Hollow block and ribbed slabs
-
Upload
mohamed-mohsen -
Category
Technology
-
view
16.198 -
download
32
Transcript of Hollow block and ribbed slabs
![Page 1: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/1.jpg)
1
الرحيم الرحمن الله بسم
![Page 2: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/2.jpg)
2
Under supervision of Dr . Mohamed Nabil
This report has been prepared by : Mohamed Mohsen Mohamed Hussein Mohamed Nabil Ali Kamel Mohamed Youssef Mahmoud Youssef Ahmed Hamdy Mohamed Hassan
Hollow block & Ribbed slabs
![Page 3: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/3.jpg)
Outlines
■ Introduction.
■ Comparison between different codes.
■ Solved example by different codes.
■ One & two way slab solved example.
■ Effect of cross ribs on deflection.
■ Modeling.
■ Case study.
3
![Page 4: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/4.jpg)
Introduction
Hollow block and Ribbed slabs are formed by placing blocks on the slab
and concrete ribs.
In case of hollow block slab voided blocks are placed to reduce the total
weight of the slab .
In case of ribbed slab the blocks are not permanent.
The blocks are considered as non-structural element as they do not
contribute to strength of the slab.
Blocks may be made concrete with lightweight aggregate or other material
as polystyrene ( foam ).
Types hollow block slab are one way and two way slabs .
4
![Page 5: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/5.jpg)
Introduction
The advantages of Ribbed and Hollow block slabs are as follows:
■ They provide an economical, versatile lightweight monolithic slab system and
this its main advantage reduction of weight by removing the part of the concrete
below the neutral axis.
■ Components are relatively light and no mechanical handling is necessary there
is ease of construction.
Economic for spans more than 5m with light or moderate live loads, such as hospitals, office or residential buildings.
5
![Page 6: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/6.jpg)
ACI 318 ECP 203
BS 8110 Euro code 2
Comparison between different codes
6
![Page 7: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/7.jpg)
7
■ Net distance between ribs "e" shall not exceed 700 mm.
■ Web width "b" shall not be less than 100 mm or one the third of
depth "t", whichever is greater.
■ Compression slab thickness "ts" shall not be less than 50 mm or one Tenth 1/10 of distance "e", whichever is greater.
Comparison between different codes
Egyptian code (ECP 203)
Limitations of Hollow block slabs :
![Page 8: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/8.jpg)
8
■ The minimum value of rib width (b) isn't less than 1/4 slab thickness
(t) or 100 mm whichever greater, with taking into account
requirements of concrete cover, distance between bars and fire
requirements
Egyptian code (ECP 203)
■ Distance between ribs axes can be increased up to 1.5 m .
■ Thickness of upper slab is determined by a value not less than e/12 or
50 mm whichever greater.
Limitations of Ribbed slabs:
![Page 9: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/9.jpg)
9
Comparison between different codes
British code (BS 8110)
Limitations of Hollow block slabs :
■ Clear distance between ribs (e) not more than 500 mm , jointed in cement : sand mortar ts is 25 mm.
■ Clear distance between ribs (e) not more than 500 mm not jointed in cement : sand mortar ts is 30 mm.
■ All other slabs with permanent blocks ts is 40 or one-tenth 1/10 of clear distance between ribs, whichever is great
Limitations of Ribbed slabs: Clear distance between ribs not more than 1.5 m ts is 50 mm or one-
tenth of clear distance between ribs, whichever is greater.
t b
e
b
t
b ≤ t/4
![Page 10: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/10.jpg)
Euro code (En2)
■ The rib spacing does not exceed 1500 mm.
■ The depth of the rib below the flange does not exceed 4 times its width.
■ The depth of the flange is at least 1/10 of the clear distance between ribs or 50 mm, whichever is the greater.
■ Transverse ribs are provided at a clear spacing not exceeding 10 times the overall depth of the slab.
10
Comparison between different codes
Limitations of Hollow block slabs :
Limitations of Ribbed slabs:
■ One limitation will change from ribbed slab The minimum flange thickness of 50 mm may be reduced to 40 mm.
![Page 11: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/11.jpg)
11
American Concrete Institute (ACI)
■ When permanent filling material having a unit compressive strength at least equal to fc′ in the joists are used ts
shall be not less than 1/12 the clear distance between ribs, nor less than 40 mm.
■ Otherwise ts is not to be less than 1/12 the clear distance between ribs, nor less than 5.0 cm
■ Ribs are not to be less than 10 cm in width, and a depth of not more than 3.5 times the minimum web width.
■ Clear spacing between ribs is not to exceed 75.0 cm
Comparison between different codes
Limitations of Hollow block slabs & Ribbed slab:
![Page 12: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/12.jpg)
12
Code
Limits
Egyptian code British code Euro code American code
Simply sup. L/20 L/20
-----------
L/16
1 end cont. L/25 L/20.8 L/18.5
2 end cont. L/28 ----- L/21
cantilever L/8 L/5.6 L/8
ts ≥ ts ≥ ts ≥ ts ≥
e e ≤ 700 mm e ≤ 1500 mm e ≤ 1500 mm e ≤ 750 mm
b b ≥ b ≤ t/4 b ≤ t/4 b ≥ 100 mm
Cross ribs
L.L ≤ 3 KN/m2 , Ls >
5
L.L > 3 KN/m2
, Ls →(4:7)
L.L > 7m.
------- If L ≥ 10 th.b -------
One X rib One X rib 3 X ribs
Comparison between different codes
![Page 13: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/13.jpg)
13
( 5 m * 7m )
USING ECP
USING BS
USING EURO CODE
USINGACI
( 7m * 7m )
AS ONE WAY HOLLOW
BLOCK SLAB
AS TWO WAY HOLLOW
BLOCK SLAB
![Page 14: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/14.jpg)
14
Fcu= 25 N/mm2
Fy= 360 N/mm2
F.C= 1.5 KN/m2
L.L= 3.0 KN/m2
Solved examples by different codes
![Page 15: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/15.jpg)
15
Code
prop.Egyptian code British code Euro code American code
th.b 250 mm 250 mm 250 mm 300
tS 50 mm 50 mm 50 mm 50 mm
h 200 200 200 250
Mu (Kn.m/rib)19.187 19.187 17.75 23.5
AS 293.30 mm2 255.72 mm2 322.005 mm2 226.67 mm2
Main ribs dim. 100 × 200 mm 100 × 200 mm 100 × 200 mm 100 × 250 mm
Cross ribs No cross ribs No cross ribs One cross rib No cross ribs
Solid partShort dir. long dir. Short dir. long dir. Short dir. long dir. Short dir. long dir.
0.3 m. 0.3 m. 0.3 m. 0.3 m. 0.25 m. 0.3 m. 0.3 m. 0.3 m.
Conc. Quantities
2.806 m3 2.806 m3 2.934 m3 3.07 m3
Solved examples by different codes
![Page 16: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/16.jpg)
16
One & two way slab Solved examples
One way slab
Two way slab
Fcu= 25 N/mm2
Fy= 360 N/mm2
F.C= 1.5 KN/m2
L.L= 3.0 KN/m2
![Page 17: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/17.jpg)
17
SLAB TYPE
PROP.
One way hollow blocks slab Two way hollow blocks slab
th.b. 320 mm 250 mm
h 250 mm 200 mmts 70 mm 50 mm
Mu (KN.m/rib) 45.64 α dir. β dir.
15.68 15.68
As 529.255 mm2/ rib 239.68 mm2/ rib. For α dir.And 251.09 mm2/ rib. for β dir.
Ribs dim. 0.12 * 0.25 m 0.1 * 0.2 m
NO. of main ribs 11 12No. of cross ribs 1 12Conc. quantities 5.6854 m3 5.234 m3
RFT 1017.79 mm2 /m 981.54 mm2/m
One & two way slab Solved examples
It is obvious that the RFT and concrete quantities in the two way hollow block slab is more economic however the execution of the two way hollow block slab is harder than the one way hollow block slab.
![Page 18: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/18.jpg)
Effect of cross ribs on deflection
In The previous example the effect of cross ribs on deflection will be
discussed on sap program.
At first one cross rib is put in the mid span of the slab.
Then two cross ribs are put at 1/3 of the span from each side.
18
![Page 19: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/19.jpg)
19
■ Case of one cross rib:
Effect of cross ribs
![Page 20: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/20.jpg)
20
■ Case of two cross rib:
Effect of cross ribs
The two cases have the same deflection value so it is more economic to use one cross rib at mid span
![Page 21: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/21.jpg)
Modeling Introduction Different models of hollow block slabs on computer programs (Sap 2000) are illustrated.
The Example:
F.C =1.5 KN/m2 ,
L.L =3 KN /m2 ,
Block weight = 160 N
Number of blocks is 22 in short direction and 13 in the long direction.
Weight of the blocks on the slab == 1.3 kN/m2.
Wrib = 6.145 (KN/(1.0*s m2).
Number of ribs in the long direction = 12 rib
21
![Page 22: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/22.jpg)
22
Modeling ■ Model 1
The ribs are frame elements with cross section as T-section and connected
together with a virtual slab with very small thickness.
![Page 23: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/23.jpg)
23
The moment on the ribs=19.3675 KN.m
![Page 24: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/24.jpg)
24
Modeling ■ Model 2
The ribs are frame elements with cross section as T-section and connected
together with frame elements with cross section as rectangular section .
The moment on the ribs= 19.1793 KN.m
![Page 25: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/25.jpg)
25
Modeling ■ Model 3
The ribs are converted to a thickness on the whole slab and use virtual slab
to connect between elements with very small thickness.
![Page 26: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/26.jpg)
26
The moment on the ribs= 19.0767 KN.m
![Page 27: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/27.jpg)
27
Modeling ■ Model 4
The ribs are represented as frame elements with rectangle section and the
connecting element is frame element with rectangle section.
The moment on the ribs= 19.1555 KN.m
![Page 28: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/28.jpg)
This table shows the differences between the models and the manual solution .
28
Manual 4 3 2 1 Model
19.1875 19.1555 19.0767 19.1793 19.3675 M (ultimate)KN .m
Rectangular section
Rectangular section
T-section T-section Cross section of ribs
Frames Virtual slab Frames Virtual slab Connecting elements
W (rib) On slab W (rib) On slab Loads
0 1 0 1 Self weight multiplier
Modeling
![Page 29: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/29.jpg)
Case study
Introduction: Different case study for hollow block slabs and ribbed slabs.■ Case 1
29Ordinary one way hollow block slab
![Page 30: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/30.jpg)
30
Case study
![Page 31: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/31.jpg)
.
31
Case study
■ Case 2
Cantilever hollow block slabs
![Page 32: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/32.jpg)
32
Case study
■ Case 3
Two way hollow block slabs
![Page 33: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/33.jpg)
Ribbed slabs one way and two way ( waffle ) and how the blocks are placed .
33
Case study
■ Case 4
![Page 34: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/34.jpg)
34
Case study
![Page 35: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/35.jpg)
35
Case study
■ Case 5
In this case foam blocks are used
![Page 36: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/36.jpg)
Clay blocks are used in this case.
36
Case study
■ Case 6
![Page 37: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/37.jpg)
Questions
37
![Page 38: Hollow block and ribbed slabs](https://reader034.fdocuments.us/reader034/viewer/2022052122/556d1c9dd8b42a540c8b4af1/html5/thumbnails/38.jpg)
38