    ON

    OFF

    THE SOLUTIONS 35

    WIRING AND ACTIVATION OF THE DEVICES

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    Front view

    Mini Power supply

    NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

    230 Vac

    BUS

    Apartment switchboard

    Power supply and DIN actuator

    NOTE 1): recommended height

    Control device for the management of lights.

    Control

    Rear viewScenario control device

    Dimmer light control device

    160 1)

    110 1)

    WWW.BTICINO.COM

  • ON

    OFF

    ON

    OFF

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    36

    Procedure for programming a scenario: Procedure for deleting one or more scenarios:

    1. In the scenario module press the programming enable pushbutton.

    The corresponding LED turns green: the module is enabled.

    2. Press the key to program for more than 4 seconds.

    When the LED turns on release the key. The LED will start flashing, confirming that the programming mode is active.

    3. Set the sequence of the commands making up the scenario.

    t > 4 sec.

    Press and hold down the key for the scenario to remove, waiting for the LED to come on and then to start FLASHING QUICKLY.To cancel all the scenarios stored in the scenario module press the reset pushbutton of the module.

    In the scenario module press the progr amming enable pushbutton.

    The corresponding LED turns green: the module is enabled.

    t > 8 sec.

    To add, modify, or remove a command from the scenario repeat the sequence.

    4. Press the key to complete programming.

    To activate the scenario press the corresponding key.

    At the end of programming it is recommended to disable the possibility of modifying the scenarios, using the enable/disable pushbutton of the scenario module (F420). The corresponding LED turns red

    ON

    ON

    ON

    ON

  • Studio

    Living Room

    Kitchen

    Second bathroom

    Child bedroom

    Bedroom

    Bathroom

    EDC

    B

    A

    H G

    F

    THE SOLUTIONS 37

    Legend of symbols:

    Light scenario solution with distributed wiring and SCS BUS technologyThe light scenario management solution makes it possible to recreate the desired atmosphere. Simply save light scenarios in the scenario module based on the desired ambience (e.g. relax, reading, TV Vision, wake-up), so that

    they may be recalled with a simple movement using the Scenario Control device. Solution created with distributed wiring. Flush mounted actuators are used when possible.

    Scenario module:

    it can be used to manage the scenarios created, modified and activated using the scenario control. Up to a maximum of 16 scenarios may be saved inside.

    Scenario control:

    Its a device that gives the possibility of recalling, changing, or modifying the scenarios saved in the Scenario Module. With the scenario control it is possible to save up to 4 scenarios.

    Load controlDistribution board

    Scenario control

    Lamp BUS - SCS cable

    230 Vac cable

    Junction box

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    DEVICE OPERATION DESCRIPTION

    Studio

    Living Room Hallway

    Kitchen

    Second bathroom

    Child bedroom

    Bedroom

    Bathroom

    DEVICE OPERATION DESCRIPTION

    WWW.BTICINO.COM

  • 38

    DescriptionPower supply from BUS

    Absorption from BUS

    Dissipated power at maximum load

    Type of load

    2X400 W Multiload Dimmer Actuator

    18 27 Vdc28 MA

    (SINGLE LOADS)8 W

    6 a / 1400 w (incandescence lamps and energy saving halogens) 10 a / 2300 w (resistive loads) 1 a / 250 w (linear fluorescent lamps) 250 w max 4 lampade (compact fluorescent lamps) 1 a / 250 w (electronic transformers) 2 a cos 0,5 / 500 va (ferromagnetic transformers)

    Control actuator

    18-27 Vdc 14 mA 8 W

    1.7 A / 400 W (incandescence lamps and energy saving halogens) 1.7 A / 400 W (electronic transformers) 1.7 A / 400 W (ferromagnetic transformers)

    WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

    The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.

    WARNING: the devices must only be configured when the system is not powered.

    NOTE: the reference code for the configurators is sold in kits of 10 pieces.

    LOADS WHICH CAN BE DRIVEN

    CONFIGURATION OF THE DEVICES

    Description of the configurators

    Configurator socket

    Configurator

    Pull-out handle

    Pull-out handle

    Configurator

    Configurator socket

  • ART.F420

    ON/+

    OFF/-

    RL/C

    F417U2

    2x400 VA

    ON/+

    OFF/-

    MG2PL2G1

    PL1A

    NL

    NL 1

    2

    3

    7

    5

    5

    6

    A B

    C

    D E F G H

    A A B

    C D E F G H

    4 4 4 4 4 4

    6

    ART.F420

    ON/+

    OFF/-

    RL/C

    F417U2

    2x400 VA

    ON/+

    OFF/-

    MG2PL2G1

    PL1A

    NL

    NL

    C D E F G H

    A A B

    THE SOLUTIONS 39

    FUNCTIONAL DIAGRAM

    Mini Power supply Scenario

    moduleDimmer actuator

    Actuator/ Control

    Actuator/ Control

    Actuator/ Control

    Actuator/ Control

    Actuator/ Control

    A1 = 2PL1 = 1M1 = O/IA2 = PL2 = M2 =

    A1 = 2PL1 = 2M1 = O/IA2 = PL2 = M2 =

    A1 = 3PL1 = 1M1 = O/IA2 = PL2 = M2 =

    A1 = 3PL1 = 2M1 = O/IA2 = PL2 = M2 =

    A1 = 4PL1 = 1M1 = O/IA2 = PL2 = M2 =

    A1 = 4PL1 = 2M1 = O/IA2 = PL2 = M2 =

    A1 = PL1 = 1

    A = 1PL1 = 1G1 = PL2 = 2G2 = M =

    Actuator/ Control

    A1 = GENPL1 = M1 = O/IA2 = 1PL2 = 1M2 = O/I

    AF = 1PL1 = 1M1 = O/IA2 = 1PL2 = 2M2 = O/I

    A = PL = 1M = 1(*)N = DEL =

    Control Control Scenario control

    Scenario control

    A = PL = 1M = 2(*)N = DEL =

    NOTE(*): by inserting the same configurator in M, the scenario controls will activate the same scenarios.

    Vac

    Vac

    WWW.BTICINO.COM

  • 40

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    4 Flush mounted actuator/control 6 LN4671M2 H4671M2 573961 67249

    5 Single and double load control 2 L4652/2 H4652/2 573974 67241

    6 Scenario control 2N4680 NT4680 L4680

    HD4680 HC4680 HS4680

    573902 573903

    67217 67218

    Key cover ON-OFF-GEN regulation 1 module

    1N4911AFN NT4911AFN L4911AFN

    HD4911AF HC4911AF HS4911AF

    574373 (left) 574372 (left)

    68105 (left) 68405 (left)

    Key cover ON-OFF regulation 1 module

    3N4911AIN NT4911AIN L4911AIN

    HD4911AI HC4911AI HS4911AI

    573964 (left) 573960 (right) 573965 (left) 573961 (right)

    68264 (left) 68265 (right) 68564 (left) 68565 (right)

    Key cover ON-OFF 2 modules 6N4911/2AGNNT4911/2AGNL4911/2AGN

    HD4911M2AGHC4911/2AG HS4911/2AG

    574382 574383

    68085 68385

    7 BUS - SCS cable 1 L4669 L4669 49231 49231

    Configurator GEN 1 3501/GEN 3501/GEN 49210 49210

    Configurator 1 1 3501/1 3501/1 49201 49201

    Configurator 2 1 3501/2 3501/2 49202 49202

    Configurator 3 1 3501/3 3501/3 49203 49203

    Configurator 4 1 3501/4 3501/4 49204 49204

    Configurator 0/1 1 3501/01 3501/01 49216 49216

    Pull-out handle 1 3502 3502 49265 49265

    Ring 8 - - - 68083 68383

    List of flush mounted devices

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

    Description q.ty BTicino Legrand Size(DIN)

    1 Mini Power supply 230 Vac 1 E49 03567 2 modules

    1 Power supply 110/127 Vac 1 346031 2 modules

    2 Scenario module 1 F420 03551 2 modules

    3 2 x 400 W Multi load Dimmer Actuator 1 F417U2 02622 6 modules

    TOTAL SIZE 10 modules

    List of DIN module devices

    LIST OF DEVICES THAT MUST BE ORDERED

  • PRI

    035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA

    SCS

    PL1M1

    A1

    PL2M2

    A2

    BUS

    ON

    OFF

    ON

    OFF

    THE SOLUTIONS 41

    Apartment switchboard

    Power supply and DIN actuator

    Scenario control device

    Dimmer light control device

    NOTE 1): recommended heightNOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedica-ted thermal magnetic protection circuit breaker.

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    Control

    Rear view

    Front view

    Mini Power supply

    230 Vac

    BUS

    160 1)

    110 1

    )

    WWW.BTICINO.COM

  • ON

    OFF

    ON

    OFF

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    42

    ON

    OFF

    ON

    OFF

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    DEL

    ART.F420

    Procedure for programming a scenario:

    1. In the scenario module press the programming enable pushbutton.

    The corresponding LED turns green: the module is enabled.

    2. Press the key to program for more than 4 seconds.

    When the LED turns on release the key. The LED will start flashing, confirming that the programming mode is active.

    To add, modify, or remove a command from the scenario repeat the sequence.

    3. Set the sequence of the commands making up the scenario.

    4. Press the key to complete programming.

    To activate the scenario press the corresponding key.

    Procedure for deleting one or more scenarios:

    Press and hold down the key for the scenario to remove, waiting for the LED to come on and then to start FLASHING QUICKLY.To cancel all the scenarios stored in the scenario module press the reset pushbutton of the module.

    In the scenario module press the programming enable pushbutton.

    The corresponding LED turns green: the module is enabled.

    ON

    ON

    At the end of programming it is recommended to disable the possibility of modifying the scenarios, using the enable/disable pushbutton of the scenario module (F420). The corresponding LED turns red.

    t > 4 sec.

    ON

    t > 8 sec.

    ON

  • ON

    OFF

    THE SOLUTIONS 43

    DIMMER radio actuator for light control:

    for the local control of lamps and loads.Press and release the ON key to enable the load at 66% of its power. To increase the power at the maximum level, hold down the key. Press and release the OFF key to enable the load at 33% of its power. To decrease the power down to the minimum level, hold down the key.

    Press the left key to switch the load on and off.

    Legend of symbols:

    Distribution board

    Radio actuator 230 Vac cableLampScenario radio control

    ON and adjustment pushbutton

    OFF and adjustment pushbutton

    ON/OFF pushbutton

    Scenario 2

    Scenario 4Scenario 3

    Scenario 1

    Scenario management radio control:

    for the management of 4 scenarios, which can be saved and recalled using the control itself, or a remote control.

    Radio remote control:

    with 4 pushbuttons for scenario control.

    Scenario 1

    Scenario 2

    Scenario 3Scenario 4

    Light scenario solution with ZigBee technology Using radio dimmer and radio scenario control actuators, with the Zigbee technology it is possible to set light scenarios depending on the desired ambiance (e.g. relax, reading, watching TV, night).

    The radio scenario control is capable of saving up to 4 scenarios maximum. Scenarios can also be recalled using a remote control.

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    DEVICE OPERATION DESCRIPTION

    Studio

    Kitchen Bedroom

    Living Room

    HallwayBathroom

    Second bathroom Child

    bedroom

    WWW.BTICINO.COM

  • 44

    DescriptionPower supply/ frequency

    Incandescence lamps

    Halogen lamps

    Ferromagnetic lamps

    Electronic transformers

    Radio actuator DIMMER

    230 Vac@50/60 HzMAX 300 W MIN 60 W

    MAX 300 W MIN 60 W

    MAX 300 W MIN 60 W

    MAX 300 W MIN 60 W

    110 Vac@50/60 HzMax 150 WMin 60 W

    Max 150 WMin 60 W

    Max 150 WMin 60 W

    Max 150 WMin 60 W

    PROCEDURE:

    1. Remove any key covers present.

    2. Select the actuator device that will act as a Coordinator,

    and press the corresponding NETWORK KEY for 4

    seconds.

    The Configuration of radio ZigBee devices is performed in three stages:

    1. Selection of the coordinator device and network

    creation. The coordinator device MUST be connected

    to the electric power line.

    2. Adding the devices to the network.

    3. Association of the devices.

    1 - Selection of the coordinator device and network creation.

    This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

    To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.

    3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.

    4. Create the network by setting the devices that will be included, as indicated in the following page.

    LEARNING indicator LED

    NETWORK indicator LED

    LEDS AND PUSHBUTTONS REQUIRED FOR THE CONFIGURATION

    NETWORK pushbutton

    LEARNING pushbutton

    ON/OFF control key

    Coordinator

    Coordinator

    LOADS WHICH CAN BE DRIVEN

    CONFIGURATION OF THE DEVICES

    LED STATUS

    OFF

    ON STEADY

    FLASHING SLOWLY (1s)

    FLASHING QUICKLY (0.25s)

    FLASHING (60ms)

    FLASHING 3 TIMES (3s)

    4 s

  • A PL

    THE SOLUTIONS 45

    To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,

    2. Repeat the above procedure for all devices to include in the network.

    3. To complete the procedure press the NETWORK KEY of the Coordinator device; The corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.

    while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.

    2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.

    The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.

    3 s CoordinatorDevice

    Device

    CHECKING THE DEVICES BELONGING TO THE NETWORK

    Device Coordinator Device Device

    WWW.BTICINO.COM

  • 100 %

    46

    1. If fitted, remove the key covers of the involved devices.

    2. Press the LEARNING KEY of the SCENARIO CONTROL, the lEARNING LED (green) will flash slowly.

    Procedure:

    4. Press the LEARNING KEY of the first DIMMER ACTUATOR. The LEARNING LED (green) will flash slowly.

    5. Press the ON KEY (bottom left) of the first DIMMER ACTUATOR. THE LEARNING LED (green) will start flashing quickly.

    The scenario consists of the simultaneous activation of several loads, with the objective of creating a specific comfort situation. As an example, below is a description of the procedure for creating a scenario for switching ON two dimmer light points, one at 50% and one at 100% of its power.

    Configuration of the scenario functions

    3. Press KEY 1; the LEARNING LED (green) will start flashing quickly.

    6. Press the LEARNING KEY of the second Dimmer actuator. The LEARNING LED (green) will flash slowly.

    7. Press the ON KEY (bottom left) of the second Dimmer actuator. The LEARNING LED (green) will start flashing quickly.

    Scenario control

    Scenario control

    Dimmer actuator

    100 %

  • 50 %

    THE SOLUTIONS 47

    9. Press the LEARNING KEY of the SCENARIO CONTROL. The LEARNING KEY (green) of the DIMMER ACTUATORS and of the SCENARIO CONTROL will switch off.

    10. Check that the scenario has been programmed correctly by switching all the lights off and pressing pushbutton no. 1 of the SCENARIO CONTROL. If correctly set, the lights will switch on at the level set during the configuration procedure.

    8. Press and hold down the KEY (bottom right) until the desired brightness value has been reached (e.g. 50%). The LEARNING LED (green) will start flashing quickly.

    Scenario controlDimmer actuator 1

    Dimmer actuator 2

    WWW.BTICINO.COM

  • L L L

    1 1 1

    !"

    48

    FUNCTIONAL DIAGRAM

    LIST OF DEVICES THAT MUST BE ORDERED

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    1 Radio actuator DIMMER 3 LN4593 H4593573816 573817

    67237

    2 Radio scenario control 1N4589N (round cover plate)L4589N (square cover plate)

    HA4589 (square cover plate)HB4589 (round cover plate)

    573848 573849

    67240

    3 Radio remote control 1 3528N 3528N 573870 573870

    1 module light actuator key cover DIMMER symbol

    3N4911AINNT4911AINL4911AIN

    HD4911AI HC4911AI HS4911AI

    supplied68265 68565

    1 module light actuator key cover NEUTRAL

    3N4915NNT4915NL4915N

    HD4915BAHC4915BAHS4915BA

    supplied68081 68381

    1 module scenario control key cover

    2N4911N NT4911N L4911N

    HD4911 HC4911 HS4911

    supplied68081 68381

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

    Flush mounted radio actuator dimmer

    Flush mounted radio actuator dimmer

    Flush mounted radio actuator dimmer

    Radio scenario controlRadio remote control

  • LON

    OFF

    N

    L

    TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    N

    L

    TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    THE SOLUTIONS 49

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    Maximum distancesThe maximum distance between 2 devices is:150 metres on free field.

    15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

    Radio light actuator

    Radio light actuator

    Radio control

    Radio light actuator

    Junction box

    Radio scenario control

    150 metres

    15 metres

    Wall

    110

    1)

    WWW.BTICINO.COM

  • 50

    Solution for the addition of a light point with ZigBee technologyThe Zigbee technology gives the possibility of adding a light point to manage the lighting of the room. The traditional switch is replaced by a radio actuator.

    The new light point consists of a radio control surface mounted on the wall.

    Radio actuator 230 Vac cableLampRadio control

    Legend of symbols:

    Distribution board

    DEVICE OPERATION DESCRIPTION

    ON/OFF radio actuator for light control:for the local control of lamps and loads

    Radio control:for ON/OFF control of a group of radio actuators. Blank

    plateON/OFF pushbutton

    Studio

    Living Room HallwayBathroom

    Kitchen

    Second bathroom

    Child bedroom

    Bedroom

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

  • THE SOLUTIONS 51

    DescriptionPower supply/ frequency

    Incandescence lamps

    Halogen lampsFerromagnetic lamps

    Electronic transformers

    Radio actuator for light automation

    230 Vac@50/60 HzMAX 400 W MIN 60 W

    MAX 400 W MIN 60 W

    MAX 400 W MIN 60 W

    MAX 400 W MIN 60 W

    110 Vac@50/60 HzMax 200 WMin 60 W

    Max 200 WMin 60 W

    Max 200 WMin 60 W

    Max 250 WMin 135 W

    LOADS WHICH CAN BE DRIVEN

    CONFIGURATION OF THE DEVICES

    PROCEDURE:

    1. Remove any key covers present.

    2. Select the actuator device that will act as a Coordinator,

    and press the corresponding NETWORK KEY for 4

    seconds.

    The Configuration of radio ZigBee devices is performed in three stages:

    1. Selection of the coordinator device and network creation. The coordinator device MUST be connected

    to the electric power line.

    2. Adding the devices to the network

    3. Association of the devices

    1 - Selection of the coordinator device and network creation.

    This is the first operation that must be completed after wiring the devices. After its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

    To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.

    3. The NETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.

    LEDS AND PUSHBUTTONS REQUIRED FOR THE CON-FIGURATION

    LED STATUS

    OFF

    ON STEADY

    FLASHING SLOWLY (1s)

    FLASHING QUICKLY (0,25s)

    FLASHING (60ms)

    FLASHING 3 TIMES (3s)

    4. Create the network by setting the devices that will be included, as indicated in the following page.

    Coordinator

    Coordinator

    LEARNING indicator LED

    NETWORK indicator LED

    NETWORK pushbutton

    LEARNING pushbutton

    ON/OFF control key

    4 s

    WWW.BTICINO.COM

  • A PL

    52

    To check the devices belonging to a common network press the NETWORK KEY of any actuator device, or the NETWORK KEY of the Coordinator device: the NETWORK LED (yellow) of the Coordinator device will flash slowly,

    2. Repeat the above procedure for all devices to include in the network.

    3. To complete the procedure press the NETWORK KEY of the Coordinator device; The corresponding NETWORK LED will FLASH THREE TIMES, while the NETWORK LEDs of all other devices will switch off.

    while the NETWORK LEDs (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.

    2 - Adding the devices to the network1. Press the NETWORK KEY of the first device to include.

    The NETWORK LED (yellow) turns on steady during the network search stage. Once the stage has been completed, it will start flashing quickly.

    3 sDevice

    CHECKING THE DEVICES BELONGING TO THE NETWORK

    Device Coordinator Device Device

    Coordinator

    Device

  • A PL

    A PL

    A PL

    A PL

    THE SOLUTIONS 53

    3. Press the ON KEY (bottom right). The LEARNING LED (green) will start flashing quickly.

    NOTE: repeat the procedure described at points 2 and 3 for each command to be associated to the actuator.

    5. Press the ON KEY (bottom right) on the ACTUATOR. The load connected turns on, the LEARNING LED (green) changes FLASHING mode, from slow to quick.

    6. Press the LEARNING KEY on the RADIO CONTROL. The LEARNING LEDS (green) of all associated devices will go off.

    3 - Association of the devices1. If fitted, remove the key covers of the involved devices.

    2. Press the LEARNING KEY of the RADIO CONTROL, the LEARNING LED (green) will flash slowly.

    4. Press the ACTUATOR TO Associate to the LEARNING KEY. The LEARNING LED (green) will start flashing slowly.

    Control

    Control

    Actuator

    Actuator

    Control

    Actuator

    WWW.BTICINO.COM

  • A PL

    L

    1

    2

    54

    7. The devices are now associated: to check that the configuration procedure has been performed correctly press the OFF KEY on the radio control; the load connected to the actuator should go off.

    Otherwise repeat the association procedure described.

    FUNCTIONAL DIAGRAM

    LIST OF DEVICES THAT MUST BE ORDERED

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    1 Light control ON/OFF radio actuator 1 LN4590 H45920573812

    57381367231

    2 Light radio control 1N4596N (round cover plate)

    L4596N (square cover plate)

    HA4596 (square cover plate)

    HB4596 (round cover plate)

    573834

    57383567235

    1 module key cover for actuator and light control 4

    N4915AN

    NT4915AN

    L4915AN

    HD4915BA

    HC4915BA

    HS4915BA

    supplied68110 (right)

    68410 (right)

    Flush mounted ON/OFF radio actuatorRadio light Control

  • LN

    L

    TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    N

    L

    TV/SAT IPTV

    automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

    THE SOLUTIONS 55

    Maximum distancesThe maximum distance between 2 devices is:150 metres on free field.

    15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

    Junction box

    Radio actuator

    Radio control

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    110

    1)

    Radio light actuator

    Radio light actuator

    Radio control

    150 metres

    15 metres

    Wall

    WWW.BTICINO.COM

  • ON

    OFF

    56

    1 Source sound system solution with SCS BUS technologyThe 1 source sound system solution gives the possibility of installing a sound system in the room, with the option of following the favourite music program in each room,

    with high sound quality. The installation is simple, flexible, and fast.

    Flush mounted stereo amplifier:it amplifies the stereo signal on the BUS and drives up to two loudspeakers with impedance between 8 and 16 OHMs. The front of the amplifier includes two pushbuttons, used to switch the loudspeakers on/off (short pressure); adjust the output volume (extended pressure); cycle through the saved radio stations.

    Radio Tuner:its capable of receiving FM radio stations. The front pushbuttons and the backlit display give the possibility of adjusting the device, store radio stations in the memory, display RDS messages and the tuned frequency. The radio is fitted with an internal wire antenna. In case of insufficient signal inside the building, a coaxial type connection may be used. For the programming procedure see the CD supplied with the product.

    Studio

    Living Room

    HallwayBathroom

    Kitchen

    Second bathroom Child

    bedroom

    Bedroom

    Legend of symbols:

    Distribution board

    BUS - SCScable

    Audio cableAmplifier Loudspeaker

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    DEVICE OPERATION DESCRIPTION

    Flush mounted stereo amplifier

    False ceiling mounted loudspeakers:20 W power, diam. 10 cm, springs for easy fastening.

  • PRI

    SCS A-V SCS

    346030

    PRI: 220 - 240V~185-175mA50/60Hz

    SCS A-V 27VdcSCS 600mA

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    BUS

    1 2

    3 3

    4 4

    5

    6

    THE SOLUTIONS 57

    CONFIGURATION OF THE DEVICES

    FUNCTIONAL DIAGRAM

    The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.

    WARNING: the devices must only be configured when the system is not powered.

    NOTE: the reference code for the configurators is sold in kits of 10 pieces

    Description of the confi gurators

    Confi gurator socket

    Confi gurator

    Pull-out handle

    Line terminator

    Amplifier

    230 Vac

    LIVING ROOM BEDROOMLoudspeaker Loudspeaker

    Amplifier

    Mini Power supply

    In/out wiring

    Radio Tuner

    S = 1MEM = 2

    A = 1PF = 1

    A = 1PF = 2

    WWW.BTICINO.COM

  • 58

    LIST OF DEVICES THAT MUST BE ORDERED

    List of flush mounted devices

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    3 Flush mounting amplifier 2 L4562 H4562 573976 67302

    1 module Diffusion functions

    key cover2

    N4911BNF

    NT4911BNF

    L4911BNF

    HD4911BF

    HC4911BF

    HS4911BF

    573966 (right)

    573967 (right)

    68263 (right)

    68563 (right)

    1 module ON-OFF & adjustment

    key cover2

    N4911AIN

    NT4911AIN

    L4911AIN

    HD4911AI

    HC4911AI

    HS4911AI

    573964 (left)

    573965 (left)

    68264 (left)

    68564 (left)

    4 False ceiling mounted loudspeakers 4 L4566/10 L4566/10 573982 573982

    5 BUS - SCS cable 1 336904 336904 573999 573999

    6 Line terminator 1 3499 3499 3589 3589

    Configurator 1 1 3501/1 3501/1 49201 49201

    Configurator 2 1 3501/2 3501/2 49202 49202

    Pull-out handle 1 3502 3502 49265 49265

    Ring 2 - - -68083

    68383

    Description q.ty BTicino Legrand Size(DIN)

    1 Mini Power supply 230 Vac 1 346030 - 2 modules

    1 Mini Power supply 110/127 Vac 1 346031 - 2 modules

    2 Radio Tuner 1 F500N 03582 4 modules

    TOTAL SIZE 6 modules

    List of DIN module devices

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

  • ON

    OFF

    BUSPRI

    035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA

    SCS

    THE SOLUTIONS 59

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    Flush mounted amplifier for the management of the sound source.

    Apartment switchboard

    Power supply and radio tuner

    NOTE 1): recommended height NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

    110

    1)

    Amplifier

    Rear view

    BUS

    Front view

    Mini Power supply

    Vac

    Radio Tuner

    160 1)

    WWW.BTICINO.COM

  • A60

    Quickly press and release the M pushbutton for the selection of the position number where the station will be stored.

    The display shows the position where the station will be saved (A).

    Press the forward/back pushbuttons to tune the radio to the desired frequency.

    When changing the frequency, the number displayed will start flashing, to indicate that the frequency currently displayed is different from the stored frequency.

    Once the desired station has been found, press and hold the M pushbutton until the two LEDs start flashing.

    Release the pushbutton. The radio station has now been saved.

    To save other stations repeat the same procedure.

    The device gives the possibility of storing up to 10 radio stations. As a rule, when the tuner is supplied no radio stations are stored.

    Procedure for storing radio stations

  • ON

    OFF

    THE SOLUTIONS 61

    2 multichannel sources sound system solution with SCS BUS technology

    The 2 multichannel sources sound system solution gives the possibility of installing a sound system in the room, with the option of selecting the favourite sound source,

    and have different music played in different rooms, with high sound quality. The installation is simple, flexible, and fast.

    RCA input:provides interfacing, and the possibility of adapting the level of signal of an external source. The connection with the external source is by means of two female RCA connectors (red = right channel; white = left channel). The knob is used to adjust the sensitivity of the input signal. For optimum adjustment the corresponding LED must flash.

    False ceiling mounted loudspeakers:20 W power, diam. 10 cm, springs for easy fastening.

    Flush mounted stereo amplifier:it amplifies the stereo signal on the BUS and drives up to two loudspeakers with impedance between 8 and 16 OHMs. The front of the amplifier includes two pushbuttons, used to switch the loudspeakers on/off (short pressure); adjust the output volume (extended pressure); switch audio source; cycle through the saved radio stations.

    Radio Tuner:its capable of receiving FM radio stations. The front pushbuttons and the backlit display give the possibility of adjusting the device, store radio stations in the memory, display RDS messages and the tuned frequency. The radio is fitted with an internal wire antenna. In case of insufficient signal inside the building, a coaxial type connection may be used. For the programming procedure see the CD supplied.

    PLANIMETRY FOR THE POSITIONING OF THE DEVICES

    DEVICE OPERATION DESCRIPTION

    Studio

    Living Room

    Hallway

    Bathroom

    Kitchen

    Second bathroom Child

    bedroom

    Bedroom

    Hallway

    Legend of symbols:

    Distribution board

    BUS - SCS cable Audio cableAmplifier RCA input Loudspeaker

    Flush mounted stereo amplifier

    Flush mounting RCA input

    Status notification LED

    Sensitivity LED

    WWW.BTICINO.COM

  • ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    ON

    OFF

    5

    4 4 4

    6 6 6

    12

    3

    78

    BUSON

    OFF

    ON

    OFF

    ON

    OFF

    62

    FUNCTIONAL DIAGRAM

    The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUNCTIONAL DIAGRAM.

    WARNING: the devices must only be configured when the system is not powered.

    NOTE: the reference code for the configurators is sold in kits of 10 pieces

    CONFIGURATION OF THE DEVICES

    Description of the confi gurators

    Confi gurator socket

    Confi gurator

    Pull-out handle

    Multichannel matrix

    RCA input (*)

    Line terminatorLine terminator

    Power supply

    LIVING ROOM/STUDIO BEDROOM

    Loudspeaker

    Radio Tuner

    In/out wiring

    OUT1 OUT2

    WARNING(*): If the sound source connected to the RCA input is not battery powered, the source insulator must be used (item 3495 BTicino, item 573988 Legrand).

    A = 1MEM = 2

    S = 2

    Loudspeaker Loudspeaker

    VacS1 S2 BUS

    A = 1PF = 2

    A = 1PF = 1

    A = 2PF = 1

  • THE SOLUTIONS 63

    LIST OF DEVICES THAT MUST BE ORDERED

    Description q.tyResidential series items

    Livinglight Axolute Arteor Cliane

    4 Flush mounting amplifier 3 L4562 H4562 573976 67302

    1 module Diffusion functions

    key cover3

    N4911BFN

    NT4911BFN

    L4911BFN

    HD4911BF

    HC4911BF

    HS4911BF

    573966 (right)

    573967 (right)

    68263 (right)

    68563 (right)

    Key cover ON-OFF regulation

    1 module3

    N4911AIN

    NT4911AIN

    L4911AIN

    HD4911AI

    HC4911AI

    HS4911AI

    573964 (right)

    573965 (right)

    68264 (right)

    68564 (right)

    5 RCA input 1N4560

    NT4560

    L4560

    HD4560

    HC4560

    HS4560

    573926

    573927

    67301 (dispositivo)

    68261 (cover)

    68561 (cover)

    6 False ceiling mounted loudspeakers 6 L4566/10 L4566/10 573982 573982

    7 BUS - SCS cable 1 336904 336904 573999 573999

    8 Line terminator 2 3499 3499 3589 3589

    Configurator 1 1 3501/1 3501/1 49201 49201Configurator 2 1 3501/2 3501/2 49202 49202Pull-out handle 1 3502 3502 49265 49265

    Ring 3 - - -68083

    68383

    Description q.ty BTicino Legrand Size(DIN)

    1 Power supply 230 Vac 1 346000 63435 8 modules

    1 Power supply 127 Vac 1 346001 573990 8 modules

    2 Multichannel matrix 1 F441M 03584 10 modules

    3 Radio Tuner 1 F500N 03582 4 modules

    TOTAL SIZE 22 modules

    List of flush mounted devices

    List of DIN module devices

    NOTE: - LIVINGLIGHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Cliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

    WWW.BTICINO.COM

  • ON

    OFF

    BUS

    PRI

    035 67PRI: 220 240 V~ 185 175 mA 47/63 HzSCS: 27 Vdc 600 mA

    SCS

    64

    PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

    WIRING AND ACTIVATION OF THE DEVICES

    110

    1)

    Flush mounted amplifier for the management of the sound source and RCA input device.

    Amplifier

    Rear view

    BUS

    160 1)

    Apartment switchboard

    NOTE 1): recommended height

    Power supply, multichannel matrix, and radio FM tuner

    Power supplyMultichannel matrix

    Radio Tuner FM

    S1

  • ATHE SOLUTIONS 65

    Quickly press and release the M pushbutton for the selection of the position number where the station will be stored.

    The display shows the position where the station will be saved (A).

    Press the forward/back pushbuttons to tune the radio to the desired frequency.

    When changing the frequency, the number displayed will start flashing, to indicate that the frequency currently displayed is different from the stored frequency.

    Once the desired station has been found, press and hold the M pushbutton until the two LEDs start flashing.

    Release the pushbutton. The radio station has now been saved.

    To save other stations repeat the same procedure.

    The device gives the possibility of storing up to 10 radio stations. As a rule, when the tuner is supplied no radio stations are stored.

    Procedure for storing radio stations

    WWW.BTICINO.COM

  • Guida alla progettazione e allinstallazione

    GU

    IDA

    TECN

    ICA

    2012

    MH1

    2GT -

    Edizi

    one 0

    1/20

    12BT

    icino

    S.p

    .A. s

    i rise

    rva

    il diri

    tto d

    i var

    iare

    in q

    ualsi

    asi m

    omen

    to i c

    onte

    nuti

    del p

    rese

    nte

    stam

    pato

    e d

    i com

    unica

    re, in

    qua

    lsias

    i form

    a e

    mod

    alit

    , i ca

    mbi

    amen

    ti ap

    porta

    ti.

    BTicino SpAVia Messina, 3820154 Milano - Italiawww.bticino.it

    Per documentazione tecnica e informazioni di carattere commerciale

    ORGANIZZAZIONE DI VENDITA E CONSULENZA TECNICA

    Numero Verde

    800-837035

    Servizio Preventivazione gratuito

    Numero Verde

    800-293000

    Numeri attivi dal luned al venerd dalle 8.30 alle 19.00 e il sabato dalle 8.30 alle 12.30

    1JFNPOUFt7BMMFE"PTUBt-JHVSJBUFFICIO REGIONALE10098 RIVOLI (TO)c/o PRISMA 88 C.so Susa, 242Tel. Q 011/9502611Fax 011/9502666

    -PNCBSEJBUFFICIO REGIONALE20154 MILANO Via Messina, 38Tel. Q 02/3480600Fax 02/3480610

    7FOFUP0DDJEFOUBMFt 5SFOUJOP"MUP"EJHFUFFICIO REGIONALE37047 SAN BONIFACIO (VR)JJ CONSULTING SasLoc. Crosaron Villabella 18c/o SoavecenterTel. 045/7612497Fax 045/6104507

    7FOFUP0SJFOUBMFt 'SJVMJ7FOF[JB(JVMJBUFFICIO REGIONALE35127 CAMIN PADOVAVia Vigonovese, 50Tel. Q 049/8993011Fax 049/8993066

    &NJMJB3PNBHOBt 34.t.BSDIFUFFICIO REGIONALE40069 ZOLA PREDOSA (BO)Via Nannetti, 5/ATel. Q 051/6189911Fax 051/6189999

    UFFICIO REGIONALE60019 SENIGALLIA (AN)Via Corvi, 18Tel. Q 071/668248Fax 071/668192

    "CSV[[Pt.PMJTFt1VHMJBt#BTJMJDBUBUFFICIO REGIONALE70026 MODUGNO (BA)Via Paradiso, 33/GTel. Q 080/5352768Fax 080/5321890

    5PTDBOBt6NCSJBUFFICIO REGIONALE50136 FIRENZEVia Aretina, 265/267Tel. Q 055/6557219Fax 055/6557221

    -B[JPt$BMBCSJBt $BNQBOJBUFFICIO REGIONALE00153 ROMAViale della Piramide Cestia, 1pal. C - 4 piano - int. 15/16Tel. Q 06/5783495Fax 06/5782117

    UFFICIO REGIONALE80040 S. MARIA LA BRUNATORRE DEL GRECO (NA)Via dellIndustria, 22Tel. Q 081/ 8479500 Fax 081/ 8479510

    4JDJMJBUFFICIO REGIONALE95125 CATANIAVia G. Battista Grassi, 17/ATel. Q 095/7178883Fax 095/7179242

    4BSEFHOBUFFICIO REGIONALE09100 CAGLIARI c/o centro Commerciale I MULINIPiano Primo int. 1Via Piero della Francesca, 3Localit Su PlanuTel. Q 070/541356Fax 070/541146

    MY HOME

    MH12GT

    GUIDA TECNICA

    ARTEORProject and installation guide

    Rel

    ease

    07_

    11

    ARTEOR

    ARTEOR

    ARTEOR

    Project and installation guide

    Release 07_11

    Release 07_11

    CLIANEProject and installation guide

    Rel

    ease

    07_

    11

    CLIANECLIANE

    Project and installation guide

    Release 07_11

    Release 07_11

    Release 07_11

    Release 07_11

    Numero Verde

    800-293000XXX-XXXXXX

    TO CU

    STOM

    IZETO TAKE ADVANTAGE OF OUR SERVICES CALL THE TOLL FREE NUMBER

    BTicino provides its customers with technical support and quotation services. The objective is to offer to our customers a competent and fast service, working with alongside them as partners capable of providing answers to their needs, and helping them to select the best solutions for their systems.

    MYHOME AUTOMATIONVIDEO DOOR ENTRY SYSTEM

    Our services

    CONTACT OUR CUSTOMER SUPPORT CENTRES

    BTicino offers technical after sales service through authorised centres. For the conditions of the technical assistance service during the warranty period, the costs (for services not covered by the warranty), and the details of the closest CAT call this toll free number: XXX-XXXXXX or go to the Technical Service section of the Professionals Portal.www.bticino.com

    For more information see our guides.

    66

  • TO CU

    STOM

    IZETRAINING CENTRES

    Attend training courses on BTicino systems and solutions: see the training section of the website.

    WEBSITE

    Always keep up to date thanks to our Professionals Portal: there you will find all the relevant product news, technical sheets, videos, and activities of BTicino.

    SOFTWARE E SERVIZI 67WWW.BTICINO.COM

  • TO CU

    STOM

    IZEB

    Tici

    no S

    pA re

    serv

    es a

    t any

    tim

    e th

    e ri

    ght t

    o m

    odify

    the

    cont

    ents

    of t

    his

    book

    let a

    nd to

    com

    mun

    icat

    e,

    in a

    ny fo

    rm a

    nd m

    odal

    ity, t

    he c

    hang

    es b

    roug

    ht to

    the

    sam

    e.AD

    - E

    XCM

    12SF

    B/U

    K -

    Edi

    tion

    04/2

    012

    BTicino SpAVia Messina, 3820154 Milano - Italiawww.bticino.com