Hmt Lab Manual2013

download Hmt Lab Manual2013

of 37

Transcript of Hmt Lab Manual2013

  • 7/26/2019 Hmt Lab Manual2013

    1/37

    THERMAL ENGINEERING LAB II

    LIST OF EXPERIMENTS

    HEAT TRANSFER

    1. Thermal conductivity measurement by guarded plate method

    2. Thermal conductivity of pipe insulation using lagged pipe apparatus

    3. Natural convection heat transfer from a vertical cylinder

    4. Forced convection inside tube

    5. Heat transfer from pin-fin (natural & forced convection modes)

    6. Determination of Stefan-Boltzmann constant

    7. Determination of emissivity of a grey surface

    8. Effectiveness of Parallel/counter flow heat exchanger

    REFRIGERATION AND AIR CONDITIONING

    1. Determination of COP of a refrigeration system

    2. Experiments on air-conditioning system

    3. Performance test on single/two stage reciprocating air compressor.

  • 7/26/2019 Hmt Lab Manual2013

    2/37

    Expt. No : Thermal conductivity measurement by guarded

    plate methodDate :

    AIM:

    To measure the thermal conductivity of the specimen using guarded plate apparatus.PROCEDURE:1.

    Before start the experiment check the electrical supply and water supply.2. Switch on the power supply and set the heater input to desire value.3. Wait till the steady state temperature is reached.

    4. Note down the following readings5.

    Ammeter reading

    6.

    Voltmeter reading7. Temperature at various points8. Vary the heater input to increase the temperature.

    9. Wait till the steady state temperature is reached.

    10.

    Note down the procedure at different temperature.11.

    After complete the readings calculate the thermal conductivity of the specimen.

    SPECIFICATION:Material : Copper

    Diameter : 125 mmThickness : 3 mm

    Guarded plate:Material : copperInner diameter : 140 mm

    Outer diameter : 200 mmThickness : 3 mm

    Specimen Plate:Material : WoodDiameter : 200 mm

    Thickness : 6 mmWater Bath:

    Material : Mild steelDiameter : 200 mmHeight : 50 mm

    Thermocouple:Type : J Range : 1000 C

    TABULATION

    SI.NOVoltage

    (v)

    Current

    (amps)

    Temperature of circular

    plate(C)

    Avg.temp

    Tc(C)

    Temperature of

    specimen(C)

    Avg.temp

    Ts(C)

    T1 T2 T3 T4 T5 T6

  • 7/26/2019 Hmt Lab Manual2013

    3/37

    FORMULA:Power Input

    Q=V A (W) (Since heat flows on either side of the heater)2

    Where,

    V = voltage in voltsA = Current in Amps

    SKETCH OF GAURDED PLATE SETUP

    (TC-TS) C

  • 7/26/2019 Hmt Lab Manual2013

    4/37

    CALCULATION

    RESULT:

    Thus the thermal conductivity of the specimen is calculated.

  • 7/26/2019 Hmt Lab Manual2013

    5/37

    Expt. No :

    Date :

    THERMAL CONDUCTIVITY OF PIPE INSULATION

    USING LAGGED PIPE APPARATUS

    AIM

    To conduct calculate the thermal conductivity of saw dust using lagged pipe

    apparatus.

    PROCEDURE:

    1. Before switch on the supply check the electrical supply and set the heaterregulator in

    2. minimum position.

    3.

    Switch on the electrical supply and varry the heater regulator to supplyvoltage to the

    4. heater.5. Wait till the steady temperature is reached.

    6.Note down the following readings.a. Ammeter reading

    b. Voltmeter readingc. Temperature at various points

    7. Vary the heater regulator to increase the temperature8. Wait till the steady state temperature is reached

    9.

    Note the above mentioned readings10.Repeat the procedure at different temperature.

    11.Calculate the thermal conductivity of saw dust.

    SPECIFICATION:

    Heater:Type : Rod

    Diameter : 20 mmLength : 500 mmInput : 230 V AC

    Asbestos lagging:Inner Diameter : 20 mm

    Outer Diameter : 80 mmThermocouple:Type : J

    Range : 1000 C

  • 7/26/2019 Hmt Lab Manual2013

    6/37

    Cut section of Lagged pipe

    T7T8

  • 7/26/2019 Hmt Lab Manual2013

    7/37

    CALCULATION

  • 7/26/2019 Hmt Lab Manual2013

    8/37

    RESULT:Thus thermal conductivity of saw dust is calculated using lagged pipe apparatus.

  • 7/26/2019 Hmt Lab Manual2013

    9/37

    Expt. No :

    Date :

    Natural convection heat transfer from a vertical cylinder

    AIM:

    To determine the convective heat transfer coefficient for a heated vertical cylinder innatural convection.PRACTICAL RELEVANCE:

    Free or natural convection is the principal mode of heat transfer from transmissionlines, pipes, refrigerating coils, hot radiators, buildings and many other practical situat ions in

    everyday life.

    PROCEDURE:1.

    Note down the specification of all the instruments provided on the panel and also the

    length (L) and diameter (D) of the metallic tube.

    2.Switch on the heater and heater and adjust the heating rate to a suitable level (VI).

    3.

    Wait for some time to ensure the unit to reach steady state.

    4.

    At steady state record the voltage and current readings and the temperature T 4

    through T6

    5.Repeat the experiment for a different heat rate.

    SKETCH OF NATURAL CONVECTION ARRANGEMENT

    T6

    T5

    T4

    T3

    T2

    T1

  • 7/26/2019 Hmt Lab Manual2013

    10/37

    TABULATION

    S.noVolts

    (v)Current(amps)

    Temperature along thecylinder

    Avg.Temp ofcylinder

    TC (C)

    Temperature of air

    Avg.Tempof air

    Ta (C) T2(C)

    T3(C)

    T4(C)

    T5(C)

    T1(C)

    T6(C)

    FORMULA USED:

    (i) Experimental

    Q=hAT

    A= dl

    Q=VI

    Where,

    Q = Heat transfer rate, W

    A = Area of heat transfer, m2

    h = convective heat transfer coefficient, W/m2

    Cd = diameter of vertical cylinder, mm

    l = length of vertical cylinder, mm

    T = temperature difference(Tc-Ta)

    V = Voltage, volts

    I = Current, Amps.

    (ii) TheoreticalNu=h1/K

    Gr = g 13

    T/2

    Where,Nu = Nusselt number

    K = Thermal conductivity, W/mKGr = Grasiffs number

    g = Acceleratin due to gravity. m/s2

    = coefficient of expansion

    = Kinematic viscosity

  • 7/26/2019 Hmt Lab Manual2013

    11/37

    CALCULATION

    RESULTThus the convection heat transfer coefficient of heated vertical cylinder is

    h = W/m

    2

    K (By experimental)h = W/m2 K (By Theoretical)

  • 7/26/2019 Hmt Lab Manual2013

    12/37

    Expt. No :Date :

    FORCED CONVECTION INSIDE TUBE

    AIM:

    To measure heat transfer co-efficient using forced convection method.

    PROCEDURE:1. Check electrical supply before start the experiment2. Set the heater input to zero position and then switch on the power supply3. Set the air supply to desire level then set the heater input to desire level

    4. Wait till the steady state temperature is reached5. Note the following readings

    * Amps rating in ammeter* Voltage in voltmeter* Temperature at various point using temperature indicator

    * Manometer reading6. Repeat the procedure at different heater input.

    7. After complete the reading calculate the heat transfer co - efficient.

    SPECIFICATION:

    BlowerPower - 420 wattsSpeed - 2800 rpm

    HeaterType - Coil

    Power - 500 W

    OrificeInlet dia - 40 mm

    Orifice dia - 20 mmCopper tube

    Diameter - 53 mmLength - 500 mm

    SKETCH OF FORCED CONVECTON SET UP

  • 7/26/2019 Hmt Lab Manual2013

    13/37

  • 7/26/2019 Hmt Lab Manual2013

    14/37

    CALCULATION

  • 7/26/2019 Hmt Lab Manual2013

    15/37

    RESULT:Thus the heat transfer co-efficient is measured by using the forced convection method.

  • 7/26/2019 Hmt Lab Manual2013

    16/37

    Expt. No :

    Date :

    Heat transfer from pin-fin (natural & forced convection

    modes)AIM:

    To determine the fin efficiency using pin - fin apparatus.PROCEDURE:1.

    Check the electrical supply and then set the heater input as zero.2. Switch on the power supply and run the blower at minimum speed.3. Set the heater input at desire position.

    4. Wait till the steady state temperature is reached.5.

    Now note down the following readings.

    6.

    Temperature at various point using temperature indicator.7. Water level on U - tube manometer.8. Ammeter reading.

    9. Voltmeter reading.

    10.

    Increase the heat supplied by heater using regulator.11.

    Wait till the steady state temperature is reached.12.Note the above mentioned readings.13.Repeat the procedure at different temperature.

    14.After complete the reading calculate the efficient of the fin.SPECIFICATION:Pin - Fin:

    Material : BrassLength : 145 mm

    Diameter : 12 mmDistance between

    each thermocouple : 20 mmDuct:Width : 150 mm

    Height : 100 mmOrifice meter:Inlet diameter : 40 mm

    Orifice diameter : 20 mmOutlet diameter : 40 mm

    Thermocouple:Type : JRange : 1000

  • 7/26/2019 Hmt Lab Manual2013

    17/37

  • 7/26/2019 Hmt Lab Manual2013

    18/37

    RESULT:Thus the efficiency of the fin is calculated using pin - fin apparatus.

    Type of convection Efficiency Effectiveness

    Natural

    Forced

  • 7/26/2019 Hmt Lab Manual2013

    19/37

    Expt. No :

    Date :

    DETERMINATION OF STEFAN-BOLTZMANN

    CONSTANT

    AIM:To calculate the stefan Boltzman constant using stefan - Boltzman apparatus.

    PROCEDURE:1. Check the electrical supply and water supply.

    2. Supply the water to the heater and then switch on the heater.3.

    open the bottom plate of the hemisphere.

    4.

    Wait till the steady state temperature is reached.5. Now colse the bottom plate of the hemisphere and switch on the buzzer.6. Note sown the temperature at various points.

    7. Each time buzzer on note down the temperature at various points.

    8.

    When bottom plate reaches steady state temperature complete the reading.9.

    Draw the graph between time and temperature of the bottom plate find slope dT/dt.10.After complete the reading find stefan boltzman constant.

    SPECIFICATION:Hemisphere:Material : Aluminimum

    Inner diameter : 140 mmOuter diameter : 200 mm

    Water Heater:Power : 3 kW

    Capacity : 1 literInput : 230 V ACThermocouple :

    Type : JRange : 1000 CSmall Plate:

    Material : DigitalInner diameter : 140 mm

    Outer diameter : 200 mm

    SKETCH OF STEFAN BOLTZMAN APPARATUS

    Hot waterline

  • 7/26/2019 Hmt Lab Manual2013

    20/37

    TABULATIONSI.NO Hemisphere

    Temperature

    (C)

    Avg Temp ofHemisphere

    (C) Th

    Bottom platetemperature

    (C) T4

    Steady statetemperature of

    plate Tp

    T1 T2 T3

  • 7/26/2019 Hmt Lab Manual2013

    21/37

    CALCULATION

    GRAPH:Time Vs temperature.

    RESULT:Thus stefan Boltzman constant is find using stefan apparatus.

  • 7/26/2019 Hmt Lab Manual2013

    22/37

    Expt. No :

    Date :

    DETERMINATION OF EMISSIVITY OF A GREY SURFACEAIM:To measurement the emissivity of the test plate using emissivity measurement apparatus.

    PROCEDURE:

    1.

    Before start the experiment check the power supply.2. Set the heater regulator in minimum position and then switch on the power supply.3. Wait till steady state temperature reached.

    4. Note down the following readings5.

    Voltmeter reading6. Ammeter reading

    7. Temperature on each thermocouple point.8. Now increase the supply to the heater by using regulator.

    9. Wait till the steady state temperature is reached.10.Note down the above mentioned readings.11.Repeat the procedure at different temperature.

    12.

    Calculate the emissitivity of test plateSPECIFICATION:

    Black plate:Material : AluminiumDiameter : 150 mm

    Thickness : 3 mmTest plate:

    Material : AluminiumDiameter : 150 mmThickness : 3 mm

    Heater:Type : Coil

    Input : 230 V ACThermocouple:Type : J

    Range : 500 CAmmeter:

    Type : DigitalRange : 0 - 2 AVoltmeter:

    Type : Digital

    Range : 0 - 300 V AC

  • 7/26/2019 Hmt Lab Manual2013

    23/37

    S.NO

    Voltmeter

    (V)

    Ammeter

    (A)

    Test p lateTemperature

    (C)

    Avg.temp

    (C)(Tp)

    Chambertemp

    (C)

    (T4)

    Test plateTemperature(Tb)

    (C)

    Avg.temp

    (C)(Tb)

    Emissivityof test

    plate()T1 T2 T3 T5 T6 T7

    Formula:

    Emissivity of test plate

    Formula used:Tb

    4-T

    4

    s=Tp

    4-T

    4

    Where,

    s = Emissivity of test surfacesTb = Means temperature black surfaceTp = Means temperature polished surface

    T = Ambient temperature T4

    CALCULATION

  • 7/26/2019 Hmt Lab Manual2013

    24/37

    RESULT:Thus the emissivity of the test plate is measured using emiss ivity measurement apparatus.

  • 7/26/2019 Hmt Lab Manual2013

    25/37

    Expt. No :

    Date :

    EFFECTIVENESS OF PARALLEL/COUNTER FLOW

    HEAT EXCHANGER

    Experiment - 1:AIM:To calculate heat transfer co-efficient in parallel flow heat exchanger.

    PROCEDURE:1. Check electrical supply and water supply.2. Set the heater input to zero position.3. Supply water to hot water pipe and cold water pipe.

    4. Open valve2 and valve 4 then close valve1, and valve 3.5. Set the heater input to desire level.

    6. Wait till the steady state temperature condition.7. Note the following reading

    * Flow rate of hot water and cold water.

    * Temperature displayed in temperature indicator.* Ammeter reading

    * Voltmeter reading.8. Repeat the procedure at different heater input.9. After complete the reading calculate the heat transfer co-efficient.

    Hot Water Tube:Length : 1210 mmDiameter : 28 mm

    Cold water Tube

    Length : 1210 mmDiameter:18mm

  • 7/26/2019 Hmt Lab Manual2013

    26/37

    Mean Temperature of Hot WaterMean Temperature of cold

    Water

    Mass flow rate of hot water

    V h = Volume of hot water in liters

    t h= Time taken in hour

    h = Density of water at T h [from Data book] kg/m3

    Mass flow rate of cold water

    Vc = Volume of cold water in litres

    tc = Time taken in hour

    c = Density of water at Tc [from Data book] kg/m3

  • 7/26/2019 Hmt Lab Manual2013

    27/37

    CALCULATION

  • 7/26/2019 Hmt Lab Manual2013

    28/37

    RESULT:

    Thus heat transfer co-efficient is calculated in parallel flow heat exchanger.

    Experiment - 2:

    AIM:To calculate heat transfer co-efficient in counter flow heat exchanger.

    PROCEDURE:1. Check electrical supply and water supply.2. Set the heater input to zero position.

    3. Supply water to hot water pipe and cold water pipe.4. Open valve1 and valve 3 then close valve2, and valve 4.

    5. Set the heater input to desire level.6. Wait till the steady state temperature condition.7. Note the following reading

    * Flow rate of hot water and cold water.* temperature displayed in temperature indicator.

    * Ammeter reading* Voltmeter reading.

    8. Repeat the procedure at different heater input.

    9. After complete the reading calculate the heat transfer co-efficient.

  • 7/26/2019 Hmt Lab Manual2013

    29/37

    Mass flow rate of hot water

    Vh = Volume of hot water in litersth= Time taken in hour

    h= Density of water at Th [from Data book] kg/m3

  • 7/26/2019 Hmt Lab Manual2013

    30/37

  • 7/26/2019 Hmt Lab Manual2013

    31/37

    CALCULATION

    RESULT:

    Thus heat transfer co-efficient is calculated in counter flow heat exchanger.

  • 7/26/2019 Hmt Lab Manual2013

    32/37

    Expt. No :

    Date :

    DETERMINATION OF COP OF A REFRIGERATION

    SYSTEMAIM :

    To measure COP of the vapor compression refrigeration system.PROCEDURE1. Check the electrical supply and pour water to the evaporator to desire level.2. Switch on the power supply.3. Allow refrigerant to flow through thermo expansion valve or capillary tube.

    4. Set the flow to desire level and wait till the steady state temperature is reached.5. Note the following readings.

    * Temperature at various points* Pressure indicated on pressure gauge* Power consumption by compressor

    * Power consumption by condenser

    6. Repeat the procedure at different flow rate.7. After complete the read ingcalculateCOP.

  • 7/26/2019 Hmt Lab Manual2013

    33/37

  • 7/26/2019 Hmt Lab Manual2013

    34/37

    CALCULATION:

    RESULT:Thus the cop of the vapor compression refrigeration system is measured.

  • 7/26/2019 Hmt Lab Manual2013

    35/37

    Expt. No :Date :

    EXPERIMENTS ON AIR-CONDITIONING SYSTEM

    AIM:To determine co-efficient of performance of the air conditioning system.

    PROCEDURE:1. Check the electrical supply before start the experiment.

    2. Switch ON the power supply and switch ON the condenser coding coil andcompressor.3. Wait till the steady state temperature.

    4. Note the following reading* Temperature displayed in the indicator.

    * Dry bulb and wet bulb temperature at different location.* Flow rate of refrigerant using rotameter.* Power consumption by the compressor

    * Overall power consumption.* Pressure at different points.

    5. After complete the reading switch OFF the compressor, condenser and cooling coil.6. Now calculate the co-efficient of performance of the air conditioning system.SPECIFICATION:

    Compressor:Type : HermaticCapacity : 2 ton

    Refrigerant : R 134 a

    Condensor:Power : 75 WSpeed : 1350 rpm

    SKETCH OF AIR CONDITIONER TEST RIG

  • 7/26/2019 Hmt Lab Manual2013

    36/37

  • 7/26/2019 Hmt Lab Manual2013

    37/37

    CALCULATION

    RESULT: