19 Part Number Encoding Figure 3.3 identifies the significance of each character in the HarmonicGuard Active filter part number. An example of a completed part number would be ALC100A01H2000. This designates an enclosed HarmonicGuard Active filter that is rated for 100 amps, 480 volts, and has an HMI Interface Module Package. HGA Part Numbering System – 480V Open and Type 1 Current: 45, 50, 90, 100, 200 Voltage: 480 Enclosure: Open Chassis or UL Type 1 Figure 3.3 – HarmonicGuard Active filter part number encoding ALC 100 A 01 H 00 XX ALC prefix Current Rating Voltage Rating A= 480 Enclosure 00 = Open Chassis 01 = UL Type 1 Package Option Circuit Breaker H=Interface Module 10=ABB 22kA 20=ABB 100kA 30=A-B 25kA 40=A-B 65kA, 60=Eaton 65kA 70=Eaton 100kA, 80=Square D 18kA 90=Square D 65kA, 00=No breaker 01=ABB 65kA Reserved for custom options to be defined as needed, each position can use 0 thru 9 45, 50, 90, 100, 200 Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

Transcript of HGA Part Numbering System – 480V Open and Type 1 00=No ... · HGA Ordering Instructions - HMI...

Page 1: HGA Part Numbering System – 480V Open and Type 1 00=No ... · HGA Ordering Instructions - HMI Revision A Page 12 January 1, 2015 Product & Price Guide Phone: 414-357-4480 Fax: 414-357-4484

19

Part Number Encoding Figure 3.3 identifies the significance of each character in the HarmonicGuard Active filter part number. An example of a completed part number would be ALC100A01H2000. This designates an enclosed HarmonicGuard Active filter that is rated for 100 amps, 480 volts, and has an HMI Interface Module Package.

HGA Part Numbering System – 480V Open and Type 1 Current: 45, 50, 90, 100, 200 Voltage: 480 Enclosure: Open Chassis or UL Type 1

Figure 3.3 – HarmonicGuard Active filter part number encoding

ALC 100 A 01 H 00 XX

ALC prefix

Current Rating

Voltage Rating

A= 480

Enclosure

00 = Open Chassis

01 = UL Type 1

Package Option

Circuit Breaker

H=Interface Module

10=ABB 22kA 20=ABB 100kA 30=A-B 25kA 40=A-B 65kA, 60=Eaton 65kA 70=Eaton 100kA, 80=Square D 18kA 90=Square D 65kA, 00=No breaker 01=ABB 65kA

Reserved for custom options to be defined as needed, each position can use 0 thru 9

45, 50, 90, 100, 200

Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]

JLNERI
Text Box
Cross Reference RA Part Number PN-307050
JLNERI
Red_Pointed_Right
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Text Box
JLNERI
Typewritten Text
ALC 50 A 00 H 0010
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
Page 2: HGA Part Numbering System – 480V Open and Type 1 00=No ... · HGA Ordering Instructions - HMI Revision A Page 12 January 1, 2015 Product & Price Guide Phone: 414-357-4480 Fax: 414-357-4484

HGA Ordering Instructions - HMI

Revision A

Page 12 January 1, 2015 Product & Price GuidePhone: 414-357-4480 Fax: 414-357-4484 www.transcoil.com

PART NUMBER TWO: HMI

Step 1) Based on the type of enclosure you are ordering, use one of the two Part Numbering Systems below to create your HMI part number:

• Figure 5: Open Chassis, UL Type 1 and UL Type 12• Figure 6: UL Type 3R

Step 2) Identify the required current, voltage and communication option to determine the second part number.

• Current RatingCorrective amp rating, see the HarmonicGuard Solution Center at www.transcoil.com/solutioncenter.htm

• Voltage RatingApplication voltage

• Communications Options - For Open Chassis, UL Type 1 and UL Type 12 the options include: ModBus RTU over RS485, Modbus TCP/IP, EtherNet I/P or DeviceNet (Figure 5)

- For UL Type 3R there is only one interface option which has no HMI display, but does have four status indicator lights, a run/stop key switch to control the unit and an external diagnostic port that an HGA-HMI unit, an optional addition, can be connected to (Figure 6). - The HGA-HMI is an HMI assembly inside a small portable case which can be ordered in addition to the required communication option. The part number to enter on your order is: HGA-HMI.

Figure 5: HMI Part Numbering System for Open Chassis, UL Type 1 and UL Type 12 units

Figure 6: HMI Part Numbering System for UL Type 3R units

CM 2 0 0 A R

HMI Part Numbering System: 3R

Current Rating

Voltage Rating A = 480C = 600 Type 3R

CM 2 0 0 A 0 1

HMI Part Numbering System

00 = Modbus® RTU over RS485

01 = EtherNet / IP & Modbus TCP/IP 02 = DeviceNet

Current Rating

Voltage Rating A = 480 C = 600 Communication Options

480V = 45, 50, 90, 100, 150, 200, 300600V = 039, 078

There is only one configuration of the HGA-HMI so there is only one part number for that which is HGA-HMI.

EtherNet/IP & Modbus TCI/IP are the same hard-

JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Highlight
JLNERI
Text Box
JLNERI
Typewritten Text
CM 0 5 0 A 0 1
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right
JLNERI
Red_Pointed_Right