High Speed Centrifugal Blower Packages - Gardner Denver
Transcript of High Speed Centrifugal Blower Packages - Gardner Denver
Maintenance Free • Permanent Magnet Motor with oil-less
technology requires no lubrication
• No minimum lift-off speed and near friction-less design ensures no wear and no replacement cost
Active Magnet Technology• Monitors shaft position 15,000 times
per second
• Maintains precise shaft location for optimal efficiency
EfficiEncyEfficiency Delivered
2
DurabilityOne piece impeller is machined from solid billet aluminum providing increased strength and longevity
ReliabilityOne-piece cast aluminum volute with integral fins for increased strength and integrity
EfficiencyProprietary vane profile maintains high efficient operation over a wide range of speeds, allowing for greater turndown
EfficiEncy 3
Protection by Design
robust design
precise monitoring
oil-less technology
maintenance free
unmatched performance
energy efficiency
peace of mind
Controller is…Simple
• Easy to operate touchscreen interface
• Provides trending data for reporting
Smart
• Continuously monitors machine performance
• Monitors and records advisory faults and shutdowns
Flexible
• Able to sequence up to eight machines for more balanced run time
• Variable frequency drive allows pin-point operational accuracy
• SCADA compatible for easy system integration
Advanced
• Calculates exact moment to moment surge line
• Corrects performance as conditions draw closer to surge line
4
Surge: [surj] nounThe point at which centrifugal machines cannot overcome the system resistance or backpressure
Excessive surge conditions in centrifugal machines can cause package failure
Smart controls prevent surge conditions• During normal operation, the IQ-HS
controller provides constant monitoring of all variables
• Controller continuously calculates the exact surge line and intervenes once the performance threshold has been crossed
Surge Line
Controlle
r Interve
ntion
Normal Operation
Flow
Pres
sure
Surge Condition
5
Package Attributes
1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000
0
5
10
15
20
25
HS-400
1,699 3,398 5,097 6,796 8,495 10,194 11,893 13,592 15,291 16,990
0
34
69
103
138
172
SPres
su
re
(Ps
ig)
FLOW (CFM)
Barometer 14.696 PSIA, Inlet Temperature 68 Deg F, 36% Relative Humidity
FLOW (m3⁄h)
Pres
su
re
(kPa
g)
Quiet Enclosure Provides ISO certified sound rating below 80 dBA
Easy Open Enclosure Panels Provide easy access to change inlet and enclosure filters
Closed Loop Cooling System Requires no external water source
Top Discharge Piping Allows flexible installation options
6
By The Numbers
Dimensions (in inches)
Section IQ-HS 1 IQ-HS 2 , IQ-HS 3
A 67.4 89.4
B 46.0 46.0
C 100.7 122.7
D 105.4 105.4
E 81.6 81.6
WEIGHT 3,850 lbs 4,440 lbs
E
D
C
A
B
7