High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

21
High Density BSC & BSC/TRC ETSI/ANSI for GSM Product Package Description 221 03-FAP 130 0516 Uen Rev T

Transcript of High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

Page 1: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

for GSM

Product Package Description

221 03-FAP 130 0516 Uen Rev T

Page 2: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

2 (21)

No part of this document may be reproduced in any form without the written permission of the copyright owner. The contents of this document are subject to revision without notice due to continued progress in methodology, design and manufacturing. Ericsson shall have no liability for any error or damage of any kind resulting from the use of this document. The information provided in this document concerning capacity, suitability and performance shall not be considered commercially binding. Please note that all capacity figures and dimensioning methods are based on Ericsson’s own models of how subscribers behave in a network. The document is intended to be used by professionally trained personnel. It is strongly recommended to involve Ericsson in discussions covering the contents of this document. Any feedback that may help Ericsson improve the documentation and information methods is welcome.

Page 3: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

3 (21)

Contents

1 General ................................................................................................... 4 1.1 Purpose ................................................................................................... 4 1.2 Changes since last release of this document .......................................... 4 1.3 Commercial Product Numbers................................................................. 4 1.4 Base Configurations ................................................................................ 5 1.5 Options .................................................................................................... 7 1.6 Expansions ............................................................................................ 13

2 Cabinet Allocation and Floorplan ...................................................... 14 2.1 Cabinet Allocations................................................................................ 14 2.2 Standard Floorplan ................................................................................ 16

A Node Related Site Products ............................................................... 17 A.1 Basic Mechanics.................................................................................... 17 A.2 AXE Operation and Maintenance, O&M................................................ 17 A.3 External Cables ..................................................................................... 18

B Site Related Site Products.................................................................. 19

C Glossary ............................................................................................... 20

Page 4: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

4 (21)

1 General

1.1 Purpose

The purpose of this document is to describe the Product Package for the High Density BSC & BSC/TRC ETSI/ANSI within GSM for 07B and later SW releases. This Product Package Description (PPD) covers: New Nodes Expansions Reuse of GDM hardware

This document also provides the following details: Estimated Capacity, Functionality, Allocation drawings, Floorplan and the estimated Maximum power consumption and number of fuses of the included cabinets.

1.2 Changes since last release of this document Chapter 1.4, 2.1.1 and 2.1.2, number of fuses reduced and fuse size updated. Chapter 1.4 and 1.6.4, SLI option added. Chapter 1.5.9, text about AGW and PGW ordering added. Chapter 1.5.7, Re-use subrack option added. DLEB and GESB option

included in this one.

1.3 Commercial Product Numbers

Commercial Product Numbers are the priced items in the commercial sales tools that correspond to the defined Base Configurations and the Optional Functionalities.

Commercial Product Numbers does, as opposed to Discrete Orderable Product Numbers, not contain the deliverable items and should not be used for ordering.

Page 5: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

5 (21)

1.4 Base Configurations

To order capacity higher than 2048 TRX an optional package in chapter 1.5.2 have to be added to Base Configuration 2048.

Characteristics Base Configurations

Node type BSC

Base Configurations

256 512 768 1024 1280 1536 1792 2048

INF903 0147 APZ 212 55

/9 /1 /2 /3 /4 /5 /6 /7

APG 43/2 1 1 1 1 1 1 1 1

TRHB boards 1 2 3 4 5 6 7 8

Capacity (TRX) 256 512 768 1024 1280 1536 1792 2048

STM-1 (E1)

1 (63)

1 (63)

2 (126)

2 (126)

3 (189)

4 (252)

4 (252)

6 (378)

OC-3 (T1)

1 (84)

1 (84)

2 (168

2 (168)

3 (252)

4 (336)

4 (336)

6 (504)

Transcoder Channels - - - - - - - -

Cabinets within Base Configuration

1 1 1 1 1 1 1 2

Power for Base Configuration (kW)

0.9 0.95 1 1.05 1.1 1.15 1.2 1.7

Total Number of 30A + 15A Fuses

6+6 6+6 6+6 6+6 6+6 6+6 6+6 12+12

Footprint (m2) 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.48

For further details see ‘BSC/TRC and BSC Hardware Dimensioning Handbook’, document number 1555-AXE 105 07.

The number of TRHB boards decides the TRX capacity. Heavy TRH traffic per TRX and heavy paging load may limit the number of TRXs per TRHB.

For signaling SS7/C7, HSL or SLI can be selected. No signaling boards are included in the Base configurations so a choice has to be made to include signaling in the order. It's possible to order both SS7/C7, HSL and SLI in the same node. Option Pack Commercial product number Base 1 2

SS7/C7 INF 903 0152/1 (1 redundant SS7/C7 over TDM link) 0 1+1 2+2

Option Pack Commercial product number Base 1 2

HSL INF 903 0152/1 (1 redundant HSL over TDM link) 0 1+1 2+2

Option Pack Commercial product number Base 1 2

SLI INF 903 0127 (1 redundant SS7 over IP link) 0 1+1 2+2

Page 6: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

6 (21)

To order capacity higher than 2048 TRX an optional package in chapter 1.5.2 have to be added to Base Configuration 2048.

Characteristics Base Configurations

Node type BSC/TRC TRC

Base Configurations

256 512 768 1024 1280 1536 1792 2048 -

INF903 0148 APZ 212 55

/9 /1 /2 /3 /4 /5 /6 /7 INF903 0151/1

APG 43/2 1 1 1 1 1 1 1 1 1

TRHB boards 1 2 3 4 5 6 7 8 0

Capacity (TRX) 256 512 768 1024 1280 1536 1792 2048

STM-1 (E1)

1 (63)

1 (63)

2 (126)

3 (189)

4 (252)

4 (252)

4 (252)

6 (378)

3 (189)

OC-3 (T1)

1 (84)

1 (84)

2 (168

3 (252)

4 (336)

4 (336)

4 (336)

6 (504)

3 (252)

Transcoder Channels 384 768 1536 2304 3072 3840 4608 5376 3840

Transcoder Capacity ERLANG (0,1% GoS)

338 706 1450 2200 2960 3720 4480 5240 3720

Cabinets within Base Configuration

1 1 1 1 1 1 1 2 1

Power for Base Configuration (kW)

0.9 1 1.1 1.2 1.3 1.4 1.5 2 1.3

Total Number of 30A + 15A Fuses

6+6 6+6 6+6 6+6 6+6 6+6 6+6 12+12 6+6

Footprint 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.48 0.24

For further details see ‘BSC/TRC and BSC Hardware Dimensioning Handbook’, document number 1555-AXE 105 07.

The number of TRHB boards decides the TRX capacity. Heavy TRH traffic per TRX and heavy paging load may limit the number of TRXs per TRHB.

For signaling SS7/C7, HSL or SLI can be selected. No signaling boards are included in the Base configurations so a choice has to be made to include signaling in the order. It's possible to order both SS7/C7, HSL and SLI in the same node. Option Pack Commercial product number Base 1 2

SS7/C7 INF 903 0152/1 (1 redundant SS7/C7 over TDM link) 0 1+1 2+2

Option Pack Commercial product number Base 1 2

HSL INF 903 0152/1 (1 redundant HSL over TDM link) 0 1+1 2+2

Option Pack Commercial product number Base 1 2

SLI INF 903 0127 (1 redundant SS7 over IP link) 0 1+1 2+2

Page 7: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

7 (21)

1.5 Options

In addition to the base configurations, option packs can be added to a Product Package configuration. Maximum capacity of all option packs is not possible. The group switch is the limiting factor and allows for 8 eGEM subracks to be used for base configuration and option packs. The eGEM with APZ 212 55 and APG43/2 is not included in this number.

1.5.1 Redundant TRHB

Option Pack Commercial product number Base 1

Redundant TRHB INF 903 0155/1 (256 TRX) 0 1

1.5.2 TRHB

Option Pack Commercial product number Base 1 2 3

TRHB INF 903 0155/1 (256 TRX) 2048 (8)

2304 (9)

2560 (10)

2816 (11)

4 5 6 7 8

3072 (12)

3328 (13)

3584 (14)

3840 (15)

4095 (16)

The feature ‘Support for 4000 TRXs per BSC’ is required for option pack 1-8.

1.5.3 PCU

Option Pack Commercial product number Base 1

# of 16 kbit/s GSL channels INF 903 0154/1 (512 GSL channels) 0 512

(256)

2 3 4 5 6 7 8 9 10 11 12

1024 (512)

1536 (768)

2048 (1024)

2560(1280)

3072(1536)

3584(1792)

4096(2048)

4608(2304)

5120 (2560)

5632 (2816)

6144 (3072)

13 14 15 16 17 18 19 20 21 22 23

6656 (3328)

7168 (3584)

7680 (3840)

8192(4096)

8704(4352)

9216(4608)

9728(4864)

10240(5120)

10752 (5376)

11264 (5632)

11776(5888)

24 25 26 27 28 29 30 31 32

12288 (6144)

12800 (6400)

13312 (6656)

13824(6912)

14336(7168)

14848(7424)

15360(7680)

15872(7936)

16384 (8192)

The number within brackets is the capacity of 64kbit GSL channels for EGPRS or CS-3/CS-4.

Page 8: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

8 (21)

1.5.4 STM-1/OC-3

Option Pack Commercial product number Base

STM-1/OC-3 channels INF 903 0014/1 (1 redundant STM-1 link) 1

2 3 4 5 6 7 8 9

2 (126/168)

3 (189/252)

4 (252/336)

5 (315/420)

6 (378/504)

7 (441/588)

8 (504/672)

9 (567/756)

10 11 12 13 14 15 16

10 (630/840)

11 (693/924)

12 (756/1008)

13 (819/1092)

14 (882/1176)

15 (945/1260)

16 (1008/1344)

1.5.5 Transcoder channels

Option Pack Commercial product number Base

Transcoder channels INF 903 0013/2 (384 TRA channels) 0

1 2 3 4 5 6 7 8 9

384 (338)

768 (706)

1152 (1078)

1536 (1453)

1920 (1829)

2304(2206)

2688 (2584)

3072 (2963)

3456 (3342)

10 11 12 13 14 15 16 17 18

3840 (3720)

4224 (4100)

4608 (4480)

4992 (4861)

5376 (5240)

5760(5622)

6144 (6003)

6528 (6383)

6912 (6764)

19 20 21 22 23 24 25 26 27

7296 (7145)

7680 (7530)

8064 (7908)

8448 (8290)

8832 (8671)

9216(9053)

9600 (9434)

9984 (9816)

10368 (10198)

28 29 30 31 32 33 34 35 36

10752 (10580)

11136 (10962)

11520 (11344)

11904 (11726)

12288 (12108)

12672(12490)

13056 (12872)

13440 (13254)

13824 (13636)

37 38 39 40 41 42 43 44 45

14208 (14019)

14592 (14401)

14976 (14784)

15360 (15166)

15744 (15549)

16128(15931)

16512 (16314)

16896 (16696)

17280 (17079)

46 47 48

17664 (17461)

18048 (17844)

18432 (18227)

The numbers within brackets are transcoder capacity in Erlang with 0,1% GoS. The Erlang values assume all transcoders are in the same transcoder pool.

1.5.6 NWI-E

Option Pack Commercial product number Base 1

BSC NWI-E (Network Interface - Ethernet)

INF 903 0399/1 (1 NWI-E with redundancy) 0 1+1

Page 9: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

9 (21)

1.5.7 Re-use subrack

Option Pack Commercial product number Base 1

GESB INF 903 0455 (1+1 GESB boards) 0 1+1

DLEB INF 903 047/1 (1+1 DLEB boards) 0 2+2

Serial RP bus interfaces (4 pairs) INF 903 0086/1 0 2

This option allows for GDM hardware to be reused in the node. DLEB and serial RP-bus is always needed and GESB if PCU on RPP is reused. The GESB and DLEB boards will always be delivered in an EGEM subrack. The ordering tool will allow for ET155 expansion in this subrack.

1.5.8 Time of day

Option Pack Commercial product number Base 1 2

ToD INF 903 0454/1 (Time of Day, NTP Client ) 0 1 2

Option 1 will give 1 board for ToD. Option 2 will provide redundancy.

Page 10: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

10 (21)

1.5.9 AGW/PGW improvement

AGW and PGW have a limitation in the ordering model due to MUP consumption. A total of 8 per subrack of any combination of AGW and PGW is possible. This makes it sometimes hard to order needed quantity since the ordering model requires that the last subrack is filled up with boards before the next subrack is allocated. We now introduce an option called ‘Reserved pos’ to increase the quantities to be available for AGW and PGW. ‘Reserved pos’ is a work around that allows a subrack to be filled up with ‘Dummy boards’ and a new subrack to be allocated. If you for example only have the option to add 12 PGW and you want 16 you should look in the option ‘Reserved pos’ and select 8 and you will find that for PGW you now have the possibility to order up to 20 boards.

The downside is that FAP 130 0516 doesn’t allow for the dummy boards selected with option ‘Reserved pos’ to be substituted for any other board in the future. Once a slot have been occupied with a dummy board selected with option ‘Reserved pos’ this allocation have to be remembered and the quantity have to be added for the option ‘Present number of Reserved pos’ in future expansions. The Dummy board generated with the question ‘Reserved pos’ is the same as the other Dummy boards in the node so it is not possible to find out number of ‘Reserved pos’ selected by calculating Dummy boards in a node.

The number of ‘Reserved pos’ selected have to be tracked by the ordering office. The information will be available in document "193 26-IPB number" for the node. In reality this will be a short term extra work. AGW orders will be more common than PGW and when AGW is implemented the TRA functionality is removed from the BSC/TRC and the node transform to a remote BSC. The CSPB 2.0 boards can now be removed and replaced with any other boards. When this happens FAP 130 0516 can no longer be used for expansion of the node and the ordering office should use the pick list in FAP 130 2171 for all future orders.

1.5.10 AGW

Option Pack Commercial product number Base 1 2 3

BSC AGW INF 903 0401/1 (900 SCC) 0 900 1800 2700

4 5 6 7 8 9 10 11 12 13

3600 4500 5400 6300 7200 8100 9000 9900 10800 11700

14 15 16 17 18 19 20 21

12600 13500 14400 15300 16200 17100 18000 18900

Page 11: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

11 (21)

1.5.11 PGW

Option Pack Commercial product number Base

PGW boards INF 903 0400/1 (1 PGW/2 board) 0

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

11 12 13 14 15 16 17 18 19 20

11 12 13 14 15 16 17 18 19 20

21 22 23 24 25 26 27 28 29 30

21 22 23 24 25 26 27 28 29 30

31 32 33 34 35 36 37 38 39 40

31 32 33 34 35 36 37 38 39 40

The capacity on each PGW/2 board is dependent on the traffic model and if A-bis opt or A-bis over IP with A-bis opt is used.

1.5.12 Site Products

Site products contain equipment related to the installation of the node. Site products is divided in Node Related Site Products (NRSP), see Appendix A, and Site Related Site Products (SRSP), see Appendix B.

Page 12: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

12 (21)

1.5.13 Network Synchronization

The BSC can be provided with Network Synchronization (NS) references in a number of ways:

If the Reference Timing for NS is taken from an SDH network then Synchronization can be provided via the ET155 hardware

If the Reference Timing for NS is taken from a PDH network terminated in ETC devices then Synchronization can be provided via the CSM (or ET4-1).

If a Primary Reference Clock (PRC) like a Central Building Clock (CBC) exists at the switch facility, then Reference Timing for NS can be taken from there (ordered as SRSP).

If CSM (or ET4-1) is used to adapt the node to a PDH network environment, Reference Timing for NS over PDH can be distributed via CSM (or ET4-1) in the outgoing and incoming direction from the node.

The Network Synchronization planning shall recommend the best solution for the node, considering all the network implications and dependencies.

note: ET4-1 is an old product replaced by CSM.

1.5.14 Customer Product Information

All necessary supporting documentation can be found in the CPI Store. The documents can be downloaded or ordered on CD-ROM.

1.5.15 Optional Spares

To support the node, spare part management (available in HW Support service from Ericsson’s Global Services portfolio) is recommended. Alternatively, Spare Part Sale of single items is available. Please contact local Ericsson personnel for more information.

Page 13: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

13 (21)

1.6 Expansions

All options are also available as expansions. Maximum capacity of all option packs is not possible. The group switch is the limiting factor and allows for 8 eGEM subracks to be used for base configuration and option packs. The eGEM with APZ 212 55 and APG43/2 is not included in this number.

1.6.1 TRHB

Option Pack Commercial product number Base 1 2

TRHB INF 903 0155/1 (256 TRX) 256 (1)

512 (2)

768 (3)

3 4 5 6 7 8 9 10

1024 (4)

1280 (5)

1536 (6)

1792 (7)

2048 (8)

2304 (9)

2560 (10)

2816 (11)

11 12 13 14 15 16

3072 (12)

3328 (13)

3584 (14)

3840 (15)

4095 (16)

4095 (17)

The feature ‘Support for 4000 TRXs per BSC’ is required for option pack 8-15. Option pack 16 is the redundant board for nodes expanded to 4095 TRX.

1.6.2 SS7/C7

Option Pack Commercial product number Base 1 2

SS7/C7 INF 903 0152/1 (1 redundant SS7/C7 over TDM link) 0 1+1 2+2

1.6.3 HSL

Option Pack Commercial product number Base 1 2

HSL INF 903 0152/1 (1 redundant HSL over TDM link) 0 1+1 2+2

1.6.4 SLI

Option Pack Commercial product number Base 1 2

SLI INF 903 0127 (1 redundant SS7 over IP link) 0 1+1 2+2

Page 14: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

14 (21)

2 Cabinet Allocation and Floorplan The following section describes the equipment practice, cabinet allocations and the standard floorplan.

2.1 Cabinet Allocations

All HW is housed in BYB 501 cabinets. The cabinet dimensions (H x W x D) are 1800x600x400 mm.

All internal cables in BYB 501 cabinets are halogen free and self-extinguishing.

Plenum Cables are available as an option.

2.1.1 Mandatory eGEM cabinet

1500W 12 Fuses 140 kg

eGEM Cabinet

eGEM

Dynamically configured eGEM subracks

APZ 212 55 & APG 43/2

eGEM

APZ 212 55 & APG 43/2

Page 15: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

15 (21)

2.1.2 Optional eGEM cabinet

1700W 12 Fuses 140 kg

eGEM Cabinet

eGEM

Dynamically configured eGEM subrackseGEM

eGEM

Page 16: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

16 (21)

2.2 Standard Floorplan

Note that there has to be at least 800mm of free space between a cabinet front or back with doors and the nearest wall.

1800mm

800mm

800mm

800mm

1200mm 300 mm

Mandatory eGEM

BSC DataCom Cabinet

Double Row floor plan. This is the prefered floorplan layout. Cabinets and corresponding engineering related documentation supports this floor layout.

Optional eGEM

Optional eGEM

1800mm

800mm

400mm

1200mm 300 mm

MandatoryeGEM

Single Row floor plan. The Product Package generated for a single-row floor plan will contain a C-module that supports back-to-back layout. If single-row is requested the C-module has to be created locally.

Optional eGEM

Optional eGEM

2400mm

800mm

800mm

1200mm 300 mm

800mm

Two BSC´s back-to-back.

Minimum aisle width required for maintenance activities

300mm Minimum clearance from walls in Earthquake Zones

Cabinets mandatory in all configurations.

Cabinet positions used depending on chosen configuration.

BSC DataCom Cabinet Mandatory

eGEM

Mandatory eGEM

Optional eGEM

Optional eGEM

Optional eGEM

Optional eGEM

BSC, BSC/TRC and TRC nodes must be configured according to one of the floor plans as indicated above. Double row is the preferred method. Cabinets and corresponding engineering related documentation does only support this layout.

Page 17: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

17 (21)

Appendices

A Node Related Site Products Node Related Site Products (NRSP) is related to a specific node and are configured, ordered and delivered together with the node.

A.1 Basic Mechanics

For All BYB 501 Cabinets the following options for mechanics are available.

Mechanics Description

Ericsson overhead mechanics based on wire trays.

The kits include overhead mechanics, cover plates for all sides of the OH-mechanics, side plates for cabinet and mechanics for the cabinet door.

No overhead mechanics (usage of Raised Floor or non-Ericsson overhead mechanics)

Side plates for cabinet and mechanics for the cabinet door.

Table 1 – Basic Mechanics

It is mandatory to choose one of the mechanics packages.

A.2 AXE Operation and Maintenance, O&M

Option

Range Description Price Object

Include Alarm Display Yes/No Alarm Display for APG40, APG43 or APG43/2

FAH 107 725/2

External Alarm to DF Yes/No Alarm Cable to DF INF 901 3566/1

Table 2 – AXE O&M

Page 18: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

18 (21)

A.3 External Cables

External cables are used for connecting the node to ODF/DDF/DSX equipment, node to node directly or to the power system.

Cable GARP to Ethernet provides Ethernet connection possibility from GARP for applications requiring Ethernet connections.

Price Object Description

Option

Straight Crossed

Information for Proposal

model

15 m FAH 107 200/1 FAH 107 200/3 Not included

30 m FAH 107 200/2 FAH 107 200/4 Not included

45 m FAH 107 200/31 FAH 107 200/33 Not included

Cable Type Fast Ethernet

60 m FAH 107 200/32 FAH 107 200/34 Not included

Price Object Description

Option

SC-FC/PC SC-E2000 SC-SC

Information for Proposal

model

15 m FAH 107 048/7 FAH 107 048/13 FAH 107 048/1 Not included

20 m FAH 107 048/25 FAH 107 048/27 FAH 107 048/23 Not included

25 m FAH 107 048/26 FAH 107 048/28 FAH 107 048/24 Not included

30 m FAH 107 048/8 FAH 107 048/14 FAH 107 048/2 Not included

45 m FAH 107 048/9 FAH 107 048/15 FAH 107 048/3 Not included

60 m FAH 107 048/10 FAH 107 048/16 FAH 107 048/6 Not included

75 m FAH 107 048/11 FAH 107 048/17 FAH 107 048/4 Not included

Opto cable Connector

STM-1/OC-3 Optical Fibre (For fibre cable, single mode)

100 m FAH 107 048/12 FAH 107 048/18 FAH 107 048/5 Not included

Power cable length Power Cable 10 m-70 m in steps of 5 m

INF 901 2560/1

(price per meter)

Default 30 M (x number of distributions)

Positive strengthening and earthing cable

No option (50 m always included) Included in base configuration

Table 3 – External Cables

Note: External plenum cables should be sourced locally. Due to the need of connectors on the power cables when the EPDU (Enclosed Power Distribution Unit) is used the power cables shall be ordered in the EPDU PP.

Page 19: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

19 (21)

B Site Related Site Products The Site Related Site Products (SRSP) does not relate to a specific node but are common for several nodes on the same site. SRSP are included in separate product packages and should also be configured, ordered, delivered and priced separately.

Please refer to respective see Product Package Description/Ordering Guide for further details: Products Description Product Package

221 03-FAP 130 0258

2135-FAP 130 896 Power Supply

Power systems are available for high-ohmic distribution (HOD) and low-ohmic distribution (LOD):

ACTURA 48701 HOD/LOD max 86kW, Emerson ACTURA FLEX 48300 HOD max 30kW, Emerson Compact/Modular HOD/LOD max 40 kW, Power One 2135-FAP 130 0178

Power Distribution

The Enclosed Power Distribution Unit (EPDU) is a system for conversion of LOD to HOD for –48V DC power. Intended for use where a power plant with LOD provides DC power to HOD equipment, such as AXE.

221 03-FAP 130 824

Inverters Inverters are available in Small, Medium and Large configurations.

221 03-FAP 130 0259

AXE Operation and Maintenance (O&M)

AXE O&M equipment includes products from IO to terminal end equipment, for example LAN kit, extra alarm displays, inverter kit, WinFIOL and tools licenses.

221 03-2/FAB 102 616

IP RAN

Ericsson’s complete e2e IP RAN consists of the following product and solution components: -GSM, WCDMA, LTE IP RAN, -Mobile backhaul (MBH), -IP RAN Reference solution, -Site Integration Unit (SIU), -OSS

Mobile PBN

The Mobile PBN design describes inter-site backbone connectivity and intra-site connectivity design for all Core Network CS and PS nodes, MSC’s, GSN’s, MGw's, etc. M-PBN also includes the connectivity of these nodes to internal and external networks.

Distribution Frames The Distribution Frames (DF) package consists of Digital DF (DDF), Optical DF (ODF), Flexfield and Main DF (MDF).

221 03-2/FAB 102 615

Raised Floor Raised floor is generally recommended by Ericsson and must be used when under floor cabling is chosen.

External Mechanics External mechanics are used for cabling between the node and other site elements.

Earthquake Reinforcements

Earthquake reinforcement contains earthquake frames with mounting set for raised floor or for concrete floor.

221 03-2/FAB 102 667

Network Synchronization

(GPS Clock)

The GPS Synchronization Clock works as a primary reference clock and provides Network Synchronization and Time of Day. The GPS Synchronization Clock product is housed in a BYB 501 cabinet and includes a GPS antenna.

221 03-2/FAB 102 792

DataCom cabinet The DataCom cabinet (double deep BYB 501) is adjusted to have more space for DataCom equipment that requires side-to-side airflow.

221 03-FAP 130 710

Table 4 – SRSP equipment Note: Some of the Site Related Site Products are not available in the ANSI market. Please contact Ericsson local representative for more details.

Page 20: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

20 (21)

C Glossary

A Interface between BSC and M-MGw or MSC

A-bis Interface between BSC and BTS in GSM systems

AGW A-interface Gateway AMR F-R Adaptive Multi Rate Full Rate AMR H-R Adaptive Multi Rate Half Rate ANSI American National Standards

Institute APG Adjunct Processor Group APT The telephone part of the AXE

switching system APZ The control/computer part of the

AXE switching system A-ter Interface between BSC and TRC

in GSM systems ATM Asynchronous Transfer Mode AXE Ericsson’s main platform for

telecommunication nodes AXE810 The current release of AXE BSC Base Station Controller BYB501 AXE building practice CPI Customer Product Information C7 CCITT No.7 CBC Central Building Clock CS Circuit Switch DC Direct Current DDF Digital Distribution Frame DS Data Store E 1. Erlang

2. Ethernet E1 Lowest level PDH ETSI standard

(2.048 Mb/s) EDGE Enhanced Data rates for Global

Evolution EEC European Economic Community EFR Enhanced Full Rate speech

codec EGEM Enhanced Generic Ericsson

Magazine EGPRS Enhanced General Packet Radio

Service EMC Electromagnetic Compatibility ET Exchange Terminal ET4-1 Multiplexor for ET155

ETSI European Telecommunications Standards Institute

EU European Union FE Fast Ethernet FR Full rate GARP-1 Generic Application Resource

Platform 1 Gb Interface between BSC-PCU and

SGSN-G (or “Interface between an SGSN and a BSS”?)

GE Gigabit Ethernet GEM Generic Ericsson Magazine GGSN Gateway GPRS Support Node GoS Grade of Service GPHB GPRS Packet Handler Board GPRS General Packet Radio Service GPS Global Positioning System GRAN Generic Radio Access Network GSC GPS System Clock GSL GPRS Signalling Link GSM Global system for Mobile

Communication GSN GPRS Support Node GW Giga Word HDLC High level Data Link Control HOD High Ohmic Distribution HSL High Speed Signaling Link HR Half Rate HW Hard Ware I/O Input / Output IP Internet Protocol ITU-T International

Telecommunications Union - Telecommunications

K kilo Kbit/s kilobit per second LAN Local Area Network LAPD Link Access Procedure Direct Lb Interface between SMPC and

BSC or BSC/TRC in GSM systems

LOD Low Ohmic Distribution

Page 21: High Density Bsc and Bsc-trc Etsi-Ansi 221 03-Fap 130 0516 Rev t

High Density BSC & BSC/TRC ETSI/ANSI

221 03-FAP 130 0516 Uen Rev T 2011-02-17 Ericsson AB 2010 Commercial in confidence

21 (21)

M Mega Mbps Megabits per second MDF Main distribution frame MSC Mobile Services Switching Centre MW Mega Word m meter NRSP Node Related Site Products NS Network Synchronization O&M Operation and Maintenance OC-3 Optical Carrier level 3 ODF Optical Distribution Frame OMT Operation and Maintenance

Terminal OSS-RC Operations Support System for

Radio and Core p pair PBN Packet Backbone Network PCU Packet Control Unit PDH Plesiochronous Digital Hierarchy PGWB Packet Gateway Board PP Product Package PPD Product Package Description PRA Primary Rate Access PRC Primary Reference Clock PS Program Store RBS Radio base station RPB-S Regional Processor Bus - Serial RPG Regional Processor with Group

Switch Interface RPP Regional Processor with PCI

interface RS Reference Store RTU Right To Use

SCC Simultaneous call capacity SDH Synchronous Digital Hierarchy SISC SERCnet Implementors Sub-

Committee SGSN Serving GPRS Support Node SLI SIGTRAN Link Interface SMPC Serving Mobile Positioning Center SRSP Site Related Site Products SS7 Signaling System #7 SSH Source System Handling STC Signaling Terminal Control STEB Signaling Terminal Enhanced

Board STM Synchronous Transfer Mode STM-1 Fundamental SDH level with

155.52Mbps STOC Signaling Terminal for Open Communications SW Software T1 Lowest level PDH ANSI standard

(1.5 Mb/s) TEMS TEMSTM Optimization Solutions TFO Tandem Free Operation TRA Transcoder Rate Adapter TRC Transcoder & Rate Adapter

Controller TRHB TRansceiver Handler Board TRX Transceiver UM Universal mobile VC Voice Channel VDC Volts of Direct Current VA Volt Ampere W Watt