High Efficiency, Gas Fired, Stainless Steel, Condensing Boiler Product Data Sheet.pdf• 155 MBH...

2
PREMIUM FEATURES 95% AFUE – High efficiency and low emissions! Six wall hung models; 85, 110, 155, 205, 270 MBH 155 MBH combi model available! – Best-in-class DHW performance Field-proven, stainless steel fire tube heat exchanger Advanced Sage2.2 boiler control provides “out-of-the-box” high performance and easy setup – Ergonomically angled touch screen display simplifies installation, operation, and diagnostics – Easily connects to optional Sage Zone Control for additional energy savings, system optimization, and “short cycle” prevention High altitude – zero or minimal de-ratings, reduces the costs of oversizing, field adjustable FULL SIZE easy access side service panel VALUABLE EXTRAS INCLUDED Versatile top and bottom connections for supply & return (on heating-only boilers) Universal vent connection for CPVC/PVC, polypropylene Split-voltage junction box, fused easy-connect terminals Outdoor reset and sensor (wired) Piped & wired for low water cutoff installation (probe not included) 5-year parts warranty ANYWHERE UNMATCHED ANYWHERE UNMATCHED High Efficiency, Gas Fired, Stainless Steel, Condensing Boiler COMBI AVAILABLE! MADE IN U.S.A.

Transcript of High Efficiency, Gas Fired, Stainless Steel, Condensing Boiler Product Data Sheet.pdf• 155 MBH...

Page 1: High Efficiency, Gas Fired, Stainless Steel, Condensing Boiler Product Data Sheet.pdf• 155 MBH combi model available! – Best-in-class DHW performance • Field-proven, stainless

PREMIUM FEATURES

• 95%AFUE –Highefficiencyandlowemissions!

• Sixwallhungmodels;85,110,155,205,270MBH

•155 MBH combi model available! –Best-in-classDHWperformance

• Field-proven,stainlesssteelfiretubeheatexchanger

• AdvancedSage2.2boilercontrolprovides “out-of-the-box”highperformanceandeasysetup –Ergonomicallyangledtouchscreendisplay simplifiesinstallation,operation,anddiagnostics –Easilyconnectstooptional Sage Zone Control foradditionalenergy savings,system optimization,and“short cycle”prevention

• Highaltitude–zeroorminimalde-ratings, reducesthecostsofoversizing,fieldadjustable

• FULL SIZEeasyaccesssideservicepanel

VALUABLE EXTRAS INCLUDED

• Versatile top and bottom connections for supply & return (on heating-only boilers)

• UniversalventconnectionforCPVC/PVC, polypropylene

• Split-voltagejunctionbox,fusedeasy-connect terminals

• Outdoorresetandsensor(wired)• Piped&wiredforlowwatercutoffinstallation (probenotincluded)

• 5-yearpartswarranty

ANYWHEREUNMATCHED

ANYWHEREUNMATCHED

High Efficiency, Gas Fired, Stainless Steel, Condensing Boiler

COMBI AVAILABLE!

MADE IN U.S.A.

Page 2: High Efficiency, Gas Fired, Stainless Steel, Condensing Boiler Product Data Sheet.pdf• 155 MBH combi model available! – Best-in-class DHW performance • Field-proven, stainless

©2016U.S.BoilerCompany,Inc.Lancaster,PAPhone:1-888-432-8887

FormNo.USBL16020120m6/16

www.usboiler.net

K2 Firetube: Technical InformationK2FT Ratings & Specifications

Model AFUE%

Input(MBH)

min-max

DOE HeatingCapacity(MBH)

Net AHRI

(MBH)MAWP(PSI)

Vent Size

(Inches)

Approx. Shipping Weight (lbs.)

K2FT-085 95.0 17-85 79 69 30 2or3 140K2FT-110 95.0 22-110 102 89 30 2or3 145K2FT-155 95.0 31-155 145 126 30 3 160K2FT-205 95.0 41-205 190 165 80 3 175

K2FT-270 95.0 54-270 251 218 80 3 185COMBIMODEL*

K2FTC-155 95.0 31-155 145 126 30 3 170

Standard Equipment • Directvent,sealedcombustionappliance• 5:1turndown• NaturalorLPgas,fieldconvertible• Stainlesssteelheatexchanger,firetube• Easyaccesscontrolpanel• Separated,fusedhighandlowvoltageconnections• Sage2.2ControlSystem –LCDtouchscreendisplay,angled –Self-guidedcontrolmenus –Built-inselfdiagnostics –(3)Circulatoroutputsavailable –Built-insequencer,stagesupto(8)boilers –Outdoorresetincludingoutsidesensor –DHWpriority –Warmweathershutdown –Modbuscommunications –Passwordsecurity• Variablespeedcombustionblower• Gasvalve• Polypropylenecondensatetrap• LWCO-readyNPTconnection• Supply,return,andautoresethighlimitwatersensors• Universalventconnection(CPVC/PVC,PP)• Fluegastemperaturesensoranddifferentialpressureswitch• 30PSIsafetyreliefvalve• Pre-installedhangingbracketandwallmountkit• Fieldadjustableforhighaltitudewithminimalderate• Thermostatic DHW mixing valve(K2FTC-155combionly)

SafetyReliefValvePressure,Water–30PSIstd.ASMEcertified“H”.Maxallowabletemperaturesetting210ºF.Targetsetpointis180°F,manualresethighlimitsetpointis210°F.Boilersshippedsetfornaturalgas.Aboveperformanceisforelevationsto2000’.Consultmanualforinstructionsandperformanceforinstallationsupto10,100’.Allowableventlengthsupto135ft.

Typical Venting Configurations (Horizontal and Vertical)

Horizontal2-pipelowprofile

Horizontal2-pipeconcentric

Illustrationsareforrepresentationonly.Forcompleteventinginformation,pleaseseeInstallationmanual.

Vertical2-pipe

Vertical2-pipeconcentric

Horizontal2-pipe

Hybrid

Verticalexhaust/sealedB-ventforcombustionair

*DHWflowrateofoptionalcombi-equippedmodelK2FTC-155is4.0GPM@70°TR

Accessories:• SageZoneControl(P/N:104590-01)• Wirelessadapteroutdoorreset(PN:105121-01)• LWCOkit(P/N:100592-01or105591-01)• Servicepartsrepairkit(P/N:107118-01)• Kit,CPVCstarterandPVCventterminations: (2”P/N:107039-01)(3”P/N:107039-02)

Control Access Panel

33-5/16”Gas Connection1/2”

CondensateConnection

Condensate Trap Cleanout

Drain Valve

VentConnection

Relief Valve

Air IntakeConnection

Temperature/Pressure

Gauge

Alternate Return/InletWater Connection

(heating-only models)

ServiceAccess

Panel

AlternateSupply/Outlet

Water Connection(heating-only models)

Return/Inlet Water

Connection1”

Supply/OutletWater Connection - 1”

Outsideof Wall

Insideof Wall

19-13/16”

A

Dimensions (Inches)

Model A

K2FT-085 20

K2FT-110 20

K2FT-155 20

K2FT-205 21

K2FT-270 21

K2FTC-155 23

ASM

E

H